-- ***************************************************************** -- INFINERA-TP-SDHCLIENTCTP-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-TP-SDHCLIENTCTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter64 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF DisplayString, TruthValue FROM SNMPv2-TC ifIndex FROM IF-MIB InfnServiceType,InfnEnableDisable,InfnServiceMode, InfnSMQ, InfnClientAction, InfnLoopbackType, InfnJ0TraceMode, InfnJ0MessageCompliance, InfnPmHistStatsControl FROM INFINERA-TC-MIB terminationPoint FROM INFINERA-REG-MIB; sdhClientCtpMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "Infinera" CONTACT-INFO "Infinera 1322 Bordeaux Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION " " REVISION "200810200000Z" DESCRIPTION "First Version" ::= { terminationPoint 15 } sdhClientCtpTable OBJECT-TYPE SYNTAX SEQUENCE OF SdhClientCtpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SdhClientCtp entries. Each entry is uniquely identified by the value of ifIndex." ::= { sdhClientCtpMIB 1 } sdhClientCtpEntry OBJECT-TYPE SYNTAX SdhClientCtpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A SdhClientCtp entry containing information pertaining to Infinera SdhClientCtp interfaces. Entries will exist in this table for interfaces of type sdhclientCtp." INDEX { ifIndex } ::= { sdhClientCtpTable 1 } SdhClientCtpEntry ::= SEQUENCE { sdhClientCtpTribPrbsGenMode InfnEnableDisable, sdhClientCtpTribPrbsMonMode InfnEnableDisable, sdhClientCtpSupportingCircuitIdList DisplayString, sdhClientCtpLoopback InfnLoopbackType, sdhClientCtpPmHistStatsEnable InfnPmHistStatsControl, sdhClientCtpConfiguredServiceType InfnServiceType, sdhClientCtpRxJ0 DisplayString, sdhClientCtpExpectedRxJ0 DisplayString, sdhClientCtpTransmittedJ0 DisplayString, sdhClientCtpRxJ0MessageLength Integer32, sdhClientCtpRxJ0MismatchReporting InfnEnableDisable, sdhClientCtpRxJ0TraceMode InfnJ0TraceMode, sdhClientCtpRxJ0MessageCompliance InfnJ0MessageCompliance, sdhClientCtpRxBe15MinutesTce Counter64, sdhClientCtpRxEs15MinutesTce Integer32, sdhClientCtpRxSes15MinutesTce Integer32, sdhClientCtpRxOfs15MinutesTce Integer32, sdhClientCtpRxLoss15MinutesTce Integer32, sdhClientCtpRxBeDayTce Counter64, sdhClientCtpRxEsDayTce Integer32, sdhClientCtpRxSesDayTce Integer32, sdhClientCtpRxOfsDayTce Integer32, sdhClientCtpRxLossDayTce Integer32, sdhClientCtpTxBe15MinutesTce Counter64, sdhClientCtpTxEs15MinutesTce Integer32, sdhClientCtpTxSes15MinutesTce Integer32, sdhClientCtpTxOfs15MinutesTce Integer32, sdhClientCtpTxBeDayTce Counter64, sdhClientCtpTxEsDayTce Integer32, sdhClientCtpTxSesDayTce Integer32, sdhClientCtpTxOfsDayTce Integer32, sdhClientCtpRxBe15MinutesTceReporting TruthValue, sdhClientCtpRxEs15MinutesTceReporting TruthValue, sdhClientCtpRxSes15MinutesTceReporting TruthValue, sdhClientCtpRxBeDayTceReporting TruthValue, sdhClientCtpRxEsDayTceReporting TruthValue, sdhClientCtpRxSesDayTceReporting TruthValue, sdhClientCtpRxOfs15MinutesTceReporting TruthValue, sdhClientCtpRxOfsDayReporting TruthValue, sdhClientCtpRxLoss15MinutesTceReporting TruthValue, sdhClientCtpRxLossDayReporting TruthValue, sdhClientCtpTxBe15MinutesTceReporting TruthValue, sdhClientCtpTxEs15MinutesTceReporting TruthValue, sdhClientCtpTxSes15MinutesTceReporting TruthValue, sdhClientCtpTxBeDayTceReporting TruthValue, sdhClientCtpTxEsDayTceReporting TruthValue, sdhClientCtpTxSesDayTceReporting TruthValue, sdhClientCtpTxOfs15MinutesTceReporting TruthValue, sdhClientCtpTxOfsDayReporting TruthValue, sdhClientCtpUasMonitoring InfnEnableDisable, sdhClientCtpRxUasDayTce Integer32, sdhClientCtpTxUasDayTce Integer32, sdhClientCtpTxUas15MinutesTce Integer32, sdhClientCtpRxUas15MinutesTce Integer32, sdhClientCtpRxUas15MinutesTceReporting TruthValue, sdhClientCtpTxUas15MinutesTceReporting TruthValue, sdhClientCtpRxUasDayTceReporting TruthValue, sdhClientCtpTxUasDayTceReporting TruthValue, sdhClientCtpLinePrbsGenMode InfnEnableDisable, sdhClientCtpLinePrbsMonMode InfnEnableDisable, sdhClientCtpServiceMode InfnServiceMode, sdhClientCtpServiceModeQualifier InfnSMQ, sdhClientCtpEncapClientDisableAction InfnClientAction } sdhClientCtpTribPrbsGenMode OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag which enables the generation of PRBS data on the transmit side." DEFVAL { disabled } ::= { sdhClientCtpEntry 1 } sdhClientCtpTribPrbsMonMode OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag which enables the monitoring of bit errors." DEFVAL { disabled } ::= { sdhClientCtpEntry 2 } sdhClientCtpSupportingCircuitIdList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "An unordered list of the circuitIDs supporting this Managed Object. This string contains the string representation of each supporting circuitID, separated by a ',' (comma) if there is more than one supporting circuitID." ::= { sdhClientCtpEntry 3 } sdhClientCtpLoopback OBJECT-TYPE SYNTAX InfnLoopbackType MAX-ACCESS read-write STATUS current DESCRIPTION "Flag to enable the loopback." DEFVAL { none } ::= { sdhClientCtpEntry 4 } sdhClientCtpPmHistStatsEnable OBJECT-TYPE SYNTAX InfnPmHistStatsControl MAX-ACCESS read-write STATUS current DESCRIPTION "Flag to enable or disable PM collection." DEFVAL { enabled } ::= { sdhClientCtpEntry 5 } sdhClientCtpConfiguredServiceType OBJECT-TYPE SYNTAX InfnServiceType MAX-ACCESS read-only STATUS current DESCRIPTION "The configured payload type." ::= { sdhClientCtpEntry 6 } sdhClientCtpRxJ0 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The trace that we are receiving currently. (COs update the MOs only when there is a change in the filtered received trace). CRC at the first byte is removed. Whatever is remaining is converted to ascii representation of hex string and reported to users. For example, Infinera followed by 0x1 character will result in string 'Infinera\01h'. With this approach the length could be as large as 256 characters." ::= { sdhClientCtpEntry 7 } sdhClientCtpExpectedRxJ0 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The J0 trace that is to be expected from the receive side from the customer equipment. If not zero-length and different from J0ReceivedTrace, a J0 mismatch alarm will be raised. Message is always ASCII characters." ::= { sdhClientCtpEntry 8 } sdhClientCtpTransmittedJ0 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Transmitted J0 message." ::= { sdhClientCtpEntry 9 } sdhClientCtpRxJ0MessageLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The length of J0 byte." DEFVAL { 16 } ::= { sdhClientCtpEntry 10 } sdhClientCtpRxJ0MismatchReporting OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables or disables the reporting of J0 trace mismatch condition." DEFVAL { disabled } ::= { sdhClientCtpEntry 11 } sdhClientCtpRxJ0TraceMode OBJECT-TYPE SYNTAX InfnJ0TraceMode MAX-ACCESS read-write STATUS current DESCRIPTION "The trace mode." DEFVAL { transparent } ::= { sdhClientCtpEntry 12 } sdhClientCtpRxJ0MessageCompliance OBJECT-TYPE SYNTAX InfnJ0MessageCompliance MAX-ACCESS read-write STATUS current DESCRIPTION "J0 Message trace compliance." DEFVAL { ansiItu } ::= { sdhClientCtpEntry 13 } sdhClientCtpRxBe15MinutesTce OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of errors within a block in the incoming clients SDH signal in 15 minutes." ::= { sdhClientCtpEntry 14 } sdhClientCtpRxEs15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of BIP errors detected at the Section layer in 15 minute (in the incoming clients SONET signal). Up to eight Section BIP errors can be detected per STS-N frame, with each error incrementing the Sonet-Rx-CV-S current second register." DEFVAL { 120 } ::= { sdhClientCtpEntry 15 } sdhClientCtpRxSes15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the seconds during which30% or more RS block errors were detected or an LOS or SEF defect was present in 15 minutes." DEFVAL { 3 } ::= { sdhClientCtpEntry 16 } sdhClientCtpRxOfs15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Out of Frame Seconds. Count of the number of seconds that Out of Frame is received in 15 minutes." DEFVAL { 3 } ::= { sdhClientCtpEntry 17 } sdhClientCtpRxLoss15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Loss of Signal Seconds. Count of the number of seconds that SDH client LOS is received in 15 minutes." DEFVAL { 3 } ::= { sdhClientCtpEntry 18 } sdhClientCtpRxBeDayTce OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of errors within a block in the incoming clients SDH signal in 24 hours." ::= { sdhClientCtpEntry 19 } sdhClientCtpRxEsDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of BIP errors detected at the Section layer in 24 hours (in the incoming clients SONET signal). Up to eight Section BIP errors can be detected per STS-N frame, with each error incrementing the Sonet-Rx-CV-S current second register." DEFVAL { 1200 } ::= { sdhClientCtpEntry 20 } sdhClientCtpRxSesDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the seconds during which30% or more RS block errors were detected or an LOS or SEF defect was present in 24 hours." DEFVAL { 7 } ::= { sdhClientCtpEntry 21 } sdhClientCtpRxOfsDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Out of Frame Seconds. Count of the number of seconds that Out of Frame is received in 24 hours." DEFVAL { 7 } ::= { sdhClientCtpEntry 22 } sdhClientCtpRxLossDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Loss of Signal Seconds. Count of the number of seconds that SDH client LOS is received in 24 hours." DEFVAL { 3 } ::= { sdhClientCtpEntry 23 } sdhClientCtpTxBe15MinutesTce OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of errors within a block in the SDH signal received from the network and to be transmitted to the receiving client in 15 minutes." ::= { sdhClientCtpEntry 24 } sdhClientCtpTxEs15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of seconds during which (at any point during the second) at least one Tx RS block error was detected or an LOS or SEF defect was present in 15 minutes." DEFVAL { 120 } ::= { sdhClientCtpEntry 25 } sdhClientCtpTxSes15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the seconds during which K (=10000) or more SONET TX BIP errors were detected or an LOS or SEF defect was present in 15 minutes." DEFVAL { 3 } ::= { sdhClientCtpEntry 26 } sdhClientCtpTxOfs15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Out of Frame Seconds. Count of the number of seconds that Out of Frame is detected in 15 minutes." DEFVAL { 3 } ::= { sdhClientCtpEntry 27 } sdhClientCtpTxBeDayTce OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of errors within a block in the SDH signal received from the network and to be transmitted to the receiving client in 24 hours." ::= { sdhClientCtpEntry 28 } sdhClientCtpTxEsDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the number of seconds during which (at any point during the second) at least one Tx RS block error was detected or an LOS or SEF defect was present in 24 hours." DEFVAL { 1200 } ::= { sdhClientCtpEntry 29 } sdhClientCtpTxSesDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Count of the seconds during which K (=10000) or more SONET TX BIP errors were detected or an LOS or SEF defect was present in 24 hours." DEFVAL { 7 } ::= { sdhClientCtpEntry 30 } sdhClientCtpTxOfsDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Regenerator Section - Out of Frame Seconds. Count of the number of seconds that Out of Frame is detected in 24 hours." DEFVAL { 7 } ::= { sdhClientCtpEntry 31 } sdhClientCtpRxBe15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxBe15MinutesTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 32 } sdhClientCtpRxEs15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxEs15Minutes threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 33 } sdhClientCtpRxSes15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxSes15MinutesTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 34 } sdhClientCtpRxBeDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxBeDayTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 35 } sdhClientCtpRxEsDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxEsDayTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 36 } sdhClientCtpRxSesDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxSesDayTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 37 } sdhClientCtpRxOfs15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxOfs15MinutesTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 38 } sdhClientCtpRxOfsDayReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxOfsDayTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 39 } sdhClientCtpRxLoss15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxLoss15MinutesTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 40 } sdhClientCtpRxLossDayReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of RxLossDayTce threshold crossing." DEFVAL { false } ::= { sdhClientCtpEntry 41 } sdhClientCtpTxBe15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxBe15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 42 } sdhClientCtpTxEs15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxEs15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 43 } sdhClientCtpTxSes15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxSes15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 44 } sdhClientCtpTxBeDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxBeDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 45 } sdhClientCtpTxEsDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxEsDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 46 } sdhClientCtpTxSesDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxSefsDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 47 } sdhClientCtpTxOfs15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxOfs15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 48 } sdhClientCtpTxOfsDayReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of TxOfsDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 49 } sdhClientCtpUasMonitoring OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag which enables/disables SDH Un-Available seconds PM Monitoring" DEFVAL { disabled } ::= { sdhClientCtpEntry 50 } sdhClientCtpRxUas15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "15 minutest receive count for Unavailable seconds" DEFVAL { 1 } ::= { sdhClientCtpEntry 51 } sdhClientCtpRxUasDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "24 hour receive count for un available seconds." DEFVAL { 1 } ::= { sdhClientCtpEntry 52 } sdhClientCtpTxUas15MinutesTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "15 minutes transmit count for unavailable seconds." DEFVAL { 1 } ::= { sdhClientCtpEntry 53 } sdhClientCtpTxUasDayTce OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "24 hours transmit count for unavilable seconds." DEFVAL { 1 } ::= { sdhClientCtpEntry 54 } sdhClientCtpRxUas15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of SdhRxUas15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 55 } sdhClientCtpRxUasDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of SdhRxUasDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 56 } sdhClientCtpTxUas15MinutesTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of sdhTxUas15MinutesTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 57 } sdhClientCtpTxUasDayTceReporting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag that enables the reporting of SdhTxUasDayTce crossing." DEFVAL { false } ::= { sdhClientCtpEntry 58 } sdhClientCtpLinePrbsGenMode OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag which enables the generation of PRBS data on the Line side." DEFVAL { disabled } ::= { sdhClientCtpEntry 59 } sdhClientCtpLinePrbsMonMode OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "Flag which enables the monitoring of bit errors." DEFVAL { disabled } ::= { sdhClientCtpEntry 60 } sdhClientCtpServiceMode OBJECT-TYPE SYNTAX InfnServiceMode MAX-ACCESS read-only STATUS current DESCRIPTION "The Service Mode (SM) of the client CTP (i.e., the mode/type of service in which this SDH client CTP is being used." ::= { sdhClientCtpEntry 61 } sdhClientCtpServiceModeQualifier OBJECT-TYPE SYNTAX InfnSMQ MAX-ACCESS read-only STATUS current DESCRIPTION "The Service Mode Qualifier (SMQ) of the SDH client CTP (i.e., the mode/type of service in which this SDH client CTP is being used." ::= { sdhClientCtpEntry 62 } sdhClientCtpEncapClientDisableAction OBJECT-TYPE SYNTAX InfnClientAction MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { sdhClientCtpEntry 63 } -- Conformance Statements sdhClientCtpConformance OBJECT IDENTIFIER ::= { sdhClientCtpMIB 3 } sdhClientCtpCompliances OBJECT IDENTIFIER ::= { sdhClientCtpConformance 1 } sdhClientCtpGroups OBJECT IDENTIFIER ::= { sdhClientCtpConformance 2 } sdhClientCtpCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the SDHCLIENTCTP-MIB" MODULE MANDATORY-GROUPS { sdhClientCtpGroup } ::= { sdhClientCtpCompliances 1 } sdhClientCtpGroup OBJECT-GROUP OBJECTS { sdhClientCtpTribPrbsGenMode, sdhClientCtpTribPrbsMonMode, sdhClientCtpSupportingCircuitIdList, sdhClientCtpLoopback, sdhClientCtpPmHistStatsEnable, sdhClientCtpConfiguredServiceType, sdhClientCtpRxJ0, sdhClientCtpExpectedRxJ0, sdhClientCtpTransmittedJ0, sdhClientCtpRxJ0MessageLength, sdhClientCtpRxJ0MismatchReporting, sdhClientCtpRxJ0TraceMode, sdhClientCtpRxJ0MessageCompliance, sdhClientCtpRxBe15MinutesTce, sdhClientCtpRxEs15MinutesTce, sdhClientCtpRxSes15MinutesTce, sdhClientCtpRxOfs15MinutesTce, sdhClientCtpRxLoss15MinutesTce, sdhClientCtpRxBeDayTce, sdhClientCtpRxEsDayTce, sdhClientCtpRxSesDayTce, sdhClientCtpRxOfsDayTce, sdhClientCtpRxLossDayTce, sdhClientCtpTxBe15MinutesTce, sdhClientCtpTxEs15MinutesTce, sdhClientCtpTxSes15MinutesTce, sdhClientCtpTxOfs15MinutesTce, sdhClientCtpTxBeDayTce, sdhClientCtpTxEsDayTce, sdhClientCtpTxSesDayTce, sdhClientCtpTxOfsDayTce, sdhClientCtpRxBe15MinutesTceReporting, sdhClientCtpRxEs15MinutesTceReporting, sdhClientCtpRxSes15MinutesTceReporting, sdhClientCtpRxBeDayTceReporting, sdhClientCtpRxEsDayTceReporting, sdhClientCtpRxSesDayTceReporting, sdhClientCtpRxOfs15MinutesTceReporting, sdhClientCtpRxOfsDayReporting, sdhClientCtpRxLoss15MinutesTceReporting, sdhClientCtpRxLossDayReporting, sdhClientCtpTxBe15MinutesTceReporting, sdhClientCtpTxEs15MinutesTceReporting, sdhClientCtpTxSes15MinutesTceReporting, sdhClientCtpTxBeDayTceReporting, sdhClientCtpTxEsDayTceReporting, sdhClientCtpTxSesDayTceReporting, sdhClientCtpTxOfs15MinutesTceReporting, sdhClientCtpTxOfsDayReporting, sdhClientCtpUasMonitoring, sdhClientCtpRxUasDayTce, sdhClientCtpTxUasDayTce, sdhClientCtpTxUas15MinutesTce, sdhClientCtpRxUas15MinutesTce, sdhClientCtpRxUas15MinutesTceReporting, sdhClientCtpTxUas15MinutesTceReporting, sdhClientCtpRxUasDayTceReporting, sdhClientCtpTxUasDayTceReporting, sdhClientCtpServiceMode, sdhClientCtpServiceModeQualifier , sdhClientCtpEncapClientDisableAction } STATUS current DESCRIPTION " A collection of objects for managing the sdhClientCtp" ::= { sdhClientCtpGroups 1 } END