ACS8000-MIB DEFINITIONS ::= BEGIN -------------------------------------------------------------------------------- -- Avocent ACS8000 MIB -- Copyright 2017 Vertiv Co -- Revision: 2.0.2 -- Last Modified: October 2017 -------------------------------------------------------------------------------- IMPORTS Gauge,TimeTicks,IpAddress,Counter,NetworkAddress FROM RFC1155-SMI PhysAddress FROM RFC1213-MIB enterprises, MODULE-IDENTITY FROM SNMPv2-SMI OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, Integer32 FROM SNMPv2-SMI DisplayString FROM SNMPv2-TC InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB TRAP-TYPE FROM RFC-1215; -------------------------------------------------------------------------------- -- Object Groupings -------------------------------------------------------------------------------- --@ Note: every product type should be uniquely identified underneath the --@ acsProducts object group. Each product should report its unique acsProducts --@ OBJECT IDENTIFIER in mib-2.system.sysObjectID. -- enterprises .1.3.6.1.4.1 -- avocent OBJECT IDENTIFIER ::= { enterprises 10418 } acs MODULE-IDENTITY LAST-UPDATED "201711170000Z" ORGANIZATION "Vertiv Co" CONTACT-INFO "e-mail : support.avocent@vertivco.com Web : www.vertivco.com postal : Vertiv Co 4991 Corporate Drive Huntsville, AL 35805 USA" DESCRIPTION "This module defines the MIB extensions to ACS80xx products." REVISION "201711170000Z" DESCRIPTION "Vertiv updates" REVISION "201606170000Z" DESCRIPTION "Added UPS support" REVISION "201601060000Z" DESCRIPTION "Ported to acs8000 and that product list" REVISION "201010100000Z" DESCRIPTION "Extended acsPowerMgmt to support data monitoring and Avocent PM-PDUs" REVISION "200709170000Z" DESCRIPTION "First Draft" ::= { enterprises 10418 26 } acsProducts OBJECT IDENTIFIER ::= { acs 1 } acsManagement OBJECT IDENTIFIER ::= { acs 2 } -- acs8048 OBJECT IDENTIFIER ::= { acsProducts 1 } -- 10418.26.1.1 acs8032 OBJECT IDENTIFIER ::= { acsProducts 2 } -- 10418.26.1.2 acs8016 OBJECT IDENTIFIER ::= { acsProducts 3 } -- 10418.26.1.3 acs8008 OBJECT IDENTIFIER ::= { acsProducts 4 } -- 10418.26.1.4 acs808 OBJECT IDENTIFIER ::= { acsProducts 5 } -- 10418.26.1.5 acs804 OBJECT IDENTIFIER ::= { acsProducts 6 } -- 10418.26.1.6 acs802 OBJECT IDENTIFIER ::= { acsProducts 7 } -- 10418.26.1.7 acsAppliance OBJECT IDENTIFIER ::= { acsManagement 1 } -- 10418.26.2.1 acsSessions OBJECT IDENTIFIER ::= { acsManagement 2 } -- 10418.26.2.2 acsSerialPort OBJECT IDENTIFIER ::= { acsManagement 3 } -- 10418.26.2.3 acsPowerMgmt OBJECT IDENTIFIER ::= { acsManagement 5 } -- 10418.26.2.5 -- objects under acsPowerMgmt -- acsPowerMgmtNumSerialPorts ::= { acsPowerMgmt 1 } -- acsPowerMgmtSerialTable ::= { acsPowerMgmt 2 } -- acsPowerMgmtPDUTable ::= { acsPowerMgmt 3 } -- acsPowerMgmtTotalNumberOfOutlets ::= { acsPowerMgmt 4 } -- acsPowerMgmtOutletsTable ::= { acsPowerMgmt 5 } -- acsPowerMgmtNumberOfOutletGroup ::= { acsPowerMgmt 6 } -- acsPowerMgmtGroupTable ::= { acsPowerMgmt 7 } -- acsPowerMgmtPhasesTable ::= { acsPowerMgmt 8 } -- acsPowerMgmtBanksTable ::= { acsPowerMgmt 9 } -- acsPowerMgmtEnvMonTable ::= { acsPowerMgmt 10 } -- acsPowerMgmtOutElecMonTable ::= { acsPowerMgmt 11 } -- acsPowerMgmtUPSTable ::= { acsPowerMgmt 12 } -- acsPowerMgmtUPSInputTable ::= { acsPowerMgmt 13 } -- acsPowerMgmtUPSBypassTable ::= { acsPowerMgmt 14 } -- acsPowerMgmtUPSBatteryTable ::= { acsPowerMgmt 15 } -- acsPowerMgmtUPSOutputTable ::= { acsPowerMgmt 16 } -- acsPowerMgmtUPSEcoModeTable ::= { acsPowerMgmt 17 } -- acsPowerMgmtUPSOutletGroupTable ::= { acsPowerMgmt 18 } -- -- Note that traps are defined in a separate trap MIB -- acsTrapObject OBJECT IDENTIFIER ::= { acsManagement 6 } -- 10418.26.2.6 -- -- Type Definitions -- -- -- Each enumeration represents the states of the appliance power supplies. PowerSupplyState ::= INTEGER { statePowerOn(1), statePowerOff(2), powerNotInstaled(9999) } -- -- Each enumeration represents the speed of the serial port. SerialPortSpeed ::= INTEGER { speed300bps(300), speed600bps(600), speed1200bps(1200), speed2400bps(2400), speed4800bps(4800), speed9600bps(9600), speed19200bps(19200), speed38400bps(38400), speed57600bps(57600), speed115200bps(115200), speed230400bps(230400), speed460800bps(460800) } -- -- Each enumeration represents the state of the RS-232C signal. SerialPortSignalState ::=INTEGER { up(1), down(2) } -- -- Each enumeration represents the RJ-45 pin-out SerialPortPinOut ::=INTEGER { cyclades(1), cisco(2), rs422(3), rs485(4), auto(5) } -- -- acsAppliance -- OBJECT IDENTIFIER ::= { acsManagement 1 } 10418.26.2.1 -- acsHostName OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The appliance name" ::= { acsAppliance 1 } acsProductModel OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..50) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The appliance product model" ::= { acsAppliance 2 } acsPartNumber OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The part number of this appliance as shown on the label attached or imprinted on the appliance." ::= { acsAppliance 3 } acsSerialNumber OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The serial number of this appliance as shown on the label attached or imprinted on the appliance." ::= { acsAppliance 4 } acsEIDNumber OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance." ::= { acsAppliance 5 } acsBootcodeVersion OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the bootcode of this appliance." ::= { acsAppliance 6 } acsFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the firmware of this appliance." ::= { acsAppliance 7 } acsPowerSupply OBJECT-IDENTITY STATUS current DESCRIPTION "It gives information about Power Supply of this appliance" ::= { acsAppliance 8 } acsPowerSupplyNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the power supplies of this appliance" ::= { acsPowerSupply 1 } acsPowerSupplyStatePw1 OBJECT-TYPE SYNTAX PowerSupplyState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the first power supply" ::= { acsPowerSupply 2 } acsPowerSupplyStatePw2 OBJECT-TYPE SYNTAX PowerSupplyState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the second power supply" ::= { acsPowerSupply 3 } acsReboot OBJECT-TYPE SYNTAX INTEGER { noAction(1), reboot(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately reboots." ::= { acsAppliance 9 } -- -- acsSessions -- OBJECT IDENTIFIER ::= { acsManagement 2 } 10418.26.2.2 -- acsActiveSessionsNumberOfSession OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of active sessions." ::= { acsSessions 1 } acsActiveSessionsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsActiveSessionsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the list of active sessions." ::= { acsSessions 2 } acsActiveSessionsTableEntry OBJECT-TYPE SYNTAX AcsActiveSessionsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the active session" INDEX { acsActiveSessionsTableIndex } ::= { acsActiveSessionsTable 1 } AcsActiveSessionsTableEntry ::= SEQUENCE { acsActiveSessionsTableIndex InterfaceIndexOrZero, acsActiveSessionsTableUser DisplayString, -- user name acsActiveSessionsTableGroup DisplayString, -- group name acsActiveSessionsTableType DisplayString, -- RO/RW-ssh,telnet or web acsActiveSessionsTableConnection DisplayString, -- type + target name acsActiveSessionsTableSessionTime DisplayString, -- time of session acsActiveSessionsTableFrom DisplayString, -- source of the session acsActiveSessionsTableKill INTEGER } acsActiveSessionsTableIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A unique index representing an entry in this table." ::= { acsActiveSessionsTableEntry 1 } acsActiveSessionsTableUser OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the user that opens this session." ::= { acsActiveSessionsTableEntry 2 } acsActiveSessionsTableGroup OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the group that the user belongs to." ::= { acsActiveSessionsTableEntry 3 } acsActiveSessionsTableType OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The session type." ::= { acsActiveSessionsTableEntry 4 } acsActiveSessionsTableConnection OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Connection type." ::= { acsActiveSessionsTableEntry 5 } acsActiveSessionsTableSessionTime OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "Time of the session" ::= { acsActiveSessionsTableEntry 6 } acsActiveSessionsTableFrom OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..32) ) MAX-ACCESS read-only STATUS current DESCRIPTION "The source IP address of the session." ::= { acsActiveSessionsTableEntry 7 } acsActiveSessionsTableKill OBJECT-TYPE SYNTAX INTEGER { noAction(1), killSession(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immediately kills the session." ::= { acsActiveSessionsTableEntry 8 } -- -- acsSerialPort -- OBJECT IDENTIFIER ::= { acsManagement 3 } 10418.26.2.3 -- acsSerialPortNumberOfPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Serial Ports (physical serial port plus Aux Port." ::= { acsSerialPort 1 } acsSerialPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsSerialPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about serial ports." ::= { acsSerialPort 2 } acsSerialPortTableEntry OBJECT-TYPE SYNTAX AcsSerialPortTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about specific serial port." INDEX { acsSerialPortTableNumber } ::= { acsSerialPortTable 1 } AcsSerialPortTableEntry ::= SEQUENCE { acsSerialPortTableNumber Integer32, -- serial port number acsSerialPortTableDeviceName DisplayString, -- associated device name acsSerialPortTableStatus INTEGER, -- status of serial port acsSerialPortTableName DisplayString, -- associated name acsSerialPortTableProfile INTEGER, -- configured profile acsSerialPortTablePinOut SerialPortPinOut, -- configure RJ45 pin-out acsSerialPortTableComSpeed SerialPortSpeed, -- configured speed acsSerialPortTableComParity INTEGER, -- configured parity acsSerialPortTableComDataSize Integer32, -- configured data size acsSerialPortTableComStopBits Integer32, -- configured stop bits acsSerialPortTableComFlowControl INTEGER, -- configured flow control acsSerialPortTableSignalStateDTR SerialPortSignalState, -- state of DTR RS-232C signal acsSerialPortTableSignalStateDCD SerialPortSignalState, -- state of DCD RS-232C signal acsSerialPortTableSignalStateRTS SerialPortSignalState, -- state of RTS RS-232C signal acsSerialPortTableSignalStateCTS SerialPortSignalState, -- state of CTS RS-232C signal acsSerialPortTableTxBytes Integer32, -- number of transmitted bytes acsSerialPortTableRxBytes Integer32, -- number of received bytes acsSerialPortTableFrameError Integer32, -- number of detected frame errors acsSerialPortTableParityError Integer32, -- number of detected parity errors acsSerialPortTableBreak Integer32, -- number of detected break acsSerialPortTableOverrun Integer32 -- number of detected overrun errors } acsSerialPortTableNumber OBJECT-TYPE SYNTAX Integer32 (1..49) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique index representing an entry in this table. It is the number of the serial port. For AUX port, the number will be the number of physical serial ports plus 1." ::= { acsSerialPortTableEntry 1 } acsSerialPortTableDeviceName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-only STATUS current DESCRIPTION "The associated device name for the serial port." ::= { acsSerialPortTableEntry 2 } acsSerialPortTableStatus OBJECT-TYPE SYNTAX INTEGER { disabled(1), idle(2), inUse(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the serial port: disabled(1) = it was configured as disable. idle(2) = there is not any session opened in this port. inUse(3) = there is session(s) opened in this port." ::= { acsSerialPortTableEntry 3 } acsSerialPortTableName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) MAX-ACCESS read-only STATUS current DESCRIPTION "Name associated with this serial port." ::= { acsSerialPortTableEntry 4 } acsSerialPortTableProfile OBJECT-TYPE SYNTAX INTEGER { casProfile(1), tsProfile(2), dialInProfile(3), powerProfile(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Configured profile for this serial port." ::= { acsSerialPortTableEntry 5 } acsSerialPortTablePinOut OBJECT-TYPE SYNTAX SerialPortPinOut MAX-ACCESS read-only STATUS current DESCRIPTION "RJ45 Pin-out configured for this serial port." ::= { acsSerialPortTableEntry 6 } acsSerialPortTableComSpeed OBJECT-TYPE SYNTAX SerialPortSpeed MAX-ACCESS read-only STATUS current DESCRIPTION "Speed configured for this serial port." ::= { acsSerialPortTableEntry 7 } acsSerialPortTableComParity OBJECT-TYPE SYNTAX INTEGER { none(1), odd(2), even(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Parity configured for this serial port." ::= { acsSerialPortTableEntry 8 } acsSerialPortTableComDataSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Data Size configured for this serial port." ::= { acsSerialPortTableEntry 9 } acsSerialPortTableComStopBits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Stop Bits configured for this serial port." ::= { acsSerialPortTableEntry 10 } acsSerialPortTableComFlowControl OBJECT-TYPE SYNTAX INTEGER { none(1), hardware(2), software(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flow Control configured for this serial port." ::= { acsSerialPortTableEntry 11 } acsSerialPortTableSignalStateDTR OBJECT-TYPE SYNTAX SerialPortSignalState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the DTR RS-232C signal." ::= { acsSerialPortTableEntry 12 } acsSerialPortTableSignalStateDCD OBJECT-TYPE SYNTAX SerialPortSignalState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the DCD RS-232C signal." ::= { acsSerialPortTableEntry 13 } acsSerialPortTableSignalStateRTS OBJECT-TYPE SYNTAX SerialPortSignalState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the RTS RS-232C signal." ::= { acsSerialPortTableEntry 14 } acsSerialPortTableSignalStateCTS OBJECT-TYPE SYNTAX SerialPortSignalState MAX-ACCESS read-only STATUS current DESCRIPTION "State of the CTS RS-232C signal." ::= { acsSerialPortTableEntry 15 } acsSerialPortTableTxBytes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmited bytes by the serial port." ::= { acsSerialPortTableEntry 16 } acsSerialPortTableRxBytes OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received bytes by the serial port." ::= { acsSerialPortTableEntry 17 } acsSerialPortTableFrameError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frame error detected in the serial port." ::= { acsSerialPortTableEntry 18 } acsSerialPortTableParityError OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of parity error detected in the serial port." ::= { acsSerialPortTableEntry 19 } acsSerialPortTableBreak OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of break detected in the serial port." ::= { acsSerialPortTableEntry 20 } acsSerialPortTableOverrun OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of overrun error detected in the serial port." ::= { acsSerialPortTableEntry 21 } -- -- acsPowerMgmt -- OBJECT IDENTIFIER ::= { acsManagement 5 } 10418.26.2.5 -- acsPowerMgmtNumSerialPorts OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Serial Ports that has PDU connected on the appliance." ::= { acsPowerMgmt 1 } acsPowerMgmtSerialTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtSerialTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about each serial port thas has PDU connect." ::= { acsPowerMgmt 2 } acsPowerMgmtSerialTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtSerialTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about each serial port thas has PDU connect." INDEX { acsPowerMgmtSerialTableIndex } ::= { acsPowerMgmtSerialTable 1 } AcsPowerMgmtSerialTableEntry ::= SEQUENCE { acsPowerMgmtSerialTableIndex InterfaceIndex, acsPowerMgmtSerialTablePortNumber Integer32, acsPowerMgmtSerialTableDeviceName DisplayString, acsPowerMgmtSerialTableNumberPDUs Integer32, acsPowerMgmtSerialTableNumberUPS Integer32 } acsPowerMgmtSerialTableIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the register." ::= { acsPowerMgmtSerialTableEntry 1 } acsPowerMgmtSerialTablePortNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of the serial port when the PDU is connected." ::= { acsPowerMgmtSerialTableEntry 2 } acsPowerMgmtSerialTableDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The device name of this serial port." ::= { acsPowerMgmtSerialTableEntry 3 } acsPowerMgmtSerialTableNumberPDUs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of units connected in this serial port." ::= { acsPowerMgmtSerialTableEntry 4 } acsPowerMgmtSerialTableNumberUPS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total number of UPS devices connected to this serial port." ::= { acsPowerMgmtSerialTableEntry 5 } acsPowerMgmtPDUTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtPDUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the list of detected PDUs." ::= { acsPowerMgmt 3 } acsPowerMgmtPDUTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtPDUTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the PDU." INDEX { acsPowerMgmtPDUTablePortNumber, acsPowerMgmtPDUTablePduIndex } ::= { acsPowerMgmtPDUTable 1 } AcsPowerMgmtPDUTableEntry ::= SEQUENCE { acsPowerMgmtPDUTablePortNumber InterfaceIndex, -- number of serial port acsPowerMgmtPDUTablePduIndex InterfaceIndexOrZero, acsPowerMgmtPDUTablePduId DisplayString, -- PDU identification acsPowerMgmtPDUTablePortName DisplayString, -- Serial Port Name acsPowerMgmtPDUTableModel DisplayString, -- PDU model acsPowerMgmtPDUTableVendor DisplayString, -- Vendor acsPowerMgmtPDUTableFirmwareVersion DisplayString, -- Firmware Version acsPowerMgmtPDUTableNumberOfOutlets Integer32, acsPowerMgmtPDUTableCurrentNOS Integer32, -- OBSOLETED number of current sensors acsPowerMgmtPDUTableCurrent1Value Integer32, -- OBSOLETED actual value for current of the sensor 1 acsPowerMgmtPDUTableCurrent1Max Integer32, -- OBSOLETED max value for current of the sensor 1 acsPowerMgmtPDUTableCurrent2Value Integer32, -- OBSOLETED actual value for current of the sensor 2 acsPowerMgmtPDUTableCurrent2Max Integer32, -- OBSOLETED max value for current of the sensor 2 acsPowerMgmtPDUTableCurrent3Value Integer32, -- OBSOLETED actual value for current of the sensor 3 acsPowerMgmtPDUTableCurrent3Max Integer32, -- OBSOLETED max value for current of the sensor 3 acsPowerMgmtPDUTableTemperatureNOS Integer32, -- OBSOLETED number of temperature sensors acsPowerMgmtPDUTableTemperature1Value Integer32, -- OBSOLETED actual value for Temperature 1 acsPowerMgmtPDUTableTemperature1Max Integer32, -- OBSOLETED max value for Temperature 1 acsPowerMgmtPDUTableTemperature2Value Integer32, -- OBSOLETED actual value for Temperaturet 2 acsPowerMgmtPDUTableTemperature2Max Integer32, -- OBSOLETED max value for Temperature 2 acsPowerMgmtPDUTableTemperature3Value Integer32, -- OBSOLETED actual value for Temperature 3 acsPowerMgmtPDUTableTemperature3Max Integer32, -- OBSOLETED max value for Temperature 3 acsPowerMgmtPDUTableHumidityNOS Integer32, -- OBSOLETED humidity number of humidity sensors acsPowerMgmtPDUTableHumidity1Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 1 acsPowerMgmtPDUTableHumidity1Max Integer32, -- OBSOLETED max value for Humidityof the sensor 1 acsPowerMgmtPDUTableHumidity2Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 2 acsPowerMgmtPDUTableHumidity2Max Integer32, -- OBSOLETED max value for Humidity of the sensor 2 acsPowerMgmtPDUTableHumidity3Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 3 acsPowerMgmtPDUTableHumidity3Max Integer32, -- OBSOLETED max value for Humidity of the sensor 3 acsPowerMgmtPDUTableVoltageNOS Integer32, -- OBSOLETED number of voltage sensor acsPowerMgmtPDUTableVoltage1Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 1 acsPowerMgmtPDUTableVoltage1Max Integer32, -- OBSOLETED max value for Voltage of the sensor 1 acsPowerMgmtPDUTableVoltage2Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 2 acsPowerMgmtPDUTableVoltage2Max Integer32, -- OBSOLETED max value for Voltaget of the sensor 2 acsPowerMgmtPDUTableVoltage3Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 3 acsPowerMgmtPDUTableVoltage3Max Integer32, -- OBSOLETED max value for Voltage of the sensor 3 acsPowerMgmtPDUTableNumberOfPhases Integer32, -- number of phases (single or 3-phases) acsPowerMgmtPDUTableNumberOfBanks Integer32, -- number of banks acsPowerMgmtPDUTableCurrentValue Integer32, -- actual value of PDU current sensor acsPowerMgmtPDUTableCurrentMax Integer32, -- max detected value of current sensor acsPowerMgmtPDUTableCurrentMin Integer32, -- min detected value of current sensor acsPowerMgmtPDUTableCurrentAvg Integer32, -- average value for current sensor acsPowerMgmtPDUTableCurrentReset INTEGER, -- reset max, min and avg values acsPowerMgmtPDUTableVoltageType INTEGER, -- type of PDU voltage acsPowerMgmtPDUTableVoltageValue Integer32, -- actual value of PDU voltage acsPowerMgmtPDUTableVoltageMax Integer32, -- max value of voltage sensor acsPowerMgmtPDUTableVoltageMin Integer32, -- min value of voltage sensor acsPowerMgmtPDUTableVoltageAvg Integer32, -- avg value of voltage sensor acsPowerMgmtPDUTableVoltageReset INTEGER, -- reset max, min and avg values acsPowerMgmtPDUTablePowerType INTEGER, -- type of PDU power consumption acsPowerMgmtPDUTablePowerValue Integer32, -- actual value of PDU power consumption acsPowerMgmtPDUTablePowerMax Integer32, -- max value acsPowerMgmtPDUTablePowerMin Integer32, -- min value acsPowerMgmtPDUTablePowerAvg Integer32, -- average value acsPowerMgmtPDUTablePowerReset INTEGER, -- reset max, min and avg values acsPowerMgmtPDUTablePowerFactorType INTEGER, -- type of PDU power factor acsPowerMgmtPDUTablePowerFactorValue Integer32, -- actual value of PDU power factor acsPowerMgmtPDUTablePowerFactorMax Integer32, -- max value for power factor acsPowerMgmtPDUTablePowerFactorMin Integer32, -- min value for power factor acsPowerMgmtPDUTablePowerFactorAvg Integer32, -- avg value for power factor acsPowerMgmtPDUTablePowerFactorReset INTEGER, -- reset max, min and avg values acsPowerMgmtPDUTableAlarm INTEGER, -- status of PDU alarm acsPowerMgmtPDUTableEnvSensors Integer32 -- number of environmental sensors } acsPowerMgmtPDUTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of serial port when the PDU is connected." ::= { acsPowerMgmtPDUTableEntry 1 } acsPowerMgmtPDUTablePduIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A PDU position in the chain." ::= { acsPowerMgmtPDUTableEntry 2 } acsPowerMgmtPDUTablePduId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PDU identification." ::= { acsPowerMgmtPDUTableEntry 3 } acsPowerMgmtPDUTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of serial port when the PDU is connected." ::= { acsPowerMgmtPDUTableEntry 4 } acsPowerMgmtPDUTableModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Model of the PDU." ::= { acsPowerMgmtPDUTableEntry 5 } acsPowerMgmtPDUTableVendor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor of the PDU." ::= { acsPowerMgmtPDUTableEntry 6 } acsPowerMgmtPDUTableFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version of the PDU firmware." ::= { acsPowerMgmtPDUTableEntry 7 } acsPowerMgmtPDUTableNumberOfOutlets OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of outlets of the PDU." ::= { acsPowerMgmtPDUTableEntry 8 } acsPowerMgmtPDUTableCurrentNOS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Number of current sensors in the PDU." ::= { acsPowerMgmtPDUTableEntry 9 } acsPowerMgmtPDUTableCurrent1Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Current of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)" ::= { acsPowerMgmtPDUTableEntry 10 } acsPowerMgmtPDUTableCurrent1Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value." ::= { acsPowerMgmtPDUTableEntry 11 } acsPowerMgmtPDUTableCurrent2Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Current of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)" ::= { acsPowerMgmtPDUTableEntry 12 } acsPowerMgmtPDUTableCurrent2Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value." ::= { acsPowerMgmtPDUTableEntry 13} acsPowerMgmtPDUTableCurrent3Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Current of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)" ::= { acsPowerMgmtPDUTableEntry 14 } acsPowerMgmtPDUTableCurrent3Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value." ::= { acsPowerMgmtPDUTableEntry 15 } acsPowerMgmtPDUTableTemperatureNOS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Number of temperature sensors in the PDU." ::= { acsPowerMgmtPDUTableEntry 16 } acsPowerMgmtPDUTableTemperature1Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." ::= { acsPowerMgmtPDUTableEntry 17 } acsPowerMgmtPDUTableTemperature1Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 18 } acsPowerMgmtPDUTableTemperature2Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." ::= { acsPowerMgmtPDUTableEntry 19 } acsPowerMgmtPDUTableTemperature2Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 20 } acsPowerMgmtPDUTableTemperature3Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Temperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)." ::= { acsPowerMgmtPDUTableEntry 21 } acsPowerMgmtPDUTableTemperature3Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 22 } acsPowerMgmtPDUTableHumidityNOS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Number of humidity sensors in the PDU." ::= { acsPowerMgmtPDUTableEntry 23 } acsPowerMgmtPDUTableHumidity1Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Humidity of this PM unit . If the humidity measurement is not installed this value will be 0." ::= { acsPowerMgmtPDUTableEntry 24 } acsPowerMgmtPDUTableHumidity1Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 25 } acsPowerMgmtPDUTableHumidity2Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Humidity of this PM unit . If the humidity measurement is not installed this value will be 0." ::= { acsPowerMgmtPDUTableEntry 26 } acsPowerMgmtPDUTableHumidity2Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 27 } acsPowerMgmtPDUTableHumidity3Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Humidity of this PM unit . If the humidity measurement is not installed this value will be 0." ::= { acsPowerMgmtPDUTableEntry 28 } acsPowerMgmtPDUTableHumidity3Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature." ::= { acsPowerMgmtPDUTableEntry 29 } acsPowerMgmtPDUTableVoltageNOS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Number of voltage sensors in the PDU." ::= { acsPowerMgmtPDUTableEntry 30 } acsPowerMgmtPDUTableVoltage1Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Voltage of this sensor in this PDU unit." ::= { acsPowerMgmtPDUTableEntry 31 } acsPowerMgmtPDUTableVoltage1Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage." ::= { acsPowerMgmtPDUTableEntry 32 } acsPowerMgmtPDUTableVoltage2Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Voltage of this sensor in this PDU unit." ::= { acsPowerMgmtPDUTableEntry 33 } acsPowerMgmtPDUTableVoltage2Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage." ::= { acsPowerMgmtPDUTableEntry 34 } acsPowerMgmtPDUTableVoltage3Value OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Voltage of this sensor in this PDU unit." ::= { acsPowerMgmtPDUTableEntry 35 } acsPowerMgmtPDUTableVoltage3Max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Maximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage." ::= { acsPowerMgmtPDUTableEntry 36 } acsPowerMgmtPDUTableNumberOfPhases OBJECT-TYPE SYNTAX INTEGER { single-phase (0), three-phase (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Number of phases of this PDU unit." ::= { acsPowerMgmtPDUTableEntry 37 } acsPowerMgmtPDUTableNumberOfBanks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of banks of this PDU unit." ::= { acsPowerMgmtPDUTableEntry 38 } acsPowerMgmtPDUTableCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of current sensor in this PDU.( A x 10 )" ::= { acsPowerMgmtPDUTableEntry 39 } acsPowerMgmtPDUTableCurrentMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of current sensor in this PDU.( A x 10 )" ::= { acsPowerMgmtPDUTableEntry 40 } acsPowerMgmtPDUTableCurrentMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of current sensor in this PDU.( A x 10 )" ::= { acsPowerMgmtPDUTableEntry 41 } acsPowerMgmtPDUTableCurrentAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for current sensor in this PDU.( A x 10 )" ::= { acsPowerMgmtPDUTableEntry 42 } acsPowerMgmtPDUTableCurrentReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of current." ::= { acsPowerMgmtPDUTableEntry 43 } acsPowerMgmtPDUTableVoltageType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of voltage values." ::= { acsPowerMgmtPDUTableEntry 44 } acsPowerMgmtPDUTableVoltageValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of voltage sensor in this PDU unit.( V )" ::= { acsPowerMgmtPDUTableEntry 45 } acsPowerMgmtPDUTableVoltageMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of voltage sensor in this PDU unit.( V )" ::= { acsPowerMgmtPDUTableEntry 46 } acsPowerMgmtPDUTableVoltageMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of voltage sensor in this PDU unit.( V )" ::= { acsPowerMgmtPDUTableEntry 47 } acsPowerMgmtPDUTableVoltageAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for voltage sensor in this PDU unit.( V )" ::= { acsPowerMgmtPDUTableEntry 48 } acsPowerMgmtPDUTableVoltageReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of voltage." ::= { acsPowerMgmtPDUTableEntry 49 } acsPowerMgmtPDUTablePowerType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power consumption values.( W x 10 )" ::= { acsPowerMgmtPDUTableEntry 50 } acsPowerMgmtPDUTablePowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power consumption in this PDU unit.( W x 10 )" ::= { acsPowerMgmtPDUTableEntry 51 } acsPowerMgmtPDUTablePowerMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power consumption in this PDU unit.( W x 10 )" ::= { acsPowerMgmtPDUTableEntry 52 } acsPowerMgmtPDUTablePowerMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power consumption in this PDU unit.( W x 10 )" ::= { acsPowerMgmtPDUTableEntry 53 } acsPowerMgmtPDUTablePowerAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power consumption in this PDU unit.( W x 10 )" ::= { acsPowerMgmtPDUTableEntry 54 } acsPowerMgmtPDUTablePowerReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power consumption." ::= { acsPowerMgmtPDUTableEntry 55 } acsPowerMgmtPDUTablePowerFactorType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power factor values." ::= { acsPowerMgmtPDUTableEntry 56 } acsPowerMgmtPDUTablePowerFactorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power factor in this PDU unit.( PF x 100 )" ::= { acsPowerMgmtPDUTableEntry 57 } acsPowerMgmtPDUTablePowerFactorMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power factor in this PDU unit.( PF x 100 )" ::= { acsPowerMgmtPDUTableEntry 58 } acsPowerMgmtPDUTablePowerFactorMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power factor in this PDU unit.( PF x 100 )" ::= { acsPowerMgmtPDUTableEntry 59 } acsPowerMgmtPDUTablePowerFactorAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power factor in this PDU unit.( PF x 100 )" ::= { acsPowerMgmtPDUTableEntry 60 } acsPowerMgmtPDUTablePowerFactorReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power factor." ::= { acsPowerMgmtPDUTableEntry 61 } acsPowerMgmtPDUTableAlarm OBJECT-TYPE SYNTAX INTEGER { normal (1), blow-fuse (2), hw-ocp (3), high-critical (4), high-warning (5), low-warning (6), low-critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show the PDU alarm status." ::= { acsPowerMgmtPDUTableEntry 62 } acsPowerMgmtPDUTableEnvSensors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of environmental sensor in this PDU." ::= { acsPowerMgmtPDUTableEntry 63 } acsPowerMgmtTotalNumberOfOutlets OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of outlets managed by the appliance." ::= { acsPowerMgmt 4 } acsPowerMgmtOutletsTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtOutletsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about outlets." ::= { acsPowerMgmt 5 } acsPowerMgmtOutletsTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtOutletsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the outlet." INDEX { acsPowerMgmtOutletsTablePortNumber, acsPowerMgmtOutletsTablePduNumber, acsPowerMgmtOutletsTableNumber } ::= { acsPowerMgmtOutletsTable 1 } AcsPowerMgmtOutletsTableEntry ::= SEQUENCE { acsPowerMgmtOutletsTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtOutletsTablePduNumber InterfaceIndex, acsPowerMgmtOutletsTableNumber InterfaceIndex, -- outlet number in PDU acsPowerMgmtOutletsTableName DisplayString, -- outlet name acsPowerMgmtOutletsTableStatus INTEGER, -- outlet status acsPowerMgmtOutletsTablePowerControl INTEGER, -- manage the outlet acsPowerMgmtOutletsTablePortName DisplayString, -- serial port name acsPowerMgmtOutletsTablePduId DisplayString -- PDU ID } acsPowerMgmtOutletsTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtOutletsTableEntry 1 } acsPowerMgmtOutletsTablePduNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtOutletsTableEntry 2 } acsPowerMgmtOutletsTableNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the outlet in the PDU." ::= { acsPowerMgmtOutletsTableEntry 3 } acsPowerMgmtOutletsTableName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the outlet." ::= { acsPowerMgmtOutletsTableEntry 4 } acsPowerMgmtOutletsTableStatus OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the outlet." ::= { acsPowerMgmtOutletsTableEntry 5 } acsPowerMgmtOutletsTablePowerControl OBJECT-TYPE SYNTAX INTEGER { noAction(1), powerOn(2), powerOff(3), powerCycle(4), powerLock(5), powerUnlock(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUs" ::= { acsPowerMgmtOutletsTableEntry 6 } acsPowerMgmtOutletsTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port Name where the PDU is connected." ::= { acsPowerMgmtOutletsTableEntry 7 } acsPowerMgmtOutletsTablePduId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PDU identification." ::= { acsPowerMgmtOutletsTableEntry 8 } acsPowerMgmtNumberOfOutletGroup OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of configured group of outlets." ::= { acsPowerMgmt 6 } acsPowerMgmtGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtGroupTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about group of outlets." ::= { acsPowerMgmt 7 } acsPowerMgmtGroupTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtGroupTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about group of outlets." INDEX { acsPowerMgmtGroupTableIndex } ::= { acsPowerMgmtGroupTable 1 } AcsPowerMgmtGroupTableEntry ::= SEQUENCE { acsPowerMgmtGroupTableIndex InterfaceIndexOrZero, acsPowerMgmtGroupTableName DisplayString, -- group name acsPowerMgmtGroupTableStatus INTEGER, -- group status acsPowerMgmtGroupTablePowerControl INTEGER -- manage the group } acsPowerMgmtGroupTableIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "Index of the group." ::= { acsPowerMgmtGroupTableEntry 1 } acsPowerMgmtGroupTableName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of the group of outlets." ::= { acsPowerMgmtGroupTableEntry 2 } acsPowerMgmtGroupTableStatus OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of the group of outlet." ::= { acsPowerMgmtGroupTableEntry 3 } acsPowerMgmtGroupTablePowerControl OBJECT-TYPE SYNTAX INTEGER { noAction(1), powerOn(2), powerOff(3), powerCycle(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU." ::= { acsPowerMgmtGroupTableEntry 4 } acsPowerMgmtPhasesTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtPhasesTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data monitoring of each detected phase." ::= { acsPowerMgmt 8 } acsPowerMgmtPhasesTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtPhasesTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the data monitoring about phases." INDEX { acsPowerMgmtPhasesTablePortNumber, acsPowerMgmtPhasesTablePduIndex, acsPowerMgmtPhasesTablePhaseIndex } ::= { acsPowerMgmtPhasesTable 1 } AcsPowerMgmtPhasesTableEntry ::= SEQUENCE { acsPowerMgmtPhasesTablePortNumber InterfaceIndex, -- number of serial port acsPowerMgmtPhasesTablePduIndex InterfaceIndexOrZero, -- number of PDU acsPowerMgmtPhasesTablePhaseIndex InterfaceIndexOrZero, -- phase index acsPowerMgmtPhasesTablePhaseName DisplayString, -- Phase Name acsPowerMgmtPhasesTablePduId DisplayString, -- PDU identification acsPowerMgmtPhasesTablePortName DisplayString, -- Serial Port Name acsPowerMgmtPhasesTableCurrentValue Integer32, -- actual value of Phase current sensor acsPowerMgmtPhasesTableCurrentMax Integer32, -- max detected value of current sensor acsPowerMgmtPhasesTableCurrentMin Integer32, -- min detected value of current sensor acsPowerMgmtPhasesTableCurrentAvg Integer32, -- average value for current sensor acsPowerMgmtPhasesTableCurrentReset INTEGER, -- reset max, min and avg values acsPowerMgmtPhasesTableVoltageType INTEGER, -- type of phase voltage acsPowerMgmtPhasesTableVoltageValue Integer32, -- actual value of phase voltage acsPowerMgmtPhasesTableVoltageMax Integer32, -- max value of voltage sensor acsPowerMgmtPhasesTableVoltageMin Integer32, -- min value of voltage sensor acsPowerMgmtPhasesTableVoltageAvg Integer32, -- avg value of voltage sensor acsPowerMgmtPhasesTableVoltageReset INTEGER, -- reset max, min and avg values acsPowerMgmtPhasesTablePowerType INTEGER, -- type of phase power consumption acsPowerMgmtPhasesTablePowerValue Integer32, -- actual value of phase power consumption acsPowerMgmtPhasesTablePowerMax Integer32, -- max value acsPowerMgmtPhasesTablePowerMin Integer32, -- min value acsPowerMgmtPhasesTablePowerAvg Integer32, -- average value acsPowerMgmtPhasesTablePowerReset INTEGER, -- reset max, min and avg values acsPowerMgmtPhasesTablePowerFactorType INTEGER, -- type of phase power factor acsPowerMgmtPhasesTablePowerFactorValue Integer32, -- actual value of phase power factor acsPowerMgmtPhasesTablePowerFactorMax Integer32, -- max value for power factor acsPowerMgmtPhasesTablePowerFactorMin Integer32, -- min value for power factor acsPowerMgmtPhasesTablePowerFactorAvg Integer32, -- avg value for power factor acsPowerMgmtPhasesTablePowerFactorReset INTEGER, -- reset max, min and avg values acsPowerMgmtPhasesTableAlarm INTEGER -- phase alarm status } acsPowerMgmtPhasesTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of serial port when the PDU is connected." ::= { acsPowerMgmtPhasesTableEntry 1 } acsPowerMgmtPhasesTablePduIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A PDU position in the chain." ::= { acsPowerMgmtPhasesTableEntry 2 } acsPowerMgmtPhasesTablePhaseIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "phase index in the PDU." ::= { acsPowerMgmtPhasesTableEntry 3 } acsPowerMgmtPhasesTablePhaseName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "phase name in the PDU." ::= { acsPowerMgmtPhasesTableEntry 4 } acsPowerMgmtPhasesTablePduId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PDU identification." ::= { acsPowerMgmtPhasesTableEntry 5 } acsPowerMgmtPhasesTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of serial port when the PDU is connected." ::= { acsPowerMgmtPhasesTableEntry 6 } acsPowerMgmtPhasesTableCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of current sensor in this phase.( A x 10 )" ::= { acsPowerMgmtPhasesTableEntry 7 } acsPowerMgmtPhasesTableCurrentMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of current sensor in this phase.( A x 10 )" ::= { acsPowerMgmtPhasesTableEntry 8 } acsPowerMgmtPhasesTableCurrentMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of current sensor in this phase.( A x 10 )" ::= { acsPowerMgmtPhasesTableEntry 9 } acsPowerMgmtPhasesTableCurrentAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for current sensor in this phase.( A x 10 )" ::= { acsPowerMgmtPhasesTableEntry 10 } acsPowerMgmtPhasesTableCurrentReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of current." ::= { acsPowerMgmtPhasesTableEntry 11 } acsPowerMgmtPhasesTableVoltageType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of voltage values." ::= { acsPowerMgmtPhasesTableEntry 12 } acsPowerMgmtPhasesTableVoltageValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of voltage sensor in this phase.( V )" ::= { acsPowerMgmtPhasesTableEntry 13 } acsPowerMgmtPhasesTableVoltageMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of voltage sensor in this phase.( V )" ::= { acsPowerMgmtPhasesTableEntry 14 } acsPowerMgmtPhasesTableVoltageMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of voltage sensor in this phase.( V )" ::= { acsPowerMgmtPhasesTableEntry 15 } acsPowerMgmtPhasesTableVoltageAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for voltage sensor in this phase.( V )" ::= { acsPowerMgmtPhasesTableEntry 16 } acsPowerMgmtPhasesTableVoltageReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of voltage." ::= { acsPowerMgmtPhasesTableEntry 17 } acsPowerMgmtPhasesTablePowerType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power consumption values." ::= { acsPowerMgmtPhasesTableEntry 18 } acsPowerMgmtPhasesTablePowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power consumption in this phase.( W x 10 )" ::= { acsPowerMgmtPhasesTableEntry 19 } acsPowerMgmtPhasesTablePowerMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power consumption in this phase.( W x 10 )" ::= { acsPowerMgmtPhasesTableEntry 20 } acsPowerMgmtPhasesTablePowerMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power consumption in this phase.( W x 10 )" ::= { acsPowerMgmtPhasesTableEntry 21 } acsPowerMgmtPhasesTablePowerAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power consumption in this phase.( W x 10 )" ::= { acsPowerMgmtPhasesTableEntry 22 } acsPowerMgmtPhasesTablePowerReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power consumption." ::= { acsPowerMgmtPhasesTableEntry 23 } acsPowerMgmtPhasesTablePowerFactorType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power factor values." ::= { acsPowerMgmtPhasesTableEntry 24 } acsPowerMgmtPhasesTablePowerFactorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power factor in this phase.( PF x 100 )" ::= { acsPowerMgmtPhasesTableEntry 25 } acsPowerMgmtPhasesTablePowerFactorMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power factor in this phase.( PF x 100 )" ::= { acsPowerMgmtPhasesTableEntry 26 } acsPowerMgmtPhasesTablePowerFactorMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power factor in this phase.( PF x 100 )" ::= { acsPowerMgmtPhasesTableEntry 27 } acsPowerMgmtPhasesTablePowerFactorAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power factor in this phase.( PF x 100 )" ::= { acsPowerMgmtPhasesTableEntry 28 } acsPowerMgmtPhasesTablePowerFactorReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power factor." ::= { acsPowerMgmtPhasesTableEntry 29 } acsPowerMgmtPhasesTableAlarm OBJECT-TYPE SYNTAX INTEGER { normal (1), blow-fuse (2), hw-ocp (3), high-critical (4), high-warning (5), low-warning (6), low-critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show the phase alarm status." ::= { acsPowerMgmtPhasesTableEntry 30 } acsPowerMgmtBanksTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtBanksTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data monitoring of each detected bank." ::= { acsPowerMgmt 9 } acsPowerMgmtBanksTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtBanksTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the data monitoring about bank." INDEX { acsPowerMgmtBanksTablePortNumber, acsPowerMgmtBanksTablePduIndex, acsPowerMgmtBanksTableBankIndex } ::= { acsPowerMgmtBanksTable 1 } AcsPowerMgmtBanksTableEntry ::= SEQUENCE { acsPowerMgmtBanksTablePortNumber InterfaceIndex, -- number of serial port acsPowerMgmtBanksTablePduIndex InterfaceIndexOrZero, -- number of PDU acsPowerMgmtBanksTableBankIndex InterfaceIndexOrZero, -- bank index acsPowerMgmtBanksTableBankName DisplayString, -- Bank Name acsPowerMgmtBanksTablePduId DisplayString, -- PDU identification acsPowerMgmtBanksTablePortName DisplayString, -- Serial Port Name acsPowerMgmtBanksTableCurrentValue Integer32, -- actual value of bank current sensor acsPowerMgmtBanksTableCurrentMax Integer32, -- max detected value of current sensor acsPowerMgmtBanksTableCurrentMin Integer32, -- min detected value of current sensor acsPowerMgmtBanksTableCurrentAvg Integer32, -- average value for current sensor acsPowerMgmtBanksTableCurrentReset INTEGER, -- reset max, min and avg values acsPowerMgmtBanksTableVoltageType INTEGER, -- type of bank voltage acsPowerMgmtBanksTableVoltageValue Integer32, -- actual value of bank voltage acsPowerMgmtBanksTableVoltageMax Integer32, -- max value of voltage sensor acsPowerMgmtBanksTableVoltageMin Integer32, -- min value of voltage sensor acsPowerMgmtBanksTableVoltageAvg Integer32, -- avg value of voltage sensor acsPowerMgmtBanksTableVoltageReset INTEGER, -- reset max, min and avg values acsPowerMgmtBanksTablePowerType INTEGER, -- type of bank power consumption acsPowerMgmtBanksTablePowerValue Integer32, -- actual value of bank power consumption acsPowerMgmtBanksTablePowerMax Integer32, -- max value acsPowerMgmtBanksTablePowerMin Integer32, -- min value acsPowerMgmtBanksTablePowerAvg Integer32, -- average value acsPowerMgmtBanksTablePowerReset INTEGER, -- reset max, min and avg values acsPowerMgmtBanksTablePowerFactorType INTEGER, -- type of bank power factor acsPowerMgmtBanksTablePowerFactorValue Integer32, -- actual value of bank power factor acsPowerMgmtBanksTablePowerFactorMax Integer32, -- max value for power factor acsPowerMgmtBanksTablePowerFactorMin Integer32, -- min value for power factor acsPowerMgmtBanksTablePowerFactorAvg Integer32, -- avg value for power factor acsPowerMgmtBanksTablePowerFactorReset INTEGER, -- reset max, min and avg values acsPowerMgmtBanksTableAlarm INTEGER -- status of bank alarm } acsPowerMgmtBanksTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of serial port when the PDU is connected." ::= { acsPowerMgmtBanksTableEntry 1 } acsPowerMgmtBanksTablePduIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A PDU position in the chain." ::= { acsPowerMgmtBanksTableEntry 2 } acsPowerMgmtBanksTableBankIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "Bank index in the PDU." ::= { acsPowerMgmtBanksTableEntry 3 } acsPowerMgmtBanksTableBankName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bank name in the PDU." ::= { acsPowerMgmtBanksTableEntry 4 } acsPowerMgmtBanksTablePduId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PDU identification." ::= { acsPowerMgmtBanksTableEntry 5 } acsPowerMgmtBanksTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of serial port when the PDU is connected." ::= { acsPowerMgmtBanksTableEntry 6 } acsPowerMgmtBanksTableCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of current sensor in this bank.( A x 10 )" ::= { acsPowerMgmtBanksTableEntry 7 } acsPowerMgmtBanksTableCurrentMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of current sensor in this bank.( A x 10 )" ::= { acsPowerMgmtBanksTableEntry 8 } acsPowerMgmtBanksTableCurrentMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of current sensor in this bank.( A x 10 )" ::= { acsPowerMgmtBanksTableEntry 9 } acsPowerMgmtBanksTableCurrentAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for current sensor in this bank.( A x 10 )" ::= { acsPowerMgmtBanksTableEntry 10 } acsPowerMgmtBanksTableCurrentReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of current." ::= { acsPowerMgmtBanksTableEntry 11 } acsPowerMgmtBanksTableVoltageType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of voltage values." ::= { acsPowerMgmtBanksTableEntry 12 } acsPowerMgmtBanksTableVoltageValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of voltage sensor in this bank.( V )" ::= { acsPowerMgmtBanksTableEntry 13 } acsPowerMgmtBanksTableVoltageMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of voltage sensor in this bank.( V )" ::= { acsPowerMgmtBanksTableEntry 14 } acsPowerMgmtBanksTableVoltageMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of voltage sensor in this bank.( V )" ::= { acsPowerMgmtBanksTableEntry 15 } acsPowerMgmtBanksTableVoltageAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for voltage sensor in this bank.( V )" ::= { acsPowerMgmtBanksTableEntry 16 } acsPowerMgmtBanksTableVoltageReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of voltage." ::= { acsPowerMgmtBanksTableEntry 17 } acsPowerMgmtBanksTablePowerType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power consumption values." ::= { acsPowerMgmtBanksTableEntry 18 } acsPowerMgmtBanksTablePowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power consumption in this bank.( W x 10 )" ::= { acsPowerMgmtBanksTableEntry 19 } acsPowerMgmtBanksTablePowerMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power consumption in this bank.( W x 10 )" ::= { acsPowerMgmtBanksTableEntry 20 } acsPowerMgmtBanksTablePowerMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power consumption in this bank.( W x 10 )" ::= { acsPowerMgmtBanksTableEntry 21 } acsPowerMgmtBanksTablePowerAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power consumption in this bank.( W x 10 )" ::= { acsPowerMgmtBanksTableEntry 22 } acsPowerMgmtBanksTablePowerReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power consumption." ::= { acsPowerMgmtBanksTableEntry 23 } acsPowerMgmtBanksTablePowerFactorType OBJECT-TYPE SYNTAX INTEGER { none-sensor (0), estimated (1), read (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Type of power factor values." ::= { acsPowerMgmtBanksTableEntry 24 } acsPowerMgmtBanksTablePowerFactorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of power factor in this bank.( PF x 100 )" ::= { acsPowerMgmtBanksTableEntry 25 } acsPowerMgmtBanksTablePowerFactorMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of power factor in this bank.( PF x 100 )" ::= { acsPowerMgmtBanksTableEntry 26 } acsPowerMgmtBanksTablePowerFactorMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of power factor in this bank.( PF x 100 )" ::= { acsPowerMgmtBanksTableEntry 27 } acsPowerMgmtBanksTablePowerFactorAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for power factor in this bank.( PF x 100 )" ::= { acsPowerMgmtBanksTableEntry 28 } acsPowerMgmtBanksTablePowerFactorReset OBJECT-TYPE SYNTAX INTEGER { no-action (1), reset (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avg values of power factor." ::= { acsPowerMgmtBanksTableEntry 29 } acsPowerMgmtBanksTableAlarm OBJECT-TYPE SYNTAX INTEGER { normal (1), blow-fuse (2), hw-ocp (3), high-critical (4), high-warning (5), low-warning (6), low-critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show the bank alarm status." ::= { acsPowerMgmtBanksTableEntry 30 } acsPowerMgmtEnvMonTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtEnvMonTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data monitoring of each detected environmental sensor." ::= { acsPowerMgmt 10 } acsPowerMgmtEnvMonTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtEnvMonTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the data monitoring about environmental sensors." INDEX { acsPowerMgmtEnvMonTablePortNumber, acsPowerMgmtEnvMonTablePduIndex, acsPowerMgmtEnvMonTableIndex } ::= { acsPowerMgmtEnvMonTable 1 } AcsPowerMgmtEnvMonTableEntry ::= SEQUENCE { acsPowerMgmtEnvMonTablePortNumber InterfaceIndex, -- number of serial port acsPowerMgmtEnvMonTablePduIndex InterfaceIndexOrZero, -- number of PDU acsPowerMgmtEnvMonTableIndex InterfaceIndexOrZero, -- index acsPowerMgmtEnvMonTableName DisplayString, -- sensor name acsPowerMgmtEnvMonTablePduId DisplayString, -- PDU identification acsPowerMgmtEnvMonTablePortName DisplayString, -- Serial Port Name acsPowerMgmtEnvMonTableType INTEGER, -- environmental sensor type acsPowerMgmtEnvMonTableStatus INTEGER, -- state of digital sensor acsPowerMgmtEnvMonTableValue Integer32, -- value acsPowerMgmtEnvMonTableMaxValue Integer32 -- max value } acsPowerMgmtEnvMonTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of serial port when the PDU is connected." ::= { acsPowerMgmtEnvMonTableEntry 1 } acsPowerMgmtEnvMonTablePduIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A PDU position in the chain." ::= { acsPowerMgmtEnvMonTableEntry 2 } acsPowerMgmtEnvMonTableIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "envmon sensor index." ::= { acsPowerMgmtEnvMonTableEntry 3 } acsPowerMgmtEnvMonTableName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "envmon sensor name." ::= { acsPowerMgmtEnvMonTableEntry 4 } acsPowerMgmtEnvMonTablePduId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "PDU identification." ::= { acsPowerMgmtEnvMonTableEntry 5 } acsPowerMgmtEnvMonTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of serial port when the PDU is connected." ::= { acsPowerMgmtEnvMonTableEntry 6 } acsPowerMgmtEnvMonTableType OBJECT-TYPE SYNTAX INTEGER { temp-internal (1), temperature (2), humidity (3), air-flow (4), smoke (5), dry-contact (6), water-level (7), motion (8), unplugged (9), unknown (10), air-pressure (11), vibration (12), vibration-contact (13), leak(14), door-contact (15) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of environmental monitor." ::= { acsPowerMgmtEnvMonTableEntry 7 } acsPowerMgmtEnvMonTableStatus OBJECT-TYPE SYNTAX INTEGER { normal(1), triggered(2), not-applicable(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor, Door-Contact. For Door-Contact, normal(1) = closed, triggered(2) = opened." ::= { acsPowerMgmtEnvMonTableEntry 8 } acsPowerMgmtEnvMonTableValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu." ::= { acsPowerMgmtEnvMonTableEntry 9 } acsPowerMgmtEnvMonTableMaxValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu." ::= { acsPowerMgmtEnvMonTableEntry 10 } acsPowerMgmtOutElecMonTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtOutElecMonTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about data monitoring of outlets." ::= { acsPowerMgmt 11 } acsPowerMgmtOutElecMonTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtOutElecMonTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the outlet." INDEX { acsPowerMgmtOutElecMonTablePortNumber, acsPowerMgmtOutElecMonTablePduNumber, acsPowerMgmtOutElecMonTableNumber } ::= { acsPowerMgmtOutElecMonTable 1 } AcsPowerMgmtOutElecMonTableEntry ::= SEQUENCE { acsPowerMgmtOutElecMonTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtOutElecMonTablePduNumber InterfaceIndex, acsPowerMgmtOutElecMonTableNumber InterfaceIndex, -- outlet number in PDU acsPowerMgmtOutElecMonTableCurrentValue Integer32, -- actual value for current acsPowerMgmtOutElecMonTableCurrentMax Integer32, -- max detected value for current acsPowerMgmtOutElecMonTableCurrentMin Integer32, -- min detected value for current acsPowerMgmtOutElecMonTableCurrentAvg Integer32, -- average value for current acsPowerMgmtOutElecMonTableCurrentReset INTEGER, -- reset max, min and avg values of current acsPowerMgmtOutElecMonTablePowerValue Integer32, -- actual value for power acsPowerMgmtOutElecMonTablePowerMax Integer32, -- max detected value for power acsPowerMgmtOutElecMonTablePowerMin Integer32, -- min detected value for power acsPowerMgmtOutElecMonTablePowerAvg Integer32, -- average value for power acsPowerMgmtOutElecMonTablePowerReset INTEGER, -- reset max, min and avg values of power acsPowerMgmtOutElecMonTableVoltageValue Integer32, -- actual value for voltage acsPowerMgmtOutElecMonTableVoltageMax Integer32, -- max detected value for voltage acsPowerMgmtOutElecMonTableVoltageMin Integer32, -- min detected value for voltage acsPowerMgmtOutElecMonTableVoltageAvg Integer32, -- average value for voltage acsPowerMgmtOutElecMonTableVoltageReset INTEGER, -- reset max, min and avg values of voltage acsPowerMgmtOutElecMonTablePowerFactorValue Integer32, -- actual value for power factor acsPowerMgmtOutElecMonTablePowerFactorMax Integer32, -- max detected value for power factor acsPowerMgmtOutElecMonTablePowerFactorMin Integer32, -- min detected value for power factor acsPowerMgmtOutElecMonTablePowerFactorAvg Integer32, -- avg value for power factor acsPowerMgmtOutElecMonTablePowerFactorReset INTEGER, -- reset max, min and avg values of power factor acsPowerMgmtOutElecMonTableAlarm INTEGER -- outlet alarm status } acsPowerMgmtOutElecMonTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtOutElecMonTableEntry 1 } acsPowerMgmtOutElecMonTablePduNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtOutElecMonTableEntry 2 } acsPowerMgmtOutElecMonTableNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the outlet in the PDU." ::= { acsPowerMgmtOutElecMonTableEntry 3 } acsPowerMgmtOutElecMonTableCurrentValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of outlet current sensor.( A x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 4 } acsPowerMgmtOutElecMonTableCurrentMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of outlet current sensor.( A x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 5 } acsPowerMgmtOutElecMonTableCurrentMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of outlet current sensor.( A x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 6 } acsPowerMgmtOutElecMonTableCurrentAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for outlet current sensor.( A x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 7 } acsPowerMgmtOutElecMonTableCurrentReset OBJECT-TYPE SYNTAX INTEGER { noAction(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avertage values of outlet current." ::= { acsPowerMgmtOutElecMonTableEntry 8 } acsPowerMgmtOutElecMonTablePowerValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of outlet power comsumption sensor.( W x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 9 } acsPowerMgmtOutElecMonTablePowerMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of outlet power comsumption sensor.( W x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 10 } acsPowerMgmtOutElecMonTablePowerMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of outlet power comsumption sensor.( W x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 11 } acsPowerMgmtOutElecMonTablePowerAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for outlet power comsumption sensor.( W x 10 )" ::= { acsPowerMgmtOutElecMonTableEntry 12 } acsPowerMgmtOutElecMonTablePowerReset OBJECT-TYPE SYNTAX INTEGER { noAction(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avertage values of outlet power comsumption." ::= { acsPowerMgmtOutElecMonTableEntry 13 } acsPowerMgmtOutElecMonTableVoltageValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of outlet voltage sensor.( V )" ::= { acsPowerMgmtOutElecMonTableEntry 14 } acsPowerMgmtOutElecMonTableVoltageMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of outlet voltage sensor.( V )" ::= { acsPowerMgmtOutElecMonTableEntry 15 } acsPowerMgmtOutElecMonTableVoltageMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of outlet voltage sensor.( V )" ::= { acsPowerMgmtOutElecMonTableEntry 16 } acsPowerMgmtOutElecMonTableVoltageAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for outlet voltage sensor.( V )" ::= { acsPowerMgmtOutElecMonTableEntry 17 } acsPowerMgmtOutElecMonTableVoltageReset OBJECT-TYPE SYNTAX INTEGER { noAction(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avertage values of outlet voltage." ::= { acsPowerMgmtOutElecMonTableEntry 18 } acsPowerMgmtOutElecMonTablePowerFactorValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Actual value of outlet power-factor sensor.( PF x 100 )" ::= { acsPowerMgmtOutElecMonTableEntry 19 } acsPowerMgmtOutElecMonTablePowerFactorMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max detected value of outlet power-factor sensor.( PF x 100 )" ::= { acsPowerMgmtOutElecMonTableEntry 20 } acsPowerMgmtOutElecMonTablePowerFactorMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min detected value of outlet power-factor sensor.( PF x 100 )" ::= { acsPowerMgmtOutElecMonTableEntry 21 } acsPowerMgmtOutElecMonTablePowerFactorAvg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average value for outlet power-factor sensor.( PF x 100 )" ::= { acsPowerMgmtOutElecMonTableEntry 22 } acsPowerMgmtOutElecMonTablePowerFactorReset OBJECT-TYPE SYNTAX INTEGER { noAction(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset max, min and avertage values of outlet power-factor." ::= { acsPowerMgmtOutElecMonTableEntry 23 } acsPowerMgmtOutElecMonTableAlarm OBJECT-TYPE SYNTAX INTEGER { normal (1), blow-fuse (2), hw-ocp (3), high-critical (4), high-warning (5), low-warning (6), low-critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show the outlet alarm status." ::= { acsPowerMgmtOutElecMonTableEntry 24 } acsPowerMgmtUPSTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the list of detected UPSs." ::= { acsPowerMgmt 12 } acsPowerMgmtUPSTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry has the information about the UPS." INDEX { acsPowerMgmtUPSTablePortNumber, acsPowerMgmtUPSTableUpsIndex } ::= { acsPowerMgmtUPSTable 1 } AcsPowerMgmtUPSTableEntry ::= SEQUENCE { acsPowerMgmtUPSTablePortNumber InterfaceIndex, -- number of serial port acsPowerMgmtUPSTableUpsIndex InterfaceIndexOrZero, acsPowerMgmtUPSTableUpsId DisplayString, -- UPS identification acsPowerMgmtUPSTablePortName DisplayString, -- Serial Port Name or IP address if network device acsPowerMgmtUPSTableModel DisplayString, acsPowerMgmtUPSTableVendor DisplayString, acsPowerMgmtUPSTableFirmwareVersion DisplayString, acsPowerMgmtUPSTableAgentFirmwareVersion DisplayString, acsPowerMgmtUPSTableSystemStatus DisplayString, acsPowerMgmtUPSTableInputBlackOutCount Integer32, acsPowerMgmtUPSTableInputBrownOutCount Integer32, acsPowerMgmtUPSTableInletAirTemperature DisplayString, acsPowerMgmtUPSTableNumberOutletGroups Integer32, acsPowerMgmtUPSTableUPSSerialNumber DisplayString, acsPowerMgmtUPSTableUPSManufactureDate DisplayString, acsPowerMgmtUPSTableAutoRestartDelay Integer32, acsPowerMgmtUPSTableAutoRestartControl INTEGER, acsPowerMgmtUPSTableAudibleAlarmControl INTEGER, acsPowerMgmtUPSTableSilenceAlarm Integer32, acsPowerMgmtUPSTableInverterState DisplayString, acsPowerMgmtUPSTableDCConverterStatus DisplayString, acsPowerMgmtUPSTableShutdownReason DisplayString, acsPowerMgmtUPSTableUPSTopology DisplayString, acsPowerMgmtUPSTableBypassInverterInputConfig DisplayString } acsPowerMgmtUPSTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of serial port when the UPS is connected." ::= { acsPowerMgmtUPSTableEntry 1 } acsPowerMgmtUPSTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-only STATUS current DESCRIPTION "A UPS position in the chain." ::= { acsPowerMgmtUPSTableEntry 2 } acsPowerMgmtUPSTableUpsId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "UPS identification." ::= { acsPowerMgmtUPSTableEntry 3 } acsPowerMgmtUPSTablePortName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of serial port or IP address if network device" ::= { acsPowerMgmtUPSTableEntry 4 } acsPowerMgmtUPSTableModel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Model of the UPS." ::= { acsPowerMgmtUPSTableEntry 5 } acsPowerMgmtUPSTableVendor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor of the UPS." ::= { acsPowerMgmtUPSTableEntry 6 } acsPowerMgmtUPSTableFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version of the UPS firmware." ::= { acsPowerMgmtUPSTableEntry 7 } acsPowerMgmtUPSTableAgentFirmwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Firmware version of the agent card." ::= { acsPowerMgmtUPSTableEntry 8 } acsPowerMgmtUPSTableSystemStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System Status of the UPS." ::= { acsPowerMgmtUPSTableEntry 9 } acsPowerMgmtUPSTableInputBlackOutCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences, since the last reset, where the input was not qualified to provide power to the system." ::= { acsPowerMgmtUPSTableEntry 10 } acsPowerMgmtUPSTableInputBrownOutCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of occurrences, since the last reset, where the system input voltage has fallen below a pre-determined threshold for a specified amount of time." ::= { acsPowerMgmtUPSTableEntry 11 } acsPowerMgmtUPSTableInletAirTemperature OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the inlet air." ::= { acsPowerMgmtUPSTableEntry 12 } acsPowerMgmtUPSTableNumberOutletGroups OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Outlet Groups on this UPS" ::= { acsPowerMgmtUPSTableEntry 13 } acsPowerMgmtUPSTableUPSSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System serial number." ::= { acsPowerMgmtUPSTableEntry 14 } acsPowerMgmtUPSTableUPSManufactureDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Manufacturing date of the system." ::= { acsPowerMgmtUPSTableEntry 15 } acsPowerMgmtUPSTableAutoRestartDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "If power is lost, the control will delay this amount of time after power is restored before restarting the unit." ::= { acsPowerMgmtUPSTableEntry 16 } acsPowerMgmtUPSTableAutoRestartControl OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set to enabled, the UPS will automatically restart the load when utility power is restored after a battery discharge." ::= { acsPowerMgmtUPSTableEntry 17 } acsPowerMgmtUPSTableAudibleAlarmControl OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Audible alarm control." ::= { acsPowerMgmtUPSTableEntry 18 } acsPowerMgmtUPSTableSilenceAlarm OBJECT-TYPE SYNTAX INTEGER { noAction(0), silenceAlarm(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Silence audible alarm." ::= { acsPowerMgmtUPSTableEntry 19 } acsPowerMgmtUPSTableInverterState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inverter on/off state." ::= { acsPowerMgmtUPSTableEntry 20 } acsPowerMgmtUPSTableDCConverterStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The operating state of the dc converter." ::= { acsPowerMgmtUPSTableEntry 21 } acsPowerMgmtUPSTableShutdownReason OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The reason for the most recent shutdown." ::= { acsPowerMgmtUPSTableEntry 22 } acsPowerMgmtUPSTableUPSTopology OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "UPS Topology." ::= { acsPowerMgmtUPSTableEntry 23 } acsPowerMgmtUPSTableBypassInverterInputConfig OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input source configuration for the bypass and inverter." ::= { acsPowerMgmtUPSTableEntry 24 } -- -- acsPowerMgmtUPSInputTable ::= { acsPowerMgmt 13 } -- acsPowerMgmtUPSInputTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSInputTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about UPS inputs." ::= { acsPowerMgmt 13 } acsPowerMgmtUPSInputTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSInputTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the UPS inputs." INDEX { acsPowerMgmtUPSInputTablePortNumber, acsPowerMgmtUPSInputTableUpsIndex } ::= { acsPowerMgmtUPSInputTable 1 } AcsPowerMgmtUPSInputTableEntry ::= SEQUENCE { acsPowerMgmtUPSInputTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSInputTableUpsIndex InterfaceIndex, acsPowerMgmtUPSInputTableFrequency DisplayString, acsPowerMgmtUPSInputTableRMSVoltageL1N DisplayString, acsPowerMgmtUPSInputTableRMSVoltageL1L2 DisplayString, acsPowerMgmtUPSInputTableRMSVoltageL2N DisplayString, acsPowerMgmtUPSInputTableRMSCurrentL1 DisplayString, acsPowerMgmtUPSInputTableRMSCurrentL2 DisplayString, acsPowerMgmtUPSInputTableMaxVoltageL1N DisplayString, acsPowerMgmtUPSInputTableMinVoltageL1N DisplayString, acsPowerMgmtUPSInputTableMaxVoltageL2N DisplayString, acsPowerMgmtUPSInputTableMinVoltageL2N DisplayString, acsPowerMgmtUPSInputTableNominalVoltage DisplayString, acsPowerMgmtUPSInputTableNominalFrequency DisplayString, acsPowerMgmtUPSInputTableNominalCurrent DisplayString } acsPowerMgmtUPSInputTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSInputTableEntry 1 } acsPowerMgmtUPSInputTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSInputTableEntry 2 } acsPowerMgmtUPSInputTableFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input Frequency." ::= { acsPowerMgmtUPSInputTableEntry 3 } acsPowerMgmtUPSInputTableRMSVoltageL1N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L1-N." ::= { acsPowerMgmtUPSInputTableEntry 4 } acsPowerMgmtUPSInputTableRMSVoltageL1L2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L1L2." ::= { acsPowerMgmtUPSInputTableEntry 5 } acsPowerMgmtUPSInputTableRMSVoltageL2N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L2N." ::= { acsPowerMgmtUPSInputTableEntry 6 } acsPowerMgmtUPSInputTableRMSCurrentL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Current for L1." ::= { acsPowerMgmtUPSInputTableEntry 7 } acsPowerMgmtUPSInputTableRMSCurrentL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Current for L2." ::= { acsPowerMgmtUPSInputTableEntry 8 } acsPowerMgmtUPSInputTableMaxVoltageL1N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input Max Voltage measurement for Line L1-N since the last reset." ::= { acsPowerMgmtUPSInputTableEntry 9 } acsPowerMgmtUPSInputTableMinVoltageL1N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input Min Voltage measurement for Line L1-N since the last reset." ::= { acsPowerMgmtUPSInputTableEntry 10 } acsPowerMgmtUPSInputTableMaxVoltageL2N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input Max Voltage measurement for Line L2-N since the last reset." ::= { acsPowerMgmtUPSInputTableEntry 11 } acsPowerMgmtUPSInputTableMinVoltageL2N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input Min Voltage measurement for Line L1-N since the last reset." ::= { acsPowerMgmtUPSInputTableEntry 12 } acsPowerMgmtUPSInputTableNominalVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input nominal voltage." ::= { acsPowerMgmtUPSInputTableEntry 13 } acsPowerMgmtUPSInputTableNominalFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input nominal frequency." ::= { acsPowerMgmtUPSInputTableEntry 14 } acsPowerMgmtUPSInputTableNominalCurrent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Input nominal current." ::= { acsPowerMgmtUPSInputTableEntry 15 } -- -- acsPowerMgmtUPSBypassTable ::= { acsPowerMgmt 14 } -- acsPowerMgmtUPSBypassTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSBypassTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about UPS bypass." ::= { acsPowerMgmt 14 } acsPowerMgmtUPSBypassTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSBypassTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the UPS bypass." INDEX { acsPowerMgmtUPSBypassTablePortNumber, acsPowerMgmtUPSBypassTableUpsIndex } ::= { acsPowerMgmtUPSBypassTable 1 } AcsPowerMgmtUPSBypassTableEntry ::= SEQUENCE { acsPowerMgmtUPSBypassTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSBypassTableUpsIndex InterfaceIndex, acsPowerMgmtUPSBypassTableRMSVoltageL1N DisplayString, acsPowerMgmtUPSBypassTableRMSVoltageL1L2 DisplayString, acsPowerMgmtUPSBypassTableRMSVoltageL2N DisplayString, acsPowerMgmtUPSBypassTableRMSCurrent DisplayString, acsPowerMgmtUPSBypassTableRMSCurrentL2 DisplayString, acsPowerMgmtUPSBypassTableInputFrequency DisplayString, acsPowerMgmtUPSBypassTableNominalVoltage DisplayString } acsPowerMgmtUPSBypassTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSBypassTableEntry 1 } acsPowerMgmtUPSBypassTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSBypassTableEntry 2 } acsPowerMgmtUPSBypassTableRMSVoltageL1N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L1N." ::= { acsPowerMgmtUPSBypassTableEntry 3 } acsPowerMgmtUPSBypassTableRMSVoltageL1L2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L1L2." ::= { acsPowerMgmtUPSBypassTableEntry 4 } acsPowerMgmtUPSBypassTableRMSVoltageL2N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Voltage L2N." ::= { acsPowerMgmtUPSBypassTableEntry 5 } acsPowerMgmtUPSBypassTableRMSCurrent OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Current." ::= { acsPowerMgmtUPSBypassTableEntry 6 } acsPowerMgmtUPSBypassTableRMSCurrentL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "RMS Current." ::= { acsPowerMgmtUPSBypassTableEntry 7 } acsPowerMgmtUPSBypassTableInputFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass Input Frequency." ::= { acsPowerMgmtUPSBypassTableEntry 8 } acsPowerMgmtUPSBypassTableNominalVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bypass Nominal Voltage." ::= { acsPowerMgmtUPSBypassTableEntry 9 } -- -- acsPowerMgmtUPSBatteryTable ::= { acsPowerMgmt 15 } -- acsPowerMgmtUPSBatteryTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSBatteryTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about UPS battery." ::= { acsPowerMgmt 15 } acsPowerMgmtUPSBatteryTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSBatteryTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the UPS bypass." INDEX { acsPowerMgmtUPSBatteryTablePortNumber, acsPowerMgmtUPSBatteryTableUpsIndex } ::= { acsPowerMgmtUPSBatteryTable 1 } AcsPowerMgmtUPSBatteryTableEntry ::= SEQUENCE { acsPowerMgmtUPSBatteryTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSBatteryTableUpsIndex InterfaceIndex, acsPowerMgmtUPSBatteryTableDCBusVoltage DisplayString, acsPowerMgmtUPSBatteryTableTimeRemaining DisplayString, acsPowerMgmtUPSBatteryTablePercentageCharge DisplayString, acsPowerMgmtUPSBatteryTableChargeStatus DisplayString, acsPowerMgmtUPSBatteryTableLowBatteryWarningTime INTEGER, acsPowerMgmtUPSBatteryTableTestResult DisplayString, acsPowerMgmtUPSBatteryTableDCBusNominalVoltage DisplayString, acsPowerMgmtUPSBatteryTableNominalBatteryCapacity DisplayString, acsPowerMgmtUPSBatteryTableBatteryFloatVoltage DisplayString, acsPowerMgmtUPSBatteryTableBatteryCabinetType DisplayString, acsPowerMgmtUPSBatteryTableBatteryNumberOfEBC DisplayString, acsPowerMgmtUPSBatteryTableBatteryRating DisplayString, acsPowerMgmtUPSBatteryTableBatteryDischargeTime DisplayString, acsPowerMgmtUPSBatteryTableBatteryChargeCompensating DisplayString, acsPowerMgmtUPSBatteryTableBatteryChargerState DisplayString, acsPowerMgmtUPSBatteryTableStartBatteryTest INTEGER, acsPowerMgmtUPSBatteryTableBatteryStatus DisplayString } acsPowerMgmtUPSBatteryTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSBatteryTableEntry 1 } acsPowerMgmtUPSBatteryTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSBatteryTableEntry 2 } acsPowerMgmtUPSBatteryTableDCBusVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "DC Bus Voltage" ::= { acsPowerMgmtUPSBatteryTableEntry 3 } acsPowerMgmtUPSBatteryTableTimeRemaining OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The calculated available time on battery." ::= { acsPowerMgmtUPSBatteryTableEntry 4 } acsPowerMgmtUPSBatteryTablePercentageCharge OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Percentage Charge." ::= { acsPowerMgmtUPSBatteryTableEntry 5 } acsPowerMgmtUPSBatteryTableChargeStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Charge Status." ::= { acsPowerMgmtUPSBatteryTableEntry 6 } acsPowerMgmtUPSBatteryTableLowBatteryWarningTime OBJECT-TYPE SYNTAX INTEGER (2..30) MAX-ACCESS read-write STATUS current DESCRIPTION "When battery time remaining falls to, or below, this value (minutes) the low battery alarm is activated." ::= { acsPowerMgmtUPSBatteryTableEntry 7 } acsPowerMgmtUPSBatteryTableTestResult OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The outcome of the previous battery test." ::= { acsPowerMgmtUPSBatteryTableEntry 8 } acsPowerMgmtUPSBatteryTableDCBusNominalVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery DC Bus Nominal Voltage." ::= { acsPowerMgmtUPSBatteryTableEntry 9 } acsPowerMgmtUPSBatteryTableNominalBatteryCapacity OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Nominal Battery Capacity." ::= { acsPowerMgmtUPSBatteryTableEntry 10 } acsPowerMgmtUPSBatteryTableBatteryFloatVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Float Voltage." ::= { acsPowerMgmtUPSBatteryTableEntry 11 } acsPowerMgmtUPSBatteryTableBatteryCabinetType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Cabinet Type." ::= { acsPowerMgmtUPSBatteryTableEntry 12 } acsPowerMgmtUPSBatteryTableBatteryNumberOfEBC OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Extended Battery Cabinets installed." ::= { acsPowerMgmtUPSBatteryTableEntry 13 } acsPowerMgmtUPSBatteryTableBatteryRating OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Rating." ::= { acsPowerMgmtUPSBatteryTableEntry 14 } acsPowerMgmtUPSBatteryTableBatteryDischargeTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Time on battery operation for this discharge" ::= { acsPowerMgmtUPSBatteryTableEntry 15 } acsPowerMgmtUPSBatteryTableBatteryChargeCompensating OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery charge algorithm changed due to battery temperature." ::= { acsPowerMgmtUPSBatteryTableEntry 16 } acsPowerMgmtUPSBatteryTableBatteryChargerState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery charger state." ::= { acsPowerMgmtUPSBatteryTableEntry 17 } acsPowerMgmtUPSBatteryTableStartBatteryTest OBJECT-TYPE SYNTAX INTEGER { noAction(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Command to initate a manual battery test." ::= { acsPowerMgmtUPSBatteryTableEntry 18 } acsPowerMgmtUPSBatteryTableBatteryStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Battery Status." ::= { acsPowerMgmtUPSBatteryTableEntry 19 } -- -- acsPowerMgmtUPSOutputTable ::= { acsPowerMgmt 16 } -- acsPowerMgmtUPSOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSOutputTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about UPS output." ::= { acsPowerMgmt 16 } acsPowerMgmtUPSOutputTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSOutputTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry has the information about the UPS output." INDEX { acsPowerMgmtUPSOutputTablePortNumber, acsPowerMgmtUPSOutputTableUpsIndex } ::= { acsPowerMgmtUPSOutputTable 1 } AcsPowerMgmtUPSOutputTableEntry ::= SEQUENCE { acsPowerMgmtUPSOutputTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSOutputTableUpsIndex InterfaceIndex, acsPowerMgmtUPSOutputTableApparentPower DisplayString, acsPowerMgmtUPSOutputTableFrequency DisplayString, acsPowerMgmtUPSOutputTablePercentPower DisplayString, acsPowerMgmtUPSOutputTablePercentPowerL1 DisplayString, acsPowerMgmtUPSOutputTablePercentPowerL2 DisplayString, acsPowerMgmtUPSOutputTablePower DisplayString, acsPowerMgmtUPSOutputTableRMSCurrentL1 DisplayString, acsPowerMgmtUPSOutputTableRMSCurrentL2 DisplayString, acsPowerMgmtUPSOutputTableRMSVoltageL1N DisplayString, acsPowerMgmtUPSOutputTableRMSVoltageL2N DisplayString, acsPowerMgmtUPSOutputTableRMSVoltageL1L2 DisplayString, acsPowerMgmtUPSOutputOffDelay INTEGER, acsPowerMgmtUPSOutputOnDelay INTEGER, acsPowerMgmtUPSOutputCycleDelay INTEGER, acsPowerMgmtUPSOutputTableMaxVoltageL1 DisplayString, acsPowerMgmtUPSOutputTableMinVoltageL1 DisplayString, acsPowerMgmtUPSOutputTableMaxVoltageL2 DisplayString, acsPowerMgmtUPSOutputTableMinVoltageL2 DisplayString, acsPowerMgmtUPSOutputTableNominalVoltage DisplayString, acsPowerMgmtUPSOutputTablePowerNominalFrequency DisplayString, acsPowerMgmtUPSOutputTablePowerApparentPowerRating DisplayString, acsPowerMgmtUPSOutputTablePowerNominalPowerFactor DisplayString, acsPowerMgmtUPSOutputTablePowerPowerFactorCorrection DisplayString, acsPowerMgmtUPSOutputTablePowerL1 DisplayString, acsPowerMgmtUPSOutputTablePowerL2 DisplayString, acsPowerMgmtUPSOutputTableApparentPowerL1 DisplayString, acsPowerMgmtUPSOutputTableApparentPowerL2 DisplayString } acsPowerMgmtUPSOutputTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSOutputTableEntry 1 } acsPowerMgmtUPSOutputTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSOutputTableEntry 2 } acsPowerMgmtUPSOutputTableApparentPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "DC Bus Voltage" ::= { acsPowerMgmtUPSOutputTableEntry 3 } acsPowerMgmtUPSOutputTableFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Output frequency." ::= { acsPowerMgmtUPSOutputTableEntry 4 } acsPowerMgmtUPSOutputTablePercentPower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output power as a percentage of the rated capacity." ::= { acsPowerMgmtUPSOutputTableEntry 5 } acsPowerMgmtUPSOutputTablePercentPowerL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output power on line L1 as a percentage of the rated capacity." ::= { acsPowerMgmtUPSOutputTableEntry 6 } acsPowerMgmtUPSOutputTablePercentPowerL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output power on line L2 as a percentage of the rated capacity." ::= { acsPowerMgmtUPSOutputTableEntry 7 } acsPowerMgmtUPSOutputTablePower OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The sum total power of all system output phases." ::= { acsPowerMgmtUPSOutputTableEntry 8 } acsPowerMgmtUPSOutputTableRMSCurrentL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System output RMS current for line L1." ::= { acsPowerMgmtUPSOutputTableEntry 9 } acsPowerMgmtUPSOutputTableRMSCurrentL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "System output RMS current for line L2." ::= { acsPowerMgmtUPSOutputTableEntry 10 } acsPowerMgmtUPSOutputTableRMSVoltageL1N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output RMS voltage." ::= { acsPowerMgmtUPSOutputTableEntry 11 } acsPowerMgmtUPSOutputTableRMSVoltageL2N OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output RMS voltage." ::= { acsPowerMgmtUPSOutputTableEntry 12 } acsPowerMgmtUPSOutputTableRMSVoltageL1L2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output RMS voltage." ::= { acsPowerMgmtUPSOutputTableEntry 13 } acsPowerMgmtUPSOutputOffDelay OBJECT-TYPE SYNTAX INTEGER (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Turns the UPS output off after the number of seconds specified. When a value is written to this object the output will be turned off after the specified time has elapsed and the output will remain off." ::= { acsPowerMgmtUPSOutputTableEntry 14 } acsPowerMgmtUPSOutputOnDelay OBJECT-TYPE SYNTAX INTEGER (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Turns the UPS output on after the number of seconds specified. When a value is written to this object the output will be turned on after the specified time has elapsed." ::= { acsPowerMgmtUPSOutputTableEntry 15 } acsPowerMgmtUPSOutputCycleDelay OBJECT-TYPE SYNTAX INTEGER (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Turns the UPS off and then back on after the number of seconds specified. When a value is written to this object the output will turned off immediately and then turned back on after the specified time has elapsed." ::= { acsPowerMgmtUPSOutputTableEntry 16 } acsPowerMgmtUPSOutputTableMaxVoltageL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum system output voltage measurement for line 1 since the last reset." ::= { acsPowerMgmtUPSOutputTableEntry 17 } acsPowerMgmtUPSOutputTableMinVoltageL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum system output voltage measurement for line 1 since the last reset." ::= { acsPowerMgmtUPSOutputTableEntry 18 } acsPowerMgmtUPSOutputTableMaxVoltageL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum system output voltage measurement for line 21 since the last reset." ::= { acsPowerMgmtUPSOutputTableEntry 19 } acsPowerMgmtUPSOutputTableMinVoltageL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum system output voltage measurement for line 2 since the last reset." ::= { acsPowerMgmtUPSOutputTableEntry 20 } acsPowerMgmtUPSOutputTableNominalVoltage OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal (or rated) system output voltage." ::= { acsPowerMgmtUPSOutputTableEntry 21 } acsPowerMgmtUPSOutputTablePowerNominalFrequency OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal (or rated) system output frequency." ::= { acsPowerMgmtUPSOutputTableEntry 22 } acsPowerMgmtUPSOutputTablePowerApparentPowerRating OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Output apparent power rating." ::= { acsPowerMgmtUPSOutputTableEntry 23 } acsPowerMgmtUPSOutputTablePowerNominalPowerFactor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal (or rated) system power factor." ::= { acsPowerMgmtUPSOutputTableEntry 24 } acsPowerMgmtUPSOutputTablePowerPowerFactorCorrection OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The state of the power factor correction circuitry of the system." ::= { acsPowerMgmtUPSOutputTableEntry 25 } acsPowerMgmtUPSOutputTablePowerL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output power on line 1." ::= { acsPowerMgmtUPSOutputTableEntry 26 } acsPowerMgmtUPSOutputTablePowerL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output power on line 2." ::= { acsPowerMgmtUPSOutputTableEntry 27 } acsPowerMgmtUPSOutputTableApparentPowerL1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output apparent power on line 1." ::= { acsPowerMgmtUPSOutputTableEntry 28 } acsPowerMgmtUPSOutputTableApparentPowerL2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The system output apparent power on line 2." ::= { acsPowerMgmtUPSOutputTableEntry 29 } -- -- acsPowerMgmtUPSEcoModeTable ::= { acsPowerMgmt 17 } -- acsPowerMgmtUPSEcoModeTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSEcoModeTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about UPS ECO Mode." ::= { acsPowerMgmt 17 } acsPowerMgmtUPSEcoModeTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSEcoModeTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "each entry has the information about the UPS ECO Mode." INDEX { acsPowerMgmtUPSBypassTablePortNumber, acsPowerMgmtUPSBypassTableUpsIndex } ::= { acsPowerMgmtUPSEcoModeTable 1 } AcsPowerMgmtUPSEcoModeTableEntry ::= SEQUENCE { acsPowerMgmtUPSEcoModeTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSEcoModeTableUpsIndex InterfaceIndex, acsPowerMgmtUPSEcoModeTableStatus DisplayString, acsPowerMgmtUPSEcoModeTableStateControl INTEGER } acsPowerMgmtUPSEcoModeTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSEcoModeTableEntry 1 } acsPowerMgmtUPSEcoModeTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSEcoModeTableEntry 2 } acsPowerMgmtUPSEcoModeTableStatus OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Current ECO Mode Status." ::= { acsPowerMgmtUPSEcoModeTableEntry 3 } acsPowerMgmtUPSEcoModeTableStateControl OBJECT-TYPE SYNTAX INTEGER { noAction(1), enable(2), disable(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable ECO mode." ::= { acsPowerMgmtUPSEcoModeTableEntry 4 } -- -- acsPowerMgmtUPSOutletGroupTable ::= { acsPowerMgmt 18 } -- acsPowerMgmtUPSOutletGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF AcsPowerMgmtUPSOutletGroupTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the UPS Outlet Group Information." ::= { acsPowerMgmt 18 } acsPowerMgmtUPSOutletGroupTableEntry OBJECT-TYPE SYNTAX AcsPowerMgmtUPSOutletGroupTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each entry has the UPS outlet group information." INDEX { acsPowerMgmtUPSOutletGroupTablePortNumber, acsPowerMgmtUPSOutletGroupTableUpsIndex, acsPowerMgmtUPSOutletGroupTableNumber } ::= { acsPowerMgmtUPSOutletGroupTable 1 } AcsPowerMgmtUPSOutletGroupTableEntry ::= SEQUENCE { acsPowerMgmtUPSOutletGroupTablePortNumber InterfaceIndex, -- serial port # acsPowerMgmtUPSOutletGroupTableUpsIndex InterfaceIndex, acsPowerMgmtUPSOutletGroupTableNumber InterfaceIndex, acsPowerMgmtUPSOutletGroupTableLabel DisplayString, acsPowerMgmtUPSOutletGroupTableState DisplayString, acsPowerMgmtUPSOutletGroupTablePowerControl INTEGER -- manage the outlet group } acsPowerMgmtUPSOutletGroupTablePortNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Serial Port number." ::= { acsPowerMgmtUPSOutletGroupTableEntry 1 } acsPowerMgmtUPSOutletGroupTableUpsIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Index." ::= { acsPowerMgmtUPSOutletGroupTableEntry 2 } acsPowerMgmtUPSOutletGroupTableNumber OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "Number of the outletgroup in the UPS." ::= { acsPowerMgmtUPSOutletGroupTableEntry 3 } acsPowerMgmtUPSOutletGroupTableLabel OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "User-defined label for the outlet group." ::= { acsPowerMgmtUPSOutletGroupTableEntry 4 } acsPowerMgmtUPSOutletGroupTableState OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "User-defined label for the outlet group." ::= { acsPowerMgmtUPSOutletGroupTableEntry 5 } acsPowerMgmtUPSOutletGroupTablePowerControl OBJECT-TYPE SYNTAX INTEGER { noAction(1), powerOn(2), powerOff(3), powerCycle(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "A set value of power(2-6) will send command to the UPS. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to UPS. powerOff(3) = when SET the power Off command is sent to UPS. powerCycle(4)=when SET the power cycle command is sent to UPS." ::= { acsPowerMgmtUPSOutletGroupTableEntry 6 } END