-- *************************************************************** -- INFINERA-ENTITY-CHASSIS-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-ENTITY-CHASSIS-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF RowStatus, DisplayString, TruthValue FROM SNMPv2-TC entLPPhysicalIndex FROM ENTITY-MIB equipment FROM INFINERA-REG-MIB FloatThousandths, FloatHundredths, FloatArbitraryPrecision, FloatTenths, InfnChassisType, InfnPmHistStatsControl, InfnChassisSwitchingMode, InfnEnableDisable FROM INFINERA-TC-MIB; chassisMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "INFINERA" CONTACT-INFO "Infinera 169 Java Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION "This MIB is modeling for CHASSIS equipment table." ::= { equipment 13 } chassisConformance OBJECT IDENTIFIER ::= { chassisMIB 3 } chassisCompliances OBJECT IDENTIFIER ::= { chassisConformance 1 } chassisGroups OBJECT IDENTIFIER ::= { chassisConformance 2 } chassisTable OBJECT-TYPE SYNTAX SEQUENCE OF ChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all chassis modules that are currently present in a network element." ::= { chassisMIB 1 } chassisEntry OBJECT-TYPE SYNTAX ChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the CHASSIS table. Each row in the table is identified with a unique entPhysicalIndexID. " INDEX { entLPPhysicalIndex } ::= { chassisTable 1 } ChassisEntry ::= SEQUENCE { chassisMoId DisplayString, chassisProvChassisType InfnChassisType, chassisInstalledChassisType InfnChassisType, chassisProvSerialNumber DisplayString, chassisInstalledSerialNumber DisplayString, chassisRackName DisplayString, chassisRUlocationInRack Unsigned32, chassisSwitchCapabilityMode INTEGER, chassisInletTemperature FloatArbitraryPrecision, chassisAcoState INTEGER, chassisBayLevelSummaryAlarmReporting INTEGER, chassisConfiguredMaxPowerDraw FloatThousandths, chassisCurrentEstimatedPowerDraw FloatThousandths, chassisEqptMaxPowerDraw FloatHundredths, chassisScmMigrationAllowed TruthValue, chassisScmMigrationInProgress TruthValue, chassisPowerControl INTEGER, chassiscurrentInstalledPowerDraw FloatThousandths, chassisConfiguredPemRating Unsigned32, chassisRowStatus RowStatus, chassisIsNCChassis TruthValue, chassisSwitchingMode InfnChassisSwitchingMode, chassisMaxAvailablePower FloatThousandths, chassisActvTimingSource DisplayString, chassisConfiguredAmbientTemp Unsigned32, chassisSkewBudget INTEGER, chassisOperatingTemperatureThreshold Integer32, chassisPduCktBreakerRating FloatArbitraryPrecision, chassisRebootTime Integer32, chassisCLEI DisplayString, chassisHardwareVersion DisplayString, chassisManufacturedDate DisplayString, chassisPartNumber DisplayString, chassisPON DisplayString, chassisHolderType INTEGER, chassisHolderState INTEGER, chassisAcceptableEquipmentTypeList DisplayString, chassisUnreachableFromManagement TruthValue, chassisSerialPortCLIAccess InfnEnableDisable, chassisAcliSessionAdminState InfnEnableDisable, chassisFruInsertionDate DisplayString, chassisPowerSupplyType INTEGER, chassisBaffleType INTEGER, chassisPmHistStatsEnable InfnPmHistStatsControl, chassisInletTemperatureOffset FloatTenths, chassisHasPluggableEeprom TruthValue, chassisPluggablePromSerialNumber DisplayString, chassisOutletTemperature FloatArbitraryPrecision, chassisTTLMax Integer32, chassisTTLCurrentDays Integer32 } chassisMoId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This is the primary Key of the objects e.g 1, 2, 3..." ::= { chassisEntry 1 } chassisProvChassisType OBJECT-TYPE SYNTAX InfnChassisType MAX-ACCESS read-create STATUS current DESCRIPTION "The provisioned chassis. Valid values: OTC, DTC, DTC-A, DTC-B, and MTC-A." ::= { chassisEntry 2 } chassisInstalledChassisType OBJECT-TYPE SYNTAX InfnChassisType MAX-ACCESS read-only STATUS current DESCRIPTION "The installed chassis type." ::= { chassisEntry 3 } chassisProvSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The provisioned serial number of the Expansion Chassis. This field is configured for the expansion chassis in a multi-chassis configuration. This attribute can be modified only when the Admin State of the chassis (Expansion Chassis only) is Locked." ::= { chassisEntry 4 } chassisInstalledSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The actual serial number of the chassis" ::= { chassisEntry 5 } chassisRackName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the rack in which the chassis is installed." ::= { chassisEntry 6 } chassisRUlocationInRack OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The position of the chassis within the rack. The chassis with lower RU location is displayed at the bottom in the node view and the one with higher number is displayed at the top. If there are more than two chassis having the same rack name, they are displayed next to each other though they might be physically located in the same rack." ::= { chassisEntry 7 } chassisSwitchCapabilityMode OBJECT-TYPE SYNTAX INTEGER { ring (1), mesh (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The switch capability mode for the chassis. Valid values: ring and mesh." ::= { chassisEntry 8 } chassisInletTemperature OBJECT-TYPE SYNTAX FloatArbitraryPrecision MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature (in Centigrade) of the circuit pack at the inlet. The temperature is displayed as -1 if the circuit pack does not have a temperature sensor." ::= { chassisEntry 9 } chassisAcoState OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The chassis alarm cutoff state." ::= { chassisEntry 10 } chassisBayLevelSummaryAlarmReporting OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Flag that enables reporting of bay-level alarms. Typically, this is enabled for one chassis within a bay and disabled for all other chassis in the same bay. Vaid values:enabled and disabled." ::= { chassisEntry 11 } chassisConfiguredMaxPowerDraw OBJECT-TYPE SYNTAX FloatThousandths MAX-ACCESS read-create STATUS current DESCRIPTION "The estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration." ::= { chassisEntry 12 } chassisCurrentEstimatedPowerDraw OBJECT-TYPE SYNTAX FloatThousandths MAX-ACCESS read-only STATUS current DESCRIPTION "The sum of estimated power drawn by all the currently installed and pre-provisioned FRUs in the chassis. This value is not indicative of the actual power drawn." ::= { chassisEntry 13 } chassisEqptMaxPowerDraw OBJECT-TYPE SYNTAX FloatHundredths MAX-ACCESS read-only STATUS current DESCRIPTION "The estimated power drawn by the chassis. This varies depending on the type of the chassis and associated configuration." ::= { chassisEntry 14 } chassisScmMigrationAllowed OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicate whether user can chnage the chassisSwitchCapabilityMode. If this is false user will not be able to chnage." ::= { chassisEntry 15 } chassisScmMigrationInProgress OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "This objects indicate that switch capability mode change is in progress." ::= { chassisEntry 16 } chassisPowerControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This objects enable the auto power saving if pwoer is hitting the limit." ::= { chassisEntry 17 } chassiscurrentInstalledPowerDraw OBJECT-TYPE SYNTAX FloatThousandths MAX-ACCESS read-only STATUS current DESCRIPTION "The estimated power drawn by the installed equipment in chassis. This varies depending on the type of the chassis and installed equipment." ::= { chassisEntry 18 } chassisConfiguredPemRating OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute tells what is the compatible PEM rating for the chassis , in case of PEM-35 this attribute should be set to 35 and in case of PEM-70 it should be set to 70. Accordingly RatingAmps attribute of PEM will change and in case RatingAmps value of PEM doesn't matche with its InstalledRatingAmps then equipment mismatch alarm will be raised." ::= { chassisEntry 19 } chassisRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of this CHASSIS entry. Because rows in this table are indexed by entPhysicalIndex, to create a new row one must choose a value of entPhysicalIndex that is not already in use. A side-effect of the creation of a row in this table is the creation of a corresponding row in the eqptTable and the entPhysicalTable. The status may not be set to active if the chassisMoId, chassisProvEqptType and other read-create objects are not set to valid values. This row may only be deleted if it was a pre-provisioned row and the hardware is not present. If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be deleted by the agent." ::= { chassisEntry 20 } chassisIsNCChassis OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "whether or not this chassis houses the Node Controller XCM." ::= { chassisEntry 21 } chassisSwitchingMode OBJECT-TYPE SYNTAX InfnChassisSwitchingMode MAX-ACCESS read-only STATUS current DESCRIPTION "current configuration of the chassis switch fabric module." ::= { chassisEntry 22 } chassisMaxAvailablePower OBJECT-TYPE SYNTAX FloatThousandths MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum available power in the chassis" ::= { chassisEntry 23 } chassisActvTimingSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 24 } chassisOperatingTemperatureThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 25 } chassisConfiguredAmbientTemp OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 26 } chassisSkewBudget OBJECT-TYPE SYNTAX INTEGER { none (1), low (2), high (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { chassisEntry 27 } chassisPduCktBreakerRating OBJECT-TYPE SYNTAX FloatArbitraryPrecision MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 28 } chassisRebootTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 29 } chassisCLEI OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 30 } chassisHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 31 } chassisManufacturedDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 32 } chassisPartNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 33 } chassisPON OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 34 } chassisHolderType OBJECT-TYPE SYNTAX INTEGER { chassis(1), self(2), slot(3), subSlot(4), unknown (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 35 } chassisHolderState OBJECT-TYPE SYNTAX INTEGER { empty (1), plugIn(2), installed(3), installedAndExpected(4), mismatchOfInstalledAndExpected(5), unknown(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 36 } chassisAcceptableEquipmentTypeList OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 37 } chassisUnreachableFromManagement OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 38 } chassisSerialPortCLIAccess OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 39} chassisAcliSessionAdminState OBJECT-TYPE SYNTAX InfnEnableDisable MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 40 } chassisFruInsertionDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 41 } chassisPowerSupplyType OBJECT-TYPE SYNTAX INTEGER { native(1), unmanaged3rdparty(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 42 } chassisBaffleType OBJECT-TYPE SYNTAX INTEGER { none(1), mtc9AirBaffle(2), mtc9AirBaffle2(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { chassisEntry 43 } chassisPmHistStatsEnable OBJECT-TYPE SYNTAX InfnPmHistStatsControl MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 44 } chassisInletTemperatureOffset OBJECT-TYPE SYNTAX FloatTenths MAX-ACCESS read-write STATUS current DESCRIPTION "Inlet Temperature Offset" ::= { chassisEntry 45 } chassisHasPluggableEeprom OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Flag to indicate if the device has pluggable Eeprom" ::= { chassisEntry 46 } chassisPluggablePromSerialNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Plugged in Eeprom serial number" ::= { chassisEntry 47 } chassisOutletTemperature OBJECT-TYPE SYNTAX FloatArbitraryPrecision MAX-ACCESS read-only STATUS current DESCRIPTION "The outlet temperature of the chassis" ::= { chassisEntry 48 } chassisTTLMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 49 } chassisTTLCurrentDays OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { chassisEntry 50 } chassisCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "" MODULE MANDATORY-GROUPS { chassisGroup } ::= { chassisCompliances 1 } chassisGroup OBJECT-GROUP OBJECTS { chassisMoId, chassisProvChassisType, chassisInstalledChassisType, chassisProvSerialNumber, chassisInstalledSerialNumber, chassisRackName, chassisRUlocationInRack, chassisSwitchCapabilityMode, chassisInletTemperature, chassisAcoState, chassisBayLevelSummaryAlarmReporting, chassisConfiguredMaxPowerDraw, chassisCurrentEstimatedPowerDraw, chassisEqptMaxPowerDraw, chassisScmMigrationAllowed, chassisScmMigrationInProgress, chassisPowerControl, chassiscurrentInstalledPowerDraw, chassisConfiguredPemRating, chassisRowStatus, chassisIsNCChassis, chassisSwitchingMode, chassisMaxAvailablePower, chassisActvTimingSource, chassisOperatingTemperatureThreshold, chassisConfiguredAmbientTemp, chassisSkewBudget, chassisPduCktBreakerRating, chassisRebootTime , chassisCLEI , chassisHardwareVersion , chassisManufacturedDate , chassisPartNumber , chassisPON , chassisHolderType , chassisHolderState , chassisAcceptableEquipmentTypeList, chassisUnreachableFromManagement , chassisSerialPortCLIAccess , chassisAcliSessionAdminState , chassisFruInsertionDate , chassisPowerSupplyType , chassisBaffleType , chassisPmHistStatsEnable, chassisInletTemperatureOffset, chassisHasPluggableEeprom, chassisPluggablePromSerialNumber, chassisOutletTemperature, chassisTTLMax, chassisTTLCurrentDays } STATUS current DESCRIPTION "" ::= { chassisGroups 1 } END