-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00 -- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved -- $RCSfile: mibcapi,v $ -- $Revision: 1.28 $ BIANCA-BRICK-CAPI-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, enterprises FROM RFC1155-SMI DisplayString FROM RFC1158-MIB BitValue, HexValue FROM BINTEC-MIB OBJECT-TYPE FROM RFC-1212; bintec OBJECT IDENTIFIER ::= { enterprises 272 } bibo OBJECT IDENTIFIER ::= { bintec 4 } capi OBJECT IDENTIFIER ::= { bibo 7 } -- CAPI Group -- Management Information for the CAPI Subsystem of the BIANCA/BRICK capiApplTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiApplEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiApplTable contains information for all currently registered CAPI 1.1 and CAPI 2.0 applications, and their respective CAPI_REGISTER information. Creating entries: Entries are created automatically by the system. After receiving an appropriate CAPI_REGISTER call, the system 'registers' the application, and assigns it a unique capiApplNumber. Deleting entries: Once an application releases, entries are automatically removed by the system." ::= { capi 1 } capiApplEntry OBJECT-TYPE SYNTAX CapiApplEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiApplNumber } ::= { capiApplTable 1 } CapiApplEntry ::= SEQUENCE { capiApplNumber INTEGER, capiApplVersion INTEGER, capiApplByteOrder INTEGER, capiApplRegMsgCnt INTEGER, capiApplRegLevel3Cnt INTEGER, capiApplRegDblkCnt INTEGER, capiApplRegDblkSize INTEGER, capiApplInfoStr DisplayString } capiApplNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Identification number of the registered application." ::= { capiApplEntry 1 } capiApplVersion OBJECT-TYPE SYNTAX INTEGER { capi11(1), capi20(2) } ACCESS read-only STATUS mandatory DESCRIPTION "The version number of the registered application." DEFVAL { capi20 } ::= { capiApplEntry 2 } capiApplByteOrder OBJECT-TYPE SYNTAX INTEGER { little-endian(1), big-endian(2), undef(3) } ACCESS read-only STATUS mandatory DESCRIPTION "The byte order used by the application." DEFVAL { little-endian } ::= { capiApplEntry 3 } capiApplRegLevel3Cnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CAPI_REGISTER: The number of level 3 connections this application accepts." ::= { capiApplEntry 4 } capiApplRegMsgCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CAPI_REGISTER: The number of registered CAPI messages this application accepts." ::= { capiApplEntry 5 } capiApplRegDblkCnt OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CAPI_REGISTER: The number of registered B3 data blocks this application accepts." ::= { capiApplEntry 6 } capiApplRegDblkSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "CAPI_REGISTER: The size of registered B3 data blocks this application accepts." ::= { capiApplEntry 7 } capiApplInfoStr OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Information string of CAPI instance: IP address and TCP port of connecting system and user name if any." ::= { capiApplEntry 8 } capiListenTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiListenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiListenTable contains the listen settings for each CAPI application. Creating entries: Entries can only be created by the system and is performed automatically upon receiving a CAPI_LISTEN_REQ message. Deleting entries: Entries are automatically removed by the system once the application releases." ::= { capi 2 } capiListenEntry OBJECT-TYPE SYNTAX CapiListenEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiListenApplication } ::= { capiListenTable 1 } CapiListenEntry ::= SEQUENCE { capiListenApplication INTEGER, capiListenController HexValue, capiListenServiceMask HexValue, capiListenEazMask HexValue, capiListenInfoMask HexValue, capiListenCipMask HexValue, capiListenCipMask2 HexValue } capiListenApplication OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The application-number (capiApplNumber)." ::= { capiListenEntry 1 } capiListenController OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The ISDN controller number. This value refers to the isdnStkNumber." ::= { capiListenEntry 2 } capiListenServiceMask OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The bit mask of CAPI 1.1 listen services. Specifies which 1TR6 services to listen for (CAPI 1.1 only)." ::= { capiListenEntry 3 } capiListenEazMask OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The bit mask of CAPI 1.1 listen-EAZs (CAPI 1.1 only)." ::= { capiListenEntry 4 } capiListenInfoMask OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The bit mask of the CAPI 1.1/2.0 listen InfoMask setting. The purpose of infomask is to specify the type of information for a physical connection or controller which will be provided by CAPI." ::= { capiListenEntry 5 } capiListenCipMask OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The bit mask of CAPI 2.0 listen CIPMask. The purpose of the CIPMask parameter is to select basic classes of incoming calls. CAPI 2.0 applications only." ::= { capiListenEntry 6 } capiListenCipMask2 OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The bit mask of CAPI 2.0 listen CIPMask." ::= { capiListenEntry 7 } capiPlciTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiPlciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiPlciTable contains information for each currently connected CAPI application (i.e. has a Physical Link Connection Identifier associated with it). Creating entries: Entries can only be made by the system. Upon receiving a CAPI_CONNECT_REQ (or CAPI_CONNECT_IND) message, the system assigns a unique PLCI (capiPlciNumber) and an entry is made. Deleting entries: Entries are automatically deleted by the system once a CAPI_DISCONNECT_RESP message is received." ::= { capi 3 } capiPlciEntry OBJECT-TYPE SYNTAX CapiPlciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiPlciNumber } ::= { capiPlciTable 1 } CapiPlciEntry ::= SEQUENCE { capiPlciNumber HexValue, capiPlciApplication INTEGER, capiPlciController HexValue, capiPlciState INTEGER, capiPlciSelectB2Proto INTEGER, capiPlciSelectB2Dlpd OCTET STRING, capiPlciSelectB3Proto INTEGER, capiPlciSelectB3Ncpd OCTET STRING, capiPlciB1Proto INTEGER, capiPlciB1Config OCTET STRING, capiPlciB2Proto INTEGER, capiPlciB2Config OCTET STRING, capiPlciB3Proto INTEGER, capiPlciB3Config OCTET STRING, capiPlciInfoMask HexValue, capiPlciCipValue INTEGER } capiPlciNumber OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION " The PLCI (physical link connection identifier) of the application." ::= { capiPlciEntry 1 } capiPlciApplication OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The application-number (capiApplNumber)." ::= { capiPlciEntry 2 } capiPlciController OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The ISDN controller number. This value refers to the isdnStkNumber." ::= { capiPlciEntry 3 } capiPlciState OBJECT-TYPE SYNTAX INTEGER { p-0(1), p-1(2), p-2(3), p-3(4), p-4(5), p-5(6), p-6(7), p-7(8), p-act(9) } ACCESS read-only STATUS mandatory DESCRIPTION "The current link state as described in the CAPI state diagram." DEFVAL { p-0 } ::= { capiPlciEntry 4 } capiPlciSelectB2Proto OBJECT-TYPE SYNTAX INTEGER { undef(1), x75(2), hdlccrc(3), trans(4), sdlc(5), x75btx(6), fax(7), lapd(8), v110trans(9), v110sdlc(10), v110x75(11), txonly(12), modem(241), v110sync(242) } ACCESS read-only STATUS mandatory DESCRIPTION "The current B2 protocol setting (CAPI 1.1 applications only)." DEFVAL { undef } ::= { capiPlciEntry 5 } capiPlciSelectB2Dlpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current B2 protocol descriptor. DLPD = data link protocol descriptor (CAPI 1.1 applications only)." ::= { capiPlciEntry 6 } capiPlciSelectB3Proto OBJECT-TYPE SYNTAX INTEGER { undef(1), t70nl(2), iso8208(3), t90(4), trans(5), t30(6) } ACCESS read-only STATUS mandatory DESCRIPTION "Current B3 protocol setting (CAPI 1.1 applications only)." DEFVAL { undef } ::= { capiPlciEntry 7 } capiPlciSelectB3Ncpd OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The current B3 Ncpd setting. NCPD = network control protocol descriptor (CAPI 1.1 applications only)." ::= { capiPlciEntry 8 } capiPlciB1Proto OBJECT-TYPE SYNTAX INTEGER { undef(1), hdlc(2), trans(3), v110trans(4), v110hdlc(5), faxg3(6), hdlcinv(7), hdlc56(8), modemneg(9), modemasync(10), modemsync(11) } ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B1 protocol setting." DEFVAL { undef } ::= { capiPlciEntry 9 } capiPlciB1Config OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B1 protocol configuration setting." ::= { capiPlciEntry 10 } capiPlciB2Proto OBJECT-TYPE SYNTAX INTEGER { undef(1), x75(2), trans(3), sdlc(4), lapd(5), t30(6), ppp(7), transerr(8), modem(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B2 protocol setting." DEFVAL { undef } ::= { capiPlciEntry 11 } capiPlciB2Config OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B2 protocol configuration setting." ::= { capiPlciEntry 12 } capiPlciB3Proto OBJECT-TYPE SYNTAX INTEGER { undef(1), trans(2), t90(3), iso8208(4), x25dce(5), t30(6), t30ext(7), modem(9) } ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B3 protocol setting." DEFVAL { undef } ::= { capiPlciEntry 13 } capiPlciB3Config OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Current CAPI 2.0 B3 protocol configuration setting." ::= { capiPlciEntry 14 } capiPlciCipValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The current CIPValue setting." ::= { capiPlciEntry 15 } capiPlciInfoMask OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The current InfoMask setting." ::= { capiPlciEntry 16 } capiNcciTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiNcciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiNcciTable contains information for each CAPI NCCI (network control connection identifier). An NCCI describes a logical connection on level 3. Several NCCIs operating on the same PLCI may exist. Creating entries: As soon as a CAPI_CONNECT_B3_REQ (or CAPI_CONNECT_B3_IND) message is received, the system creates an entry by assigning the application a unique capiNcciNumber. Deleting entries: Entries are automatically deleted by the system once a CAPI_DISCONNECT_B3_RESP message is received." ::= { capi 4 } capiNcciEntry OBJECT-TYPE SYNTAX CapiNcciEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiNcciNumber } ::= { capiNcciTable 1 } CapiNcciEntry ::= SEQUENCE { capiNcciNumber HexValue, capiNcciApplication INTEGER, capiNcciPlci HexValue, capiNcciState INTEGER } capiNcciNumber OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The NCCI number assigned by the system." ::= { capiNcciEntry 1 } capiNcciApplication OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The application number (capiApplNumber)." ::= { capiNcciEntry 2 } capiNcciPlci OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The CAPI PLCI number (capiPlciNumber)." ::= { capiNcciEntry 3 } capiNcciState OBJECT-TYPE SYNTAX INTEGER { n-0(1), n-1(2), n-2(3), n-3(4), n-4(5), n-5(6), n-act(7) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the NCCI, as described in the CAPI state diagram." DEFVAL { n-0 } ::= { capiNcciEntry 4 } capiInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiInfoTable contains the last 10 CAPI info codes and their message identifiers for where the error occured. The most recent message is at inx 09 with older messages rolling off the top of the table, i.e. inx 00. Creating entries: Entries are created automatically by the system once a CAPI info code is received by a registered application. Deleting entries: Entries are removed automatically by the system." ::= { capi 5 } capiInfoEntry OBJECT-TYPE SYNTAX CapiInfoEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiInfoApplication } ::= { capiInfoTable 1 } CapiInfoEntry ::= SEQUENCE { capiInfoApplication INTEGER, capiInfoPlci HexValue, capiInfoNcci HexValue, capiInfoC1Command INTEGER, capiInfoC2Command INTEGER, capiInfoSubCommand INTEGER, capiInfoNumber HexValue } capiInfoApplication OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The application number (capiApplNumber)." ::= { capiInfoEntry 1 } capiInfoPlci OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The CAPI PLCI number (capiPlciNumber)." ::= { capiInfoEntry 2 } capiInfoNcci OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The NCCI number (capiNcciNumber)." ::= { capiInfoEntry 3 } capiInfoC1Command OBJECT-TYPE SYNTAX INTEGER { resetb3(1), connect(2), conact(3), disc(4), listen(5), param(6), info(7), data(8), conninfo(9), dtmf(10), selb2(64), selb3(128), listenb3(129), conb3(130), conb3act(131), discb3(132), b3param(133), datab3(134), handset(135) } ACCESS read-only STATUS mandatory DESCRIPTION "The CAPI 1.1 command where the info occurred." DEFVAL { info } ::= { capiInfoEntry 4 } capiInfoC2Command OBJECT-TYPE SYNTAX INTEGER { alert(1), connect(2), conact(3), disc(4), listen(5), info(8), selectb(65), facility(128), conb3(130), conb3act(131), discb3(132), datab3(134), resetb3(135), conb3t90(136), manufact(255) } ACCESS read-only STATUS mandatory DESCRIPTION "The CAPI 2.0 command where the info occurred." DEFVAL { info } ::= { capiInfoEntry 5 } capiInfoSubCommand OBJECT-TYPE SYNTAX INTEGER { req(1), conf(2), ind(3), resp(4) } ACCESS read-only STATUS mandatory DESCRIPTION "The CAPI 1.1/2.0 subcommand." DEFVAL { ind } ::= { capiInfoEntry 6 } capiInfoNumber OBJECT-TYPE SYNTAX HexValue ACCESS read-only STATUS mandatory DESCRIPTION "The info value as specified in the CAPI 1.1/2.0 specification. See the Software Reference Manual for a listing of CAPI 1.1 and CAPI 2.0 info values." ::= { capiInfoEntry 7 } capiConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The capiConfigTable contains configuration information for each ISDN stack. Setting these fields is optional, and is not required. Creating entries: Entries are created automatically by the system when a new ISDN stack is initialised in the isdnStkTable. Deleting entries: An entry can be removed by assigning the value `delete' to its capiConfigFaxG3RcvSpeed object. It can be removed only if there is no entry with it's capiConfigStkNumber in the isdnStkTable." ::= { capi 6 } capiConfigEntry OBJECT-TYPE SYNTAX CapiConfigEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiConfigStkNumber } ::= { capiConfigTable 1 } CapiConfigEntry ::= SEQUENCE { capiConfigStkNumber INTEGER, capiConfigFaxG3RcvSpeed INTEGER, capiConfigFaxG3ECM INTEGER, capiConfigFaxG3Header INTEGER, capiConfigVoiceCoding INTEGER, capiConfigSendAlerting INTEGER, capiConfigV42bis INTEGER, capiConfigModemDefault INTEGER, capiConfigFaxModulation INTEGER, capiConfigFax12000 INTEGER, capiConfigFaxTXLevel INTEGER } capiConfigStkNumber OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-only STATUS mandatory DESCRIPTION "The isdnStkNumber this configuration belongs to." ::= { capiConfigEntry 1 } capiConfigFaxG3RcvSpeed OBJECT-TYPE SYNTAX INTEGER { r4800(1), r7200(2), r9600(3), r14400(4), maximum(5), not-available(6), delete(7) } ACCESS read-write STATUS mandatory DESCRIPTION "The G3 facsimile receive speed. For CM-EBRI this should be set to maximum. Set this field to `delete' to remove this entry. The entry can be deleted only if there is no entry with it's capiConfigStkNumber in the isdnStkTable." DEFVAL { maximum } ::= { capiConfigEntry 2 } capiConfigFaxG3ECM OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), not-available(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether ECM (error correction mode) should be used for G3 facsimile transmissions." DEFVAL { on } ::= { capiConfigEntry 3 } capiConfigFaxG3Header OBJECT-TYPE SYNTAX INTEGER { logo-header(1), no-logo(2), no-header(3), not-available(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the header-line and logo ('BIANCA/FAX'), should appear on outgoing facsimiles. The value 'logo_header' allows the header-line and the logo to be printed on the top of each page." DEFVAL { logo-header } ::= { capiConfigEntry 4 } capiConfigVoiceCoding OBJECT-TYPE SYNTAX INTEGER { normal(1), reverse(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Switches the bit order for voice-data." DEFVAL { reverse } ::= { capiConfigEntry 5 } capiConfigSendAlerting OBJECT-TYPE SYNTAX INTEGER { never(1), ever(2), voice-only(3) } ACCESS read-write STATUS mandatory DESCRIPTION "For CAPI 1.1 this specifies when the CAPI server should send alert messages for incoming calls." DEFVAL { voice-only } ::= { capiConfigEntry 6 } capiConfigV42bis OBJECT-TYPE SYNTAX INTEGER { on(1), off(2), not-available(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether V.42bis data compression should be used. If data compression is activated here,the receiving or sending side is first queried whether it supports data compression. The BRICK supports V.42bis data compression using up to 2 B-channels." DEFVAL { off } ::= { capiConfigEntry 7 } capiConfigModemDefault OBJECT-TYPE SYNTAX INTEGER { modem-profile-1(1), modem-profile-2(2), modem-profile-3(3), modem-profile-4(4), modem-profile-5(5), modem-profile-6(6), modem-profile-7(7), modem-profile-8(8)} ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the modem profile of the mdmProfileTable which contains the default modem parameters to use for modem connections." DEFVAL { modem-profile-1 } ::= { capiConfigEntry 8 } capiConfigFaxModulation OBJECT-TYPE SYNTAX INTEGER { v17(1), v33(2), v29(3), v17s(5), v33s(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the default transmission protocol for fax. - v17 max. 14400 Bps new standard - v33 max. 14000 Bps early standard - v29 max. 9600 Bps fax standard - v17s v17 with Swiss capability - v33s v33 with Swiss capability" DEFVAL { v17 } ::= { capiConfigEntry 9 } capiConfigFax12000 OBJECT-TYPE SYNTAX INTEGER { on(1), off(2)} ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the 12000Bps Mode for fax transmission. A lot of fax receivers have problems with this tranmission mode. Default value is off" DEFVAL { off } ::= { capiConfigEntry 10 } capiConfigFaxTXLevel OBJECT-TYPE SYNTAX INTEGER { db0(1), db3(2),db6(3),db9(4),db12(5),db15(6)} ACCESS read-write STATUS mandatory DESCRIPTION "Set the transmit level to -x dB db0 = 0dB, db3 = -3dB. In Germany -6dB (db6) is normally used for facsimile transmission." DEFVAL { db6 } ::= { capiConfigEntry 11 } capiMultiControllerTable OBJECT-TYPE SYNTAX SEQUENCE OF CapiMultiControllerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains mappings between controller numbers used by CAPI applications and the ISDN stacks available on the BRICK (i.e., the Number field of the isdnStkTable). The Version field specifies whether an entry applies to CAPI 1.1 or CAPI 2.0 applications. If a CAPI 1.1 entry is not defined, CAPI 1.1 applications can only use isdnStkNumber N if N is the controller number requested by the application. If a CAPI 2.0 entry is not defined, CAPI 2.0 applications can only use isdnStkNumber N-1 if N is the controller number requested by the application. Creating entries: Entries are created by assigning a value to the capiControllerNumber object. Deleting entries: An entry can be removed by assigning the value `delete' to its capiControllerVersion object." ::= { capi 7 } capiMultiControllerEntry OBJECT-TYPE SYNTAX CapiMultiControllerEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "" INDEX { capiControllerNumber } ::= { capiMultiControllerTable 1 } CapiMultiControllerEntry ::= SEQUENCE { capiControllerNumber INTEGER, capiControllerStkMask BitValue, capiControllerVersion INTEGER } capiControllerNumber OBJECT-TYPE SYNTAX INTEGER (0..31) ACCESS read-write STATUS mandatory DESCRIPTION "The controller number requested by the CAPI application." ::= { capiMultiControllerEntry 1 } capiControllerStkMask OBJECT-TYPE SYNTAX BitValue ACCESS read-write STATUS mandatory DESCRIPTION "This binary number defines the ISDN stack(s) to use for the specified CAPI 1.1 or CAPI 2.0 applications. For example; `Number=1 StkMask=0b1111 Version=capi20' means: allow CAPI 2.0 applications requesting ISDN controller 1 to use the ISDN stacks with IsdnStkNumber 0 - 3 on the BRICK." -- DEFVAL { 'FFFFFFFF'H } DEFVAL { 4294967295 } ::= { capiMultiControllerEntry 2 } capiControllerVersion OBJECT-TYPE SYNTAX INTEGER { capi11(1), capi20(2), delete(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies which CAPI applications (CAPI version 1.1, or 2.0) this entry applies to. Set this field to `delete' to delete this entry." DEFVAL { capi11 } ::= { capiMultiControllerEntry 3 } capiAdminStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable CAPI" DEFVAL { enable } ::= { capi 9 } capiTcpNoDelay OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or Disable TCP Nagle Algorithm for CAPI. disable: Normal operation with Nagle support. enable : Disable Nagle TCP Algorithm. Enable TcpNoDelay increases Network load and decrease delay of TCP packages. On CAPI Applications with small Data packages this option may increase transmission rate." DEFVAL { disable } ::= { capi 10 } capiFaxG3Header OBJECT-TYPE SYNTAX INTEGER { logo-header(1), no-logo(2), no-header(3), not-available(4), specify(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the header-line and logo ('BIANCA/FAX'), should appear on outgoing facsimiles. The value 'logo_header' allows the header-line and the logo to be printed on the top of each page." DEFVAL { specify } ::= { capi 11 } capiX25DefWinSize OBJECT-TYPE SYNTAX INTEGER (1..7) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the X.25 default Windowsize used in ISO8208 (X.25 DTE <-> DTE) Filetransferprotocol. Applications such as OFTP normally uses 7 but some Applications did not use X.25 negotiation, so the CAPI uses here a default from 2 and the connection is closed by a X.25 Reset. Setting this value to 7 is not standard but useful for the customer to avoid this error." DEFVAL { 2 } ::= { capi 12 } END