Observium_CE/mibs/alpha/AlphaPowerSystem-MIB

2722 lines
86 KiB
Plaintext

AlphaPowerSystem-MIB DEFINITIONS ::= BEGIN
--==========================================================================
-- ALPHA.MIB
--
-- NOTE: Refer to RFC2578 for the formal definition of the SNMPv2-SMI MIB.
--
-- Changes:
-- September 23 2014
-- Added LPS alarms
--
-- February 22, 2011
--
-- Changed the property of Custom Signals to be Read and Write to
-- support SNMP Set feature.
--
-- June 03, 2010
--
-- Added inverter alarms.
--
-- January 25, 2010
--
-- Company name changed from Argus to Alpha.
-- All references changed accordingly.
--
-- November 3, 2008
--
-- The following new definitions were added:
-- Resync
-- Alarm Trigger
-- Time stamp
--
-- Subtyping removed from sequence definitions.
--==========================================================================
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC;
alpha MODULE-IDENTITY
LAST-UPDATED "201409230000Z"
ORGANIZATION "Alpha Technologies"
CONTACT-INFO
"Alpha Technologies
7700 Riverfront Gate
Burnaby, BC V5J 5M4
Canada
Tel: 1-604-436-5900
Fax: 1-604-436-1233"
DESCRIPTION
"This MIB defines the information block(s) available in system controllers
as defined by the following list:
- dcPwrSysDevice: Cordex series of Controllers"
::= { enterprises 7309 }
dcpower OBJECT IDENTIFIER ::= { alpha 4 }
dcPwrSysDevice OBJECT IDENTIFIER ::= { dcpower 1 }
dcPwrSysVariable OBJECT IDENTIFIER ::= { dcPwrSysDevice 1 }
dcPwrSysString OBJECT IDENTIFIER ::= { dcPwrSysDevice 2 }
dcPwrSysTraps OBJECT IDENTIFIER ::= { dcPwrSysDevice 3 }
dcPwrSysOutputsTbl OBJECT IDENTIFIER ::= { dcPwrSysDevice 4 }
dcPwrSysRelayTbl OBJECT IDENTIFIER ::= { dcPwrSysOutputsTbl 1 }
dcPwrSysAnalogOpTbl OBJECT IDENTIFIER ::= { dcPwrSysOutputsTbl 2 }
dcPwrSysAlrmsTbl OBJECT IDENTIFIER ::= { dcPwrSysDevice 5 }
dcPwrSysRectAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 1 }
dcPwrSysDigAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 2 }
dcPwrSysCurrAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 3 }
dcPwrSysVoltAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 4 }
dcPwrSysBattAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 5 }
dcPwrSysTempAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 6 }
dcPwrSysCustomAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 7 }
dcPwrSysMiscAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 8 }
dcPwrSysCtrlAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 9 }
dcPwrSysAdioAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 10 }
dcPwrSysConvAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 11 }
dcPwrSysInvAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 12 }
dcPwrSysLpsAlrmTbl OBJECT IDENTIFIER ::= { dcPwrSysAlrmsTbl 13 }
dcPwrSysInputsTbl OBJECT IDENTIFIER ::= { dcPwrSysDevice 6 }
dcPwrSysDigIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 1 }
dcPwrSysCntrlrIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 2 }
dcPwrSysRectIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 3 }
dcPwrSysCustomIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 4 }
dcPwrSysConvIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 5 }
dcPwrSysTimerIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 6 }
dcPwrSysCounterIpTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 7 }
dcPwrSysLpsTbl OBJECT IDENTIFIER ::= { dcPwrSysInputsTbl 8 }
dcPwrExternalControls OBJECT IDENTIFIER ::= { dcPwrSysDevice 8 }
dcPwrVarbindNameReference OBJECT IDENTIFIER ::= { dcPwrSysDevice 9 }
--==========================================================================
-- Start of variables
--==========================================================================
dcPwrSysChargeVolts OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value indicates the present battery voltage.
The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts."
::= { dcPwrSysVariable 1 }
dcPwrSysDischargeVolts OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value indicates the present load voltage.
The integer value represent a two digit fix decimal (Value = real voltage * 100) in Volts."
::= { dcPwrSysVariable 2 }
dcPwrSysChargeAmps OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value indicates the present battery currrent.
The integer value represent a two digit fix decimal (Value = real current * 100) in Amps."
::= { dcPwrSysVariable 3 }
dcPwrSysDischargeAmps OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value indicates the present load current.
The integer value represent a two digit fix decimal (Value = real current * 100) in Amps."
::= { dcPwrSysVariable 4 }
dcPwrSysMajorAlarm OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Major Alarm"
::= { dcPwrSysVariable 5 }
dcPwrSysMinorAlarm OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Minor Alarm"
::= { dcPwrSysVariable 6 }
--==========================================================================
-- Start of Strings
--==========================================================================
dcPwrSysSiteName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Site Name"
::= { dcPwrSysString 1 }
dcPwrSysSiteCity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Site City"
::= { dcPwrSysString 2 }
dcPwrSysSiteRegion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Site Region"
::= { dcPwrSysString 3 }
dcPwrSysSiteCountry OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Site Country"
::= { dcPwrSysString 4 }
dcPwrSysContactName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Contact Name"
::= { dcPwrSysString 5 }
dcPwrSysPhoneNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Phone Number"
::= { dcPwrSysString 6 }
dcPwrSysSiteNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Site Number"
::= { dcPwrSysString 7 }
dcPwrSysSystemType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of system being monitored by the agent."
::= { dcPwrSysString 8 }
dcPwrSysSystemSerial OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the monitored system."
::= { dcPwrSysString 9 }
dcPwrSysSystemNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of the monitored system."
::= { dcPwrSysString 10 }
dcPwrSysSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of software running on the monitored system."
::= { dcPwrSysString 11 }
dcPwrSysSoftwareTimestamp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time stamp of the software running on the monitored system."
::= { dcPwrSysString 12 }
--==========================================================================
-- Start of Tables Information
--==========================================================================
--=================
-- Output table
--=================
--========================
-- Relay output sub table
--=========================
dcPwrSysRelayCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of relay variables in system controller relay table."
::= { dcPwrSysRelayTbl 1 }
dcPwrSysRelayTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller rectifier relay output variables."
::= { dcPwrSysRelayTbl 2 }
dcPwrSysRelayEntry OBJECT-TYPE
SYNTAX DcPwrSysRelayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller relay output group."
INDEX { dcPwrSysRelayIndex }
::= { dcPwrSysRelayTable 1 }
DcPwrSysRelayEntry
::= SEQUENCE {
dcPwrSysRelayIndex INTEGER,
dcPwrSysRelayName DisplayString,
dcPwrSysRelayIntegerValue INTEGER,
dcPwrSysRelayStringValue DisplayString,
dcPwrSysRelaySeverity INTEGER
}
dcPwrSysRelayIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the relay variable in the power system controller relay output group."
::= { dcPwrSysRelayEntry 1 }
dcPwrSysRelayName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the relay variable as reported by the DC power system controller relay output group."
::= { dcPwrSysRelayEntry 2 }
dcPwrSysRelayIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the relay variable as reported by the DC power system controller relay output group."
::= { dcPwrSysRelayEntry 3 }
dcPwrSysRelayStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the relay variable as reported by the DC power system controller relay output group."
::= { dcPwrSysRelayEntry 4 }
dcPwrSysRelaySeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of relay severity level of the extra variable as reported by the DC power system controller relay output group."
::= { dcPwrSysRelayEntry 5 }
--========================
-- Analog output sub table
--=========================
dcPwrSysAnalogOpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of analog output variables in system controller analog output table."
::= { dcPwrSysAnalogOpTbl 1 }
dcPwrSysAnalogOpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysAnalogOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller analog output variables."
::= { dcPwrSysAnalogOpTbl 2 }
dcPwrSysAnalogOpEntry OBJECT-TYPE
SYNTAX DcPwrSysAnalogOpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller analog output group."
INDEX { dcPwrSysAnalogOpIndex }
::= { dcPwrSysAnalogOpTable 1 }
DcPwrSysAnalogOpEntry
::= SEQUENCE {
dcPwrSysAnalogOpIndex INTEGER,
dcPwrSysAnalogOpName DisplayString,
dcPwrSysAnalogOpIntegerValue INTEGER,
dcPwrSysAnalogOpStringValue DisplayString,
dcPwrSysAnalogOpSeverity INTEGER
}
dcPwrSysAnalogOpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the analog variable in the power system controller analog output group."
::= { dcPwrSysAnalogOpEntry 1 }
dcPwrSysAnalogOpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the analog variable as reported by the DC power system controller analog output group."
::= { dcPwrSysAnalogOpEntry 2 }
dcPwrSysAnalogOpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the analog variable as reported by the DC power system controller analog output group."
::= { dcPwrSysAnalogOpEntry 3 }
dcPwrSysAnalogOpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the analog variable as reported by the DC power system controller analog output group."
::= { dcPwrSysAnalogOpEntry 4 }
dcPwrSysAnalogOpSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of analog severity level of the extra variable as reported by the DC power system controller analog output group."
::= { dcPwrSysAnalogOpEntry 5 }
--=================
-- Alarm table
--=================
--============================
-- Rectifier alarm group
--============================
dcPwrSysRectAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of rectifier alarm variables in system controller alarm table."
::= { dcPwrSysRectAlrmTbl 1 }
dcPwrSysRectAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysRectAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller rectifier alarm variables."
::= { dcPwrSysRectAlrmTbl 2 }
dcPwrSysRectAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysRectAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller rectifier alarm group."
INDEX { dcPwrSysRectAlrmIndex }
::= { dcPwrSysRectAlrmTable 1 }
DcPwrSysRectAlrmEntry
::= SEQUENCE {
dcPwrSysRectAlrmIndex INTEGER,
dcPwrSysRectAlrmName DisplayString,
dcPwrSysRectAlrmIntegerValue INTEGER,
dcPwrSysRectAlrmStringValue DisplayString,
dcPwrSysRectAlrmSeverity INTEGER
}
dcPwrSysRectAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table rectifier alarm group."
::= { dcPwrSysRectAlrmEntry 1 }
dcPwrSysRectAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller rectifier alarm group."
::= { dcPwrSysRectAlrmEntry 2 }
dcPwrSysRectAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller rectifier alarm group."
::= { dcPwrSysRectAlrmEntry 3 }
dcPwrSysRectAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller rectifier alarm group."
::= { dcPwrSysRectAlrmEntry 4 }
dcPwrSysRectAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller rectifier alarm group."
::= { dcPwrSysRectAlrmEntry 5 }
--============================
-- Digital alarm group
--============================
dcPwrSysDigAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of digital alarm variables in system controller alarm table."
::= { dcPwrSysDigAlrmTbl 1 }
dcPwrSysDigAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysDigAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller digital alarm variables."
::= { dcPwrSysDigAlrmTbl 2 }
dcPwrSysDigAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysDigAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller digital alarm group."
INDEX { dcPwrSysDigAlrmIndex }
::= { dcPwrSysDigAlrmTable 1 }
DcPwrSysDigAlrmEntry
::= SEQUENCE {
dcPwrSysDigAlrmIndex INTEGER,
dcPwrSysDigAlrmName DisplayString,
dcPwrSysDigAlrmIntegerValue INTEGER,
dcPwrSysDigAlrmStringValue DisplayString,
dcPwrSysDigAlrmSeverity INTEGER
}
dcPwrSysDigAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table digital alarm group."
::= { dcPwrSysDigAlrmEntry 1 }
dcPwrSysDigAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller digital alarm group."
::= { dcPwrSysDigAlrmEntry 2 }
dcPwrSysDigAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller digital alarm group."
::= { dcPwrSysDigAlrmEntry 3 }
dcPwrSysDigAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller digital alarm group."
::= { dcPwrSysDigAlrmEntry 4 }
dcPwrSysDigAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller digital alarm group."
::= { dcPwrSysDigAlrmEntry 5 }
--============================
-- Current alarm group
--============================
dcPwrSysCurrAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of current alarm variables in system controller alarm table."
::= { dcPwrSysCurrAlrmTbl 1 }
dcPwrSysCurrAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCurrAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller current alarm variables."
::= { dcPwrSysCurrAlrmTbl 2 }
dcPwrSysCurrAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysCurrAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller current alarm group."
INDEX { dcPwrSysCurrAlrmIndex }
::= { dcPwrSysCurrAlrmTable 1 }
DcPwrSysCurrAlrmEntry
::= SEQUENCE {
dcPwrSysCurrAlrmIndex INTEGER,
dcPwrSysCurrAlrmName DisplayString,
dcPwrSysCurrAlrmIntegerValue INTEGER,
dcPwrSysCurrAlrmStringValue DisplayString,
dcPwrSysCurrAlrmSeverity INTEGER
}
dcPwrSysCurrAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table current alarm group."
::= { dcPwrSysCurrAlrmEntry 1 }
dcPwrSysCurrAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller current alarm group."
::= { dcPwrSysCurrAlrmEntry 2 }
dcPwrSysCurrAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller current alarm group."
::= { dcPwrSysCurrAlrmEntry 3 }
dcPwrSysCurrAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller current alarm group."
::= { dcPwrSysCurrAlrmEntry 4 }
dcPwrSysCurrAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller current alarm group."
::= { dcPwrSysCurrAlrmEntry 5 }
--============================
-- Voltage alarm group
--============================
dcPwrSysVoltAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of voltage alarm variables in system controller alarm table."
::= { dcPwrSysVoltAlrmTbl 1 }
dcPwrSysVoltAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysVoltAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller voltage alarm variables."
::= { dcPwrSysVoltAlrmTbl 2 }
dcPwrSysVoltAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysVoltAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller voltage alarm group."
INDEX { dcPwrSysVoltAlrmIndex }
::= { dcPwrSysVoltAlrmTable 1 }
DcPwrSysVoltAlrmEntry
::= SEQUENCE {
dcPwrSysVoltAlrmIndex INTEGER,
dcPwrSysVoltAlrmName DisplayString,
dcPwrSysVoltAlrmIntegerValue INTEGER,
dcPwrSysVoltAlrmStringValue DisplayString,
dcPwrSysVoltAlrmSeverity INTEGER
}
dcPwrSysVoltAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table voltage alarm group."
::= { dcPwrSysVoltAlrmEntry 1 }
dcPwrSysVoltAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller voltage alarm group."
::= { dcPwrSysVoltAlrmEntry 2 }
dcPwrSysVoltAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller voltage alarm group."
::= { dcPwrSysVoltAlrmEntry 3 }
dcPwrSysVoltAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller voltage alarm group."
::= { dcPwrSysVoltAlrmEntry 4 }
dcPwrSysVoltAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller voltage alarm group."
::= { dcPwrSysVoltAlrmEntry 5 }
--============================
-- Battery alarm group
--============================
dcPwrSysBattAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of battery alarm variables in system controller alarm table."
::= { dcPwrSysBattAlrmTbl 1 }
dcPwrSysBattAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysBattAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller battery alarm variables."
::= { dcPwrSysBattAlrmTbl 2 }
dcPwrSysBattAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysBattAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller battery alarm group."
INDEX { dcPwrSysBattAlrmIndex }
::= { dcPwrSysBattAlrmTable 1 }
DcPwrSysBattAlrmEntry
::= SEQUENCE {
dcPwrSysBattAlrmIndex INTEGER,
dcPwrSysBattAlrmName DisplayString,
dcPwrSysBattAlrmIntegerValue INTEGER,
dcPwrSysBattAlrmStringValue DisplayString,
dcPwrSysBattAlrmSeverity INTEGER
}
dcPwrSysBattAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table battery alarm group."
::= { dcPwrSysBattAlrmEntry 1 }
dcPwrSysBattAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller battery alarm group."
::= { dcPwrSysBattAlrmEntry 2 }
dcPwrSysBattAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller battery alarm group."
::= { dcPwrSysBattAlrmEntry 3 }
dcPwrSysBattAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller battery alarm group."
::= { dcPwrSysBattAlrmEntry 4 }
dcPwrSysBattAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller battery alarm group."
::= { dcPwrSysBattAlrmEntry 5 }
--============================
-- Temperature alarm group
--============================
dcPwrSysTempAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of temperature alarm variables in system controller alarm table."
::= { dcPwrSysTempAlrmTbl 1 }
dcPwrSysTempAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysTempAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller temperature alarm variables."
::= { dcPwrSysTempAlrmTbl 2 }
dcPwrSysTempAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysTempAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller temperature alarm group."
INDEX { dcPwrSysTempAlrmIndex }
::= { dcPwrSysTempAlrmTable 1 }
DcPwrSysTempAlrmEntry
::= SEQUENCE {
dcPwrSysTempAlrmIndex INTEGER,
dcPwrSysTempAlrmName DisplayString,
dcPwrSysTempAlrmIntegerValue INTEGER,
dcPwrSysTempAlrmStringValue DisplayString,
dcPwrSysTempAlrmSeverity INTEGER
}
dcPwrSysTempAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table temperature alarm group."
::= { dcPwrSysTempAlrmEntry 1 }
dcPwrSysTempAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller temperature alarm group."
::= { dcPwrSysTempAlrmEntry 2 }
dcPwrSysTempAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller temperature alarm group."
::= { dcPwrSysTempAlrmEntry 3 }
dcPwrSysTempAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller temperature alarm group."
::= { dcPwrSysTempAlrmEntry 4 }
dcPwrSysTempAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller temperature alarm group."
::= { dcPwrSysTempAlrmEntry 5 }
--============================
-- Custom alarm group
--============================
dcPwrSysCustomAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of custom alarm variables in system controller alarm table."
::= { dcPwrSysCustomAlrmTbl 1 }
dcPwrSysCustomAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCustomAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller custom alarm variables."
::= { dcPwrSysCustomAlrmTbl 2 }
dcPwrSysCustomAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysCustomAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller custom alarm group."
INDEX { dcPwrSysCustomAlrmIndex }
::= { dcPwrSysCustomAlrmTable 1 }
DcPwrSysCustomAlrmEntry
::= SEQUENCE {
dcPwrSysCustomAlrmIndex INTEGER,
dcPwrSysCustomAlrmName DisplayString,
dcPwrSysCustomAlrmIntegerValue INTEGER,
dcPwrSysCustomAlrmStringValue DisplayString,
dcPwrSysCustomAlrmSeverity INTEGER
}
dcPwrSysCustomAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table custom alarm group."
::= { dcPwrSysCustomAlrmEntry 1 }
dcPwrSysCustomAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller custom alarm group."
::= { dcPwrSysCustomAlrmEntry 2 }
dcPwrSysCustomAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller custom alarm group."
::= { dcPwrSysCustomAlrmEntry 3 }
dcPwrSysCustomAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller custom alarm group."
::= { dcPwrSysCustomAlrmEntry 4 }
dcPwrSysCustomAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller custom alarm group."
::= { dcPwrSysCustomAlrmEntry 5 }
--============================
-- Misc alarm group
--============================
dcPwrSysMiscAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of misc alarm variables in system controller alarm table."
::= { dcPwrSysMiscAlrmTbl 1 }
dcPwrSysMiscAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysMiscAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of DC power system controller misc alarm variables."
::= { dcPwrSysMiscAlrmTbl 2 }
dcPwrSysMiscAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysMiscAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the DC power system controller misc alarm group."
INDEX { dcPwrSysMiscAlrmIndex }
::= { dcPwrSysMiscAlrmTable 1 }
DcPwrSysMiscAlrmEntry
::= SEQUENCE {
dcPwrSysMiscAlrmIndex INTEGER,
dcPwrSysMiscAlrmName DisplayString,
dcPwrSysMiscAlrmIntegerValue INTEGER,
dcPwrSysMiscAlrmStringValue DisplayString,
dcPwrSysMiscAlrmSeverity INTEGER
}
dcPwrSysMiscAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table misc alarm group."
::= { dcPwrSysMiscAlrmEntry 1 }
dcPwrSysMiscAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the DC power system controller misc alarm group."
::= { dcPwrSysMiscAlrmEntry 2 }
dcPwrSysMiscAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the DC power system controller misc alarm group."
::= { dcPwrSysMiscAlrmEntry 3 }
dcPwrSysMiscAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the DC power system controller misc alarm group."
::= { dcPwrSysMiscAlrmEntry 4 }
dcPwrSysMiscAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the DC power system controller misc alarm group."
::= { dcPwrSysMiscAlrmEntry 5 }
--============================
-- Control alarm group
--============================
dcPwrSysCtrlAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of control alarm variables."
::= { dcPwrSysCtrlAlrmTbl 1 }
dcPwrSysCtrlAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCtrlAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of control alarm variables."
::= { dcPwrSysCtrlAlrmTbl 2 }
dcPwrSysCtrlAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysCtrlAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry of the control alarm group"
INDEX { dcPwrSysCtrlAlrmIndex }
::= { dcPwrSysCtrlAlrmTable 1 }
DcPwrSysCtrlAlrmEntry
::= SEQUENCE {
dcPwrSysCtrlAlrmIndex INTEGER,
dcPwrSysCtrlAlrmName DisplayString,
dcPwrSysCtrlAlrmIntegerValue INTEGER,
dcPwrSysCtrlAlrmStringValue DisplayString,
dcPwrSysCtrlAlrmSeverity INTEGER
}
dcPwrSysCtrlAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the control alarm group."
::= { dcPwrSysCtrlAlrmEntry 1 }
dcPwrSysCtrlAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the control alarm group."
::= { dcPwrSysCtrlAlrmEntry 2 }
dcPwrSysCtrlAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the control alarm group."
::= { dcPwrSysCtrlAlrmEntry 3 }
dcPwrSysCtrlAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the control alarm group."
::= { dcPwrSysCtrlAlrmEntry 4 }
dcPwrSysCtrlAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the control alarm group."
::= { dcPwrSysCtrlAlrmEntry 5 }
--============================
-- ADIO alarm group
--============================
dcPwrSysAdioAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of control alarm variables in Adio alarm table."
::= { dcPwrSysAdioAlrmTbl 1 }
dcPwrSysAdioAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysAdioAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of Adio alarm variables."
::= { dcPwrSysAdioAlrmTbl 2 }
dcPwrSysAdioAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysAdioAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the Adio alarm group."
INDEX { dcPwrSysAdioAlrmIndex }
::= { dcPwrSysAdioAlrmTable 1 }
DcPwrSysAdioAlrmEntry
::= SEQUENCE {
dcPwrSysAdioAlrmIndex INTEGER,
dcPwrSysAdioAlrmName DisplayString,
dcPwrSysAdioAlrmIntegerValue INTEGER,
dcPwrSysAdioAlrmStringValue DisplayString,
dcPwrSysAdioAlrmSeverity INTEGER
}
dcPwrSysAdioAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the table Adio alarm group."
::= { dcPwrSysAdioAlrmEntry 1 }
dcPwrSysAdioAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the Adio alarm group."
::= { dcPwrSysAdioAlrmEntry 2 }
dcPwrSysAdioAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the Adio alarm group."
::= { dcPwrSysAdioAlrmEntry 3 }
dcPwrSysAdioAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the Adio alarm group."
::= { dcPwrSysAdioAlrmEntry 4 }
dcPwrSysAdioAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the control alarm group."
::= { dcPwrSysAdioAlrmEntry 5 }
--============================
-- Converter alarm group
--============================
dcPwrSysConvAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Converter alarm variables in system controller alarm table."
::= { dcPwrSysConvAlrmTbl 1 }
dcPwrSysConvAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysConvAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of Converter alarm variables."
::= { dcPwrSysConvAlrmTbl 2 }
dcPwrSysConvAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysConvAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the Converter alarm group."
INDEX { dcPwrSysConvAlrmIndex }
::= { dcPwrSysConvAlrmTable 1 }
DcPwrSysConvAlrmEntry
::= SEQUENCE {
dcPwrSysConvAlrmIndex INTEGER,
dcPwrSysConvAlrmName DisplayString,
dcPwrSysConvAlrmIntegerValue INTEGER,
dcPwrSysConvAlrmStringValue DisplayString,
dcPwrSysConvAlrmSeverity INTEGER
}
dcPwrSysConvAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table Converter alarm group."
::= { dcPwrSysConvAlrmEntry 1 }
dcPwrSysConvAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the Converter alarm group."
::= { dcPwrSysConvAlrmEntry 2 }
dcPwrSysConvAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the Converter alarm group."
::= { dcPwrSysConvAlrmEntry 3 }
dcPwrSysConvAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the Converter alarm group."
::= { dcPwrSysConvAlrmEntry 4 }
dcPwrSysConvAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the Converter alarm group."
::= { dcPwrSysConvAlrmEntry 5 }
--============================
-- alarm group
--============================
dcPwrSysInvAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of alarm variables in system controller alarm table"
::= { dcPwrSysInvAlrmTbl 1 }
dcPwrSysInvAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysInvAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of power system controller Inv alarm variables"
::= { dcPwrSysInvAlrmTbl 2 }
dcPwrSysInvAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysInvAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the power system controller Inv alarm group"
INDEX { dcPwrSysInvAlrmIndex }
::= { dcPwrSysInvAlrmTable 1 }
DcPwrSysInvAlrmEntry
::= SEQUENCE {
dcPwrSysInvAlrmIndex INTEGER,
dcPwrSysInvAlrmName DisplayString,
dcPwrSysInvAlrmIntegerValue INTEGER,
dcPwrSysInvAlrmStringValue DisplayString,
dcPwrSysInvAlrmSeverity INTEGER
}
dcPwrSysInvAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrSysInvAlrmEntry 1 }
dcPwrSysInvAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrSysInvAlrmEntry 2 }
dcPwrSysInvAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrSysInvAlrmEntry 3 }
dcPwrSysInvAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrSysInvAlrmEntry 4 }
dcPwrSysInvAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrSysInvAlrmEntry 5 }
--============================
-- Lps alarm group
--============================
dcPwrSysLpsAlrmCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of LPS alarm variables in system controller alarm table."
::= { dcPwrSysLpsAlrmTbl 1 }
dcPwrSysLpsAlrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysLpsAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of LPS alarm variables."
::= { dcPwrSysLpsAlrmTbl 2 }
dcPwrSysLpsAlrmEntry OBJECT-TYPE
SYNTAX DcPwrSysLpsAlrmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the LPS alarm group."
INDEX { dcPwrSysLpsAlrmIndex }
::= { dcPwrSysLpsAlrmTable 1 }
DcPwrSysLpsAlrmEntry
::= SEQUENCE {
dcPwrSysLpsAlrmIndex INTEGER,
dcPwrSysLpsAlrmName DisplayString,
dcPwrSysLpsAlrmIntegerValue INTEGER,
dcPwrSysLpsAlrmStringValue DisplayString,
dcPwrSysLpsAlrmSeverity INTEGER
}
dcPwrSysLpsAlrmIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the alarm variable in the DC power system controller table LPS alarm group."
::= { dcPwrSysLpsAlrmEntry 1 }
dcPwrSysLpsAlrmName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the alarm variable as reported by the LPS alarm group."
::= { dcPwrSysLpsAlrmEntry 2 }
dcPwrSysLpsAlrmIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the alarm variable as reported by the LPS alarm group."
::= { dcPwrSysLpsAlrmEntry 3 }
dcPwrSysLpsAlrmStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the alarm variable as reported by the LPS alarm group."
::= { dcPwrSysLpsAlrmEntry 4 }
dcPwrSysLpsAlrmSeverity OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of alarm severity level of the extra variable as reported by the LPS alarm group."
::= { dcPwrSysLpsAlrmEntry 5 }
--============
-- Input table
--============
--=====================
-- Digital input group
--=====================
dcPwrSysDigIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of digital input variables in system controller digital input table."
::= { dcPwrSysDigIpTbl 1 }
dcPwrSysDigIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysDigIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of digital input variables."
::= { dcPwrSysDigIpTbl 2 }
dcPwrSysDigIpEntry OBJECT-TYPE
SYNTAX DcPwrSysDigIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the digital input group."
INDEX { dcPwrSysDigIpIndex }
::= { dcPwrSysDigIpTable 1 }
DcPwrSysDigIpEntry
::= SEQUENCE {
dcPwrSysDigIpIndex INTEGER,
dcPwrSysDigIpName DisplayString,
dcPwrSysDigIpIntegerValue INTEGER,
dcPwrSysDigIpStringValue DisplayString
}
dcPwrSysDigIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the digital input variable in the table digital input group."
::= { dcPwrSysDigIpEntry 1 }
dcPwrSysDigIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the digital input variable as reported by the digital input group."
::= { dcPwrSysDigIpEntry 2 }
dcPwrSysDigIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the digital input variable as reported by the digital input group."
::= { dcPwrSysDigIpEntry 3 }
dcPwrSysDigIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the digital input variable as reported by the digital input group."
::= { dcPwrSysDigIpEntry 4 }
--=========================
-- Controller input group
--=========================
dcPwrSysCntrlrIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of controller input variables in system controller controller input table."
::= { dcPwrSysCntrlrIpTbl 1 }
dcPwrSysCntrlrIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCntrlrIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of controller input variables."
::= { dcPwrSysCntrlrIpTbl 2 }
dcPwrSysCntrlrIpEntry OBJECT-TYPE
SYNTAX DcPwrSysCntrlrIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the controller input group."
INDEX { dcPwrSysCntrlrIpIndex }
::= { dcPwrSysCntrlrIpTable 1 }
DcPwrSysCntrlrIpEntry
::= SEQUENCE {
dcPwrSysCntrlrIpIndex INTEGER,
dcPwrSysCntrlrIpName DisplayString,
dcPwrSysCntrlrIpIntegerValue INTEGER,
dcPwrSysCntrlrIpStringValue DisplayString
}
dcPwrSysCntrlrIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the controller input variable in the table controller input group."
::= { dcPwrSysCntrlrIpEntry 1 }
dcPwrSysCntrlrIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the controller input variable as reported by the controller input group."
::= { dcPwrSysCntrlrIpEntry 2 }
dcPwrSysCntrlrIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the controller input variable as reported by the controller input group."
::= { dcPwrSysCntrlrIpEntry 3 }
dcPwrSysCntrlrIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the controller input variable as reported by the controller input group."
::= { dcPwrSysCntrlrIpEntry 4 }
--========================
-- Rectifier input group
--========================
dcPwrSysRectIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of rectifier input variables in system controller rectifier input table."
::= { dcPwrSysRectIpTbl 1 }
dcPwrSysRectIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysRectIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of rectifier input variables."
::= { dcPwrSysRectIpTbl 2 }
dcPwrSysRectIpEntry OBJECT-TYPE
SYNTAX DcPwrSysRectIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the rectifier input group."
INDEX { dcPwrSysRectIpIndex }
::= { dcPwrSysRectIpTable 1 }
DcPwrSysRectIpEntry
::= SEQUENCE {
dcPwrSysRectIpIndex INTEGER,
dcPwrSysRectIpName DisplayString,
dcPwrSysRectIpIntegerValue INTEGER,
dcPwrSysRectIpStringValue DisplayString
}
dcPwrSysRectIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the rectifier input variable in the table rectifier input group."
::= { dcPwrSysRectIpEntry 1 }
dcPwrSysRectIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the rectifier input variable as reported by the rectifier input group."
::= { dcPwrSysRectIpEntry 2 }
dcPwrSysRectIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the rectifier input variable as reported by the rectifier input group."
::= { dcPwrSysRectIpEntry 3 }
dcPwrSysRectIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the rectifier input variable as reported by the rectifier input group."
::= { dcPwrSysRectIpEntry 4 }
--======================
-- Custom input group
--======================
dcPwrSysCustomIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of custom input variables in system controller custom input table."
::= { dcPwrSysCustomIpTbl 1 }
dcPwrSysCustomIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCustomIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of digital custom variables."
::= { dcPwrSysCustomIpTbl 2 }
dcPwrSysCustomIpEntry OBJECT-TYPE
SYNTAX DcPwrSysCustomIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the custom input group."
INDEX { dcPwrSysCustomIpIndex }
::= { dcPwrSysCustomIpTable 1 }
DcPwrSysCustomIpEntry
::= SEQUENCE {
dcPwrSysCustomIpIndex INTEGER,
dcPwrSysCustomIpName DisplayString,
dcPwrSysgCustomIpIntegerValue INTEGER,
dcPwrSysCustomIpStringValue DisplayString
}
dcPwrSysCustomIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the custom input variable in the table custom input group."
::= { dcPwrSysCustomIpEntry 1 }
dcPwrSysCustomIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the custom input variable as reported by the custom input group."
::= { dcPwrSysCustomIpEntry 2 }
dcPwrSysgCustomIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The integer value of the custom input variable as reported by the custom input group."
::= { dcPwrSysCustomIpEntry 3 }
dcPwrSysCustomIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the custom input variable as reported by the custom input group."
::= { dcPwrSysCustomIpEntry 4 }
--========================
-- Converter input group
--========================
dcPwrSysConvIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Converter input variables in system controller Converter input table."
::= { dcPwrSysConvIpTbl 1 }
dcPwrSysConvIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysConvIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of Converter input variables."
::= { dcPwrSysConvIpTbl 2 }
dcPwrSysConvIpEntry OBJECT-TYPE
SYNTAX DcPwrSysConvIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the Converter input group."
INDEX { dcPwrSysConvIpIndex }
::= { dcPwrSysConvIpTable 1 }
DcPwrSysConvIpEntry
::= SEQUENCE {
dcPwrSysConvIpIndex INTEGER,
dcPwrSysConvIpName DisplayString,
dcPwrSysConvIpIntegerValue INTEGER,
dcPwrSysConvIpStringValue DisplayString
}
dcPwrSysConvIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the Converter input variable in the table Converter input group."
::= { dcPwrSysConvIpEntry 1 }
dcPwrSysConvIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the Converter input variable as reported by the Converter input group."
::= { dcPwrSysConvIpEntry 2 }
dcPwrSysConvIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the Converter input variable as reported by the Converter input group."
::= { dcPwrSysConvIpEntry 3 }
dcPwrSysConvIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the Converter input variable as reported by the Converter input group."
::= { dcPwrSysConvIpEntry 4 }
--========================
-- Timer input group
--========================
dcPwrSysTimerIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Timer input variables in system controller Timer input table."
::= { dcPwrSysTimerIpTbl 1 }
dcPwrSysTimerIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysTimerIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of Timer input variables"
::= { dcPwrSysTimerIpTbl 2 }
dcPwrSysTimerIpEntry OBJECT-TYPE
SYNTAX DcPwrSysTimerIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the Timer input group"
INDEX { dcPwrSysTimerIpIndex }
::= { dcPwrSysTimerIpTable 1 }
DcPwrSysTimerIpEntry
::= SEQUENCE {
dcPwrSysTimerIpIndex INTEGER,
dcPwrSysTimerIpName DisplayString,
dcPwrSysTimerIpIntegerValue INTEGER,
dcPwrSysTimerIpStringValue DisplayString
}
dcPwrSysTimerIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the Timer input variable in the table Timer input group."
::= { dcPwrSysTimerIpEntry 1 }
dcPwrSysTimerIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the Timer input variable as reported by the Timer input group."
::= { dcPwrSysTimerIpEntry 2 }
dcPwrSysTimerIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the Timer input variable as reported by the Timer input group."
::= { dcPwrSysTimerIpEntry 3 }
dcPwrSysTimerIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the Timer input variable as reported by the Timer input group."
::= { dcPwrSysTimerIpEntry 4 }
--========================
-- Counter input group
--========================
dcPwrSysCounterIpCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of Counter input variables in system controller Counter input table."
::= { dcPwrSysCounterIpTbl 1 }
dcPwrSysCounterIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DcPwrSysCounterIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of Counter input variables."
::= { dcPwrSysCounterIpTbl 2 }
dcPwrSysCounterIpEntry OBJECT-TYPE
SYNTAX DcPwrSysCounterIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry into the Counter input group."
INDEX { dcPwrSysCounterIpIndex }
::= { dcPwrSysCounterIpTable 1 }
DcPwrSysCounterIpEntry
::= SEQUENCE {
dcPwrSysCounterIpIndex INTEGER,
dcPwrSysCounterIpName DisplayString,
dcPwrSysCounterIpIntegerValue INTEGER,
dcPwrSysCounterIpStringValue DisplayString
}
dcPwrSysCounterIpIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the Counter input variable in the table Counter input group."
::= { dcPwrSysCounterIpEntry 1 }
dcPwrSysCounterIpName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The description of the Counter input variable as reported by the Counter input group."
::= { dcPwrSysCounterIpEntry 2 }
dcPwrSysCounterIpIntegerValue OBJECT-TYPE
SYNTAX INTEGER (-1000000000..1000000000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The integer value of the Counter input variable as reported by the Counter input group."
::= { dcPwrSysCounterIpEntry 3 }
dcPwrSysCounterIpStringValue OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The string value of the Counter input variable as reported by the Counter input group."
::= { dcPwrSysCounterIpEntry 4 }
--==========================================================================
-- LPS Data
--==========================================================================
lpsModuleCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of LPS modules acquired by the CXC."
::= { dcPwrSysLpsTbl 1 }
lpsModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of LPS modules."
::= { dcPwrSysLpsTbl 2 }
lpsModuleEntry OBJECT-TYPE
SYNTAX LpsModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table of LPS modules."
INDEX { lpsModuleIndex }
::= { lpsModuleTable 1 }
LpsModuleEntry
::= SEQUENCE {
lpsModuleIndex INTEGER,
lpsShelfId INTEGER,
lpsPosition INTEGER,
lpsInputVoltage INTEGER,
lpsHeatsinkTemperature INTEGER,
lpsAmbientTemperature INTEGER,
lpsSerialNumber DisplayString,
lpsDeviceName DisplayString,
lpsSoftwareVersionNumber DisplayString
}
lpsModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the LPS module."
::= { lpsModuleEntry 1 }
lpsShelfId OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Shelf ID - identifies the shelf in which this LPS is located."
::= { lpsModuleEntry 2 }
lpsPosition OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Position (slot ID) - identifies the position within the shelf."
::= { lpsModuleEntry 3 }
lpsInputVoltage OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input Voltage"
::= { lpsModuleEntry 4 }
lpsHeatsinkTemperature OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Heatsink Temperature."
::= { lpsModuleEntry 5 }
lpsAmbientTemperature OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ambient Temperature"
::= { lpsModuleEntry 6 }
lpsSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS module serial number"
::= { lpsModuleEntry 7 }
lpsDeviceName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Device name."
::= { lpsModuleEntry 8 }
lpsSoftwareVersionNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS software version number."
::= { lpsModuleEntry 9 }
lpsModuleAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsModuleAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing LPS alarms."
::= { dcPwrSysLpsTbl 3 }
lpsModuleAlarmEntry OBJECT-TYPE
SYNTAX LpsModuleAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table of LPS alarms."
INDEX { lpsModuleIndex }
::= { lpsModuleAlarmTable 1 }
LpsModuleAlarmEntry
::= SEQUENCE {
lpsModuleAlarmEntryIndex INTEGER,
lpsHighInputVoltageAlarm INTEGER,
lpsLowInputVoltageAlarm INTEGER,
lpsAmbientHighAlarm INTEGER,
lpsHeatsinkHighAlarm INTEGER,
lpsMajorAlarm INTEGER,
lpsMinorAlarm INTEGER,
lpsOOTAlarm INTEGER,
lpsCommsLostAlarm INTEGER
}
lpsModuleAlarmEntryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the LPS module."
::= { lpsModuleAlarmEntry 1 }
lpsHighInputVoltageAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input voltage is too high."
::= { lpsModuleAlarmEntry 2 }
lpsLowInputVoltageAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Input voltage is too low."
::= { lpsModuleAlarmEntry 3 }
lpsAmbientHighAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Ambient temperature is too high."
::= { lpsModuleAlarmEntry 4 }
lpsHeatsinkHighAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Heatsink temperature is too high."
::= { lpsModuleAlarmEntry 5 }
lpsMajorAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Multiple LPS outputs have failed."
::= { lpsModuleAlarmEntry 6 }
lpsMinorAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A single LPS output has failed."
::= { lpsModuleAlarmEntry 7 }
lpsOOTAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The LPS settings do not match those required by the controller."
::= { lpsModuleAlarmEntry 8 }
lpsCommsLostAlarm OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The controller has lost communication with the LPS."
::= { lpsModuleAlarmEntry 9 }
lpsOutputVoltageTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsOutputVoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the output voltage of the LPS channels."
::= { dcPwrSysLpsTbl 4 }
lpsOutputVoltageEntry OBJECT-TYPE
SYNTAX LpsOutputVoltageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table containing the output voltage of the LPS channels."
INDEX { lpsModuleIndex }
::= { lpsOutputVoltageTable 1 }
LpsOutputVoltageEntry
::= SEQUENCE {
lpsOutputVoltageEntryIndex INTEGER,
lpsOutputVoltageChannel1 INTEGER,
lpsOutputVoltageChannel2 INTEGER,
lpsOutputVoltageChannel3 INTEGER,
lpsOutputVoltageChannel4 INTEGER,
}
lpsOutputVoltageEntryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "index"
::= { lpsOutputVoltageEntry 1 }
lpsOutputVoltageChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output voltage of LPS Channel 1."
::= { lpsOutputVoltageEntry 2 }
lpsOutputVoltageChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output voltage of LPS Channel 2."
::= { lpsOutputVoltageEntry 3 }
lpsOutputVoltageChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output voltage of LPS Channel 3."
::= { lpsOutputVoltageEntry 4 }
lpsOutputVoltageChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output voltage of LPS Channel 4."
::= { lpsOutputVoltageEntry 5 }
lpsOutputCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsOutputCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the output current of the LPS channels."
::= { dcPwrSysLpsTbl 5 }
lpsOutputCurrentEntry OBJECT-TYPE
SYNTAX LpsOutputCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table containing the output voltage of the LPS channels."
INDEX { lpsModuleIndex }
::= { lpsOutputCurrentTable 1 }
LpsOutputCurrentEntry
::= SEQUENCE {
lpsOutputCurrentEntryIndex INTEGER,
lpsOutputCurrentChannel1 INTEGER,
lpsOutputCurrentChannel2 INTEGER,
lpsOutputCurrentChannel3 INTEGER,
lpsOutputCurrentChannel4 INTEGER
}
lpsOutputCurrentEntryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "index"
::= { lpsOutputCurrentEntry 1 }
lpsOutputCurrentChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output current of LPS Channel 1."
::= { lpsOutputCurrentEntry 2 }
lpsOutputCurrentChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output current of LPS Channel 2."
::= { lpsOutputCurrentEntry 3 }
lpsOutputCurrentChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output current of LPS Channel 3."
::= { lpsOutputCurrentEntry 4 }
lpsOutputCurrentChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The output current of LPS Channel 4."
::= { lpsOutputCurrentEntry 5 }
lpsChannelStatusFaultsTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsChannelStatusFaultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing the faults for each LPS channel."
::= { dcPwrSysLpsTbl 6 }
lpsChannelStatusFaultsEntry OBJECT-TYPE
SYNTAX LpsChannelStatusFaultsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table containing the faults for each LPS channel."
INDEX { lpsModuleIndex }
::= { lpsChannelStatusFaultsTable 1 }
LpsChannelStatusFaultsEntry
::= SEQUENCE {
lpsChannelStatusFaultsEntryIndex INTEGER,
lpsGfiChannel1 INTEGER,
lpsFuseChannel1 INTEGER,
lpsOvpChannel1 INTEGER,
lpsOverCurrentChannel1 INTEGER,
lpsLowOutputVoltageChannel1 INTEGER,
lpsRemoteShutdownChannel1 INTEGER,
lpsGfiChannel2 INTEGER,
lpsFuseChannel2 INTEGER,
lpsOvpChannel2 INTEGER,
lpsOverCurrentChannel2 INTEGER,
lpsLowOutputVoltageChannel2 INTEGER,
lpsRemoteShutdownChannel2 INTEGER,
lpsGfiChannel3 INTEGER,
lpsFuseChannel3 INTEGER,
lpsOvpChannel3 INTEGER,
lpsOverCurrentChannel3 INTEGER,
lpsLowOutputVoltageChannel3 INTEGER,
lpsRemoteShutdownChannel3 INTEGER,
lpsGfiChannel4 INTEGER,
lpsFuseChannel4 INTEGER,
lpsOvpChannel4 INTEGER,
lpsOverCurrentChannel4 INTEGER,
lpsLowOutputVoltageChannel4 INTEGER,
lpsRemoteShutdownChannel4 INTEGER,
lpsLowCurrent1 INTEGER,
lpsTransientOVP1 INTEGER,
lpsTransientGFI1 INTEGER,
lpsTransientVoutLow1 INTEGER,
lpsLowCurrent2 INTEGER,
lpsTransientOVP2 INTEGER,
lpsTransientGFI2 INTEGER,
lpsTransientVoutLow2 INTEGER,
lpsLowCurrent3 INTEGER,
lpsTransientOVP3 INTEGER,
lpsTransientGFI3 INTEGER,
lpsTransientVoutLow3 INTEGER,
lpsLowCurrent4 INTEGER,
lpsTransientOVP4 INTEGER,
lpsTransientGFI4 INTEGER,
lpsTransientVoutLow4 INTEGER,
lpsCurrentSensorShorted1 INTEGER,
lpsCurrentSensorShorted2 INTEGER,
lpsCurrentSensorShorted3 INTEGER,
lpsCurrentSensorShorted4 INTEGER
}
lpsChannelStatusFaultsEntryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "index"
::= { lpsChannelStatusFaultsEntry 1 }
lpsGfiChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has a GFI fault."
::= { lpsChannelStatusFaultsEntry 2 }
lpsFuseChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has a fuse fault."
::= { lpsChannelStatusFaultsEntry 3 }
lpsOvpChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has an OVP fault."
::= { lpsChannelStatusFaultsEntry 4 }
lpsOverCurrentChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has a Over-Current (OCP) fault."
::= { lpsChannelStatusFaultsEntry 5 }
lpsLowOutputVoltageChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has low output voltage."
::= { lpsChannelStatusFaultsEntry 6 }
lpsRemoteShutdownChannel1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has been remotely shut down."
::= { lpsChannelStatusFaultsEntry 7 }
lpsGfiChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has a GFI fault."
::= { lpsChannelStatusFaultsEntry 8 }
lpsFuseChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has a fuse fault."
::= { lpsChannelStatusFaultsEntry 9 }
lpsOvpChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has an OVP fault."
::= { lpsChannelStatusFaultsEntry 10 }
lpsOverCurrentChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has a Over-Current (OCP) fault."
::= { lpsChannelStatusFaultsEntry 11 }
lpsLowOutputVoltageChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has low output voltage."
::= { lpsChannelStatusFaultsEntry 12 }
lpsRemoteShutdownChannel2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has been remotely shut down."
::= { lpsChannelStatusFaultsEntry 13 }
lpsGfiChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has a GFI fault."
::= { lpsChannelStatusFaultsEntry 14 }
lpsFuseChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has a fuse fault."
::= { lpsChannelStatusFaultsEntry 15 }
lpsOvpChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has an OVP fault."
::= { lpsChannelStatusFaultsEntry 16 }
lpsOverCurrentChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has a Over-Current (OCP) fault."
::= { lpsChannelStatusFaultsEntry 17 }
lpsLowOutputVoltageChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has low output voltage."
::= { lpsChannelStatusFaultsEntry 18 }
lpsRemoteShutdownChannel3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has been remotely shut down."
::= { lpsChannelStatusFaultsEntry 19 }
lpsGfiChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has a GFI fault."
::= { lpsChannelStatusFaultsEntry 20 }
lpsFuseChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has a fuse fault."
::= { lpsChannelStatusFaultsEntry 21 }
lpsOvpChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has an OVP fault."
::= { lpsChannelStatusFaultsEntry 22 }
lpsOverCurrentChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has a Over-Current (OCP) fault."
::= { lpsChannelStatusFaultsEntry 23 }
lpsLowOutputVoltageChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has low output voltage."
::= { lpsChannelStatusFaultsEntry 24 }
lpsRemoteShutdownChannel4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has been remotely shut down."
::= { lpsChannelStatusFaultsEntry 25 }
lpsLowCurrent1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 has a low current fault."
::= { lpsChannelStatusFaultsEntry 26 }
lpsTransientOVP1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 had a transient OVP event."
::= { lpsChannelStatusFaultsEntry 27 }
lpsTransientGFI1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 had a transient GFI event."
::= { lpsChannelStatusFaultsEntry 28 }
lpsTransientVoutLow1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 had a transient Vout Low event."
::= { lpsChannelStatusFaultsEntry 29 }
lpsLowCurrent2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 has a low current fault."
::= { lpsChannelStatusFaultsEntry 30 }
lpsTransientOVP2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 had a transient OVP event."
::= { lpsChannelStatusFaultsEntry 31 }
lpsTransientGFI2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 had a transient GFI event."
::= { lpsChannelStatusFaultsEntry 32 }
lpsTransientVoutLow2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 had a transient Vout Low event."
::= { lpsChannelStatusFaultsEntry 33 }
lpsLowCurrent3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 has a low current fault."
::= { lpsChannelStatusFaultsEntry 34 }
lpsTransientOVP3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 had a transient OVP event."
::= { lpsChannelStatusFaultsEntry 35 }
lpsTransientGFI3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 had a transient GFI event."
::= { lpsChannelStatusFaultsEntry 36 }
lpsTransientVoutLow3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 had a transient Vout Low event."
::= { lpsChannelStatusFaultsEntry 37 }
lpsLowCurrent4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 has a low current fault."
::= { lpsChannelStatusFaultsEntry 38 }
lpsTransientOVP4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 had a transient OVP event."
::= { lpsChannelStatusFaultsEntry 39 }
lpsTransientGFI4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 had a transient GFI event."
::= { lpsChannelStatusFaultsEntry 40 }
lpsTransientVoutLow4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 had a transient Vout Low event."
::= { lpsChannelStatusFaultsEntry 41 }
lpsCurrentSensorShorted1 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 1 had a transient Current Sensor Shorted event."
::= { lpsChannelStatusFaultsEntry 42 }
lpsCurrentSensorShorted2 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 2 had a transient Current Sensor Shorted event."
::= { lpsChannelStatusFaultsEntry 43 }
lpsCurrentSensorShorted3 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 3 had a transient Current Sensor Shorted event."
::= { lpsChannelStatusFaultsEntry 44 }
lpsCurrentSensorShorted4 OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "LPS Channel 4 had a transient Current Sensor Shorted event."
::= { lpsChannelStatusFaultsEntry 45 }
lpsChannelInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF LpsChannelInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing extra info about the LPS channels."
::= { dcPwrSysLpsTbl 7 }
lpsChannelInfoEntry OBJECT-TYPE
SYNTAX LpsChannelInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table containing extra info about the LPS channels."
INDEX { lpsModuleIndex }
::= { lpsChannelInfoTable 1 }
LpsChannelInfoEntry
::= SEQUENCE {
lpsChannelInfoEntryIndex INTEGER,
lpsGroupChannel1 DisplayString,
lpsCustomText1Channel1 DisplayString,
lpsCustomText2Channel1 DisplayString,
lpsGroupChannel2 DisplayString,
lpsCustomText1Channel2 DisplayString,
lpsCustomText2Channel2 DisplayString,
lpsGroupChannel3 DisplayString,
lpsCustomText1Channel3 DisplayString,
lpsCustomText2Channel3 DisplayString,
lpsGroupChannel4 DisplayString,
lpsCustomText1Channel4 DisplayString,
lpsCustomText2Channel4 DisplayString
}
lpsChannelInfoEntryIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "index"
::= { lpsChannelInfoEntry 1 }
lpsGroupChannel1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The assigned group of LPS Channel 1."
::= { lpsChannelInfoEntry 2 }
lpsCustomText1Channel1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 1 for LPS Channel 1."
::= { lpsChannelInfoEntry 3 }
lpsCustomText2Channel1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 2 for LPS Channel 1."
::= { lpsChannelInfoEntry 4 }
lpsGroupChannel2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The assigned group of LPS Channel 2."
::= { lpsChannelInfoEntry 5 }
lpsCustomText1Channel2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 1 for LPS Channel 2."
::= { lpsChannelInfoEntry 6 }
lpsCustomText2Channel2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 2 for LPS Channel 2."
::= { lpsChannelInfoEntry 7 }
lpsGroupChannel3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The assigned group of LPS Channel 3."
::= { lpsChannelInfoEntry 8 }
lpsCustomText1Channel3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 1 for LPS Channel 3."
::= { lpsChannelInfoEntry 9 }
lpsCustomText2Channel3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 2 for LPS Channel 3."
::= { lpsChannelInfoEntry 10 }
lpsGroupChannel4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..25))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The assigned group of LPS Channel 4."
::= { lpsChannelInfoEntry 11 }
lpsCustomText1Channel4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 1 for LPS Channel 4."
::= { lpsChannelInfoEntry 12 }
lpsCustomText2Channel4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..50))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Custom Text 2 for LPS Channel 4."
::= { lpsChannelInfoEntry 13 }
--==========================================================================
-- The OBJECT IDENTIFIERs for the traps must be defined in this manner to
-- satisfy the NetSight MIB compiler; in particular, nodes cannot be defined
-- concatenated in a single line, but must be defined explicitly node by node
-- (hence, the dcPwrSysDevice.dcPwrSysTraps.dcPwrSysTrap definition)
-- In addition, forward references to extra system variables are needed for
-- dcPwrSysTrap by CastleRock SNMPc for event filter and match features.
--==========================================================================
dcPwrSysTrap OBJECT IDENTIFIER ::= { dcPwrSysTraps 0 }
--==========================================================================
-- Start of Traps
--==========================================================================
dcPwrSysAlarmActiveTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName,
dcPwrSysTimeStamp,
dcPwrSysAlarmTriggerValue
}
STATUS current
DESCRIPTION "A trap issued when one of the alarms on the became active."
::= { dcPwrSysTrap 1 }
dcPwrSysAlarmClearedTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName,
dcPwrSysAlarmTriggerValue
}
STATUS current
DESCRIPTION "A trap issued when one of the active alarms on the is cleared."
::= { dcPwrSysTrap 2 }
dcPwrSysRelayTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRelayIntegerValue,
dcPwrSysRelayStringValue,
dcPwrSysRelayIndex,
dcPwrSysRelaySeverity,
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap issued from a change in state in one of the relays on the DC power system controller."
::= { dcPwrSysTrap 3 }
dcPwrSysComOKTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap to indicate that communications with a DC power system controller has been established."
::= { dcPwrSysTrap 4 }
dcPwrSysComErrTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap to indicate that communications with a DC power system controller has been lost."
::= { dcPwrSysTrap 5 }
dcPwrSysAgentStartupTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap to indicate that the agent software has started up."
::= { dcPwrSysTrap 6 }
dcPwrSysAgentShutdownTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap to indicate that the agent software has shutdown."
::= { dcPwrSysTrap 7 }
dcPwrSysMajorAlarmActiveTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap issued as a summary of DC power system status. It is sent when the system goes into in Major Alarm"
::= { dcPwrSysTrap 8 }
dcPwrSysMajorAlarmClearedTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap issued as a summary of DC power system status. It is sent when the system comes out of Major Alarm"
::= { dcPwrSysTrap 9 }
dcPwrSysMinorAlarmActiveTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap issued as a summary of DC power system status. It is sent when the system goes into in Minor Alarm"
::= { dcPwrSysTrap 10 }
dcPwrSysMinorAlarmClearedTrap NOTIFICATION-TYPE
OBJECTS {
dcPwrSysRectAlrmStringValue,
dcPwrSysRectAlrmIndex,
dcPwrSysRectAlrmSeverity,
dcPwrSysSiteName
}
STATUS current
DESCRIPTION "A trap issued as a summary of DC power system status. It is sent when the system comes out of Minor Alarm"
::= { dcPwrSysTrap 11 }
--==========================================================================
-- Start of External Controls
--==========================================================================
dcPwrSysResyncAlarms OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Send/Resend all active alarms that were previously sent through SNMP notification."
::= { dcPwrExternalControls 1 }
--==========================================================================
-- Alarm Trigger
--==========================================================================
dcPwrSysAlarmTriggerValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrVarbindNameReference 1 }
--==========================================================================
-- Time stamp
--==========================================================================
dcPwrSysTimeStamp OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { dcPwrVarbindNameReference 2 }
END