PRINTER-PORT-MONITOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32
FROM SNMPv2-SMI -- RFC 2578
TruthValue
FROM SNMPv2-TC -- RFC 2579
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF -- RFC 2580
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB; -- RFC 3411
ppmMIB MODULE-IDENTITY
LAST-UPDATED "200510250000Z"
ORGANIZATION "Printer Working Group, a Program of IEEE/ISTO"
CONTACT-INFO
"Editors:
Ron Bergman (Ricoh)
Phone: +1-805-578-4421
Email: Ron.Bergman@rpsa.ricoh.com
Mike Fenelon (Microsoft)
Email: mfenelon@microsoft.com
Ira McDonald (High North)
Phone: +1-906-494-2434
Email: imcdonald@sharplabs.com
Ivan Pavicevic (Microsoft)
Email: ivanp@microsoft.com
Send comments using the Printer MIB Project (PMP) Mailing List:
pmp@pwg.org
To subscribe, see the PWG web page:
http://www.pwg.org/"
DESCRIPTION
"The MIB module for printer port monitor support.
Copyright (C) IEEE/ISTO PWG (2005)."
REVISION "200510250000Z"
DESCRIPTION
"PWG Approved Version, PWG 5107.1-2005"
::= { enterprises pwg(2699) mibs(1) ppmMIB(2) }
ppmMIBObjects OBJECT IDENTIFIER ::= { ppmMIB 1 }
ppmMIBConformance OBJECT IDENTIFIER ::= { ppmMIB 2 }
ppmMIBObjectGroups OBJECT IDENTIFIER ::= { ppmMIBConformance 2 }
--
-- Object Definitions
--
ppmGeneral OBJECT IDENTIFIER ::= { ppmMIBObjects 1 }
ppmGeneralNaturalLanguage OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..63))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The natural language tag (RFC 3066), specified in US-ASCII, for
all localized text string objects defined in this MIB (syntax of
'SnmpAdminString'), or the empty string if not specified. For
example, 'fr-CH' (French as written in Switzerland).
Compatibility Note: At the time of publication of this MIB,
language tags are restricted to US-ASCII. In order to support
possible future evolution of languages tags (in a successor to
RFC 3066) to allow non-ASCII characters, this object has been
defined with a syntax of UTF-8 (RFC 3629).
This natural language tag is necessary for support of correct
glyph selection for text display, for support of text-to-
speech, for support of correct sorting of text values, etc.
If this object is empty, then the natural language for all
localized text string objects in this MIB MUST default to
'en-US' (US English)."
REFERENCE
"prtGeneralCurrentLocalization in IETF Printer MIB (RFC
1759/3805).
jobNaturalLanguageTag in IETF Job Monitoring MIB (RFC 2707)."
DEFVAL { ''H } -- no natural language tag
::= { ppmGeneral 1 }
ppmGeneralNumberOfPrinters OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of printers supported on this network system,
i.e., the number of entries in the 'ppmPrinterTable' below, or
zero if no printers are currently configured."
DEFVAL { 0 } -- no printers configured
::= { ppmGeneral 2 }
ppmGeneralNumberOfPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of printer ports supported on this network system,
i.e., the number of entries in the 'ppmPortTable' below, or
zero if no printer ports are currently configured."
DEFVAL { 0 } -- no printer ports configured
::= { ppmGeneral 3 }
ppmPrinter OBJECT IDENTIFIER ::= { ppmMIBObjects 2 }
ppmPrinterTable OBJECT-TYPE
SYNTAX SEQUENCE OF PpmPrinterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing a list of printers configured on this
network system, especially for use by operating systems to
facilitate selection and automatic installation of device
drivers."
::= { ppmPrinter 1 }
ppmPrinterEntry OBJECT-TYPE
SYNTAX PpmPrinterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing one printer configured on this
network system, especially for use by operating systems to
facilitate selection and automatic installation of device
drivers."
INDEX { ppmPrinterIndex }
::= { ppmPrinterTable 1 }
PpmPrinterEntry ::= SEQUENCE {
ppmPrinterIndex Integer32,
ppmPrinterName SnmpAdminString,
ppmPrinterIEEE1284DeviceId OCTET STRING,
ppmPrinterNumberOfPorts Gauge32,
ppmPrinterPreferredPortIndex Integer32,
ppmPrinterHrDeviceIndex Integer32,
ppmPrinterSnmpCommunityName OCTET STRING,
ppmPrinterSnmpQueryEnabled TruthValue
}
ppmPrinterIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A locally unique identifier for this network printer. The
value of this object SHOULD be preserved (for each printer)
across reboots and administrative configuration changes.
If the value of 'ppmPortEnabled' is 'false' for all supported
ports (i.e., ports with the same value of 'ppmPrinterIndex'),
then applications MUST NOT attempt installation of this printer.
Per SMIv2 (RFC 2578), the DEFVAL clause has been omitted on this
'not-accessible' index object."
::= { ppmPrinterEntry 1 }
ppmPrinterName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user friendly name for this printer that may be used to
facilitate user selection of a printer supported by a network
system, in the locale specified by 'ppmGeneralNaturalLanguage'.
This printer name may contain non-ASCII characters that are NOT
allowed in a URI (RFC 3986) without percent-encoding.
Systems that implement the IETF Printer MIB v1 (RFC 1759) SHOULD
implement this object as an augmentation to the Printer MIB v1.
Systems that implement the IETF Printer MIB v2 (RFC 3805) MUST
ensure that the value of this object is identical to the value
of 'prtGeneralPrinterName' for each printer.
The value of this object SHOULD be unique across all printers on
this network system and SHOULD be meaningful to end users
(e.g., 'PrinterXYZ').
The value of this object SHOULD be set by an out-of-band method
(e.g., local console) during installation (by the vendor or site
administrator) and SHOULD NOT be subsequently modified, so that
the value can be used as a static key for access to the printer.
The charset of this text string object is UTF-8 (RFC 3629), in
order to support names that cannot be represented in US-ASCII."
REFERENCE
"prtGeneralPrinterName in IETF Printer MIB v2 (RFC 3805).
printer-name in IPP/1.1 (RFC 2911)."
DEFVAL { ''H } -- printer name not specified
::= { ppmPrinterEntry 2 }
ppmPrinterIEEE1284DeviceId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1023))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IEEE 1284 device ID for this printer, a set of capabilities
(keys and values) specified in the US-ASCII charset and the
format 'key1: value {, value }; ... keyN: value {,value };',
as follows:
(a) SPACE (0x20), TAB (0x09), VTAB (0x0B), CR (0x0D), NL (0x0A),
and FF (0x0C) are allowed, but are ignored when parsing
(b) other control characters (less than 0x20) MUST NOT be used
(c) COLON (0x3A), COMMA (0x2C), and SEMICOLON (0x3B) are used as
delimiters and MUST NOT be included in any key or value
(d) each key MUST be separated from value(s) using COLON (0x3A)
(e) multiple values MUST BE separated using COMMA (0x2C)
(f) each capability MUST BE terminated using SEMICOLON (0x3B)
(g) all printers MUST include the following capabilities
- MANUFACTURER (or abbreviation MFG)
- MODEL (or abbreviation MDL)
(h) all printers MAY include the following capabilities
- COMMAND SET (or abbreviation CMD)
- COMMENT
- ACTIVE COMMAND SET
For example (actually all on one line of text):
MANUFACTURER:ACME Manufacturing;
COMMAND SET:PCL,PJL,PS,XHTML-Print+xml;
MODEL:LaserBeam 9;
COMMENT:Anything you like;
ACTIVE COMMAND SET:PCL;
The value of this object MUST exactly match the IEEE 1284-2000
Device ID string, except that the length field MUST NOT be
specified. The value MUST be assigned by the Printer vendor
and MUST NOT be localized by the Print Service.
Compatibility Note: At the time of publication of this MIB,
IEEE device IDs are restricted to US-ASCII. In order to support
possible future evolution of IEEE device IDs (in a successor to
IEEE 1284-2000) to allow non-ASCII characters, this object has
been defined with a syntax of OCTET STRING to support the future
use of UTF-8 (RFC 3629).
If this object is empty, then the value of 'ppmPortProtocolType'
for the selected port SHOULD be used to load a generic driver."
REFERENCE
"Section 7.6 of IEEE 1284-2000.
printer-make-and-model in IPP/1.1 (RFC 2911)."
DEFVAL { ''H } -- no IEEE 1284 device ID
::= { ppmPrinterEntry 3 }
ppmPrinterNumberOfPorts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of printer ports supported on this network printer,
i.e., the number of entries in the 'ppmPortTable' below with a
first index of 'ppmPrinterIndex', or zero if no printer ports
are currently configured."
DEFVAL { 0 } -- no printer ports configured
::= { ppmPrinterEntry 4 }
ppmPrinterPreferredPortIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of 'ppmPortIndex' for the preferred port for this
printer (configured by vendor or site administrator), or zero if
not specified.
Compatibility Note: The value of zero is NOT valid for
'ppmPortIndex'. It is an out-of-band value.
If this object is non-zero, then installation applications
SHOULD default to this port in their user interface dialogue."
REFERENCE
"document-format-default in IPP/1.1 (RFC 2911)."
DEFVAL { 0 } -- no preferred port configured
::= { ppmPrinterEntry 5 }
ppmPrinterHrDeviceIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of 'hrDeviceIndex' in the IETF Host Resources MIB
(RFC 1514/2790), or zero if not specified. This value of
'hrDeviceIndex' MAY be used for status queries for this printer
if the value of 'ppmPrinterSnmpQueryEnabled' is 'true'.
Compatibility Note: The value of zero is NOT valid for
'hrDeviceIndex'. It is an out-of-band value.
If this object is zero, then monitoring applications MUST NOT
attempt status queries for this printer in the IETF Host
Resources MIB (RFC 1514/2790) and/or IETF Printer MIB
(RFC 1759/3805)."
REFERENCE
"hrDeviceStatus, hrPrinterStatus, hrPrinterDetectedErrorState
in IETF Host Resources MIB (RFC 1514/2790).
Section 2.2.13.2 'Overall Printer Status' and
Appendix E 'Overall Printer Status Table' in IETF Printer MIB v2
(RFC 3805)."
DEFVAL { 0 } -- no host device index
::= { ppmPrinterEntry 6 }
ppmPrinterSnmpCommunityName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP read community name, an opaque binary string, for
access to status information in IETF Host Resources MIB (RFC
1514/2790) and IETF Printer MIB (RFC 1759/3805) for this printer
via the value of 'ppmPrinterHrDeviceIndex' (i.e., a 'MIB view'
of these two MIBs).
Security Warning: Due to the widespread availability of free
'packet sniffers' (network traffic snooping applications) and
SNMP packet decoders, SNMP community names no longer offer even
weak security. This object SHOULD only be used to support 'MIB
views'. Implementations SHOULD use SNMPv3 security to protect
network resources from unauthorized monitoring.
If this object is empty, then the SNMP read community name for
this printer (if any) SHOULD default to 'public' in US-ASCII."
REFERENCE
"snmpCommunityName in IETF SNMP Community MIB (RFC 3584)."
DEFVAL { ''H } -- no SNMP read community name
::= { ppmPrinterEntry 7 }
ppmPrinterSnmpQueryEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status query mode for this printer, for queries by
monitoring applications in the IETF Host Resources MIB
(RFC 1514/2790) and/or IETF Printer MIB (RFC 1759/3805).
If this object is 'true', then monitoring applications MAY
attempt status queries for this printer in the IETF Host
Resources MIB and/or IETF Printer MIB.
If this object is 'false', then monitoring applications MUST
NOT attempt status queries for this printer in the IETF Host
Resources MIB and/or IETF Printer MIB."
REFERENCE
"ppmPrinterSnmpCommunityName."
DEFVAL { false } -- SNMP status queries disabled
::= { ppmPrinterEntry 8 }
ppmPort OBJECT IDENTIFIER ::= { ppmMIBObjects 3 }
ppmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF PpmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing a list of input printer ports configured on
this network system, especially for use by operating systems to
facilitate selection and automatic installation of device
drivers."
REFERENCE
"ppmPrinterTable."
::= { ppmPort 1 }
ppmPortEntry OBJECT-TYPE
SYNTAX PpmPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing one input printer port configured on
this network system, especially for use by operating systems to
facilitate selection and automatic installation of device
drivers."
REFERENCE
"ppmPrinterEntry."
INDEX { ppmPrinterIndex, ppmPortIndex }
::= { ppmPortTable 1 }
PpmPortEntry ::= SEQUENCE {
ppmPortIndex Integer32,
ppmPortEnabled TruthValue,
ppmPortName SnmpAdminString,
ppmPortServiceNameOrURI SnmpAdminString,
ppmPortProtocolType Integer32,
ppmPortProtocolTargetPort Integer32,
ppmPortProtocolAltSourceEnabled TruthValue,
ppmPortPrtChannelIndex Integer32,
ppmPortLprByteCountEnabled TruthValue
}
ppmPortIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A locally unique identifier for this printer port when appended
to the value of 'ppmPrinterIndex' for this printer port. The
value of this object SHOULD be preserved (for each port) across
reboots and administrative configuration changes.
Per SMIv2 (RFC 2578), the DEFVAL clause has been omitted on this
'not-accessible' index object."
::= { ppmPortEntry 1 }
ppmPortEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current administrative configuration mode for this port.
If this object is 'false', then applications MUST NOT attempt
installation of this port and SHOULD NOT attempt print job
submission to this port.
If this object is 'true', then the port is currently enabled.
If this object is 'false', then the port is currently disabled."
REFERENCE
"ppmPortProtocolType and ppmPortHrDeviceIndex."
DEFVAL { false } -- port disabled
::= { ppmPortEntry 2 }
ppmPortName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A user friendly name for this port that may be used to
facilitate user selection of a port on a multi-port network
system, in the locale specified by 'ppmGeneralNaturalLanguage'.
This port name may contain non-ASCII characters that are NOT
allowed in a URI (RFC 3986) without percent-encoding.
The value of this object SHOULD be unique across all ports on
this network system and SHOULD be meaningful to end users
(e.g., 'PrinterXYZ-LPR-Duplex').
The value of this object SHOULD be set by an out-of-band method
(e.g., local console) during installation (by the vendor or site
administrator) and SHOULD NOT be subsequently modified, so that
the value can be used as a static key for access to the port.
The charset of this text string object is UTF-8 (RFC 3629), in
order to support names that cannot be represented in US-ASCII."
REFERENCE
"prtChannelInformation in IETF Printer MIB v2 (RFC 3805)."
DEFVAL { ''H } -- port name not specified
::= { ppmPortEntry 3 }
ppmPortServiceNameOrURI OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The service name or URI for this port, specified in UTF-8 (RFC
3629), in the locale specified by 'ppmGeneralNaturalLanguage'.
The service name is typically a queue name.
Compatibility Note: At the time of publication of this MIB,
the Microsoft tools do not support LPR queue names longer than
32 characters. Network administrators SHOULD NOT assign longer
LPR queue names, to prevent interworking problems.
Compatibility Note: At the time of publication of this MIB,
IETF URI Generic Syntax (RFC 3986) requires that all non-ASCII
characters be percent-encoded, while IETF Internationalized
Resource Identifiers (RFC 3987) permits native UTF-8 resource
identifiers and supplies mappings to and from standard URI.
In order to support current use of IRI and possible future
evolution of URI (in a successor to RFC 3986) to allow non-ASCII
characters, this object has been defined with a syntax of UTF-8
(RFC 3629).
Examples of well-formed service URI for print protocols
include:
- 'lpr://foo.example.com/public-printer' (where 'public-
printer' is the LPR queue name portion)
and
- 'ipp://bar.example.com/printer/fox'
If this object is non-empty, then it SHOULD NOT conflict with a
the default (e.g., IANA-registered) or explicit transport target
port specified in 'ppmPortProtocolTargetPort'. In case of
conflict, the URI value in 'ppmPortServiceNameOrURI' is
authoritative (e.g., 'ipp://example.com:631/~smith/printer').
If this object is empty and 'ppmPortProtocolType' is
'chLPDServer(8)', the LPR queue name MUST default to 'LPR'."
REFERENCE
"IETF Line Printer Daemon Protocol (RFC 1179).
'lpr:' URL scheme in IANA-registered SLP Printer Schema at
http://www.iana.org/assignments/svrloc-templates/
printer-uri in LDAP Printer Schema (RFC 3712).
IPP/1.1: IPP URL Scheme (RFC 3510).
printer-uri-supported in IPP/1.1 (RFC 2911)."
DEFVAL { ''H } -- no service name or URI
::= { ppmPortEntry 4 }
ppmPortProtocolType OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protocol type of this printer port, specified as a value
from 'PrtChannelTypeTC' in the IANA Printer MIB (e.g.,
'chLPDServer(8)' for LPR (RFC 1179) or 'chPort9100(11)' for
Raw), or zero if not specified.
Compatibility Note: The value of zero is NOT registered in the
IANA Printer MIB. It is an out-of-band value. Thus the syntax
of this object is NOT specified as 'PrtChannelTypeTC'.
Systems that do NOT implement IETF Printer MIB v2 (RFC 3805)
SHOULD use 'chPort9100(11)' for Raw printing (with an alternate
port in 'ppmPortProtocolTargetPort', if necessary), because
'chPortTCP(37)' and 'chBidirPortTCP(38)' are NOT defined in
IETF Printer MIB v1 (RFC 1759).
Systems that do implement the IETF Printer MIB v2 (RFC 3805)
MAY instead use 'chPortTCP(37)' or 'chBidirPortTCP(38)' for Raw
printing, because 'chPort9100(11)' is DEPRECATED in IETF
Printer MIB v2.
Systems that implement any version of the IETF Printer MIB
(RFC 1759/3805) SHOULD use the same value of protocol type for
this port in the 'prtChannelTable', so monitoring applications
MAY search for more channel information and status."
REFERENCE
"PrtChannelTypeTC in IANA Printer MIB (RFC 3805 and
http://www.iana.org/assignments/ianaprinter-mib).
prtChannelType in IETF Printer MIB (RFC 1759/3805)."
DEFVAL { 0 } -- protocol type not specified
::= { ppmPortEntry 5 }
ppmPortProtocolTargetPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transport (TCP, UDP, etc.) target port number for this
protocol, i.e., an alternate port from the protocol default, or
zero if not specified (use protocol default). This object MAY
be used for any print protocol (from the Internet, NetWare,
AppleTalk, or other protocol suite).
If this object is zero, then the actual target port number is
the default port for the specified 'ppmPortProtocolType' (e.g.,
'chPort9100(11)' uses '9100').
If this object is non-zero, then it SHOULD NOT conflict with the
default (e.g., IANA-registered) target port implied by the value
of 'ppmPortProtocolType' or the explicit transport target port
specified in 'ppmPortServiceNameOrURI'. In case of conflict,
the URI value in 'ppmPortServiceNameOrURI' is authoritative
(e.g., 'ipp://example.com:631/~smith/printer').
If 'ppmPortProtocolType' is 'chLPDServer(8)', then this object
MUST be ignored (because LPR target port is fixed at '515')."
REFERENCE
"IETF Line Printer Daemon Protocol (RFC 1179)."
DEFVAL { 0 } -- target port not specified
::= { ppmPortEntry 6 }
ppmPortProtocolAltSourceEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alternate transport source port mode for this protocol.
If this object is 'true', then transport source ports outside
the standard range MAY be used (e.g., LPR source port standard
range is defined in RFC 1179 to be '721' to '731', inclusive).
If this object is 'false', then transport source ports outside
the standard range MUST NOT be used (to avoid protocol
errors)."
REFERENCE
"IETF Line Printer Daemon Protocol (RFC 1179)."
DEFVAL { false } -- alt source ports disabled
::= { ppmPortEntry 7 }
ppmPortPrtChannelIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of 'prtChannelIndex' in IETF Printer MIB
(RFC 1759/3805) that corresponds to this printer port, or zero
if not specified.
Compatibility Note: The value of zero is NOT valid for
'prtChannelIndex'. It is an out-of-band value.
Systems that implement any version of the IETF Printer MIB
(RFC 1759/3805) SHOULD correctly implement this object, so
monitoring applications MAY search for print channel information
and status.
If this object is zero, then monitoring applications MUST NOT
attempt print channel status queries for this printer port."
REFERENCE
"prtChannelIndex, prtChannelIfIndex, prtChannelState, and
prtChannelStatus in IETF Printer MIB (RFC 1759/3805)."
DEFVAL { 0 } -- no print channel index
::= { ppmPortEntry 8 }
ppmPortLprByteCountEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current LPR byte counting mode for this port if applicable.
If the value of 'ppmPortProtocolType' is NOT 'chLPDServer(8)',
then monitoring applications MUST ignore the value of this
object.
If this object is 'true', then LPR byte counting is enabled.
If this object is 'false', then LPR byte counting is disabled."
REFERENCE
"IETF Line Printer Daemon Protocol (RFC 1179)."
DEFVAL { false } -- LPR byte counting disabled
::= { ppmPortEntry 9 }
--
-- Conformance
--
ppmMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statements for SNMP Agents that implement this
Printer Port Monitor MIB."
MODULE -- this module
MANDATORY-GROUPS { ppmGeneralGroup, ppmPrinterGroup, ppmPortGroup }
OBJECT ppmPrinterIEEE1284DeviceId
SYNTAX OCTET STRING (SIZE(0..255))
DESCRIPTION
"At least 255 octets maximum string length MUST be supported
by all implementations of this object. The 'MANUFACTURER' (or
'MFG') and 'MODEL' (or 'MDL') fields MUST be contained within
the first 255 octets of this object (to prevent truncation of
critical information across gateways and mid-level managers).
Implementations that support less than the 1023 octets maximum
string length MUST only truncate complete fields (i.e., keyword,
colon, value(s), and semicolon)."
::= { ppmMIBConformance 1 }
--
-- Conformance Groups
--
ppmGeneralGroup OBJECT-GROUP
OBJECTS {
ppmGeneralNaturalLanguage,
ppmGeneralNumberOfPrinters,
ppmGeneralNumberOfPorts
}
STATUS current
DESCRIPTION
"The General object group in the Printer Port Monitor MIB"
::= { ppmMIBObjectGroups 1 }
ppmPrinterGroup OBJECT-GROUP
OBJECTS {
ppmPrinterName,
ppmPrinterIEEE1284DeviceId,
ppmPrinterNumberOfPorts,
ppmPrinterPreferredPortIndex,
ppmPrinterHrDeviceIndex,
ppmPrinterSnmpCommunityName,
ppmPrinterSnmpQueryEnabled
}
STATUS current
DESCRIPTION
"The Printer object group in the Printer Port Monitor MIB"
::= { ppmMIBObjectGroups 2 }
ppmPortGroup OBJECT-GROUP
OBJECTS {
ppmPortEnabled,
ppmPortName,
ppmPortServiceNameOrURI,
ppmPortProtocolType,
ppmPortProtocolTargetPort,
ppmPortProtocolAltSourceEnabled,
ppmPortPrtChannelIndex,
ppmPortLprByteCountEnabled
}
STATUS current
DESCRIPTION
"The Port object group in the Printer Port Monitor MIB"
::= { ppmMIBObjectGroups 3 }