-- ***************************************************************** -- EKINOPS-Pmops.TXT: MIB -- --MIB Part Number:3MI00303AFAD --MIB Version:01 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pmops-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePmops MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "MIB for the Ekinops Pmops hardware." REVISION "200712110000Z" DESCRIPTION "Initial Version." REVISION "200801230000Z" DESCRIPTION "Helps on objects, Ports Labels" REVISION "200909240000Z" DESCRIPTION "CondType parameters insertion" REVISION "201002260000Z" DESCRIPTION "Probcause,AlarmType - NMS" REVISION "201005270000Z" DESCRIPTION "Dummy INV for NMS" REVISION "201011040000Z" DESCRIPTION "Formulas in comments" REVISION "201012150000Z" DESCRIPTION "Formulas in comments" REVISION "201207040000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403260000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201411210000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 30 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmopsalarms OBJECT IDENTIFIER ::= { modulePmops 2 } pmopsAlmOther OBJECT IDENTIFIER ::= { pmopsalarms 1 } pmopsAlmOtherNurg OBJECT IDENTIFIER ::= { pmopsAlmOther 1 } pmopsAlmOtherUrg OBJECT IDENTIFIER ::= { pmopsAlmOther 2 } pmopsAlmOtherCrit OBJECT IDENTIFIER ::= { pmopsAlmOther 3 } pmopsAlmComa OBJECT IDENTIFIER ::= { pmopsalarms 2 } pmopsAlmComaNurg OBJECT IDENTIFIER ::= { pmopsAlmComa 1 } pmopsAlmComaUrg OBJECT IDENTIFIER ::= { pmopsAlmComa 2 } pmopsAlmComaCrit OBJECT IDENTIFIER ::= { pmopsAlmComa 3 } pmopsAlmComb OBJECT IDENTIFIER ::= { pmopsalarms 3 } pmopsAlmCombNurg OBJECT IDENTIFIER ::= { pmopsAlmComb 1 } pmopsAlmCombUrg OBJECT IDENTIFIER ::= { pmopsAlmComb 2 } pmopsAlmCombCrit OBJECT IDENTIFIER ::= { pmopsAlmComb 3 } pmopsmeasures OBJECT IDENTIFIER ::= { modulePmops 3 } pmopsMesrOther OBJECT IDENTIFIER ::= { pmopsmeasures 1 } pmopsMesrComa OBJECT IDENTIFIER ::= { pmopsmeasures 2 } pmopsMesrComb OBJECT IDENTIFIER ::= { pmopsmeasures 3 } pmopscontrolsWrite OBJECT IDENTIFIER ::= { modulePmops 6 } pmopsCtrlOther OBJECT IDENTIFIER ::= { pmopscontrolsWrite 1 } pmopsCtrlComa OBJECT IDENTIFIER ::= { pmopscontrolsWrite 2 } pmopsCtrlComb OBJECT IDENTIFIER ::= { pmopscontrolsWrite 3 } pmopsri OBJECT IDENTIFIER ::= { modulePmops 7 } pmopsriTable OBJECT IDENTIFIER ::= { pmopsri 1 } pmopsConfig OBJECT IDENTIFIER ::= { modulePmops 9 } pmopstraps OBJECT IDENTIFIER ::= { modulePmops 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** PmopsSwitchMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "different switch mode for port" SYNTAX INTEGER { switchManual1(1), switchManual2(2), switchAuto(4), switchAutoRevertive(8) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmopsRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmopsri 2 } pmopsRinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pmopsri 3 } pmopsRinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmopsri 4 } pmopsRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmopsri 5 } pmopsRinvLine1SFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the OPS: This OID contains the inventory for the OPS A" ::= { pmopsri 6 } pmopsRinvLine2SFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the OPS: This OID contains the inventory for the OPS B" ::= { pmopsri 7 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmopsAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmopsAlmOtherCrit 0 } pmopsAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmopsAlmsynthAlm0 16 } pmopsAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmopsAlmsynthAlm0 15 } pmopsAlmModuleGlobFailure OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MODULE_GLOB_FAILURE equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmopsAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmopsAlmOtherNurg 2 } pmopsAlmCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This OID, when set, indicates that alarm correlation is not being performed. CORRELAT_OFF other (1) other (1) (2) " ::= { pmopsAlmsynthAlm2 4 } pmopsAlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD other (1) other (1) (2) " ::= { pmopsAlmsynthAlm2 3 } pmopsAlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD other (1) other (1) (2) " ::= { pmopsAlmsynthAlm2 2 } pmopsAlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE other (1) other (1) (2) " ::= { pmopsAlmsynthAlm2 1 } --- ***************************************************** --- LEAF for the synthAlmComa article --- ***************************************************** pmopsAlmsynthAlmComa OBJECT IDENTIFIER ::= { pmopsAlmComaCrit 8 } pmopsAlmComaFailAcc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fail_Acc :This OID indicates a failure on the OPS A COMA_FAIL_ACC equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComa 12 } pmopsAlmComaMeasAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Measure Alarm :This OID indicates an alarm is present coming out of OPS A diagnostic monitoring This alarm indicates if a diagnostic monitoring Alarm has been detected on the OPS A COMA_MEAS_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComa 10 } pmopsAlmComaMeasWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Measure Warning :This OID indicates a warning is present coming out of OPS A diagnostic monitoring This alarm indicates if a diagnostic monitoring Warning has been detected on the OPS A COMA_MEAS_WNG equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComa 9 } pmopsAlmComaLocalOos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Out Of Service :This OID indicates that the OPS A is In Service (1) of Out or Service (2). This status indicates if the OPS A is in service COMA_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pmopsAlmsynthAlmComa 6 } pmopsAlmComaHwFailAcc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " HW_Fail_Acc :This OID indicates a hardware failure on the OPS A COMA_HW_FAIL_ACC equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComa 4 } --- ***************************************************** --- LEAF for the synthAlmComb article --- ***************************************************** pmopsAlmsynthAlmComb OBJECT IDENTIFIER ::= { pmopsAlmCombCrit 9 } pmopsAlmCombFailAcc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fail_Acc :This OID indicates a failure on the OPS B COMB_FAIL_ACC equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComb 12 } pmopsAlmCombMeasAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Measure Alarm :This OID indicates an alarm is present coming out of OPS B diagnostic monitoring This alarm indicates if a diagnostic monitoring Alarm has been detected on the OPS B COMB_MEAS_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComb 10 } pmopsAlmCombMeasWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Measure Warning :This OID indicates a warning is present coming out of OPS B diagnostic monitoring This alarm indicates if a diagnostic monitoring Warning has been detected on the OPS B COMB_MEAS_WNG equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComb 9 } pmopsAlmCombLocalOos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Out Of Service :This OID indicates that the OPS B is In Service (1) of Out or Service (2). This status indicates if the OPS B is in service COMB_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pmopsAlmsynthAlmComb 6 } pmopsAlmCombHwFailAcc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " HW_Fail_Acc :This OID indicates a hardware failure on the OPS B COMB_HW_FAIL_ACC equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmopsAlmsynthAlmComb 4 } --- ***************************************************** --- LEAF for the comaAccessioAlm article --- ***************************************************** pmopsAlmcomaAccessioAlm OBJECT IDENTIFIER ::= { pmopsAlmComaUrg 16 } pmopsAlmComaSwitchFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Switch Fail :This OID indicates the OPS A switch component in in fail condition This alarm indicates if the OPS A swithc is in fail condition COMA_SWITCH_FAIL equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaAccessioAlm 8 } pmopsAlmComaSwitchPosition2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Selected :This OID indicates the OPS A selects the RX 2 input This status indicates if the RX2 input is selected on the OPS A COMA_SWITCH_POSITION_2 other (1) other (1) (2) " ::= { pmopsAlmcomaAccessioAlm 6 } pmopsAlmComaSwitchPosition1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Selected :This OID indicates the OPS A selects the RX 1 input This status indicates if the RX 1 input is selected on the OPS A COMA_SWITCH_POSITION_1 other (1) other (1) (2) " ::= { pmopsAlmcomaAccessioAlm 5 } pmopsAlmComaLosTx2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TX2 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 2 of the OPS A This alarm indicates if an optical signal is detected on the TX 2 of the OPS A COMA_LOS_TX_2 transmitFailure (55) physicalViolation (9) (2) " ::= { pmopsAlmcomaAccessioAlm 4 } pmopsAlmComaLosTx1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TX1 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 1 of the OPS A This alarm indicates if an optical signal is detected on the TX 1 of the OPS A COMA_LOS_TX_1 transmitFailure (55) physicalViolation (9) (2) " ::= { pmopsAlmcomaAccessioAlm 3 } pmopsAlmComaLosRx2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 2 of the OPS A This alarm indicates if an optical signal is detected on the RX 2 of the OPS A COMA_LOS_RX_2 receiveFailure (41) physicalViolation (9) (2) " ::= { pmopsAlmcomaAccessioAlm 2 } pmopsAlmComaLosRx1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 1 of the OPS A This alarm indicates if an optical signal is detected on the RX 1 of the OPS A COMA_LOS_RX_1 receiveFailure (41) physicalViolation (9) (2) " ::= { pmopsAlmcomaAccessioAlm 1 } --- ***************************************************** --- LEAF for the comaMeasAlm article --- ***************************************************** pmopsAlmcomaMeasAlm OBJECT IDENTIFIER ::= { pmopsAlmComaUrg 17 } pmopsAlmComaRx2PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 High Alarm : This OID indicates that Receive power or the OPS A is higher than the alarm threshold of the OPS A This alarm indicates if the receive power on the receive side of the OPS A is too high COMA_RX2_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 8 } pmopsAlmComaRx2PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 Low Alarm :This OID indicates that Receive power or the OPS A is lower than the alarm threshold of the OPS A This alarm indicates if the receive power on the receive side of the OPS A is too low COMA_RX2_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 7 } pmopsAlmComaTx2PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 High Alarm : This OID indicates that Transmit power or the OPS A is higher than the alarm threshold of the OPS A This alarm indicates if the receive power on the transmit side of the OPS A is too high COMA_TX2_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 6 } pmopsAlmComaTx2PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 Low Alarm :This OID indicates that Transmit power or the OPS A is lower than the alarm threshold of the OPS A This alarm indicates if the receive power on the transmit side of the OPS A is too low COMA_TX2_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 5 } pmopsAlmComaRx1PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 High Alarm : This OID indicates that Receive power or the OPS A is higher than the alarm threshold of the OPS A This alarm indicates if the receive power on the receive side of the OPS A is too high COMA_RX1_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 4 } pmopsAlmComaRx1PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 Low Alarm :This OID indicates that Receive power or the OPS A is lower than the alarm threshold of the OPS A This alarm indicates if the receive power on the receive side of the OPS A is too low COMA_RX1_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 3 } pmopsAlmComaTx1PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 High Alarm : This OID indicates that Transmit power or the OPS A is higher than the alarm threshold of the OPS A This alarm indicates if the receive power on the transmit side of the OPS A is too high COMA_TX1_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 2 } pmopsAlmComaTx1PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 Low Alarm :This OID indicates that Transmit power or the OPS A is lower than the alarm threshold of the OPS A This alarm indicates if the receive power on the transmit side of the OPS A is too low COMA_TX1_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasAlm 1 } --- ***************************************************** --- LEAF for the comaMeasWng article --- ***************************************************** pmopsAlmcomaMeasWng OBJECT IDENTIFIER ::= { pmopsAlmComaNurg 18 } pmopsAlmComaRx2PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 High Warning : This OID indicates that Receive power or the OPS A is higher than the warning threshold of the OPS A This warning indicates if the receive power on the receive side of the OPS A is too high COMA_RX2_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 8 } pmopsAlmComaRx2PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 Low Warning :This OID indicates that Receive power or the OPS A is lower than the warning threshold of the OPS A This warning indicates if the receive power on the receive side of the OPS A is too low COMA_RX2_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 7 } pmopsAlmComaTx2PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 High Warning : This OID indicates that Transmit power or the OPS A is higher than the warning threshold of the OPS A This warning indicates if the receive power on the transmit side of the OPS A is too high COMA_TX2_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 6 } pmopsAlmComaTx2PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 Low Warning :This OID indicates that Transmit power or the OPS A is lower than the warning threshold of the OPS A This warning indicates if the receive power on the transmit side of the OPS A is too low COMA_TX2_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 5 } pmopsAlmComaRx1PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 High Warning : This OID indicates that Receive power or the OPS A is higher than the warning threshold of the OPS A This warning indicates if the receive power on the receive side of the OPS A is too high COMA_RX1_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 4 } pmopsAlmComaRx1PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 Low Warning :This OID indicates that Receive power or the OPS A is lower than the warning threshold of the OPS A This warning indicates if the receive power on the receive side of the OPS A is too low COMA_RX1_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 3 } pmopsAlmComaTx1PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 High Warning : This OID indicates that Transmit power or the OPS A is higher than the warning threshold of the OPS A This warning indicates if the receive power on the transmit side of the OPS A is too high COMA_TX1_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 2 } pmopsAlmComaTx1PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 Low Warning :This OID indicates that Transmit power or the OPS A is lower than the warning threshold of the OPS A This warning indicates if the receive power on the transmit side of the OPS A is too low COMA_TX1_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcomaMeasWng 1 } --- ***************************************************** --- LEAF for the combAccessioAlm article --- ***************************************************** pmopsAlmcombAccessioAlm OBJECT IDENTIFIER ::= { pmopsAlmCombUrg 24 } pmopsAlmCombSwitchFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Switch Fail :This OID indicates the OPS B switch component in in fail condition This alarm indicates if the OPS B swithc is in fail condition COMB_SWITCH_FAIL equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmopsAlmcombAccessioAlm 8 } pmopsAlmCombSwitchPosition2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Selected :This OID indicates the OPS B selects the RX 2 input This status indicates if the RX2 input is selected on the OPS B COMB_SWITCH_POSITION_2 other (1) other (1) (2) " ::= { pmopsAlmcombAccessioAlm 6 } pmopsAlmCombSwitchPosition1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Selected :This OID indicates the OPS B selects the RX 1 input This status indicates if the RX 1 input is selected on the OPS B COMB_SWITCH_POSITION_1 other (1) other (1) (2) " ::= { pmopsAlmcombAccessioAlm 5 } pmopsAlmCombLosTx2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TX2 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 2 of the OPS B This alarm indicates if an optical signal is detected on the TX 2 of the OPS B COMB_LOS_TX_2 transmitFailure (55) physicalViolation (9) (2) " ::= { pmopsAlmcombAccessioAlm 4 } pmopsAlmCombLosTx1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TX1 Loss Of Signal :This OID indicates that a LOS is detected on the Transmit 1 of the OPS B This alarm indicates if an optical signal is detected on the TX 1 of the OPS B COMB_LOS_TX_1 transmitFailure (55) physicalViolation (9) (2) " ::= { pmopsAlmcombAccessioAlm 3 } pmopsAlmCombLosRx2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 2 of the OPS B This alarm indicates if an optical signal is detected on the RX 2 of the OPS B COMB_LOS_RX_2 receiveFailure (41) physicalViolation (9) (2) " ::= { pmopsAlmcombAccessioAlm 2 } pmopsAlmCombLosRx1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Loss Of Signal :This OID indicates that a LOS is detected on the Receive 1 of the OPS B This alarm indicates if an optical signal is detected on the RX 1 of the OPS B COMB_LOS_RX_1 receiveFailure (41) physicalViolation (9) (2) " ::= { pmopsAlmcombAccessioAlm 1 } --- ***************************************************** --- LEAF for the combMeasAla article --- ***************************************************** pmopsAlmcombMeasAla OBJECT IDENTIFIER ::= { pmopsAlmCombUrg 25 } pmopsAlmCombRx2PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 High Alarm : This OID indicates that Receive power or the OPS B is higher than the alarm threshold of the OPS B This alarm indicates if the receive power on the receive side of the OPS B is too high COMB_RX2_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 8 } pmopsAlmCombRx2PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 Low Alarm :This OID indicates that Receive power or the OPS B is lower than the alarm threshold of the OPS B This alarm indicates if the receive power on the receive side of the OPS B is too low COMB_RX2_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 7 } pmopsAlmCombTx2PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 High Alarm : This OID indicates that Transmit power or the OPS B is higher than the alarm threshold of the OPS B This alarm indicates if the receive power on the transmit side of the OPS B is too high COMB_TX2_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 6 } pmopsAlmCombTx2PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 Low Alarm :This OID indicates that Transmit power or the OPS B is lower than the alarm threshold of the OPS B This alarm indicates if the receive power on the transmit side of the OPS B is too low COMB_TX2_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 5 } pmopsAlmCombRx1PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 High Alarm : This OID indicates that Receive power or the OPS B is higher than the alarm threshold of the OPS B This alarm indicates if the receive power on the receive side of the OPS B is too high COMB_RX1_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 4 } pmopsAlmCombRx1PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 Low Alarm :This OID indicates that Receive power or the OPS B is lower than the alarm threshold of the OPS B This alarm indicates if the receive power on the receive side of the OPS B is too low COMB_RX1_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 3 } pmopsAlmCombTx1PwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 High Alarm : This OID indicates that Transmit power or the OPS B is higher than the alarm threshold of the OPS B This alarm indicates if the receive power on the transmit side of the OPS B is too high COMB_TX1_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 2 } pmopsAlmCombTx1PwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 Low Alarm :This OID indicates that Transmit power or the OPS B is lower than the alarm threshold of the OPS B This alarm indicates if the receive power on the transmit side of the OPS B is too low COMB_TX1_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasAla 1 } --- ***************************************************** --- LEAF for the combMeasWng article --- ***************************************************** pmopsAlmcombMeasWng OBJECT IDENTIFIER ::= { pmopsAlmCombNurg 26 } pmopsAlmCombRx2PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 High Warning : This OID indicates that Receive power or the OPS B is higher than the warning threshold of the OPS B This warning indicates if the receive power on the receive side of the OPS B is too high COMB_RX2_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 8 } pmopsAlmCombRx2PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx2 Low Warning :This OID indicates that Receive power or the OPS B is lower than the warning threshold of the OPS B This warning indicates if the receive power on the receive side of the OPS B is too low COMB_RX2_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 7 } pmopsAlmCombTx2PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 High Warning : This OID indicates that Transmit power or the OPS B is higher than the warning threshold of the OPS B This warning indicates if the receive power on the transmit side of the OPS B is too high COMB_TX2_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 6 } pmopsAlmCombTx2PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx2 Low Warning :This OID indicates that Transmit power or the OPS B is lower than the warning threshold of the OPS B This warning indicates if the receive power on the transmit side of the OPS B is too low COMB_TX2_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 5 } pmopsAlmCombRx1PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 High Warning : This OID indicates that Receive power or the OPS B is higher than the warning threshold of the OPS B This warning indicates if the receive power on the receive side of the OPS B is too high COMB_RX1_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 4 } pmopsAlmCombRx1PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Rx1 Low Warning :This OID indicates that Receive power or the OPS B is lower than the warning threshold of the OPS B This warning indicates if the receive power on the receive side of the OPS B is too low COMB_RX1_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 3 } pmopsAlmCombTx1PwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 High Warning : This OID indicates that Transmit power or the OPS B is higher than the warning threshold of the OPS B This warning indicates if the receive power on the transmit side of the OPS B is too high COMB_TX1_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 2 } pmopsAlmCombTx1PwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Tx1 Low Warning :This OID indicates that Transmit power or the OPS B is lower than the warning threshold of the OPS B This warning indicates if the receive power on the transmit side of the OPS B is too low COMB_TX1_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmopsAlmcombMeasWng 1 } --- ***************************************************** --- LEAF for the modInitFailLevel2 article --- ***************************************************** pmopsAlmmodInitFailLevel2 OBJECT IDENTIFIER ::= { pmopsAlmOtherUrg 70 } pmopsAlmThreshConfFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Thresh_Conf_Fail : THRESH_CONF_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 7 } pmopsAlmCalibReadFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Calib_Read_Fail : CALIB_READ_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 6 } pmopsAlmGwIdentFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW_Ident_Fail :This OID indicates that GW identification has not been read GW_IDENT_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 5 } pmopsAlmConfReadFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Conf_Read_Fail : CONF_READ_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 3 } pmopsAlmResetHwInitFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Reset_HW_Init_Fail : RESET_HW_INIT_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 2 } pmopsAlmRegReadFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Reg_Read_Fail : REG_READ_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel2 1 } --- ***************************************************** --- LEAF for the modInitFailLevel3 article --- ***************************************************** pmopsAlmmodInitFailLevel3 OBJECT IDENTIFIER ::= { pmopsAlmOtherUrg 71 } pmopsAlmGwColdBootForced OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW_Cold_Boot_Forced : GW_COLD_BOOT_FORCED other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel3 5 } pmopsAlmOptIdentFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Opt_Ident_Fail : OPT_IDENT_FAIL other (1) other (1) (2) " ::= { pmopsAlmmodInitFailLevel3 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmopsCtrlsynth0 OBJECT IDENTIFIER ::= { pmopsCtrlOther 0 } pmopsCtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmopsCtrlsynth0 13 } pmopsCtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmopsCtrlsynth0 9 } pmopsCtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmopsCtrlsynth0 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pmopsCtrlsynth4 OBJECT IDENTIFIER ::= { pmopsCtrlOther 4 } pmopsCtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM. " ::= { pmopsCtrlsynth4 2 } pmopsCtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM. " ::= { pmopsCtrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmopsCtrlswMgnt OBJECT IDENTIFIER ::= { pmopsCtrlOther 5 } pmopsCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmopsCtrlswMgnt 3 } pmopsCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmopsCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the comaSwitchMode article --- ***************************************************** pmopsCtrlcomaSwitchMode OBJECT-TYPE SYNTAX PmopsSwitchMode MAX-ACCESS read-write STATUS current DESCRIPTION " Switch Mode :This OID sets the switch mode of the OPS A This control defines the switch mode of the OPS A (Manual 1, Manual 2, Auto reversive or auto no reversive) " ::= { pmopsCtrlComa 16 } --- ***************************************************** --- LEAF for the combSwitchMode article --- ***************************************************** pmopsCtrlcombSwitchMode OBJECT-TYPE SYNTAX PmopsSwitchMode MAX-ACCESS read-write STATUS current DESCRIPTION " Switch Mode :This OID sets the switch mode of the OPS B This control defines the switch mode of the OPS B (Manual 1, Manual 2, Auto reversive or auto no reversive) " ::= { pmopsCtrlComb 17 } --- ***************************************************** --- LEAF for the comaOosMode article --- ***************************************************** pmopsCtrlcomaOosMode OBJECT IDENTIFIER ::= { pmopsCtrlComa 18 } pmopsCtrlComaOosMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Out Of Service :This OID sets the OPS A Out of Service This controls defines the service state of the OPS A " ::= { pmopsCtrlcomaOosMode 1 } --- ***************************************************** --- LEAF for the combOosMode article --- ***************************************************** pmopsCtrlcombOosMode OBJECT IDENTIFIER ::= { pmopsCtrlComb 19 } pmopsCtrlCombOosMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Out Of Service :This OID sets the OPS B Out of Service This controls defines the service state of the OPS B " ::= { pmopsCtrlcombOosMode 1 } --- ***************************************************** --- LEAF for the comaRxPwrSetting1 article --- ***************************************************** pmopsCtrlcomaRxPwrSetting1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " RX1 Loss Threshold :This OID sets the LOS detection threshold on the RX1 of the OPS A (AV=Power/0.005 + 32768) (Unit = dBm) This control defines the LOS threshold (in dBm) on the RX1 of the OPS A " ::= { pmopsCtrlComa 24 } --- ***************************************************** --- LEAF for the comaRxPwrSetting2 article --- ***************************************************** pmopsCtrlcomaRxPwrSetting2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " RX2 Loss Threshold :This OID sets the LOS detection threshold on the RX2 of the OPS A (AV=Power/0.005 + 32768) (Unit = dBm) This control defines the LOS threshold (in dBm) on the RX2 of the OPS A " ::= { pmopsCtrlComa 25 } --- ***************************************************** --- LEAF for the combRxPwrSetting1 article --- ***************************************************** pmopsCtrlcombRxPwrSetting1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " RX1 Loss Threshold :This OID sets the LOS detection threshold on the RX1 of the OPS B (AV=Power/0.005 + 32768) (Unit = dBm) This control defines the LOS threshold (in dBm) on the RX1 of the OPS B " ::= { pmopsCtrlComb 26 } --- ***************************************************** --- LEAF for the combRxPwrSetting2 article --- ***************************************************** pmopsCtrlcombRxPwrSetting2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " RX2 Loss Threshold :This OID sets the LOS detection threshold on the RX2 of the OPS B (AV=Power/0.005 + 32768) (Unit = dBm) This control defines the LOS threshold (in dBm) on the RX2 of the OPS B " ::= { pmopsCtrlComb 27 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmopsCtrlledTest OBJECT IDENTIFIER ::= { pmopsCtrlOther 64 } pmopsCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmopsCtrlledTest 3 } pmopsCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmopsCtrlledTest 2 } pmopsCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmopsCtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the comaTxPower1 article --- ***************************************************** pmopsMesrcomaTxPower1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " TX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Transmit optical power on the TX1 of the OPS A " ::= { pmopsMesrComa 16 } --- ***************************************************** --- LEAF for the comaTxPower2 article --- ***************************************************** pmopsMesrcomaTxPower2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " TX2 Power :This OID gives the transmit power value of the signal , read on the coupler output 2 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Transmit optical power on the TX2 of the OPS A " ::= { pmopsMesrComa 17 } --- ***************************************************** --- LEAF for the comaRxPower1 article --- ***************************************************** pmopsMesrcomaRxPower1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Receive optical power on the RX1 of the OPS A " ::= { pmopsMesrComa 18 } --- ***************************************************** --- LEAF for the comaRxPower2 article --- ***************************************************** pmopsMesrcomaRxPower2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Power :This OID gives the receive power value of the signal , read on the switch input 2 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Receive optical power on the RX2 of the OPS A " ::= { pmopsMesrComa 19 } --- ***************************************************** --- LEAF for the combTxPower1 article --- ***************************************************** pmopsMesrcombTxPower1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " TX1 Power :This OID gives the transmit power value of the signal , read on the coupler output 1 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Transmit optical power on the TX1 of the OPS B " ::= { pmopsMesrComb 24 } --- ***************************************************** --- LEAF for the combTxPower2 article --- ***************************************************** pmopsMesrcombTxPower2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " TX2 Power :This OID gives the transmit power value of the signal , read on the coupler output 2 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Transmit optical power on the TX2 of the OPS B " ::= { pmopsMesrComb 25 } --- ***************************************************** --- LEAF for the combRxPower1 article --- ***************************************************** pmopsMesrcombRxPower1 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " RX1 Power :This OID gives the receive power value of the signal , read on the switch input 1 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Receive optical power on the RX1 of the OPS B " ::= { pmopsMesrComb 26 } --- ***************************************************** --- LEAF for the combRxPower2 article --- ***************************************************** pmopsMesrcombRxPower2 OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " RX2 Power :This OID gives the receive power value of the signal , read on the switch input 2 (Power=(AV-32768)*0.005) (Unit = dBm) This measure gives the Receive optical power on the RX2 of the OPS B " ::= { pmopsMesrComb 27 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group lsd --- ***************************************************** pmopsCfgLsd OBJECT IDENTIFIER ::= { pmopsConfig 1 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmopstablecomaLsd OBJECT IDENTIFIER ::= { pmopsCfgLsd 1 } --- ***************************************************** --- LEAF for the table Group startUp --- ***************************************************** pmopsCfgStartUp OBJECT IDENTIFIER ::= { pmopsConfig 2 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmopstablecomaStartup OBJECT IDENTIFIER ::= { pmopsCfgStartUp 1 } pmopsCfgcomaSwitchMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS A switch :This register configures the default switch mode on OPS A " ::= { pmopstablecomaStartup 2 } pmopsCfgcomaRxPwrSetting1 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS A Rx Pwr 1 :This register configures the default RX1 Loss threshold on the OPS A (Unit = dBm) " ::= { pmopstablecomaStartup 3 } pmopsCfgcomaRxPwrSetting2 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS A Rx Pwr 2 :This register configures the default RX2 Loss threshold on the OPS A (Unit = dBm) " ::= { pmopstablecomaStartup 4 } pmopsCfgcomaOosMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Setting on OPS A :This register configures the default modes on OPS A " ::= { pmopstablecomaStartup 5 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmopstablecombStartup OBJECT IDENTIFIER ::= { pmopsCfgStartUp 2 } pmopsCfgcombSwitchMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS B switch :This register configures the default switch mode on OPS B " ::= { pmopstablecombStartup 2 } pmopsCfgcombRxPwrSetting1 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS B Rx Pwr 1 :This register configures the default RX1 Loss threshold on the OPS B (Unit = dBm) " ::= { pmopstablecombStartup 3 } pmopsCfgcombRxPwrSetting2 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on OPS B Rx Pwr 2 :This register configures the default RX2 Loss threshold on the OPS B (Unit = dBm) " ::= { pmopstablecombStartup 4 } pmopsCfgcombOosMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Setting on OPS B :This register configures the default modes on OPS B " ::= { pmopstablecombStartup 5 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmopsCfgLabels OBJECT IDENTIFIER ::= { pmopsConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmopsCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF PmopsCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmopsCfgLabels 1 } pmopsCfgLabelclientEntry OBJECT-TYPE SYNTAX PmopsCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmopsCfgLabelclientIndex } ::= { pmopsCfgLabelclientTable 1 } PmopsCfgLabelclientEntry ::= SEQUENCE { pmopsCfgLabelclientIndex INTEGER, pmopsCfgLabelclientPortn DisplayString } pmopsCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmopsCfgLabelclientEntry 1 } pmopsCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmopsCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmopsCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF PmopsCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmopsCfgLabels 2 } pmopsCfgLabellineEntry OBJECT-TYPE SYNTAX PmopsCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmopsCfgLabellineIndex } ::= { pmopsCfgLabellineTable 1 } PmopsCfgLabellineEntry ::= SEQUENCE { pmopsCfgLabellineIndex INTEGER, pmopsCfgLabellinePortn DisplayString } pmopsCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmopsCfgLabellineEntry 1 } pmopsCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmopsCfgLabellineEntry 3 } pmopsCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmopsConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmopstrapPortNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last port which generates a trap" ::= { pmopstraps 2 } pmopstrapLineNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last Line which generates a trap" ::= { pmopstraps 3 } pmopstrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmopstraps 4 } --- ***************************************************** --- ComB TRAPS --- ***************************************************** pmopsComBTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmCombMeasWng, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmopsAlmCombMeasWng "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Warning appears on OPS B of PMOPS in slot $2 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pmopstraps 30 } pmopsComBTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmCombMeasWng, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS B Not Urgent ON"} --&MATCH { pmopsAlmCombMeasWng "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Warning disappears on OPS B of PMOPS in slot $2 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pmopstraps 31 } pmopsComBTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmCombMeasAlm, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Urgent ON" --&ACTIONS { log, major } --&MATCH { pmopsAlmCombMeasAlm "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Alarms appears on OPS B of PMOPS in slot $2 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pmopstraps 32 } pmopsComBTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmCombMeasAlm, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS B Urgent ON"} --&MATCH { pmopsAlmCombMeasAlm "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on OPS B of PMOPS in slot $2 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pmopstraps 33 } pmopsComBTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmCombFailAcc , pmopsAlmCombHwFailAcc, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Fail ON" --&ACTIONS { log, critical } --&MATCH { pmopsAlmCombFailAcc "on", pmopsAlmCombHwFailAcc "*", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm appears on OPS B of PMOPS in Slot $3 ($A)" --&FILTNAME "PMOPS B HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmopsAlmCombFailAcc "*", pmopsAlmCombHwFailAcc "on", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm appears on OPS B of PMOPS in Slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmopstraps 34 } pmopsComBTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmCombFailAcc , pmopsAlmCombHwFailAcc, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS B Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS B Fail ON" } --&MATCH { pmopsAlmCombFailAcc "on", pmopsAlmCombHwFailAcc "*", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm disappears on OPS B of PMOPS in Slot $3 ($A)" --&FILTNAME "PMOPS B HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmopsAlmCombFailAcc "*", pmopsAlmCombHwFailAcc "on", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm disappears on OPS B of PMOPS in Slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmopstraps 35 } --- ***************************************************** --- ComA TRAPS --- ***************************************************** pmopsComATrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmComaMeasWng, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmopsAlmComaMeasWng "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Warning appears on OPS A of PMOPS in slot $2 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pmopstraps 40 } pmopsComATrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmComaMeasWng, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS A Not Urgent ON"} --&MATCH { pmopsAlmComaMeasWng "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Warning disappears on OPS A of PMOPS in slot $2 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pmopstraps 41 } pmopsComATrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmComaMeasAlm, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Urgent ON" --&ACTIONS { log, major } --&MATCH { pmopsAlmComaMeasAlm "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Alarms appears on OPS A of PMOPS in slot $2 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pmopstraps 42 } pmopsComATrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmComaMeasAlm, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS A Urgent ON"} --&MATCH { pmopsAlmComaMeasAlm "on", pmopstrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on OPS A of PMOPS in slot $2 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pmopstraps 43 } pmopsComATrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmComaFailAcc, pmopsAlmComaHwFailAcc, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Fail ON" --&ACTIONS { log, critical } --&MATCH { pmopsAlmComaFailAcc "on", pmopsAlmComaHwFailAcc "*", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm appears on OPS A of PMOPS in Slot $3 ($A)" --&FILTNAME "PMOPS A HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmopsAlmComaFailAcc "*", pmopsAlmComaHwFailAcc "on", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm appears on OPS A of PMOPS in Slot $3 ($A)" DESCRIPTION "Critical client default is activated" ::= { pmopstraps 44 } pmopsComATrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmComaFailAcc, pmopsAlmComaHwFailAcc, pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS A Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PMOPS A Fail ON" } --&MATCH { pmopsAlmComaFailAcc "on", pmopsAlmComaHwFailAcc "*", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm disappears on OPS A of PMOPS in Slot $3 ($A)" --&FILTNAME "PMOPS A HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmopsAlmComaFailAcc "*", pmopsAlmComaHwFailAcc "on", pmopstrapBoardNumber "$3"} --&MESG "Critical alarm disappears on OPS A of PMOPS in Slot $3 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pmopstraps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmopsPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmopsAlmDefFuseB, pmopsAlmDefFuseA , pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmopsAlmDefFuseB "*", pmopsAlmDefFuseA "on", pmopstrapBoardNumber "$3"} --&MESG "Power Input A Fail on PMOPS in Slot $3 ($A)" --&FILTNAME "PMOPS Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmopsAlmDefFuseB "on", pmopsAlmDefFuseA "*", pmopstrapBoardNumber "$3"} --&MESG "Power Input B Fail on PMOPS in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmopstraps 50 } pmopsPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmopsAlmDefFuseB, pmopsAlmDefFuseA , pmopstrapBoardNumber} STATUS current --&FILTNAME "PMOPS Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMOPS Fuse A Fail ON", "PMOPS Fuse B Fail ON" } --&MATCH { pmopsAlmDefFuseB "on", pmopsAlmDefFuseA "on", pmopstrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMOPS in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmopstraps 51 } END