GUDEADS-EPC2X6-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Counter32, Integer32, IpAddress FROM SNMPv2-SMI OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; gudeads MODULE-IDENTITY LAST-UPDATED "200703051356Z" -- Mar 5, 2007 1:56:00 PM ORGANIZATION "Gude Analog- und Digitalsysteme GmbH" CONTACT-INFO "http://www.gudeads.com/" DESCRIPTION "" REVISION "200703051356Z" -- Mar 5, 2007 1:56:00 PM DESCRIPTION "$Id: GUDEADS-EPC2X6-MIB.txt,v 1.5 2009-04-03 14:03:39 petes1 Exp $" -- 1.3.6.1.4.1.28507 ::= { enterprises 28507 } epc2x6portFuses OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Bit State of Fuses (Bit 0 = Fuse1, Bit 1 = Fuse2)" -- 1.3.6.1.4.1.28507.6.1.2.3 ::= { epc2x6powerports 3 } epc2x6Temperature OBJECT-TYPE SYNTAX Integer32 UNITS "10th of degree Celsius" MAX-ACCESS read-only STATUS current DESCRIPTION "actual Temperature, if sensor is not supported '9998', not connected '9999' is given back as result" -- 1.3.6.1.4.1.28507.6.1.3 ::= { epc2x6Objects 3 } epc2x6witchEvt1 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.1 ::= { events 1 } epc2x6witchEvt2 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.2 ::= { events 2 } epc2x6witchEvt3 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.3 ::= { events 3 } epc2x6witchEvt4 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.4 ::= { events 4 } epc2x6witchEvt5 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.5 ::= { events 5 } epc2x6witchEvt6 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.6 ::= { events 6 } epc2x6witchEvt7 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.7 ::= { events 7 } epc2x6witchEvt8 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.8 ::= { events 8 } epc2x6witchEvt9 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.9 ::= { events 9 } epc2x6witchEvt10 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.10 ::= { events 10 } epc2x6witchEvt11 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.11 ::= { events 11 } epc2x6witchEvt12 NOTIFICATION-TYPE OBJECTS { epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount} STATUS current DESCRIPTION "Event is triggered when" -- 1.3.6.1.4.1.28507.0.12 ::= { events 12 } -- Notification Types -- events OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.0 ::= { gudeads 0 } epc2x6SNMPaccess OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.1.1 ::= { epc2x6Objects 1 } epc2x6TrapCtrl OBJECT-TYPE SYNTAX Integer32 (0..2) MAX-ACCESS read-write STATUS current DESCRIPTION "0 = off 1 = Ver. 1 2 = Ver. 2c" -- 1.3.6.1.4.1.28507.6.1.1.1 ::= { epc2x6SNMPaccess 1 } epc2x6TrapIPTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc2x6TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all Trap receiver" -- 1.3.6.1.4.1.28507.6.1.1.2 ::= { epc2x6SNMPaccess 2 } gadsEPC2x6 OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6 ::= { gudeads 6 } -- Scalars and Tables -- epc2x6Objects OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.1 ::= { gadsEPC2x6 1 } epc2x6TrapIPEntry OBJECT-TYPE SYNTAX Epc2x6TrapIPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "an entry containing management informations regarding the list of trap receivers" INDEX { epc2x6TrapIPIndex } -- 1.3.6.1.4.1.28507.6.1.1.2.1 ::= { epc2x6TrapIPTable 1 } Epc2x6TrapIPEntry ::= SEQUENCE { epc2x6TrapIPIndex Integer32, epc2x6TrapIPAddr IpAddress, epc2x6TrapIPPort Integer32 } epc2x6TrapIPIndex OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each receiver slot." -- 1.3.6.1.4.1.28507.6.1.1.2.1.1 ::= { epc2x6TrapIPEntry 1 } epc2x6TrapIPPort OBJECT-TYPE SYNTAX Integer32 (0..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "IP Port specifying one Trap receiver slot. A value of 0 disables this slot." DEFVAL { 162 } -- 1.3.6.1.4.1.28507.6.1.1.2.1.3 ::= { epc2x6TrapIPEntry 3 } epc2x6powerports OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.1.2 ::= { epc2x6Objects 2 } epc2x6portNumber OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PowerPorts" -- 1.3.6.1.4.1.28507.6.1.2.1 ::= { epc2x6powerports 1 } -- the Interfaces table -- The Interfaces table contains information on the entity's -- interfaces. Each sub-layer below the internetwork-layer -- of a network interface is considered to be an interface. epc2x6portTable OBJECT-TYPE SYNTAX SEQUENCE OF Epc2x6portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "list of all EPC Powerports" -- 1.3.6.1.4.1.28507.6.1.2.2 ::= { epc2x6powerports 2 } epc2x6portEntry OBJECT-TYPE SYNTAX Epc2x6portEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular powerport." INDEX { epc2x6PortIndex } -- 1.3.6.1.4.1.28507.6.1.2.2.1 ::= { epc2x6portTable 1 } Epc2x6portEntry ::= SEQUENCE { epc2x6PortIndex Integer32, epc2x6PortName OCTET STRING, epc2x6PortState INTEGER, epc2x6PortSwitchCount Counter32, epc2x6PortStartupMode INTEGER, epc2x6PortStartupDelay Integer32, epc2x6PortRepowerTime Integer32 } epc2x6PortIndex OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each PowerPort." -- 1.3.6.1.4.1.28507.6.1.2.2.1.1 ::= { epc2x6portEntry 1 } epc2x6PortName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..15)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing name of a PowerPort." -- 1.3.6.1.4.1.28507.6.1.2.2.1.2 ::= { epc2x6portEntry 2 } epc2x6PortState OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "current state a PowerPort" -- 1.3.6.1.4.1.28507.6.1.2.2.1.3 ::= { epc2x6portEntry 3 } epc2x6PortSwitchCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of switch actions ocurred on a PowerPort. Does not count switch commands which will not switch the ralay state, so just real relay switches are displayed here." -- 1.3.6.1.4.1.28507.6.1.2.2.1.4 ::= { epc2x6portEntry 4 } -- Conformance -- epc2x6Conf OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.3 ::= { gadsEPC2x6 3 } -- Groups -- epc2x6Groups OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.3.1 ::= { epc2x6Conf 1 } -- Compliance -- epc2x6Compls OBJECT IDENTIFIER -- 1.3.6.1.4.1.28507.6.3.2 ::= { epc2x6Conf 2 } epc2x6BasicGroup OBJECT-GROUP OBJECTS { epc2x6portNumber, epc2x6PortName, epc2x6PortState, epc2x6PortSwitchCount, epc2x6TrapCtrl, epc2x6TrapIPAddr, epc2x6TrapIPPort, epc2x6Temperature, epc2x6portFuses, epc2x6PortStartupMode, epc2x6PortStartupDelay, epc2x6PortRepowerTime } STATUS current DESCRIPTION "Basic objects." -- 1.3.6.1.4.1.28507.6.3.1.1 ::= { epc2x6Groups 1 } epc2x6TrapIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP Address specifying one Trap receiver slot. A value of '00000000'H disables this slot." DEFVAL { '00000000'H } -- 1.3.6.1.4.1.28507.6.1.1.2.1.2 ::= { epc2x6TrapIPEntry 2 } epc2x6NotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { epc2x6witchEvt1, epc2x6witchEvt2, epc2x6witchEvt3, epc2x6witchEvt4, epc2x6witchEvt5, epc2x6witchEvt6, epc2x6witchEvt7, epc2x6witchEvt8, epc2x6witchEvt9, epc2x6witchEvt10, epc2x6witchEvt11, epc2x6witchEvt12, epc2x6TempEvt, epc2x6FuseEvt } STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.6.3.1.2 ::= { epc2x6Groups 2 } epc2x6PortStartupMode OBJECT-TYPE SYNTAX INTEGER { off(0), on(1), laststate(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "set Mode of startup sequence (off, on , remember last state)" DEFVAL { off } -- 1.3.6.1.4.1.28507.6.1.2.2.1.5 ::= { epc2x6portEntry 5 } epc2x6PortStartupDelay OBJECT-TYPE SYNTAX Integer32 UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for startup action" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.6.1.2.2.1.6 ::= { epc2x6portEntry 6 } epc2x6PortRepowerTime OBJECT-TYPE SYNTAX Integer32 (0..65535) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "Delay in sec for repower port after switching off" DEFVAL { 0 } -- 1.3.6.1.4.1.28507.6.1.2.2.1.7 ::= { epc2x6portEntry 7 } epc2x6FuseEvt NOTIFICATION-TYPE OBJECTS { epc2x6portFuses} STATUS current DESCRIPTION "" -- 1.3.6.1.4.1.28507.0.13 ::= { events 13 } epc2x6TempEvt NOTIFICATION-TYPE OBJECTS { epc2x6Temperature} STATUS current DESCRIPTION "change of temperature" -- 1.3.6.1.4.1.28507.0.14 ::= { events 14 } END