RAD-PM-MIB DEFINITIONS ::= BEGIN -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS ifIndex FROM IF-MIB Counter32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Counter64 FROM SNMPv2-SMI RowStatus, DateAndTime FROM SNMPv2-TC sysName FROM SNMPv2-MIB alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, AlarmEventSourceType FROM RAD-GEN-MIB agnt FROM RAD-SMI-MIB; agnPerformanceManagement MODULE-IDENTITY LAST-UPDATED "201607071624Z" -- July 07, 2016 ORGANIZATION "RAD Data Communications Ltd." CONTACT-INFO "System Department Email: mibs@rad.com Postal: RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel-Aviv 6971920 Israel Phone: +972-3-645-5421 Fax: +972-3-760-7844" DESCRIPTION "PM MIB." ::= { agnt 74 } pmEvents OBJECT IDENTIFIER ::= {agnPerformanceManagement 0 } -- RAD Performance Management pmNumberOfIntervals OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This counter holds the number of error-measurement periods (Intervals) since the network management portion of the system was last re-initialized." ::= { agnPerformanceManagement 1 } --***************************************** -- PM Enabling per entity that has ifIdex. --***************************************** pmEntitiesEnableTable OBJECT-TYPE SYNTAX SEQUENCE OF PmEntityEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table define enabling of PM of all entitites that have ifIndex format definition. The table contains also logical entites that have ifIndex definition, but are not included in the ifTable e.g. flow, ETP or PW." ::= { agnPerformanceManagement 2 } pmEntityEnableEntry OBJECT-TYPE SYNTAX PmEntityEnableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry defines one entity code." INDEX { ifIndex } -- INDEX { pmEntityEnableIndex } ::= { pmEntitiesEnableTable 1} PmEntityEnableEntry ::= SEQUENCE { pmEntityActivity INTEGER } pmEntityActivity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The entity PM activity state." ::= { pmEntityEnableEntry 1 } -- pmEntityEnableIndex OBJECT-TYPE -- SYNTAX Unsigned32 (1..4294967295) -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "Unique value identification of entity or interface." -- ::= { pmEntityEnableEntry 2 } pmIntervalTimeDuration OBJECT-TYPE SYNTAX Unsigned32 ( 300 | 600 | 900 ) MAX-ACCESS read-write STATUS current DESCRIPTION "System level definition of duration of all non-TDM performance monitoring Intervals (in seconds). Note - even objects marked in MIB as PerfIntervalCount SYNTAX will be affected." DEFVAL {900} ::= { agnPerformanceManagement 3 } systemPmStatusCmdTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemPmStatusCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table that holds a set of Scalar as columns." ::= { agnPerformanceManagement 4 } systemPmStatusCmdEntry OBJECT-TYPE SYNTAX SystemPmStatusCmdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." INDEX { systemPmStatusCmdIndex } ::= { systemPmStatusCmdTable 1 } SystemPmStatusCmdEntry ::= SEQUENCE { systemPmStatusCmdIndex Unsigned32, systemPmStatusCmdActivation INTEGER, systemPmStatusCmdStopReason INTEGER, systemPmStatusCmdFreeSpace Unsigned32 } systemPmStatusCmdIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object used as index value = 1" ::= { systemPmStatusCmdEntry 1 } systemPmStatusCmdActivation OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This command is related to systemPmIntervalConfigTable and it defines the collection activation at the device level. on - a command to activate the Performance Interval data collection process. off - agent will inactivate the Performance Interval data collection process. " ::= { systemPmStatusCmdEntry 2 } systemPmStatusCmdStopReason OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), spaceOverflow(2), timeDeltaOverfow(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the reason failure of collection process. This object is sent as a varbind trap. spaceOverflow(2)- space overflow, the agent cannot store the PM file. timeDeltaOverfow(3)- PM file not retrieved for too long time." ::= { systemPmStatusCmdEntry 3} systemPmStatusCmdFreeSpace OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The PM file free space in bytes" ::= { systemPmStatusCmdEntry 4 } -- system Pm Interval Config Table systemPmIntervalConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemPmIntervalConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entity level PM interval configuration Table." ::= { agnPerformanceManagement 5 } systemPmIntervalConfigEntry OBJECT-TYPE SYNTAX SystemPmIntervalConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table." INDEX { systemPmIntervalConfigIfIndexType , systemPmIntervalConfigIfIndex } ::= { systemPmIntervalConfigTable 1 } SystemPmIntervalConfigEntry ::= SEQUENCE { systemPmIntervalConfigIfIndexType AlarmEventSourceType, systemPmIntervalConfigIfIndex Unsigned32, systemPmIntervalConfigRowStatus RowStatus, systemPmIntervalConfigInterval Unsigned32 } systemPmIntervalConfigIfIndexType OBJECT-TYPE SYNTAX AlarmEventSourceType MAX-ACCESS not-accessible STATUS current DESCRIPTION "The type of the entity of which PM statistics are collected. The current supported types are: abm (20600) eth (50000) flow (210000) oamCfmDestNe (270400) oamCfmService (270300) system (20000) twamp (300900)" ::= { systemPmIntervalConfigEntry 1 } systemPmIntervalConfigIfIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entity of which PM statistics are collected. Typically, the indices are the same ones used as alarm/event source ID. -- For ABM the index is the same as the corresponding abmConfigSessionIndex. -- If the device (e.g. MiNID) supports PM collection from all entities, the special value of 0xffffffff is used, along with systemPmIntervalConfigIfIndexType of system." ::= { systemPmIntervalConfigEntry 2 } systemPmIntervalConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to create/delete entries in this table." ::= { systemPmIntervalConfigEntry 3 } systemPmIntervalConfigInterval OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The duration of the interval - hundredths of seconds. The range is from 1 to 900 seconds" ::= { systemPmIntervalConfigEntry 4 } ----------------------------------- -- Rate Measurements ----------------------------------- pmPortRateStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF PmPortRateStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for measuring the rates of ports and LAGs. A row can be deleted unconditionally." ::= { agnPerformanceManagement 7 } pmPortRateStatsEntry OBJECT-TYPE SYNTAX PmPortRateStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in Port Rate statistics table." INDEX {ifIndex} ::= { pmPortRateStatsTable 1 } PmPortRateStatsEntry ::= SEQUENCE { pmPortRateStatsRowStatus RowStatus, pmPortRateStatsMeasureCmd INTEGER, pmPortRateStatsDuration Unsigned32, pmPortRateStatsStartTime DateAndTime, pmPortRateStatsStatus INTEGER, pmPortRateStatsRxBytes Counter64, pmPortRateStatsTxBytes Counter64 } pmPortRateStatsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to create/delete entries in this table. " ::= { pmPortRateStatsEntry 1} pmPortRateStatsMeasureCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Issue a command for beginning the measurement of the Port/LAG Rate. Upon setting the command, the value shall be 'on (3)'. After pmPortRateStatsDuration time elapses, the agent shall set this MIB object to 'off (2)'. Upon invocation, all counters should be reset. It is not possible to update this object while pmPortRateStatsStatus is inProgress(3). " ::= { pmPortRateStatsEntry 2} pmPortRateStatsDuration OBJECT-TYPE SYNTAX Unsigned32 (10..300) UNITS "Seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Sampling window duration in seconds. It is not possible to update this object while pmPortRateStatsStatus is inProgress(3). " DEFVAL {10} ::= { pmPortRateStatsEntry 3} pmPortRateStatsStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time of setting pmPortRateStatsMeasureCmd to on(3). " ::= { pmPortRateStatsEntry 4} pmPortRateStatsStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idle (2), inProgress (3), failed (4), passed (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the measurement: idle - Measurement is not running at present. For example, after row is created and before running the measurement. inProgress - Rate is currently being measured. failed - Measurement has failed. Examples for failure causes: Measurement aborted due to Clear Statistics invocation or shutdown of entity during measurement. passed - Rate measurement has succeeded. " ::= { pmPortRateStatsEntry 5} pmPortRateStatsRxBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes received over the interface during the sampling window. " ::= { pmPortRateStatsEntry 6} pmPortRateStatsTxBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes transmitted over the interface during the sampling window. " ::= { pmPortRateStatsEntry 7} pmFlowRateConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF PmFlowRateConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for invocation of flow rate measurements. A row can be deleted unconditionally." ::= { agnPerformanceManagement 8 } pmFlowRateConfigEntry OBJECT-TYPE SYNTAX PmFlowRateConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in Flow Rate configuration table. When a row is added, corresponding rows are automatically added to the pmFlowRateStatsTable. When a row is deleted, all the corresponding rows in the pmFlowRateStatsTable are automatically deleted as well. " INDEX {pmFlowRateConfigflowIdx1, pmFlowRateConfigflowIdx2} ::= { pmFlowRateConfigTable 1 } PmFlowRateConfigEntry ::= SEQUENCE { pmFlowRateConfigflowIdx1 Unsigned32, pmFlowRateConfigflowIdx2 Unsigned32, pmFlowRateConfigRowStatus RowStatus, pmFlowRateConfigMeasureCmd INTEGER, pmFlowRateConfigDuration Unsigned32, pmFlowRateConfigStartTime DateAndTime, pmFlowRateConfigStatus INTEGER } pmFlowRateConfigflowIdx1 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique first index of the Flow to be measured. " ::= { pmFlowRateConfigEntry 1} pmFlowRateConfigflowIdx2 OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION " A unique second index of the Flow to be measured. " ::= { pmFlowRateConfigEntry 2} pmFlowRateConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object enables user to create/delete entries in this table." ::= { pmFlowRateConfigEntry 3} pmFlowRateConfigMeasureCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Issue a command for beginning the measurement of the Flow Rate. Upon setting the command, the value shall be 'on (3)'. After pmPortRateConfigDuration time elapses, the agent shall set this MIB object to 'off (2)'. Upon invocation, all counters should be reset. It is not possible to update this object while pmFlowRateConfigStatus is inProgress(3). " ::= { pmFlowRateConfigEntry 4} pmFlowRateConfigDuration OBJECT-TYPE SYNTAX Unsigned32 (10..300) UNITS "Seconds" MAX-ACCESS read-create STATUS current DESCRIPTION "Sampling window duration in seconds. It is not possible to update this object while pmFlowRateConfigStatus is inProgress(3). " DEFVAL {10} ::= { pmFlowRateConfigEntry 5} pmFlowRateConfigStartTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The time of setting pmFlowRateConfigMeasureCmd to on(3). " ::= { pmFlowRateConfigEntry 6} pmFlowRateConfigStatus OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idle (2), inProgress (3), failed (4), passed (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the measurement: idle - Measurement is not running at present. For example, after row is created and before running the measurement. inProgress - Rate is currently being measured. failed - Measurement has failed. Examples for failure causes: Measurement aborted due to Clear Statistics invocation or shutdown of entity during measurement. passed - Rate measurement has succeeded. " ::= { pmFlowRateConfigEntry 7} pmFlowRateStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF PmFlowRateStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used for displaying the flow rate statistics. Flow rate statistics can be measured by invocation of pmFlowRateConfigMeasureCmd." ::= { agnPerformanceManagement 9 } pmFlowRateStatsEntry OBJECT-TYPE SYNTAX PmFlowRateStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry in Flow Rate statistics table. Rows in this table are created automatically when a row is added to the pmFlowRateStatsTable. Rows in this table are removed automatically when a row is removed from the pmFlowRateStatsTable. " INDEX {pmFlowRateConfigflowIdx1, pmFlowRateConfigflowIdx2, pmFlowRateStatsCosIndex} ::= { pmFlowRateStatsTable 1 } PmFlowRateStatsEntry ::= SEQUENCE { pmFlowRateStatsCosIndex Unsigned32, pmFlowRateStatsRxBytes Counter64, pmFlowRateStatsTxBytes Counter64, pmFlowRateStatsGreenDropBytes Counter64, pmFlowRateStatsYellowDropBytes Counter64, pmFlowRateStatsRedDropBytes Counter64, pmFlowRateStatsTotalDropBytes Counter64 } pmFlowRateStatsCosIndex OBJECT-TYPE SYNTAX Unsigned32 (0..7 | 255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "For Multi CoS flows, this object specifies the CoS to which the statistics in this table applies. CoS values shall be: 0..7 For Single CoS flows, the value of this Index shall be 255. " ::= { pmFlowRateStatsEntry 1} pmFlowRateStatsRxBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes received over the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 2} pmFlowRateStatsTxBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes transmitted over the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 3} pmFlowRateStatsGreenDropBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes in Green marked frames discarded from the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 4} pmFlowRateStatsYellowDropBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes in Yellow marked frames discarded from the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 5} pmFlowRateStatsRedDropBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of bytes in Red marked frames discarded from the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 6} pmFlowRateStatsTotalDropBytes OBJECT-TYPE SYNTAX Counter64 UNITS "bytes" MAX-ACCESS read-only STATUS current DESCRIPTION "The Total number of bytes discarded from the flow during the sampling window. For Multi CoS flow, MEF 10.3, this object is per CoS. " ::= { pmFlowRateStatsEntry 7} ----------------------------------- -- PM Common Trap Definitions ----------------------------------- systemPmProcessDisabled NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, sysName, systemPmStatusCmdStopReason } STATUS current DESCRIPTION "PM collection failure trap." ::= { pmEvents 1 } systemPmSpaceOverflow NOTIFICATION-TYPE OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason, sysName, systemPmStatusCmdFreeSpace } STATUS current DESCRIPTION "PM collection space over flow trap." ::= { pmEvents 2 } END