Observium_CE/mibs/rfc/MPLS-OAM-ID-STD-MIB

967 lines
34 KiB
Plaintext

MPLS-OAM-ID-STD-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI -- RFC 2578
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF -- RFC 2580
RowStatus, RowPointer, StorageType
FROM SNMPv2-TC -- RFC 2579
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB -- RFC 3411
IndexIntegerNextFree
FROM DIFFSERV-MIB -- RFC 3289
mplsStdMIB
FROM MPLS-TC-STD-MIB -- RFC 3811
InterfaceIndexOrZero, ifGeneralInformationGroup,
ifCounterDiscontinuityGroup
FROM IF-MIB; -- RFC 2863
mplsOamIdStdMIB MODULE-IDENTITY
LAST-UPDATED
"201601070000Z" -- January 07, 2016
ORGANIZATION
"Multiprotocol Label Switching (MPLS) Working Group"
CONTACT-INFO
"Sam Aldrin
Google, Inc.
1600 Amphitheatre Parkway
Mountain View, CA 94043
USA
Email: aldrin.ietf@gmail.com
Thomas D. Nadeau
Email: tnadeau@lucidvision.com
Venkatesan Mahalingam
Dell, Inc.
5450 Great America Parkway
Santa Clara, CA 95054
USA
Email: venkat.mahalingams@gmail.com
Kannan KV Sampath
Redeem
India
Email: kannankvs@gmail.com
Ping Pan
Infinera
Sami Boutros
VMware, Inc.
3401 Hillview Ave.
Palo Alto, CA 94304
USA
Email: sboutros@vmware.com"
DESCRIPTION
"Copyright (c) 2016 IETF Trust and the persons identified
as authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or
without modification, is permitted pursuant to, and subject
to the license terms contained in, the Simplified BSD
License set forth in Section 4.c of the IETF Trust's
Legal Provisions Relating to IETF Documents
(http://trustee.ietf.org/license-info).
This MIB module contains generic object definitions for
MPLS OAM identifiers."
-- Revision history
REVISION
"201601070000Z" -- January 07, 2016
DESCRIPTION
"MPLS OAM Identifiers MIB objects for Tunnels, LSPs,
Pseudowires, and Sections."
::= { mplsStdMIB 21 }
-- Top-level components of this MIB module
-- notifications
mplsOamIdNotifications
OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 0 }
-- tables, scalars
mplsOamIdObjects OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 1 }
-- conformance
mplsOamIdConformance
OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 2 }
-- Start of MPLS Transport Profile MEG table
mplsOamIdMegIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsOamIdMegIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsOamIdMegIndex."
::= { mplsOamIdObjects 1 }
mplsOamIdMegTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsOamIdMegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the Maintenance
Entity Groups (MEGs).
A MEG, as mentioned in the MPLS-TP OAM framework, defines
a set of one or more Maintenance Entities (MEs).
MEs define a relationship between any two points of a
transport path in an OAM domain to which maintenance and
monitoring operations apply."
::= { mplsOamIdObjects 2 }
mplsOamIdMegEntry OBJECT-TYPE
SYNTAX MplsOamIdMegEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS-TP MEG.
An entry can be created by a network administrator
or by an SNMP agent as instructed by an MPLS-TP OAM
framework.
When a new entry is created with
mplsOamIdMegOperatorType set to ipCompatible (1),
then as per RFC 6370 (MEG_ID for an LSP is LSP_ID, and
MEG_ID for a PW is PW_Path_ID), MEP_ID can be
automatically formed.
For a co-routed bidirectional LSP, MEG_ID is
A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
Node_ID::Tunnel_Num}::LSP_Num.
For an associated bidirectional LSP, MEG_ID is
A1-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}::
Z9-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}.
For an LSP, MEP_ID is formed using
Global_ID::Node_ID::Tunnel_Num::LSP_Num.
For a PW, MEG_ID is formed using AGI::
A1-{Global_ID::Node_ID::AC_ID}::
Z9-{Global_ID::Node_ID::AC_ID}.
For a PW, MEP_ID is formed using
AGI::Global_ID::Node_ID::AC_ID.
MEP_ID is retrieved from the mplsOamIdMegServicePointer
object based on the mplsOamIdMegServicePointerType value.
The ICC MEG_ID for an LSP and a PW is formed using the
objects mplsOamIdMegIdIcc and mplsOamIdMegIdUmc.
MEP_ID can be formed using MEG_ID::MEP_Index."
REFERENCE
"1. RFC 5860: Requirements for Operations, Administration,
and Maintenance (OAM) in MPLS Transport Networks,
May 2010.
2. RFC 6371: Operations, Administration, and Maintenance
Framework for MPLS-Based Transport Networks,
September 2011, Section 3.
3. RFC 6370: MPLS Transport Profile (MPLS-TP) Identifiers,
September 2011.
4. RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
Following ITU-T Conventions, May 2013."
INDEX { mplsOamIdMegIndex }
::= { mplsOamIdMegTable 1 }
MplsOamIdMegEntry ::= SEQUENCE {
mplsOamIdMegIndex Unsigned32,
mplsOamIdMegName SnmpAdminString,
mplsOamIdMegOperatorType INTEGER,
mplsOamIdMegIdCc SnmpAdminString,
mplsOamIdMegIdIcc SnmpAdminString,
mplsOamIdMegIdUmc SnmpAdminString,
mplsOamIdMegServicePointerType INTEGER,
mplsOamIdMegMpLocation INTEGER,
mplsOamIdMegPathFlow INTEGER,
mplsOamIdMegOperStatus INTEGER,
mplsOamIdMegSubOperStatus BITS,
mplsOamIdMegRowStatus RowStatus,
mplsOamIdMegStorageType StorageType
}
mplsOamIdMegIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index for the conceptual row identifying a MEG within
this MEG table. Managers should obtain new values for row
creation in this table by reading mplsOamIdMegIndexNext."
::= { mplsOamIdMegEntry 1 }
mplsOamIdMegName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..48))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Each MEG has a unique name amongst all those used or
available to a service provider or operator. It
facilitates easy identification of administrative
responsibility for each MEG."
::= { mplsOamIdMegEntry 2 }
mplsOamIdMegOperatorType OBJECT-TYPE
SYNTAX INTEGER {
ipCompatible (1),
iccBased (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the operator type for the MEG. Conceptual rows
having 'iccBased' as the operator type MUST have valid
values for the objects mplsOamIdMegIdIcc and
mplsOamIdMegIdUmc when the row status is active."
REFERENCE
"1. RFC 6370: MPLS Transport Profile (MPLS-TP) Identifiers,
September 2011.
2. RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
Following ITU-T Conventions, May 2013, Section 3.1."
DEFVAL { ipCompatible }
::= { mplsOamIdMegEntry 3 }
mplsOamIdMegIdCc OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..2))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Global uniqueness is assured by concatenating the ICC
with a Country Code (CC). The Country Code (alpha-2)
is a string of two alphabetic characters represented
with uppercase letters (i.e., A-Z).
This object MUST contain a non-null value if
the MplsOamIdMegOperatorType value is iccBased (2);
otherwise, a null value with octet size 0
should be assigned."
REFERENCE
"RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
Following ITU-T Conventions, May 2013, Section 3."
DEFVAL {""}
::= { mplsOamIdMegEntry 4 }
mplsOamIdMegIdIcc OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Unique code assigned to a network operator or service
provider; maintained by the ITU-T. This is the
ITU Carrier Code used to form the MEGID.
This object MUST contain a non-null value if
the MplsOamIdMegOperatorType value is iccBased (2);
otherwise, a null value with octet size 0
should be assigned."
REFERENCE
"RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
Following ITU-T Conventions, May 2013, Section 3.1."
DEFVAL {""}
::= { mplsOamIdMegEntry 5 }
mplsOamIdMegIdUmc OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..7))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Unique code assigned by a network operator or service
provider. This code is appended to mplsOamIdMegIdIcc to
form the MEGID.
This object MUST contain a non-null value if
the MplsOamIdMegOperatorType value is iccBased (2);
otherwise, a null value with octet size 0
should be assigned."
REFERENCE
"RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
Following ITU-T Conventions, May 2013, Section 7.1."
DEFVAL {""}
::= { mplsOamIdMegEntry 6 }
mplsOamIdMegServicePointerType OBJECT-TYPE
SYNTAX INTEGER {
tunnel (1),
lsp (2),
pseudowire (3),
section (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the service type for the MEG.
If the service type indicates tunnel (1), the service
pointer in the mplsOamIdMeTable points to an entry in
the point-to-point mplsTunnelTable (RFC 3812).
If the service type indicates lsp (2), the service pointer
in the mplsOamIdMeTable points to an entry in
the co-routed or associated bidirectional mplsTunnelTable.
If the value is the pseudowire (3) service type, the
service pointer in the mplsOamIdMeTable points to an entry
in the pwTable (RFC 5601).
If the value is the section (4) service type, the service
pointer in the mplsOamIdMeTable points to an entry in
the mplsTunnelTable (RFC 3812)."
REFERENCE
"1. RFC 3812: Multiprotocol Label Switching (MPLS)
Traffic Engineering (TE) Management Information
Base (MIB), June 2004.
2. RFC 5601: Pseudowire (PW) Management Information
Base (MIB), July 2009."
DEFVAL { lsp }
::= { mplsOamIdMegEntry 7 }
mplsOamIdMegMpLocation OBJECT-TYPE
SYNTAX INTEGER {
perNode (1),
perInterface (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the MP location type for this MEG.
If the value is perNode, then the MEG in the LSR supports
only perNode MEPs/MIPs, i.e., only one MEP/MIP in an LSR.
If the value is perInterface, then the MEG in the LSR
supports perInterface MEPs/MIPs, i.e., two MEPs/MIPs in
an LSR."
REFERENCE
"RFC 6371: Operations, Administration, and Maintenance
Framework for MPLS-Based Transport Networks,
September 2011."
DEFVAL { perNode }
::= { mplsOamIdMegEntry 8 }
mplsOamIdMegPathFlow OBJECT-TYPE
SYNTAX INTEGER {
unidirectionalPointToPoint (1),
coRoutedBidirectionalPointToPoint (2),
associatedBidirectionalPointToPoint (3),
unidirectionalPointToMultiPoint (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the transport path flow for this MEG.
In the case of a unidirectional point-to-point transport
path, a single unidirectional ME is defined to monitor it.
In the case of associated bidirectional point-to-point
transport paths, two independent unidirectional MEs are
defined to independently monitor each direction.
In the case of co-routed bidirectional point-to-point
transport paths, a single bidirectional ME is defined to
monitor both directions congruently.
In the case of unidirectional point-to-multipoint transport
paths, a single unidirectional ME for each leaf is defined
to monitor the transport path from the root to that leaf."
REFERENCE
"RFC 6371: Operations, Administration, and Maintenance
Framework for MPLS-Based Transport Networks,
September 2011."
DEFVAL { coRoutedBidirectionalPointToPoint }
::= { mplsOamIdMegEntry 9 }
mplsOamIdMegOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the operational status of the
Maintenance Entity Group (MEG). This object is used to
send the notification to the SNMP manager about the MEG.
The value up (1) indicates that the MEG and its monitored
path are operationally up. The value down (2) indicates
that the MEG is operationally down.
When the value of mplsOamIdMegOperStatus is up (1),
all the bits of mplsOamIdMegSubOperStatus must be cleared.
When the value of mplsOamIdMegOperStatus is down (2),
at least one bit of mplsOamIdMegSubOperStatus must be set."
::= { mplsOamIdMegEntry 10 }
mplsOamIdMegSubOperStatus OBJECT-TYPE
SYNTAX BITS {
megDown (0),
meDown (1),
oamAppDown (2),
pathDown (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the reason why the MEG operational
status, as indicated by the object mplsOamIdMegOperStatus,
is down. This object is used to send the notification to
the SNMP manager about the MEG.
The bit 0 (megDown) indicates that the MEG is down.
The bit 1 (meDown) indicates that the ME table is down.
The bit 2 (oamAppDown) indicates that the OAM application
(LSP or PW) monitored by this MEG is down. Currently, BFD
is the only supported OAM application.
The bit 3 (pathDown) indicates that the underlying
LSP or PW is down."
::= { mplsOamIdMegEntry 11 }
mplsOamIdMegRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or delete
a row in this table. When a row in this table is in the
active(1) state, no objects in that row can be modified
by the agent except mplsOamIdMegRowStatus."
::= { mplsOamIdMegEntry 12 }
mplsOamIdMegStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this
object.
Conceptual rows having the value 'permanent'
need not allow write access to any columnar
objects in the row."
DEFVAL { volatile }
::= { mplsOamIdMegEntry 13 }
-- End of MPLS Transport Profile MEG table
-- Start of MPLS Transport Profile ME table
mplsOamIdMeIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsOamIdMeIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsOamIdMeIndex."
::= { mplsOamIdObjects 3 }
mplsOamIdMeMpIndexNext OBJECT-TYPE
SYNTAX IndexIntegerNextFree (0..4294967295)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an unused value for
mplsOamIdMeMpIndex, or a zero to indicate
that none exist. Negative values are not allowed,
as they do not correspond to valid values of
mplsOamIdMeMpIndex."
::= { mplsOamIdObjects 4 }
mplsOamIdMeTable OBJECT-TYPE
SYNTAX SEQUENCE OF MplsOamIdMeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains MPLS-TP ME information.
The ME is some portion of a transport path that requires
management bounded by two points (called MEPs), and the
relationship between those points to which maintenance
and monitoring operations apply.
This table is generic enough to handle MEP and MIP
information within a MEG."
::= { mplsOamIdObjects 5 }
mplsOamIdMeEntry OBJECT-TYPE
SYNTAX MplsOamIdMeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in this table represents an MPLS-TP ME. This
entry represents the ME if the source and sink MEPs are
defined.
An ME is a point-to-point entity. One ME has two such
MEPs. A MEG is a group of one or more MEs. One MEG can
have two or more MEPs.
For a point-to-point LSP, one MEG has one ME, and this ME
is associated with two MEPs (source and sink MEPs) within
a MEG. Each mplsOamIdMeIndex value denotes the ME within
a MEG.
In the case of unidirectional point-to-point transport
paths, a single unidirectional ME is defined to monitor
it, and mplsOamIdMeServicePointer points to a
unidirectional point-to-point path.
In the case of associated bidirectional point-to-point
transport paths, two independent unidirectional
MEs are defined to independently monitor each direction,
and each mplsOamIdMeServicePointer MIB object points to a
unique unidirectional transport path.
This has implications for transactions that terminate at
or query a MIP, as a return path from a MIP to a source
MEP does not necessarily exist within the MEG.
In the case of co-routed bidirectional point-to-point
transport paths, a single bidirectional ME is defined to
monitor both directions congruently, and the
mplsOamIdMeServicePointer MIB object points to a co-routed
bidirectional point-to-point transport path.
In the case of unidirectional point-to-multipoint transport
paths, a single unidirectional ME for each leaf is defined
to monitor the transport path from the root to that leaf,
and each leaf has different transport path information in
the mplsOamIdMeServicePointer MIB object. Note that the
MplsOamIdMeEntry should be created manually once the MEG
is configured for OAM operations."
INDEX { mplsOamIdMegIndex,
mplsOamIdMeIndex,
mplsOamIdMeMpIndex
}
::= { mplsOamIdMeTable 1 }
MplsOamIdMeEntry ::= SEQUENCE {
mplsOamIdMeIndex Unsigned32,
mplsOamIdMeMpIndex Unsigned32,
mplsOamIdMeName SnmpAdminString,
mplsOamIdMeMpIfIndex InterfaceIndexOrZero,
mplsOamIdMeSourceMepIndex Unsigned32,
mplsOamIdMeSinkMepIndex Unsigned32,
mplsOamIdMeMpType INTEGER,
mplsOamIdMeMepDirection INTEGER,
mplsOamIdMeServicePointer RowPointer,
mplsOamIdMeRowStatus RowStatus,
mplsOamIdMeStorageType StorageType
}
mplsOamIdMeIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Uniquely identifies an ME index within a MEG. Managers
should obtain new values for row creation in this table by
reading mplsOamIdMeIndexNext."
::= { mplsOamIdMeEntry 1 }
mplsOamIdMeMpIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the Maintenance Point (MP) index that is used to
create multiple MEPs in a node of a single ME. The value
of this object can be the MEP index or the MIP index.
Managers should obtain new values for row creation in this
table by reading mplsOamIdMeMpIndexNext."
::= { mplsOamIdMeEntry 2 }
mplsOamIdMeName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..48))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object denotes the ME name. Each ME has a unique
name within a MEG."
::= { mplsOamIdMeEntry 3 }
mplsOamIdMeMpIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the MP interface.
If the mplsOamIdMegMpLocation object value
is perNode (1), the MP interface index should point
to the incoming interface or outgoing interface, or
be zero (to indicate that the MP OAM packets are initiated
from the forwarding engine).
If the mplsOamIdMegMpLocation object value is
perInterface (2), the MP interface index should point to
the incoming interface or outgoing interface."
REFERENCE
"1. RFC 6371: Operations, Administration, and Maintenance
Framework for MPLS-Based Transport Networks,
September 2011.
2. RFC 2863: The Interfaces Group MIB, June 2000."
DEFVAL { 0 }
::= { mplsOamIdMeEntry 4 }
mplsOamIdMeSourceMepIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the source MEP index of the ME. This object
should be configured if the mplsOamIdMegOperatorType object
in the mplsOamIdMegEntry is configured as iccBased (2).
If the MEG is configured for an IP-based operator,
the value of this object should be set to zero, and the
MEP ID will be automatically derived from the service
identifiers (MPLS-TP LSP/PW Identifier)."
DEFVAL { 0 }
::= { mplsOamIdMeEntry 5 }
mplsOamIdMeSinkMepIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the sink MEP index of the ME. This object
should be configured if the mplsOamIdMegOperatorType object
in the mplsOamIdMegEntry is configured as iccBased (2).
If the MEG is configured for an IP-based operator,
the value of this object should be set to zero, and the
MEP ID will be automatically derived from the service
identifiers (MPLS-TP LSP/PW Identifier)."
DEFVAL { 0 }
::= { mplsOamIdMeEntry 6 }
mplsOamIdMeMpType OBJECT-TYPE
SYNTAX INTEGER {
mep (1),
mip (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the MP type within the MEG.
The object should have the value mep (1) only in the
ingress or egress nodes of the transport path.
The object can have the value mip (2) in the
intermediate nodes and possibly in the egress nodes
of the transport path."
DEFVAL { mep }
::= { mplsOamIdMeEntry 7 }
mplsOamIdMeMepDirection OBJECT-TYPE
SYNTAX INTEGER {
up (1),
down (2),
notApplicable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the direction of the MEP. This object
should be configured if mplsOamIdMeMpType is configured
as mep (1); otherwise, notApplicable (3) is set."
DEFVAL { down }
::= { mplsOamIdMeEntry 8 }
mplsOamIdMeServicePointer OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable represents a pointer to the MPLS-TP
transport path. This value MUST point at an entry in the
mplsTunnelEntry if mplsOamIdMegServicePointerType
is configured as tunnel (1), lsp (2), or section (4),
or at an entry in the pwEntry if
mplsOamIdMegServicePointerType is configured
as pseudowire (3).
Note: This service pointer object is placed in the ME table
instead of the MEG table, since it will be useful in the
point-to-multipoint case, where each ME will point to
different branches of a point-to-multipoint tree."
::= { mplsOamIdMeEntry 9 }
mplsOamIdMeRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create, modify, and/or delete
a row in this table. When a row in this table is in the
active(1) state, no objects in that row can be modified
by the agent except mplsOamIdMeRowStatus."
::= { mplsOamIdMeEntry 10 }
mplsOamIdMeStorageType OBJECT-TYPE
SYNTAX StorageType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable indicates the storage type for this object.
Conceptual rows having the value 'permanent'
need not allow write access to any columnar
objects in the row."
DEFVAL { volatile }
::= { mplsOamIdMeEntry 11 }
-- End of MPLS Transport Profile ME table
-- End of MPLS-TP OAM tables
-- Notification definitions of MPLS-TP identifiers
mplsOamIdDefectCondition NOTIFICATION-TYPE
OBJECTS {
mplsOamIdMegName,
mplsOamIdMeName,
mplsOamIdMegOperStatus,
mplsOamIdMegSubOperStatus
}
STATUS current
DESCRIPTION
"This notification is sent whenever the operational
status of the MEG is changed."
::= { mplsOamIdNotifications 1 }
-- End of notifications
-- Module compliance
mplsOamIdCompliances
OBJECT IDENTIFIER ::= { mplsOamIdConformance 1 }
mplsOamIdGroups
OBJECT IDENTIFIER ::= { mplsOamIdConformance 2 }
-- Compliance requirement for fully compliant implementations
mplsOamIdModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "Compliance statement for agents that provide full
support for the MPLS-TP-OAM-STD-MIB. Such devices
can then be monitored and also be configured
using this MIB module."
MODULE IF-MIB -- The Interfaces Group MIB, RFC 2863
MANDATORY-GROUPS {
ifGeneralInformationGroup,
ifCounterDiscontinuityGroup
}
MODULE -- this module
MANDATORY-GROUPS {
mplsOamIdMegGroup,
mplsOamIdMeGroup
}
GROUP mplsOamIdNotificationObjectsGroup
DESCRIPTION "This group is only mandatory for those
implementations that can efficiently implement
the notifications contained in this group."
GROUP mplsOamIdNotificationGroup
DESCRIPTION "This group is only mandatory for those
implementations that can efficiently implement
the notifications contained in this group."
::= { mplsOamIdCompliances 1 }
-- Compliance requirement for read-only implementations
mplsOamIdModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for agents that only provide
read-only support for the MPLS-TP-OAM-STD-MIB module."
MODULE -- this module
MANDATORY-GROUPS {
mplsOamIdMegGroup,
mplsOamIdMeGroup
}
GROUP mplsOamIdNotificationObjectsGroup
DESCRIPTION "This group is only mandatory for those
implementations that can efficiently implement
the notifications contained in this group."
GROUP mplsOamIdNotificationGroup
DESCRIPTION "This group is only mandatory for those
implementations that can efficiently implement
the notifications contained in this group."
-- mplsOamIdMegTable
OBJECT mplsOamIdMegName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegOperatorType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegIdCc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegIdIcc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegIdUmc
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegServicePointerType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegMpLocation
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegPathFlow
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMegStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
-- mplsOamIdMeTable
OBJECT mplsOamIdMeName
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeMpIfIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeSourceMepIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeSinkMepIndex
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeMpType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeMepDirection
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeServicePointer
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeRowStatus
SYNTAX RowStatus { active(1) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT mplsOamIdMeStorageType
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { mplsOamIdCompliances 2 }
-- Units of conformance
mplsOamIdMegGroup OBJECT-GROUP
OBJECTS {
mplsOamIdMegIndexNext,
mplsOamIdMegName,
mplsOamIdMegOperatorType,
mplsOamIdMegIdCc,
mplsOamIdMegIdIcc,
mplsOamIdMegIdUmc,
mplsOamIdMegServicePointerType,
mplsOamIdMegMpLocation,
mplsOamIdMegOperStatus,
mplsOamIdMegSubOperStatus,
mplsOamIdMegPathFlow,
mplsOamIdMegRowStatus,
mplsOamIdMegStorageType
}
STATUS current
DESCRIPTION
"Collection of objects needed for MPLS MEG information."
::= { mplsOamIdGroups 1 }
mplsOamIdMeGroup OBJECT-GROUP
OBJECTS {
mplsOamIdMeIndexNext,
mplsOamIdMeMpIndexNext,
mplsOamIdMeName,
mplsOamIdMeMpIfIndex,
mplsOamIdMeSourceMepIndex,
mplsOamIdMeSinkMepIndex,
mplsOamIdMeMpType,
mplsOamIdMeMepDirection,
mplsOamIdMeServicePointer,
mplsOamIdMeRowStatus,
mplsOamIdMeStorageType
}
STATUS current
DESCRIPTION
"Collection of objects needed for MPLS ME information."
::= { mplsOamIdGroups 2 }
mplsOamIdNotificationObjectsGroup OBJECT-GROUP
OBJECTS {
mplsOamIdMegOperStatus,
mplsOamIdMegSubOperStatus
}
STATUS current
DESCRIPTION
"Collection of objects needed to implement notifications."
::= { mplsOamIdGroups 3 }
mplsOamIdNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
mplsOamIdDefectCondition
}
STATUS current
DESCRIPTION
"Set of notifications implemented in this module."
::= { mplsOamIdGroups 4 }
END