IEEE8021-PE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Unsigned32,
|
|
Counter64
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
MacAddress,
|
|
TEXTUAL-CONVENTION,
|
|
TimeStamp,
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
ieee802dot1mibs,
|
|
IEEE8021PbbComponentIdentifier,
|
|
IEEE8021BridgePortNumber,
|
|
IEEE8021BridgePortNumberOrZero
|
|
FROM IEEE8021-TC-MIB
|
|
PortList
|
|
FROM Q-BRIDGE-MIB;
|
|
|
|
ieee8021BridgePEMib MODULE-IDENTITY
|
|
LAST-UPDATED "201201220000Z" -- January 22, 2012, 0000Z
|
|
ORGANIZATION "IEEE 802.1 Working Group"
|
|
CONTACT-INFO
|
|
"WG-URL: http:////www.ieee802.org/1/
|
|
WG-EMail: stds-802-1-L@IEEE.ORG
|
|
|
|
Contact: Tony Jeffree
|
|
Postal: C/O IEEE 802.1 Working Group
|
|
IEEE Standards Association
|
|
445 Hoes Lane
|
|
Piscataway
|
|
NJ 08854
|
|
USA
|
|
E-mail: stds-802-1-L@IEEE.ORG"
|
|
DESCRIPTION
|
|
"The PE MIB module for managing devices that support
|
|
Bridge Port Extension.
|
|
|
|
Unless otherwise indicated, the references in this MIB
|
|
module are to IEEE Std 802.1BR-2012.
|
|
|
|
Copyright (C) IEEE.
|
|
This version of this MIB module is part of
|
|
IEEE 802.1BR-2012; see the specification itself
|
|
for full legal notices."
|
|
|
|
REVISION "201201220000Z" -- January 22, 2012, 0000Z
|
|
DESCRIPTION
|
|
"Initial version published as part of IEEE Std. 802.1BR-2012"
|
|
|
|
::= { ieee802dot1mibs 25 }
|
|
|
|
|
|
-- =============================================================
|
|
-- subtrees in the PE MIB
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePENotifications OBJECT IDENTIFIER
|
|
::= { ieee8021BridgePEMib 1 }
|
|
|
|
ieee8021BridgePEObjects OBJECT IDENTIFIER
|
|
::= { ieee8021BridgePEMib 2 }
|
|
|
|
ieee8021BridgePEConformance OBJECT IDENTIFIER
|
|
::= { ieee8021BridgePEMib 3 }
|
|
|
|
|
|
-- Textual Conventions
|
|
|
|
IEEE802BridgePEEChannelIDTC ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual convention of an E-Channel Identifier."
|
|
SYNTAX Unsigned32 (1..4194302)
|
|
|
|
IEEE802BridgePETrafficClassValueTC ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates a traffic class. Values 0-7 correspond to
|
|
traffic classes."
|
|
SYNTAX Unsigned32 (0..7)
|
|
|
|
IEEE802BridgePETrafficSelectionAlgorithmTC ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Traffic Selection Algorithm
|
|
0: Strict Priority
|
|
1: Credit-based shaper
|
|
2: Enhanced transmission selection
|
|
3-254: Reserved for furture standardization
|
|
255: Vendor specific"
|
|
SYNTAX INTEGER {
|
|
tsaStrictPriority(0),
|
|
tsaCreditBasedShaper(1),
|
|
tsaEnhancedTransmission(2),
|
|
tsaVendorSpecific(255)
|
|
}
|
|
|
|
IEEE802BridgePETrafficClassBandwidthValue ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bandwidth in percent assigned to a
|
|
traffic class."
|
|
SYNTAX Unsigned32 (0..100)
|
|
|
|
-- PE port table entry managed object
|
|
|
|
ieee8021BridgePEPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePEPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains per port information
|
|
related to Port Extension. A row is created in this
|
|
table for any port on a Controlling Bridge that is
|
|
extended using Port Extension, including those ports
|
|
that provide communication to the Port Extenders
|
|
themselves."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEObjects 1 }
|
|
|
|
ieee8021BridgePEPortEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePEPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of per port Port Extension objects."
|
|
INDEX {
|
|
ieee8021BridgePEPortComponentId,
|
|
ieee8021BridgePEPort,
|
|
ieee8021BridgePEPortType
|
|
}
|
|
::= { ieee8021BridgePEPortTable 1 }
|
|
|
|
Ieee8021BridgePEPortEntry ::= SEQUENCE {
|
|
ieee8021BridgePEPortComponentId
|
|
IEEE8021PbbComponentIdentifier,
|
|
ieee8021BridgePEPort
|
|
IEEE8021BridgePortNumber,
|
|
ieee8021BridgePEPortType
|
|
INTEGER,
|
|
ieee8021BridgePEPortUpstreamCSPAddress
|
|
MacAddress,
|
|
ieee8021BridgePEPortEcid
|
|
IEEE802BridgePEEChannelIDTC,
|
|
ieee8021BridgePEPortNumber
|
|
IEEE8021BridgePortNumberOrZero,
|
|
ieee8021BridgePECounterDiscontinuityTime
|
|
TimeStamp,
|
|
ieee8021BridgePEPortRxrqErrorsBridge
|
|
Counter64,
|
|
ieee8021BridgePEPortRxrspErrorsBridge
|
|
Counter64,
|
|
ieee8021BridgePEPortRxrqErrorsPE
|
|
Counter64,
|
|
ieee8021BridgePEPortRxrspErrorsPE
|
|
Counter64,
|
|
ieee8021BridgePEPCP
|
|
TruthValue,
|
|
ieee8021BridgePEROW
|
|
TruthValue,
|
|
ieee8021BridgePEDEI
|
|
TruthValue,
|
|
ieee8021BridgePECN
|
|
TruthValue,
|
|
ieee8021BridgePEPFC
|
|
TruthValue,
|
|
ieee8021BridgePEExtPortEChannelsSupported
|
|
Unsigned32,
|
|
ieee8021BridgePERemoteRepEChannelsSupported
|
|
Unsigned32,
|
|
ieee8021BridgePETCsSupported
|
|
Unsigned32,
|
|
ieee8021BridgePEUtVLANsSupported
|
|
Unsigned32
|
|
}
|
|
|
|
ieee8021BridgePEPortComponentId OBJECT-TYPE
|
|
SYNTAX IEEE8021PbbComponentIdentifier
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The component identifier is used to distinguish between the
|
|
multiple virtual bridge instances within a PBB. In simple
|
|
situations where there is only a single component the default
|
|
value is 1."
|
|
::= { ieee8021BridgePEPortEntry 1 }
|
|
|
|
ieee8021BridgePEPort OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number of the port for which this entry
|
|
contains bridge management information."
|
|
::= { ieee8021BridgePEPortEntry 2 }
|
|
|
|
ieee8021BridgePEPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pepCascade(1),
|
|
pepUpstream(2),
|
|
pepExtended(3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational mode of a port participating in
|
|
Port Exension. The enumerated values are:
|
|
pepCascade - the port is operating as a Cascade port
|
|
pepUpstream - the port is operating as an Upstream port
|
|
pepExtended - the port is operating as an Extended port"
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 3 }
|
|
|
|
ieee8021BridgePEPortUpstreamCSPAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address used for communication of the PE CSP
|
|
protocol of the device connected to the upstream port
|
|
of the Port Extender (which may be the Controlling
|
|
Bridge or an upstream Port Extender). This provides
|
|
the hierarchal relationship in a cascade of Port
|
|
Extenders"
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 4 }
|
|
|
|
ieee8021BridgePEPortEcid OBJECT-TYPE
|
|
SYNTAX IEEE802BridgePEEChannelIDTC
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The default ECID assigend to this port and the port
|
|
on the Port Extender to which this port corresponds."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 5 }
|
|
|
|
ieee8021BridgePEPortNumber OBJECT-TYPE
|
|
SYNTAX IEEE8021BridgePortNumberOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port number on the of the Port on the Port Extender,
|
|
or zero for the Upstream Port."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 6 }
|
|
|
|
ieee8021BridgePECounterDiscontinuityTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime on the most recent occasion at which
|
|
any one or more of the counters in this conceptaul row
|
|
suffered a discontinuity. The relevant counters are the
|
|
specific instances associated with this conceptual row of
|
|
any Counter32 or Counter64 object. If no such discontinuities
|
|
have occurred since the last re-initialization of the local
|
|
management subsystem, then this object contains a zero value."
|
|
::= { ieee8021BridgePEPortEntry 7 }
|
|
|
|
ieee8021BridgePEPortRxrqErrorsBridge OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PE CSP flow control overflow errors
|
|
that have occured for requests on the Bridge."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 8 }
|
|
|
|
ieee8021BridgePEPortRxrspErrorsBridge OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "octets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PE CSP flow control overflow errors
|
|
that have occured for responses on the Bridge."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 9 }
|
|
|
|
ieee8021BridgePEPortRxrqErrorsPE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "frames"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PE CSP flow control overflow errors
|
|
that have occured for requests on the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 10 }
|
|
|
|
ieee8021BridgePEPortRxrspErrorsPE OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "octets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PE CSP flow control overflow errors
|
|
that have occured for responses on the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 11 }
|
|
|
|
ieee8021BridgePEPCP OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Port Exender supports
|
|
modification of the priority code point
|
|
table (true) or not (false)."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 12 }
|
|
|
|
ieee8021BridgePEROW OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Port Extender supports
|
|
rows in the PCP table in addition to the 8P0D
|
|
row (true)or not (false)."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 13 }
|
|
|
|
ieee8021BridgePEDEI OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Port Extender supports
|
|
encoding of the Drop Eligible Indicatior (true)
|
|
or not (false)."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 14 }
|
|
|
|
ieee8021BridgePECN OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Port Extender supports
|
|
Congestion Notification (true) or not (false)."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 15 }
|
|
|
|
ieee8021BridgePEPFC OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Port Extender supports
|
|
Priority-based flow control(true) or
|
|
not (false)."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 16 }
|
|
|
|
ieee8021BridgePEExtPortEChannelsSupported OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1048575)
|
|
UNITS "E-channels"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of Extended Port
|
|
E-channels supported by the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 17 }
|
|
|
|
ieee8021BridgePERemoteRepEChannelsSupported OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..3145727)
|
|
UNITS "E-channels"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of Remote Replication
|
|
E-channels supported by the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 18 }
|
|
|
|
ieee8021BridgePETCsSupported OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8)
|
|
UNITS "traffic classes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of traffic clasees
|
|
supported by the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 19 }
|
|
|
|
ieee8021BridgePEUtVLANsSupported OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4094)
|
|
UNITS "VLANs"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of untagged VLANs
|
|
supported by the Port Extender."
|
|
REFERENCE "10.2.1"
|
|
::= { ieee8021BridgePEPortEntry 20 }
|
|
|
|
-- PE Remote Replication entry table managed object
|
|
|
|
ieee8021BridgePERemoteReplicationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePERemoteReplicationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains one row for each Remote Replication
|
|
entry in the filtering database."
|
|
REFERENCE "10.3.1"
|
|
::= { ieee8021BridgePEObjects 2 }
|
|
|
|
ieee8021BridgePERemoteReplicationEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePERemoteReplicationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Remote Replication objects."
|
|
INDEX {
|
|
ieee8021BridgePEPortComponentId,
|
|
ieee8021BridgePERREcid
|
|
}
|
|
::= { ieee8021BridgePERemoteReplicationTable 1 }
|
|
|
|
Ieee8021BridgePERemoteReplicationEntry ::= SEQUENCE {
|
|
ieee8021BridgePERREcid IEEE802BridgePEEChannelIDTC,
|
|
ieee8021BridgePERRPortMap PortList
|
|
}
|
|
|
|
ieee8021BridgePERREcid OBJECT-TYPE
|
|
SYNTAX IEEE802BridgePEEChannelIDTC
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ECID assigend to this Remote Replication
|
|
filtering entry."
|
|
REFERENCE "10.3.1"
|
|
::= { ieee8021BridgePERemoteReplicationEntry 1 }
|
|
|
|
ieee8021BridgePERRPortMap OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of ports to which a frame is to be
|
|
replicated."
|
|
REFERENCE "10.3.1"
|
|
::= { ieee8021BridgePERemoteReplicationEntry 2 }
|
|
|
|
--PE Enhanced Transmission Selection table managed object
|
|
|
|
ieee8021BridgePEETSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ieee8021BridgePEETSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table that contains per port information
|
|
related to Enhanced Transmission Selection.
|
|
A row is created in this table for any port on a
|
|
Controlling Bridge that corresponds to a Cascade
|
|
Port. These objects refer to the ETS configuration
|
|
of the attached Upstream Port"
|
|
REFERENCE "10.2.2"
|
|
::= { ieee8021BridgePEObjects 3 }
|
|
|
|
ieee8021BridgePEETSEntry OBJECT-TYPE
|
|
SYNTAX Ieee8021BridgePEETSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of per Cascade Port ETS objects."
|
|
INDEX {
|
|
ieee8021BridgePEPortComponentId,
|
|
ieee8021BridgePEPort,
|
|
ieee8021BridgePEETSTrafficClass
|
|
}
|
|
::= { ieee8021BridgePEETSTable 1 }
|
|
|
|
Ieee8021BridgePEETSEntry ::= SEQUENCE {
|
|
ieee8021BridgePEETSTrafficClass
|
|
IEEE802BridgePETrafficClassValueTC,
|
|
ieee8021BridgePEETSTrafficSelectionAlgorthm
|
|
IEEE802BridgePETrafficSelectionAlgorithmTC,
|
|
ieee8021BridgePEETSBandwidth
|
|
IEEE802BridgePETrafficClassBandwidthValue
|
|
}
|
|
|
|
ieee8021BridgePEETSTrafficClass OBJECT-TYPE
|
|
SYNTAX IEEE802BridgePETrafficClassValueTC
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the traffic class to
|
|
which this bandwidth applies"
|
|
REFERENCE
|
|
"10.2.3"
|
|
::= { ieee8021BridgePEETSEntry 1 }
|
|
|
|
ieee8021BridgePEETSTrafficSelectionAlgorthm OBJECT-TYPE
|
|
SYNTAX IEEE802BridgePETrafficSelectionAlgorithmTC
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inticates the Traffic Selection Algorthm
|
|
assigned to this traffic class"
|
|
REFERENCE
|
|
"10.2.3"
|
|
::= { ieee8021BridgePEETSEntry 2 }
|
|
|
|
ieee8021BridgePEETSBandwidth OBJECT-TYPE
|
|
SYNTAX IEEE802BridgePETrafficClassBandwidthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bandwidth assigned to this traffic class."
|
|
REFERENCE
|
|
"10.2.3"
|
|
::= { ieee8021BridgePEETSEntry 3 }
|
|
|
|
-- =============================================================
|
|
-- Conformance Information
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePEGroups OBJECT IDENTIFIER
|
|
::= { ieee8021BridgePEConformance 1 }
|
|
|
|
ieee8021BridgePECompliances OBJECT IDENTIFIER
|
|
::= { ieee8021BridgePEConformance 2 }
|
|
|
|
|
|
-- =============================================================
|
|
-- Units of conformance
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePEGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
ieee8021BridgePEPortUpstreamCSPAddress,
|
|
ieee8021BridgePEPortEcid,
|
|
ieee8021BridgePEPortNumber,
|
|
ieee8021BridgePECounterDiscontinuityTime,
|
|
ieee8021BridgePEPortRxrqErrorsBridge,
|
|
ieee8021BridgePEPortRxrspErrorsBridge,
|
|
ieee8021BridgePEPortRxrqErrorsPE,
|
|
ieee8021BridgePEPortRxrspErrorsPE,
|
|
ieee8021BridgePEPCP,
|
|
ieee8021BridgePEROW,
|
|
ieee8021BridgePEDEI,
|
|
ieee8021BridgePECN,
|
|
ieee8021BridgePEPFC,
|
|
ieee8021BridgePEExtPortEChannelsSupported,
|
|
ieee8021BridgePERemoteRepEChannelsSupported,
|
|
ieee8021BridgePETCsSupported,
|
|
ieee8021BridgePEUtVLANsSupported,
|
|
ieee8021BridgePERRPortMap,
|
|
ieee8021BridgePEETSTrafficSelectionAlgorthm,
|
|
ieee8021BridgePEETSBandwidth
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects used to represent
|
|
Port Extension management objects."
|
|
::= { ieee8021BridgePEGroups 1 }
|
|
|
|
-- =============================================================
|
|
-- compliance statements
|
|
-- =============================================================
|
|
|
|
ieee8021BridgePECompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for devices supporting PE
|
|
as defined in IEEE 802.1BR."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ieee8021BridgePEGroup }
|
|
::= { ieee8021BridgePECompliances 1 }
|
|
|
|
END |