SDEVICE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP FROM SNMPv2-CONF Integer32, IpAddress, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY, OBJECT-TYPE, enterprises FROM SNMPv2-SMI DisplayString, MacAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC ; -- example usage: -- -- snmpwalk -c public -m SDEVICE-MIB 192.168.1.200 inputmeasuresTable schleifenbauer MODULE-IDENTITY LAST-UPDATED "201504131700Z" -- April 13th, 2015 ORGANIZATION "Schleifenbauer Engineering" CONTACT-INFO "Schleifenbauer Engineering Alain Schuermans Chief Technology Officer Turnhoutseweg 22 5541 NX Reusel The Netherlands t. +31 73 5230256 f. +31 73 5212383 alain@schleifenbauer.eu www.schleifenbauer.eu" DESCRIPTION "This MIB describes the functions of the Schleifenbauer device family." ::= { enterprises 31034 } ConfigurationEntry ::= SEQUENCE { channelIndex2 Integer32, noPhases Integer32, noOutletsTotal Integer32, noSwitchedOutlets Integer32, noMeasuredOutlets Integer32, maximumLoad Integer32, noTempSensors Integer32, noEnvSensors Integer32 } DeciAmps ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Data type for reporting measurements and thresholds associated with current sensors. If the underlying hardware sensor indicates 1.1 amp, then the SNMP agent will report a value of 11 DeciAmps. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support." SYNTAX Integer32 DeciCelsius ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Data type for reporting sensor readings associated with temperature sensors. If the underlying hardware sensor indicates 20.1 degree Celsius, then the SNMP agent will report a value of 201 tenth degrees Celsius. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support." SYNTAX Integer32 DeciPowerFactor ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Data type for reporting measurements associated with power factor calculation. The power factor of an AC power system is defined as the ratio of the real or active power to the apparent power and is a number between 0 and 1. A DeciPowerFactor value is calculated by taking this ratio and multiplying by 1000. A power factor of 98.3% will be reported as 983. The power factor is used to indicate how efficiently a particular load is utilizing energy." SYNTAX Integer32 -- Textual Conventions DeciValue ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Data type for reporting generic measurements associated with environmental sensors. If the underlying hardware sensor indicates 21.1 degree, then the SNMP agent will report a value of 211 DeciValue. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support." SYNTAX Integer32 DeciVolts ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-2" STATUS current DESCRIPTION "Data type for reporting measurements and thresholds associated with voltage sensors. If the underlying hardware sensor indicates 231.1 volts, then the SNMP agent will report a value of 2311 DeciVolts. The value is scaled in this manner as a way to deal with floating point types that SNMP does not currently support." SYNTAX Integer32 IdentificationEntry ::= SEQUENCE { channelIndex1 Integer32, spdmVersion Integer32, firmwareVersion Integer32, salesOrderNumber DisplayString, productId DisplayString, serialNumber DisplayString, hardwareAddress DisplayString, unitAddress Integer32, busPosition Integer32 } KiloWattHour ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "Data type for reporting measurements associated with energy accumulation sensors. If the underlying hardware sensor indicates 1 kWh, then the SNMP agent will report a value of 1 kWh. No scaling is performed for this type." SYNTAX Integer32 MilliSeconds ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The unit of duration for some settings" SYNTAX Integer32 Seconds ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "The unit of duration for some settings" SYNTAX Integer32 SystemstatusEntry ::= SEQUENCE { channelIndex3 Integer32, deviceStatusCode Integer32, temperatureAlert Integer32, inputCurrentAlert Integer32, outputCurrentAlert Integer32, inputVoltageAlert Integer32, oCurrentDropAlert Integer32, iCurrentDropAlert Integer32 } device0 OBJECT IDENTIFIER ::= { schleifenbauer 2 } identification OBJECT IDENTIFIER ::= { device0 3 } spdmVersion OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-only STATUS current DESCRIPTION "Data model version, currently 1.10" ::= { identification 1 } firmwareVersion OBJECT-TYPE SYNTAX Integer32 (0..9999) MAX-ACCESS read-only STATUS current DESCRIPTION "The units firmware revision number." ::= { identification 2 } buildNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time of latest build of the firmware." ::= { identification 3 } salesOrderNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SP sales order number." ::= { identification 4 } productId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SP product id." ::= { identification 5 } serialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SP serial number." ::= { identification 6 } hardwareAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware serial number; cannot be changed. Can be used as backup unit address. format as 3 unsigned ints separated by dashes: int - int - int" ::= { identification 7 } macAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The ethernet interfaces unique hardware address." ::= { identification 8 } unitAddress OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "User defined address; this will be used for addressing the unit." ::= { identification 9 } deviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User configurable device name or identifier." ::= { identification 10 } deviceLocation OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User configurable device location identifier." ::= { identification 11 } vanityTag OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Characters to be displayed as vanity tekst in display." ::= { identification 12 } configuration OBJECT IDENTIFIER ::= { device0 4 } noPhases OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Either zero, one or three for no input metering, single or three phase system" ::= { configuration 1 } noOutletsTotal OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of outlets, even hardwired without switch/measure modules." ::= { configuration 2 } noSwitchedOutlets OBJECT-TYPE SYNTAX Integer32 (0..48) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of switched outlets. If outlet numbering is non-contiguous: the highest outlet number." ::= { configuration 3 } noMeasuredOutlets OBJECT-TYPE SYNTAX Integer32 (0..48) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of measured outlets. If outlet numbering is non-contiguous: the highest outlet number." ::= { configuration 4 } noSensors OBJECT-TYPE SYNTAX Integer32 (0..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of external, digital environmental sensors: 0 for none, 1 to 16 depending on number of reported sensors" ::= { configuration 5 } maximumLoad OBJECT-TYPE SYNTAX Integer32 (0..32) MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum rated load of device per phase, usually either 16 or 32 A." ::= { configuration 6 } systemstatus OBJECT IDENTIFIER ::= { device0 5 } deviceStatusCode OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns an internal status or error code. 0 = OK, 16 = watchdog timer caused reset, 128 = slave module was reset, 144 = both previous." ::= { systemstatus 1 } temperatureAlert OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to temperature exceeding treshhold; 0= no alert; 1= internal unit temp, 2= external sensor." ::= { systemstatus 2 } inputCurrentAlert OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to current exceeding treshhold; 0=no alert; 1-3 for input phase." ::= { systemstatus 3 } outputCurrentAlert OBJECT-TYPE SYNTAX Integer32 (0..48) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to current exceeding treshhold; 0=no alert; 1-48 for outlet." ::= { systemstatus 4 } inputVoltageAlert OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to a voltage dip; 0=no alert; 1-3 for input phase." ::= { systemstatus 5 } oCurrentDropAlert OBJECT-TYPE SYNTAX Integer32 (0..103) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to the current of a measured outlet suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-48 for outlet." ::= { systemstatus 6 } iCurrentDropAlert OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "An alert has been raised due to the current of a measured input suddenly dropping to near zero, possibly indicating a blown fuse; 0=no alert; 1-3 for phase." ::= { systemstatus 7 } reset OBJECT IDENTIFIER ::= { device0 6 } rebootDevice OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Warm reboot/reset of device; note: this will have no effect on outlet status!" ::= { reset 1 } resetAlerts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reset all alert signals." ::= { reset 2 } zeroInputKWhSubtotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reset of input kWh subtotal counters to zero." ::= { reset 3 } zeroOutKWhSubtotal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reset of outlet kWh subtotal counter to zero." ::= { reset 4 } resetPeakValues OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reset all peak values to zero, as well input as output metering, voltages dips, current peaks and temperatures." ::= { reset 5 } settings OBJECT IDENTIFIER ::= { device0 7 } general OBJECT IDENTIFIER ::= { settings 1 } peakDuration OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-write STATUS current DESCRIPTION "A current peak should last at least [stpkdr] MilliSeconds before an alert is raised; max about a minute." ::= { general 4 } fixedOutletDelay OBJECT-TYPE SYNTAX MilliSeconds MAX-ACCESS read-write STATUS current DESCRIPTION "Minimal delay between two successive relay switches in milliseconds. Minimal delay is 100 ms. Will always be respected!" ::= { general 5 } powerSaverMode OBJECT-TYPE SYNTAX Seconds MAX-ACCESS read-write STATUS current DESCRIPTION "Set backlight on time in seconds; 0 keeps display always on. Note that keeping the backlight on may decrease luminosity over time. Setting this to other values than 10, 60, 120 or 240 is incompatible with the gateway!" ::= { general 6 } outletPowerupMode OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "Behaviour of outlet on power-up: 0=off; 1=same state as at power down; 2=same state, but delayed by individual delay timer." ::= { general 7 } maximumTemperature OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "An alert should be generated whenever the temperature of the first connected T sensor is above this value. Zero means disabled." ::= { general 8 } displayOrientation OBJECT-TYPE SYNTAX Integer32 (0..4) MAX-ACCESS read-write STATUS current DESCRIPTION "0 no display; display off; 1 vertical, display on top; 2 vertical, upside down; 3 horizontal, display at left; 4 horizontal, display at right" ::= { general 9 } localAlertReset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Allow alerts to be reset locally on device by pushing one of the buttons. [replaces dipDuration]" ::= { general 10 } currentDropDetection OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the current drop detection function. 0 = always off (default), 1 = input (s) only, 2 = output(s) only, 3 = both inputs and outputs." ::= { general 11 } wirelessDisplayPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Controls the transit power of the wireless display transciever (if installed). Set to zero to completely disable the module." ::= { general 12 } -- number of channels depends on noPhases inputmeasuresTable OBJECT-TYPE SYNTAX SEQUENCE OF InputmeasuresEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all measures related to the measured inputs of the DEVICE. Note: either 1 or 3 channels, depending on number of phases measured." ::= { device0 8 } inputmeasuresEntry OBJECT-TYPE SYNTAX InputmeasuresEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The record containing the registers for the channel selected by channelIndex." INDEX { channelIndex6 } ::= { inputmeasuresTable 1 } InputmeasuresEntry ::= SEQUENCE { channelIndex6 Integer32, kWhTotalI KiloWattHour, kWhSubtotalI KiloWattHour, powerFactorI DeciPowerFactor, actualCurrentI DeciAmps, peakCurrentI DeciAmps, actualVoltageI DeciVolts, minVoltageI DeciVolts, powerVAI Integer32, powerWattI Integer32, maxInletAmps DeciAmps, inputCTratio Integer32, inputName DisplayString } channelIndex6 OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1." ::= { inputmeasuresEntry 1 } kWhTotalI OBJECT-TYPE SYNTAX KiloWattHour MAX-ACCESS read-only STATUS current DESCRIPTION "Either the only phase in a single phase measurement; or one of the three phases in a multiphase measurement." ::= { inputmeasuresEntry 2 } kWhSubtotalI OBJECT-TYPE SYNTAX KiloWattHour MAX-ACCESS read-only STATUS current DESCRIPTION "kWh subtotal register of the only phase in a single phase measurement; or one of three phases in a multiphase measurement. Reset to zero with [rsimks]." ::= { inputmeasuresEntry 3 } powerFactorI OBJECT-TYPE SYNTAX DeciPowerFactor MAX-ACCESS read-only STATUS current DESCRIPTION "The effective power factor in percent." ::= { inputmeasuresEntry 4 } actualCurrentI OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-only STATUS current DESCRIPTION "Actual apparent, RMS current." ::= { inputmeasuresEntry 5 } peakCurrentI OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-only STATUS current DESCRIPTION "Peak apparent, RMS current; highest value since last reset of the alerts." ::= { inputmeasuresEntry 6 } actualVoltageI OBJECT-TYPE SYNTAX DeciVolts MAX-ACCESS read-only STATUS current DESCRIPTION "The actual voltage." ::= { inputmeasuresEntry 7 } minVoltageI OBJECT-TYPE SYNTAX DeciVolts MAX-ACCESS read-only STATUS current DESCRIPTION "RMS voltage dip; lowest value since reset of alerts." ::= { inputmeasuresEntry 8 } powerVAI OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Power value calculated, not in data model of device." ::= { inputmeasuresEntry 9 } powerWattI OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Power value calculated by the gateway, not in data model of device." ::= { inputmeasuresEntry 10 } maxInletAmps OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum current per input phase in A; should last at least [stpkdr] MilliSeconds before triggering an alert." ::= { inputmeasuresEntry 11 } inputCTratio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The multiplier to use in case of use of /5 current transformers. Defaults to 1." ::= { inputmeasuresEntry 12 } inputName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User configurable naming of inputs or phases. Useful if channels are used to measure branches.." ::= { inputmeasuresEntry 13 } -- number of channels depends on noOutletsTotal outletsTable OBJECT-TYPE SYNTAX SEQUENCE OF OutletsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the customer specific settings, determining toutlestablehe behaviour of the DEVICE." ::= { device0 9 } outletsEntry OBJECT-TYPE SYNTAX OutletsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The record containing the registers forthe channel selected by channelIndex." INDEX { channelIndex4 } ::= { outletsTable 1 } OutletsEntry ::= SEQUENCE { channelIndex4 Integer32, outletName DisplayString } channelIndex4 OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1." ::= { outletsEntry 1 } outletName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "User configurable naming of individual outlets. Useful to distinguish outlets based on customer or device name." ::= { outletsEntry 2 } -- number of channels depends on noMeasuredOutlets outputmeasuresTable OBJECT-TYPE SYNTAX SEQUENCE OF OutputmeasuresEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all measures related to the measured outputs of the DEVICE. Note: up to 48 channels, depending on number of measured outlets." ::= { device0 10 } outputmeasuresEntry OBJECT-TYPE SYNTAX OutputmeasuresEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The record containing the registers for the channel selected by channelIndex." INDEX { channelIndex7 } ::= { outputmeasuresTable 1 } OutputmeasuresEntry ::= SEQUENCE { channelIndex7 Integer32, kWhTotalO KiloWattHour, kWhSubtotalO KiloWattHour, powerFactorO DeciPowerFactor, actualCurrentO DeciAmps, peakCurrentO DeciAmps, actualVoltageO DeciVolts, maxOutletAmps DeciAmps, outputCTratio Integer32 } channelIndex7 OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1." ::= { outputmeasuresEntry 1 } kWhTotalO OBJECT-TYPE SYNTAX KiloWattHour MAX-ACCESS read-only STATUS current DESCRIPTION "Total kWh of selected output." ::= { outputmeasuresEntry 2 } kWhSubtotalO OBJECT-TYPE SYNTAX KiloWattHour MAX-ACCESS read-only STATUS current DESCRIPTION "kWh subtotal register of selected output. Reset to zero with [rsomks]." ::= { outputmeasuresEntry 3 } powerFactorO OBJECT-TYPE SYNTAX DeciPowerFactor MAX-ACCESS read-only STATUS current DESCRIPTION "Power factor of output." ::= { outputmeasuresEntry 4 } actualCurrentO OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-only STATUS current DESCRIPTION "Actual apparent, RMS current." ::= { outputmeasuresEntry 5 } peakCurrentO OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-only STATUS current DESCRIPTION "Peak apparent, RMS current; highest value since last reset of alerts." ::= { outputmeasuresEntry 6 } actualVoltageO OBJECT-TYPE SYNTAX DeciVolts MAX-ACCESS read-only STATUS current DESCRIPTION "Actual voltage on output." ::= { outputmeasuresEntry 7 } maxOutletAmps OBJECT-TYPE SYNTAX DeciAmps MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum current per outlet in A; should last at least [stpkdr] MilliSeconds before triggering an alert." ::= { outputmeasuresEntry 8 } outputCTratio OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The multiplier to use in case of use of /5 current transformers. Defaults to 1." ::= { outputmeasuresEntry 9 } -- number of channels depends on noSwitchedOutlets switchedoutletsTable OBJECT-TYPE SYNTAX SEQUENCE OF SwitchedoutletsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the current status of switchable DEVICE's." ::= { device0 11 } switchedoutletsEntry OBJECT-TYPE SYNTAX SwitchedoutletsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The record containing the registers for the channel selected by channelIndex." INDEX { channelIndex5 } ::= { switchedoutletsTable 1 } SwitchedoutletsEntry ::= SEQUENCE { channelIndex5 Integer32, currentState Integer32, scheduled Integer32, unlock Integer32, individualOutletDelay Seconds } channelIndex5 OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1." ::= { switchedoutletsEntry 1 } currentState OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-write STATUS current DESCRIPTION "The actual state of the outlet relays. The hardware will contain max 48 outlets. Writing is only effective after setting [swounl]." ::= { switchedoutletsEntry 2 } scheduled OBJECT-TYPE SYNTAX Integer32 (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "A one indicates pending activity; the switch delay has not yet expired." ::= { switchedoutletsEntry 3 } unlock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value to one will release the safety for this outlet for a couple seconds; switching and rebooting are then temporarily enabled." ::= { switchedoutletsEntry 4 } individualOutletDelay OBJECT-TYPE SYNTAX Seconds MAX-ACCESS read-write STATUS current DESCRIPTION "Delay before an individual outlet switches on at power-up in Seconds." ::= { switchedoutletsEntry 5 } -- number of channels depends on noEnvSensors sensorTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the environmental measurements. As well internal temperature as external temperature probes." ::= { device0 12 } sensorEntry OBJECT-TYPE SYNTAX SensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The record containing the registers for the channel selected by channelIndex." INDEX { channelIndex8 } ::= { sensorTable 1 } SensorEntry ::= SEQUENCE { channelIndex8 Integer32, sensorType DisplayString, sensorValue DeciValue, sensorName DisplayString } channelIndex8 OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The channel. Its value ranges between 1 and 48, depending on the number of channels, usually 1." ::= { sensorEntry 1 } sensorType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Type of connected sensor, either T, H or I for respectively Temperature (C), Humidity (%) or dry switch contact" ::= { sensorEntry 2 } sensorValue OBJECT-TYPE SYNTAX DeciValue MAX-ACCESS read-only STATUS current DESCRIPTION "Value of connected sensor" ::= { sensorEntry 3 } sensorName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "User definable name for sensors." ::= { sensorEntry 4 } conformance OBJECT IDENTIFIER ::= { schleifenbauer 99 } -- conformance information compliances OBJECT IDENTIFIER ::= { conformance 1 } -- compliance statements compliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The requirements for conformance to the SPGW-MIB." MODULE SDEVICE-MIB GROUP sensorsGroup DESCRIPTION "The sensors group." GROUP outputMeasuresGroup DESCRIPTION "The outputMeasures group." GROUP inputMeasuresGroup DESCRIPTION "The inputMeasures group." GROUP switchedOutletsGroup DESCRIPTION "The switchedOutlets group." GROUP settingsGroup DESCRIPTION "The settings group." GROUP systemStatusGroup DESCRIPTION "The systemStatus group." GROUP configurationGroup DESCRIPTION "The configuration group." GROUP identificationGroup DESCRIPTION "The identification group." GROUP resetGroup DESCRIPTION "resettable attributes in device" ::= { compliances 1 } groups OBJECT IDENTIFIER ::= { conformance 2 } -- units of conformance note: volatile, not part of spdm identificationGroup OBJECT-GROUP OBJECTS { spdmVersion, firmwareVersion, salesOrderNumber, productId, serialNumber, hardwareAddress, unitAddress, deviceName, deviceLocation, vanityTag, macAddress, buildNumber } STATUS current DESCRIPTION "A collection of objects providing identification information about the device." ::= { groups 1 } configurationGroup OBJECT-GROUP OBJECTS { noPhases, noOutletsTotal, noSwitchedOutlets, noMeasuredOutlets, maximumLoad, noSensors } STATUS current DESCRIPTION "A collection of objects providing configuration information about the device." ::= { groups 2 } systemStatusGroup OBJECT-GROUP OBJECTS { deviceStatusCode, temperatureAlert, inputCurrentAlert, outputCurrentAlert, inputVoltageAlert, oCurrentDropAlert, iCurrentDropAlert } STATUS current DESCRIPTION "A collection of objects providing status information about the device." ::= { groups 3 } resetGroup OBJECT-GROUP OBJECTS { resetAlerts, resetPeakValues, rebootDevice, zeroInputKWhSubtotal, zeroOutKWhSubtotal } STATUS current DESCRIPTION "Groups resettable attributes op the device." ::= { groups 4 } settingsGroup OBJECT-GROUP OBJECTS { peakDuration, localAlertReset, fixedOutletDelay, powerSaverMode, outletPowerupMode, maximumTemperature, displayOrientation, maxInletAmps, maxOutletAmps, outputCTratio, inputCTratio, inputName, outletName, individualOutletDelay, currentDropDetection, wirelessDisplayPower } STATUS current DESCRIPTION "A collection of objects providing the actual settings about the device." ::= { groups 5 } switchedOutletsGroup OBJECT-GROUP OBJECTS { currentState, scheduled, individualOutletDelay, unlock } STATUS current DESCRIPTION "A collection of objects providing the actual outlet status of the device." ::= { groups 6 } inputMeasuresGroup OBJECT-GROUP OBJECTS { kWhTotalI, kWhSubtotalI, powerFactorI, actualCurrentI, peakCurrentI, actualVoltageI, minVoltageI, powerWattI, powerVAI, maxInletAmps, inputCTratio, inputName } STATUS current DESCRIPTION "A collection of objects providing the actual input measurements of the device." ::= { groups 7 } outputMeasuresGroup OBJECT-GROUP OBJECTS { kWhTotalO, kWhSubtotalO, powerFactorO, actualCurrentO, peakCurrentO, actualVoltageO, maxOutletAmps, outputCTratio } STATUS current DESCRIPTION "A collection of objects providing the actual output measurements of the device." ::= { groups 8 } sensorsGroup OBJECT-GROUP OBJECTS { sensorType, sensorValue, sensorName } STATUS current DESCRIPTION "A collection of objects providing the actual environmental measurements of the device." ::= { groups 9 } END