-- *************************************************************** -- INFINERA-ENTITY-TAM-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-ENTITY-TAM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF RowStatus, DisplayString FROM SNMPv2-TC entLPPhysicalIndex FROM ENTITY-MIB equipment FROM INFINERA-REG-MIB InfnEqptType FROM INFINERA-TC-MIB; tamMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "INFINERA" CONTACT-INFO "Infinera 169 Java Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION "This MIB is modeling for TAM equipment table." ::= { equipment 7 } tamConformance OBJECT IDENTIFIER ::= { tamMIB 3 } tamCompliances OBJECT IDENTIFIER ::= { tamConformance 1 } tamGroups OBJECT IDENTIFIER ::= { tamConformance 2 } tamTable OBJECT-TYPE SYNTAX SEQUENCE OF TamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all TAM modules that are currently present in a network element. " ::= { tamMIB 1 } tamEntry OBJECT-TYPE SYNTAX TamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the TAM table. Each row in the table is identified with a unique entPhysicalIndexID. " INDEX { entLPPhysicalIndex } ::= { tamTable 1 } TamEntry ::= SEQUENCE { tamMoId DisplayString, tamProvEqptType InfnEqptType, tamRowStatus RowStatus } tamMoId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This is the primary Key of the objects e.g 1-A-3-1" ::= { tamEntry 1 } tamProvEqptType OBJECT-TYPE SYNTAX InfnEqptType MAX-ACCESS read-create STATUS current DESCRIPTION "The configured TAM type." ::= { tamEntry 2 } tamRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of this TAM entry. Because rows in this table are indexed by entPhysicalIndex, to create a new row one must choose a value of entPhysicalIndex that is not already in use. A side-effect of the creation of a row in this table is the creation of a corresponding row in the eqptTable and the entPhysicalTable. The status may not be set to active if the tamMoId and tamProvEqptType are not set to valid values. This row may only be deleted if it was a pre-provisioned row and the hardware is not present. If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be deleted by the agent." ::= { tamEntry 3 } tamCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "" MODULE MANDATORY-GROUPS { tamGroup } ::= { tamCompliances 1 } tamGroup OBJECT-GROUP OBJECTS { tamMoId, tamProvEqptType, tamRowStatus } STATUS current DESCRIPTION "" ::= { tamGroups 1 } END