-- MIB file for PoE Ethernet Sensors (PoE-X), created 4-May-2020 by KSL
-- REVISED
POEXMIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB
TEXTUAL-CONVENTION
FROM SNMPv2-TC;
manufacturer OBJECT IDENTIFIER ::= { enterprises 41542 }
POEX OBJECT IDENTIFIER ::= { manufacturer 3 }
-- DESCRIPTION
-- "PoE-X Sensor platform supporting the delivery of data from a varity
-- of sensor type family on an Ethernet connection through the SNMP v1
-- protocol and others."
POEXGatewaySpecificInfo OBJECT IDENTIFIER ::= { POEX 1 }
-- DESCRIPTION
-- "The POEX reports certain information specific to the particular
-- gateway device, which are reported under this hierarchy."
--
-- Gateway-specific section
--
POEXGatewayID OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number identifier of the gateway device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
::= {POEXGatewaySpecificInfo 1}
POEXGatewayFirmwareVerNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version number of the firmware of the gateway device. Note that
this can change upon a firmware update."
::= {POEXGatewaySpecificInfo 2}
POEXGatewaySensorDeviceCount OBJECT-TYPE
SYNTAX INTEGER(0..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of sensors registered to the gateway, i.e. on its netlist.
Note that this can change as sensors are added or removed."
::= {POEXGatewaySpecificInfo 3}
POEXGatewayTrapIPAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The configured destination IP address for trap messages from this
gateway."
::= {POEXGatewaySpecificInfo 4}
POEXGatewaySensorTrapPort OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The configured IP port for trap messages from this gateway."
::= {POEXGatewaySpecificInfo 5}
--
-- Definitions of sensor-specific informational types
--
POEXSensorID ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
SYNTAX Unsigned32
POEXSensorRegistrationIndex ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The index number of a sensor device in a gateway's sensor
registration list. This is determined by the order in which a set
of sensors has been registered, but will not change so long as
the list remains fixed. This is included for legacy applications:
please consider using the more convenient
POEXSensorInfoTranslatedFormat and
POEXSensorInfoBySensorID hierarchies."
SYNTAX INTEGER(0..255)
POEXDatumNo ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The datum number of a sequence of data readings from a sensor. The
range of this type depends upon the number of datums reported by
a sensor device. Thus, a 3-axis accelerometer sensor might report
three datums for the X, Y and Z axes, and the datums would range
from 1 to 3. For a simple temperature sensor reporting one
reading, this value would always be 1."
SYNTAX INTEGER(1..8)
POEXSensorDeviceType ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The textual description of the type of the sensor device."
SYNTAX OCTET STRING
POEXDatumNumber ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The number of a datum in a set of datums comprising a sensor reading.
For sensors reporting one datum, this will always be one. Otherwise
it will be a number between 1 and the number of datums reported by
the particular type of sensor."
SYNTAX INTEGER
POEXSensorDeviceReadingTranslatedValue ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The value of a sensor reading, in textual format, translated
according to sensor and datum types. These formats can include
integers, fixed-point, and binary values. In several examples:
a pulse counter might report '12345', a current sensor might report
'1.43', and a door closed sensor might report 'Yes'."
SYNTAX OCTET STRING
POEXSensorDeviceReadingTranslatedUnits ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The units or scale of value of a sensor reading, reported in textual
format. In several examples: a pulse counter might report 'Count',
a current sensor might report 'A', and a door sensor might report
'Closed'."
SYNTAX OCTET STRING
POEXSensorDeviceReadingValuesAll ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"All of the datums for the most recent reading of the sensor device,
separated by commas, in textual format. For example, a report for a
temperature and humidity sensor might read '20.3, 35' indicating
20.3 degrees at 35 percent humidity. If only one datum is reported
by a sensor device, e.g. for a simple temperature sensor, it will be
reported singly with no commas."
SYNTAX OCTET STRING
POEXSensorDeviceReadingUnitsAll ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"All of the units corresponding to the datums for the most recent
reading of the sensor device, separated by commas, in textual
format. For example, for a sensor reporting temperature and
humidity this might read 'degrees C, %RH'"
SYNTAX OCTET STRING
POEXSensorDeviceReadingUntranslated ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The untranslated data block received from a sensor, in hexadecimal
format. This may be used where a translating function isn't yet
present, and for development purposes. Most users should use the
translated values delivered in the format of
POEXSensorDeviceReadingValuesAll."
SYNTAX OCTET STRING
POEXSensorDeviceReadingU32Value ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"Either a single sensor value of up to 32 bits, or half of a
64-bit value. Thus where a sensor value is reportable in a
single Unsigned32, one OID is sufficient to gather that value.
Where more than 32 bits are needed, the value is reported in two
successive values of type POEXSensorDeviceReadingU32Value.
Where a set of datums is reported, those datums are reported
beginning with the lowest-numbered OID proceeding sequentially
through the highest. Thus were a sensor to report a single-bit
value A followed by 32-bit and a 64 bit ones B and C, and where
OIDS x.10 through x.17 were used for reporting values, the value A
would be encoded in x.10, B in x.11 and C in x.12 (low-order bits)
and x.13 (high-order bits). These values are merely converted
from sensor-specific internal formats to integers, and not beyond
to human-readable formats.
Furthermore, where for a sensor datums extend only part-way through
the available U32Value OIDs, the ones unused may be filled with 0.
Where an SNMP walk is performed, the gateway may not traverse these
unused OIDs."
SYNTAX Unsigned32
POEXSensorDeviceReadingAge ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The age of the sensor report received most recently from a sensor.
That time is reported as the number of seconds between the time of
the sensor report and the time this information is requested."
SYNTAX Unsigned32
POEXSensorDeviceReadingAlarming ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"Either 'Alarming' or 'Not alarming'. A device will report an alarm
if it is programmed with a threshold found to be exceeded. Examples:
a temperature sensor for a refrigeration unit can be programmed to
alarm if the measured temperature rises above a threshold, and
a door sensor might alarm if a security door is opened."
SYNTAX OCTET STRING
--
-- Sensor-specific section, translated format
--
POEXSensorInfoTranslatedFormatTable OBJECT-TYPE
SYNTAX SEQUENCE OF POEXSensorInfoTranslatedFormatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table containing sensor-specific information in an
easy-to-use translated string format, indexed by sensor ID is reported
under this hierarchy. Sensor data is translated by the gateway from
sensor-internal format to human-readable and scriptable values. Use of
this format is preferred for most users. The gateway will report the
most current information received from sensors, according to their
programmed reporting period or heartbeat. When using this section
through getRequests or getNextRequests, successive polling is required
to keep sensor data current. This table can change as sensors are
added or removed. If queried, this OID will return the number of rows
in the table, which is the number of sensors registered to this gateway."
::= { POEX 2 }
-- Table portion consisting of non-datum-specific info
POEXSensorInfoTranslatedFormatEntry OBJECT-TYPE
SYNTAX POEXSensorInfoTranslatedFormatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the Translated Format Table containing
the latest sensor state for a single sensor."
INDEX { POEXSensorInfoTranslatedFormatSensorDeviceID }
::= { POEXSensorInfoTranslatedFormatTable 1 }
POEXSensorInfoTranslatedFormatEntry ::= SEQUENCE {
POEXSensorInfoTranslatedFormatSensorDeviceID POEXSensorID,
POEXSensorInfoTranslatedFormatSensorDeviceType POEXSensorDeviceType,
POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll POEXSensorDeviceReadingValuesAll,
POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll POEXSensorDeviceReadingUnitsAll,
POEXSensorInfoTranslatedFormatSensorDeviceRptUT POEXSensorDeviceReadingUntranslated,
POEXSensorInfoTranslatedFormatSensorDeviceReadingTime DisplayString,
POEXSensorInfoTranslatedFormatSensorDeviceReadingAge POEXSensorDeviceReadingAge,
POEXSensorInfoTranslatedFormatSensorDeviceTypeNo DisplayString,
POEXSensorInfoTranslatedFormatSensorDeviceRFStrength DisplayString,
POEXSensorInfoTranslatedFormatSensorDeviceActive DisplayString,
POEXSensorInfoTranslatedFormatSensorDeviceAlarming POEXSensorDeviceReadingAlarming,
POEXSensorInfoTranslatedFormatSensorDeviceVoltage DisplayString,
POEXSensorInfoTranslatedFormatSensorDeviceWDIndexNo DisplayString
}
POEXSensorInfoTranslatedFormatSensorDeviceID OBJECT-TYPE
SYNTAX POEXSensorID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
::= { POEXSensorInfoTranslatedFormatEntry 1 }
POEXSensorInfoTranslatedFormatSensorDeviceType OBJECT-TYPE
SYNTAX POEXSensorDeviceType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The textual description of the type of the sensor device."
::= {POEXSensorInfoTranslatedFormatEntry 2 }
POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingValuesAll
ACCESS read-only
STATUS mandatory
DESCRIPTION
"All of the datums for the most recent reading of the sensor device,
separated by commas, in textual format. For example, a report for a
temperature and humidity sensor might read '20.3, 35' indicating
20.3 degrees at 35 percent humidity. If only one datum is reported
by a sensor device, e.g. for a simple temperature sensor, it will be
reported singly with no commas. The use of this OID is recommended
for most users, rather than the single value ones, because all values
can be retrieved atomically from a sensor in one SNMP request."
::= {POEXSensorInfoTranslatedFormatEntry 3 }
POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingUnitsAll
ACCESS read-only
STATUS mandatory
DESCRIPTION
"All of the units corresponding to the datums for the most recent
reading of the sensor device, separated by commas, in textual
format. For example, for a sensor reporting temperature and
humidity this might read 'degrees C, %RH'"
::= {POEXSensorInfoTranslatedFormatEntry 4 }
POEXSensorInfoTranslatedFormatSensorDeviceRptUT OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingUntranslated
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The untranslated data block received from a sensor, in hexadecimal
format. This may be used where a translating function isn't yet
present, and for development purposes. Most users should use the
translated values delivered in the format of
POEXSensorDeviceReadingValuesAll."
::= {POEXSensorInfoTranslatedFormatEntry 5 }
POEXSensorInfoTranslatedFormatSensorDeviceReadingTime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time of the sensor report received most recently from a sensor.
That time is reported as the number of seconds elapsed since the epoch
of the gateway, which is presently Jan. 1, 2010."
::= {POEXSensorInfoTranslatedFormatEntry 6 }
POEXSensorInfoTranslatedFormatSensorDeviceReadingAge OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingAge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The age of the sensor report received most recently from a sensor.
That time is reported as the number of seconds between the time of
the sensor report and the time this information is requested."
::= {POEXSensorInfoTranslatedFormatEntry 7 }
POEXSensorInfoTranslatedFormatSensorDeviceTypeNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The manufacturer's type number that identifies the kind of sensor."
::= {POEXSensorInfoTranslatedFormatEntry 8 }
POEXSensorInfoTranslatedFormatSensorDeviceRFStrength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The signal strength, in percent, of the radio link between the gateway
and the particular sensor, as measured at the time of the most recent
sensor report."
::= {POEXSensorInfoTranslatedFormatEntry 9 }
POEXSensorInfoTranslatedFormatSensorDeviceActive OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 'Active' or '' (an empty string). A sensor will be reported
active if it has recently communicated with the gateway since the last
reboot. If a sensor device does not show active, it is likely because
(1) the sensor lacks a power source, (2) the sensor is not in
proximity to the gateway, or (3) the gateway has recently been
powered on, and the sensor hasn't yet communicated."
::= {POEXSensorInfoTranslatedFormatEntry 10 }
POEXSensorInfoTranslatedFormatSensorDeviceAlarming OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingAlarming
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 'Alarming' or 'Not alarming'. A device will report an alarm
if it is programmed with a threshold found to be exceeded. Examples:
a temperature sensor for a refrigeration unit can be programmed to
alarm if the measured temperature rises above a threshold, and
a door sensor might alarm if a security door is opened."
::= {POEXSensorInfoTranslatedFormatEntry 11 }
POEXSensorInfoTranslatedFormatSensorDeviceVoltage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the voltage of the supply powering a sensor device.
Ordinarily this will report the voltage at the battery terminals of
a sensor. It is provided mainly so batteries can be changed when
depleted."
::= {POEXSensorInfoTranslatedFormatEntry 12 }
POEXSensorInfoTranslatedFormatSensorDeviceWDIndexNo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the sensor in the gateway's sensor registration
table. This is the number used in referencing the sensor in the
POEXSensorInformationBySensorRegisOrder
hierarchy."
::= {POEXSensorInfoTranslatedFormatEntry 13 }
-- Table portion consisting of datum-specific info (single values and units addressed by device ID and datum)
POEXSensorInfoTranslatedFormatByDatumNumberEntry OBJECT-TYPE
SYNTAX POEXSensorInfoTranslatedFormatByDatumNumberEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the Translated Format Table containing
the sensor datums, indexed by a sensor ID and datum number."
INDEX { POEXSensorInfoTranslatedFormatSensorDeviceID,
POEXSensorInfoTranslatedFormatByDatumNumberDatumNumber }
::= { POEXSensorInfoTranslatedFormatTable 2 }
POEXSensorInfoTranslatedFormatByDatumNumberEntry ::= SEQUENCE {
POEXSensorInfoTranslatedFormatByDatumNumberSensorDeviceID POEXSensorID,
POEXSensorInfoTranslatedFormatByDatumNumberDatumNumber POEXDatumNumber,
POEXSensorInfoTranslatedFormatByDatumNumberReadingValue POEXSensorDeviceReadingTranslatedValue,
POEXSensorInfoTranslatedFormatByDatumNumberReadingUnits POEXSensorDeviceReadingTranslatedUnits
}
POEXSensorInfoTranslatedFormatByDatumNumberSensorDeviceID OBJECT-TYPE
SYNTAX POEXSensorID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
::= { POEXSensorInfoTranslatedFormatByDatumNumberEntry 1 }
POEXSensorInfoTranslatedFormatByDatumNumberDatumNumber OBJECT-TYPE
SYNTAX POEXDatumNumber
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of a datum in a set of datums comprising a sensor reading.
For sensors reporting one datum, this will always be one. Otherwise
it will be a number between 1 and the number of datums reported by
the particular type of sensor."
::= { POEXSensorInfoTranslatedFormatByDatumNumberEntry 2 }
POEXSensorInfoTranslatedFormatByDatumNumberReadingValue OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingTranslatedValue
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a sensor reading, in textual format, translated
according to sensor and datum types. These formats can include
integers, fixed-point, and binary values. In several examples:
a pulse counter might report '12345', a current sensor might report
'1.43', and a door sensor might report 'closed'."
::= { POEXSensorInfoTranslatedFormatByDatumNumberEntry 3 }
POEXSensorInfoTranslatedFormatByDatumNumberReadingUnits OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingTranslatedUnits
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The units or scale of value of a sensor reading, reported in textual
format. In several examples: a pulse counter might report 'Count',
a current sensor might report 'A', and a door sensor might report
'Closed'."
::= { POEXSensorInfoTranslatedFormatByDatumNumberEntry 4 }
--
-- Sensor-specific section, untranslated legacy format, by sensor ID
--
POEXSensorInfoBySensorIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF POEXSensorInfoBySensorIDSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table containing sensor information in a legacy
untranslated numeric format, addressed by sensor ID. This is provided
for users who need a precise match of the format of the older EGW1
platform. The gateway will report the most current information received
from sensors, according to their programmed reporting period or
heartbeat. A more convenient format to new users is available under
the POEXSensorInfoTranslatedFormat. If queried, this
OID will return the number of rows in the table, which is the number
of sensors registered to this gateway."
::= { POEX 3 }
POEXSensorInfoBySensorIDEntry OBJECT-TYPE
SYNTAX POEXSensorInfoBySensorIDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the untranslated by-sensor-ID-order
table containing the latest sensor state for a single sensor."
INDEX { POEXSensorInfoBySensorIDSensorDeviceID }
::= { POEXSensorInfoBySensorIDTable 1 }
POEXSensorInfoBySensorIDEntry ::= SEQUENCE {
POEXSensorInfoBySensorIDSensorDeviceID Unsigned32,
POEXSensorInfoBySensorIDSensorDeviceWDIndexNo INTEGER,
POEXSensorInfoBySensorIDSensorDeviceTypeNo INTEGER,
POEXSensorInfoBySensorIDSensorDeviceReadingAge Unsigned32,
POEXSensorInfoBySensorIDSensorDeviceActive INTEGER,
POEXSensorInfoBySensorIDSensorDeviceAlarming INTEGER,
POEXSensorInfoBySensorIDSensorDeviceVoltage INTEGER,
POEXSensorInfoBySensorIDSensorDeviceRFStrength INTEGER,
POEXSensorInfoBySensorIDSensorDeviceRptUT DisplayString,
POEXSensorInfoBySensorIDSensorDeviceReadingValue1 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue2 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue3 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue4 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue5 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue6 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue7 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorIDSensorDeviceReadingValue8 POEXSensorDeviceReadingU32Value
}
POEXSensorInfoBySensorIDSensorDeviceID OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 1 }
POEXSensorInfoBySensorIDSensorDeviceWDIndexNo OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the sensor in the gateway's sensor registration
table. This is the number used in referencing the sensor in the
POEXSensorInfoBySensorRegisOrder
hierarchy."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 2 }
POEXSensorInfoBySensorIDSensorDeviceTypeNo OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The manufacturer's type number that identifies the kind of sensor."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 3 }
POEXSensorInfoBySensorIDSensorDeviceReadingAge OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The age of the sensor report received most recently from a sensor.
That time is reported as the number of seconds between the time of
the sensor report and the time this information is requested."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 4 }
POEXSensorInfoBySensorIDSensorDeviceActive OBJECT-TYPE
SYNTAX INTEGER(0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 1 (active) or 0 (inactive). A sensor will be reported active
if it has recently communicated with the gateway since the last
reboot. If a sensor device does not show active, it is likely because
(1) the sensor lacks a power source, (2) the sensor is not in
proximity to the gateway, or (3) the gateway has recently been
powered on, and the sensor hasn't yet communicated."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 5 }
POEXSensorInfoBySensorIDSensorDeviceAlarming OBJECT-TYPE
SYNTAX INTEGER(0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 1 (alarming) or 0 (not alarming)'. A device will report an
alarm if it is programmed with a threshold found to be exceeded.
Examples: a temperature sensor for a refrigeration unit can be
programmed to alarm if the measured temperature rises above a
threshold, and a door sensor might alarm if a security door is opened."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 6 }
POEXSensorInfoBySensorIDSensorDeviceVoltage OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value representing the voltage of the supply powering a sensor
device. Ordinarily this will report the voltage at the battery
terminals of a sensor. It is provided mainly so batteries can be
changed when depleted. The formula for calculating the voltage from
this number is: voltage=(150 + v) / 10.0."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 7 }
POEXSensorInfoBySensorIDSensorDeviceRFStrength OBJECT-TYPE
SYNTAX INTEGER(-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The signal strength, in percent, of the radio link between the gateway
and the particular sensor, as measured at the time of the most recent
sensor report."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 8 }
POEXSensorInfoBySensorIDSensorDeviceRptUT OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The untranslated data block received from a sensor, in hexadecimal
format. This may be used where a translating function isn't yet
present, and for development purposes. Most users should use the
translated values delivered in the format of
POEXSensorDeviceReadingValuesAll."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 9 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue1 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 10 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue2 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 11 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue3 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 12 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue4 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 13 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue5 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 14 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue6 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 15 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue7 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 16 }
POEXSensorInfoBySensorIDSensorDeviceReadingValue8 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
INDEX { POEXSensorID }
::= {POEXSensorInfoBySensorIDEntry 17 }
--
-- Sensor-specific section, untranslated legacy format, by registration order
--
POEXSensorInfoBySensorRegisOrderTable OBJECT-TYPE
SYNTAX SEQUENCE OF POEXSensorInfoBySensorRegisOrderSensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The (conceptual) table containing an untranslated numeric format,
addressed by sensor registration order starting at 1 and ascending by
one, in a legacy integer format. This is provided for users who need a
precise match of the format and order of the older EGW1 platform.
The gateway will report the most current information received from
sensors, according to their programmed reporting period or heartbeat.
A more convenient format to new users is available under
the POEXSensorInfoTranslatedFormat. If queried, this
OID will return the number of rows in the table, which is the number
of sensors registered to this gateway."
::= { POEX 4 }
POEXSensorInfoBySensorRegisOrderEntry OBJECT-TYPE
SYNTAX POEXSensorInfoBySensorRegisOrderEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry (conceptual row) in the untranslated by-registration-order
table containing the latest sensor state for a single sensor."
INDEX { POEXSensorInfoBySensorRegisOrderSensDevID }
::= { POEXSensorInfoBySensorRegisOrderTable 1 }
POEXSensorInfoBySensorRegisOrderEntry ::= SEQUENCE {
POEXSensorInfoBySensorRegisOrderSensorDeviceID Unsigned32,
POEXSensorInfoBySensorRegisOrderSensorDeviceWDIndexNo INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceTypeNo INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingAge Unsigned32,
POEXSensorInfoBySensorRegisOrderSensorDeviceActive INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceAlarming INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceVoltage INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceRFStrength INTEGER,
POEXSensorInfoBySensorRegisOrderSensorDeviceRptUT DisplayString,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue1 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue2 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue3 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue4 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue5 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue6 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue7 POEXSensorDeviceReadingU32Value,
POEXSensorInfoBySensorRegisOrderSensorDeviceReadingValue8 POEXSensorDeviceReadingU32Value
}
POEXSensorInfoBySensorRegisOrderSensDevID OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 1 }
POEXSensorInfoBySensorRegisOrderSensDevWDIndexNo OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the sensor in the gateway's sensor registration
table. This is the number used in referencing the sensor in the
POEXSensorInfoBySensorRegisOrder hierarchy."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 2 }
POEXSensorInfoBySensorRegisOrderSensDevTypeNo OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The manufacturer's type number that identifies the kind of sensor."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 3 }
POEXSensorInfoBySensorRegisOrderSensDevReadingAge OBJECT-TYPE
SYNTAX Unsigned32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The age of the sensor report received most recently from a sensor.
That time is reported as the number of seconds between the time of
the sensor report and the time this information is requested."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 4 }
POEXSensorInfoBySensorRegisOrderSensDevActive OBJECT-TYPE
SYNTAX INTEGER(0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 1 (active) or 0 (inactive). A sensor will be reported active
if it has recently communicated with the gateway since the last
reboot. If a sensor device does not show active, it is likely because
(1) the sensor lacks a power source, (2) the sensor is not in
proximity to the gateway, or (3) the gateway has recently been
powered on, and the sensor hasn't yet communicated."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 5 }
POEXSensorInfoBySensorRegisOrderSensDevAlarming OBJECT-TYPE
SYNTAX INTEGER(0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Either 1 (alarming) or 0 (not alarming)'. A device will report an
alarm if it is programmed with a threshold found to be exceeded.
Examples: a temperature sensor for a refrigeration unit can be
programmed to alarm if the measured temperature rises above a
threshold, and a door sensor might alarm if a security door is opened."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 6 }
POEXSensorInfoBySensorRegisOrderSensDevVoltage OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value representing the voltage of the supply powering a sensor
device. Ordinarily this will report the voltage at the battery
terminals of a sensor. It is provided mainly so batteries can be
changed when depleted. The formula for calculating the voltage from
this number is: voltage=(150 + v) / 10.0."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 7 }
POEXSensorInfoBySensorRegisOrderSensDevRFStrength OBJECT-TYPE
SYNTAX INTEGER(-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The signal strength, in percent, of the radio link between the gateway
and the particular sensor, as measured at the time of the most recent
sensor report."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 8 }
POEXSensorInfoBySensorRegisOrderSensDevRptUT OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The untranslated data block received from a sensor, in hexadecimal
format. This may be used where a translating function isn't yet
present, and for development purposes. Most users should use the
translated values delivered in the format of
POEXSensorDeviceReadingValuesAll."
INDEX { POEXSensorRegistrationIndex }
::= {POEXSensorInfoBySensorRegisOrderEntry 9 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl1 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 10 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl2 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 11 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl3 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 12 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl4 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 13 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl5 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 14 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl6 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 15 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl7 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 16 }
POEXSensorInfoBySensorRegisOrderSensDevReadingVl8 OBJECT-TYPE
SYNTAX POEXSensorDeviceReadingU32Value
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of a single sensor reading, or one half of a 64-bit reading,
in integer format, not translated to human-readable form. See
POEXSensorDeviceReadingU32Value for further explanation."
::= {POEXSensorInfoBySensorRegisOrderEntry 17 }
--
-- Traps
--
--Map of types used in traps to those used in requests
-- POEX-Trap-DevIDReported ::= POEX-GatewayID
-- POEX-Trap-AllValuesReported ::=
-- CHOICE {
-- POEX-trap-values-translatable POEX-SensorDeviceReadingValuesAll,
-- POEX-trap-values-unknown POEX-SensorDeviceReadingUntranslated
-- }
-- POEX-Trap-AllUnitsReported ::= POEX-SensorDeviceReadingUnitsAll
-- POEX-Trap-AgeReported ::= POEX-SensorDeviceReadingUnitsAll
-- POEX-Trap-AlarmingReported ::= POEX-SensorDeviceReadingUnitsAll
POEXTrapDevIDReported ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The serial number identifier of the sensor device assigned and
programmed by the manufacturer. This will ordinarily be printed
on a label on the housing of the device. POEXTrapDevIDReported
is the same as POEXSensorID."
SYNTAX Unsigned32(1..2147483631)
POEXTrapAllValuesReported ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"This will make one of two reports. For the case the sensor type is
known to the gateway, this will be all of the datums for the most
recent reading of the sensor device, separated by commas, in textual
format, using the POEXSensorDeviceReadingValuesAll format.
Where the sensor type is not known to the gateway, this will be
the untranslated data block received from a sensor, in hexadecimal
format. This POEXTrapAllValuesReported is the same as either
POEXSensorDeviceReadingValuesAll or
POEXSensorDeviceReadingUntranslated."
SYNTAX OCTET STRING
POEXTrapAllUnitsReported ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"All of the units corresponding to the datums for the most recent
reading of the sensor device, separated by commas, in textual
format. For example, for a sensor reporting temperature and
humidity this might read 'degrees C, %RH'.
POEXTrapAllUnitsReported is the same as
POEXSensorDeviceReadingUnitsAll."
SYNTAX OCTET STRING
POEXTrapAgeReported ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"The age of the sensor report received most recently from a sensor.
That time is reported as the number of seconds between the time of
the sensor report and the time this information is requested.
POEXTrapAgeReported is the same as
POEXSensorDeviceReadingAge."
SYNTAX OCTET STRING
POEXTrapAlarmingReported ::= TEXTUAL-CONVENTION
STATUS mandatory
DESCRIPTION
"Either 'Alarming' or 'Not alarming'. A device will report an alarm
if it is programmed with a threshold found to be exceeded. Examples:
a temperature sensor for a refrigeration unit can be programmed to
alarm if the measured temperature rises above a threshold, and
a door sensor might alarm if a security door is opened.
POEXTrapAlarmingReported is the same as
POEXSensorDeviceReadingAlarming."
SYNTAX OCTET STRING
POEXNewSensorTraffic TRAP-TYPE
ENTERPRISE POEX
VARIABLES {
POEXSensorInfoTranslatedFormatSensorDeviceID, POEXTrapDevIDReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll, POEXTrapAllValuesReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll, POEXTrapAllUnitsReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingAge, POEXTrapAgeReported,
POEXSensorInfoTranslatedFormatSensorDeviceAlarming, POEXTrapAlarmingReported
}
DESCRIPTION
"This trap, when enabled, will generate a report corresponding to new
data from any registered sensor as it is received. Included with the
trap message are the sensor ID, all values the sensor reports, units for
all those values, the age, and whether the sensor is alarming."
::= 1
POEXDeviceAlarming TRAP-TYPE
ENTERPRISE POEX
VARIABLES {
POEXSensorInfoTranslatedFormatSensorDeviceID, POEXTrapDevIDReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingValuesAll, POEXTrapAllValuesReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingUnitsAll, POEXTrapAllUnitsReported,
POEXSensorInfoTranslatedFormatSensorDeviceReadingAge, POEXTrapAgeReported,
POEXSensorInfoTranslatedFormatSensorDeviceAlarming, POEXTrapAlarmingReported
}
DESCRIPTION
"This trap, when enabled, will generate a report corresponding to new
data from any registered sensor as it is received, but only if that
sensor is alarming and the POEXNewSensorTraffic trap is disabled.
(That trap will generate the same message, rendering this trap redundant.)
Included with the trap message are the sensor ID, all values the sensor
reports, units for all those values, the age, and whether the sensor
is alarming."
::= 2
END