SIXNET-MIB DEFINITIONS ::= BEGIN
--
-- SIXNET enterprise MIB tree
--
IMPORTS
Integer32, MODULE-IDENTITY, OBJECT-TYPE, enterprises FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
TEXTUAL-CONVENTION, TruthValue FROM SNMPv2-TC
InterfaceIndex FROM IF-MIB;
sixnet MODULE-IDENTITY
LAST-UPDATED "200904270000Z"
ORGANIZATION "www.sixnet.com"
CONTACT-INFO
"postal: SIXNET, LLC
SIXNET Technology Park
331 Ushers Road
Ballston Lake, NY 12019
email: support@sixnet.com"
DESCRIPTION
"Updated contact addresses"
REVISION "200904270000Z"
DESCRIPTION
"Added real-time ring status items"
REVISION "200812160000Z"
DESCRIPTION
"Top-level infrastructure of the SIXNET enterprise MIB tree"
REVISION "200607260000Z"
DESCRIPTION
"Revised testing section"
REVISION "200607140000Z"
DESCRIPTION
"et9ms -> etms with backwards-compatible aliases
add PPP
add conformance group"
REVISION "200512120000Z"
DESCRIPTION
"Added fields for v3.0 releases"
::= { enterprises 20540}
--
-- SIXNET enterprise-specific management objects
--
sixnetObjects OBJECT IDENTIFIER ::= {sixnet 1}
sixnetDevices OBJECT IDENTIFIER ::= {sixnet 2}
-- sixnetEnumerations OBJECT IDENTIFIER ::= {sixnet 3}
-- sixnetModuleIDs OBJECT IDENTIFIER ::= {sixnetEnumerations 1}
-- sixnetAgentOIDs OBJECT IDENTIFIER ::= {sixnetEnumerations 2}
sixnetExperimental OBJECT IDENTIFIER ::= {sixnet 9999}
--
-- A subtree specifically designed for private testing purposes.
-- No "public" management objects should ever be defined within this tree.
--
-- It is provided for private experimentation, prior to transferring a MIB
-- structure to another part of the overall OID tree
--
sixnetPlaypen OBJECT IDENTIFIER ::= {sixnetExperimental 9999}
--
-- Notifications
--
sixnetNotificationPrefix OBJECT IDENTIFIER ::= {sixnet 4}
sixnetNotifications OBJECT IDENTIFIER ::= {sixnetNotificationPrefix 0}
sixnetNotificationObjects OBJECT IDENTIFIER ::= {sixnetNotificationPrefix 1}
--
-- Conformance
--
sixnetConformance OBJECT IDENTIFIER ::= {sixnet 5}
sixnetCompliances OBJECT IDENTIFIER ::= {sixnetConformance 1}
sixnetGroups OBJECT IDENTIFIER ::= {sixnetConformance 2}
--
-- Devices
--
-- These names used to be used for all managed switches but it was
-- misleading becuase they didn't depend on port count. These
-- entries accomplish backwards-compatible "aliases"
--
-- These are deprecated and will be removed from a future version of
-- this MIB.
et9ms OBJECT IDENTIFIER ::= { sixnetDevices 1 }
et9msScalars OBJECT IDENTIFIER ::= { et9ms 1 }
etms OBJECT IDENTIFIER ::= { sixnetDevices 1 }
etmsScalars OBJECT IDENTIFIER ::= { etms 1 }
etmsTables OBJECT IDENTIFIER ::= { etms 2 }
-- etmsNotifications OBJECT IDENTIFIER ::= { etms 3 }
etmsTest OBJECT IDENTIFIER ::= { etms 9999 }
--
-- Scalars
--
SixnetDiscrete ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A discrete input or output value which may be turned on
or off or may have an unknown state."
SYNTAX INTEGER {
off(0),
on(1),
unknown(2)
}
p1status OBJECT-TYPE
SYNTAX SixnetDiscrete
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of P1 power input."
::= { etmsScalars 1 }
p2status OBJECT-TYPE
SYNTAX SixnetDiscrete
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of P2 power input."
::= { etmsScalars 2 }
oKstatus OBJECT-TYPE
SYNTAX SixnetDiscrete
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of OK relay output."
::= { etmsScalars 3 }
serialNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The serial number of the device."
::= { etmsScalars 4 }
sxid OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SXID of the device."
::= { etmsScalars 5 }
firmwareRevision OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The firmware revision."
::= { etmsScalars 6 }
fromPLCstatus OBJECT-TYPE
SYNTAX SixnetDiscrete
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of From PLC input."
::= { etmsScalars 7 }
-- The following two scalars are summary flags that can be calculated
-- from sxRingTable below.
sxAllRingsGood OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if all rings configured for this switch are complete."
::= { etmsScalars 8 }
sxAllRingNeighborsGood OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if all neighbors in all configured rings for this switch are
complete."
::= { etmsScalars 9 }
--
-- PPP
---
pppTable OBJECT-TYPE
SYNTAX SEQUENCE OF PppEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries."
::= { etmsTables 1 }
pppEntry OBJECT-TYPE
SYNTAX PppEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX { pppifIndex }
::= { pppTable 1 }
PppEntry ::=
SEQUENCE {
pppifIndex InterfaceIndex,
pppifOperStatus INTEGER
}
pppifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each interface. It
is recommended that values are assigned contiguously
starting from 1. The value for each interface sub-layer
must remain constant at least from one re-initialization of
the entity's network management system to the next re-
initialization."
::= { pppEntry 1 }
pppifOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
down(1),
up(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the interface."
::= { pppEntry 2 }
--
-- Ring table
--
-- There are two scalar summary flags, sxAllRingsGood and sxAllNeighborsGood,
-- which are calculated from the data in this table.
SxRingIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A unique value, greater than zero, identifying a ring in which this
switch participates."
SYNTAX Integer32 (1..2147483647)
sxRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF sxRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of configured rings."
::= { etmsTables 2 }
sxRingEntry OBJECT-TYPE
SYNTAX SxRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A row containing status and configuration information for a
particular ring."
INDEX { sxRingIndex }
::= { sxRingTable 1 }
SxRingEntry ::=
SEQUENCE {
sxRingIndex SxRingIndex,
sxRingName DisplayString,
sxRingGood TruthValue,
sxRingPrimarySeen TruthValue,
sxRingBackupSeen TruthValue,
sxRingPrimaryIf InterfaceIndex,
sxRingBackupIf InterfaceIndex
}
sxRingIndex OBJECT-TYPE
SYNTAX SxRingIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, identifying a ring in which this
switch participates."
::= { sxRingEntry 1 }
sxRingName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255)) -- current limit is 33 chars
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A name describing the ring, unique among configured rings. The name
has no inherent meaning to the switch."
::= { sxRingEntry 2 }
sxRingGood OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if the ring is complete, false otherwise."
::= { sxRingEntry 3 }
sxRingPrimarySeen OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if the switch has recently seen RPDUs from its primary neighbor
on this ring."
::= { sxRingEntry 4 }
sxRingBackupSeen OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"True if the switch has recently seen RPDUs from its backup neighbor
on this ring."
::= { sxRingEntry 5 }
sxRingPrimaryIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interface configured as the primary port for this
ring. Unique among all ports for all configured rings on this switch."
::= { sxRingEntry 6 }
sxRingBackupIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the interface configured as the backup port for this
ring. Unique among all ports for all configured rings on this switch."
::= { sxRingEntry 7 }
--
-- Conformance information
--
sixnetCompliance1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"This really just keeps MIB verification programs happy
because there is no external standard to which our private
MIB must conform."
MODULE -- this module
MANDATORY-GROUPS { sixnetSwitchGroup, sixnetTestGroup }
GROUP sixnetSwitchGroup
DESCRIPTION
"Public objects in SIXNET switches"
::= { sixnetCompliances 1 }
sixnetSwitchGroup OBJECT-GROUP
OBJECTS { p1status, p2status, oKstatus,
serialNumber, sxid, firmwareRevision,
fromPLCstatus, pppifOperStatus }
STATUS current
DESCRIPTION
"A collection of objects providing information about
SIXNET switches"
::= { sixnetGroups 1}
sixnetTestGroup OBJECT-GROUP
OBJECTS { ifAdminSpeed, ifAdminPower, ledTestTrigger,
sixnetConfigState, sixnetConfigResult, sixnetConfigServer,
sixnetConfigFile }
STATUS current
DESCRIPTION
"A collection of objects for testing."
::= { sixnetGroups 2}
--
-- Test
--
portTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries."
::= { etmsTest 1 }
portTestEntry OBJECT-TYPE
SYNTAX PortTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to a
particular interface."
INDEX { testifIndex }
::= { portTestTable 1 }
PortTestEntry ::=
SEQUENCE {
testifIndex InterfaceIndex,
ifAdminSpeed INTEGER,
ifAdminPower INTEGER
}
testifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each interface. It
is recommended that values are assigned contiguously
starting from 1. The value for each interface sub-layer
must remain constant at least from one re-initialization of
the entity's network management system to the next re-
initialization."
::= { portTestEntry 1 }
ifAdminSpeed OBJECT-TYPE
SYNTAX INTEGER {
m10(10),
m100(100),
g1(1000)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force port speed (in megabits/sec)"
::= { portTestEntry 2 }
ifAdminPower OBJECT-TYPE
SYNTAX INTEGER {
down(0),
up(1),
unknown(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The PHYs PwrDown bit. ifAdminPower in the down(2) state
indicates that the PHY control regsiter, bit 11 is 1
(Power Down). ifAdminPower in the up(1) date indicates
that the PHY control register, bit 11 is 0 (Normal
operation)"
::= { portTestEntry 3 }
ledTestTrigger OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
testing(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger LED test"
::= { etmsTest 2 }
sixnetTestConfig OBJECT IDENTIFIER ::= { etmsTest 3 }
-- Configuration state
--
-- Normally idle.
-- When management station has set server and file, it sets state to 1
-- When agent sees configure, it sets to working and begins work
-- When agent is done, it sets state to done
-- When management station sees done, it sets to idle.
-- If there was a problem during startup, state will always be crash
sixnetConfigState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
reserved(1),
configure(2),
working(3),
done(4),
crash(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trigger LED test"
::= { sixnetTestConfig 1 }
-- Result of configuration operation. agent sets this before setting
-- state to done. 'abort' means the script did not commit before quitting
sixnetConfigResult OBJECT-TYPE
SYNTAX INTEGER {
success(0),
failure(1),
abort(99)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Result of configuration. Valid only when configState is done."
::= { sixnetTestConfig 2 }
-- Configuration server
--
-- The agent will retrieve configFile from this address with TFTP
sixnetConfigServer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of the configuration server.
Typically an IP address but might be a FQDN."
::= { sixnetTestConfig 3 }
-- Configuration file
--
-- The agent retrieves this file from configServer when configState
-- goes to configure.
sixnetConfigFile OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file to retrieve and process."
::= { sixnetTestConfig 4 }
END