Observium_CE/mibs/nscrtv/NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB

177 lines
4.0 KiB
Plaintext

NSCRTV-HFCEMS-OPTICALAMPLIFIER-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
oaIdent
FROM NSCRTV-ROOT;
oaVendorOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS optional
DESCRIPTION
""
::= { oaIdent 1 }
oaOutputOpticalPower OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { oaIdent 2 }
oaInputOpticalPower OBJECT-TYPE
SYNTAX INTEGER ( -128..127 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaIdent 3 }
oaPumpTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaPumpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { oaIdent 4 }
oaPumpEntry OBJECT-TYPE
SYNTAX OaPumpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { oaPumpIndex }
::= { oaPumpTable 1 }
OaPumpEntry ::= SEQUENCE
{
oaPumpIndex
INTEGER,
oaPumpBIAS
INTEGER,
oaPumpTEC
INTEGER,
oaPumpTemp
INTEGER
}
oaPumpIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaPumpEntry 1 }
oaPumpBIAS OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaPumpEntry 2 }
oaPumpTEC OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
ACCESS read-only
STATUS optional
DESCRIPTION
""
::= { oaPumpEntry 3 }
oaPumpTemp OBJECT-TYPE
SYNTAX INTEGER ( 0..32768 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaPumpEntry 4 }
oaNumberDCPowerSupply OBJECT-TYPE
SYNTAX INTEGER ( 0..16 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaIdent 5 }
oaDCPowerSupplyMode OBJECT-TYPE
SYNTAX INTEGER { loadsharing(1), switchedRedundant(2), aloneSupply(3) }
ACCESS read-only
STATUS optional
DESCRIPTION
""
::= { oaIdent 6 }
oaDCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF OaDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { oaIdent 7 }
oaDCPowerEntry OBJECT-TYPE
SYNTAX OaDCPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { oaDCPowerIndex }
::= { oaDCPowerTable 1 }
OaDCPowerEntry ::= SEQUENCE
{
oaDCPowerIndex
INTEGER,
oaDCPowerVoltage
INTEGER,
oaDCPowerCurrent
INTEGER,
oaDCPowerName
DisplayString
}
oaDCPowerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaDCPowerEntry 1 }
oaDCPowerVoltage OBJECT-TYPE
SYNTAX INTEGER ( -32768..32767 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaDCPowerEntry 2 }
oaDCPowerCurrent OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaDCPowerEntry 3 }
oaDCPowerName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { oaDCPowerEntry 4 }
END