-- -- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347 -- Wednesday, March 02, 2016 at 22:48:04 -- -- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347 -- Saturday, February 27, 2016 at 15:04:41 -- -- ISM-HUAWEI-MIB.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 347 -- Thursday, March 27, 2014 at 11:36:30 -- ISM-HUAWEI-OID-BASED-TRAP-MIB DEFINITIONS ::= BEGIN IMPORTS hwinfoFaultNotificationType, hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmAdditionInfo, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmLocationAlarmID, isoConformance, basicCompliance FROM ISM-HUAWEI-MIB NOTIFICATION-GROUP FROM SNMPv2-CONF MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; -- 1.3.6.1.4.1.2011.2.91.10.2.1.15 -- March 06, 2013 at 10:10 GMT -- September 17, 2008 at 16:29 GMT -- 1.3.6.1.4.1.2011.2.91.10.2.1.1 oidBasedTrap MODULE-IDENTITY LAST-UPDATED "201303061010Z" -- March 06, 2013 at 10:10 GMT ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com" DESCRIPTION "Description." REVISION "200809171629Z" -- September 17, 2008 at 16:29 GMT DESCRIPTION "V1R1 V1R2" ::= { hwinfoFaultNotificationType 1 } -- -- Node definitions -- -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15 storage OBJECT IDENTIFIER ::= { oidBasedTrap 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6 port OBJECT IDENTIFIER ::= { storage 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.9 ethFCoEPortIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "ETH/FCoE Port Link Down." ::= { port 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.17 portIsWorkingInHalfDuplexMode NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Network Port Is Working In Half-Duplex Mode." ::= { port 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.20 expPortHasTooManyBitErrors NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Port Has Too Many Bit Errors." ::= { port 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.21 hostPortHasTooManyBitErrors NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Host Port Has Too Many Bit Errors." ::= { port 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.22 pciePortIsPartiallyDamaged NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "PCIe Port Partially Damaged." ::= { port 22 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.25 pciePortIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "PCIe Port Disconnected." ::= { port 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.6 expansionPortPartiallyDamaged NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Port Partially Damaged." ::= { port 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.2 expansionPortIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Port Link Down." ::= { port 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.29 rateIsSmallerThanAllowedMaximum NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Port Negotiated Rate Is Smaller Than The Allowed Maximum." ::= { port 29 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.15 portNegotiatedRateNotToMaximum NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Negotiated Rate Of A Port Is Smaller Than The Allowed Maximum." ::= { port 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.4 hostPortIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Host Port Link Down." ::= { port 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.73 manageNetworkPortIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Management Network Port Is Disconnected." ::= { port 73 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.16 expansionPortIsolated NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Port Isolated." ::= { port 16 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.11 managementNetworkPortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Management Network Port Is Faulty." ::= { port 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.14 pciePortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "PCIe Port Is Faulty." ::= { port 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.13 hostPortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Host Port Is Faulty." ::= { port 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.6.12 expansionPortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Port Is Faulty." ::= { port 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10 disk OBJECT IDENTIFIER ::= { storage 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.269 numberOfDisksExceedsUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Disks Exceeds The Upper Limit." ::= { disk 269 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.259 mixtureOfSATAAndNonSATADisks NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SATA Disks And Non-SATA Disks Mixed." ::= { disk 259 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.91 diskIsIsolated NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Hard Disk Is Isolated." ::= { disk 91 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.95 slowDiskResponse NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Slow Disk Response." ::= { disk 95 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.155 authenticationOfSEDAccessFails NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Authenticate Self-Encrypting Disk Access." ::= { disk 155 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.8 cofferDiskIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Coffer Disk Is Faulty." ::= { disk 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.9 cofferDiskFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Faulty Coffer." ::= { disk 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.20 diskInEngineMonitoringFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor A Disk In The Controller Enclosure." ::= { disk 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.21 diskMonitoringFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor A Disk In A Disk Enclosure." ::= { disk 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.275 diskModelIsIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incompatible Disk Model." ::= { disk 275 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.274 diskInSingleLinkState NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Is In Single Link State." ::= { disk 274 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.273 diskIsAboutToFail NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Is About To Fail." ::= { disk 273 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.279 cofferDiskModelIsIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Coffer Disk Type Is Not Supported." ::= { disk 279 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.4 diskTemperatureExceedsUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Temperature Exceeds The Upper Limit." ::= { disk 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.79 cofferDiskInInccorrectSlot NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Coffer Disk Is Inserted Into An Incorrect Slot." ::= { disk 79 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.132 diskIsRejectedBySystem NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Disk Is Rejected By The System." ::= { disk 132 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.10 cofferDisksNotFound NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Coffer Disks Not Found." ::= { disk 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.258 authenticationOfSEDKeyFails NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Authenticate A Self-Encrypting Disk Key." ::= { disk 258 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.271 diskHardwareIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Is Faulty." ::= { disk 271 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.272 diskIsUnrecognizable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Unrecognizable Disk." ::= { disk 272 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.149 svpDiskIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Disk Is Faulty." ::= { disk 149 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.10.148 svpDiskIsNotInserted NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Disk Is Not Inserted." ::= { disk 148 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11 lun OBJECT IDENTIFIER ::= { storage 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.258 externalLunTypeChanged NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "External LUN Is Changed To Command Device." ::= { lun 258 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.268 lunStartBgrTaskFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Start Bgr Task Failed." ::= { lun 268 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.267 localArrayRegPathToHeteroFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Register Paths From The Local Storage Array To Heterogeneous Storage Array." ::= { lun 267 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.2 theLUNHasMediumError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Has A Medium Error." ::= { lun 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.81 theLUNLBAHasWarningMediumError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Has A Medium Error." ::= { lun 81 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.80 theLUNLBAHasCriticalMediumError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Has A Medium Error." ::= { lun 80 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.269 snapshotLUNIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Snapshot LUN Is Faulty." ::= { lun 269 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.101 externalLUNFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "External LUN Faulty." ::= { lun 101 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.99 externalLUNToOnlyOneController NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "External LUN Has Links To Only One Controller." ::= { lun 99 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.264 remoteLinkExceedUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of The Connected Remote Links Has Exceeded The Upper Limit ." ::= { lun 264 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.265 remoteArrayExceedUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of The Connected Remote Arrays Has Exceeded The Upper Limit." ::= { lun 265 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.82 incompatibleArrayConnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incompatible Heterogeneous Array Connected To The System." ::= { lun 82 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.270 theLUNIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Is Faulty." ::= { lun 270 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.98 iscsiLinkFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "ISCSI Link Of Heterogeneous Array Faulty." ::= { lun 98 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.97 fcLinkFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "FC Link Of Heterogeneous Array Faulty." ::= { lun 97 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.96 iscsiLinkDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "ISCSI Link Of Heterogeneous Array Disconnected." ::= { lun 96 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.93 fcLinkDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "FC Link Of Heterogeneous Array Disconnected." ::= { lun 93 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.1 theLUNIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LUN Is Faulty." ::= { lun 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.11.61 snapshotLUNIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Snapshot LUN Is Faulty." ::= { lun 61 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21 host OBJECT IDENTIFIER ::= { storage 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.25 noRedundantConnectionToHost NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Host Is Not Redundantly Connected To Storage Arrays." ::= { host 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.26 aLinkToHostIsDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Link Between A Host And Storage Array Is Down." ::= { host 26 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.21.29 ultrapathIncompatibleWithStorage NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Ultrapath Incompatible With Storage Array Software." ::= { host 29 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23 power OBJECT IDENTIFIER ::= { storage 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.25 powerModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Is Faulty." ::= { power 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.5 powerModuleInputIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Input Is Abnormal." ::= { power 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.21 powerModulesTypesDifferent NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Modules Of Different Types Are Used In A Disk Enclosure." ::= { power 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.22 diskEnclHasNoRePowerModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Disk Enclosure Does Not Have A Redundant Power Module." ::= { power 22 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.24 powerModuleIsIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Type Is Mismatched." ::= { power 24 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.23 failedToMonitorAPowerModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor A Power Module." ::= { power 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.2 powerModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Is Removed." ::= { power 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.3 powerModuleFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Is Faulty." ::= { power 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.20 powerModuleHasNoInput NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Has No Input." ::= { power 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.23.4 powerModuleTempExceedsLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Power Module Temperature Exceeds The Upper Limit." ::= { power 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27 snapshot OBJECT IDENTIFIER ::= { storage 27 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.1 snapshotStopAbnormally NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Snapshot Stops Abnormally." ::= { snapshot 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.2 snapshotUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Snapshot Unavailable." ::= { snapshot 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.27.3 failedToDisableTheSnapshot NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Disable The Snapshot." ::= { snapshot 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40 filesystem OBJECT IDENTIFIER ::= { storage 40 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.289 fsObjectIsIsolated NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "An Object In File System Is Isolated." ::= { filesystem 289 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.288 fsRemainCapacityIsInsufficient NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remaining Capacity In A File System Is Insufficient." ::= { filesystem 288 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.290 fileSystemExistMediumError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Medium Errors In The File System." ::= { filesystem 290 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.291 fileOrDirExistMediumError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Medium Errors In The File Or The Directory." ::= { filesystem 291 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.287 openedFilesNumAboutToExceedThres NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Opened Files On A Controller Is About To Exceed The Upper Limit." ::= { filesystem 287 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.282 filesNumAboutToExceedThreshold NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A File System Is About To Exceed The Upper Limit." ::= { filesystem 282 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.284 filesNumExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A File System Has Reached Or Exceeded The Upper Limit." ::= { filesystem 284 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.286 openedFilesNumExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Opened Files On A Controller Has Reached Or Exceeded The Upper Limit." ::= { filesystem 286 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.274 filesNumAboutToExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A File System Is About To Exceed The Upper Limit." ::= { filesystem 274 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.275 dirFilesNumAboutToExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A Directory Of A File System Is About To Exceed The Upper Limit." ::= { filesystem 275 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.278 filesNumReachedOrExceededLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A File System Has Reached Or Exceeded The Upper Limit." ::= { filesystem 278 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.279 dirFilesNumExceededLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files In A Directory Of A File System Has Reached Or Exceeded The Upper Limit." ::= { filesystem 279 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.280 openedFilesNumExceededLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Opened Files On A Controller Has Reached Or Exceeded The Upper Limit." ::= { filesystem 280 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.285 subFilesNumToExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files Under A Directory Of A File System Has Reached Or Exceeded The Upper Limit." ::= { filesystem 285 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.283 subFilesNumAboutToExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Files Under A Directory Of A File System Is About To Exceed The Upper Limit." ::= { filesystem 283 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.116 fileSystemMetadataIsDamaged NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "File System Metadata Corrupted." ::= { filesystem 116 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.118 fileOrDirDamagedInFs NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "File Or Directory Corrupted." ::= { filesystem 118 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.69 fileSystemIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "File System Is Faulty." ::= { filesystem 69 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.40.117 writeProtectionIsEnabledForFS NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "File System Under Write Protection." ::= { filesystem 117 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.49 event OBJECT IDENTIFIER ::= { storage 49 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.49.4 eventAmountReachUpLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Space That Stores Event Logs Is To Be Used Up." ::= { event 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201 system OBJECT IDENTIFIER ::= { storage 201 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.21 controllerWriteCacheIsDisabled NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Write Cache Is Disabled." ::= { system 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.335 dnsIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Management DNS Server Is Unavailable." ::= { system 335 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.317 ipaddrConflict NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "IP Address Conflict." ::= { system 317 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.86 onlyOneClusterLinkIsAvailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Only One Cluster Link Is Available." ::= { system 86 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.201.6 systemEnterSafeMode NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Has Entered Safe Mode." ::= { system 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202 user OBJECT IDENTIFIER ::= { storage 202 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.8 userInfoNeedReview NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Super Administrator Needs To Review User Account Information." ::= { user 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.15 passwdOfUserHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Password Of The User Has Expired." ::= { user 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.14 passwdOfUserIsAboutToExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Password Of The User Is About To Expire." ::= { user 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.17 passwdOfUserHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Password Of The User Has Expired." ::= { user 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.202.16 passwdOfUserIsAboutToExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Password Of The User Is About To Expire ." ::= { user 16 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206 enclosure OBJECT IDENTIFIER ::= { storage 206 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.49 enclosureIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Faults Occurred On An Enclosure." ::= { enclosure 49 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.46 failedToMonitorTheRearPanel NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor The Rear Panel Of The Enclosure." ::= { enclosure 46 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.43 highDensityAreMixConnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "From An Expansion Port, Disk Enclosures And High-Density Disk Enclosures Are Mix-Connected." ::= { enclosure 43 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.23 numOfEnclOnExpPortExceedsLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Number Of Disk Enclosures Connected To An Expansion Port Exceeds The System Specification." ::= { enclosure 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.4 failedToIdentifyEnclosure NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Identify A Controller Enclosure Or Disk Enclosure." ::= { enclosure 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.50 enclosureIsUnrecognizable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Identify A Controller Enclosure Or Disk Enclosure." ::= { enclosure 50 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.51 enclosureCablingIsIncorrect NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incorrect Configuration Disk Enclosure Cabling." ::= { enclosure 51 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.20 faultsOccurredOnEnclosure NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Faults Occurred On An Enclosure." ::= { enclosure 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.5 diskEnclTempExceedsUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Enclosure Temperature Exceeds The Upper Limit." ::= { enclosure 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.7 diskEnclTempIsBelowLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Engine Or Disk Enclosure Temperature Is Below The Lower Limit." ::= { enclosure 7 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.8 ctrlEnclTempExceedsUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Enclosure Temperature Exceeds The Upper Limit." ::= { enclosure 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.9 ctrlEnclTempIsFarBeyondUpLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Enclosure Temperature Is Far Beyond The Upper Limit." ::= { enclosure 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.10 diskEnclTempIsFarBeyondUpLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Enclosure Temperature Is Far Beyond The Upper Limit." ::= { enclosure 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.52 enclSpeedSmallerThanLoopSpeed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Disk Enclosure Speed Does Not Reach The Maximum Loop Speed." ::= { enclosure 52 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.15 anUnsupportedExpEnclConnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Is Connected To An Unsupported Disk Enclosure." ::= { enclosure 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.42 diskEnclosureIsSingleLink NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Enclosure Is Working In Single Link State." ::= { enclosure 42 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.206.1 failedToMonitorADiskEnclosure NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Monitor A Disk Enclosure." ::= { enclosure 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207 controller OBJECT IDENTIFIER ::= { storage 207 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.20 monitorControllerFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Monitor The Controller." ::= { controller 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.5 abnormalCommunicateBetweenCtrls NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Abnormal Communication Between Controllers." ::= { controller 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.74 controllerCannotBeMonitored NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Some Statuses Of A Controller Cannot Be Monitored." ::= { controller 74 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.54 controllerServicesAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Services Are Abnormal." ::= { controller 54 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.95 controllerIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Is Faulty." ::= { controller 95 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.108 bbuIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The BBU Module Of The Controller Is About To Expire." ::= { controller 108 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.97 ctrlAndMgtCommunicateLinkFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Communication Link Fault Among The Controller And Management Modules." ::= { controller 97 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.104 controllerIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Is Faulty." ::= { controller 104 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.105 controllerIsOffline NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Is Offline." ::= { controller 105 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.23 portIsIncorrectlyConnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incorrect Connection Between A Controller Port And A Switch Port." ::= { controller 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.6 controllerIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Is Removed." ::= { controller 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.57 theCoinBatteryIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Coin Battery Is Faulty." ::= { controller 57 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.2 ftpServiceIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The FTP Service Is Abnormal." ::= { controller 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.11 processCpuUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Process CPU Usage Is Too High." ::= { controller 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.1 sshServiceIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The SSH Service Is Abnormal." ::= { controller 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.98 bbuIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Backup Power Module Of The Controller Is About To Expire ." ::= { controller 98 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.9 ntpSynchronizationIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "NTP Time Synchronization Is Abnormal." ::= { controller 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.8 excessiveFilesExistInADirectory NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Excessive Files Exist In A Directory." ::= { controller 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.12 processMemoryUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Process Memory Usage Is Too High." ::= { controller 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.7 directoryIsOversized NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Directory Is Oversized." ::= { controller 7 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.92 openedFilesNumAboutToExceedLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Opened Files On A Controller Is About To Exceed The Upper Limit." ::= { controller 92 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.94 remainAvailableMemoryTooLow NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remaining Available Memory Is Too Low." ::= { controller 94 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.13 cpuUsageTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "CPU Usage Is Too High." ::= { controller 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.14 memoryUsageTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Memory Usage Is Too High." ::= { controller 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.100 firmwareVersionIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Firmware Version Of The Backup Power Module Of The Controller Incompatible With The Storage Array Software." ::= { controller 100 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.10 controllerNetStackIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Network Protocol Stack Of A Controller Is Abnormal." ::= { controller 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.99 bbuTempHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Temperature Of The Backup Power Module Of The Controller Exceeds The Upper Limit ." ::= { controller 99 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.93 cpuUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "CPU Usage Is Too High." ::= { controller 93 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.21 monitorControllersFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Monitor Controllers Enclosure." ::= { controller 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.207.96 memoryCapacityIsNotSupported NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incorrect Controller Memory Capacity." ::= { controller 96 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208 expandboardmodule OBJECT IDENTIFIER ::= { storage 208 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.24 expansionModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Is Faulty." ::= { expandboardmodule 24 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.23 syncExpansionFirmwareFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Synchronize The Firmware Version Of An Expansion Module." ::= { expandboardmodule 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.57 sasExpansionModuleIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Shared SAS Expansion Module Firmware Is Incompatible With Storage Array Software." ::= { expandboardmodule 57 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.41 expansionModuleIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Firmware Is Incompatible With Storage Array Software." ::= { expandboardmodule 41 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.22 expansionCableLinkError NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Is Incorrectly Cabled." ::= { expandboardmodule 22 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.1 expansionModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Is Removed." ::= { expandboardmodule 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.2 expansionModuleIsNotInserted NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Is Not Inserted." ::= { expandboardmodule 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.3 expansionModuleFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Expansion Module Is Faulty." ::= { expandboardmodule 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.208.20 abnormalCommBetweenExpModules NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Abnormal Communication Between Expansion Modules." ::= { expandboardmodule 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209 interfacemodule OBJECT IDENTIFIER ::= { storage 209 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.5 interfaceModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Is Removed." ::= { interfacemodule 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.8 interfaceModuleIsUnrecognizable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Is Unrecognizable." ::= { interfacemodule 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.10 incorrectRemovalInterfaceModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incorrect Removal Of Interface Module." ::= { interfacemodule 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.9 interfaceModuleTempExceedsLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Temperature Exceeds The Upper Limit." ::= { interfacemodule 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.30 monitorInterfaceModuleFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Cannot Be Monitored." ::= { interfacemodule 30 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.66 failedToMonitorTheInternalLink NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Monitor The Internal Link Of An Interface Module." ::= { interfacemodule 66 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.62 internalLinkofIntfModIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Internal Link Of Interface Module Is Faulty." ::= { interfacemodule 62 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.65 faultyInterfaceModuleComponent NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Faulty Interface Module Component." ::= { interfacemodule 65 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.50 managementModuleIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Management Module Firmware Is Incompatible With Storage Array Software." ::= { interfacemodule 50 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.35 communicationIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Communication Link Fault Among Management Modules." ::= { interfacemodule 35 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.40 interfaceModuleIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Firmware Is Incompatible With Storage Array Software." ::= { interfacemodule 40 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.60 managementModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Management Module Is Faulty." ::= { interfacemodule 60 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.59 managementModuleIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Management Module Is Abnormal." ::= { interfacemodule 59 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.56 pcieChannelIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "PCIe Channel Between An Interface Module And A Controller Is Abnormal." ::= { interfacemodule 56 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.19 someStatusMonitoringFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Some Statuses Of A Management Module Cannot Be Monitored." ::= { interfacemodule 19 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.61 interfaceModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Interface Module Is Faulty." ::= { interfacemodule 61 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.17 pcieChannelIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The PCIe Channel Between An Interface Module And A Controller Is Abnormal." ::= { interfacemodule 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.209.18 slotDoesNotMatchInterfaceModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Interface Module Is Not Supported Or The Interface Module Is Inserted Into An Incorrect Slot ." ::= { interfacemodule 18 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210 backuppowermodule OBJECT IDENTIFIER ::= { storage 210 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.28 bbuModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Is Faulty." ::= { backuppowermodule 28 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.29 bbuModuleLifeIsOvertime NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Reaches Its Expiration Date Or Is Aging." ::= { backuppowermodule 29 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.30 bbuModuleIsAboutToExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Is About To Expire." ::= { backuppowermodule 30 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.5 bbuModuleTempExceedsLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Temperature Exceeds The Upper Limit." ::= { backuppowermodule 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.20 failedToMonitorABBUModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Cannot Be Monitored." ::= { backuppowermodule 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.39 bbuFirmwareIncompatible NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Firmware Is Incompatible With Storage Array Software." ::= { backuppowermodule 39 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.4 bbuModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Is Removed." ::= { backuppowermodule 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.25 bbuModuleTypeDoesNotComply NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The BBU Type Does Not Comply With The System Specification." ::= { backuppowermodule 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.210.27 bbuModuleTempIsBelowLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "BBU Module Temperature Is Below The Lower Limit." ::= { backuppowermodule 27 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211 fanmodule OBJECT IDENTIFIER ::= { storage 211 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211.3 fanModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Fan Module Is Removed." ::= { fanmodule 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.211.21 fanModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Fan Module Is Faulty." ::= { fanmodule 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216 storagepool OBJECT IDENTIFIER ::= { storage 216 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.291 ckgMetadataHasFaults NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "CKG Metadata Of The Storage Pool Has Faults." ::= { storagepool 291 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.86 extentMetadataOfVolumeHasFaults NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Extent Metadata Of A Volume Has Faults." ::= { storagepool 86 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.289 usedCapacityReachAlarmThreshold NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Used Protection Capacity Reaches The Alarm Threshold." ::= { storagepool 289 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.43 availableSpaceInsufficient NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Available Space In The Storage Pool Is Insufficient." ::= { storagepool 43 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.290 smartTierUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SmartTier Unavailable." ::= { storagepool 290 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.44 availableSpaceUsedUp NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "No Available Space In The Storage Pool." ::= { storagepool 44 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.288 storagePoolCapacityShouldUseUp NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Storage Pool Capacity Is About To Be Used Up." ::= { storagepool 288 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.216.281 storagePoolCapacityNotEnough NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Storage Pool Remaining Capacity Is Insufficient." ::= { storagepool 281 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.218 smartcachepool OBJECT IDENTIFIER ::= { storage 218 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.218.2 smartCacheDiskIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Member Disk Of A SmartCache Pool Gets A Fault." ::= { smartcachepool 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.219 luncopy OBJECT IDENTIFIER ::= { storage 219 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.219.2 almCpyFullCopyFail NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Full LUN Copy Is Faulty." ::= { luncopy 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220 clone OBJECT IDENTIFIER ::= { storage 220 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220.1 almCLnPairInterrupt NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Clone Pair Is Abnormally Interrupted." ::= { clone 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.220.3 almClnPairFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Clone Pair Is Unavailable." ::= { clone 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221 consistentgroup OBJECT IDENTIFIER ::= { storage 221 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.4 remoteReplicationCGAutoSplit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Consistency Group Is Automatically Split." ::= { consistentgroup 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.2 remoteReplicationCGIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Consistency Group Is Unavailable." ::= { consistentgroup 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.221.1 remoteReplicationCGIsInterrupted NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Consistency Group Is Disconnected." ::= { consistentgroup 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224 remotedevice OBJECT IDENTIFIER ::= { storage 224 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224.20 noBackupLinkForRep NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "No Backup Links Available." ::= { remotedevice 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.224.1 repLinkDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Replication Link Is Down." ::= { remotedevice 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232 pciedataswitch OBJECT IDENTIFIER ::= { storage 232 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.24 switchFanModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Fan Module Is Faulty." ::= { pciedataswitch 24 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.1 powerSupplyOfSwitchIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Power Supply Of The Switch Is Faulty." ::= { pciedataswitch 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.26 switchPowerInputIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Input To The Switch Power Module Is Abnormal." ::= { pciedataswitch 26 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.25 switchFanModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Fan Module Is Removed." ::= { pciedataswitch 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.36 negoRateSmallerThanTheMax NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum Rate." ::= { pciedataswitch 36 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.34 switchPortOpticalModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Port Optical Module Is Faulty." ::= { pciedataswitch 34 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.43 switchFailToMonitorPowModules NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Failed To Monitor Power Modules." ::= { pciedataswitch 43 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.20 switchIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Is Faulty." ::= { pciedataswitch 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.22 switchTempExceedsLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Temperature Exceeds The Upper Limit." ::= { pciedataswitch 22 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.30 switchManageNetworkPortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Management Network Port Is Faulty." ::= { pciedataswitch 30 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.27 switchPowerModuleIsRemoved NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Power Module Is Removed." ::= { pciedataswitch 27 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.21 switchFailedToBeMonitored NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Failed To Be Monitored." ::= { pciedataswitch 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.23 switchTempIsBelowLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Temperature Is Below The Lower Limit." ::= { pciedataswitch 23 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.31 switchPortIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Port Is Faulty." ::= { pciedataswitch 31 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.38 linkToASwitchPortIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Link To A Switch Port Is Abnormal." ::= { pciedataswitch 38 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.40 dswEthPortIsDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Management Network Port Is Disconnected." ::= { pciedataswitch 40 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.39 failedToMonitorSwitchOpModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Switch Optical Module Cannot Be Monitored." ::= { pciedataswitch 39 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.232.42 switchFailToMonitorFanModules NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Switch Failed To Monitor Fan Modules." ::= { pciedataswitch 42 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234 sfpopticaltransceiver OBJECT IDENTIFIER ::= { storage 234 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.3 portOpticalModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Port Optical Module Is Faulty." ::= { sfpopticaltransceiver 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.5 opticalModuleRateIsInconsistent NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Optical Module Rate Is Inconsistent With That Of Its Port." ::= { sfpopticaltransceiver 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.24 failedToMonitorOpOrEleModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor An Optical Or Electrical Module." ::= { sfpopticaltransceiver 24 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.20 portLinkIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Abnormal Port Link." ::= { sfpopticaltransceiver 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.234.21 failedToMonitorAnOpticalModule NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Optical Module Cannot Be Monitored." ::= { sfpopticaltransceiver 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244 license OBJECT IDENTIFIER ::= { storage 244 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.1 licenseIsAboutToExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "License Is About To Expire." ::= { license 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.2 licenseHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "License Has Expired." ::= { license 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.244.6 licenseIsInvalidWithStartDate NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Invalid License." ::= { license 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.253 lunmigrationtask OBJECT IDENTIFIER ::= { storage 253 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.253.8 almSmartMigrationErr NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SmartMigration Is Faulty." ::= { lunmigrationtask 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263 replicationpair OBJECT IDENTIFIER ::= { storage 263 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.58 autoStartSynRemoteRepFails NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Failed To Synchronize Data Automatically." ::= { replicationpair 58 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.56 remoteReplicationIsInterrupted NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Is Interrupted." ::= { replicationpair 56 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.57 remoteReplicationIsInvalid NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Is Unavailable." ::= { replicationpair 57 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.5 autoStartSynRemoteRepCGFails NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Consistency Group Failed To Synchronize Data Automatically." ::= { replicationpair 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.311 remoteReplicationAutomaticSplit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Remote Replication Is Automatically Split." ::= { replicationpair 311 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.274 fsRemoteReplicationPairInvalid NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Remote Replication Is Unavailable." ::= { replicationpair 274 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.275 fsRemoteReplicationPairFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Remote Replication Is Abnormally Interrupted." ::= { replicationpair 275 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.304 fsRemoteReplicationAutoSyncFail NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Remote Replication Fails To Synchronize Data Automatically." ::= { replicationpair 304 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.22 failedRecoverRmReplication NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Recover The LUN Remote Replication Service At The Array End." ::= { replicationpair 22 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.263.21 addRemoteReplicationToCGFails NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Add Remote Replication To A Consistent Group." ::= { replicationpair 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266 diskdomain OBJECT IDENTIFIER ::= { storage 266 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.83 diskDomainEnterSecureVideoState NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Domain Entering The SecureVideo State." ::= { diskdomain 83 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.3 diskDomainIsOffline NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Domain Is Offline." ::= { diskdomain 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.2 diskDomainFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Domain Is Faulty." ::= { diskdomain 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.1 diskDomainDegradation NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Disk Domain Is Degraded." ::= { diskdomain 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.84 backgroudTaskFailedToStart NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Background Task Of A Disk Domain Failed To Start." ::= { diskdomain 84 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.6 differentDiskType NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Inconsistent Disk Domain Disk Types." ::= { diskdomain 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.5 hotSpareCapacityInsufficient NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Hot Spare Capacity Of The Disk Domain Is Insufficient." ::= { diskdomain 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.8 diskIsRemovedFromDiskDomain NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Disk Is Removed From A Disk Domain." ::= { diskdomain 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.266.32 newDiskCapacityInsufficieny NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A New Disk Fails To Be Added To The Disk Domain." ::= { diskdomain 32 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268 cachepartition OBJECT IDENTIFIER ::= { storage 268 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268.11 controllerWriteCacheDisabled NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Controller Write Cache Is Disabled." ::= { cachepartition 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.268.12 cachePartitionWriteCacheDisabled NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Write Cache For A Cache Partition Is Disabled." ::= { cachepartition 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.269 qos OBJECT IDENTIFIER ::= { storage 269 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.269.67 failReachSmartQoSObjective NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Reach The Control Objective Of SmartQoS." ::= { qos 67 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.273 smartcachepartition OBJECT IDENTIFIER ::= { storage 273 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.273.1 smartcacheIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SmartCache Function Is Unavailable." ::= { smartcachepartition 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285 anti-virus OBJECT IDENTIFIER ::= { storage 285 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285.71 antivirusServiceIsNotAvailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Antivirus Service Is Not Available." ::= { anti-virus 71 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.285.68 antivirusServerIsFault NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Antivirus Server Is Fault." ::= { anti-virus 68 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293 hypervault OBJECT IDENTIFIER ::= { storage 293 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.0 hyperVaultJobCongestion NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A HyperVault Job Is Congested." ::= { hypervault 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.4 hyperVaultScheduledTaskFailure NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperVault Fails To Be Started As Scheduled." ::= { hypervault 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.13 hyperVaultCopiesReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of HyperVault Copies Reaches The Upper Limit ." ::= { hypervault 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.2 hyperVaultLinkIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Link To A Remote Device Is Down." ::= { hypervault 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.3 hyperVaultFileSystemFaults NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Owning File System Of A HyperVault Is Faulty." ::= { hypervault 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.12 hyperVaultPairInvalid NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Invalid HyperVault Pair." ::= { hypervault 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.293.14 hyperVaultInterruption NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperVault Is Interrupted ." ::= { hypervault 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306 assistantCoolingUnit OBJECT IDENTIFIER ::= { storage 306 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.4 assistCoolingUnitMonitorFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The System Failed To Monitor Assistant Cooling Unit." ::= { assistantCoolingUnit 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.1 assistantCoolingUnitNotPresent NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Assistant Cooling Unit Not Present." ::= { assistantCoolingUnit 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.306.5 coolingUnitIsUnrecognizable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Assistant Cooling Unit Is Unrecognizable." ::= { assistantCoolingUnit 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582 svp OBJECT IDENTIFIER ::= { storage 582 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.16 svpCpuUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The SVP CPU Usage Is Too High." ::= { svp 16 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.6 svpFanModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Fan Module Is Faulty." ::= { svp 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.2 svpEnclosureTemperatureIsHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Enclosure Temperature Is Too High." ::= { svp 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.1 svpCPUTemperatureIsHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP CPU Temperature Is Too High." ::= { svp 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.0 svpMainboardIsFaultyWithErrCode NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Mainboard Is Faulty." ::= { svp 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.10 svpLUNDegrades NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP LUN Degrades." ::= { svp 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.5 svpPowerModuleIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Power Module Is Faulty." ::= { svp 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.4 svpPowerModuleAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP Power Module Input Is Abnormal." ::= { svp 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.20 manageStorageEquipmentFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Manage The Storage Equipment." ::= { svp 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.11 manageSVPFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Manage The SVP." ::= { svp 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.18 svpProcessCpuUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The CPU Usage Of An SVP Process Is Too High." ::= { svp 18 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.17 svpNtpSynchronizationIsAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "SVP NTP Time Synchronization Is Abnormal." ::= { svp 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.19 svpProcessMemoryUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Memory Usage Of An SVP Process Is Too High." ::= { svp 19 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.15 svpDirectoryExcessiveFilesExist NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Excessive Files Exist In An SVP Directory." ::= { svp 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.14 svpDirectoryIsOversized NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "An SVP Directory Is Oversized." ::= { svp 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.582.13 svpMemoryUsageIsTooHigh NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The SVP Memory Usage Is Too High." ::= { svp 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583 lunmirror OBJECT IDENTIFIER ::= { storage 583 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583.16 almLunMirrorCopyErr NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Mirror Copy Is Abnormally Interrupted." ::= { lunmirror 16 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.583.17 almLunMirrorCopyUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Mirror Copy Is Unavailable." ::= { lunmirror 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.815 blockdevice OBJECT IDENTIFIER ::= { storage 815 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.815.3 blockDeviceIsFaulty NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Block Device Is Faulty." ::= { blockdevice 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818 devicemanager OBJECT IDENTIFIER ::= { storage 818 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818.2 caCertificateIsExpiring NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Of The DeviceManager Server Is Expiring." ::= { devicemanager 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.818.3 caCertificateHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Of The DeviceManager Server Has Expired." ::= { devicemanager 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822 systemreporter OBJECT IDENTIFIER ::= { storage 822 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.29 operationLogsExceedsUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Number Of Operation Logs Exceeds The Upper Limit." ::= { systemreporter 29 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.30 sshServiceUntrust NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The SSH Service Is Untrusted." ::= { systemreporter 30 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.16 majorUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Usage Exceeded The Threshold." ::= { systemreporter 16 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.8 criticalAvgCpuUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average CPU Usage Exceeded The Threshold." ::= { systemreporter 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.7 warnTimeSinceLastSyncThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Time Since Last Synchronization Exceeded The Threshold." ::= { systemreporter 7 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.11 criticalAvgIORespThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average I/O Response Time Exceeded The Threshold." ::= { systemreporter 11 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.10 criticalServiceTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Service Time Exceeded The Threshold." ::= { systemreporter 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.1 warnAvgCpuUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average CPU Usage Exceeded The Threshold." ::= { systemreporter 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.19 majorMaxIORespTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Maximum I/O Response Time Exceeded The Threshold." ::= { systemreporter 19 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.18 majorAvgIORespTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average I/O Response Time Exceeded The Threshold." ::= { systemreporter 18 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.21 majorTimeSinceSyncThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Time Since Last Synchronization Exceeded The Threshold." ::= { systemreporter 21 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.6 warnAvgCacheUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average Cache Usage Exceeded The Threshold." ::= { systemreporter 6 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.4 warnAvgIORespTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average I/O Response Time Exceeded The Threshold." ::= { systemreporter 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.15 majorAvgCpuUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average CPU Usage Exceeded The Threshold." ::= { systemreporter 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.14 criticalTimeSinceSyncThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Time Since Last Synchronization Exceeded The Threshold." ::= { systemreporter 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.9 criticalUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Usage Exceeded The Threshold." ::= { systemreporter 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.17 majorServiceTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Service Time Exceeded The Threshold." ::= { systemreporter 17 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.13 criticalAvgCacheUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average Cache Usage Exceeded The Threshold." ::= { systemreporter 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.3 warnServiceTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Service Time Exceeded The Threshold." ::= { systemreporter 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.12 criticalMaxIORespThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Maximum I/O Response Time Exceeded The Threshold." ::= { systemreporter 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.2 warnUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Usage Exceeded The Threshold." ::= { systemreporter 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.5 warnMaxIORespTimeThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Maximum I/O Response Time Exceeded The Threshold." ::= { systemreporter 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.822.20 majorAvgCacheUsageThreshAlarm NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Average Cache Usage Exceeded The Threshold." ::= { systemreporter 20 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.823 serverAgent OBJECT IDENTIFIER ::= { storage 823 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.823.12 serverLinkIsDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Server Link Is Down." ::= { serverAgent 12 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361 hypermetro OBJECT IDENTIFIER ::= { storage 15361 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.3 hyperMetroIsInvalid NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Invalid HyperMetro Pair." ::= { hypermetro 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.1 hyperMetroIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Is Unavailable." ::= { hypermetro 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.4 hyperMetroIsInterrupted NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Pair Interrupted Unexpectedly." ::= { hypermetro 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.2 hostIncorrectAccessForPair NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Host Has An Incorrect Access Permission." ::= { hypermetro 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.0 hyperMetroIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Is Disconnected." ::= { hypermetro 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.7 hyperMetroConfigInterrupt NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Pair Configuration Is Abnormally Interrupted." ::= { hypermetro 7 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15361.8 hyperMetroNasPairIsIsolated NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "One Storage Array Of A HyperMetro Pair Is Isolated ." ::= { hypermetro 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15362 hypermetrodomain OBJECT IDENTIFIER ::= { storage 15362 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15362.0 hyperMetroDomainIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Domain Is Unavailable." ::= { hypermetrodomain 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15363 quorumserver OBJECT IDENTIFIER ::= { storage 15363 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15363.0 quorumServerDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Arbitration Server Is Disconnected From Storage Arrays." ::= { quorumserver 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364 hypermetroconsistencygroup OBJECT IDENTIFIER ::= { storage 15364 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.3 hostIncorrectAccessForGroup NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Host Has An Incorrect Access Permission." ::= { hypermetroconsistencygroup 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.2 hyperMetroGroupIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Consistency Group Is Unavailable." ::= { hypermetroconsistencygroup 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15364.1 hyperMetroGroupIsDisconnected NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro Consistency Group Is Disconnected." ::= { hypermetroconsistencygroup 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15365 quorumserverlink OBJECT IDENTIFIER ::= { storage 15365 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15365.0 quorumLinkDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Quorum Server Link Is Down." ::= { quorumserverlink 0 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446 resourceuser OBJECT IDENTIFIER ::= { storage 16446 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.1 pwdOfResUserIsAboutToExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Password Of The Resource User Is About To Expire." ::= { resourceuser 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.4 resUserHasBeenLocked NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Resource User Has Been Locked." ::= { resourceuser 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.2 pwdOfResUserHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Password Of The Resource User Has Expired." ::= { resourceuser 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16446.3 resUserIsAboutToBeLocked NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Resource User Is About To Be Locked." ::= { resourceuser 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16450 httpservice OBJECT IDENTIFIER ::= { storage 16450 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16450.1 startHttpServiceFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Start The HTTP Service Failed." ::= { httpservice 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16451 ftpservice OBJECT IDENTIFIER ::= { storage 16451 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16451.1 startFtpServiceFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Start The FTP Service Failed." ::= { ftpservice 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453 cifsservice OBJECT IDENTIFIER ::= { storage 16453 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.44 domainDNSServiceUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Domain DNS Service Is Unavailable." ::= { cifsservice 44 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.43 adDomainServiceUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "AD Domain Service Is Unavailable." ::= { cifsservice 43 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.1 auditLogFileSystemAbnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Audit Log File System Is Abnormal." ::= { cifsservice 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16453.2 auditFSFreeCapacityNotEnough NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Available Capacity Of The Audit Log File System Is Insufficient." ::= { cifsservice 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458 filesystemquota OBJECT IDENTIFIER ::= { storage 16458 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.14 fsUsedQuotaExceedsDirQuota NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Used Resource Of A File System Quota Exceeds The Soft Quota." ::= { filesystemquota 14 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.15 fsUsedQuotaExceedsUsrGrpQuota NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Used Resource Of A File System Quota Exceeds The Soft Quota." ::= { filesystemquota 15 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16458.13 fsUsedExceedUserOrGroupSoftQuota NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Used Resource Of A File System Quota Exceeds The Soft Quota." ::= { filesystemquota 13 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350 virtualmachine OBJECT IDENTIFIER ::= { storage 57350 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.104 remainSpaceOfVMfsIsLower NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Remain Space Of The Virtual Machine File System Is Lower Than Threshold Percentage." ::= { virtualmachine 104 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.98 ioErrorsOccurOnVirtualMachine NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Some Read/Write Errors Occur On A Virtual Machine." ::= { virtualmachine 98 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.118 vmFailsShutDown NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "VM Fails To Be Correctly Shut Down Within The Specified Time During Array Power-Off." ::= { virtualmachine 118 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.1 incompleteVirtualMachineCreation NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Incomplete Virtual Machine Creation." ::= { virtualmachine 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.100 errorsOccurredOnHypervisor NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Errors Occurred On Hypervisor When Controlling Virtual Machine." ::= { virtualmachine 100 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.97 virtualMachineIsSuspended NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Virtual Machine Is Suspended." ::= { virtualmachine 97 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.89 virtualMachineCrashes NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Virtual Machine Crashes." ::= { virtualmachine 89 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.114 failedToRestoreVirtualMachine NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Restore A Virtual Machine." ::= { virtualmachine 114 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.103 initVMfileSystemFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Initiate The File System Of A Virtual Machine." ::= { virtualmachine 103 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.105 fileSystemOfVMabnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "The Virtual Machine File System Is Abnormal." ::= { virtualmachine 105 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.57350.116 serviceOfVMabnormal NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "VM Service Is Abnormal." ::= { virtualmachine 116 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452 nfsservice OBJECT IDENTIFIER ::= { storage 16452 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.27 obtainLDAPCertFileFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Obtain The LDAP Certificate File." ::= { nfsservice 27 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.25 ldapServiceUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "LDAP Service Is Unavailable." ::= { nfsservice 25 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.24 getLDAPCertificateFileFailed NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Failed To Get LDAP Certificate File And Restart The NFS Service." ::= { nfsservice 24 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16452.26 nisServiceUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "NIS Service Is Unavailable." ::= { nfsservice 26 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386 protocolcluster OBJECT IDENTIFIER ::= { storage 16386 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.26 cloneNFSShareReachLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "During File System Clone, The Number Of Copied NFS Share Reaches The Limit." ::= { protocolcluster 26 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.27 cloneNFSPermissionReachLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "During File System Clone, The Number Of Copied NFS Share Permissions Reaches The Limit." ::= { protocolcluster 27 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.2 servicePortConflict NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "A Service Port Conflicts." ::= { protocolcluster 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.7 phRecordReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of File Information Items To Be Backed Up Reaches The Upper Limit." ::= { protocolcluster 7 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.9 smb1ShareNumReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Share Connections For SMB One Reaches The Upper Limit." ::= { protocolcluster 9 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.8 smb2ShareNumReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of Share Connections For SMB Two Reaches The Upper Limit." ::= { protocolcluster 8 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.10 fileLockNumReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of File Locks For NAS Reaches The Upper Limit." ::= { protocolcluster 10 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.16386.5 clientConnectionReachUpperLimit NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Number Of NAS Client Connections Of A Controller Reaches The Upper Limit." ::= { protocolcluster 5 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480 certificateManagement OBJECT IDENTIFIER ::= { storage 20480 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.2 certificateWillExpireWithTime NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Is About To Expire." ::= { certificateManagement 2 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.1 certificateExpiredWithDeadline NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Has Expired." ::= { certificateManagement 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.4 tenantCertificateWillExpire NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Is About To Expire." ::= { certificateManagement 4 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.20480.3 tenantCertificateHasExpired NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Certificate Has Expired." ::= { certificateManagement 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366 hyperMetroVstorePair OBJECT IDENTIFIER ::= { storage 15366 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.1 hostIncorrectAccessForVstorePair NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Hosts Access Permissions For A HyperMetro VStore Pair Are Abnormal." ::= { hyperMetroVstorePair 1 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.3 hyperMetroVstoreConfigInterrupt NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "HyperMetro VStore Pair Configuration Is Abnormally Interrupted." ::= { hyperMetroVstorePair 3 } -- 1.3.6.1.4.1.2011.2.91.10.2.1.1.15.15366.2 vstorePairIsUnavailable NOTIFICATION-TYPE OBJECTS { hwIsmReportingAlarmNodeCode, hwIsmReportingAlarmLocationInfo, hwIsmReportingAlarmRestoreAdvice, hwIsmReportingAlarmFaultTitle, hwIsmReportingAlarmFaultType, hwIsmReportingAlarmFaultLevel, hwIsmReportingAlarmAlarmID, hwIsmReportingAlarmFaultTime, hwIsmReportingAlarmSerialNo, hwIsmReportingAlarmLocationAlarmID, hwIsmReportingAlarmFaultCategory, hwIsmReportingAlarmAdditionInfo } STATUS current DESCRIPTION "Invalid HyperMetro VStore Pair." ::= { hyperMetroVstorePair 2 } -- 1.6.1 -- 1.6.1 isoGroups OBJECT IDENTIFIER ::= { isoConformance 1 } -- 1.6.1.1 -- 1.6.1.1 currentNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { ethFCoEPortIsDisconnected, portIsWorkingInHalfDuplexMode, expPortHasTooManyBitErrors, hostPortHasTooManyBitErrors, pciePortIsPartiallyDamaged, pciePortIsDisconnected, expansionPortPartiallyDamaged, expansionPortIsDisconnected, rateIsSmallerThanAllowedMaximum, portNegotiatedRateNotToMaximum, hostPortIsDisconnected, manageNetworkPortIsDisconnected, expansionPortIsolated, managementNetworkPortIsFaulty, pciePortIsFaulty, hostPortIsFaulty, expansionPortIsFaulty, numberOfDisksExceedsUpperLimit, mixtureOfSATAAndNonSATADisks, diskIsIsolated, slowDiskResponse, authenticationOfSEDAccessFails, cofferDiskIsFaulty, cofferDiskFault, diskInEngineMonitoringFailed, diskMonitoringFailed, diskModelIsIncompatible, diskInSingleLinkState, diskIsAboutToFail, cofferDiskModelIsIncompatible, diskTemperatureExceedsUpperLimit, cofferDiskInInccorrectSlot, diskIsRejectedBySystem, cofferDisksNotFound, authenticationOfSEDKeyFails, diskHardwareIsFaulty, diskIsUnrecognizable, svpDiskIsFaulty, svpDiskIsNotInserted, externalLunTypeChanged, lunStartBgrTaskFailed, localArrayRegPathToHeteroFailed, theLUNHasMediumError, theLUNLBAHasWarningMediumError, theLUNLBAHasCriticalMediumError, snapshotLUNIsFault, externalLUNFault, externalLUNToOnlyOneController, remoteLinkExceedUpperLimit, remoteArrayExceedUpperLimit, incompatibleArrayConnected, theLUNIsFault, iscsiLinkFaulty, fcLinkFaulty, iscsiLinkDisconnected, fcLinkDisconnected, theLUNIsFault, snapshotLUNIsFault, noRedundantConnectionToHost, aLinkToHostIsDown, ultrapathIncompatibleWithStorage, powerModuleIsFaulty, powerModuleInputIsAbnormal, powerModulesTypesDifferent, diskEnclHasNoRePowerModule, powerModuleIsIncompatible, failedToMonitorAPowerModule, powerModuleIsRemoved, powerModuleFaulty, powerModuleHasNoInput, powerModuleTempExceedsLimit, snapshotStopAbnormally, snapshotUnavailable, failedToDisableTheSnapshot, fsObjectIsIsolated, fsRemainCapacityIsInsufficient, fileSystemExistMediumError, fileOrDirExistMediumError, openedFilesNumAboutToExceedThres, filesNumAboutToExceedThreshold, filesNumExceedLimit, openedFilesNumExceedLimit, filesNumAboutToExceedLimit, dirFilesNumAboutToExceedLimit, filesNumReachedOrExceededLimit, dirFilesNumExceededLimit, openedFilesNumExceededLimit, subFilesNumToExceedLimit, subFilesNumAboutToExceedLimit, fileSystemMetadataIsDamaged, fileOrDirDamagedInFs, fileSystemIsFaulty, writeProtectionIsEnabledForFS, eventAmountReachUpLimit, controllerWriteCacheIsDisabled, dnsIsUnavailable, ipaddrConflict, onlyOneClusterLinkIsAvailable, systemEnterSafeMode, userInfoNeedReview, passwdOfUserHasExpired, passwdOfUserIsAboutToExpire, passwdOfUserHasExpired, passwdOfUserIsAboutToExpire, enclosureIsFaulty, failedToMonitorTheRearPanel, highDensityAreMixConnected, numOfEnclOnExpPortExceedsLimit, failedToIdentifyEnclosure, enclosureIsUnrecognizable, enclosureCablingIsIncorrect, faultsOccurredOnEnclosure, diskEnclTempExceedsUpperLimit, diskEnclTempIsBelowLimit, ctrlEnclTempExceedsUpperLimit, ctrlEnclTempIsFarBeyondUpLimit, diskEnclTempIsFarBeyondUpLimit, enclSpeedSmallerThanLoopSpeed, anUnsupportedExpEnclConnected, diskEnclosureIsSingleLink, failedToMonitorADiskEnclosure, monitorControllerFailed, abnormalCommunicateBetweenCtrls, controllerCannotBeMonitored, controllerServicesAbnormal, controllerIsFaulty, bbuIsFault, ctrlAndMgtCommunicateLinkFault, controllerIsFaulty, controllerIsOffline, portIsIncorrectlyConnected, controllerIsRemoved, theCoinBatteryIsFaulty, ftpServiceIsAbnormal, processCpuUsageIsTooHigh, sshServiceIsAbnormal, bbuIsFault, ntpSynchronizationIsAbnormal, excessiveFilesExistInADirectory, processMemoryUsageIsTooHigh, directoryIsOversized, openedFilesNumAboutToExceedLimit, remainAvailableMemoryTooLow, cpuUsageTooHigh, memoryUsageTooHigh, firmwareVersionIncompatible, controllerNetStackIsAbnormal, bbuTempHigh, cpuUsageIsTooHigh, monitorControllersFailed, memoryCapacityIsNotSupported, expansionModuleIsFaulty, syncExpansionFirmwareFailed, sasExpansionModuleIncompatible, expansionModuleIncompatible, expansionCableLinkError, expansionModuleIsRemoved, expansionModuleIsNotInserted, expansionModuleFaulty, abnormalCommBetweenExpModules, interfaceModuleIsRemoved, interfaceModuleIsUnrecognizable, incorrectRemovalInterfaceModule, interfaceModuleTempExceedsLimit, monitorInterfaceModuleFailed, failedToMonitorTheInternalLink, internalLinkofIntfModIsFaulty, faultyInterfaceModuleComponent, managementModuleIncompatible, communicationIsFaulty, interfaceModuleIncompatible, managementModuleIsFaulty, managementModuleIsAbnormal, pcieChannelIsFaulty, someStatusMonitoringFailed, interfaceModuleIsFaulty, pcieChannelIsAbnormal, slotDoesNotMatchInterfaceModule, bbuModuleIsFaulty, bbuModuleLifeIsOvertime, bbuModuleIsAboutToExpire, bbuModuleTempExceedsLimit, failedToMonitorABBUModule, bbuFirmwareIncompatible, bbuModuleIsRemoved, bbuModuleTypeDoesNotComply, bbuModuleTempIsBelowLimit, fanModuleIsRemoved, fanModuleIsFaulty, ckgMetadataHasFaults, extentMetadataOfVolumeHasFaults, usedCapacityReachAlarmThreshold, availableSpaceInsufficient, smartTierUnavailable, availableSpaceUsedUp, storagePoolCapacityShouldUseUp, storagePoolCapacityNotEnough, smartCacheDiskIsFaulty, almCpyFullCopyFail, almCLnPairInterrupt, almClnPairFault, remoteReplicationCGAutoSplit, remoteReplicationCGIsUnavailable, remoteReplicationCGIsInterrupted, noBackupLinkForRep, repLinkDown, switchFanModuleIsFaulty, powerSupplyOfSwitchIsFaulty, switchPowerInputIsAbnormal, switchFanModuleIsRemoved, negoRateSmallerThanTheMax, switchPortOpticalModuleIsFaulty, switchFailToMonitorPowModules, switchIsFaulty, switchTempExceedsLimit, switchManageNetworkPortIsFaulty, switchPowerModuleIsRemoved, switchFailedToBeMonitored, switchTempIsBelowLimit, switchPortIsFaulty, linkToASwitchPortIsAbnormal, dswEthPortIsDown, failedToMonitorSwitchOpModule, switchFailToMonitorFanModules, portOpticalModuleIsFaulty, opticalModuleRateIsInconsistent, failedToMonitorOpOrEleModule, portLinkIsAbnormal, failedToMonitorAnOpticalModule, licenseIsAboutToExpire, licenseHasExpired, licenseIsInvalidWithStartDate, almSmartMigrationErr, autoStartSynRemoteRepFails, remoteReplicationIsInterrupted, remoteReplicationIsInvalid, autoStartSynRemoteRepCGFails, remoteReplicationAutomaticSplit, fsRemoteReplicationPairInvalid, fsRemoteReplicationPairFault, fsRemoteReplicationAutoSyncFail, failedRecoverRmReplication, addRemoteReplicationToCGFails, diskDomainEnterSecureVideoState, diskDomainIsOffline, diskDomainFault, diskDomainDegradation, backgroudTaskFailedToStart, differentDiskType, hotSpareCapacityInsufficient, diskIsRemovedFromDiskDomain, newDiskCapacityInsufficieny, controllerWriteCacheDisabled, cachePartitionWriteCacheDisabled, failReachSmartQoSObjective, smartcacheIsFaulty, antivirusServiceIsNotAvailable, antivirusServerIsFault, hyperVaultJobCongestion, hyperVaultScheduledTaskFailure, hyperVaultCopiesReachUpperLimit, hyperVaultLinkIsFaulty, hyperVaultFileSystemFaults, hyperVaultPairInvalid, hyperVaultInterruption, assistCoolingUnitMonitorFailed, assistantCoolingUnitNotPresent, coolingUnitIsUnrecognizable, svpCpuUsageIsTooHigh, svpFanModuleIsFaulty, svpEnclosureTemperatureIsHigh, svpCPUTemperatureIsHigh, svpMainboardIsFaultyWithErrCode, svpLUNDegrades, svpPowerModuleIsFaulty, svpPowerModuleAbnormal, manageStorageEquipmentFailed, manageSVPFailed, svpProcessCpuUsageIsTooHigh, svpNtpSynchronizationIsAbnormal, svpProcessMemoryUsageIsTooHigh, svpDirectoryExcessiveFilesExist, svpDirectoryIsOversized, svpMemoryUsageIsTooHigh, almLunMirrorCopyErr, almLunMirrorCopyUnavailable, blockDeviceIsFaulty, caCertificateIsExpiring, caCertificateHasExpired, operationLogsExceedsUpperLimit, sshServiceUntrust, majorUsageThreshAlarm, criticalAvgCpuUsageThreshAlarm, warnTimeSinceLastSyncThreshAlarm, criticalAvgIORespThreshAlarm, criticalServiceTimeThreshAlarm, warnAvgCpuUsageThreshAlarm, majorMaxIORespTimeThreshAlarm, majorAvgIORespTimeThreshAlarm, majorTimeSinceSyncThreshAlarm, warnAvgCacheUsageThreshAlarm, warnAvgIORespTimeThreshAlarm, majorAvgCpuUsageThreshAlarm, criticalTimeSinceSyncThreshAlarm, criticalUsageThreshAlarm, majorServiceTimeThreshAlarm, criticalAvgCacheUsageThreshAlarm, warnServiceTimeThreshAlarm, criticalMaxIORespThreshAlarm, warnUsageThreshAlarm, warnMaxIORespTimeThreshAlarm, majorAvgCacheUsageThreshAlarm, serverLinkIsDown, hyperMetroIsInvalid, hyperMetroIsUnavailable, hyperMetroIsInterrupted, hostIncorrectAccessForPair, hyperMetroIsDisconnected, hyperMetroConfigInterrupt, hyperMetroNasPairIsIsolated, hyperMetroDomainIsUnavailable, quorumServerDisconnected, hostIncorrectAccessForGroup, hyperMetroGroupIsUnavailable, hyperMetroGroupIsDisconnected, quorumLinkDown, pwdOfResUserIsAboutToExpire, resUserHasBeenLocked, pwdOfResUserHasExpired, resUserIsAboutToBeLocked, startHttpServiceFailed, startFtpServiceFailed, domainDNSServiceUnavailable, adDomainServiceUnavailable, auditLogFileSystemAbnormal, auditFSFreeCapacityNotEnough, fsUsedQuotaExceedsDirQuota, fsUsedQuotaExceedsUsrGrpQuota, fsUsedExceedUserOrGroupSoftQuota, remainSpaceOfVMfsIsLower, ioErrorsOccurOnVirtualMachine, vmFailsShutDown, incompleteVirtualMachineCreation, errorsOccurredOnHypervisor, virtualMachineIsSuspended, virtualMachineCrashes, failedToRestoreVirtualMachine, initVMfileSystemFailed, fileSystemOfVMabnormal, serviceOfVMabnormal, obtainLDAPCertFileFailed, ldapServiceUnavailable, getLDAPCertificateFileFailed, nisServiceUnavailable, cloneNFSShareReachLimit, cloneNFSPermissionReachLimit, servicePortConflict, phRecordReachUpperLimit, smb1ShareNumReachUpperLimit, smb2ShareNumReachUpperLimit, fileLockNumReachUpperLimit, clientConnectionReachUpperLimit, certificateWillExpireWithTime, certificateExpiredWithDeadline, tenantCertificateWillExpire, tenantCertificateHasExpired, hostIncorrectAccessForVstorePair, hyperMetroVstoreConfigInterrupt, vstorePairIsUnavailable } STATUS current DESCRIPTION "Enter the description of the created NOTIFICATION-GROUP." ::= { isoGroups 1 } END -- -- ISM-HUAWEI-OID-BASED-TRAP-MIB.mib --