-- CISCO-LPTS-MIB.my
-- Local Packet Transport Service(LPTS) MIB file
-- March 2013, <Harish Gumaste>
-- Copyright (c) 2013 by cisco Systems Inc.
-- All rights reserved.
--
-- *****************************************************************
CISCO-LPTS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter64,
Unsigned32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION
FROM SNMPv2-TC
ciscoMgmt
FROM CISCO-SMI
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB;
ciscoLptsMIB MODULE-IDENTITY
LAST-UPDATED "201309030000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
"Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-q-lpts-dev@cisco.com"
DESCRIPTION
"The MIB module for Local Packet Transport Services(LPTS)
related information like the flows and the policer
values related to various flows present in the system.
The number of packets coming into the system is controlled
by the policer values associated with the protocol. Each
protocol is classified into different flows and a rate
limit is associated with the flows. Policer is a numerical
value controlling the number of packets entering the box.
The flows represent individual, specific protocols.
Flow types also represent the degree of trust for a given
packet. Ex: BGP packets coming from established session is
assigned one flow, packets from configured BGP peer are
assigned different flow . Other BGP packets are assigned
a third flow.
Definitions:
LPTS - Local Packet Transport Services.
It is a network infrastructure
subsystem that provides a common
facility for transport of packets
which are destined towards the router
(for-us packets), to the exact
applications. In addtion
to that, it also
provides policing of for-us packets
FlowType - Represents individual, specific protocols.
Flow also represents the degree of trust
for a given packet.
LC - Line Cards.
Policer - Index to FlowType.
CurrentRate - Number of packets allowed
into the box in PPS (Packets Per Second).
Type - Defines the scope of the flow applicable at
a specific node or Line card.
Precedence - Precedence is the selection mechanism for
a specific Type if more than one Type is
configured for the same flow. 'local'
FlowType has higher precedence over 'global'
and 'static' FlowTypes. 'global' FlowType has
higher precedence over 'static' FlowType.
nodeID - The line card for which the flow configuration
is made."
REVISION "201309030000Z"
DESCRIPTION
"Latest version of this MIB module."
::= { ciscoMgmt 812 }
ClFlowType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An enumeration unsigned integer which indicates the scope of
flow applicable at a specific node or Line Card (LC).
Precedence is the selection mechanism for a specific Type
if more than one Type is configured for the same flow.
When Type 'local' and 'global' are configured for the
same flow, then 'local' Type takes precedence. If
'local' Type is not configured, then 'global' Type would
be applied if it is present. If neither the 'local' nor
the 'global' Type is configured, then the ClFlowType is
derived from the static configuration file which is of
Type 'static'."
SYNTAX INTEGER {
static(1), -- the flow derived from a
-- static config file.
-- When ClFlowType is "Static", implies
-- neither local nor
-- global configuration is present.
global(2), -- ClFlowType is "Global" when
-- flow is
-- configured across all the
--Linecards.
local(3) -- ClFlowType is "Local" when
-- flow is
-- configured specific to Linecard.
}
-- Textual Conventions definition will be defined before this line
ciscoLptsMIBNotifs OBJECT IDENTIFIER
::= { ciscoLptsMIB 0 }
ciscoLptsMIBObjects OBJECT IDENTIFIER
::= { ciscoLptsMIB 1 }
ciscoLptsMIBConform OBJECT IDENTIFIER
::= { ciscoLptsMIB 2 }
clGlobalFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClGlobalFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table respresents the flows configured globally and
the configuration will be reflected across all the linecards"
::= { ciscoLptsMIBObjects 1 }
clGlobalFlowEntry OBJECT-TYPE
SYNTAX ClGlobalFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry will be added into clGlobalFlowTable
when LPTS flows configured without any
location specific details. Similarly when the global
LPTS flow config is removed, then type and rate
retained as per Static config file. The entries in this
table can be of Type either 'global' or 'static'."
INDEX { clGlobalFlowIndex }
::= { clGlobalFlowTable 1 }
ClGlobalFlowEntry ::= SEQUENCE {
clGlobalFlowIndex Unsigned32,
clGlobalFlowType SnmpAdminString,
clGlobalType ClFlowType,
clGlobalCurrentRate Unsigned32
}
clGlobalFlowIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An unique value used to represent a
row in the clGlobalFlowTable"
::= { clGlobalFlowEntry 1 }
clGlobalFlowType OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the flow type name
associated with every flow.
Eg. FlowType could be BGP-Known, BGP-configured
BGP-default."
::= { clGlobalFlowEntry 2 }
clGlobalType OBJECT-TYPE
SYNTAX ClFlowType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an enumeration
which indicates whether LPTS flow
configured across all the linecards are 'global' or
'static' depending on the predecedence"
::= { clGlobalFlowEntry 3 }
clGlobalCurrentRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "PPS"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the rate associated
with the flow type which is configured
globally."
::= { clGlobalFlowEntry 4 }
-- There is not relationship between global flow table and local flow
-- table. All the configurations made based on a location are present in
-- the local flow table and any configurations made without any location
-- specific details are present in the global flow table.
clLocalFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF ClLocalFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table represents the configurations for the local
flow types & affects a
particular nodeID for which config is applied.
When local flow type is not configured & we have a global
configuration then the clLocalFlowTable has global flow value.
If neither local flow nor the global flows are
configured, then clLocalFlowTable will have static
values derived from the config file. If both the local
flow and global flow is configured, then the local flow
information takes precedence over the global flow
information."
::= { ciscoLptsMIBObjects 2 }
clLocalFlowEntry OBJECT-TYPE
SYNTAX ClLocalFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in clLocalFlowTable will be added when LPTS flows
are configured specific to a location. This table is indexed
based on nodeID and clGlobalFlowIndex. When NMS polls for flow
in clLocalFlowTable, the flow name is retrieved from the
clGlobalFlowTable. When a local configuration is removed for
a flow, then clGlobalCurrentRate will be applied if it
is present, else static rate will be applied."
INDEX {
clGlobalFlowIndex,
clLocalNodeID
}
::= { clLocalFlowTable 1 }
ClLocalFlowEntry ::= SEQUENCE {
clLocalNodeID Unsigned32,
clLocalType ClFlowType,
clLocalCurrentRate Unsigned32,
clLocalAccepted Counter64,
clLocalDropped Counter64,
clLocalTosValue Unsigned32
}
clLocalNodeID OBJECT-TYPE
SYNTAX Unsigned32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The linecard for which the flow configuration is made."
::= { clLocalFlowEntry 1 }
clLocalType OBJECT-TYPE
SYNTAX ClFlowType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an enumeration
which indicates LPTS flows
configured specific to a linecard"
::= { clLocalFlowEntry 2 }
clLocalCurrentRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "PPS"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the packet rate associated
with the flow type with which packets
are accepted or dropped specific to a linecard."
::= { clLocalFlowEntry 3 }
-- localFlowStats is used to find the statistics associated with that
-- flow. We want to keep track of both the accept count as well as drop
-- count. Hence we have used two objects as localFlowTotalAcceptCount
-- and localFlowTotalDropCount
clLocalAccepted OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of packets accepted
on a linecard for a specific flow."
::= { clLocalFlowEntry 4 }
clLocalDropped OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the total number of packets dropped on
a linecard for a specific flow."
::= { clLocalFlowEntry 5 }
clLocalTosValue OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the type of service."
::= { clLocalFlowEntry 6 }
ciscoLptsMIBCompliances OBJECT IDENTIFIER
::= { ciscoLptsMIBConform 1 }
ciscoLptsMIBGroups OBJECT IDENTIFIER
::= { ciscoLptsMIBConform 2 }
ciscoLptsMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which
implement the Cisco LPTS MIB."
MODULE -- this module
MANDATORY-GROUPS {
clLocalFlowGroup,
clGlobalFlowGroup
}
::= { ciscoLptsMIBCompliances 1 }
-- Units of Conformance
clGlobalFlowGroup OBJECT-GROUP
OBJECTS {
clGlobalFlowType,
clGlobalCurrentRate,
clGlobalType
}
STATUS current
DESCRIPTION
"A collection of objects which provides information
about flow type and current rate configured across all
Linecards."
::= { ciscoLptsMIBGroups 1 }
clLocalFlowGroup OBJECT-GROUP
OBJECTS {
clLocalCurrentRate,
clLocalAccepted,
clLocalDropped,
clLocalType,
clLocalTosValue
}
STATUS current
DESCRIPTION
"A collection of objects which provides information
about current rate and accept/drop statistics for a specific
linecard."
::= { ciscoLptsMIBGroups 2 }
END