DKSF-561-1-X-X-1 DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, Counter32, NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC sysName FROM SNMPv2-MIB ; netPingIOv3 MODULE-IDENTITY LAST-UPDATED "202110070000Z" ORGANIZATION "Alentis Electronics" CONTACT-INFO "developers@netping.ru" DESCRIPTION "MIB for NetPing IO v3 (254R301) remote sensing and control" REVISION "202110070000Z" DESCRIPTION "npIoLineN fixed, range must be 1..4; npPwrChannelN fixed, range must be 1..2" REVISION "202011060000Z" DESCRIPTION "Initial release" ::= { lightcom 561 } lightcom OBJECT IDENTIFIER::={enterprises 25728 } npPwr OBJECT IDENTIFIER::={ lightcom 5800 } npPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF NpPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Watchdog and outlet/relay control table" ::= { npPwr 3 } npPwrEntry OBJECT-TYPE SYNTAX NpPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Watchdog control table row" INDEX { npPwrChannelN } ::= { npPwrTable 1 } NpPwrEntry ::= SEQUENCE { npPwrChannelN INTEGER, npPwrStartReset INTEGER, npPwrResetsCounter INTEGER, npPwrRepeatingResetsCounter INTEGER, npPwrMemo DisplayString } npPwrChannelN OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The id of watchdog/power channel" ::= { npPwrEntry 1 } npPwrStartReset OBJECT-TYPE SYNTAX INTEGER (0..2) MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Deprecated in current FW version: Write 1 to start forced reset. On read: 0 - normal operation 1 - reset is active 2 - reboot pause is active or watchdog is inactive" ::={npPwrEntry 2} npPwrResetsCounter OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Counter of watchdog resets Write 0 to clear." ::={npPwrEntry 4} npPwrRepeatingResetsCounter OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Counter of continous failed watchdog resets" ::={npPwrEntry 5} npPwrMemo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Watchdog channel memo" ::={npPwrEntry 6} npPwrWdogTrapData OBJECT IDENTIFIER::={ npPwr 2 } npPwrWdogTrapN OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "No of Watchdog channel / output relay" ::= { npPwrWdogTrapData 1 } npPwrWdogTrapMemo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Watchdog/Relay memo" ::={npPwrWdogTrapData 6} npPwrWdogTrapFailBitmap OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Failed adresses, bit 0 - A, bit 1 - B, bit 2 - C" ::= { npPwrWdogTrapData 13 } npPwrWdogTrap OBJECT IDENTIFIER::={npPwr 6} npPwrWdogTrapReset NOTIFICATION-TYPE OBJECTS { npPwrWdogTrapN, npPwrWdogTrapMemo, npPwrWdogTrapFailBitmap } STATUS current DESCRIPTION "Watchdog reset started" ::= { npPwrWdogTrap 100 } npPwrWdogTrapSuspended NOTIFICATION-TYPE OBJECTS { npPwrWdogTrapN, npPwrWdogTrapMemo } STATUS current DESCRIPTION "Watchdog resets suspended because of no effect" ::= { npPwrWdogTrap 101 } npPwrWdogTrapResumed NOTIFICATION-TYPE OBJECTS { npPwrWdogTrapN, npPwrWdogTrapMemo } STATUS current DESCRIPTION "Watchdog normal operation resumed, successful ping after resets was suspended" ::= { npPwrWdogTrap 102 } npIo OBJECT IDENTIFIER::={lightcom 8900} npIoTable OBJECT-TYPE SYNTAX SEQUENCE OF NpIoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Digital Input/output Table" ::= { npIo 1 } npIoEntry OBJECT-TYPE SYNTAX NpIoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Digital Input/output Table Row" INDEX { npIoLineN } ::= { npIoTable 1 } NpIoEntry ::= SEQUENCE { npIoLineN INTEGER, npIoLevelIn INTEGER, npIoLevelOut INTEGER, npIoMemo DisplayString, npIoPulseCounter Counter32, npIoSinglePulseDuration INTEGER, npIoSinglePulseStart INTEGER } npIoLineN OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of IO line, from 1 to max supported" ::= { npIoEntry 1 } npIoLevelIn OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Input level, 0 or 1" ::= { npIoEntry 2 } npIoLevelOut OBJECT-TYPE SYNTAX INTEGER { flip(-1), low(0), high(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Output level, 0 or 1. Write -1 to flip output." ::= { npIoEntry 3 } npIoMemo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "IO line memo" ::= { npIoEntry 6 } npIoPulseCounter OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-write STATUS current DESCRIPTION "Pulse Counter on IO input line (counts positive fronts) Write 0 to reset." ::= { npIoEntry 9 } npIoSinglePulseDuration OBJECT-TYPE SYNTAX INTEGER (100..25500) MAX-ACCESS read-write STATUS current DESCRIPTION "Set duration of single pulse on IO output line, 100ms to 25500ms, min. step is 100ms" ::= { npIoEntry 12 } npIoSinglePulseStart OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Write 1 to start single pulse on IO output. Output will be inverted for time, specified by npIoSinglePulseDuration" ::= { npIoEntry 13 } npIoTraps OBJECT IDENTIFIER::={npIo 2} npIoTrapPrefix OBJECT IDENTIFIER::={npIoTraps 0} npIoTrapLineN OBJECT-TYPE SYNTAX INTEGER (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Trap data, Number of IO line" ::= { npIoTraps 1 } npIoTrapLevelIn OBJECT-TYPE SYNTAX INTEGER (0..1) MAX-ACCESS read-only STATUS current DESCRIPTION "Trap data, new Input level, 0 or 1" ::= { npIoTraps 2 } npIoTrapMemo OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Trap data, IO line memo" ::= { npIoTraps 6 } npIoTrapLevelLegend OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Legend for current logic level on the IO line" ::= { npIoTraps 7 } npIoTrap NOTIFICATION-TYPE OBJECTS { npIoTrapLineN, npIoTrapLevelIn, npIoTrapMemo, npIoTrapLevelLegend } STATUS current DESCRIPTION "Input state of IO line is changed" ::= { npIoTrapPrefix 1 } npReboot OBJECT IDENTIFIER::={ lightcom 911 } npSoftReboot OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Write 1 to reboot device after current operations completition" ::= { npReboot 1 } npResetStack OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Write 1 to re-initialize network stack" ::= { npReboot 2 } npForcedReboot OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Write 1 to immediate forced reboot" ::= { npReboot 3 } END