-- ***************************************************************** -- INFINERA-PM-SECYRXSCSTATS-MIB -- -- October 2016, Kavitha Manjunatha -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-PM-SECYRXSCSTATS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue FROM SNMPv2-TC ifIndex FROM IF-MIB HCPerfIntervalCount FROM HC-PerfHist-TC-MIB macsecPerfMon FROM INFINERA-REG-MIB; secyRxSCStatsPmMIB MODULE-IDENTITY LAST-UPDATED "201502060000Z" ORGANIZATION "Infinera" CONTACT-INFO "Infinera 1322 Bordeaux Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION " " REVISION "201502060000Z" DESCRIPTION "First Version" ::= { macsecPerfMon 2 } -- Real PMs -- secyRxSCStatsPmRealTable OBJECT-TYPE -- SYNTAX SEQUENCE OF SecyRxSCStatsRealEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A list of SecyRxSCStatsReal entries. Each entry is uniquely identified by the value of ifIndex." -- ::= { secyRxSCStatsPmMIB 1 } -- -- secyRxSCStatsPmRealEntry OBJECT-TYPE -- SYNTAX SecyRxSCStatsRealEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "A secyRxSCStatsPm entry containing real-time performance information pertaining to -- Infinera Fan interfaces. . This table is a subclass of IfCommon. -- Entries will exist in this table only for interfaces of secyRxSCStats." -- INDEX { ifIndex } -- ::= { secyRxSCStatsPmRealTable 1 } -- SecyRxSCStatsRealEntry ::= SEQUENCE { -- secyRxSCStatsPmRealInRpmRaw FloatTenths -- } -- Historical PMs secyRxSCStatsPmTable OBJECT-TYPE SYNTAX SEQUENCE OF SecyRxSCStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SecyRxSCStats entries. Each entry is uniquely identified by the value of ifIndex, sampleDuration and secyRxSCStatsPmTimestamp." ::= { secyRxSCStatsPmMIB 2 } secyRxSCStatsPmEntry OBJECT-TYPE SYNTAX SecyRxSCStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Fan entry containing historical performance information pertaining to Infinera Fan interfaces. . This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of type Fan. Each interface may have a number of entries in this table, each with a different combination of timestamp and sample duration." INDEX { ifIndex, secyRxSCStatsPmSampleDuration, secyRxSCStatsPmTimestamp } ::= { secyRxSCStatsPmTable 1 } SecyRxSCStatsEntry ::= SEQUENCE { secyRxSCStatsPmTimestamp Integer32, secyRxSCStatsPmSampleDuration INTEGER, secyRxSCStatsPmValidity TruthValue, secyRxSCStatsPmUnusedSAPkts HCPerfIntervalCount, secyRxSCStatsPmNotUsingSAPkts HCPerfIntervalCount, secyRxSCStatsPmLatePkts HCPerfIntervalCount, secyRxSCStatsPmNotValidPkts HCPerfIntervalCount, secyRxSCStatsPmInvalidPkts HCPerfIntervalCount, secyRxSCStatsPmDelayedPkts HCPerfIntervalCount, secyRxSCStatsPmUncheckedPkts HCPerfIntervalCount, secyRxSCStatsPmOKPkts HCPerfIntervalCount, secyRxSCStatsPmOctetsValidated HCPerfIntervalCount, secyRxSCStatsPmOctetsDecrypted HCPerfIntervalCount } secyRxSCStatsPmTimestamp OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "End Time stamp for this interval. If this time is later than the current time, then the data for this bucket is currently being collected." ::= { secyRxSCStatsPmEntry 1 } secyRxSCStatsPmSampleDuration OBJECT-TYPE SYNTAX INTEGER { fifteenMinutes(1), day(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The duration of this sample." ::= { secyRxSCStatsPmEntry 2 } secyRxSCStatsPmValidity OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Flag indicating if data was valid for the entire interval" ::= { secyRxSCStatsPmEntry 3 } secyRxSCStatsPmUnusedSAPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats UnusedSAPkts" ::= { secyRxSCStatsPmEntry 4 } secyRxSCStatsPmNotUsingSAPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats NotUsingSAPkts" ::= { secyRxSCStatsPmEntry 5 } secyRxSCStatsPmLatePkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats LatePkts" ::= { secyRxSCStatsPmEntry 6 } secyRxSCStatsPmNotValidPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats NotValidPkts" ::= { secyRxSCStatsPmEntry 7 } secyRxSCStatsPmInvalidPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats InvalidPkts" ::= { secyRxSCStatsPmEntry 8 } secyRxSCStatsPmDelayedPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats DelayedPkts" ::= { secyRxSCStatsPmEntry 9 } secyRxSCStatsPmUncheckedPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats UncheckedPkts" ::= { secyRxSCStatsPmEntry 10 } secyRxSCStatsPmOKPkts OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats OKPkts" ::= { secyRxSCStatsPmEntry 11 } secyRxSCStatsPmOctetsValidated OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats OctetsValidated" ::= { secyRxSCStatsPmEntry 12 } secyRxSCStatsPmOctetsDecrypted OBJECT-TYPE SYNTAX HCPerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION "SECY RXSCStats OctetsDecrypted" ::= { secyRxSCStatsPmEntry 13 } -- Conformance Statements secyRxSCStatsPmConformance OBJECT IDENTIFIER ::= { secyRxSCStatsPmMIB 3 } secyRxSCStatsPmCompliances OBJECT IDENTIFIER ::= { secyRxSCStatsPmConformance 1 } secyRxSCStatsPmGroups OBJECT IDENTIFIER ::= { secyRxSCStatsPmConformance 2 } secyRxSCStatsPmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the PM-SECYRXSCSTATS-MIB" -- MODULE -- MANDATORY-GROUPS { secyRxSCStatsPmRealGroup } ::= { secyRxSCStatsPmCompliances 1 } -- secyRxSCStatsPmRealCompliance MODULE-COMPLIANCE -- STATUS current -- DESCRIPTION -- "Describes the requirements for conformance to the secyRxSCStatsPmReal-MIB" -- MODULE -- MANDATORY-GROUPS { secyRxSCStatsPmRealGroup } -- ::= { secyRxSCStatsPmCompliances 2 } -- Historical PM groups secyRxSCStatsPmGroup OBJECT-GROUP OBJECTS { secyRxSCStatsPmValidity, secyRxSCStatsPmUnusedSAPkts, secyRxSCStatsPmNotUsingSAPkts, secyRxSCStatsPmLatePkts, secyRxSCStatsPmNotValidPkts, secyRxSCStatsPmInvalidPkts, secyRxSCStatsPmDelayedPkts, secyRxSCStatsPmUncheckedPkts, secyRxSCStatsPmOKPkts, secyRxSCStatsPmOctetsValidated, secyRxSCStatsPmOctetsDecrypted } STATUS current DESCRIPTION " A collection of objects for reading SecyRxSCStats." ::= { secyRxSCStatsPmGroups 1 } END