-- ***************************************************************** -- INFINERA-PM-OSAPTP-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-PM-OSAPTP-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue FROM SNMPv2-TC ifIndex FROM IF-MIB FloatHundredths FROM INFINERA-TC-MIB perfMon FROM INFINERA-REG-MIB; osaPtpPmMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "Infinera" CONTACT-INFO "Infinera 1322 Bordeaux Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION " " REVISION "200810200000Z" DESCRIPTION "First Version" ::= { perfMon 19 } osaPtpPmTable OBJECT-TYPE SYNTAX SEQUENCE OF OsaPtpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of OsaPtpPm entries. Each entry is uniquely identified by the value of ifIndex and osaPtpPmTimestamp." ::= { osaPtpPmMIB 2 } osaPtpPmEntry OBJECT-TYPE SYNTAX OsaPtpPmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A OsaPtp entry containing historical performance information pertaining to Infinera BMM OCG PTP interfaces. This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of type BMM OCG PTP. Each interface may have a number of entries in this table, each with a different combination of timestamp and sample duration." INDEX { ifIndex, osaPtpPmSampleDuration, osaPtpPmTimestamp } ::= { osaPtpPmTable 1 } OsaPtpPmEntry ::= SEQUENCE { osaPtpPmTimestamp Integer32, osaPtpPmSampleDuration INTEGER, osaPtpPmValidity TruthValue, osaPtpPmOprMin FloatHundredths, osaPtpPmOprMax FloatHundredths, osaPtpPmOprAve FloatHundredths } osaPtpPmTimestamp OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "End Time stamp for this interval. If this time is later than the current time, then the data for this bucket is currently being collected." ::= { osaPtpPmEntry 1 } osaPtpPmSampleDuration OBJECT-TYPE SYNTAX INTEGER { fifteenMinutes(1), day(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The duration of this sample." ::= { osaPtpPmEntry 2 } osaPtpPmValidity OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Flag indicating if data was valid for the entire interval" ::= { osaPtpPmEntry 3 } osaPtpPmOprMin OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum optical power received." ::= { osaPtpPmEntry 4 } osaPtpPmOprMax OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum optical power received." ::= { osaPtpPmEntry 5 } osaPtpPmOprAve OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "Average optical power received." ::= { osaPtpPmEntry 6 } osaPtpPmRealTable OBJECT-TYPE SYNTAX SEQUENCE OF OsaPtpPmRealEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of OsaPtpPmReal entries. Each entry is uniquely identified by the value of ifIndex." ::= { osaPtpPmMIB 1 } osaPtpPmRealEntry OBJECT-TYPE SYNTAX OsaPtpPmRealEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A OsaPtp entry containing real-time performance information pertaining to Infinera BMM OCG PTP interfaces. This table is a subclass of IfCommon. Entries will exist in this table only for interfaces of type BMM OCG PTP." INDEX { ifIndex } ::= { osaPtpPmRealTable 1 } OsaPtpPmRealEntry ::= SEQUENCE { osaPtpPmRealOpr FloatHundredths, osaOprOsaTapRatio FloatHundredths } osaPtpPmRealOpr OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "Osa Opr" ::= { osaPtpPmRealEntry 1 } osaOprOsaTapRatio OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "Opr Osa ratio" ::= { osaPtpPmRealEntry 2 } -- Conformance Statements osaPtpPmConformance OBJECT IDENTIFIER ::= { osaPtpPmMIB 3 } osaPtpPmCompliances OBJECT IDENTIFIER ::= { osaPtpPmConformance 1 } osaPtpPmGroups OBJECT IDENTIFIER ::= { osaPtpPmConformance 2 } osaPtpPmCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the OSAPTP-MIB" MODULE MANDATORY-GROUPS { osaPtpPmGroup } ::= { osaPtpPmCompliances 1 } osaPtpPmRealCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "Describes the requirements for conformance to the osaPtpPmReal-MIB" MODULE MANDATORY-GROUPS { osaPtpPmRealGroup } ::= { osaPtpPmCompliances 2 } osaPtpPmGroup OBJECT-GROUP OBJECTS { osaPtpPmValidity, osaPtpPmOprMin, osaPtpPmOprMax, osaPtpPmOprAve } STATUS current DESCRIPTION " A collection of objects for reading the historical performance of the osaPtp." ::= { osaPtpPmGroups 1 } osaPtpPmRealGroup OBJECT-GROUP OBJECTS { osaPtpPmRealOpr, osaOprOsaTapRatio } STATUS current DESCRIPTION " A collection of objects for reading the real-time performance of the osaPtp." ::= { osaPtpPmGroups 2 } END