-- ***************************************************************** -- EKINOPS-Pm1001lhr.TXT: MIB -- --MIB Part Number:3MI00011AIAD --MIB Version:02 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pm1001lhr-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePm1001lhr MODULE-IDENTITY LAST-UPDATED "201606020000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "MIB for managing Ekinops modules with PM1001LHR software" REVISION "200702010000Z" DESCRIPTION "Initial Version." REVISION "200705310000Z" DESCRIPTION "Using EkiProtocol instead of EkiLineProtocol." REVISION "200706290000Z" DESCRIPTION "Add DCC alarms." REVISION "200712050000Z" DESCRIPTION "Update Ekinops address,Helps on objects, Ports Labels" REVISION "200811270000Z" DESCRIPTION "DCC storm info suppress" REVISION "200902060000Z" DESCRIPTION "Add OTX-TLH features" REVISION "200910070000Z" DESCRIPTION "Add Condtype parameters" REVISION "201002150000Z" DESCRIPTION "Probcause,AlarmType - NMS" REVISION "201102030000Z" DESCRIPTION "Formulas in comments and Event on XFP init" REVISION "201207030000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403280000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201501200000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605200000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" REVISION "201606020000Z" DESCRIPTION "Capabilities objects of Table 5" ::= { ekinops 22 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pm1001lhralarms OBJECT IDENTIFIER ::= { modulePm1001lhr 2 } pm1001lhrAlmOther OBJECT IDENTIFIER ::= { pm1001lhralarms 1 } pm1001lhrAlmOtherNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 1 } pm1001lhrAlmOtherUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 2 } pm1001lhrAlmOtherCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmOther 3 } pm1001lhrAlmClient OBJECT IDENTIFIER ::= { pm1001lhralarms 2 } pm1001lhrAlmClientNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 1 } pm1001lhrAlmClientUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 2 } pm1001lhrAlmClientCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmClient 3 } pm1001lhrAlmLine OBJECT IDENTIFIER ::= { pm1001lhralarms 3 } pm1001lhrAlmLineNurg OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 1 } pm1001lhrAlmLineUrg OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 2 } pm1001lhrAlmLineCrit OBJECT IDENTIFIER ::= { pm1001lhrAlmLine 3 } pm1001lhrmeasures OBJECT IDENTIFIER ::= { modulePm1001lhr 3 } pm1001lhrMesrOther OBJECT IDENTIFIER ::= { pm1001lhrmeasures 1 } pm1001lhrMesrClient OBJECT IDENTIFIER ::= { pm1001lhrmeasures 2 } pm1001lhrMesrLine OBJECT IDENTIFIER ::= { pm1001lhrmeasures 3 } pm1001lhrcounters OBJECT IDENTIFIER ::= { modulePm1001lhr 4 } pm1001lhrCntOther OBJECT IDENTIFIER ::= { pm1001lhrcounters 1 } pm1001lhrCntClient OBJECT IDENTIFIER ::= { pm1001lhrcounters 2 } pm1001lhrCntLine OBJECT IDENTIFIER ::= { pm1001lhrcounters 3 } pm1001lhrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm1001lhr 6 } pm1001lhrCtrlOther OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 1 } pm1001lhrCtrlClient OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 2 } pm1001lhrCtrlLine OBJECT IDENTIFIER ::= { pm1001lhrcontrolsWrite 3 } pm1001lhrri OBJECT IDENTIFIER ::= { modulePm1001lhr 7 } pm1001lhrriTable OBJECT IDENTIFIER ::= { pm1001lhrri 1 } pm1001lhrdownload OBJECT IDENTIFIER ::= { modulePm1001lhr 8 } pm1001lhrDwlOther OBJECT IDENTIFIER ::= { pm1001lhrdownload 1 } pm1001lhrDwlClient OBJECT IDENTIFIER ::= { pm1001lhrdownload 2 } pm1001lhrDwlLine OBJECT IDENTIFIER ::= { pm1001lhrdownload 3 } pm1001lhrConfig OBJECT IDENTIFIER ::= { modulePm1001lhr 9 } pm1001lhrtraps OBJECT IDENTIFIER ::= { modulePm1001lhr 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** Pm1001lhrOtxMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on OTX-TLH on line ports" SYNTAX INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4), } Pm1001lhrOtxGrid ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different grids on OTX-TLH on line ports" SYNTAX INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50), } Pm1001lhrAdjustValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different values in Adjust mode on OTX-TLH on line ports" SYNTAX INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10), } Pm1001lhrOtxChannel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Channel selection on OTX-TLH on line ports" SYNTAX INTEGER { } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pm1001lhrRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pm1001lhrri 2 } pm1001lhrRinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pm1001lhrri 3 } pm1001lhrRinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pm1001lhrri 4 } pm1001lhrRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pm1001lhrri 5 } pm1001lhrRinvGwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "GW platform desciption: This OID contains the description of the Gateware platform." ::= { pm1001lhrri 6 } pm1001lhrRinvLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrRinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the XFPs on the selected module" ::= { pm1001lhrriTable 1 } pm1001lhrRinvLineEntry OBJECT-TYPE SYNTAX Pm1001lhrRinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the XFP table" INDEX { pm1001lhrRinvLineIndex } ::= { pm1001lhrRinvLineTable 1 } Pm1001lhrRinvLineEntry::= SEQUENCE { pm1001lhrRinvLineIndex Integer32, pm1001lhrRinvxfpLine DisplayString } pm1001lhrRinvLineIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for XFP table" ::= { pm1001lhrRinvLineEntry 1 } pm1001lhrRinvxfpLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the XFP: This OID contains the inventory for the XFP" ::= { pm1001lhrRinvLineEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pm1001lhrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherCrit 0 } pm1001lhrAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmsynthAlm0 16 } pm1001lhrAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmsynthAlm0 15 } pm1001lhrAlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MOD_GLOB_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001lhrAlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pm1001lhrAlmsynthAlm2 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherNurg 2 } pm1001lhrAlmCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This OID, when set, indicates that alarm correlation is not being performed. CORRELAT_OFF other (1) other (1) (2) " ::= { pm1001lhrAlmsynthAlm2 4 } pm1001lhrAlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD other (1) other (1) (2) " ::= { pm1001lhrAlmsynthAlm2 3 } pm1001lhrAlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD other (1) other (1) (2) " ::= { pm1001lhrAlmsynthAlm2 2 } pm1001lhrAlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE other (1) other (1) (2) " ::= { pm1001lhrAlmsynthAlm2 1 } --- ********************************************************* --- TABLE for the pm1001lhrAlmsynthAlmLine articles --- ********************************************************* pm1001lhrAlmsynthAlmLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmsynthAlmLine Article " ::= { pm1001lhrAlmLineCrit 7 } pm1001lhrAlmsynthAlmLineEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmsynthAlmLine table " INDEX { pm1001lhrAlmsynthAlmLineIndex } ::= { pm1001lhrAlmsynthAlmLineTable 1 } Pm1001lhrAlmsynthAlmLineEntry ::= SEQUENCE { pm1001lhrAlmsynthAlmLineIndex INTEGER, pm1001lhrAlmLineFailPortn EkiOnOff, pm1001lhrAlmLineDdmAlmPortn EkiOnOff, pm1001lhrAlmLineDdmWarningPortn EkiOnOff, pm1001lhrAlmLineLocalOosPortn EkiOnOff, pm1001lhrAlmXfpTxOffPortn EkiOnOff, pm1001lhrAlmLineHwFailPortn EkiOnOff, pm1001lhrAlmXfpInitNotComplPortn EkiOnOff, pm1001lhrAlmXfpAbsentPortn EkiOnOff } pm1001lhrAlmsynthAlmLineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmsynthAlmLine table " ::= { pm1001lhrAlmsynthAlmLineEntry 1 } pm1001lhrAlmLineFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 13 } pm1001lhrAlmLineDdmAlmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM This alarm indicates if a DDM Alarm has been detected on the line transceiver LINE_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 11 } pm1001lhrAlmLineDdmWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM This alarm indicates if a DDM Warning has been detected on the line transceiver LINE_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 10 } pm1001lhrAlmLineLocalOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) This status indicates if the line port is in service LINE_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 7 } pm1001lhrAlmXfpTxOffPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Laser Shutdown :This OID indicates the line optical output power is on This status indicates if the line transceiver laser is ON or OFF XFP_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 6 } pm1001lhrAlmLineHwFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001lhrAlmsynthAlmLineEntry 5 } pm1001lhrAlmXfpInitNotComplPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Ready :This OID indicates that the optical interface (XFP or OTX) is not operational. This status indicates if the line transceiver has been correctly initialized XFP_INIT_NOT_COMPL equipmentMalfunction (16) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001lhrAlmsynthAlmLineEntry 3 } pm1001lhrAlmXfpAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Absent :This OID indicates that the line optical interface (XFP or OTX) is not plugged in. This alarm indicates if the line transceiver is present. XFP_ABSENT inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001lhrAlmsynthAlmLineEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmdfrmAlm articles --- ********************************************************* pm1001lhrAlmdfrmAlmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmdfrmAlmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmdfrmAlm Article " ::= { pm1001lhrAlmLineCrit 128 } pm1001lhrAlmdfrmAlmEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmdfrmAlmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmdfrmAlm table " INDEX { pm1001lhrAlmdfrmAlmIndex } ::= { pm1001lhrAlmdfrmAlmTable 1 } Pm1001lhrAlmdfrmAlmEntry ::= SEQUENCE { pm1001lhrAlmdfrmAlmIndex INTEGER, pm1001lhrAlmDwLofPortn EkiOnOff, pm1001lhrAlmDwOofPortn EkiOnOff, pm1001lhrAlmDwRdiDetPortn EkiOnOff, pm1001lhrAlmDwAisDetPortn EkiOnOff } pm1001lhrAlmdfrmAlmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmdfrmAlm table " ::= { pm1001lhrAlmdfrmAlmEntry 1 } pm1001lhrAlmDwLofPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SONET/SDH Line Loss Of Frame :This OID indicates that a Loss Of Frame has been detected on incoming input signal This alarm indicates if there is a Loss of Frame is detected on the line input signal DW_LOF_1 receiveFailure (41) integrityViolation (7) (2) " ::= { pm1001lhrAlmdfrmAlmEntry 5 } pm1001lhrAlmDwOofPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SONET/SDH Line Out Of Frame :This OID indicates that an Out Of Frame has been detected on incoming input signal This alarm indicates if there is a Out of Frame is detected on the line input signal DW_OOF_1 receiveFailure (41) integrityViolation (7) (2) " ::= { pm1001lhrAlmdfrmAlmEntry 4 } pm1001lhrAlmDwRdiDetPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " MS-RDI/L-RDI Detected On Line Input :This bit indicates that an MS-RDI has been detected on incoming OC-192c/STM-64c input signal This alarm indicates if there is a MS-RDI/L-RDI is detected on the line input signal DW_RDI_DET_1 remoteNodeTransmissionError (43) other (1) (2) " ::= { pm1001lhrAlmdfrmAlmEntry 3 } pm1001lhrAlmDwAisDetPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " MS-AIS/L-AIS Detected On Line Input :This bit indicates that an MS-AIS has been detected on incoming OC-192c/STM-64c input signal This alarm indicates if there is a MS-AIS/L-AIS is detected on the line input signal DW_AIS_DET_1 receiveFailure (41) operationalViolation (8) (2) " ::= { pm1001lhrAlmdfrmAlmEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmdfrmBer articles --- ********************************************************* pm1001lhrAlmdfrmBerTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmdfrmBerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmdfrmBer Article " ::= { pm1001lhrAlmLineUrg 129 } pm1001lhrAlmdfrmBerEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmdfrmBerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmdfrmBer table " INDEX { pm1001lhrAlmdfrmBerIndex } ::= { pm1001lhrAlmdfrmBerTable 1 } Pm1001lhrAlmdfrmBerEntry ::= SEQUENCE { pm1001lhrAlmdfrmBerIndex INTEGER, pm1001lhrAlmLineDegradePortn EkiOnOff, pm1001lhrAlmLineSignalFailPortn EkiOnOff, pm1001lhrAlmLineSignalDegradePortn EkiOnOff } pm1001lhrAlmdfrmBerIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmdfrmBer table " ::= { pm1001lhrAlmdfrmBerEntry 1 } pm1001lhrAlmLineDegradePortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fixed Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assetion hysteresis is fixed to 10-8 (assertion) and 10-9 (de-assertion) LINE_DEGRADE_1 degradedSignal (13) qualityOfServiceAlarm (3) (2) " ::= { pm1001lhrAlmdfrmBerEntry 6 } pm1001lhrAlmLineSignalFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Custom Line Signal Fail :This OID indicates that the line input signal is FAIL. The assertion hysteresis can be customized by the host LINE_SIGNAL_FAIL_1 receiveFailure (41) integrityViolation (7) (2) " ::= { pm1001lhrAlmdfrmBerEntry 3 } pm1001lhrAlmLineSignalDegradePortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Custom Line Signal Degrade :This OID indicates that the line input signal is DEGRADE. The assertion hysteresis can customized by the host LINE_SIGNAL_DEGRADE_1 degradedSignal (13) qualityOfServiceAlarm (3) (2) " ::= { pm1001lhrAlmdfrmBerEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineSyncAlarms articles --- ********************************************************* pm1001lhrAlmlineSyncAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineSyncAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineSyncAlarms Article " ::= { pm1001lhrAlmLineCrit 133 } pm1001lhrAlmlineSyncAlarmsEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineSyncAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineSyncAlarms table " INDEX { pm1001lhrAlmlineSyncAlarmsIndex } ::= { pm1001lhrAlmlineSyncAlarmsTable 1 } Pm1001lhrAlmlineSyncAlarmsEntry ::= SEQUENCE { pm1001lhrAlmlineSyncAlarmsIndex INTEGER, pm1001lhrAlmDwLosPortn EkiOnOff, pm1001lhrAlmUpLockerrPortn EkiOnOff, pm1001lhrAlmDwLockerrPortn EkiOnOff } pm1001lhrAlmlineSyncAlarmsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineSyncAlarms table " ::= { pm1001lhrAlmlineSyncAlarmsEntry 1 } pm1001lhrAlmDwLosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Input Loss Of Signal :This OID indicates a loss of signal on the 10 Gb/s input. This alarm indicates if an optical signal is detected on the line transceiver input DW_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pm1001lhrAlmlineSyncAlarmsEntry 17 } pm1001lhrAlmUpLockerrPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Upstream Clock Lock Error :This OID indicates that the serializer output 10 Gb/s clock multiplier unit is not locked. UP_LOCKERR receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineSyncAlarmsEntry 14 } pm1001lhrAlmDwLockerrPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Downstream Clock Lock Error :This OID indicates that the deserializer input 10 Gb/s clock recovery is not locked. DW_LOCKERR receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineSyncAlarmsEntry 13 } --- ***************************************************** --- LEAF for the modInitFailLevel2 article --- ***************************************************** pm1001lhrAlmmodInitFailLevel2 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherUrg 194 } pm1001lhrAlmSwInitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW Init Fail :This OID indicates that the SW intialization has caused unknown intial conditions This alarm indicates if the SW module is correctly initialized SW_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel2 5 } pm1001lhrAlmResetHwInitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Reset HW Init Fail :This OID indicates that the HW intialization has caused unknown intial conditions This alarm indicates if the HW has been correctly initialized RESET_HW_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel2 4 } pm1001lhrAlmBootUndone OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Boot Undone :This OID indicates that the boot has not been correctly achieved This alarm indicates if the module has correctly boot BOOT_UNDONE softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel2 3 } pm1001lhrAlmNextColdBootForced OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Next Cold Boot Forced :This OID indicates that the next Reset will be forced Cold This alarm indicates that the next reset of the module will be forced to cold reset NEXT_COLD_BOOT_FORCED informationalStatus(1000) other (1) (2) " ::= { pm1001lhrAlmmodInitFailLevel2 2 } pm1001lhrAlmLedFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Led Fail :This OID indicates that Led register has not been correctly initalized This alarm indicates if the module LEDs are correctly initialized LED_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel2 1 } --- ***************************************************** --- LEAF for the modInitFailLevel3 article --- ***************************************************** pm1001lhrAlmmodInitFailLevel3 OBJECT IDENTIFIER ::= { pm1001lhrAlmOtherUrg 195 } pm1001lhrAlmLine2InitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line2 Init Fail :This OID indicates that the Line register subset has not been correctly initialized This alarm indicates if the line port 2 is correctly initialized LINE2_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 8 } pm1001lhrAlmLine1InitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line1 Init Fail :This OID indicates that the Line registersvsubset has not been correctly initialized This alarm indicates if the line port 1 is correctly initialized LINE1_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 7 } pm1001lhrAlmXfp2InitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " XFP2 Init Fail :This OID indicates that the XFP has not been correctly initialized This alarm indicates if the line transceiver 2 is correctly initialized XFP2_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 6 } pm1001lhrAlmXfp1InitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " XFP1 Init Fail :This OID indicates that the XFP has not been correctly initialized This alarm indicates if the line transceiver 1 is correctly initialized XFP1_INIT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 5 } pm1001lhrAlmInitModuleFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Init Module Fail :This OID indicates that the Module has not been correctly initialized This alarm indicates if the SW module is correctly initialized INIT_MODULE_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 3 } pm1001lhrAlmObmTypeReadFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OBM Type Read Fail :This OID indicates that OBM type has not been recognized This alarm indicates if the OBM board has been correctly identified OBM_TYPE_READ_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 2 } pm1001lhrAlmGwIdentFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW Ident Fail :This OID indicates that GW identification has not been read This alarm indicates if the GW has been correctly identified GW_IDENT_FAIL softwareError (47) processingErrorAlarm (4) (2) " ::= { pm1001lhrAlmmodInitFailLevel3 1 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineXfp1Alarm articles --- ********************************************************* pm1001lhrAlmlineXfp1AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineXfp1Alarm Article " ::= { pm1001lhrAlmLineUrg 208 } pm1001lhrAlmlineXfp1AlarmEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineXfp1AlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineXfp1Alarm table " INDEX { pm1001lhrAlmlineXfp1AlarmIndex } ::= { pm1001lhrAlmlineXfp1AlarmTable 1 } Pm1001lhrAlmlineXfp1AlarmEntry ::= SEQUENCE { pm1001lhrAlmlineXfp1AlarmIndex INTEGER, pm1001lhrAlmRxPowerHighAlarmPortn EkiOnOff, pm1001lhrAlmRxPowerLowAlarmPortn EkiOnOff, pm1001lhrAlmTempHighAlarmPortn EkiOnOff, pm1001lhrAlmTempLowAlarmPortn EkiOnOff, pm1001lhrAlmTxBiasHighAlarmPortn EkiOnOff, pm1001lhrAlmTxBiasLowAlarmPortn EkiOnOff, pm1001lhrAlmTxPowerHighAlarmPortn EkiOnOff, pm1001lhrAlmTxPowerLowAlarmPortn EkiOnOff } pm1001lhrAlmlineXfp1AlarmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineXfp1Alarm table " ::= { pm1001lhrAlmlineXfp1AlarmEntry 1 } pm1001lhrAlmRxPowerHighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx Power High :Alarm indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM RX_POWER_HIGH_ALARM_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 17 } pm1001lhrAlmRxPowerLowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx Power Low :Alarm indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM RX_POWER_LOW_ALARM_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 16 } pm1001lhrAlmTempHighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Temp High :Alarm indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM TEMP_HIGH_ALARM_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 9 } pm1001lhrAlmTempLowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Temp Low :Alarm indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM TEMP_LOW_ALARM_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 8 } pm1001lhrAlmTxBiasHighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Bias High :Alarm indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM TX_BIAS_HIGH_ALARM_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 5 } pm1001lhrAlmTxBiasLowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Bias Low :Alarm indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM TX_BIAS_LOW_ALARM_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 4 } pm1001lhrAlmTxPowerHighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Power High :Alarm indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM TX_POWER_HIGH_ALARM_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 3 } pm1001lhrAlmTxPowerLowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Power Low :Alarm indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPROM TX_POWER_LOW_ALARM_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineXfp1Warnings articles --- ********************************************************* pm1001lhrAlmlineXfp1WarningsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1WarningsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineXfp1Warnings Article " ::= { pm1001lhrAlmLineNurg 209 } pm1001lhrAlmlineXfp1WarningsEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineXfp1WarningsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineXfp1Warnings table " INDEX { pm1001lhrAlmlineXfp1WarningsIndex } ::= { pm1001lhrAlmlineXfp1WarningsTable 1 } Pm1001lhrAlmlineXfp1WarningsEntry ::= SEQUENCE { pm1001lhrAlmlineXfp1WarningsIndex INTEGER, pm1001lhrAlmRxPowerHighWarningPortn EkiOnOff, pm1001lhrAlmRxPowerLowWarningPortn EkiOnOff, pm1001lhrAlmTempHighWarningPortn EkiOnOff, pm1001lhrAlmTempLowWarningPortn EkiOnOff, pm1001lhrAlmTxBiasHighWarningPortn EkiOnOff, pm1001lhrAlmTxBiasLowWarningPortn EkiOnOff, pm1001lhrAlmTxPowerHighWarningPortn EkiOnOff, pm1001lhrAlmTxPowerLowWarningPortn EkiOnOff } pm1001lhrAlmlineXfp1WarningsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineXfp1Warnings table " ::= { pm1001lhrAlmlineXfp1WarningsEntry 1 } pm1001lhrAlmRxPowerHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx Power High Warning :Warning indicating that the XFP received optical power is higher than the threshold value written in the XFP EEPROM RX_POWER_HIGH_WARNING_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 17 } pm1001lhrAlmRxPowerLowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx Power Low Warning :Warning indicating that the XFP received optical power is lower than the threshold value written in the XFP EEPROM RX_POWER_LOW_WARNING_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 16 } pm1001lhrAlmTempHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Temp High Warning :Warning indicating that the XFP/OTX temperature is higher than the threshold value written in the XFP EEPROM TEMP_HIGH_WARNING_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 9 } pm1001lhrAlmTempLowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Temp Low Warning :Warning indicating that the XFP/OTX temperature is lower than the threshold value written in the XFP/OTX EEPROM TEMP_LOW_WARNING_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 8 } pm1001lhrAlmTxBiasHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Bias High Warning :Warning indicating that the XFP/OTX transmitter laser bias current is higher than the threshold value written in the XFP EEPROM TX_BIAS_HIGH_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 5 } pm1001lhrAlmTxBiasLowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Transceiver Bias Low Warning :Warning indicating that the XFP/OTX transmitter laser bias current is lower than the threshold value written in the XFP/OTX EEPROM TX_BIAS_LOW_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 4 } pm1001lhrAlmTxPowerHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Power High Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is higher than the threshold value written in the XFP EEPROM TX_POWER_HIGH_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 3 } pm1001lhrAlmTxPowerLowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Power Low Warning :Warning indicating that the XFP/OTX transmitter transmitter output power is lower than the threshold value written in the XFP/OTX EEPROM TX_POWER_LOW_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1WarningsEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineXfp1Alarms articles --- ********************************************************* pm1001lhrAlmlineXfp1AlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1AlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineXfp1Alarms Article " ::= { pm1001lhrAlmLineCrit 211 } pm1001lhrAlmlineXfp1AlarmsEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineXfp1AlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineXfp1Alarms table " INDEX { pm1001lhrAlmlineXfp1AlarmsIndex } ::= { pm1001lhrAlmlineXfp1AlarmsTable 1 } Pm1001lhrAlmlineXfp1AlarmsEntry ::= SEQUENCE { pm1001lhrAlmlineXfp1AlarmsIndex INTEGER, pm1001lhrAlmApdSupplyFaultPortn EkiOnOff, pm1001lhrAlmTecFaultPortn EkiOnOff, pm1001lhrAlmWavelengthUnlockedPortn EkiOnOff, pm1001lhrAlmTxNrPortn EkiOnOff, pm1001lhrAlmTxFaultPortn EkiOnOff, pm1001lhrAlmTxCdrNotLockedPortn EkiOnOff, pm1001lhrAlmRxNrPortn EkiOnOff, pm1001lhrAlmRxCdrNotLockedPortn EkiOnOff, pm1001lhrAlmModNrPortn EkiOnOff } pm1001lhrAlmlineXfp1AlarmsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineXfp1Alarms table " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 1 } pm1001lhrAlmApdSupplyFaultPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Rx Photodiode Power Failed :This OID indicates a failure on the APD power supply This alarm indicates if the APD power supply is in fail condition APD_SUPPLY_FAULT_1 receiverFailure (42) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 17 } pm1001lhrAlmTecFaultPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Temp Regul Failed :This OID indicates a failure on the TEC module This alarm indicates if the TEC of the line transceiver is in fail condition TEC_FAULT_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 16 } pm1001lhrAlmWavelengthUnlockedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Wavelength Unlocked :This OID indicates that the wavelength error is exceeding the manufacturer tolerance This alarm indicates if the wavelenght of the line transceiver is locked WAVELENGTH_UNLOCKED_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 15 } pm1001lhrAlmTxNrPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the transmitting side This alarm indicates if the Tx part of the line transceiver is ready TX_NR_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 9 } pm1001lhrAlmTxFaultPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx Failure :This OID indicates a fault condition on the laser detected by the safety syste This alarm indicates if the laser of the line transceiver is in fail condition TX_FAULT_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 8 } pm1001lhrAlmTxCdrNotLockedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Tx CDR Unlocked :This OID indicates a loss of lock on the transmitting side CDR has been detected. This alarm indicates if the Tx CDR is locked in the line transceiver TX_CDR_NOT_LOCKED1_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 7 } pm1001lhrAlmRxNrPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the receiving side. This alarm indicates if the Rx part of the line transceiver is ready RX_NR_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 6 } pm1001lhrAlmRxCdrNotLockedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the receiving side CDR has been detected This alarm indicates if the Rx CDR is locked in the line transceiver RX_CDR_NOT_LOCKED1_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 4 } pm1001lhrAlmModNrPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Not Ready :This OID indicates that the module is unable to determine correct data. This alarm indicates if the line transceiver is ready MOD_NR_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1AlarmsEntry 3 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineXfp1SupplyAlarm articles --- ********************************************************* pm1001lhrAlmlineXfp1SupplyAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineXfp1SupplyAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineXfp1SupplyAlarm Article " ::= { pm1001lhrAlmLineUrg 212 } pm1001lhrAlmlineXfp1SupplyAlarmEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineXfp1SupplyAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineXfp1SupplyAlarm table " INDEX { pm1001lhrAlmlineXfp1SupplyAlarmIndex } ::= { pm1001lhrAlmlineXfp1SupplyAlarmTable 1 } Pm1001lhrAlmlineXfp1SupplyAlarmEntry ::= SEQUENCE { pm1001lhrAlmlineXfp1SupplyAlarmIndex INTEGER, pm1001lhrAlmVcc5HighWarningPortn EkiOnOff, pm1001lhrAlmVcc5LowWarningPortn EkiOnOff, pm1001lhrAlmVcc3HighWarningPortn EkiOnOff, pm1001lhrAlmVcc3LowWarningPortn EkiOnOff, pm1001lhrAlmVcc2HighWarningPortn EkiOnOff, pm1001lhrAlmVcc2LowWarningPortn EkiOnOff, pm1001lhrAlmVee5HighWarningPortn EkiOnOff, pm1001lhrAlmVee5LowWarningPortn EkiOnOff, pm1001lhrAlmVcc5HighAlarmPortn EkiOnOff, pm1001lhrAlmVcc5LowAlarmPortn EkiOnOff, pm1001lhrAlmVcc3HighAlarmPortn EkiOnOff, pm1001lhrAlmVcc3LowAlarmPortn EkiOnOff, pm1001lhrAlmVcc2HighAlarmPortn EkiOnOff, pm1001lhrAlmVcc2LowAlarmPortn EkiOnOff, pm1001lhrAlmVee5HighAlarmPortn EkiOnOff, pm1001lhrAlmVee5LowAlarmPortn EkiOnOff } pm1001lhrAlmlineXfp1SupplyAlarmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineXfp1SupplyAlarm table " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 1 } pm1001lhrAlmVcc5HighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC5 Power Supply High Warning :Warning indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM VCC5_HIGH_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 17 } pm1001lhrAlmVcc5LowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC5 Power Supply Low Warning :Warning indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM VCC5_LOW_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 16 } pm1001lhrAlmVcc3HighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC3 Power Supply High Warning :Warning indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM VCC3_HIGH_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 15 } pm1001lhrAlmVcc3LowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC3 Power Supply Low Warning :Warning indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM VCC3_LOW_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 14 } pm1001lhrAlmVcc2HighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC2 Power Supply High Warning :Warning indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM VCC2_HIGH_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 13 } pm1001lhrAlmVcc2LowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC2 Power Supply Low Warning :Warning indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM VCC2_LOW_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 12 } pm1001lhrAlmVee5HighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VEE5 Power Supply High Warning :Warning indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM VEE5_HIGH_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 11 } pm1001lhrAlmVee5LowWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VEE5 Power Supply Low Warning :Warning indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM VEE5_LOW_WARNING_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 10 } pm1001lhrAlmVcc5HighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC5 Power Supply High :Alarm indicating the XFP/OTX VCC5 power supply is higher than the threshold written in the EEPROM VCC5_HIGH_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 9 } pm1001lhrAlmVcc5LowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC5 Power Supply Low :Alarm indicating the XFP/OTX VCC5 power supply is lower than the threshold written in the EEPROM VCC5_LOW_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 8 } pm1001lhrAlmVcc3HighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC3 Power Supply High :Alarm indicating the XFP/OTX VCC3 power supply is higher than the threshold written in the EEPROM VCC3_HIGH_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 7 } pm1001lhrAlmVcc3LowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC3 Power Supply Low :Alarm indicating the XFP/OTX VCC3 power supply is lower than the threshold written in the EEPROM VCC3_LOW_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 6 } pm1001lhrAlmVcc2HighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC2 Power Supply High :Alarm indicating the XFP/OTX VCC2 power supply is higher than the threshold written in the EEPROM VCC2_HIGH_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 5 } pm1001lhrAlmVcc2LowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VCC2 Power Supply Low :Alarm indicating the XFP/OTX VCC2 power supply is lower than the threshold written in the EEPROM VCC2_LOW_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 4 } pm1001lhrAlmVee5HighAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VEE5 Power Supply High :Alarm indicating the XFP/OTX VEE5 power supply is higher than the threshold written in the EEPROM VEE5_HIGH_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 3 } pm1001lhrAlmVee5LowAlarmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " VEE5 Power Supply Low :Alarm indicating the XFP/OTX VEE5 power supply is lower than the threshold written in the EEPROM VEE5_LOW_ALARM_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineXfp1SupplyAlarmEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineOtx1TlhAlarms articles --- ********************************************************* pm1001lhrAlmlineOtx1TlhAlarmsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineOtx1TlhAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineOtx1TlhAlarms Article " ::= { pm1001lhrAlmLineUrg 224 } pm1001lhrAlmlineOtx1TlhAlarmsEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineOtx1TlhAlarmsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineOtx1TlhAlarms table " INDEX { pm1001lhrAlmlineOtx1TlhAlarmsIndex } ::= { pm1001lhrAlmlineOtx1TlhAlarmsTable 1 } Pm1001lhrAlmlineOtx1TlhAlarmsEntry ::= SEQUENCE { pm1001lhrAlmlineOtx1TlhAlarmsIndex INTEGER, pm1001lhrAlmLineLaserTempHighAlaPortn EkiOnOff, pm1001lhrAlmLineFreqDevHighAlaPortn EkiOnOff, pm1001lhrAlmLineAgingHighAlaPortn EkiOnOff, pm1001lhrAlmLineModulatorAgingHighAlaPortn EkiOnOff } pm1001lhrAlmlineOtx1TlhAlarmsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineOtx1TlhAlarms table " ::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 1 } pm1001lhrAlmLineLaserTempHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Laser Temp. High Alarm :Alarm indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM LINE_LASER_TEMP_HIGH_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 15 } pm1001lhrAlmLineFreqDevHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Freq. Deviation High Alarm :Alarm indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM LINE_FREQ_DEV_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 13 } pm1001lhrAlmLineAgingHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line OTX TLH Aging High Alarm :Alarm indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM LINE_AGING_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 7 } pm1001lhrAlmLineModulatorAgingHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Modulator Aging High Alarm :Alarm indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM LINE_MODULATOR_AGING_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhAlarmsEntry 6 } --- ********************************************************* --- TABLE for the pm1001lhrAlmlineOtx1TlhWarnings articles --- ********************************************************* pm1001lhrAlmlineOtx1TlhWarningsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrAlmlineOtx1TlhWarningsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrAlmlineOtx1TlhWarnings Article " ::= { pm1001lhrAlmLineNurg 225 } pm1001lhrAlmlineOtx1TlhWarningsEntry OBJECT-TYPE SYNTAX Pm1001lhrAlmlineOtx1TlhWarningsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrAlmlineOtx1TlhWarnings table " INDEX { pm1001lhrAlmlineOtx1TlhWarningsIndex } ::= { pm1001lhrAlmlineOtx1TlhWarningsTable 1 } Pm1001lhrAlmlineOtx1TlhWarningsEntry ::= SEQUENCE { pm1001lhrAlmlineOtx1TlhWarningsIndex INTEGER, pm1001lhrAlmLineLaserTempHighWarningPortn EkiOnOff, pm1001lhrAlmLineFreqDevHighWarningPortn EkiOnOff, pm1001lhrAlmLineAgingHighWarningPortn EkiOnOff, pm1001lhrAlmLineModulatorAgingHighWarningPortn EkiOnOff } pm1001lhrAlmlineOtx1TlhWarningsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrAlmlineOtx1TlhWarnings table " ::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 1 } pm1001lhrAlmLineLaserTempHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Laser Temp. High Warning :Warning indicating the Line OTX TLH laser temperature is higher than the threshold written in the EEPROM LINE_LASER_TEMP_HIGH_WARNING_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 15 } pm1001lhrAlmLineFreqDevHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Freq. Deviation High Warning :Warning indicating the Line OTX TLH frequency deviation is higher than the threshold written in the EEPROM LINE_FREQ_DEV_HIGH_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 13 } pm1001lhrAlmLineAgingHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line OTX TLH Aging High Warning :Warning indicating the Line OTX TLH aging is higher than the threshold written in the EEPROM LINE_AGING_HIGH_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 7 } pm1001lhrAlmLineModulatorAgingHighWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Modulator Aging High Warning :Warning indicating the Line OTX TLH modulator aging is higher than the threshold written in the EEPROM LINE_MODULATOR_AGING_HIGH_WARNING_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001lhrAlmlineOtx1TlhWarningsEntry 6 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the confMgnt1 article --- ***************************************************** pm1001lhrCtrlconfMgnt1 OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 1 } pm1001lhrCtrlConf2Clear1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. This control restores the default configuration of the module " ::= { pm1001lhrCtrlconfMgnt1 14 } pm1001lhrCtrlConf2Flash1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. This control saves the customer configuration on the module " ::= { pm1001lhrCtrlconfMgnt1 10 } pm1001lhrCtrlConf2Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. " ::= { pm1001lhrCtrlconfMgnt1 2 } pm1001lhrCtrlConf1Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. " ::= { pm1001lhrCtrlconfMgnt1 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pm1001lhrCtrlsynth4 OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 4 } pm1001lhrCtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM. " ::= { pm1001lhrCtrlsynth4 2 } pm1001lhrCtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM. " ::= { pm1001lhrCtrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pm1001lhrCtrlswMgnt OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 5 } pm1001lhrCtrlLoadSwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. This controls selects the second SW bank as the active bank for the next module reset " ::= { pm1001lhrCtrlswMgnt 6 } pm1001lhrCtrlLoadSwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. This controls selects the first SW bank as the active bank for the next module reset " ::= { pm1001lhrCtrlswMgnt 5 } pm1001lhrCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. This control initiates a warm reset of the module. " ::= { pm1001lhrCtrlswMgnt 3 } pm1001lhrCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pm1001lhrCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the gwMgnt article --- ***************************************************** pm1001lhrCtrlgwMgnt OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 6 } pm1001lhrCtrlLoadGwBank4 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pm1001lhrCtrlgwMgnt 8 } pm1001lhrCtrlLoadGwBank3 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the third GW bank as the active bank " ::= { pm1001lhrCtrlgwMgnt 7 } pm1001lhrCtrlLoadGwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pm1001lhrCtrlgwMgnt 6 } pm1001lhrCtrlLoadGwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the first GW bank as the active bank " ::= { pm1001lhrCtrlgwMgnt 5 } pm1001lhrCtrlCurrentGwReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. " ::= { pm1001lhrCtrlgwMgnt 1 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlaccessLoop articles --- ********************************************************* pm1001lhrCtrlaccessLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlaccessLoop Article " ::= { pm1001lhrCtrlClient 16 } pm1001lhrCtrlaccessLoopEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlaccessLoop table " INDEX { pm1001lhrCtrlaccessLoopIndex } ::= { pm1001lhrCtrlaccessLoopTable 1 } Pm1001lhrCtrlaccessLoopEntry ::= SEQUENCE { pm1001lhrCtrlaccessLoopIndex INTEGER, pm1001lhrCtrlaccessLoopPortn EkiState } pm1001lhrCtrlaccessLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlaccessLoop table " ::= { pm1001lhrCtrlaccessLoopEntry 1 } pm1001lhrCtrlaccessLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Facility Loopback :This OID operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the client transceiver This maintenance parameter operates a Client Facility Loopback, looping client input signal on the client output port. The loop is located on the client transceiver " ::= { pm1001lhrCtrlaccessLoopEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlclientAccessTermLoop articles --- ********************************************************* pm1001lhrCtrlclientAccessTermLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlclientAccessTermLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlclientAccessTermLoop Article " ::= { pm1001lhrCtrlClient 26 } pm1001lhrCtrlclientAccessTermLoopEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlclientAccessTermLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlclientAccessTermLoop table " INDEX { pm1001lhrCtrlclientAccessTermLoopIndex } ::= { pm1001lhrCtrlclientAccessTermLoopTable 1 } Pm1001lhrCtrlclientAccessTermLoopEntry ::= SEQUENCE { pm1001lhrCtrlclientAccessTermLoopIndex INTEGER, pm1001lhrCtrlclientAccessTermLoopPortn EkiState } pm1001lhrCtrlclientAccessTermLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlclientAccessTermLoop table " ::= { pm1001lhrCtrlclientAccessTermLoopEntry 1 } pm1001lhrCtrlclientAccessTermLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Terminal Loopback :This OID operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line transceiver This maintenance parameter operates a Client Terminal Loopback, looping client input signal on the client output port. The loop is located on the line transceiver " ::= { pm1001lhrCtrlclientAccessTermLoopEntry 2 } pm1001lhrCtrlprotocol OBJECT-TYPE SYNTAX EkiProtocol MAX-ACCESS read-write STATUS current DESCRIPTION " Client Protocol :This OID sets the protocol on the PM " ::= { pm1001lhrCtrlLine 52 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlfecDisable articles --- ********************************************************* pm1001lhrCtrlfecDisableTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlfecDisable Article " ::= { pm1001lhrCtrlLine 69 } pm1001lhrCtrlfecDisableEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlfecDisable table " INDEX { pm1001lhrCtrlfecDisableIndex } ::= { pm1001lhrCtrlfecDisableTable 1 } Pm1001lhrCtrlfecDisableEntry ::= SEQUENCE { pm1001lhrCtrlfecDisableIndex INTEGER, pm1001lhrCtrlfecDisablePortn EkiState } pm1001lhrCtrlfecDisableIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlfecDisable table " ::= { pm1001lhrCtrlfecDisableEntry 1 } pm1001lhrCtrlfecDisablePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input This control disables the Forward Error Correction on the line input signal. " ::= { pm1001lhrCtrlfecDisableEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrllineOosMode articles --- ********************************************************* pm1001lhrCtrllineOosModeTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrllineOosModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrllineOosMode Article " ::= { pm1001lhrCtrlLine 74 } pm1001lhrCtrllineOosModeEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrllineOosModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrllineOosMode table " INDEX { pm1001lhrCtrllineOosModeIndex } ::= { pm1001lhrCtrllineOosModeTable 1 } Pm1001lhrCtrllineOosModeEntry ::= SEQUENCE { pm1001lhrCtrllineOosModeIndex INTEGER, pm1001lhrCtrllineOosModePortn EkiState } pm1001lhrCtrllineOosModeIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrllineOosMode table " ::= { pm1001lhrCtrllineOosModeEntry 1 } pm1001lhrCtrllineOosModePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Port Out Of Service :This OID sets the line port Out Of Service " ::= { pm1001lhrCtrllineOosModeEntry 2 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pm1001lhrCtrlledTest OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 192 } pm1001lhrCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pm1001lhrCtrlledTest 3 } pm1001lhrCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pm1001lhrCtrlledTest 2 } pm1001lhrCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pm1001lhrCtrlledTest 1 } --- ***************************************************** --- LEAF for the moduleOosMode article --- ***************************************************** pm1001lhrCtrlmoduleOosMode OBJECT IDENTIFIER ::= { pm1001lhrCtrlOther 193 } pm1001lhrCtrlModuleOosMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Out Of Service :This OID sets the PM1008 Out Of Service This control defines the service state of the complete module " ::= { pm1001lhrCtrlmoduleOosMode 1 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlxfpOnoff articles --- ********************************************************* pm1001lhrCtrlxfpOnoffTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpOnoffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlxfpOnoff Article " ::= { pm1001lhrCtrlLine 208 } pm1001lhrCtrlxfpOnoffEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlxfpOnoffEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlxfpOnoff table " INDEX { pm1001lhrCtrlxfpOnoffIndex } ::= { pm1001lhrCtrlxfpOnoffTable 1 } Pm1001lhrCtrlxfpOnoffEntry ::= SEQUENCE { pm1001lhrCtrlxfpOnoffIndex INTEGER, pm1001lhrCtrlxfpOnoffPortn EkiState } pm1001lhrCtrlxfpOnoffIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlxfpOnoff table " ::= { pm1001lhrCtrlxfpOnoffEntry 1 } pm1001lhrCtrlxfpOnoffPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Optical Laser Shutdown :This OID switches off the XFP or the OTX This control defines the laser state of the line transceiver " ::= { pm1001lhrCtrlxfpOnoffEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlxfpLineLoop articles --- ********************************************************* pm1001lhrCtrlxfpLineLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpLineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlxfpLineLoop Article " ::= { pm1001lhrCtrlLine 209 } pm1001lhrCtrlxfpLineLoopEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlxfpLineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlxfpLineLoop table " INDEX { pm1001lhrCtrlxfpLineLoopIndex } ::= { pm1001lhrCtrlxfpLineLoopTable 1 } Pm1001lhrCtrlxfpLineLoopEntry ::= SEQUENCE { pm1001lhrCtrlxfpLineLoopIndex INTEGER, pm1001lhrCtrlxfpLineLoopPortn EkiState } pm1001lhrCtrlxfpLineLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlxfpLineLoop table " ::= { pm1001lhrCtrlxfpLineLoopEntry 1 } pm1001lhrCtrlxfpLineLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Facility Loopback :This OID operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transceiver. If the Line signal carries DCC, the management network is impacted This maintenance parameter operates a Line Facility Loopback, looping line input signal on the line output port. The loop is located on the line transceiver. If the Line signal carries DCC, the management network is impacted " ::= { pm1001lhrCtrlxfpLineLoopEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrlxfpXfiLoop articles --- ********************************************************* pm1001lhrCtrlxfpXfiLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrlxfpXfiLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrlxfpXfiLoop Article " ::= { pm1001lhrCtrlLine 210 } pm1001lhrCtrlxfpXfiLoopEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrlxfpXfiLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrlxfpXfiLoop table " INDEX { pm1001lhrCtrlxfpXfiLoopIndex } ::= { pm1001lhrCtrlxfpXfiLoopTable 1 } Pm1001lhrCtrlxfpXfiLoopEntry ::= SEQUENCE { pm1001lhrCtrlxfpXfiLoopIndex INTEGER, pm1001lhrCtrlxfpXfiLoopPortn EkiState } pm1001lhrCtrlxfpXfiLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrlxfpXfiLoop table " ::= { pm1001lhrCtrlxfpXfiLoopEntry 1 } pm1001lhrCtrlxfpXfiLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Terminal Loopback :This OID operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transceivers This maintenance parameter operates a Line Terminal Loopback, looping line input signal on the line output port. The loop is located on all client transceivers. " ::= { pm1001lhrCtrlxfpXfiLoopEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrllineTunableChannel articles --- ********************************************************* pm1001lhrCtrllineTunableChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrllineTunableChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrllineTunableChannel Article " ::= { pm1001lhrCtrlLine 212 } pm1001lhrCtrllineTunableChannelEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrllineTunableChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrllineTunableChannel table " INDEX { pm1001lhrCtrllineTunableChannelIndex } ::= { pm1001lhrCtrllineTunableChannelTable 1 } Pm1001lhrCtrllineTunableChannelEntry ::= SEQUENCE { pm1001lhrCtrllineTunableChannelIndex INTEGER, pm1001lhrCtrllineTunableChannelPortn Pm1001lhrOtxChannel } pm1001lhrCtrllineTunableChannelIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrllineTunableChannel table " ::= { pm1001lhrCtrllineTunableChannelEntry 1 } pm1001lhrCtrllineTunableChannelPortn OBJECT-TYPE SYNTAX Pm1001lhrOtxChannel MAX-ACCESS read-write STATUS current DESCRIPTION " ITU Channel :This OID selects the ITU channel of the Line OTX TLH Laser This control defines the ITU channel of the Line OTX TLH Laser " ::= { pm1001lhrCtrllineTunableChannelEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrllinePhotodiodeMode articles --- ********************************************************* pm1001lhrCtrllinePhotodiodeModeTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrllinePhotodiodeModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrllinePhotodiodeMode Article " ::= { pm1001lhrCtrlLine 213 } pm1001lhrCtrllinePhotodiodeModeEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrllinePhotodiodeModeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrllinePhotodiodeMode table " INDEX { pm1001lhrCtrllinePhotodiodeModeIndex } ::= { pm1001lhrCtrllinePhotodiodeModeTable 1 } Pm1001lhrCtrllinePhotodiodeModeEntry ::= SEQUENCE { pm1001lhrCtrllinePhotodiodeModeIndex INTEGER, pm1001lhrCtrllinePhotodiodeModePortn Pm1001lhrOtxMode } pm1001lhrCtrllinePhotodiodeModeIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrllinePhotodiodeMode table " ::= { pm1001lhrCtrllinePhotodiodeModeEntry 1 } pm1001lhrCtrllinePhotodiodeModePortn OBJECT-TYPE SYNTAX Pm1001lhrOtxMode MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line OTX TLH This control defines the receiver sensibility mode of the Line OTX TLH Laser (OTX60, OTX80 or Custom) " ::= { pm1001lhrCtrllinePhotodiodeModeEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrllinePhotodiodeValue articles --- ********************************************************* pm1001lhrCtrllinePhotodiodeValueTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrllinePhotodiodeValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrllinePhotodiodeValue Article " ::= { pm1001lhrCtrlLine 214 } pm1001lhrCtrllinePhotodiodeValueEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrllinePhotodiodeValueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrllinePhotodiodeValue table " INDEX { pm1001lhrCtrllinePhotodiodeValueIndex } ::= { pm1001lhrCtrllinePhotodiodeValueTable 1 } Pm1001lhrCtrllinePhotodiodeValueEntry ::= SEQUENCE { pm1001lhrCtrllinePhotodiodeValueIndex INTEGER, pm1001lhrCtrllinePhotodiodeValuePortn Pm1001lhrAdjustValue } pm1001lhrCtrllinePhotodiodeValueIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrllinePhotodiodeValue table " ::= { pm1001lhrCtrllinePhotodiodeValueEntry 1 } pm1001lhrCtrllinePhotodiodeValuePortn OBJECT-TYPE SYNTAX Pm1001lhrAdjustValue MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line OTX TLH (custom mode only) This control defines the receiver sensibility value (only in Custom mode) of the Line OTX TLH Laser " ::= { pm1001lhrCtrllinePhotodiodeValueEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrCtrllinePowerLaser articles --- ********************************************************* pm1001lhrCtrllinePowerLaserTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCtrllinePowerLaserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCtrllinePowerLaser Article " ::= { pm1001lhrCtrlLine 215 } pm1001lhrCtrllinePowerLaserEntry OBJECT-TYPE SYNTAX Pm1001lhrCtrllinePowerLaserEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCtrllinePowerLaser table " INDEX { pm1001lhrCtrllinePowerLaserIndex } ::= { pm1001lhrCtrllinePowerLaserTable 1 } Pm1001lhrCtrllinePowerLaserEntry ::= SEQUENCE { pm1001lhrCtrllinePowerLaserIndex INTEGER, pm1001lhrCtrllinePowerLaserPortn INTEGER } pm1001lhrCtrllinePowerLaserIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCtrllinePowerLaser table " ::= { pm1001lhrCtrllinePowerLaserEntry 1 } pm1001lhrCtrllinePowerLaserPortn OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line OTX TLH (AV=Power*10+158) (Unit = dBm) This control defines the start-up output power of the Line OTX TLH " ::= { pm1001lhrCtrllinePowerLaserEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- COUNTERS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pm1001lhrCntdfrmB1ErrCnt articles --- ********************************************************* pm1001lhrCntdfrmB1ErrCntTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCntdfrmB1ErrCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCntdfrmB1ErrCnt Article " ::= { pm1001lhrCntLine 152 } pm1001lhrCntdfrmB1ErrCntEntry OBJECT-TYPE SYNTAX Pm1001lhrCntdfrmB1ErrCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCntdfrmB1ErrCnt table " INDEX { pm1001lhrCntdfrmB1ErrCntIndex } ::= { pm1001lhrCntdfrmB1ErrCntTable 1 } Pm1001lhrCntdfrmB1ErrCntEntry ::= SEQUENCE { pm1001lhrCntdfrmB1ErrCntIndex INTEGER, pm1001lhrCntdfrmB1ErrCntValuePortn Counter32, pm1001lhrCntdfrmB1ErrCntErrorPortn EkiOnOff, pm1001lhrCntdfrmB1ErrCntOverloadPortn EkiOnOff } pm1001lhrCntdfrmB1ErrCntIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCntdfrmB1ErrCnt table " ::= { pm1001lhrCntdfrmB1ErrCntEntry 1 } pm1001lhrCntdfrmB1ErrCntValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Input SM-BIP8 Errors :This counter is incremented each time a B1 error is detected on the Deframer input stream. This counter gives the number of B1 errors on the line port " ::= { pm1001lhrCntdfrmB1ErrCntEntry 2 } pm1001lhrCntdfrmB1ErrCntErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port " ::= { pm1001lhrCntdfrmB1ErrCntEntry 3 } pm1001lhrCntdfrmB1ErrCntOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a B1 error counter overload on Port " ::= { pm1001lhrCntdfrmB1ErrCntEntry 4 } --- ********************************************************* --- TABLE for the pm1001lhrCntdfrmTimCnt articles --- ********************************************************* pm1001lhrCntdfrmTimCntTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCntdfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCntdfrmTimCnt Article " ::= { pm1001lhrCntLine 153 } pm1001lhrCntdfrmTimCntEntry OBJECT-TYPE SYNTAX Pm1001lhrCntdfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCntdfrmTimCnt table " INDEX { pm1001lhrCntdfrmTimCntIndex } ::= { pm1001lhrCntdfrmTimCntTable 1 } Pm1001lhrCntdfrmTimCntEntry ::= SEQUENCE { pm1001lhrCntdfrmTimCntIndex INTEGER, pm1001lhrCntdfrmTimCntValuePortn Counter32, pm1001lhrCntdfrmTimCntErrorPortn EkiOnOff, pm1001lhrCntdfrmTimCntOverloadPortn EkiOnOff } pm1001lhrCntdfrmTimCntIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCntdfrmTimCnt table " ::= { pm1001lhrCntdfrmTimCntEntry 1 } pm1001lhrCntdfrmTimCntValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Timer Counter :This is the timing counter dedicated to the downstream deframer counters. It is incremented every 125 us. " ::= { pm1001lhrCntdfrmTimCntEntry 2 } pm1001lhrCntdfrmTimCntErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port " ::= { pm1001lhrCntdfrmTimCntEntry 3 } pm1001lhrCntdfrmTimCntOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port " ::= { pm1001lhrCntdfrmTimCntEntry 4 } --- ********************************************************* --- TABLE for the pm1001lhrCntdfrmPrimLineErrCnt articles --- ********************************************************* pm1001lhrCntdfrmPrimLineErrCntTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCntdfrmPrimLineErrCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrCntdfrmPrimLineErrCnt Article " ::= { pm1001lhrCntLine 154 } pm1001lhrCntdfrmPrimLineErrCntEntry OBJECT-TYPE SYNTAX Pm1001lhrCntdfrmPrimLineErrCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrCntdfrmPrimLineErrCnt table " INDEX { pm1001lhrCntdfrmPrimLineErrCntIndex } ::= { pm1001lhrCntdfrmPrimLineErrCntTable 1 } Pm1001lhrCntdfrmPrimLineErrCntEntry ::= SEQUENCE { pm1001lhrCntdfrmPrimLineErrCntIndex INTEGER, pm1001lhrCntdfrmPrimLineErrCntValuePortn Counter32, pm1001lhrCntdfrmPrimLineErrCntErrorPortn EkiOnOff, pm1001lhrCntdfrmPrimLineErrCntOverloadPortn EkiOnOff } pm1001lhrCntdfrmPrimLineErrCntIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrCntdfrmPrimLineErrCnt table " ::= { pm1001lhrCntdfrmPrimLineErrCntEntry 1 } pm1001lhrCntdfrmPrimLineErrCntValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Input FEC Corrected Errors :This counter is incremented each time the FEC is correcting an error on the line input stream. This counter gives the number of errors corrected by the FEC on the line port " ::= { pm1001lhrCntdfrmPrimLineErrCntEntry 2 } pm1001lhrCntdfrmPrimLineErrCntErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line " ::= { pm1001lhrCntdfrmPrimLineErrCntEntry 3 } pm1001lhrCntdfrmPrimLineErrCntOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line " ::= { pm1001lhrCntdfrmPrimLineErrCntEntry 4 } pm1001lhrCntCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters Reset:This OID resets and restarts all the counters" ::= { pm1001lhrcounters 259 } pm1001lhrCntCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters stop:This OID stops all the counters" ::= { pm1001lhrcounters 260 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pm1001lhrMesrsynth0 OBJECT-TYPE SYNTAX EkiMeasureType MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Not Used :This OID gives the unit used on AUX1 measurement of XFP#1 (Unit = ) " ::= { pm1001lhrMesrOther 0 } pm1001lhrMesrsynth1 OBJECT-TYPE SYNTAX EkiMeasureType MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Not Used :This OID gives the unit used on AUX2 measurement of XFP#1 (Unit = ) " ::= { pm1001lhrMesrOther 1 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LxModTempMeas articles --- ********************************************************* pm1001lhrMesrxfp1LxModTempMeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxModTempMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrxfp1LxModTempMeas Article " ::= { pm1001lhrMesrLine 208 } pm1001lhrMesrxfp1LxModTempMeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LxModTempMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LxModTempMeas table " INDEX { pm1001lhrMesrxfp1LxModTempMeasIndex } ::= { pm1001lhrMesrxfp1LxModTempMeasTable 1 } Pm1001lhrMesrxfp1LxModTempMeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LxModTempMeasIndex INTEGER, pm1001lhrMesrxfp1LxModTempMeasPortn INTEGER } pm1001lhrMesrxfp1LxModTempMeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LxModTempMeas table " ::= { pm1001lhrMesrxfp1LxModTempMeasEntry 1 } pm1001lhrMesrxfp1LxModTempMeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Temperature :This OID gives the temperature of the XFP or OTX plugged in line#n, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the temperature of the line transceiver " ::= { pm1001lhrMesrxfp1LxModTempMeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1Reserved articles --- ********************************************************* pm1001lhrMesrxfp1ReservedTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1ReservedEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " List of pm1001lhrMesrxfp1Reserved Article " ::= { pm1001lhrMesrLine 209 } pm1001lhrMesrxfp1ReservedEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1ReservedEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " Row definition for the pm1001lhrMesrxfp1Reserved table " INDEX { pm1001lhrMesrxfp1ReservedIndex } ::= { pm1001lhrMesrxfp1ReservedTable 1 } Pm1001lhrMesrxfp1ReservedEntry ::= SEQUENCE { pm1001lhrMesrxfp1ReservedIndex INTEGER, pm1001lhrMesrxfp1ReservedPortn INTEGER } pm1001lhrMesrxfp1ReservedIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Index definition for the pm1001lhrMesrxfp1Reserved table " ::= { pm1001lhrMesrxfp1ReservedEntry 1 } pm1001lhrMesrxfp1ReservedPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Not Used :Reserved " ::= { pm1001lhrMesrxfp1ReservedEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LoBiasCurrentMeas articles --- ********************************************************* pm1001lhrMesrxfp1LoBiasCurrentMeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrxfp1LoBiasCurrentMeas Article " ::= { pm1001lhrMesrLine 210 } pm1001lhrMesrxfp1LoBiasCurrentMeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas table " INDEX { pm1001lhrMesrxfp1LoBiasCurrentMeasIndex } ::= { pm1001lhrMesrxfp1LoBiasCurrentMeasTable 1 } Pm1001lhrMesrxfp1LoBiasCurrentMeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LoBiasCurrentMeasIndex INTEGER, pm1001lhrMesrxfp1LoBiasCurrentMeasPortn INTEGER } pm1001lhrMesrxfp1LoBiasCurrentMeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LoBiasCurrentMeas table " ::= { pm1001lhrMesrxfp1LoBiasCurrentMeasEntry 1 } pm1001lhrMesrxfp1LoBiasCurrentMeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Laser Bias :This OID gives the bias value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This measure gives the bias of the line transceiver " ::= { pm1001lhrMesrxfp1LoBiasCurrentMeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LoTxPowerMeas articles --- ********************************************************* pm1001lhrMesrxfp1LoTxPowerMeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LoTxPowerMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrxfp1LoTxPowerMeas Article " ::= { pm1001lhrMesrLine 211 } pm1001lhrMesrxfp1LoTxPowerMeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LoTxPowerMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LoTxPowerMeas table " INDEX { pm1001lhrMesrxfp1LoTxPowerMeasIndex } ::= { pm1001lhrMesrxfp1LoTxPowerMeasTable 1 } Pm1001lhrMesrxfp1LoTxPowerMeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LoTxPowerMeasIndex INTEGER, pm1001lhrMesrxfp1LoTxPowerMeasPortn INTEGER } pm1001lhrMesrxfp1LoTxPowerMeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LoTxPowerMeas table " ::= { pm1001lhrMesrxfp1LoTxPowerMeasEntry 1 } pm1001lhrMesrxfp1LoTxPowerMeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Tx Power :This OID gives the transmit power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Tx optical power of the line transceiver " ::= { pm1001lhrMesrxfp1LoTxPowerMeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LiRxPowerMeas articles --- ********************************************************* pm1001lhrMesrxfp1LiRxPowerMeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LiRxPowerMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrxfp1LiRxPowerMeas Article " ::= { pm1001lhrMesrLine 212 } pm1001lhrMesrxfp1LiRxPowerMeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LiRxPowerMeasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LiRxPowerMeas table " INDEX { pm1001lhrMesrxfp1LiRxPowerMeasIndex } ::= { pm1001lhrMesrxfp1LiRxPowerMeasTable 1 } Pm1001lhrMesrxfp1LiRxPowerMeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LiRxPowerMeasIndex INTEGER, pm1001lhrMesrxfp1LiRxPowerMeasPortn INTEGER } pm1001lhrMesrxfp1LiRxPowerMeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LiRxPowerMeas table " ::= { pm1001lhrMesrxfp1LiRxPowerMeasEntry 1 } pm1001lhrMesrxfp1LiRxPowerMeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Rx Power :This OID gives the receive power value of the XFP or OTX plugged in line #n, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Rx optical power of the line transceiver " ::= { pm1001lhrMesrxfp1LiRxPowerMeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LxAux1Meas articles --- ********************************************************* pm1001lhrMesrxfp1LxAux1MeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxAux1MeasEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " List of pm1001lhrMesrxfp1LxAux1Meas Article " ::= { pm1001lhrMesrLine 213 } pm1001lhrMesrxfp1LxAux1MeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LxAux1MeasEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LxAux1Meas table " INDEX { pm1001lhrMesrxfp1LxAux1MeasIndex } ::= { pm1001lhrMesrxfp1LxAux1MeasTable 1 } Pm1001lhrMesrxfp1LxAux1MeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LxAux1MeasIndex INTEGER, pm1001lhrMesrxfp1LxAux1MeasPortn INTEGER } pm1001lhrMesrxfp1LxAux1MeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LxAux1Meas table " ::= { pm1001lhrMesrxfp1LxAux1MeasEntry 1 } pm1001lhrMesrxfp1LxAux1MeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) " ::= { pm1001lhrMesrxfp1LxAux1MeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrxfp1LxAux2Meas articles --- ********************************************************* pm1001lhrMesrxfp1LxAux2MeasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrxfp1LxAux2MeasEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " List of pm1001lhrMesrxfp1LxAux2Meas Article " ::= { pm1001lhrMesrLine 214 } pm1001lhrMesrxfp1LxAux2MeasEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrxfp1LxAux2MeasEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " Row definition for the pm1001lhrMesrxfp1LxAux2Meas table " INDEX { pm1001lhrMesrxfp1LxAux2MeasIndex } ::= { pm1001lhrMesrxfp1LxAux2MeasTable 1 } Pm1001lhrMesrxfp1LxAux2MeasEntry ::= SEQUENCE { pm1001lhrMesrxfp1LxAux2MeasIndex INTEGER, pm1001lhrMesrxfp1LxAux2MeasPortn INTEGER } pm1001lhrMesrxfp1LxAux2MeasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Index definition for the pm1001lhrMesrxfp1LxAux2Meas table " ::= { pm1001lhrMesrxfp1LxAux2MeasEntry 1 } pm1001lhrMesrxfp1LxAux2MeasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Not Used :This OID gives the receive power value read in the DDM (Digital Diagnostic Monitoring) of the XFP or OTX plugged in line #n (Unit = ?) " ::= { pm1001lhrMesrxfp1LxAux2MeasEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrotx1Aging articles --- ********************************************************* pm1001lhrMesrotx1AgingTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrotx1AgingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrotx1Aging Article " ::= { pm1001lhrMesrLine 224 } pm1001lhrMesrotx1AgingEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrotx1AgingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrotx1Aging table " INDEX { pm1001lhrMesrotx1AgingIndex } ::= { pm1001lhrMesrotx1AgingTable 1 } Pm1001lhrMesrotx1AgingEntry ::= SEQUENCE { pm1001lhrMesrotx1AgingIndex INTEGER, pm1001lhrMesrotx1AgingPortn INTEGER } pm1001lhrMesrotx1AgingIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrotx1Aging table " ::= { pm1001lhrMesrotx1AgingEntry 1 } pm1001lhrMesrotx1AgingPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line OTX TLH Aging :This OID gives the aging of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) This measure gives the aging of the Line OTX TLH " ::= { pm1001lhrMesrotx1AgingEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrotx1LaserTemperature articles --- ********************************************************* pm1001lhrMesrotx1LaserTemperatureTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrotx1LaserTemperatureEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " List of pm1001lhrMesrotx1LaserTemperature Article " ::= { pm1001lhrMesrLine 225 } pm1001lhrMesrotx1LaserTemperatureEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrotx1LaserTemperatureEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION " Row definition for the pm1001lhrMesrotx1LaserTemperature table " INDEX { pm1001lhrMesrotx1LaserTemperatureIndex } ::= { pm1001lhrMesrotx1LaserTemperatureTable 1 } Pm1001lhrMesrotx1LaserTemperatureEntry ::= SEQUENCE { pm1001lhrMesrotx1LaserTemperatureIndex INTEGER, pm1001lhrMesrotx1LaserTemperaturePortn INTEGER } pm1001lhrMesrotx1LaserTemperatureIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Index definition for the pm1001lhrMesrotx1LaserTemperature table " ::= { pm1001lhrMesrotx1LaserTemperatureEntry 1 } pm1001lhrMesrotx1LaserTemperaturePortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS deprecated DESCRIPTION " Line OTX TLH Laser Temperature :This OID gives the laser temperature of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the laser temperature of the Line OTX TLH " ::= { pm1001lhrMesrotx1LaserTemperatureEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrotx1FreqDeviation articles --- ********************************************************* pm1001lhrMesrotx1FreqDeviationTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrotx1FreqDeviationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrotx1FreqDeviation Article " ::= { pm1001lhrMesrLine 226 } pm1001lhrMesrotx1FreqDeviationEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrotx1FreqDeviationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrotx1FreqDeviation table " INDEX { pm1001lhrMesrotx1FreqDeviationIndex } ::= { pm1001lhrMesrotx1FreqDeviationTable 1 } Pm1001lhrMesrotx1FreqDeviationEntry ::= SEQUENCE { pm1001lhrMesrotx1FreqDeviationIndex INTEGER, pm1001lhrMesrotx1FreqDeviationPortn INTEGER } pm1001lhrMesrotx1FreqDeviationIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrotx1FreqDeviation table " ::= { pm1001lhrMesrotx1FreqDeviationEntry 1 } pm1001lhrMesrotx1FreqDeviationPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (AV-32768)*100) (Unit = MHz) This measure gives the frequency deviation of the Line OTX TLH " ::= { pm1001lhrMesrotx1FreqDeviationEntry 2 } --- ********************************************************* --- TABLE for the pm1001lhrMesrotx1LaserWvlength articles --- ********************************************************* pm1001lhrMesrotx1LaserWvlengthTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrMesrotx1LaserWvlengthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pm1001lhrMesrotx1LaserWvlength Article " ::= { pm1001lhrMesrLine 227 } pm1001lhrMesrotx1LaserWvlengthEntry OBJECT-TYPE SYNTAX Pm1001lhrMesrotx1LaserWvlengthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pm1001lhrMesrotx1LaserWvlength table " INDEX { pm1001lhrMesrotx1LaserWvlengthIndex } ::= { pm1001lhrMesrotx1LaserWvlengthTable 1 } Pm1001lhrMesrotx1LaserWvlengthEntry ::= SEQUENCE { pm1001lhrMesrotx1LaserWvlengthIndex INTEGER, pm1001lhrMesrotx1LaserWvlengthPortn INTEGER } pm1001lhrMesrotx1LaserWvlengthIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pm1001lhrMesrotx1LaserWvlength table " ::= { pm1001lhrMesrotx1LaserWvlengthEntry 1 } pm1001lhrMesrotx1LaserWvlengthPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Wavelength :This OID gives the laser wavelength of the Line OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=299792458/((193,100+(AV-32768 )*12,5)*10 3)) (Unit = nm) This measure gives the laser wavelength of the Line OTX TLH " ::= { pm1001lhrMesrotx1LaserWvlengthEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- DOWNLOAD --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the restartProcess article --- ***************************************************** pm1001lhrDwlrestartProcess OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 0 } pm1001lhrDwlColdRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Cold Restart :This OID indicates that the module last restart was a Cold RESTART " ::= { pm1001lhrDwlrestartProcess 2 } pm1001lhrDwlWarmRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warm Restart :This OID indicates that the module last restart was a Warm RESTART " ::= { pm1001lhrDwlrestartProcess 1 } --- ***************************************************** --- LEAF for the swBanksUsed article --- ***************************************************** pm1001lhrDwlswBanksUsed OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 1 } pm1001lhrDwlSwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 This status indicates if the SW bank 2 contains SW package " ::= { pm1001lhrDwlswBanksUsed 6 } pm1001lhrDwlSwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 This status indicates if the SW bank 1 contains SW package " ::= { pm1001lhrDwlswBanksUsed 5 } pm1001lhrDwlSwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 active :This OID indicates the module is working on SW bank 2 This status indicates if the SW bank 2 is active or standby " ::= { pm1001lhrDwlswBanksUsed 2 } pm1001lhrDwlSwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 active :This OID indicates the module is working on SW bank 1 This status indicates if the SW bank 1 is active or standby " ::= { pm1001lhrDwlswBanksUsed 1 } --- ***************************************************** --- LEAF for the gwBanksUsed article --- ***************************************************** pm1001lhrDwlgwBanksUsed OBJECT IDENTIFIER ::= { pm1001lhrDwlOther 2 } pm1001lhrDwlGwBank4Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 " ::= { pm1001lhrDwlgwBanksUsed 8 } pm1001lhrDwlGwBank3Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 This status indicates if the GW bank 3 contains GW package " ::= { pm1001lhrDwlgwBanksUsed 7 } pm1001lhrDwlGwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 " ::= { pm1001lhrDwlgwBanksUsed 6 } pm1001lhrDwlGwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 This status indicates if the GW bank 1 contains GW package " ::= { pm1001lhrDwlgwBanksUsed 5 } pm1001lhrDwlGwBank4Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 active :This OID indicates the module is working on GW bank 4 " ::= { pm1001lhrDwlgwBanksUsed 4 } pm1001lhrDwlGwBank3Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 active :This OID indicates the module is working on GW bank 3 This status indicates if the GW bank 3 is active or standby " ::= { pm1001lhrDwlgwBanksUsed 3 } pm1001lhrDwlGwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 active :This OID indicates the module is working on GW bank 2 " ::= { pm1001lhrDwlgwBanksUsed 2 } pm1001lhrDwlGwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 active :This OID indicates the module is working on GW bank 1 This status indicates if the GW bank 1 is active or standby " ::= { pm1001lhrDwlgwBanksUsed 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group accessCAisCsf --- ***************************************************** pm1001lhrCfgAccessCAisCsf OBJECT IDENTIFIER ::= { pm1001lhrConfig 1 } --- ***************************************************** --- LEAF for the table Group startup --- ***************************************************** pm1001lhrCfgStartup OBJECT IDENTIFIER ::= { pm1001lhrConfig 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pm1001lhrtablelineStartup OBJECT IDENTIFIER ::= { pm1001lhrCfgStartup 1 } pm1001lhrCfgsystConfLine1 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 1 :This register configures the default initialisation settings on Line port 1. " ::= { pm1001lhrtablelineStartup 2 } pm1001lhrCfgnetConfMod OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Protocol on Module :This register configures the default initialisation protocol on the module. " ::= { pm1001lhrtablelineStartup 3 } pm1001lhrCfglineOptions1 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Active Line Port :This register configures the default options on the active line port " ::= { pm1001lhrtablelineStartup 5 } pm1001lhrCfgsystConfLine2 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 2 :This register configures the default initialisation settings on Line port 2. " ::= { pm1001lhrtablelineStartup 6 } pm1001lhrCfglineOptions2 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Active Line Port :This register configures the default options on the active line port " ::= { pm1001lhrtablelineStartup 9 } --- ***************************************************** --- LEAF for the table 21AB --- ***************************************************** pm1001lhrCfgXfpTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCfgXfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001lhrCfgStartup 2 } pm1001lhrCfgXfpEntry OBJECT-TYPE SYNTAX Pm1001lhrCfgXfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pm1001lhrCfgXfpIndex } ::= { pm1001lhrCfgXfpTable 1 } Pm1001lhrCfgXfpEntry ::= SEQUENCE { pm1001lhrCfgXfpIndex INTEGER, pm1001lhrCfgSystConfXfpPortn Unsigned32, pm1001lhrCfgDataRateConfXfpPortn Unsigned32 } pm1001lhrCfgXfpIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the xfp table " ::= { pm1001lhrCfgXfpEntry 1 } pm1001lhrCfgSystConfXfpPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on XFP Port :This register configures the default initialisation settings on XFP port. " ::= { pm1001lhrCfgXfpEntry 3 } pm1001lhrCfgDataRateConfXfpPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " : " ::= { pm1001lhrCfgXfpEntry 4 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pm1001lhrCfgLabels OBJECT IDENTIFIER ::= { pm1001lhrConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pm1001lhrCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001lhrCfgLabels 1 } pm1001lhrCfgLabelclientEntry OBJECT-TYPE SYNTAX Pm1001lhrCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pm1001lhrCfgLabelclientIndex } ::= { pm1001lhrCfgLabelclientTable 1 } Pm1001lhrCfgLabelclientEntry ::= SEQUENCE { pm1001lhrCfgLabelclientIndex INTEGER, pm1001lhrCfgLabelclientPortn DisplayString } pm1001lhrCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pm1001lhrCfgLabelclientEntry 1 } pm1001lhrCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pm1001lhrCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pm1001lhrCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001lhrCfgLabels 2 } pm1001lhrCfgLabellineEntry OBJECT-TYPE SYNTAX Pm1001lhrCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pm1001lhrCfgLabellineIndex } ::= { pm1001lhrCfgLabellineTable 1 } Pm1001lhrCfgLabellineEntry ::= SEQUENCE { pm1001lhrCfgLabellineIndex INTEGER, pm1001lhrCfgLabellinePortn DisplayString } pm1001lhrCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pm1001lhrCfgLabellineEntry 1 } pm1001lhrCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pm1001lhrCfgLabellineEntry 3 } --- ***************************************************** --- LEAF for the table Group startuptlh --- ***************************************************** pm1001lhrCfgStartuptlh OBJECT IDENTIFIER ::= { pm1001lhrConfig 4 } --- ***************************************************** --- LEAF for the table 25A8 --- ***************************************************** pm1001lhrCfgOtxtlhTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001lhrCfgStartuptlh 1 } pm1001lhrCfgOtxtlhEntry OBJECT-TYPE SYNTAX Pm1001lhrCfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startuptlh table " INDEX { pm1001lhrCfgOtxtlhIndex } ::= { pm1001lhrCfgOtxtlhTable 1 } Pm1001lhrCfgOtxtlhEntry ::= SEQUENCE { pm1001lhrCfgOtxtlhIndex INTEGER, pm1001lhrCfgNuPortn Unsigned32, pm1001lhrCfgLineDitherRatePortn Unsigned32, pm1001lhrCfgLineDitherFhzPortn Unsigned32, pm1001lhrCfgLinePwrLaserPortn Unsigned32, pm1001lhrCfgLineFCurrentPortn Unsigned32, pm1001lhrCfgLineGridCurrentPortn Unsigned32, pm1001lhrCfgFPortn Unsigned32, pm1001lhrCfgReservedPortn Unsigned32, pm1001lhrCfgLinePhotodiodeModePortn Unsigned32, pm1001lhrCfgLinePhotodiodeValuePortn Unsigned32 } pm1001lhrCfgOtxtlhIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlh table " ::= { pm1001lhrCfgOtxtlhEntry 1 } pm1001lhrCfgNuPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " : " ::= { pm1001lhrCfgOtxtlhEntry 3 } pm1001lhrCfgLineDitherRatePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 4 } pm1001lhrCfgLineDitherFhzPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 5 } pm1001lhrCfgLinePwrLaserPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Defaut Line OTX TLH output Power :This register configures the start-up output power of the Line OTX TLH (Unit = dBm) " ::= { pm1001lhrCfgOtxtlhEntry 6 } pm1001lhrCfgLineFCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH Channel :This register configures the start-up laser channel of the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 7 } pm1001lhrCfgLineGridCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH Grid :This register configures the start-up laser grid of the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 8 } pm1001lhrCfgFPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 9 } pm1001lhrCfgReservedPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " : " ::= { pm1001lhrCfgOtxtlhEntry 10 } pm1001lhrCfgLinePhotodiodeModePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH APD mode :This register configures the start-up APD mode of the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 11 } pm1001lhrCfgLinePhotodiodeValuePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line OTX TLH APD atten. :This register configures the start-up APD attenuation on the Line OTX TLH " ::= { pm1001lhrCfgOtxtlhEntry 12 } --- ***************************************************** --- LEAF for the table Group startuptablefive --- ***************************************************** pm1001lhrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm1001lhrConfig 5 } --- ***************************************************** --- LEAF for the table 0005 --- ***************************************************** pm1001lhrCfgOtxtlhcapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001lhrCfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001lhrCfgStartuptablefive 1 } pm1001lhrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE SYNTAX Pm1001lhrCfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startuptablefive table " INDEX { pm1001lhrCfgOtxtlhcapabilitiesIndex } ::= { pm1001lhrCfgOtxtlhcapabilitiesTable 1 } Pm1001lhrCfgOtxtlhcapabilitiesEntry ::= SEQUENCE { pm1001lhrCfgOtxtlhcapabilitiesIndex INTEGER, pm1001lhrCfgComponentTypePortn Unsigned32, pm1001lhrCfgMiscellaneousPortn Unsigned32, pm1001lhrCfgFirstChannelPortn Unsigned32, pm1001lhrCfgLastChannelPortn Unsigned32, pm1001lhrCfgGridPortn Unsigned32 } pm1001lhrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlhcapabilities table " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 1 } pm1001lhrCfgComponentTypePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Component parameters :This OID defines the component parameters " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 3 } pm1001lhrCfgMiscellaneousPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Miscellaneous default settings :This OID defines the miscellaneous parameters " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 4 } pm1001lhrCfgFirstChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the first channel of the component :This OID defines the first channel number of the PM " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 5 } pm1001lhrCfgLastChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the last channel of the component :This OID defines the last channel number of the PM " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 6 } pm1001lhrCfgGridPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Grid value of the component :This OID defines the grid of the PM " ::= { pm1001lhrCfgOtxtlhcapabilitiesEntry 7 } pm1001lhrCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pm1001lhrConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pm1001lhrtrapLineNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last Line which generates a trap" ::= { pm1001lhrtraps 3 } pm1001lhrtrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pm1001lhrtraps 4 } --- ***************************************************** --- LINE TRAPS --- ***************************************************** pm1001lhrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineDdmWarningPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pm1001lhrAlmLineDdmWarningPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"} --&MESG "DDM Warning appears on Line Port $2 of PM1001LHR in Slot $3 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pm1001lhrtraps 30 } pm1001lhrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineDdmWarningPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001LHR Line Not Urgent ON" } --&MATCH { pm1001lhrAlmLineDdmWarningPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"} --&MESG "DDM Warning disappears on Line Port $2 of PM1001LHR in Slot $3 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pm1001lhrtraps 31 } pm1001lhrLineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineDdmAlmPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pm1001lhrAlmLineDdmAlmPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"} --&MESG "DDM Alarm appears on Line Port $2 of PM1001LHR in Slot $3 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pm1001lhrtraps 32 } pm1001lhrLineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineDdmAlmPortn, pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001LHR Line Urgent ON" } --&MATCH { pm1001lhrAlmLineDdmAlmPortn "on", pm1001lhrtrapLineNumber "$2", pm1001lhrtrapBoardNumber "$3"} --&MESG "DDM Alarm disappears on Line Port $2 of PM1001LHR in Slot $3 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pm1001lhrtraps 33 } pm1001lhrLineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineFailPortn , pm1001lhrAlmLineHwFailPortn , pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pm1001lhrAlmLineFailPortn "on", pm1001lhrAlmLineHwFailPortn "*", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"} --&MESG "Line Port $3 Down on PM1001LHR in Slot $4 ($A)" --&FILTNAME "PM1001LHR Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pm1001lhrAlmLineFailPortn "*", pm1001lhrAlmLineHwFailPortn "on", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"} --&MESG "Line Port $3 Down on PM1001LHR in Slot $4 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pm1001lhrtraps 34 } pm1001lhrLineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmLineFailPortn , pm1001lhrAlmLineHwFailPortn , pm1001lhrtrapLineNumber, pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001LHR Line Fail ON" } --&MATCH { pm1001lhrAlmLineFailPortn "on", pm1001lhrAlmLineHwFailPortn "*", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"} --&MESG "Line Port $3 Up on PM1001LHR in Slot $4 ($A)" --&FILTNAME "PM1001LHR Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pm1001lhrAlmLineFailPortn "*", pm1001lhrAlmLineHwFailPortn "on", pm1001lhrtrapLineNumber "$3", pm1001lhrtrapBoardNumber "$4"} --&MESG "Line Port $3 Up on PM1001LHR in Slot $4 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pm1001lhrtraps 35 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pm1001lhrPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmDefFuseB, pm1001lhrAlmDefFuseA , pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pm1001lhrAlmDefFuseB "*", pm1001lhrAlmDefFuseA "on", pm1001lhrtrapBoardNumber "$3"} --&MESG "Power Input A Fail on PM1001LHR in Slot $3 ($A)" --&FILTNAME "PM1001LHR Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pm1001lhrAlmDefFuseB "on", pm1001lhrAlmDefFuseA "*", pm1001lhrtrapBoardNumber "$3"} --&MESG "Power Input B Fail on PM1001LHR in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pm1001lhrtraps 50 } pm1001lhrPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001lhrAlmDefFuseB, pm1001lhrAlmDefFuseA , pm1001lhrtrapBoardNumber} STATUS current --&FILTNAME "PM1001LHR Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PM1001LHR Fuse A Fail ON", "PM1001LHR Fuse B Fail ON" } --&MATCH { pm1001lhrAlmDefFuseB "on", pm1001lhrAlmDefFuseA "on", pm1001lhrtrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PM1001LHR in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pm1001lhrtraps 51 } END