-- ================================================================= -- Copyright (c) 2004-2014 by H3C Technologies. All rights reserved. -- -- Description: -- Reference: -- Version: V1.7 -- History: -- V1.0 created by liujingya. -- Initial version of the MIB -- V1.1 2008-1-29 Adjusted the structure of some tables and the value of -- some objects by liujingya. -- V1.2 2008-5-19 Added h3cEOCComUniAdminStatus, h3cEOCComCnuSoftwareVersion, -- modified description of h3cEOCComUniUpLineRate and -- h3cEOCComUniDownLineRate by liujingya. -- V1.3 2008-7-30 updated by xujun -- add h3cEOCComCnuRateDropThr, h3cEOCComCnuTxRate, h3cEOCComCnuRxRate, -- h3cEOCComCnuTxRateDrop, h3cEOCComCnuRxRateDrop, h3cEOCCnuTxRateDropTrap, -- h3cEOCCnuTxRateDropRecoverTrap, h3cEOCCnuRxRateDropTrap and -- h3cEOCCnuRxRateDropRecoverTrap by xujun -- V1.4 2009-2-13 Added h3cEOCCnuFWDownLoadErrTrap, -- h3cEOCCnuFWDownLoadErrReTrap, h3cEOCCnuDeviceTypeErrTrap, -- h3cEOCCnuDeviceTypeErrReTrap, h3cEOCCnuAutoUpdateErrTrap, -- h3cEOCCnuAutoUpdateSuccTrap and -- modified MAX-ACCESS of h3cEOCComCnuDeviceType by liujingya. -- V1.5 2010-1-7 Added h3cEocComCnuTypeIdx, h3cEOCComCnuDescripton, -- h3cEOCComCltMaxAllowToAccess, h3cEocComCnuNumber by xujun -- V1.6 2011-12-28 updated by gaoguangping -- Added h3cEOCLoopbackDetectTrap, h3cEOCLoopbackRecoverTrap; -- Modified h3cEOCComCnuLinkState. -- V1.7 2013-08-20 Added h3cEOCComCnuTempIndex by xujun -- ================================================================= H3C-EOC-COMMON-MIB DEFINITIONS ::= BEGIN IMPORTS h3cCommon FROM HUAWEI-3COM-OID-MIB ifIndex, ifDescr FROM IF-MIB Integer32, Unsigned32, TimeTicks, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Gauge32 FROM SNMPv2-SMI IANAifType FROM IANAifType-MIB MacAddress, RowStatus, DisplayString, TruthValue FROM SNMPv2-TC h3cHPEOCDownLoadCNUFWResult FROM H3C-HPEOC-MIB; h3cEOCCommon MODULE-IDENTITY LAST-UPDATED "200709111008Z" ORGANIZATION "Hangzhou H3C Tech. Co., Ltd." CONTACT-INFO "SMB EOC Team H3C Technologies Co., Ltd. 310 Liuhe Road, Zhijiang Science Park, Hangzhou, P.R.China http://www.h3c.com Zip:310053." DESCRIPTION " The objects in this MIB module are used to manage and display common configuration between Ethernet Passive Optical Network (EOC) port which are based on the Ethernet in the First Mile (EFM) Passive Optical Network(PON) as defined in IEEE Draft P802.3ah/D3.0 clause 60, 64, 65.. and Ethernet Over Cable (EOC) which is based on HomePlug AV Specification. " ::= { h3cCommon 83 } -- -- h3cEOCCommonSysMan -- h3cEOCCommonSysMan OBJECT IDENTIFIER ::= { h3cEOCCommon 1 } h3cEOCCommonSysScalarObjects OBJECT IDENTIFIER ::= { h3cEOCCommonSysMan 1 } h3cEOCCommonSysVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION " Eoc version. If the object length is zero, it means the version is unknown. The length is up to 1024. " ::= { h3cEOCCommonSysScalarObjects 1 } h3cEOCCommonUpLinkMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION " EOC CLT's uplink device's mac address. " ::= { h3cEOCCommonSysScalarObjects 2 } -- -- h3cEOCCommonCltMan -- h3cEOCCommonCltMan OBJECT IDENTIFIER ::= { h3cEOCCommon 2 } -- -- h3cEOCCommonCltManTable -- h3cEOCCommonCltManTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCCommonCltManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table defines the primary parameters of the CLT configuration. " ::= { h3cEOCCommonCltMan 1 } h3cEOCCommonCltManEntry OBJECT-TYPE SYNTAX H3cEOCCommonCltManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the table h3cEOCCommonCltManTable. " INDEX { ifIndex } ::= { h3cEOCCommonCltManTable 1 } H3cEOCCommonCltManEntry ::= SEQUENCE { h3cEOCCommonCltAutoAuthorize TruthValue, h3cEOCCommonCltMaxAllowToAccess Integer32 } h3cEOCCommonCltAutoAuthorize OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION " This value determines whether software performs self-authorization for each Cable Network Unit(CNU) registering to the network. Setting it to false means for every CNU registering, software requires external authorization, and until it's done the CNU is not authenticated. True value means software authorizes each CNU registering to the network automatically. " DEFVAL { false } ::= { h3cEOCCommonCltManEntry 1 } h3cEOCCommonCltMaxAllowToAccess OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " This value determines how many CNU can be bound in this CLT. If the number of CNU is more than this value , then the rest of CNU should not be allow to access. " DEFVAL { 253 } ::= { h3cEOCCommonCltManEntry 2 } -- -- h3cEOCComCnuMan -- h3cEOCComCnuMan OBJECT IDENTIFIER ::= { h3cEOCCommon 3 } h3cEOCComCnuScalarObjects OBJECT IDENTIFIER ::= { h3cEOCComCnuMan 1 } h3cEOCComCnuMaxDownBWMinVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The lower limit of total-bandwidth which is confined to h3cEOCComCnuMaxDownBW." ::= { h3cEOCComCnuScalarObjects 1 } h3cEOCComCnuMaxDownBWMaxVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The upper limit of total-bandwidth which is confined to h3cEOCComCnuMaxDownBW." ::= { h3cEOCComCnuScalarObjects 2 } h3cEOCComCnuSlaHighPriBWMinVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The lower limit of high priority bandwidth which is confined to h3cEOCComCnuSlaHighPriBW." ::= { h3cEOCComCnuScalarObjects 3 } h3cEOCComCnuSlaHighPriBWMaxVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The upper limit of high priority bandwidth which is confined to h3cEOCComCnuSlaHighPriBW." ::= { h3cEOCComCnuScalarObjects 4 } h3cEOCComCnuMaxUpBWMinVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The lower limit of total-bandwidth which is confined to h3cEOCComCnuMaxUpBW." ::= { h3cEOCComCnuScalarObjects 5 } h3cEOCComCnuMaxUpBWMaxVal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The upper limit of total-bandwidth which is confined to h3cEOCComCnuMaxUpBW." ::= { h3cEOCComCnuScalarObjects 6 } h3cEOCComCnuAttenThrA OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The value of cnu's average attenuation good level thresholds. " ::= { h3cEOCComCnuScalarObjects 7 } h3cEOCComCnuAttenThrB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The value of cnu's average attenuation normal level thresholds. " ::= { h3cEOCComCnuScalarObjects 8 } h3cEOCComCnuRateDropThr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The value of cnu's Tx/Rx rate drop thresholds. " ::= { h3cEOCComCnuScalarObjects 9 } -- -- h3cEOCComCnuSysManTable -- h3cEOCComCnuSysManTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuSysManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table implements the management of CNUs(Coax Network Unit). " ::= { h3cEOCComCnuMan 2 } h3cEOCComCnuSysManEntry OBJECT-TYPE SYNTAX H3cEOCComCnuSysManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the table h3cEOCComCnuSysManTable. " INDEX { ifIndex } ::= { h3cEOCComCnuSysManTable 1 } H3cEOCComCnuSysManEntry ::= SEQUENCE { h3cEOCComCnuCableIfindex Integer32, h3cEOCComCnuDeviceType DisplayString, h3cEOCComCnuDeviceAlias DisplayString, h3cEOCComCnuDescr DisplayString, h3cEOCComCnuUpTime TimeTicks, h3cEOCComCnuVLANType INTEGER, h3cEOCComCnuPvid Integer32, h3cEOCComCnuVlanTag INTEGER, h3cEOCComCnuReset INTEGER, h3cEOCComCnuDeregister INTEGER, h3cEOCComCnuSave INTEGER, h3cEOCComCnuAccess INTEGER } h3cEOCComCnuCableIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The index of cable port which uniquely identifies the cable port of one device. " ::= { h3cEOCComCnuSysManEntry 1 } h3cEOCComCnuDeviceType OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " The type of the EOC CNU(Coax Network Unit). " ::= { h3cEOCComCnuSysManEntry 2 } h3cEOCComCnuDeviceAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " EOC CNU's alias which display as the device's name, it's recommended to set it uniquely and understandably. " ::= { h3cEOCComCnuSysManEntry 3 } h3cEOCComCnuDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " User's description, including user's address, name, telephone number and so on. " ::= { h3cEOCComCnuSysManEntry 4 } h3cEOCComCnuUpTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION " The time since the CNU last registered to the network. " ::= { h3cEOCComCnuSysManEntry 5 } h3cEOCComCnuVLANType OBJECT-TYPE SYNTAX INTEGER { vLANTrunk(1), access(2), hybrid(3), fabric(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "port vlan types. hybrid (3) port can carry multiple VLANs. If fabric function is supported, fabric(4) means the port is a fabric port." ::= { h3cEOCComCnuSysManEntry 6 } h3cEOCComCnuPvid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION " The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on cable interface. " REFERENCE " IEEE 802.1Q/D11 Section 12.10.1.1 " DEFVAL { 1 } ::= { h3cEOCComCnuSysManEntry 7 } h3cEOCComCnuVlanTag OBJECT-TYPE SYNTAX INTEGER { tagged(1), untagged(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " VLAN is set tagged or untagged on cable interface. " ::= { h3cEOCComCnuSysManEntry 8 } h3cEOCComCnuReset OBJECT-TYPE SYNTAX INTEGER { running(1), reset(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " This variable is used to reset the CNU device. The interface may be unavailable while the reset occurs and data may be lost. During reading operation it returns the state of the CNU device. running(1) indicates and operates normal operation, reset(2) indicates and operates reset mode. Writing can be done all the time. " ::= { h3cEOCComCnuSysManEntry 9 } h3cEOCComCnuDeregister OBJECT-TYPE SYNTAX INTEGER { deregister(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " deregister CNU. " ::= { h3cEOCComCnuSysManEntry 10 } h3cEOCComCnuSave OBJECT-TYPE SYNTAX INTEGER { save(1), running(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Save the UNI and CNU related configurations to the CNU. " ::= { h3cEOCComCnuSysManEntry 11 } h3cEOCComCnuAccess OBJECT-TYPE SYNTAX INTEGER { access(1), notaccess(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Control whether the user can access to the network. " ::= { h3cEOCComCnuSysManEntry 12 } -- -- h3cEOCComCnuMacTable -- h3cEOCComCnuMacTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table implements the management of CNUs. " ::= { h3cEOCComCnuMan 3 } h3cEOCComCnuMacEntry OBJECT-TYPE SYNTAX H3cEOCComCnuMacEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the table h3cEOCComCnuMacTable. " INDEX { ifIndex } ::= { h3cEOCComCnuMacTable 1 } H3cEOCComCnuMacEntry ::= SEQUENCE { h3cEOCComCnuMacAddress MacAddress, h3cEOCComCnuRowStatus RowStatus, h3cEOCComCnuTempIndex Integer32 } h3cEOCComCnuMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-create STATUS current DESCRIPTION " EOC CNU's MAC address. " ::= { h3cEOCComCnuMacEntry 1 } h3cEOCComCnuRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " Operation status. " ::= { h3cEOCComCnuMacEntry 2 } h3cEOCComCnuTempIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " EOC CNU's model index from h3cHPEOCTemplateIndex, If configure 0, the CNU select no model. " ::= { h3cEOCComCnuMacEntry 3 } -- -- h3cEOCComCnuInfoTable -- h3cEOCComCnuInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Primary status of the specified CNU. There will be one row in this table for each information in the system. " ::= { h3cEOCComCnuMan 4 } h3cEOCComCnuInfoEntry OBJECT-TYPE SYNTAX H3cEOCComCnuInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the h3cEOCComCnuInfoTable. " INDEX { ifIndex } ::= { h3cEOCComCnuInfoTable 1 } H3cEOCComCnuInfoEntry ::= SEQUENCE { h3cEOCComCnuHardwareVersion DisplayString, h3cEOCComCnuPCBVersion OCTET STRING, h3cEOCComCnuLinkState INTEGER, h3cEOCComCnuAttenuation Integer32, h3cEOCComCnuSoftwareVersion DisplayString, h3cEOCComCnuTxRate Integer32, h3cEOCComCnuRxRate Integer32, h3cEOCComCnuTxRateDrop Integer32, h3cEOCComCnuRxRateDrop Integer32 } h3cEOCComCnuHardwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " EOC CNU's hardware version. If the object length is zero, it means the version is unknown. " ::= { h3cEOCComCnuInfoEntry 1 } h3cEOCComCnuPCBVersion OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION " EOC CNU's PCB version. " ::= { h3cEOCComCnuInfoEntry 2 } h3cEOCComCnuLinkState OBJECT-TYPE SYNTAX INTEGER { physicaldown(1), linkdown(2), linkup(3), loopback(4) } MAX-ACCESS read-only STATUS current DESCRIPTION " The cable port's link state. The physicaldown(1) state indicates that the CNU is not powered on. The linkdown(2) state indicates that the CNU is powered on, but registers fail. The linkup(3) state indicates that the CNU is powered on, and registers successful. The loopback(4) state indecates that the CNU is powered on and registers successful, but loopback has detected. " ::= { h3cEOCComCnuInfoEntry 3 } h3cEOCComCnuAttenuation OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The cnu's average attenuation. " ::= { h3cEOCComCnuInfoEntry 4 } h3cEOCComCnuSoftwareVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " EOC CNU's software version. If the object length is zero, it means the version is unknown. " ::= { h3cEOCComCnuInfoEntry 5 } h3cEOCComCnuTxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The cnu's capability of tx speed in unit of 1Mbps. " ::= { h3cEOCComCnuInfoEntry 6 } h3cEOCComCnuRxRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The cnu's capability of rx speed in unit of 1Mbps. " ::= { h3cEOCComCnuInfoEntry 7 } h3cEOCComCnuTxRateDrop OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The cnu's capability droping of tx speed from it's history max value in unit of %. " ::= { h3cEOCComCnuInfoEntry 8 } h3cEOCComCnuRxRateDrop OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The cnu's capability droping of rx speed from it's history max value in unit of %. " ::= { h3cEOCComCnuInfoEntry 9 } -- -- h3cEOCComCnuBandWidthTable -- h3cEOCComCnuBandWidthTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuBandWidthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Set bandwidth parameters. " ::= { h3cEOCComCnuMan 5 } h3cEOCComCnuBandWidthEntry OBJECT-TYPE SYNTAX H3cEOCComCnuBandWidthEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of table h3cEOCComCnuBandWidthTable. It is a pre-configuration. " INDEX { ifIndex } ::= { h3cEOCComCnuBandWidthTable 1 } H3cEOCComCnuBandWidthEntry ::= SEQUENCE { h3cEOCComCnuMaxDownBW Integer32, h3cEOCComCnuSlaHighPriBW Integer32, h3cEOCComCnuMaxUpBW Integer32 } h3cEOCComCnuMaxDownBW OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Maximum bandwidth allowed for the CNU, measured in Kbit/s. " ::= { h3cEOCComCnuBandWidthEntry 1 } h3cEOCComCnuSlaHighPriBW OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " High priority bandwidth - measured in Kbit/s. The value of this object should be the multiple of the value of h3cEOCComCnuMaxUpBW. The high priority bandwidth should not be larger than the maximum bandwidth. " ::= { h3cEOCComCnuBandWidthEntry 2 } h3cEOCComCnuMaxUpBW OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Total bandwidth - measured in Kbit/s. The value of this object should be the multiple of the value of h3cEOCComCnuSlaHighPriBW. The total bandwidth should be larger than the high priority bandwidth. " ::= { h3cEOCComCnuBandWidthEntry 3 } -- -- h3cEOCComUniMan -- h3cEOCComUniMan OBJECT IDENTIFIER ::= { h3cEOCCommon 4 } h3cEOCComUniManTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComUniManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table defines several user network interface(UNI) system parameters. " ::= { h3cEOCComUniMan 1 } h3cEOCComUniManEntry OBJECT-TYPE SYNTAX H3cEOCComUniManEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of h3cEOCComUniManTable. " INDEX { ifIndex, h3cEOCUniIndex } ::= { h3cEOCComUniManTable 1 } H3cEOCComUniManEntry ::= SEQUENCE { h3cEOCUniIndex Unsigned32, h3cEOCComUniDescr DisplayString, h3cEOCComUniStatus INTEGER, h3cEOCComUniSpeed INTEGER, h3cEOCComUniDuplex INTEGER, h3cEOCComUniCurrentSpeed Gauge32, h3cEOCComUniCurrentDuplex INTEGER, h3cEOCComUniMdi INTEGER, h3cEOCComUniFlowControl TruthValue, h3cEOCComUniCountReset INTEGER, h3cEOCComUniAlias DisplayString, h3cEOCComUniType IANAifType, h3cEOCComUniVLANType INTEGER, h3cEOCComUniPvid Integer32, h3cEOCComUniVlanTag INTEGER, h3cEOCComUniPriority Integer32, h3cEOCComUniUpLineRate Unsigned32, h3cEOCComUniDownLineRate Unsigned32, h3cEOCComUniAdminStatus INTEGER } h3cEOCUniIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION " The index value which uniquely identifies the FE(Fast Ethernet) interface of the CNU. " ::= { h3cEOCComUniManEntry 1 } h3cEOCComUniDescr OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " A textual string containing information about the interface. This string should include the name of the manufacturer, the product name and the version of the interface hardware and software. " ::= { h3cEOCComUniManEntry 2 } h3cEOCComUniStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " The desired state of the user network interface. When a managed system initializes, all user network interfaces start with down state. The testing state indicates that no operational packets can be passed. As a result of either explicit management action or per configuration information retained by the managed system, h3cEOCComUniStatus is then changed to either the up or testing states (or remains in the down state). " ::= { h3cEOCComUniManEntry 3 } h3cEOCComUniSpeed OBJECT-TYPE SYNTAX INTEGER { auto(1), s10M(10), s100M(100) } MAX-ACCESS read-write STATUS current DESCRIPTION " User network interface speed. " ::= { h3cEOCComUniManEntry 4 } h3cEOCComUniDuplex OBJECT-TYPE SYNTAX INTEGER { full(1), half(2), auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " User network interface mode. " ::= { h3cEOCComUniManEntry 5 } h3cEOCComUniCurrentSpeed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " An estimate of the interface's current bandwidth in bits per second. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. If the bandwidth of the interface is greater than the maximum value reportable by this object then this object should report its maximum value (4,294,967,295). For a sub-layer which has no concept of bandwidth, this object should be zero. " ::= { h3cEOCComUniManEntry 6 } h3cEOCComUniCurrentDuplex OBJECT-TYPE SYNTAX INTEGER { full(1), half(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION " The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. " REFERENCE " [IEEE 802.3 Std.], 30.3.1.1.32, aDuplexStatus. " ::= { h3cEOCComUniManEntry 7 } h3cEOCComUniMdi OBJECT-TYPE SYNTAX INTEGER { mdi-ii(1), mdi-x(2), mdi-auto(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Type of the line connected to UNI interface: mdi-ii(straight-through cable), mdi-x (crossover cable), mdi-auto (auto-sensing)." DEFVAL { mdi-auto } ::= { h3cEOCComUniManEntry 8 } h3cEOCComUniFlowControl OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flow control status. true(1) - Flow control status enable. false(2) - Flow control status disable." DEFVAL { false } ::= { h3cEOCComUniManEntry 9 } h3cEOCComUniCountReset OBJECT-TYPE SYNTAX INTEGER { reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Reset the counter which is about packets of the interface, then the counter will change to zero. There is no sense in reading this object." ::= { h3cEOCComUniManEntry 10 } h3cEOCComUniAlias OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION " This object is an 'alias' name for the interface as specified by a network manager, and provides a non- volatile 'handle' for the interface. On the first instantiation of an interface, the value of h3cEOCComUniAlias associated with that interface is the zero-length string. As and when a value is written into an instance of h3cEOCComUniAlias through a network management set operation, then the agent must retain the supplied value in the h3cEOCComUniAlias instance associated with the same interface for as long as that interface remains instantiated, including across all re- initializations/reboots of the network management system, including those which result in a change of the interface's ifIndex and h3cEOCUniIndex value. An example of the value which a network manager might store in this object for a WAN interface is the (Telco's) circuit number/identifier of the interface. Some agents may support write-access only for interfaces having particular values of h3cEOCComUniType. An agent which supports write access to this object is required to keep the value in non-volatile storage, but it may limit the length of new values depending on how much storage is already occupied by the current values for other interfaces. " ::= { h3cEOCComUniManEntry 11 } h3cEOCComUniType OBJECT-TYPE SYNTAX IANAifType MAX-ACCESS read-only STATUS current DESCRIPTION " The type of interface. Additional values for h3cEOCComUniType are assigned by the Internet Assigned Numbers Authority(IANA), through updating the syntax of the IANAifType textual convention. " ::= { h3cEOCComUniManEntry 12 } h3cEOCComUniVLANType OBJECT-TYPE SYNTAX INTEGER { vLANTrunk(1), access(2), hybrid(3), fabric(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "port vlan types. hybrid (3) port can carry multiple VLANs. If fabric function is supported, fabric(4) means the port is a fabric port." ::= { h3cEOCComUniManEntry 13 } h3cEOCComUniPvid OBJECT-TYPE SYNTAX Integer32 (1..4094) MAX-ACCESS read-write STATUS current DESCRIPTION " The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames received on this port. " REFERENCE " IEEE 802.1Q/D11 Section 12.10.1.1 " DEFVAL { 1 } ::= { h3cEOCComUniManEntry 14 } h3cEOCComUniVlanTag OBJECT-TYPE SYNTAX INTEGER { tagged(1), untagged(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " VLAN is set tagged or untagged. " ::= { h3cEOCComUniManEntry 15 } h3cEOCComUniPriority OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION " The default ingress User Priority for this port. This only has effect on media, such as Ethernet, that do not support native User Priority. " ::= { h3cEOCComUniManEntry 16 } h3cEOCComUniUpLineRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max speed upload in units of 1,000 bits per second on this interface. The value should between 0 and 100Mbps. If the value is 0, it means that the upload speed is only restricted by the physical line. " ::= { h3cEOCComUniManEntry 17 } h3cEOCComUniDownLineRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION " The max speed download in units of 1,000 bits per second on this interface. The value should between 0 and 100Mbps. If the value is 0, it means that the download speed is only restricted by the physical line. " ::= { h3cEOCComUniManEntry 18 } h3cEOCComUniAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Control if open or close the UNI. If choose up(1), means the UNI is opened and packets can pass it. If choose down(2), means the UNI is closed and all packets will be discard. " ::= { h3cEOCComUniManEntry 19 } -- -- h3cEOCComUniCountTable -- h3cEOCComUniCountTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComUniCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of interface counter about frames entries." ::= { h3cEOCComUniMan 2 } h3cEOCComUniCountEntry OBJECT-TYPE SYNTAX H3cEOCComUniCountEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular interface." INDEX { ifIndex, h3cEOCUniIndex } ::= { h3cEOCComUniCountTable 1 } H3cEOCComUniCountEntry ::= SEQUENCE { h3cEOCUniInPkts Unsigned32, h3cEOCUniInUPkts Unsigned32, h3cEOCUniInBPkts Unsigned32, h3cEOCUniInMPkts Unsigned32, h3cEOCUniInPausePkts Unsigned32, h3cEOCUniInTotalErrors Unsigned32, h3cEOCUniInCRCErrs Unsigned32, h3cEOCUniInUndersizePkts Unsigned32, h3cEOCUniInOversizePkts Unsigned32, h3cEOCUniInErrorbyOther Unsigned32, h3cEOCUniInOctets Unsigned32, h3cEOCUniOutPkts Unsigned32, h3cEOCUniOutUPkts Unsigned32, h3cEOCUniOutBPkts Unsigned32, h3cEOCUniOutMPkts Unsigned32, h3cEOCUniOutPausePkts Unsigned32, h3cEOCUniOutTotalErrors Unsigned32, h3cEOCUniOutCollisions Unsigned32, h3cEOCUniOutDelayExceedDsds Unsigned32, h3cEOCUniOutErrorbyOther Unsigned32, h3cEOCUniOutDroppedFrames Unsigned32, h3cEOCUniOutOctets Unsigned32 } h3cEOCUniInPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets, broadcast packets, and multicast packets) received." ::= { h3cEOCComUniCountEntry 1 } h3cEOCUniInUPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets received that are directed to the unicast address. Note that this does not include multicast and broadcast packets." ::= { h3cEOCComUniCountEntry 2 } h3cEOCUniInBPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets received that are directed to the broadcast address. Note that this does not include multicast packets." ::= { h3cEOCComUniCountEntry 3 } h3cEOCUniInMPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets received that are directed to a multicast address. Note that this number does not include packets directed to the broadcast address." ::= { h3cEOCComUniCountEntry 4 } h3cEOCUniInPausePkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of MAC Control packets received on this interface by the pause(flow control) operation. This counter does not increment when the interface is in a half-duplex mode. Discontinuities in the value of this counter can occur at re-initialization of the management system." ::= { h3cEOCComUniCountEntry 5 } h3cEOCUniInTotalErrors OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total count of the error packets received on this interface." ::= { h3cEOCComUniCountEntry 6 } h3cEOCUniInCRCErrs OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error)." ::= { h3cEOCComUniCountEntry 7 } h3cEOCUniInUndersizePkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that are less than 64 octets long (excluding framing bits, but including FCS octets) and are otherwise well formed." ::= { h3cEOCComUniCountEntry 8 } h3cEOCUniInOversizePkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets received that are longer than 1518 octets (excluding framing bits, but including FCS octets) and are otherwise well formed." ::= { h3cEOCComUniCountEntry 9 } h3cEOCUniInErrorbyOther OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of other error packets received on this interface." ::= { h3cEOCComUniCountEntry 10 } h3cEOCUniInOctets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets received on this interface." ::= { h3cEOCComUniCountEntry 11 } h3cEOCUniOutPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of packets (including bad packets, broadcast packets, and multicast packets) sent." ::= { h3cEOCComUniCountEntry 12 } h3cEOCUniOutUPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets sent that are directed to the unicast address. Note that this does not include multicast and broadcast packets." ::= { h3cEOCComUniCountEntry 13 } h3cEOCUniOutBPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets sent that are directed to the broadcast address. Note that this does not include multicast packets." ::= { h3cEOCComUniCountEntry 14 } h3cEOCUniOutMPkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of good packets sent that are directed to a multicast address. Note that this number does not include packets directed to the broadcast address." ::= { h3cEOCComUniCountEntry 15 } h3cEOCUniOutPausePkts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of MAC control packets sent on this interface by the pause operation. This counter does not increment when the interface is in a half-duplex mode. Discontinuities in the value of this counter can occur at re-initialization of the management system." ::= { h3cEOCComUniCountEntry 16 } h3cEOCUniOutTotalErrors OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of error packets sent on this interface." ::= { h3cEOCComUniCountEntry 17 } h3cEOCUniOutCollisions OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The best estimate of the total number of collisions on this Ethernet segment. The value returned will depend on the location of the RMON probe. Section 8.2.1.3 (10BASE-5) and section 10.3.1.3 (10BASE-2) of IEEE standard 802.3 states that a station must detect a collision, in the receive mode, if three or more stations are transmitting simultaneously. A repeater port must detect a collision when two or more stations are transmitting simultaneously. Thus a probe placed on a repeater port could record more collisions than a probe connected to a station on the same segment could. Probe location plays a much smaller role when considering 10BASE-T. 14.2.1.4 (10BASE-T) of IEEE standard 802.3 defines a collision as the simultaneous presence of signals on the DO and RD circuits (transmitting and receiving at the same time). A 10BASE-T station can only detect collisions when it is transmitting. Thus probes placed on a station and a repeater, should report the same number of collisions. Note also that an RMON probe inside a repeater should ideally report collisions between the repeater and one or more other hosts (transmit collisions as defined by IEEE 802.3k) plus receiver collisions observed on any coax segments to which the repeater is connected." ::= { h3cEOCComUniCountEntry 18 } h3cEOCUniOutDelayExceedDsds OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of packets discarded by this port due to excessive transit delay through the bridge. It is incremented by both transparent and source route bridges." ::= { h3cEOCComUniCountEntry 19 } h3cEOCUniOutErrorbyOther OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of other error packets sent on this interface. Other error packets means the error packets out of collision packets and excessive delayed packets." ::= { h3cEOCComUniCountEntry 20 } h3cEOCUniOutDroppedFrames OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames dropped because of buffer failure." ::= { h3cEOCComUniCountEntry 21 } h3cEOCUniOutOctets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of octets transmitted out of the interface." ::= { h3cEOCComUniCountEntry 22 } -- -- h3cEOCCommon NOTIFICATION -- h3cEOCCommonTrap OBJECT IDENTIFIER ::= { h3cEOCCommon 5 } h3cEOCTrapPrefix OBJECT IDENTIFIER ::= {h3cEOCCommonTrap 0} h3cEOCCnuRegExcessTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuRegExcessTrap notification is sent when the number of registered CNUs exceeds the limit. " ::= { h3cEOCTrapPrefix 1 } h3cEOCCnuRegExcessRecoverTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuRegExcessRecoverTrap notification is sent when h3cEOCCnuRegExcessTrap is detected and then recoverd. " ::= { h3cEOCTrapPrefix 2 } h3cEOCCnuRegSuccTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuRegSuccTrap notification is sent when a CNU registers successful. " ::= { h3cEOCTrapPrefix 3 } h3cEOCCnuOffLineTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuOffLineTrap notification is sent when a CNU offline. " ::= { h3cEOCTrapPrefix 4 } h3cEOCCnuLinkupTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuLinkupTrap notification is sent when a CNU linkup. " ::= { h3cEOCTrapPrefix 5 } h3cEOCOamDisconnectTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCOamDisconnectionTrap notification is sent when LLID's OAM link is disconnected. " ::= { h3cEOCTrapPrefix 6 } h3cEOCOamDisconnectRecoverTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCOamDisconnectionRecoverTrap notification is sent when LLID's OAM link is disconnected and then connected. " ::= { h3cEOCTrapPrefix 7 } h3cEOCBandwidthNotEnoughTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " Bandwidth is not enough, cnu can not bind now. " ::= { h3cEOCTrapPrefix 8 } h3cEOCCnuAttenuationTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuAttenuation } STATUS current DESCRIPTION " A h3cHPEOCCnuAttenuationTrap notification is sent when a CNU's attenuation is changing. " ::= { h3cEOCTrapPrefix 9 } h3cEOCCnuRegFailTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCnuRegFailTrap notification is sent when a CNU registers fail. " ::= { h3cEOCTrapPrefix 10 } h3cEOCCLTCablePortErrorTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCLTCablePortErrorTrap notification is sent when the hardware of cable port occurs error or CLT's vlan is configged error. " ::= { h3cEOCTrapPrefix 11 } h3cEOCCLTCablePortErrReTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr } STATUS current DESCRIPTION " A h3cEOCCLTCablePortErrReTrap notification is sent when cable port error and then recovered. " ::= { h3cEOCTrapPrefix 12 } h3cEOCCnuTxRateDropTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuTxRateDrop } STATUS current DESCRIPTION " A h3cEOCCnuTxRateDropTrap notification is sent when cable port rate of TX capability drop exceeded threshold. " ::= { h3cEOCTrapPrefix 13 } h3cEOCCnuTxRateDropRecoverTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuTxRateDrop } STATUS current DESCRIPTION " A h3cEOCCnuTxRateDropRecoverTrap notification is sent when cable port rate of TX capability recover from the recent rate-drop trap. " ::= { h3cEOCTrapPrefix 14 } h3cEOCCnuRxRateDropTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuRxRateDrop } STATUS current DESCRIPTION " A h3cEOCCnuRxRateDropTrap notification is sent when cable port rate of RX capability drop exceeded threshold. " ::= { h3cEOCTrapPrefix 15 } h3cEOCCnuRxRateDropRecoverTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuRxRateDrop } STATUS current DESCRIPTION " A h3cEOCCnuRxRateDropRecoverTrap notification is sent when cable port rate of RX capability recover from the recent rate-drop trap. " ::= { h3cEOCTrapPrefix 16 } h3cEOCCnuFWDownLoadErrTrap NOTIFICATION-TYPE OBJECTS { h3cHPEOCDownLoadCNUFWResult } STATUS current DESCRIPTION " A h3cEOCCnuFWDownLoadErrTrap notification is sent when CLT can't download CNU firmware from the server successfully. " ::= { h3cEOCTrapPrefix 17 } h3cEOCCnuFWDownLoadErrReTrap NOTIFICATION-TYPE STATUS current DESCRIPTION " A h3cEOCCnuFWDownLoadErrReTrap notification is sent when CLT recover from the download CNU firmware error. " ::= { h3cEOCTrapPrefix 18 } h3cEOCCnuDeviceTypeErrTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress, h3cEOCComCnuDeviceType } STATUS current DESCRIPTION " A h3cEOCCnuDeviceTypeErrTrap notification is sent when the online CNU doesn't match the type which user defined earlier. " ::= { h3cEOCTrapPrefix 19 } h3cEOCCnuDeviceTypeErrReTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress } STATUS current DESCRIPTION " A h3cEOCCnuDeviceTypeErrReTrap notification is sent when the online CNU doesn't match the type which user defined earlier and then recover. " ::= { h3cEOCTrapPrefix 20 } h3cEOCCnuAutoUpdateErrTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress } STATUS current DESCRIPTION " A h3cEOCCnuAutoUpdateErrTrap notification is sent when the online CNU doesn't auto update successfully. " ::= { h3cEOCTrapPrefix 21 } h3cEOCCnuAutoUpdateSuccTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress } STATUS current DESCRIPTION " A h3cEOCCnuAutoUpdateSuccTrap notification is sent when the online CNU auto update successfully. " ::= { h3cEOCTrapPrefix 22 } h3cEOCLoopbackDetectTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress } STATUS current DESCRIPTION " A h3cEOCLoopbackDetectTrap notification is sent when the loopback between the ethernet ports of CNU or CLT is found. " ::= { h3cEOCTrapPrefix 23 } h3cEOCLoopbackRecoverTrap NOTIFICATION-TYPE OBJECTS { ifIndex, ifDescr, h3cEOCComCnuMacAddress } STATUS current DESCRIPTION " A h3cEOCLoopbackRecoverTrap notification is sent when the loopback between the ethernet ports of CNU or CLT is recover. " ::= { h3cEOCTrapPrefix 24 } -- -- h3cEOCComOnLineCnuMan -- h3cEOCComOnLineCnuMan OBJECT IDENTIFIER ::= { h3cEOCCommon 6 } -- -- h3cEOCComCnuTypeTable -- h3cEOCComCnuTypeTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table defines the description of cnu typ. " ::= { h3cEOCComOnLineCnuMan 1 } h3cEOCComCnuTypeEntry OBJECT-TYPE SYNTAX H3cEOCComCnuTypeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the table h3cEOCComCnuTypeTable. " INDEX { h3cEOCComCnuTypeIdx } ::= { h3cEOCComCnuTypeTable 1 } H3cEOCComCnuTypeEntry ::= SEQUENCE { h3cEOCComCnuTypeIdx Unsigned32, h3cEOCComCnuDescripton DisplayString } h3cEOCComCnuTypeIdx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION " A unique value for each cnu types. Its value ranges between 1 and the value of cny typess. " ::= { h3cEOCComCnuTypeEntry 1 } h3cEOCComCnuDescripton OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION " The description for unique cnu types. " ::= { h3cEOCComCnuTypeEntry 2 } -- -- h3cEOCComCnuNumTable -- h3cEOCComCnuNumTable OBJECT-TYPE SYNTAX SEQUENCE OF H3cEOCComCnuNumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table defines the number of cnu registered in variable types of the CLT . " ::= { h3cEOCComOnLineCnuMan 2 } h3cEOCComCnuNumEntry OBJECT-TYPE SYNTAX H3cEOCComCnuNumEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " The entry of the table h3cEOCComCnuNumTable. " INDEX { ifIndex, h3cEOCComCnuTypeIdx } ::= { h3cEOCComCnuNumTable 1 } H3cEOCComCnuNumEntry ::= SEQUENCE { h3cEOCComCnuNumber Integer32 } h3cEOCComCnuNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The number of special type of cnu that has been registerd in clt. " ::= { h3cEOCComCnuNumEntry 1 } END