-- ***************************************************************** -- CISCO-MPLS-TE-STD-EXT-MIB.my -- -- April 2010, Salvatore Valenza -- August 2016, Amin Qassoud, Dragos Liciu -- -- Copyright (c) 2009-2016 by cisco Systems, Inc. -- All rights reserved. -- -- ***************************************************************** CISCO-MPLS-TE-STD-EXT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32, Unsigned32, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF TEXTUAL-CONVENTION FROM SNMPv2-TC mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId, mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, mplsTunnelARHopListIndex FROM MPLS-TE-STD-MIB InetAddressType, InetAddress FROM INET-ADDRESS-MIB ciscoMgmt FROM CISCO-SMI; cmplsTeStdExtMIB MODULE-IDENTITY LAST-UPDATED "201608050000Z" ORGANIZATION "Cisco Systems, Inc." CONTACT-INFO "Cisco Systems Customer Service Postal: 170 W Tasman Drive San Jose, CA 95134 USA Tel: +1 800 553-NETS E-mail: cs-snmp@cisco.com" DESCRIPTION "This MIB module contains Cisco specific managed object definitions for MPLS Traffic Engineering (TE), not contained in MPLS-TE-STD-MIB. The auto bandwidth feature enables MPLS TE Tunnels to adapt automatically their bandwidth to their actual load." REVISION "201608050000Z" DESCRIPTION "Added a new table cmplsTunnelLoadshareTable. Added a new scalar object cmplsTeLoadshareBalance. Added new values to cmplsTunnelReoptReason. Added a new object cmplsTeFailReasonRev which deprecates cmplsTeFailReason. Updated cmplsTeFailReason description and MIN-ACCESS in complaince. Added new value frrSoftPreemption to cmplsTunnelPreemptionType. Deprecated the complaince cmplsTeStdExtMIBComplianceRev3 and group cmplsTeStdExtMIBFailTeTrapObjectsGroup. Added new complaince cmplsTeStdExtMIBComplianceRev4 and groups cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 and cmplsTeStdExtMIBLoadShareObjectsGroup." REVISION "201202220000Z" DESCRIPTION "Add preferredTreeExists to cmplsTunnelReooptReason" REVISION "201110040000Z" DESCRIPTION "Added cmplsTeBringupFail trap" REVISION "201101070000Z" DESCRIPTION "Added softPreemption to the enum cmplsTunnelReoptReason." REVISION "201010200000Z" DESCRIPTION "added cmplsTunnelReRoutePendingClearReason to be sent along the notification cmplsTunnelReRoutePendingClear" REVISION "201009230000Z" DESCRIPTION "New traps and related objects definitions." REVISION "201005270000Z" DESCRIPTION "Initial version of this MIB module." ::= { ciscoMgmt 738 } CmplsTeTunnelDiag ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "A common TE diagnostic code - unknown: failure reason unknown - bfdSessionBringupTimeout: BFD session failed to come up before timeout" SYNTAX INTEGER { unknonw(1), bfdSessionBringupTimeout(2) } CmplsTunnelBWPercent ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "A fraction of the bandwidth expressed in percentage." SYNTAX Unsigned32 (0..100) -- Textual Conventions definition will be defined before this line cmplsTeStdExtMIBNotifs OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 0 } cmplsTeStdExtMIBObjects OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 1 } cmplsTeStdExtMIBConform OBJECT IDENTIFIER ::= { cmplsTeStdExtMIB 2 } cmplsTunnelAutoBWTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTunnelAutoBWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used in order to manage auto bandwidth data. This table is sparse dependent on the mplsTunnelTable. An entry in this table exists for each mplsTunnelEntry with a mplsTunnelRole of 'head' or 'headTail'. Each row contains auto-bandwidth data for the tunnel identified by the indexes defined later. An entry is created as soon as a 'head' or 'headTail' MPLS TE tunnel is configured in the system." ::= { cmplsTeStdExtMIBObjects 1 } cmplsTunnelAutoBWEntry OBJECT-TYPE SYNTAX CmplsTunnelAutoBWEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row in cmplsTunnelAutoBWTable. There is an entry in this table for each MPLS-TE tunnel with mplsTunnelRole equals to 'head' or 'headTail'." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTunnelAutoBWTable 1 } CmplsTunnelAutoBWEntry ::= SEQUENCE { cmplsTunnelAutoBWStatus INTEGER, cmplsTunnelAutoBWMin Unsigned32, cmplsTunnelAutoBWMax Unsigned32, cmplsTunnelAutoBWAdjThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWAdjThreshBW Unsigned32, cmplsTunnelAutoBWOverflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWOverflowThreshBW Unsigned32, cmplsTunnelAutoBWOverflowLimit Unsigned32, cmplsTunnelAutoBWUnderflowThreshPercs CmplsTunnelBWPercent, cmplsTunnelAutoBWUnderflowThreshBW Unsigned32, cmplsTunnelAutoBWUnderflowLimit Unsigned32, cmplsTunnelAutoBWApplicationFrequency Unsigned32, cmplsTunnelAutoBWCollectionFrequency Unsigned32, cmplsTunnelAutoBWLastAppliedBW Unsigned32, cmplsTunnelAutoBWApplications Counter32, cmplsTunnelAutoBWLastApplicationTrigger INTEGER, cmplsTunnelAutoBWOverflowApplications Counter32, cmplsTunnelAutoBWOverflowOccurrences Counter32, cmplsTunnelAutoBWUnderflowApplications Counter32, cmplsTunnelAutoBWUnderflowOccurrences Counter32, cmplsTunnelAutoBWUnderflowHighestBW Gauge32, cmplsTunnelAutoBWRequested Unsigned32, cmplsTunnelAutoBWSignaled Unsigned32, cmplsTunnelAutoBWCollectOnlyRequested Unsigned32, cmplsTunnelAutoBWHighest Unsigned32, cmplsTunnelAutoBWCollectedSamples Counter32, cmplsTunnelAutoBWJitter Unsigned32, cmplsTunnelAutoBWAppRejectReason INTEGER } cmplsTunnelAutoBWStatus OBJECT-TYPE SYNTAX INTEGER { autoBWDisabled(1), autoBWEnabled(2), autoBWCollectOnlyMode(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the operational status [or mode] of the auto bandwidth algorithm: - autoBWDisabled: The auto-bandwidth algorithm is not running; - autoBWEnabled: The auto-bandwidth algorithm is running; - autoBWCollectOnlyMode: The auto-bandwidth algorithm is running, but the bandwidth applications are disabled;" DEFVAL { autoBWDisabled } ::= { cmplsTunnelAutoBWEntry 1 } cmplsTunnelAutoBWMin OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the minimum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 2 } cmplsTunnelAutoBWMax OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the maximum bandwidth that the auto-bandwidth algorithm can apply to a tunnel when the adjustment threshold is overcome. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 100 } ::= { cmplsTunnelAutoBWEntry 3 } cmplsTunnelAutoBWAdjThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 4 } cmplsTunnelAutoBWAdjThreshBW OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger a new bandwidth application. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 5 } cmplsTunnelAutoBWOverflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 6 } cmplsTunnelAutoBWOverflowThreshBW OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an overflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 7 } cmplsTunnelAutoBWOverflowLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the number of consecutive collections exceeding overflow threshold. If the application period has not completed when a cmplsTunnelAutoBWOverflowLimit overflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 8 } cmplsTunnelAutoBWUnderflowThreshPercs OBJECT-TYPE SYNTAX CmplsTunnelBWPercent MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold percentage that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 10 } ::= { cmplsTunnelAutoBWEntry 9 } cmplsTunnelAutoBWUnderflowThreshBW OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the adjustment threshold bandwidth that needs to be overcome in order to trigger an underflow occurrence. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 10 } cmplsTunnelAutoBWUnderflowLimit OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the number of consecutive collections under the underflow threshold. If the application period has not completed when a cmplsTunnelAutoBWUnderflowLimit underflow has occurred, a new bandwidth will be applied. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 1 } ::= { cmplsTunnelAutoBWEntry 11 } cmplsTunnelAutoBWApplicationFrequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the bandwidth application period. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 12 } cmplsTunnelAutoBWCollectionFrequency OBJECT-TYPE SYNTAX Unsigned32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the sampling period for data rates. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 300 } ::= { cmplsTunnelAutoBWEntry 13 } cmplsTunnelAutoBWLastAppliedBW OBJECT-TYPE SYNTAX Unsigned32 UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the last bandwidth applied by the auto-bandwidth algorithm. It will be set to zero if no bandwidth has been applied yet. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 14 } cmplsTunnelAutoBWApplications OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of auto bandwidths applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 15 } cmplsTunnelAutoBWLastApplicationTrigger OBJECT-TYPE SYNTAX INTEGER { applicationNone(1), applicationPeriodic(2), applicationManual(3), applicationOverflow(4), applicationUnderflow(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the trigger reason for the last bandwidth application. If mplsTunnelInstance is zero this object will be set to 'applicationNone'. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 16 } cmplsTunnelAutoBWOverflowApplications OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of bandwidth applications due to overflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 17 } cmplsTunnelAutoBWOverflowOccurrences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of overflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 18 } cmplsTunnelAutoBWUnderflowApplications OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of bandwidth applications due to underflow occurrences. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 19 } cmplsTunnelAutoBWUnderflowOccurrences OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the number of underflow occurrences since last application period. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 20 } cmplsTunnelAutoBWUnderflowHighestBW OBJECT-TYPE SYNTAX Gauge32 UNITS "kbps" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the highest sample collected during an underflow sequence. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 21 } cmplsTunnelAutoBWRequested OBJECT-TYPE SYNTAX Unsigned32 UNITS "kpbs" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the bandwidth requested by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 22 } cmplsTunnelAutoBWSignaled OBJECT-TYPE SYNTAX Unsigned32 UNITS "kpbs" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the bandwidth signaled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 23 } cmplsTunnelAutoBWCollectOnlyRequested OBJECT-TYPE SYNTAX Unsigned32 UNITS "kpbs" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the bandwidth that would have been requested by the auto-bandwidth algorithm if the auto-bandwidth functionality was enabled. If the collect only mode is enabled, the bandwidth change request will not be executed. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 24 } cmplsTunnelAutoBWHighest OBJECT-TYPE SYNTAX Unsigned32 UNITS "kpbs" MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the highest bandwidth sampled by the auto-bandwidth algorithm. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 25 } cmplsTunnelAutoBWCollectedSamples OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the samples collected since the last auto-bandwidth application. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 26 } cmplsTunnelAutoBWJitter OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the auto-bandwidth application jitter. Jitter is the extra time to be added to the application interval the first time the auto bandwidth is applied. If mplsTunnelInstance is zero this object will be set to zero. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." DEFVAL { 0 } ::= { cmplsTunnelAutoBWEntry 27 } cmplsTunnelAutoBWAppRejectReason OBJECT-TYPE SYNTAX INTEGER { applicationAllowed(1), autoBWDisabled(2), tunnelIsDown(3), tunnelIsFRR(4), tunnelIsBackup(5), tunnelIsLockDown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the reason for the bandwidth application rejection. This object value is not aplicable if cmplsTunnelAutoBWStatus is 'autoBWDisabled'." ::= { cmplsTunnelAutoBWEntry 28 } cmplsTeTunnelReasonTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTeTunnelReasonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used in order to indicate the causes for the notifications." ::= { cmplsTeStdExtMIBObjects 2 } cmplsTeTunnelReasonEntry OBJECT-TYPE SYNTAX CmplsTeTunnelReasonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row in cmplsTunnelReasonTable." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTeTunnelReasonTable 1 } CmplsTeTunnelReasonEntry ::= SEQUENCE { cmplsTunnelReoptReason INTEGER, cmplsTunnelInsuffBWFailedOperation INTEGER, cmplsTunnelPreemptionType INTEGER, cmplsTunnelPreemptionLinkAddrType InetAddressType, cmplsTunnelPreemptionLinkAddr InetAddress, cmplsTunnelReRoutePendingClearReason INTEGER } cmplsTunnelReoptReason OBJECT-TYPE SYNTAX INTEGER { unknown(1), periodicTimerExpiry(2), bandwidthCLIChange(3), bandwidthOverflow(4), bandwidthUnderflow(5), bandwidthAdjustment(6), fastReRoute(7), cliRequest(8), metricTypeChange(9), preferredPathExists(10), poSwitchoverTrigger(11), bandwidthChange(12), autoBandwidth(13), remergeError(14), dueToMaximumMetric(15), pathProtectionSwitchover(16), iEPEnableReoptimization(17), affinityPathVerificationFail(18), softPreemption(19), preferredTreeExists(20), costLimitPathVerificationFail(21), linkupReopt(22), iEPChange(23), poChange(24), destChange(25), bfdSessionTypeChange(26) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the reason of the tunnel reoptimization: - unknown: the reason is not known - periodicTimerExpiry: Periodic Reoptimization - bandwidthCLIChange: the tunnel bandwidth has been changed from CLI - bandwidthOverflow: an auto-bandwidth overflow occurred - bandwidthUnderflow: an auto-bandwidth underflow occured - bandwidthAdjustment: an auto-bandwidth application occured - fastReRoute: a fast re-route occured - cliRequest: User-triggerred - metricTypeChange: tunnel metric type has been changed from CLI - preferredPathExists: preferred-path-exists message received from a downstream node - poSwitchoverTrigger: User-requested path-option switchover - bandwidthChange: bandwidth change - autoBandwidth: Auto Bandwidth - remergeError: Remerge Error - dueToMaximumMetric: Reoptimization due to receiving an LSA with MAX metric - pathProtectionSwitchover: Path Protection Switchover - iEPEnableReoptimization: IEP Enable Reoptimization - affinityPathVerificationFail: Affinity path verification failure - softPreemption: soft preemption (see RFC 5712) - preferredTreeExists: preferred-tree-exists message received from a downstream node - costLimitPathVerificationFail: Cost Limit path verification failure - linkupReopt: link state up - iEPChangeReoptimization: inuse explicit-path change - poChangeReoptimization: inuse path-option change - bfdSessionTypeChange: a bfd session type change occured This object is intended to be included in the trap mplsTunnelReoptimized defined in MPLS-TE-STD-MIB." DEFVAL { unknown } ::= { cmplsTeTunnelReasonEntry 1 } cmplsTunnelInsuffBWFailedOperation OBJECT-TYPE SYNTAX INTEGER { unknown(1), failedToSetup(2), failedToReoptimize(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates whether the tunnel could not be setup or reoptimized because of insufficient bandwidth: - unknown: the reason is not known - failedToSetup: insufficient bandwidth during initial setup - failedToReoptimize: insufficient bandwidth during reoptimization" DEFVAL { unknown } ::= { cmplsTeTunnelReasonEntry 2 } cmplsTunnelPreemptionType OBJECT-TYPE SYNTAX INTEGER { unknown(1), hardPreemption(2), softPreemption(3), frrSoftPreemption(4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates LSP Preemption type of this LSP: - unknown: the type is not known - hardPreemption: the preempted LSP resources are freed immediately; the LSP is broken immediately and the traffic is disrupted. - softPreemption: the resources release pending on the reoptimization of this LSP. The head of the LSP reroutes the traffic before the LSP is broken. - frrSoftPreemption: similar to softPreemption. In this case the traffic of the soft preempted LSP is switched to the backup. See: Farrel, A., Interim Report on MPLS Pre-emption, draft-farrel-mpls-preemption-interim-00.txt, work in progress" ::= { cmplsTeTunnelReasonEntry 3 } cmplsTunnelPreemptionLinkAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the address type of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not enough bandwidth for it causing this LSP to be preempted (removed) from this link: - unknown: the object cmplsTunnelPreemptionLinkAddr does not contain any address - ipv4: the object cmplsTunnelPreemptionLinkAddr contains the IPv4 address - ipv6: the object cmplsTunnelPreemptionLinkAddr contains the IPv6 address" ::= { cmplsTeTunnelReasonEntry 4 } cmplsTunnelPreemptionLinkAddr OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the address of the link where the preemption occurs - another, higher priority LSP is being admitted on this link and there is not enough bandwidth for it causing this LSP to be preempted (removed) from this link." ::= { cmplsTeTunnelReasonEntry 5 } cmplsTunnelReRoutePendingClearReason OBJECT-TYPE SYNTAX INTEGER { unknown(1), reoptimized(2), reinstated(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object indicates the reason why the tunnel is not longer in the reroute pending state: - unknown: the reason is unknown - reoptimized: the tunnel has been reoptimized - reinstated: the tunnel has been reinstated" ::= { cmplsTeTunnelReasonEntry 6 } cmplsTeTunnelFailReasonTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTeTunnelFailReasonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used in order to indicate the causes for the MPLS TE tunnel failure notifications." ::= { cmplsTeStdExtMIBObjects 3 } cmplsTeTunnelFailReasonEntry OBJECT-TYPE SYNTAX CmplsTeTunnelFailReasonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row in the cmplsTeTunnelFailReasonTable." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId, mplsTunnelARHopListIndex } ::= { cmplsTeTunnelFailReasonTable 1 } CmplsTeTunnelFailReasonEntry ::= SEQUENCE { cmplsTeFailReasonType INTEGER, cmplsTeFailReason Integer32, cmplsTeFailReasonRev INTEGER } cmplsTeFailReasonType OBJECT-TYPE SYNTAX INTEGER { unknown(1), bfd(2), generalTe(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the type (category) of fail reason." ::= { cmplsTeTunnelFailReasonEntry 1 } cmplsTeFailReason OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This object indicates specific fail reason value based on the fail reason type indicated by cmplsTeFailReasonType. Fail Reason Type Fail Reason Value Type ---------------- ----------------------- bfd(2) CiscoBfdDiag generalTe(3) CmplsTeTunnelDiag This object is replaced by cmplsTeFailReasonRev" ::= { cmplsTeTunnelFailReasonEntry 2 } cmplsTeFailReasonRev OBJECT-TYPE SYNTAX INTEGER { noDiagnostic(0), controlDetectionTimeExpired(1), echoFunctionFailed(2), neighborSignaledSessionDown(3), forwardingPlaneReset(4), pathDown(5), concatenatedPathDown(6), administrativelyDown(7), reverseConcatenatedPathDown(8), unknown(9), bfdSessionBringupTimeout(21) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This object provieds more deails on fail reason. cmplsTeFailReason values for reasonType bfd(2) mirror the CiscoBfdDiag values: - noDiagnostic No bfd diagnostic info - controlDetectionTimeExpired Control Detection Timer Expired - echoFunctionFailed Echo Function Failed - neighborSignaledSessionDown Neighbor Signaled Session Down - forwardingPlaneReset Forwarding Plane Reset - pathDown Path Down - concatenatedPathDown Concatenated Path Down - administrativelyDown Administratively Down - reverseConcatenatedPathDown Reverse Concatenated Path Down - unknown Unknown error code cmplsTeFailReason values for reasonType generalTe(3) mirror the CmplsTeTunnelDiag values: - unknown Unknown error code - bfdSessionBringupTimeout bfd session failed to come up before timeout" ::= { cmplsTeTunnelFailReasonEntry 3 } cmplsTunnelLoadshareTable OBJECT-TYPE SYNTAX SEQUENCE OF CmplsTunnelLoadshareEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used in order to manage load data." ::= { cmplsTeStdExtMIBObjects 4 } cmplsTunnelLoadshareEntry OBJECT-TYPE SYNTAX CmplsTunnelLoadshareEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A conceptual row in cmplsTunnelLoadshareTable. There is an entry in this table for each MPLS-TE tunnel." INDEX { mplsTunnelIndex, mplsTunnelInstance, mplsTunnelIngressLSRId, mplsTunnelEgressLSRId } ::= { cmplsTunnelLoadshareTable 1 } CmplsTunnelLoadshareEntry ::= SEQUENCE { cmplsTunnelLoadShare Unsigned32 } cmplsTunnelLoadShare OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Load-share as defined by the bandwidth attribute (default) or explicitly configured using the load-share command under tunnel configuration." DEFVAL { 0 } ::= { cmplsTunnelLoadshareEntry 1 } -- Objects reflecting TE Global variables -- cmplsTeStdExtMIBObjectsGlobal OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBObjects 5 } cmplsTeLoadshareBalance OBJECT-TYPE SYNTAX INTEGER { equal(0), unequal(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the load-share balance is equal or unequal." DEFVAL { equal } ::= { cmplsTeStdExtMIBObjectsGlobal 1 } cmplsTunnelPreempt NOTIFICATION-TYPE OBJECTS { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, cmplsTunnelPreemptionLinkAddr } STATUS current DESCRIPTION "This notification is generated when a MPLS TE tunnel is preempted." ::= { cmplsTeStdExtMIBNotifs 1 } cmplsTunnelInsuffBW NOTIFICATION-TYPE OBJECTS { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelInsuffBWFailedOperation } STATUS current DESCRIPTION "This notification is generated when a MPLS TE tunnel could not be setup or reoptimized." ::= { cmplsTeStdExtMIBNotifs 2 } cmplsTunnelReRoutePending NOTIFICATION-TYPE OBJECTS { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName } STATUS current DESCRIPTION "This notification is generated when re-route is required for the tunnel." ::= { cmplsTeStdExtMIBNotifs 3 } cmplsTunnelReRoutePendingClear NOTIFICATION-TYPE OBJECTS { mplsTunnelAdminStatus, mplsTunnelOperStatus, mplsTunnelName, cmplsTunnelReRoutePendingClearReason } STATUS current DESCRIPTION "This notification is generated when tunnel no longer needs to be re-routed." ::= { cmplsTeStdExtMIBNotifs 4 } cmplsTunnelBringupFail NOTIFICATION-TYPE OBJECTS { mplsTunnelName, cmplsTeFailReasonType } STATUS current DESCRIPTION "This notification is generated when MPLS TE tunnel failed to come up" ::= { cmplsTeStdExtMIBNotifs 5 } cmplsTeStdExtMIBCompliances OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 1 } cmplsTeStdExtMIBGroups OBJECT IDENTIFIER ::= { cmplsTeStdExtMIBConform 2 } cmplsTeStdExtMIBCompliance MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This is the main compliance statement for the MIB." MODULE -- this module GROUP cmplsTeStdExtMIBAutoBWOptionalGroup DESCRIPTION "Optional group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBAutoBWObjectGroup DESCRIPTION "main objects group for routers implementing auto-bandwidth feature." ::= { cmplsTeStdExtMIBCompliances 1 } cmplsTeStdExtMIBCompliancesRev1 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This is the main compliance statement for the MIB. Adding the extended traps." MODULE -- this module GROUP cmplsTeStdExtMIBAutoBWOptionalGroup DESCRIPTION "Optional group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBAutoBWObjectGroup DESCRIPTION "main objects group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBTrapGroup DESCRIPTION "Extended MPLS TE Tunnel Traps" GROUP cmplsTeStdExtMIBTrapObjectsGroup DESCRIPTION "Extended MPLS TE Tunnel Traps Objects" ::= { cmplsTeStdExtMIBCompliances 2 } cmplsTeStdExtMIBComplianceRev2 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This is the main compliance statement for the MIB" MODULE -- this module GROUP cmplsTeStdExtMIBAutoBWOptionalGroup DESCRIPTION "Optional group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBAutoBWObjectGroup DESCRIPTION "main objects group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBTrapGroup DESCRIPTION "Extended MPLS TE Tunnel Traps" GROUP cmplsTeStdExtMIBTrapObjectsGroupRev1 DESCRIPTION "Extended MPLS TE Tunnel Traps Objects" ::= { cmplsTeStdExtMIBCompliances 3 } cmplsTeStdExtMIBComplianceRev3 MODULE-COMPLIANCE STATUS deprecated DESCRIPTION "This is the main compliance statement for the MIB" MODULE -- this module GROUP cmplsTeStdExtMIBAutoBWOptionalGroup DESCRIPTION "Optional group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBAutoBWObjectGroup DESCRIPTION "main objects group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBTrapGroup DESCRIPTION "Extended MPLS TE Tunnel Traps" GROUP cmplsTeStdExtMIBTrapObjectsGroupRev1 DESCRIPTION "Extended MPLS TE Tunnel Traps Objects" GROUP cmplsTeStdExtMIBFailTeTrapGroup DESCRIPTION "BFD over TE LSP traps" GROUP cmplsTeStdExtMIBFailTeTrapObjectsGroup DESCRIPTION "Objects for BFD over TE LSP traps" ::= { cmplsTeStdExtMIBCompliances 4 } cmplsTeStdExtMIBComplianceRev4 MODULE-COMPLIANCE STATUS current DESCRIPTION "This is the main compliance statement for the MIB" MODULE -- this module GROUP cmplsTeStdExtMIBAutoBWOptionalGroup DESCRIPTION "Optional group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBAutoBWObjectGroup DESCRIPTION "main objects group for routers implementing auto-bandwidth feature." GROUP cmplsTeStdExtMIBTrapGroup DESCRIPTION "Extended MPLS TE Tunnel Traps" GROUP cmplsTeStdExtMIBTrapObjectsGroupRev1 DESCRIPTION "Extended MPLS TE Tunnel Traps Objects" GROUP cmplsTeStdExtMIBFailTeTrapGroup DESCRIPTION "BFD over TE LSP traps" GROUP cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 DESCRIPTION "Objects for BFD over TE LSP traps" OBJECT cmplsTeFailReasonType MIN-ACCESS accessible-for-notify DESCRIPTION "Read access is not required." GROUP cmplsTeStdExtMIBLoadShareObjectsGroup DESCRIPTION "Loadshare TE Objects" ::= { cmplsTeStdExtMIBCompliances 5 } -- Units of Conformance cmplsTeStdExtMIBAutoBWObjectGroup OBJECT-GROUP OBJECTS { cmplsTunnelAutoBWStatus, cmplsTunnelAutoBWMin, cmplsTunnelAutoBWMax, cmplsTunnelAutoBWAdjThreshPercs, cmplsTunnelAutoBWAdjThreshBW, cmplsTunnelAutoBWApplicationFrequency, cmplsTunnelAutoBWCollectionFrequency, cmplsTunnelAutoBWLastAppliedBW, cmplsTunnelAutoBWApplications, cmplsTunnelAutoBWLastApplicationTrigger, cmplsTunnelAutoBWOverflowApplications, cmplsTunnelAutoBWOverflowOccurrences, cmplsTunnelAutoBWUnderflowApplications, cmplsTunnelAutoBWUnderflowOccurrences, cmplsTunnelAutoBWUnderflowHighestBW, cmplsTunnelAutoBWRequested, cmplsTunnelAutoBWSignaled, cmplsTunnelAutoBWCollectOnlyRequested, cmplsTunnelAutoBWHighest, cmplsTunnelAutoBWCollectedSamples, cmplsTunnelAutoBWAppRejectReason } STATUS current DESCRIPTION "This contains the main MPLS TE extensions groups." ::= { cmplsTeStdExtMIBGroups 1 } cmplsTeStdExtMIBAutoBWOptionalGroup OBJECT-GROUP OBJECTS { cmplsTunnelAutoBWOverflowThreshPercs, cmplsTunnelAutoBWOverflowThreshBW, cmplsTunnelAutoBWOverflowLimit, cmplsTunnelAutoBWUnderflowThreshPercs, cmplsTunnelAutoBWUnderflowThreshBW, cmplsTunnelAutoBWUnderflowLimit, cmplsTunnelAutoBWJitter } STATUS current DESCRIPTION "This contains the optional MPLS TE extensions groups." ::= { cmplsTeStdExtMIBGroups 2 } cmplsTeStdExtMIBTrapObjectsGroup OBJECT-GROUP OBJECTS { cmplsTunnelReoptReason, cmplsTunnelInsuffBWFailedOperation, cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, cmplsTunnelPreemptionLinkAddr } STATUS deprecated DESCRIPTION "This contains the MPLS TE extended traps objects. This object is replaced by cmplsTeStdExtMIBTrapObjectsGroupRev1" ::= { cmplsTeStdExtMIBGroups 3 } cmplsTeStdExtMIBTrapObjectsGroupRev1 OBJECT-GROUP OBJECTS { cmplsTunnelReoptReason, cmplsTunnelInsuffBWFailedOperation, cmplsTunnelPreemptionType, cmplsTunnelPreemptionLinkAddrType, cmplsTunnelPreemptionLinkAddr, cmplsTunnelReRoutePendingClearReason } STATUS current DESCRIPTION "This contains the optional MPLS TE extensions groups." ::= { cmplsTeStdExtMIBGroups 4 } cmplsTeStdExtMIBTrapGroup NOTIFICATION-GROUP NOTIFICATIONS { cmplsTunnelPreempt, cmplsTunnelInsuffBW, cmplsTunnelReRoutePending, cmplsTunnelReRoutePendingClear } STATUS current DESCRIPTION "This contains the MPLS TE extended traps." ::= { cmplsTeStdExtMIBGroups 5 } cmplsTeStdExtMIBFailTeTrapGroup NOTIFICATION-GROUP NOTIFICATIONS { cmplsTunnelBringupFail } STATUS current DESCRIPTION "This contains the MPLS TE extended traps related to BFD over TE LSP." ::= { cmplsTeStdExtMIBGroups 6 } cmplsTeStdExtMIBFailTeTrapObjectsGroup OBJECT-GROUP OBJECTS { cmplsTeFailReasonType, cmplsTeFailReason } STATUS deprecated DESCRIPTION "This contains the MPLS TE extended traps objects related to BFD over TE LSP. This object is replaced by cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1" ::= { cmplsTeStdExtMIBGroups 7 } cmplsTeStdExtMIBLoadShareObjectsGroup OBJECT-GROUP OBJECTS { cmplsTunnelLoadShare, cmplsTeLoadshareBalance } STATUS current DESCRIPTION "This contains the MPLS TE extended objects related to TE loadshare." ::= { cmplsTeStdExtMIBGroups 8 } cmplsTeStdExtMIBFailTeTrapObjectsGroupRev1 OBJECT-GROUP OBJECTS { cmplsTeFailReasonType, cmplsTeFailReasonRev } STATUS current DESCRIPTION "This contains the MPLS TE extended traps objects related to BFD over TE LSP." ::= { cmplsTeStdExtMIBGroups 9 } END