-- ***************************************************************** -- EKINOPS-Pmo6006.TXT: MIB -- --MIB Part Number:3MI00036AAAC --MIB Version:02 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pmo6006-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePmo6006 MODULE-IDENTITY LAST-UPDATED "201606030000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.fr" DESCRIPTION "Creation." REVISION "201503260000Z" DESCRIPTION "Creation for PMO6006" REVISION "201503300000Z" DESCRIPTION "Creation for PMO6006" REVISION "201601290000Z" DESCRIPTION "SAPI/DAPI Acc config suppress" REVISION "201605200000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" REVISION "201606030000Z" DESCRIPTION "Capabilities objects of Table 5" ::= { ekinops 70 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmo6006alarms OBJECT IDENTIFIER ::= { modulePmo6006 2 } pmo6006AlmOther OBJECT IDENTIFIER ::= { pmo6006alarms 1 } pmo6006AlmOtherNurg OBJECT IDENTIFIER ::= { pmo6006AlmOther 1 } pmo6006AlmOtherUrg OBJECT IDENTIFIER ::= { pmo6006AlmOther 2 } pmo6006AlmOtherCrit OBJECT IDENTIFIER ::= { pmo6006AlmOther 3 } pmo6006AlmClient OBJECT IDENTIFIER ::= { pmo6006alarms 2 } pmo6006AlmClientNurg OBJECT IDENTIFIER ::= { pmo6006AlmClient 1 } pmo6006AlmClientUrg OBJECT IDENTIFIER ::= { pmo6006AlmClient 2 } pmo6006AlmClientCrit OBJECT IDENTIFIER ::= { pmo6006AlmClient 3 } pmo6006AlmLine OBJECT IDENTIFIER ::= { pmo6006alarms 3 } pmo6006AlmLineNurg OBJECT IDENTIFIER ::= { pmo6006AlmLine 1 } pmo6006AlmLineUrg OBJECT IDENTIFIER ::= { pmo6006AlmLine 2 } pmo6006AlmLineCrit OBJECT IDENTIFIER ::= { pmo6006AlmLine 3 } pmo6006measures OBJECT IDENTIFIER ::= { modulePmo6006 3 } pmo6006MesrOther OBJECT IDENTIFIER ::= { pmo6006measures 1 } pmo6006MesrClient OBJECT IDENTIFIER ::= { pmo6006measures 2 } pmo6006MesrLine OBJECT IDENTIFIER ::= { pmo6006measures 3 } pmo6006counters OBJECT IDENTIFIER ::= { modulePmo6006 4 } pmo6006CntOther OBJECT IDENTIFIER ::= { pmo6006counters 1 } pmo6006CntClient OBJECT IDENTIFIER ::= { pmo6006counters 2 } pmo6006CntLine OBJECT IDENTIFIER ::= { pmo6006counters 3 } pmo6006controlsWrite OBJECT IDENTIFIER ::= { modulePmo6006 6 } pmo6006CtrlOther OBJECT IDENTIFIER ::= { pmo6006controlsWrite 1 } pmo6006CtrlClient OBJECT IDENTIFIER ::= { pmo6006controlsWrite 2 } pmo6006CtrlLine OBJECT IDENTIFIER ::= { pmo6006controlsWrite 3 } pmo6006ri OBJECT IDENTIFIER ::= { modulePmo6006 7 } pmo6006riTable OBJECT IDENTIFIER ::= { pmo6006ri 1 } pmo6006download OBJECT IDENTIFIER ::= { modulePmo6006 8 } pmo6006DwlOther OBJECT IDENTIFIER ::= { pmo6006download 1 } pmo6006DwlClient OBJECT IDENTIFIER ::= { pmo6006download 2 } pmo6006DwlLine OBJECT IDENTIFIER ::= { pmo6006download 3 } pmo6006Config OBJECT IDENTIFIER ::= { modulePmo6006 9 } pmo6006traps OBJECT IDENTIFIER ::= { modulePmo6006 10 } pmo6006Monitoring OBJECT IDENTIFIER ::= { modulePmo6006 11} pmo6006MonOther OBJECT IDENTIFIER ::= { pmo6006Monitoring 1 } pmo6006MonRmon OBJECT IDENTIFIER ::= { pmo6006MonOther 3 } pmo6006MonClient OBJECT IDENTIFIER ::= { pmo6006Monitoring 2 } pmo6006MonClientRmonCounter OBJECT IDENTIFIER ::= { pmo6006MonClient 4 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** Pmo6006OtxGrid ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different grids on client and line ports" SYNTAX INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } Pmo6006DccMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for DCC" SYNTAX INTEGER { dccNo(0), dccLine1(1), dccLine2(2) } Pmo6006LineChannel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Channel selection on transceiver Line ports" SYNTAX INTEGER Pmo6006Odu2SapiMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for SAPI-DAPI" SYNTAX INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } Pmo6006Otu2SapiMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for SAPI-DAPI" SYNTAX INTEGER { off(0), sapi(1) dapi(2) sapidapi(3), } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmo6006RinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmo6006ri 2 } pmo6006RinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pmo6006ri 3 } pmo6006RinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmo6006ri 4 } pmo6006RinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmo6006ri 5 } pmo6006RinvGwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "GW platform description: This OID contains the description of the Gateware platform." ::= { pmo6006ri 6 } pmo6006RinvSfpTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006RinvSfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the SFPs on the selected module" ::= { pmo6006riTable 1 } pmo6006RinvSfpEntry OBJECT-TYPE SYNTAX Pmo6006RinvSfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the SFP table" INDEX { pmo6006RinvSfpIndex } ::= { pmo6006RinvSfpTable 1 } Pmo6006RinvSfpEntry::= SEQUENCE { pmo6006RinvSfpIndex Integer32, pmo6006Rinvsfp DisplayString } pmo6006RinvSfpIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for SFP table" ::= { pmo6006RinvSfpEntry 1 } pmo6006Rinvsfp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the SFP: This OID contains the inventory for the SFP" ::= { pmo6006RinvSfpEntry 2 } pmo6006RinvLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the SFPs on the selected module" ::= { pmo6006riTable 2 } pmo6006RinvLineEntry OBJECT-TYPE SYNTAX Pmo6006RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the SFP table" INDEX { pmo6006RinvLineIndex } ::= { pmo6006RinvLineTable 1 } Pmo6006RinvLineEntry::= SEQUENCE { pmo6006RinvLineIndex Integer32, pmo6006RinvxfpLine DisplayString } pmo6006RinvLineIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for SFP table" ::= { pmo6006RinvLineEntry 1 } pmo6006RinvxfpLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the XFP: This OID contains the inventory for the XFP" ::= { pmo6006RinvLineEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmo6006AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmo6006AlmOtherCrit 0 } pmo6006AlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmsynthAlm0 16 } pmo6006AlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmsynthAlm0 15 } pmo6006AlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the RM This alarm is set on detection of a failure originating from the equipment MOD_GLOB_FAIL other (1) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmo6006AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmo6006AlmOtherNurg 2 } pmo6006AlmCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This OID, when set, indicates that alarm correlation is not being performed. CORRELAT_OFF informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlm2 4 } pmo6006AlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlm2 3 } pmo6006AlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlm2 2 } pmo6006AlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlm2 1 } --- ********************************************************* --- TABLE for the pmo6006AlmsynthAlmPort articles --- ********************************************************* pmo6006AlmsynthAlmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmsynthAlmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmsynthAlmPort Article " ::= { pmo6006AlmClientCrit 8 } pmo6006AlmsynthAlmPortEntry OBJECT-TYPE SYNTAX Pmo6006AlmsynthAlmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmsynthAlmPort table " INDEX { pmo6006AlmsynthAlmPortIndex } ::= { pmo6006AlmsynthAlmPortTable 1 } Pmo6006AlmsynthAlmPortEntry ::= SEQUENCE { pmo6006AlmsynthAlmPortIndex INTEGER, pmo6006AlmUpCsfPortn EkiOnOff, pmo6006AlmFailAccPortn EkiOnOff, pmo6006AlmSfpDdmAlmPortn EkiOnOff, pmo6006AlmSfpDdmWarningPortn EkiOnOff, pmo6006AlmDwCaisPortn EkiOnOff, pmo6006AlmClientRemoteOosPortn EkiOnOff, pmo6006AlmClientLocalOosPortn EkiOnOff, pmo6006AlmDwLsdPortn EkiOnOff, pmo6006AlmHwFailAccPortn EkiOnOff, pmo6006AlmDdmAbsentPortn EkiOnOff, pmo6006AlmSfpAbsentPortn EkiOnOff } pmo6006AlmsynthAlmPortIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmsynthAlmPort table " ::= { pmo6006AlmsynthAlmPortEntry 1 } pmo6006AlmUpCsfPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. This status indicates if a Client Signal Fail is currently inserted on the line signal for this client port UP_CSF_1 informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmPortEntry 17 } pmo6006AlmFailAccPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Access Fail :This OID indicates a failure on the Client port This alarm indicates a failure on the Client port FAIL_ACC_1 equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmPortEntry 13 } pmo6006AlmSfpDdmAlmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM This alarm indicates if a DDM Alarm has been detected on the client transceiver SFP_DDM_ALM_1 inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmPortEntry 11 } pmo6006AlmSfpDdmWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM This alarm indicates if a DDM Warning has been detected on the client transceiver SFP_DDM_WARNING_1 inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmPortEntry 10 } pmo6006AlmDwCaisPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. This status indicates if a Client Alarm Indication Signal is currently inserted on the client interface DW_CAIS_1 informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmPortEntry 9 } pmo6006AlmClientRemoteOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) This status indicates if the remote client port is in service CLIENT_REMOTE_OOS informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmPortEntry 8 } pmo6006AlmClientLocalOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) This status indicates if the local client port is in service CLIENT_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmPortEntry 7 } pmo6006AlmDwLsdPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Laser Shutdown :This OID indicates the Client transceiver laser is shutdown This status indicates if the client transceiver laser is shutdown DW_LSD_1 other (1) equipmentAlarm (5) (2) " ::= { pmo6006AlmsynthAlmPortEntry 6 } pmo6006AlmHwFailAccPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. This alarm indicates a failure on client port, most probably caused by a HW issue. HW_FAIL_ACC_1 equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmPortEntry 5 } pmo6006AlmDdmAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function This status indicates if the client transceiver includes the DDM feature DDM_ABSENT_1 informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmPortEntry 3 } pmo6006AlmSfpAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Absent :This OID indicates that the Transceiver is not present in the client port. This alarm indicates if the client transceiver is not plugged SFP_ABSENT_1 inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pmo6006AlmsynthAlmPortEntry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmsynthAlmLine articles --- ********************************************************* pmo6006AlmsynthAlmLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmsynthAlmLine Article " ::= { pmo6006AlmLineCrit 24 } pmo6006AlmsynthAlmLineEntry OBJECT-TYPE SYNTAX Pmo6006AlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmsynthAlmLine table " INDEX { pmo6006AlmsynthAlmLineIndex } ::= { pmo6006AlmsynthAlmLineTable 1 } Pmo6006AlmsynthAlmLineEntry ::= SEQUENCE { pmo6006AlmsynthAlmLineIndex INTEGER, pmo6006AlmLineFailPortn EkiOnOff, pmo6006AlmLineDdmAlmPortn EkiOnOff, pmo6006AlmLineDdmWarningPortn EkiOnOff, pmo6006AlmUpRdiInsPortn EkiOnOff, pmo6006AlmLineLocalOosPortn EkiOnOff, pmo6006AlmLineTxOffPortn EkiOnOff, pmo6006AlmLineHwFailPortn EkiOnOff, pmo6006AlmLineDdmAbsentPortn EkiOnOff, pmo6006AlmLineSfpAbsentPortn EkiOnOff } pmo6006AlmsynthAlmLineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmsynthAlmLine table " ::= { pmo6006AlmsynthAlmLineEntry 1 } pmo6006AlmLineFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port This alarm indicates a failure on the line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmLineEntry 13 } pmo6006AlmLineDdmAlmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM This alarm indicates if a DDM Alarm has been detected on the line transceiver LINE_DDM_ALM inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmLineEntry 11 } pmo6006AlmLineDdmWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM This alarm indicates if a DDM Warning has been detected on the line transceiver LINE_DDM_WARNING inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmLineEntry 10 } pmo6006AlmUpRdiInsPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. This status indicates if a MS-RDI/L-RDI is currently inserted on the line interface. UP_RDI_INS informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmLineEntry 9 } pmo6006AlmLineLocalOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) This status indicates if the line port is in service LINE_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmsynthAlmLineEntry 7 } pmo6006AlmLineTxOffPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Laser Shutdown :This OID indicates the Line transceiver laser is shutdown This status indicates if the Line transceiver laser is shutdown LINE_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmo6006AlmsynthAlmLineEntry 6 } pmo6006AlmLineHwFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue This alarm indicates a failure on line port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmo6006AlmsynthAlmLineEntry 5 } pmo6006AlmLineDdmAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Ready :This OID indicates that the optical interface is not operational. This status indicates if the line transceiver has been correctly initialized LINE_DDM_ABSENT_1 equipmentMalfunction (16) other (1) (2) " ::= { pmo6006AlmsynthAlmLineEntry 3 } pmo6006AlmLineSfpAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Absent :This OID indicates that the line optical interface is not present. This alarm indicates if the line transceiver is not plugged LINE_SFP_ABSENT_1 inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pmo6006AlmsynthAlmLineEntry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmclientHostLaneFault articles --- ********************************************************* pmo6006AlmclientHostLaneFaultTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmclientHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmclientHostLaneFault Article " ::= { pmo6006AlmClientUrg 88 } pmo6006AlmclientHostLaneFaultEntry OBJECT-TYPE SYNTAX Pmo6006AlmclientHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmclientHostLaneFault table " INDEX { pmo6006AlmclientHostLaneFaultIndex } ::= { pmo6006AlmclientHostLaneFaultTable 1 } Pmo6006AlmclientHostLaneFaultEntry ::= SEQUENCE { pmo6006AlmclientHostLaneFaultIndex INTEGER, pmo6006AlmClientOdu2eDlckPortn EkiOnOff, pmo6006AlmClientOdu2eIlckPortn EkiOnOff, pmo6006AlmClientOdu2eDbdiPortn EkiOnOff, pmo6006AlmClientOdu2eIbdiPortn EkiOnOff, pmo6006AlmClientOdu2eDociPortn EkiOnOff, pmo6006AlmClientOdu2eIociPortn EkiOnOff, pmo6006AlmClientLaneTxFifoErrorPortn EkiOnOff, pmo6006AlmClientOdu2eDaisPortn EkiOnOff, pmo6006AlmClientOdu2eDtimPortn EkiOnOff, pmo6006AlmClientOdu2eIaisPortn EkiOnOff, pmo6006AlmClientCsfDetectedPortn EkiOnOff, pmo6006AlmClientOdu2eDdegPortn EkiOnOff, pmo6006AlmClientOdu2eDplmPortn EkiOnOff, pmo6006AlmClientInputLossOfSigPortn EkiOnOff, pmo6006AlmClientLossOfSyncPortn EkiOnOff } pmo6006AlmclientHostLaneFaultIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmclientHostLaneFault table " ::= { pmo6006AlmclientHostLaneFaultEntry 1 } pmo6006AlmClientOdu2eDlckPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DLCK :This OID indicates that a Locked Indication has been detected on client port This alarm indicates if a Locked Indication has been detected on the client port CLIENT_ODU2E_DLCK equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 17 } pmo6006AlmClientOdu2eIlckPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e ILCK :This OID indicates that a Locked Indication has been inserted on client port This alarm indicates if a Locked Indication has been inserted on the client port CLIENT_ODU2E_ILCK informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 16 } pmo6006AlmClientOdu2eDbdiPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DBDI :This OID indicates that a Backward Defect Indication has been detected on client port This alarm indicates if a Backward Defect Indication has been detected on the client port CLIENT_ODU2E_DBDI equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 15 } pmo6006AlmClientOdu2eIbdiPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e IBDI :This OID indicates that a Backward Defect Indication has been inserted on client port This alarm indicates if a Backward Defect Indication has been inserted on the client port CLIENT_ODU2E_IBDI informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 14 } pmo6006AlmClientOdu2eDociPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DOCI :This OID indicates that a Open Connection has been detected on client port This alarm indicates if an Open Connection Indication has been detected on the client port CLIENT_ODU2E_DOCI equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 13 } pmo6006AlmClientOdu2eIociPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e IOCI :This OID indicates that an Open Connection has been inserted on client port This alarm indicates if an Open Connection Indication has been inserted on the client port CLIENT_ODU2E_IOCI informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 12 } pmo6006AlmClientLaneTxFifoErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Alarm indicating a Tx FIFO Error on the Client Trscv CLIENT_LANE_TX_FIFO_ERROR receiverFailure (42) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 11 } pmo6006AlmClientOdu2eDaisPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DAIS :This OID indicates that a Alarm Indication SIgnal has been detected on client port This alarm indicates if an Alarm Indication Signal has been detected on the client port CLIENT_ODU2E_DAIS equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 10 } pmo6006AlmClientOdu2eDtimPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on client port This alarm indicates if an Trace Identifier Mismatch has been detected on the client port CLIENT_ODU2E_DTIM equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 9 } pmo6006AlmClientOdu2eIaisPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e IAIS :This OID indicates that an Alarm Indication Signal has been inserted on client port This alarm indicates if an Alarm Indication Signal has been inserted on the client port CLIENT_ODU2E_IAIS informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 8 } pmo6006AlmClientCsfDetectedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ETH DCSF :This OID indicates that a CSF has been detected on client port in the downstream direction This alarm indicates if a Client Signal Fail has been detected in the incoming line frame for this client port CLIENT_CSF_DETECTED receiveFailure (41) other(1) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 7 } pmo6006AlmClientOdu2eDdegPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DDEG :This OID indicates that a Signal Degrade has been detected on client port Alarm indicating a Signal Degrade upon threshold and confirmation parameters CLIENT_ODU2E_DDEG equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 6 } pmo6006AlmClientOdu2eDplmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e DPLM :This OID indicates a Payload Mismatch is detected on the Client port Alarm indicating a Payload Mismatch CLIENT_ODU2E_DPLM equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 4 } pmo6006AlmClientInputLossOfSigPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv Alarm indicating a Loss of Signal is detected on the Client Trscv CLIENT_INPUT_LOSS_OF_SIG receiveFailure (41) physicalViolation (9) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 3 } pmo6006AlmClientLossOfSyncPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal Alarm indicating the module is not aligned with the incoming client signal CLIENT_LOSS_OF_SYNC receiveFailure (41) integrityViolation (7) (2) " ::= { pmo6006AlmclientHostLaneFaultEntry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmlineNetworkLaneAlarmWarning1 articles --- ********************************************************* pmo6006AlmlineNetworkLaneAlarmWarning1Table OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmlineNetworkLaneAlarmWarning1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmlineNetworkLaneAlarmWarning1 Article " ::= { pmo6006AlmLineUrg 104 } pmo6006AlmlineNetworkLaneAlarmWarning1Entry OBJECT-TYPE SYNTAX Pmo6006AlmlineNetworkLaneAlarmWarning1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table " INDEX { pmo6006AlmlineNetworkLaneAlarmWarning1Index } ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Table 1 } Pmo6006AlmlineNetworkLaneAlarmWarning1Entry ::= SEQUENCE { pmo6006AlmlineNetworkLaneAlarmWarning1Index INTEGER, pmo6006AlmLineRxPwrHighAlaPortn EkiOnOff, pmo6006AlmLineRxPwrLowAlaPortn EkiOnOff, pmo6006AlmLineTempHighAlaPortn EkiOnOff, pmo6006AlmLineTempLowAlaPortn EkiOnOff, pmo6006AlmLineVccHighAlaPortn EkiOnOff, pmo6006AlmLineVccLowAlaPortn EkiOnOff, pmo6006AlmLineTxBiasHighAlaPortn EkiOnOff, pmo6006AlmLineTxBiasLowAlaPortn EkiOnOff, pmo6006AlmLineTxPwrHighAlaPortn EkiOnOff, pmo6006AlmLineTxPwrLowAlaPortn EkiOnOff } pmo6006AlmlineNetworkLaneAlarmWarning1Index OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmlineNetworkLaneAlarmWarning1 table " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 1 } pmo6006AlmLineRxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM LINE_RX_PWR_HIGH_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 17 } pmo6006AlmLineRxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM LINE_RX_PWR_LOW_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 16 } pmo6006AlmLineTempHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM LINE_TEMP_HIGH_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 9 } pmo6006AlmLineTempLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM LINE_TEMP_LOW_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 8 } pmo6006AlmLineVccHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM LINE_VCC_HIGH_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 7 } pmo6006AlmLineVccLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM LINE_VCC_LOW_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 6 } pmo6006AlmLineTxBiasHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 5 } pmo6006AlmLineTxBiasLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 4 } pmo6006AlmLineTxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM LINE_TX_PWR_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 3 } pmo6006AlmLineTxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM LINE_TX_PWR_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning1Entry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmlineNetworkLaneAlarmWarning2 articles --- ********************************************************* pmo6006AlmlineNetworkLaneAlarmWarning2Table OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmlineNetworkLaneAlarmWarning2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmlineNetworkLaneAlarmWarning2 Article " ::= { pmo6006AlmLineUrg 120 } pmo6006AlmlineNetworkLaneAlarmWarning2Entry OBJECT-TYPE SYNTAX Pmo6006AlmlineNetworkLaneAlarmWarning2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table " INDEX { pmo6006AlmlineNetworkLaneAlarmWarning2Index } ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Table 1 } Pmo6006AlmlineNetworkLaneAlarmWarning2Entry ::= SEQUENCE { pmo6006AlmlineNetworkLaneAlarmWarning2Index INTEGER, pmo6006AlmLineRxPwrHighWngPortn EkiOnOff, pmo6006AlmLineRxPwrLowWngPortn EkiOnOff, pmo6006AlmLineTempHighWngPortn EkiOnOff, pmo6006AlmLineTempLowWngPortn EkiOnOff, pmo6006AlmLineVccHighWngPortn EkiOnOff, pmo6006AlmLineVccLowWngPortn EkiOnOff, pmo6006AlmLineTxBiasHighWngPortn EkiOnOff, pmo6006AlmLineTxBiasLowWngPortn EkiOnOff, pmo6006AlmLineTxPwrHighWngPortn EkiOnOff, pmo6006AlmLineTxPwLowWngPortn EkiOnOff } pmo6006AlmlineNetworkLaneAlarmWarning2Index OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmlineNetworkLaneAlarmWarning2 table " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 1 } pmo6006AlmLineRxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is higher than the threshold value written in the Trscv EEPROM LINE_RX_PWR_HIGH_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 17 } pmo6006AlmLineRxPwrLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is lower than the threshold value written in the Trscv EEPROM LINE_RX_PWR_LOW_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 16 } pmo6006AlmLineTempHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM LINE_TEMP_HIGH_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 9 } pmo6006AlmLineTempLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM LINE_TEMP_LOW_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 8 } pmo6006AlmLineVccHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM LINE_VCC_HIGH_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 7 } pmo6006AlmLineVccLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM LINE_VCC_LOW_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 6 } pmo6006AlmLineTxBiasHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 5 } pmo6006AlmLineTxBiasLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 4 } pmo6006AlmLineTxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is higher than the threshold value written in the Trscv EEPROM LINE_TX_PWR_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 3 } pmo6006AlmLineTxPwLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is lower than the threshold value written in the Trscv EEPROM LINE_TX_PW_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineNetworkLaneAlarmWarning2Entry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmlineHostLaneFault articles --- ********************************************************* pmo6006AlmlineHostLaneFaultTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmlineHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmlineHostLaneFault Article " ::= { pmo6006AlmLineUrg 152 } pmo6006AlmlineHostLaneFaultEntry OBJECT-TYPE SYNTAX Pmo6006AlmlineHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmlineHostLaneFault table " INDEX { pmo6006AlmlineHostLaneFaultIndex } ::= { pmo6006AlmlineHostLaneFaultTable 1 } Pmo6006AlmlineHostLaneFaultEntry ::= SEQUENCE { pmo6006AlmlineHostLaneFaultIndex INTEGER, pmo6006AlmLineOtu2eDlomPortn EkiOnOff, pmo6006AlmLineOtu2eDssfPortn EkiOnOff, pmo6006AlmLineOchr2eDlosPPortn EkiOnOff, pmo6006AlmClientOtu2eDtimPortn EkiOnOff, pmo6006AlmOtu2eDdegPortn EkiOnOff, pmo6006AlmLineSmBdiDetectedPortn EkiOnOff, pmo6006AlmLineSmBdiInsertedPortn EkiOnOff, pmo6006AlmLineLossOfFramePortn EkiOnOff, pmo6006AlmLineInputLossOfSignalPortn EkiOnOff } pmo6006AlmlineHostLaneFaultIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmlineHostLaneFault table " ::= { pmo6006AlmlineHostLaneFaultEntry 1 } pmo6006AlmLineOtu2eDlomPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e DLOM :This OID indicates that a Loss Of Multiframe has been detected on line port This alarm indicates if a Loss Of Multiframe has been detected on the line port LINE_OTU2E_DLOM equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 17 } pmo6006AlmLineOtu2eDssfPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e DSSF :This OID indicates that a Server Signal failure has been detected on line port This alarm indicates if a Server Signal Failure has been detected on the line port LINE_OTU2E_DSSF equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 16 } pmo6006AlmLineOchr2eDlosPPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Ochr2e - DLOS-P :This OID indicates that a Transmitter failure has been detected on line port This alarm indicates if a Transmitter Failure has been detected on the line port LINE_OCHR2E_DLOS_P equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 12 } pmo6006AlmClientOtu2eDtimPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e DTIM :This OID indicates that a Trace Identifier Mismatch has been detected on line port This alarm indicates if a Trace Idenifier Mismatch has been detected on the line port CLIENT_OTU2E_DTIM equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 9 } pmo6006AlmOtu2eDdegPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e DDEG :This OID indicates that a Signal Degrade has been detected on line port This alarm indicates if a Signal Degrade has been detected upon threshold and confirmation parameters on the line port OTU2E_DDEG equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 8 } pmo6006AlmLineSmBdiDetectedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e DBDI :This OID indicates a SM Backward Defect Indication is detected on the incoming Line signal This alarm indicates if a Backward Defect Indication has been detected on the line port LINE_SM_BDI_DETECTED receiveFailure (41) integrityViolation (7) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 5 } pmo6006AlmLineSmBdiInsertedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e IBDI :This OID indicates a SM Backward Defect Indication is inserted on the outgoing Line signal This alarm indicates if a Backward Defect Indication has been inserted on the line port LINE_SM_BDI_INSERTED informationalStatus(1000) other (1) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 4 } pmo6006AlmLineLossOfFramePortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e - DLOF :This OID indicates the module is not aligned with the incoming Line signal This alarm indicates if a Loss Of Frame has been detected on the line port LINE_LOSS_OF_FRAME receiveFailure (41) integrityViolation (7) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 3 } pmo6006AlmLineInputLossOfSignalPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " OPS2e DLOS-P :This OID indicates a Loss of Signal is detected on the Line Trscv This alarm indicates if an Optical Path Break has been detected on the line port LINE_INPUT_LOSS_OF_SIGNAL receiveFailure (41) physicalViolation (9) (2) " ::= { pmo6006AlmlineHostLaneFaultEntry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmclientSfpAlmDdm articles --- ********************************************************* pmo6006AlmclientSfpAlmDdmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmclientSfpAlmDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmclientSfpAlmDdm Article " ::= { pmo6006AlmClientUrg 216 } pmo6006AlmclientSfpAlmDdmEntry OBJECT-TYPE SYNTAX Pmo6006AlmclientSfpAlmDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmclientSfpAlmDdm table " INDEX { pmo6006AlmclientSfpAlmDdmIndex } ::= { pmo6006AlmclientSfpAlmDdmTable 1 } Pmo6006AlmclientSfpAlmDdmEntry ::= SEQUENCE { pmo6006AlmclientSfpAlmDdmIndex INTEGER, pmo6006AlmClientRxPwrHighAlaPortn EkiOnOff, pmo6006AlmClientRxPwrLowAlaPortn EkiOnOff, pmo6006AlmClientTempHighAlaPortn EkiOnOff, pmo6006AlmClientTempLowAlaPortn EkiOnOff, pmo6006AlmClientVccHighAlaPortn EkiOnOff, pmo6006AlmClientVccLowAlaPortn EkiOnOff, pmo6006AlmClientTxBiasHighAlaPortn EkiOnOff, pmo6006AlmClientTxBiasLowAlaPortn EkiOnOff, pmo6006AlmClientTxPwrHighAlaPortn EkiOnOff, pmo6006AlmClientTxPwrLowAlaPortn EkiOnOff } pmo6006AlmclientSfpAlmDdmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmclientSfpAlmDdm table " ::= { pmo6006AlmclientSfpAlmDdmEntry 1 } pmo6006AlmClientRxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_HIGH_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 17 } pmo6006AlmClientRxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_LOW_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 16 } pmo6006AlmClientTempHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TEMP_HIGH_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 9 } pmo6006AlmClientTempLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TEMP_LOW_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 8 } pmo6006AlmClientVccHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM CLIENT_VCC_HIGH_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 7 } pmo6006AlmClientVccLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM CLIENT_VCC_LOW_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 6 } pmo6006AlmClientTxBiasHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 5 } pmo6006AlmClientTxBiasLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 4 } pmo6006AlmClientTxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 3 } pmo6006AlmClientTxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpAlmDdmEntry 2 } --- ********************************************************* --- TABLE for the pmo6006AlmclientSfpWarnDdm articles --- ********************************************************* pmo6006AlmclientSfpWarnDdmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006AlmclientSfpWarnDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006AlmclientSfpWarnDdm Article " ::= { pmo6006AlmClientNurg 232 } pmo6006AlmclientSfpWarnDdmEntry OBJECT-TYPE SYNTAX Pmo6006AlmclientSfpWarnDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006AlmclientSfpWarnDdm table " INDEX { pmo6006AlmclientSfpWarnDdmIndex } ::= { pmo6006AlmclientSfpWarnDdmTable 1 } Pmo6006AlmclientSfpWarnDdmEntry ::= SEQUENCE { pmo6006AlmclientSfpWarnDdmIndex INTEGER, pmo6006AlmClientRxPwrHighWngPortn EkiOnOff, pmo6006AlmClientRxPwrLowWngPortn EkiOnOff, pmo6006AlmClientTempHighWngPortn EkiOnOff, pmo6006AlmClientTempLowWngPortn EkiOnOff, pmo6006AlmClientVccHighWngPortn EkiOnOff, pmo6006AlmClientVccLowWngPortn EkiOnOff, pmo6006AlmClientTxBiasHighWngPortn EkiOnOff, pmo6006AlmClientTxBiasLowWngPortn EkiOnOff, pmo6006AlmClientTxPwrHighWngPortn EkiOnOff, pmo6006AlmClientTxPwLowWngPortn EkiOnOff } pmo6006AlmclientSfpWarnDdmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006AlmclientSfpWarnDdm table " ::= { pmo6006AlmclientSfpWarnDdmEntry 1 } pmo6006AlmClientRxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is higher than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_HIGH_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 17 } pmo6006AlmClientRxPwrLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is lower than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_LOW_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 16 } pmo6006AlmClientTempHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM CLIENT_TEMP_HIGH_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 9 } pmo6006AlmClientTempLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM CLIENT_TEMP_LOW_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 8 } pmo6006AlmClientVccHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM CLIENT_VCC_HIGH_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 7 } pmo6006AlmClientVccLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM CLIENT_VCC_LOW_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 6 } pmo6006AlmClientTxBiasHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 5 } pmo6006AlmClientTxBiasLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 4 } pmo6006AlmClientTxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 3 } pmo6006AlmClientTxPwLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_PW_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmo6006AlmclientSfpWarnDdmEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the confMgnt1 article --- ***************************************************** pmo6006CtrlconfMgnt1 OBJECT IDENTIFIER ::= { pmo6006CtrlOther 1 } pmo6006CtrlConf2Clear1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. This control restores the default configuration of the module " ::= { pmo6006CtrlconfMgnt1 14 } pmo6006CtrlConf2Flash1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. This control saves the customer configuration on the module " ::= { pmo6006CtrlconfMgnt1 10 } pmo6006CtrlConf2Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. " ::= { pmo6006CtrlconfMgnt1 2 } pmo6006CtrlConf1Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. " ::= { pmo6006CtrlconfMgnt1 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pmo6006Ctrlsynth4 OBJECT IDENTIFIER ::= { pmo6006CtrlOther 4 } pmo6006CtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM. " ::= { pmo6006Ctrlsynth4 2 } pmo6006CtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM. " ::= { pmo6006Ctrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmo6006CtrlswMgnt OBJECT IDENTIFIER ::= { pmo6006CtrlOther 5 } pmo6006CtrlLoadSwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. This controls selects the second SW bank as the active bank for the next module reset " ::= { pmo6006CtrlswMgnt 6 } pmo6006CtrlLoadSwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. This controls selects the first SW bank as the active bank for the next module reset " ::= { pmo6006CtrlswMgnt 5 } pmo6006CtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. This control initiates a warm reset of the module. " ::= { pmo6006CtrlswMgnt 3 } pmo6006CtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmo6006CtrlswMgnt 2 } --- ***************************************************** --- LEAF for the gwMgnt article --- ***************************************************** pmo6006CtrlgwMgnt OBJECT IDENTIFIER ::= { pmo6006CtrlOther 6 } pmo6006CtrlLoadGwBank4 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pmo6006CtrlgwMgnt 8 } pmo6006CtrlLoadGwBank3 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the third GW bank as the active bank " ::= { pmo6006CtrlgwMgnt 7 } pmo6006CtrlLoadGwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pmo6006CtrlgwMgnt 6 } pmo6006CtrlLoadGwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the first GW bank as the active bank " ::= { pmo6006CtrlgwMgnt 5 } pmo6006CtrlCurrentGwReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. " ::= { pmo6006CtrlgwMgnt 1 } --- ********************************************************* --- TABLE for the pmo6006CtrlaccessLoop articles --- ********************************************************* pmo6006CtrlaccessLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlaccessLoop Article " ::= { pmo6006CtrlClient 16 } pmo6006CtrlaccessLoopEntry OBJECT-TYPE SYNTAX Pmo6006CtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlaccessLoop table " INDEX { pmo6006CtrlaccessLoopIndex } ::= { pmo6006CtrlaccessLoopTable 1 } Pmo6006CtrlaccessLoopEntry ::= SEQUENCE { pmo6006CtrlaccessLoopIndex INTEGER, pmo6006CtrlaccessLoopPortn EkiState } pmo6006CtrlaccessLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlaccessLoop table " ::= { pmo6006CtrlaccessLoopEntry 1 } pmo6006CtrlaccessLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. This control enables the Out Loopback on the client port, looping the client input signal on the client output " ::= { pmo6006CtrlaccessLoopEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlclientLoopToLine articles --- ********************************************************* pmo6006CtrlclientLoopToLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlclientLoopToLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlclientLoopToLine Article " ::= { pmo6006CtrlClient 17 } pmo6006CtrlclientLoopToLineEntry OBJECT-TYPE SYNTAX Pmo6006CtrlclientLoopToLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlclientLoopToLine table " INDEX { pmo6006CtrlclientLoopToLineIndex } ::= { pmo6006CtrlclientLoopToLineTable 1 } Pmo6006CtrlclientLoopToLineEntry ::= SEQUENCE { pmo6006CtrlclientLoopToLineIndex INTEGER, pmo6006CtrlclientLoopToLinePortn EkiState } pmo6006CtrlclientLoopToLineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlclientLoopToLine table " ::= { pmo6006CtrlclientLoopToLineEntry 1 } pmo6006CtrlclientLoopToLinePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. This control enables the In Loopback on the client port, looping the client output signal on the client input " ::= { pmo6006CtrlclientLoopToLineEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlcsfUpIns articles --- ********************************************************* pmo6006CtrlcsfUpInsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlcsfUpInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlcsfUpIns Article " ::= { pmo6006CtrlClient 21 } pmo6006CtrlcsfUpInsEntry OBJECT-TYPE SYNTAX Pmo6006CtrlcsfUpInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlcsfUpIns table " INDEX { pmo6006CtrlcsfUpInsIndex } ::= { pmo6006CtrlcsfUpInsTable 1 } Pmo6006CtrlcsfUpInsEntry ::= SEQUENCE { pmo6006CtrlcsfUpInsIndex INTEGER, pmo6006CtrlcsfUpInsPortn EkiState } pmo6006CtrlcsfUpInsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlcsfUpIns table " ::= { pmo6006CtrlcsfUpInsEntry 1 } pmo6006CtrlcsfUpInsPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. This control inserts a Client Signal Fail for the client port " ::= { pmo6006CtrlcsfUpInsEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlcaisDwIns articles --- ********************************************************* pmo6006CtrlcaisDwInsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlcaisDwInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlcaisDwIns Article " ::= { pmo6006CtrlClient 22 } pmo6006CtrlcaisDwInsEntry OBJECT-TYPE SYNTAX Pmo6006CtrlcaisDwInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlcaisDwIns table " INDEX { pmo6006CtrlcaisDwInsIndex } ::= { pmo6006CtrlcaisDwInsTable 1 } Pmo6006CtrlcaisDwInsEntry ::= SEQUENCE { pmo6006CtrlcaisDwInsIndex INTEGER, pmo6006CtrlcaisDwInsPortn EkiState } pmo6006CtrlcaisDwInsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlcaisDwIns table " ::= { pmo6006CtrlcaisDwInsEntry 1 } pmo6006CtrlcaisDwInsPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. This control inserts a Client AIS for the client port " ::= { pmo6006CtrlcaisDwInsEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlclientOci articles --- ********************************************************* pmo6006CtrlclientOciTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlclientOciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlclientOci Article " ::= { pmo6006CtrlClient 23 } pmo6006CtrlclientOciEntry OBJECT-TYPE SYNTAX Pmo6006CtrlclientOciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlclientOci table " INDEX { pmo6006CtrlclientOciIndex } ::= { pmo6006CtrlclientOciTable 1 } Pmo6006CtrlclientOciEntry ::= SEQUENCE { pmo6006CtrlclientOciIndex INTEGER, pmo6006CtrlclientOciPortn EkiState } pmo6006CtrlclientOciIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlclientOci table " ::= { pmo6006CtrlclientOciEntry 1 } pmo6006CtrlclientOciPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-OCI :Label This control inserts a Client OCI " ::= { pmo6006CtrlclientOciEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlclientLck articles --- ********************************************************* pmo6006CtrlclientLckTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlclientLckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlclientLck Article " ::= { pmo6006CtrlClient 24 } pmo6006CtrlclientLckEntry OBJECT-TYPE SYNTAX Pmo6006CtrlclientLckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlclientLck table " INDEX { pmo6006CtrlclientLckIndex } ::= { pmo6006CtrlclientLckTable 1 } Pmo6006CtrlclientLckEntry ::= SEQUENCE { pmo6006CtrlclientLckIndex INTEGER, pmo6006CtrlclientLckPortn EkiState } pmo6006CtrlclientLckIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlclientLck table " ::= { pmo6006CtrlclientLckEntry 1 } pmo6006CtrlclientLckPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-LCK :Label This control inserts a Client LCK " ::= { pmo6006CtrlclientLckEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlclientAis articles --- ********************************************************* pmo6006CtrlclientAisTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlclientAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlclientAis Article " ::= { pmo6006CtrlClient 25 } pmo6006CtrlclientAisEntry OBJECT-TYPE SYNTAX Pmo6006CtrlclientAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlclientAis table " INDEX { pmo6006CtrlclientAisIndex } ::= { pmo6006CtrlclientAisTable 1 } Pmo6006CtrlclientAisEntry ::= SEQUENCE { pmo6006CtrlclientAisIndex INTEGER, pmo6006CtrlclientAisPortn EkiState } pmo6006CtrlclientAisIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlclientAis table " ::= { pmo6006CtrlclientAisEntry 1 } pmo6006CtrlclientAisPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-AIS :Label This control inserts a Client AIS " ::= { pmo6006CtrlclientAisEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlclientBdi articles --- ********************************************************* pmo6006CtrlclientBdiTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlclientBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlclientBdi Article " ::= { pmo6006CtrlClient 26 } pmo6006CtrlclientBdiEntry OBJECT-TYPE SYNTAX Pmo6006CtrlclientBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlclientBdi table " INDEX { pmo6006CtrlclientBdiIndex } ::= { pmo6006CtrlclientBdiTable 1 } Pmo6006CtrlclientBdiEntry ::= SEQUENCE { pmo6006CtrlclientBdiIndex INTEGER, pmo6006CtrlclientBdiPortn EkiState } pmo6006CtrlclientBdiIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlclientBdi table " ::= { pmo6006CtrlclientBdiEntry 1 } pmo6006CtrlclientBdiPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-BDI :Label This control inserts a Client BDI " ::= { pmo6006CtrlclientBdiEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlcommAccessLoop articles --- ********************************************************* pmo6006CtrlcommAccessLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlcommAccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlcommAccessLoop Article " ::= { pmo6006CtrlLine 64 } pmo6006CtrlcommAccessLoopEntry OBJECT-TYPE SYNTAX Pmo6006CtrlcommAccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlcommAccessLoop table " INDEX { pmo6006CtrlcommAccessLoopIndex } ::= { pmo6006CtrlcommAccessLoopTable 1 } Pmo6006CtrlcommAccessLoopEntry ::= SEQUENCE { pmo6006CtrlcommAccessLoopIndex INTEGER, pmo6006CtrlcommAccessLoopPortn EkiState } pmo6006CtrlcommAccessLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlcommAccessLoop table " ::= { pmo6006CtrlcommAccessLoopEntry 1 } pmo6006CtrlcommAccessLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. This control enables the In Loopback on the line port, looping the 100 Gb/s output signal on the 100 Gb/s input " ::= { pmo6006CtrlcommAccessLoopEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrllineLoop articles --- ********************************************************* pmo6006CtrllineLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrllineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrllineLoop Article " ::= { pmo6006CtrlLine 66 } pmo6006CtrllineLoopEntry OBJECT-TYPE SYNTAX Pmo6006CtrllineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrllineLoop table " INDEX { pmo6006CtrllineLoopIndex } ::= { pmo6006CtrllineLoopTable 1 } Pmo6006CtrllineLoopEntry ::= SEQUENCE { pmo6006CtrllineLoopIndex INTEGER, pmo6006CtrllineLoopPortn EkiState } pmo6006CtrllineLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrllineLoop table " ::= { pmo6006CtrllineLoopEntry 1 } pmo6006CtrllineLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Upstream part of the module is timed on the 10 Gb/s recovered clock in that case. This control enables the Out Loopback on the line port, looping the 100 Gb/s input signal on the 100 Gb/s output " ::= { pmo6006CtrllineLoopEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrlfecDisable articles --- ********************************************************* pmo6006CtrlfecDisableTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrlfecDisable Article " ::= { pmo6006CtrlLine 69 } pmo6006CtrlfecDisableEntry OBJECT-TYPE SYNTAX Pmo6006CtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrlfecDisable table " INDEX { pmo6006CtrlfecDisableIndex } ::= { pmo6006CtrlfecDisableTable 1 } Pmo6006CtrlfecDisableEntry ::= SEQUENCE { pmo6006CtrlfecDisableIndex INTEGER, pmo6006CtrlfecDisablePortn EkiState } pmo6006CtrlfecDisableIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrlfecDisable table " ::= { pmo6006CtrlfecDisableEntry 1 } pmo6006CtrlfecDisablePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input This control enables/disables the Forward Error Correction on the line interface " ::= { pmo6006CtrlfecDisableEntry 2 } --- ********************************************************* --- TABLE for the pmo6006CtrllineBdi articles --- ********************************************************* pmo6006CtrllineBdiTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CtrllineBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CtrllineBdi Article " ::= { pmo6006CtrlLine 70 } pmo6006CtrllineBdiEntry OBJECT-TYPE SYNTAX Pmo6006CtrllineBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CtrllineBdi table " INDEX { pmo6006CtrllineBdiIndex } ::= { pmo6006CtrllineBdiTable 1 } Pmo6006CtrllineBdiEntry ::= SEQUENCE { pmo6006CtrllineBdiIndex INTEGER, pmo6006CtrllineBdiPortn EkiState } pmo6006CtrllineBdiIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CtrllineBdi table " ::= { pmo6006CtrllineBdiEntry 1 } pmo6006CtrllineBdiPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2e-BDI :Label This control inserts a Line BDI " ::= { pmo6006CtrllineBdiEntry 2 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmo6006CtrlledTest OBJECT IDENTIFIER ::= { pmo6006CtrlOther 192 } pmo6006CtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmo6006CtrlledTest 3 } pmo6006CtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmo6006CtrlledTest 2 } pmo6006CtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmo6006CtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- COUNTERS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pmo6006CntclientRemoteBip articles --- ********************************************************* pmo6006CntclientRemoteBipTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntclientRemoteBipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntclientRemoteBip Article " ::= { pmo6006CntClient 64 } pmo6006CntclientRemoteBipEntry OBJECT-TYPE SYNTAX Pmo6006CntclientRemoteBipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntclientRemoteBip table " INDEX { pmo6006CntclientRemoteBipIndex } ::= { pmo6006CntclientRemoteBipTable 1 } Pmo6006CntclientRemoteBipEntry ::= SEQUENCE { pmo6006CntclientRemoteBipIndex INTEGER, pmo6006CntclientRemoteBipValuePortn Counter32, pmo6006CntclientRemoteBipErrorPortn EkiOnOff, pmo6006CntclientRemoteBipOverloadPortn EkiOnOff } pmo6006CntclientRemoteBipIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntclientRemoteBip table " ::= { pmo6006CntclientRemoteBipEntry 1 } pmo6006CntclientRemoteBipValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e_Sk_pF_EBC :This counter is increased each time a BIP8 error is detected on the Client input stream This counter gives the number of BIP8 errors on the remote client path " ::= { pmo6006CntclientRemoteBipEntry 2 } pmo6006CntclientRemoteBipErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Counter Error :This OID when set indicates the BIP8 error counter value is invalid on Port " ::= { pmo6006CntclientRemoteBipEntry 3 } pmo6006CntclientRemoteBipOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Counter Overload :This OID when set indicates a BIP8 error counter overload on Port " ::= { pmo6006CntclientRemoteBipEntry 4 } --- ********************************************************* --- TABLE for the pmo6006CntclientCbipCounter articles --- ********************************************************* pmo6006CntclientCbipCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntclientCbipCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntclientCbipCounter Article " ::= { pmo6006CntClient 96 } pmo6006CntclientCbipCounterEntry OBJECT-TYPE SYNTAX Pmo6006CntclientCbipCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntclientCbipCounter table " INDEX { pmo6006CntclientCbipCounterIndex } ::= { pmo6006CntclientCbipCounterTable 1 } Pmo6006CntclientCbipCounterEntry ::= SEQUENCE { pmo6006CntclientCbipCounterIndex INTEGER, pmo6006CntclientCbipCounterValuePortn Counter32, pmo6006CntclientCbipCounterErrorPortn EkiOnOff, pmo6006CntclientCbipCounterOverloadPortn EkiOnOff } pmo6006CntclientCbipCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntclientCbipCounter table " ::= { pmo6006CntclientCbipCounterEntry 1 } pmo6006CntclientCbipCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " ODU2e_Sk_pN_EBC :This counter is incremented each time a BI8P error is detected on the Client path This counter gives the number of BIP8 errors on the client path " ::= { pmo6006CntclientCbipCounterEntry 2 } pmo6006CntclientCbipCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port " ::= { pmo6006CntclientCbipCounterEntry 3 } pmo6006CntclientCbipCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port " ::= { pmo6006CntclientCbipCounterEntry 4 } --- ********************************************************* --- TABLE for the pmo6006CntlocalLineSmBip8ErrorCounter articles --- ********************************************************* pmo6006CntlocalLineSmBip8ErrorCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntlocalLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntlocalLineSmBip8ErrorCounter Article " ::= { pmo6006CntLine 192 } pmo6006CntlocalLineSmBip8ErrorCounterEntry OBJECT-TYPE SYNTAX Pmo6006CntlocalLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntlocalLineSmBip8ErrorCounter table " INDEX { pmo6006CntlocalLineSmBip8ErrorCounterIndex } ::= { pmo6006CntlocalLineSmBip8ErrorCounterTable 1 } Pmo6006CntlocalLineSmBip8ErrorCounterEntry ::= SEQUENCE { pmo6006CntlocalLineSmBip8ErrorCounterIndex INTEGER, pmo6006CntlocalLineSmBip8ErrorCounterValuePortn Counter32, pmo6006CntlocalLineSmBip8ErrorCounterErrorPortn EkiOnOff, pmo6006CntlocalLineSmBip8ErrorCounterOverloadPortn EkiOnOff } pmo6006CntlocalLineSmBip8ErrorCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntlocalLineSmBip8ErrorCounter table " ::= { pmo6006CntlocalLineSmBip8ErrorCounterEntry 1 } pmo6006CntlocalLineSmBip8ErrorCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e_Sk_pN_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC This counter gives the current Bit Error Rate (residual SM-BIP8 error) after FEC " ::= { pmo6006CntlocalLineSmBip8ErrorCounterEntry 2 } pmo6006CntlocalLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port " ::= { pmo6006CntlocalLineSmBip8ErrorCounterEntry 3 } pmo6006CntlocalLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a B1 error counter overload on Port " ::= { pmo6006CntlocalLineSmBip8ErrorCounterEntry 4 } --- ********************************************************* --- TABLE for the pmo6006CntlocalLineFecCorrectedErrorsCounter articles --- ********************************************************* pmo6006CntlocalLineFecCorrectedErrorsCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntlocalLineFecCorrectedErrorsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntlocalLineFecCorrectedErrorsCounter Article " ::= { pmo6006CntLine 200 } pmo6006CntlocalLineFecCorrectedErrorsCounterEntry OBJECT-TYPE SYNTAX Pmo6006CntlocalLineFecCorrectedErrorsCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table " INDEX { pmo6006CntlocalLineFecCorrectedErrorsCounterIndex } ::= { pmo6006CntlocalLineFecCorrectedErrorsCounterTable 1 } Pmo6006CntlocalLineFecCorrectedErrorsCounterEntry ::= SEQUENCE { pmo6006CntlocalLineFecCorrectedErrorsCounterIndex INTEGER, pmo6006CntlocalLineFecCorrectedErrorsCounterValuePortn Counter32, pmo6006CntlocalLineFecCorrectedErrorsCounterErrorPortn EkiOnOff, pmo6006CntlocalLineFecCorrectedErrorsCounterOverloadPortn EkiOnOff } pmo6006CntlocalLineFecCorrectedErrorsCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntlocalLineFecCorrectedErrorsCounter table " ::= { pmo6006CntlocalLineFecCorrectedErrorsCounterEntry 1 } pmo6006CntlocalLineFecCorrectedErrorsCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " OCh/OTU2e-Sk_pFECcorrErr :This OID gives the current Bit Error Rate before the Hard Decision FEC This counter gives the current Bit Error Rate before the Hard Decision FEC " ::= { pmo6006CntlocalLineFecCorrectedErrorsCounterEntry 2 } pmo6006CntlocalLineFecCorrectedErrorsCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " FEC Counter Error :This bit when set indicates the FEC corrected errors counter value is invalid on Line " ::= { pmo6006CntlocalLineFecCorrectedErrorsCounterEntry 3 } pmo6006CntlocalLineFecCorrectedErrorsCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " FEC Counter Overload :This bit when set indicates a FEC corrected errors counter overload on Line " ::= { pmo6006CntlocalLineFecCorrectedErrorsCounterEntry 4 } --- ********************************************************* --- TABLE for the pmo6006CntremoteLineSmBip8ErrorCounter articles --- ********************************************************* pmo6006CntremoteLineSmBip8ErrorCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntremoteLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntremoteLineSmBip8ErrorCounter Article " ::= { pmo6006CntLine 208 } pmo6006CntremoteLineSmBip8ErrorCounterEntry OBJECT-TYPE SYNTAX Pmo6006CntremoteLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntremoteLineSmBip8ErrorCounter table " INDEX { pmo6006CntremoteLineSmBip8ErrorCounterIndex } ::= { pmo6006CntremoteLineSmBip8ErrorCounterTable 1 } Pmo6006CntremoteLineSmBip8ErrorCounterEntry ::= SEQUENCE { pmo6006CntremoteLineSmBip8ErrorCounterIndex INTEGER, pmo6006CntremoteLineSmBip8ErrorCounterValuePortn Counter32, pmo6006CntremoteLineSmBip8ErrorCounterErrorPortn EkiOnOff, pmo6006CntremoteLineSmBip8ErrorCounterOverloadPortn EkiOnOff } pmo6006CntremoteLineSmBip8ErrorCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntremoteLineSmBip8ErrorCounter table " ::= { pmo6006CntremoteLineSmBip8ErrorCounterEntry 1 } pmo6006CntremoteLineSmBip8ErrorCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " OTU2e_Sk_pF_EBC :This OID gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side This counter gives the current Bit Error Rate (residual SM-BIP8 error) after FEC on the remote side " ::= { pmo6006CntremoteLineSmBip8ErrorCounterEntry 2 } pmo6006CntremoteLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Remote Counter Error : " ::= { pmo6006CntremoteLineSmBip8ErrorCounterEntry 3 } pmo6006CntremoteLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Remote Counter Overload : " ::= { pmo6006CntremoteLineSmBip8ErrorCounterEntry 4 } --- ********************************************************* --- TABLE for the pmo6006CntlineDfrmTimCnt articles --- ********************************************************* pmo6006CntlineDfrmTimCntTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CntlineDfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006CntlineDfrmTimCnt Article " ::= { pmo6006CntLine 216 } pmo6006CntlineDfrmTimCntEntry OBJECT-TYPE SYNTAX Pmo6006CntlineDfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006CntlineDfrmTimCnt table " INDEX { pmo6006CntlineDfrmTimCntIndex } ::= { pmo6006CntlineDfrmTimCntTable 1 } Pmo6006CntlineDfrmTimCntEntry ::= SEQUENCE { pmo6006CntlineDfrmTimCntIndex INTEGER, pmo6006CntlineDfrmTimCntValuePortn Counter32, pmo6006CntlineDfrmTimCntErrorPortn EkiOnOff, pmo6006CntlineDfrmTimCntOverloadPortn EkiOnOff } pmo6006CntlineDfrmTimCntIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006CntlineDfrmTimCnt table " ::= { pmo6006CntlineDfrmTimCntEntry 1 } pmo6006CntlineDfrmTimCntValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Timer Counter : " ::= { pmo6006CntlineDfrmTimCntEntry 2 } pmo6006CntlineDfrmTimCntErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port " ::= { pmo6006CntlineDfrmTimCntEntry 3 } pmo6006CntlineDfrmTimCntOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port " ::= { pmo6006CntlineDfrmTimCntEntry 4 } pmo6006CntCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters Reset:This OID resets and restarts all the counters" ::= { pmo6006counters 259 } pmo6006CntCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters stop:This OID stops all the counters" ::= { pmo6006counters 260 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- RMON --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pmo6006MonupRmonBytesCounterClientInput articles --- ********************************************************* pmo6006MonupRmonBytesCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonBytesCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonBytesCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 16 } pmo6006MonupRmonBytesCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonBytesCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonBytesCounterClientInput table " INDEX { pmo6006MonupRmonBytesCounterClientInputIndex } ::= { pmo6006MonupRmonBytesCounterClientInputTable 1 } Pmo6006MonupRmonBytesCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonBytesCounterClientInputIndex INTEGER, pmo6006MonupRmonBytesCounterClientInputValuePortn Counter64, pmo6006MonupRmonBytesCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonBytesCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonBytesCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonBytesCounterClientInput table " ::= { pmo6006MonupRmonBytesCounterClientInputEntry 1 } pmo6006MonupRmonBytesCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Bytes :This counter is increased each time a data byte is received on the client port This counter gives the number of bytes received on the client port " ::= { pmo6006MonupRmonBytesCounterClientInputEntry 2 } pmo6006MonupRmonBytesCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port " ::= { pmo6006MonupRmonBytesCounterClientInputEntry 3 } pmo6006MonupRmonBytesCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port " ::= { pmo6006MonupRmonBytesCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MonupRmonCrcErrorsCounterClientInput articles --- ********************************************************* pmo6006MonupRmonCrcErrorsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonCrcErrorsCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 32 } pmo6006MonupRmonCrcErrorsCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table " INDEX { pmo6006MonupRmonCrcErrorsCounterClientInputIndex } ::= { pmo6006MonupRmonCrcErrorsCounterClientInputTable 1 } Pmo6006MonupRmonCrcErrorsCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonCrcErrorsCounterClientInputIndex INTEGER, pmo6006MonupRmonCrcErrorsCounterClientInputValuePortn Counter64, pmo6006MonupRmonCrcErrorsCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonCrcErrorsCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonCrcErrorsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonCrcErrorsCounterClientInput table " ::= { pmo6006MonupRmonCrcErrorsCounterClientInputEntry 1 } pmo6006MonupRmonCrcErrorsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port This counter gives the number of B1/FCS Errors received on the client port " ::= { pmo6006MonupRmonCrcErrorsCounterClientInputEntry 2 } pmo6006MonupRmonCrcErrorsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " B1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port " ::= { pmo6006MonupRmonCrcErrorsCounterClientInputEntry 3 } pmo6006MonupRmonCrcErrorsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " B1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port " ::= { pmo6006MonupRmonCrcErrorsCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MonupRmonPacketsCounterClientInput articles --- ********************************************************* pmo6006MonupRmonPacketsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonPacketsCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 48 } pmo6006MonupRmonPacketsCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonPacketsCounterClientInput table " INDEX { pmo6006MonupRmonPacketsCounterClientInputIndex } ::= { pmo6006MonupRmonPacketsCounterClientInputTable 1 } Pmo6006MonupRmonPacketsCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonPacketsCounterClientInputIndex INTEGER, pmo6006MonupRmonPacketsCounterClientInputValuePortn Counter64, pmo6006MonupRmonPacketsCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonPacketsCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonPacketsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonPacketsCounterClientInput table " ::= { pmo6006MonupRmonPacketsCounterClientInputEntry 1 } pmo6006MonupRmonPacketsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Packets :This counter is increased each time a packet is received on the client port This counter gives the number of packets received on the client port " ::= { pmo6006MonupRmonPacketsCounterClientInputEntry 2 } pmo6006MonupRmonPacketsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port " ::= { pmo6006MonupRmonPacketsCounterClientInputEntry 3 } pmo6006MonupRmonPacketsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Packets Counter Overload :This OID when set indicates a Packets counter overload on client port " ::= { pmo6006MonupRmonPacketsCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MonupRmonBroadcastCounterClientInput articles --- ********************************************************* pmo6006MonupRmonBroadcastCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonBroadcastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonBroadcastCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 64 } pmo6006MonupRmonBroadcastCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonBroadcastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonBroadcastCounterClientInput table " INDEX { pmo6006MonupRmonBroadcastCounterClientInputIndex } ::= { pmo6006MonupRmonBroadcastCounterClientInputTable 1 } Pmo6006MonupRmonBroadcastCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonBroadcastCounterClientInputIndex INTEGER, pmo6006MonupRmonBroadcastCounterClientInputValuePortn Counter64, pmo6006MonupRmonBroadcastCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonBroadcastCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonBroadcastCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonBroadcastCounterClientInput table " ::= { pmo6006MonupRmonBroadcastCounterClientInputEntry 1 } pmo6006MonupRmonBroadcastCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port This counter gives the number of Broadcast packets received on the client port " ::= { pmo6006MonupRmonBroadcastCounterClientInputEntry 2 } pmo6006MonupRmonBroadcastCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port " ::= { pmo6006MonupRmonBroadcastCounterClientInputEntry 3 } pmo6006MonupRmonBroadcastCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port " ::= { pmo6006MonupRmonBroadcastCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MonupRmonMulticastCounterClientInput articles --- ********************************************************* pmo6006MonupRmonMulticastCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonMulticastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonMulticastCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 80 } pmo6006MonupRmonMulticastCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonMulticastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonMulticastCounterClientInput table " INDEX { pmo6006MonupRmonMulticastCounterClientInputIndex } ::= { pmo6006MonupRmonMulticastCounterClientInputTable 1 } Pmo6006MonupRmonMulticastCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonMulticastCounterClientInputIndex INTEGER, pmo6006MonupRmonMulticastCounterClientInputValuePortn Counter64, pmo6006MonupRmonMulticastCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonMulticastCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonMulticastCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonMulticastCounterClientInput table " ::= { pmo6006MonupRmonMulticastCounterClientInputEntry 1 } pmo6006MonupRmonMulticastCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port This counter gives the number of Multicast packets received on the client port " ::= { pmo6006MonupRmonMulticastCounterClientInputEntry 2 } pmo6006MonupRmonMulticastCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port " ::= { pmo6006MonupRmonMulticastCounterClientInputEntry 3 } pmo6006MonupRmonMulticastCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port " ::= { pmo6006MonupRmonMulticastCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MonupRmonPauseFrameCounterClientInput articles --- ********************************************************* pmo6006MonupRmonPauseFrameCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MonupRmonPauseFrameCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MonupRmonPauseFrameCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 96 } pmo6006MonupRmonPauseFrameCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MonupRmonPauseFrameCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MonupRmonPauseFrameCounterClientInput table " INDEX { pmo6006MonupRmonPauseFrameCounterClientInputIndex } ::= { pmo6006MonupRmonPauseFrameCounterClientInputTable 1 } Pmo6006MonupRmonPauseFrameCounterClientInputEntry ::= SEQUENCE { pmo6006MonupRmonPauseFrameCounterClientInputIndex INTEGER, pmo6006MonupRmonPauseFrameCounterClientInputValuePortn Counter64, pmo6006MonupRmonPauseFrameCounterClientInputErrorPortn EkiOnOff, pmo6006MonupRmonPauseFrameCounterClientInputOverloadPortn EkiOnOff } pmo6006MonupRmonPauseFrameCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MonupRmonPauseFrameCounterClientInput table " ::= { pmo6006MonupRmonPauseFrameCounterClientInputEntry 1 } pmo6006MonupRmonPauseFrameCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port This counter gives the number of Pause frames received on the client port " ::= { pmo6006MonupRmonPauseFrameCounterClientInputEntry 2 } pmo6006MonupRmonPauseFrameCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port " ::= { pmo6006MonupRmonPauseFrameCounterClientInputEntry 3 } pmo6006MonupRmonPauseFrameCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pause Counter Overload :This OID when set indicates a Pause counter overload on client port " ::= { pmo6006MonupRmonPauseFrameCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MondwRmonCrcErrorsCounterClientInput articles --- ********************************************************* pmo6006MondwRmonCrcErrorsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MondwRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MondwRmonCrcErrorsCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 224 } pmo6006MondwRmonCrcErrorsCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MondwRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table " INDEX { pmo6006MondwRmonCrcErrorsCounterClientInputIndex } ::= { pmo6006MondwRmonCrcErrorsCounterClientInputTable 1 } Pmo6006MondwRmonCrcErrorsCounterClientInputEntry ::= SEQUENCE { pmo6006MondwRmonCrcErrorsCounterClientInputIndex INTEGER, pmo6006MondwRmonCrcErrorsCounterClientInputValuePortn Counter64, pmo6006MondwRmonCrcErrorsCounterClientInputErrorPortn EkiOnOff, pmo6006MondwRmonCrcErrorsCounterClientInputOverloadPortn EkiOnOff } pmo6006MondwRmonCrcErrorsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MondwRmonCrcErrorsCounterClientInput table " ::= { pmo6006MondwRmonCrcErrorsCounterClientInputEntry 1 } pmo6006MondwRmonCrcErrorsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port This counter gives the number of B1/CRC Errors detected on the client port " ::= { pmo6006MondwRmonCrcErrorsCounterClientInputEntry 2 } pmo6006MondwRmonCrcErrorsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port " ::= { pmo6006MondwRmonCrcErrorsCounterClientInputEntry 3 } pmo6006MondwRmonCrcErrorsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port " ::= { pmo6006MondwRmonCrcErrorsCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pmo6006MondwRmonPacketsCounterClientInput articles --- ********************************************************* pmo6006MondwRmonPacketsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MondwRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MondwRmonPacketsCounterClientInput Article " ::= { pmo6006MonClientRmonCounter 240 } pmo6006MondwRmonPacketsCounterClientInputEntry OBJECT-TYPE SYNTAX Pmo6006MondwRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MondwRmonPacketsCounterClientInput table " INDEX { pmo6006MondwRmonPacketsCounterClientInputIndex } ::= { pmo6006MondwRmonPacketsCounterClientInputTable 1 } Pmo6006MondwRmonPacketsCounterClientInputEntry ::= SEQUENCE { pmo6006MondwRmonPacketsCounterClientInputIndex INTEGER, pmo6006MondwRmonPacketsCounterClientInputValuePortn Counter64, pmo6006MondwRmonPacketsCounterClientInputErrorPortn EkiOnOff, pmo6006MondwRmonPacketsCounterClientInputOverloadPortn EkiOnOff } pmo6006MondwRmonPacketsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MondwRmonPacketsCounterClientInput table " ::= { pmo6006MondwRmonPacketsCounterClientInputEntry 1 } pmo6006MondwRmonPacketsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Output Packets :This counter is increased each time a packet is transmitted on the client port. This counter gives the number of packets detected on the client port " ::= { pmo6006MondwRmonPacketsCounterClientInputEntry 2 } pmo6006MondwRmonPacketsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port " ::= { pmo6006MondwRmonPacketsCounterClientInputEntry 3 } pmo6006MondwRmonPacketsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port " ::= { pmo6006MondwRmonPacketsCounterClientInputEntry 4 } pmo6006MonCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "RMON Counters Reset:This OID resets and restarts all the RMON counters" ::= { pmo6006MonRmon 359 } pmo6006MonCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "RMON Counters stop:This OID stops all the RMON counters" ::= { pmo6006MonRmon 360 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pmo6006MesrclientTemp articles --- ********************************************************* pmo6006MesrclientTempTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrclientTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrclientTemp Article " ::= { pmo6006MesrClient 16 } pmo6006MesrclientTempEntry OBJECT-TYPE SYNTAX Pmo6006MesrclientTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrclientTemp table " INDEX { pmo6006MesrclientTempIndex } ::= { pmo6006MesrclientTempTable 1 } Pmo6006MesrclientTempEntry ::= SEQUENCE { pmo6006MesrclientTempIndex INTEGER, pmo6006MesrclientTempPortn INTEGER } pmo6006MesrclientTempIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrclientTemp table " ::= { pmo6006MesrclientTempEntry 1 } pmo6006MesrclientTempPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This Measure gives the Laser temperature value of the Client Transceiver " ::= { pmo6006MesrclientTempEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrclientTxBias articles --- ********************************************************* pmo6006MesrclientTxBiasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrclientTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrclientTxBias Article " ::= { pmo6006MesrClient 32 } pmo6006MesrclientTxBiasEntry OBJECT-TYPE SYNTAX Pmo6006MesrclientTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrclientTxBias table " INDEX { pmo6006MesrclientTxBiasIndex } ::= { pmo6006MesrclientTxBiasTable 1 } Pmo6006MesrclientTxBiasEntry ::= SEQUENCE { pmo6006MesrclientTxBiasIndex INTEGER, pmo6006MesrclientTxBiasPortn INTEGER } pmo6006MesrclientTxBiasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrclientTxBias table " ::= { pmo6006MesrclientTxBiasEntry 1 } pmo6006MesrclientTxBiasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This Measure gives the Laser bias value of the Client Transceiver " ::= { pmo6006MesrclientTxBiasEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrclientTxPwr articles --- ********************************************************* pmo6006MesrclientTxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrclientTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrclientTxPwr Article " ::= { pmo6006MesrClient 48 } pmo6006MesrclientTxPwrEntry OBJECT-TYPE SYNTAX Pmo6006MesrclientTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrclientTxPwr table " INDEX { pmo6006MesrclientTxPwrIndex } ::= { pmo6006MesrclientTxPwrTable 1 } Pmo6006MesrclientTxPwrEntry ::= SEQUENCE { pmo6006MesrclientTxPwrIndex INTEGER, pmo6006MesrclientTxPwrPortn INTEGER } pmo6006MesrclientTxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrclientTxPwr table " ::= { pmo6006MesrclientTxPwrEntry 1 } pmo6006MesrclientTxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the transmit power value of the Client Transceiver " ::= { pmo6006MesrclientTxPwrEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrclientRxPwr articles --- ********************************************************* pmo6006MesrclientRxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrclientRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrclientRxPwr Article " ::= { pmo6006MesrClient 64 } pmo6006MesrclientRxPwrEntry OBJECT-TYPE SYNTAX Pmo6006MesrclientRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrclientRxPwr table " INDEX { pmo6006MesrclientRxPwrIndex } ::= { pmo6006MesrclientRxPwrTable 1 } Pmo6006MesrclientRxPwrEntry ::= SEQUENCE { pmo6006MesrclientRxPwrIndex INTEGER, pmo6006MesrclientRxPwrPortn INTEGER } pmo6006MesrclientRxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrclientRxPwr table " ::= { pmo6006MesrclientRxPwrEntry 1 } pmo6006MesrclientRxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the receive power value of the Client Transceiver " ::= { pmo6006MesrclientRxPwrEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrlineTxPwr articles --- ********************************************************* pmo6006MesrlineTxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrlineTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrlineTxPwr Article " ::= { pmo6006MesrLine 80 } pmo6006MesrlineTxPwrEntry OBJECT-TYPE SYNTAX Pmo6006MesrlineTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrlineTxPwr table " INDEX { pmo6006MesrlineTxPwrIndex } ::= { pmo6006MesrlineTxPwrTable 1 } Pmo6006MesrlineTxPwrEntry ::= SEQUENCE { pmo6006MesrlineTxPwrIndex INTEGER, pmo6006MesrlineTxPwrPortn INTEGER } pmo6006MesrlineTxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrlineTxPwr table " ::= { pmo6006MesrlineTxPwrEntry 1 } pmo6006MesrlineTxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the Tx Laser transmit power value of the Line Transceiver " ::= { pmo6006MesrlineTxPwrEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrlineTemp articles --- ********************************************************* pmo6006MesrlineTempTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrlineTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrlineTemp Article " ::= { pmo6006MesrLine 96 } pmo6006MesrlineTempEntry OBJECT-TYPE SYNTAX Pmo6006MesrlineTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrlineTemp table " INDEX { pmo6006MesrlineTempIndex } ::= { pmo6006MesrlineTempTable 1 } Pmo6006MesrlineTempEntry ::= SEQUENCE { pmo6006MesrlineTempIndex INTEGER, pmo6006MesrlineTempPortn INTEGER } pmo6006MesrlineTempIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrlineTemp table " ::= { pmo6006MesrlineTempEntry 1 } pmo6006MesrlineTempPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This Measure gives the Tx Laser Temperature value of the Line Transceiver " ::= { pmo6006MesrlineTempEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrlineTxBias articles --- ********************************************************* pmo6006MesrlineTxBiasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrlineTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrlineTxBias Article " ::= { pmo6006MesrLine 112 } pmo6006MesrlineTxBiasEntry OBJECT-TYPE SYNTAX Pmo6006MesrlineTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrlineTxBias table " INDEX { pmo6006MesrlineTxBiasIndex } ::= { pmo6006MesrlineTxBiasTable 1 } Pmo6006MesrlineTxBiasEntry ::= SEQUENCE { pmo6006MesrlineTxBiasIndex INTEGER, pmo6006MesrlineTxBiasPortn INTEGER } pmo6006MesrlineTxBiasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrlineTxBias table " ::= { pmo6006MesrlineTxBiasEntry 1 } pmo6006MesrlineTxBiasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This Measure gives the Tx Laser Bias value of the Line Transceiver " ::= { pmo6006MesrlineTxBiasEntry 2 } --- ********************************************************* --- TABLE for the pmo6006MesrlineRxPwr articles --- ********************************************************* pmo6006MesrlineRxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006MesrlineRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pmo6006MesrlineRxPwr Article " ::= { pmo6006MesrLine 128 } pmo6006MesrlineRxPwrEntry OBJECT-TYPE SYNTAX Pmo6006MesrlineRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pmo6006MesrlineRxPwr table " INDEX { pmo6006MesrlineRxPwrIndex } ::= { pmo6006MesrlineRxPwrTable 1 } Pmo6006MesrlineRxPwrEntry ::= SEQUENCE { pmo6006MesrlineRxPwrIndex INTEGER, pmo6006MesrlineRxPwrPortn INTEGER } pmo6006MesrlineRxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pmo6006MesrlineRxPwr table " ::= { pmo6006MesrlineRxPwrEntry 1 } pmo6006MesrlineRxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the Receive power value of the Line Transceiver " ::= { pmo6006MesrlineRxPwrEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- DOWNLOAD --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the restartProcess article --- ***************************************************** pmo6006DwlrestartProcess OBJECT IDENTIFIER ::= { pmo6006DwlOther 0 } pmo6006DwlColdRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Cold Restart :This OID indicates that the module last restart was a Cold RESTART " ::= { pmo6006DwlrestartProcess 2 } pmo6006DwlWarmRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warm Restart :This OID indicates that the module last restart was a Warm RESTART " ::= { pmo6006DwlrestartProcess 1 } --- ***************************************************** --- LEAF for the swBanksUsed article --- ***************************************************** pmo6006DwlswBanksUsed OBJECT IDENTIFIER ::= { pmo6006DwlOther 1 } pmo6006DwlSwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 This status indicates if the SW bank 2 contains SW package " ::= { pmo6006DwlswBanksUsed 6 } pmo6006DwlSwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 This status indicates if the SW bank 1 contains SW package " ::= { pmo6006DwlswBanksUsed 5 } pmo6006DwlSwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 active :This OID indicates the module is working on SW bank 2 This status indicates if the SW bank 2 is active or standby " ::= { pmo6006DwlswBanksUsed 2 } pmo6006DwlSwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 active :This OID indicates the module is working on SW bank 1 This status indicates if the SW bank 1 is active or standby " ::= { pmo6006DwlswBanksUsed 1 } --- ***************************************************** --- LEAF for the gwBanksUsed article --- ***************************************************** pmo6006DwlgwBanksUsed OBJECT IDENTIFIER ::= { pmo6006DwlOther 2 } pmo6006DwlGwBank4Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 " ::= { pmo6006DwlgwBanksUsed 8 } pmo6006DwlGwBank3Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 This status indicates if the GW bank 3 contains GW package " ::= { pmo6006DwlgwBanksUsed 7 } pmo6006DwlGwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 " ::= { pmo6006DwlgwBanksUsed 6 } pmo6006DwlGwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 This status indicates if the GW bank 1 contains GW package " ::= { pmo6006DwlgwBanksUsed 5 } pmo6006DwlGwBank4Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 active :This OID indicates the module is working on GW bank 4 " ::= { pmo6006DwlgwBanksUsed 4 } pmo6006DwlGwBank3Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 active :This OID indicates the module is working on GW bank 3 This status indicates if the GW bank 3 is active or standby " ::= { pmo6006DwlgwBanksUsed 3 } pmo6006DwlGwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 active :This OID indicates the module is working on GW bank 2 " ::= { pmo6006DwlgwBanksUsed 2 } pmo6006DwlGwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 active :This OID indicates the module is working on GW bank 1 This status indicates if the GW bank 1 is active or standby " ::= { pmo6006DwlgwBanksUsed 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group startup --- ***************************************************** pmo6006CfgStartup OBJECT IDENTIFIER ::= { pmo6006Config 1 } --- ***************************************************** --- LEAF for the table 2110 --- ***************************************************** pmo6006CfgClientStartupTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientStartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgStartup 1 } pmo6006CfgClientStartupEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientStartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pmo6006CfgClientStartupIndex } ::= { pmo6006CfgClientStartupTable 1 } Pmo6006CfgClientStartupEntry ::= SEQUENCE { pmo6006CfgClientStartupIndex INTEGER, pmo6006CfgSystConfPortPortn Unsigned32, pmo6006CfgNetConfPortPortn Unsigned32, pmo6006CfgOptionsPortPortn Unsigned32 } pmo6006CfgClientStartupIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientStartup table " ::= { pmo6006CfgClientStartupEntry 1 } pmo6006CfgSystConfPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Port :This register configures the default initialisation settings on the port. " ::= { pmo6006CfgClientStartupEntry 3 } pmo6006CfgNetConfPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Port :This register configures the default initialisation settings on the port. " ::= { pmo6006CfgClientStartupEntry 4 } pmo6006CfgOptionsPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Client Port :This register configures the default options on the port. " ::= { pmo6006CfgClientStartupEntry 14 } --- ***************************************************** --- LEAF for the table 2190 --- ***************************************************** pmo6006CfgLinexr1StartupTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLinexr1StartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgStartup 2 } pmo6006CfgLinexr1StartupEntry OBJECT-TYPE SYNTAX Pmo6006CfgLinexr1StartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pmo6006CfgLinexr1StartupIndex } ::= { pmo6006CfgLinexr1StartupTable 1 } Pmo6006CfgLinexr1StartupEntry ::= SEQUENCE { pmo6006CfgLinexr1StartupIndex INTEGER, pmo6006CfgSystConfLinePortn Unsigned32, pmo6006CfgOptionsLinePortn Unsigned32 } pmo6006CfgLinexr1StartupIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the linexr1Startup table " ::= { pmo6006CfgLinexr1StartupEntry 1 } pmo6006CfgSystConfLinePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line :This register configures the default initialisation settings on Line " ::= { pmo6006CfgLinexr1StartupEntry 3 } pmo6006CfgOptionsLinePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Line :This register configures the default options on the line " ::= { pmo6006CfgLinexr1StartupEntry 14 } --- ***************************************************** --- LEAF for the table 2710 --- ***************************************************** pmo6006CfgOtxtlhTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgStartup 3 } pmo6006CfgOtxtlhEntry OBJECT-TYPE SYNTAX Pmo6006CfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pmo6006CfgOtxtlhIndex } ::= { pmo6006CfgOtxtlhTable 1 } Pmo6006CfgOtxtlhEntry ::= SEQUENCE { pmo6006CfgOtxtlhIndex INTEGER, pmo6006CfgLineControlsPortn Unsigned32, pmo6006CfgLinePwrLaserPortn Unsigned32, pmo6006CfgLineFCurrentPortn Unsigned32, pmo6006CfgLineGridCurrentPortn Unsigned32, pmo6006CfgLineFoPortn Unsigned32 } pmo6006CfgOtxtlhIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlh table " ::= { pmo6006CfgOtxtlhEntry 1 } pmo6006CfgLineControlsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Default Line settings :This register configures the start-up settings on the ports " ::= { pmo6006CfgOtxtlhEntry 3 } pmo6006CfgLinePwrLaserPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm) " ::= { pmo6006CfgOtxtlhEntry 6 } pmo6006CfgLineFCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line transceiver Channel :This register configures the start-up laser channel of the client transceiver " ::= { pmo6006CfgOtxtlhEntry 7 } pmo6006CfgLineGridCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line transceiver Grid :This register configures the start-up laser grid of the client transceiver " ::= { pmo6006CfgOtxtlhEntry 8 } pmo6006CfgLineFoPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line first Frequency :This register configures the start-up first frequency of the client transceiver " ::= { pmo6006CfgOtxtlhEntry 9 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmo6006CfgLabels OBJECT IDENTIFIER ::= { pmo6006Config 2 } --- ***************************************************** --- LEAF for the table 0003 --- ***************************************************** pmo6006CfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgLabels 1 } pmo6006CfgLabelclientEntry OBJECT-TYPE SYNTAX Pmo6006CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmo6006CfgLabelclientIndex } ::= { pmo6006CfgLabelclientTable 1 } Pmo6006CfgLabelclientEntry ::= SEQUENCE { pmo6006CfgLabelclientIndex INTEGER, pmo6006CfgLabelclientPortn DisplayString } pmo6006CfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmo6006CfgLabelclientEntry 1 } pmo6006CfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmo6006CfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table 0004 --- ***************************************************** pmo6006CfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgLabels 2 } pmo6006CfgLabellineEntry OBJECT-TYPE SYNTAX Pmo6006CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmo6006CfgLabellineIndex } ::= { pmo6006CfgLabellineTable 1 } Pmo6006CfgLabellineEntry ::= SEQUENCE { pmo6006CfgLabellineIndex INTEGER, pmo6006CfgLabellinePortn DisplayString } pmo6006CfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmo6006CfgLabellineEntry 1 } pmo6006CfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmo6006CfgLabellineEntry 3 } --- ***************************************************** --- LEAF for the table Group other --- ***************************************************** pmo6006CfgOther OBJECT IDENTIFIER ::= { pmo6006Config 3 } --- ***************************************************** --- LEAF for the table 2300 --- ***************************************************** pmo6006tablemoduleOther OBJECT IDENTIFIER ::= { pmo6006CfgOther 1 } pmo6006Cfgmode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on Module :This register selects the configuration mode of the module " ::= { pmo6006tablemoduleOther 2 } --- ***************************************************** --- LEAF for the table Group odu2Clienta --- ***************************************************** pmo6006CfgOdu2Clienta OBJECT IDENTIFIER ::= { pmo6006Config 4 } --- ***************************************************** --- LEAF for the table 29C0 --- ***************************************************** pmo6006CfgClientStartupOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientStartupOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgOdu2Clienta 1 } pmo6006CfgClientStartupOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientStartupOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the odu2Clienta table " INDEX { pmo6006CfgClientStartupOduIndex } ::= { pmo6006CfgClientStartupOduTable 1 } Pmo6006CfgClientStartupOduEntry ::= SEQUENCE { pmo6006CfgClientStartupOduIndex INTEGER, pmo6006CfgOdu2ReserveLsbPortn Unsigned32, pmo6006CfgOdu2DegthresholdPortn Unsigned32, pmo6006CfgOdu2DegmPortn Unsigned32, pmo6006CfgOdu2SettingsPortn Unsigned32 } pmo6006CfgClientStartupOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientStartupOdu table " ::= { pmo6006CfgClientStartupOduEntry 1 } pmo6006CfgOdu2ReserveLsbPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " : " ::= { pmo6006CfgClientStartupOduEntry 3 } pmo6006CfgOdu2DegthresholdPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Degrade Threshold : " ::= { pmo6006CfgClientStartupOduEntry 4 } pmo6006CfgOdu2DegmPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Degrade Confirmation : " ::= { pmo6006CfgClientStartupOduEntry 5 } pmo6006CfgOdu2SettingsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Settings : " ::= { pmo6006CfgClientStartupOduEntry 6 } --- ***************************************************** --- LEAF for the table Group otu2Line --- ***************************************************** pmo6006CfgOtu2Line OBJECT IDENTIFIER ::= { pmo6006Config 5 } --- ***************************************************** --- LEAF for the table 29E0 --- ***************************************************** pmo6006CfgLinexStartupOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLinexStartupOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgOtu2Line 1 } pmo6006CfgLinexStartupOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLinexStartupOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the otu2Line table " INDEX { pmo6006CfgLinexStartupOtuIndex } ::= { pmo6006CfgLinexStartupOtuTable 1 } Pmo6006CfgLinexStartupOtuEntry ::= SEQUENCE { pmo6006CfgLinexStartupOtuIndex INTEGER, pmo6006CfgOtu2ReserveMsbPortn Unsigned32, pmo6006CfgOtu2DegthresholdPortn Unsigned32, pmo6006CfgOtu2DegmPortn Unsigned32, pmo6006CfgOtu2SettingsPortn Unsigned32 } pmo6006CfgLinexStartupOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the linexStartupOtu table " ::= { pmo6006CfgLinexStartupOtuEntry 1 } pmo6006CfgOtu2ReserveMsbPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " : " ::= { pmo6006CfgLinexStartupOtuEntry 3 } pmo6006CfgOtu2DegthresholdPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Degrade Threshold : " ::= { pmo6006CfgLinexStartupOtuEntry 4 } pmo6006CfgOtu2DegmPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Degrade Confirmation : " ::= { pmo6006CfgLinexStartupOtuEntry 5 } pmo6006CfgOtu2SettingsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Settings : " ::= { pmo6006CfgLinexStartupOtuEntry 6 } --- ***************************************************** --- LEAF for the table Group sapiTxClient --- ***************************************************** pmo6006CfgSapiTxClient OBJECT IDENTIFIER ::= { pmo6006Config 6 } --- ***************************************************** --- LEAF for the table 2A10 --- ***************************************************** pmo6006CfgClientSapiTxOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientSapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiTxClient 1 } pmo6006CfgClientSapiTxOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientSapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiTxClient table " INDEX { pmo6006CfgClientSapiTxOduIndex } ::= { pmo6006CfgClientSapiTxOduTable 1 } Pmo6006CfgClientSapiTxOduEntry ::= SEQUENCE { pmo6006CfgClientSapiTxOduIndex INTEGER, pmo6006CfgClientSapiTxSetupPortn DisplayString } pmo6006CfgClientSapiTxOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiTxOdu table " ::= { pmo6006CfgClientSapiTxOduEntry 1 } pmo6006CfgClientSapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pmo6006CfgClientSapiTxOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiExpClient --- ***************************************************** pmo6006CfgSapiExpClient OBJECT IDENTIFIER ::= { pmo6006Config 7 } --- ***************************************************** --- LEAF for the table 2A30 --- ***************************************************** pmo6006CfgClientSapiExpOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientSapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiExpClient 1 } pmo6006CfgClientSapiExpOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientSapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiExpClient table " INDEX { pmo6006CfgClientSapiExpOduIndex } ::= { pmo6006CfgClientSapiExpOduTable 1 } Pmo6006CfgClientSapiExpOduEntry ::= SEQUENCE { pmo6006CfgClientSapiExpOduIndex INTEGER, pmo6006CfgClientSapiExpSetupPortn DisplayString } pmo6006CfgClientSapiExpOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiExpOdu table " ::= { pmo6006CfgClientSapiExpOduEntry 1 } pmo6006CfgClientSapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Expected SAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pmo6006CfgClientSapiExpOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiAccClient --- ***************************************************** pmo6006CfgSapiAccClient OBJECT IDENTIFIER ::= { pmo6006Config 8 } --- ***************************************************** --- LEAF for the table 2A50 --- ***************************************************** pmo6006CfgClientSapiAccOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientSapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiAccClient 1 } pmo6006CfgClientSapiAccOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientSapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiAccClient table " INDEX { pmo6006CfgClientSapiAccOduIndex } ::= { pmo6006CfgClientSapiAccOduTable 1 } Pmo6006CfgClientSapiAccOduEntry ::= SEQUENCE { pmo6006CfgClientSapiAccOduIndex INTEGER, pmo6006CfgClientSapiAccSetupPortn DisplayString } pmo6006CfgClientSapiAccOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiAccOdu table " ::= { pmo6006CfgClientSapiAccOduEntry 1 } pmo6006CfgClientSapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Client Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pmo6006CfgClientSapiAccOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiTxClient --- ***************************************************** pmo6006CfgDapiTxClient OBJECT IDENTIFIER ::= { pmo6006Config 9 } --- ***************************************************** --- LEAF for the table 2A90 --- ***************************************************** pmo6006CfgClientDapiTxOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientDapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiTxClient 1 } pmo6006CfgClientDapiTxOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientDapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiTxClient table " INDEX { pmo6006CfgClientDapiTxOduIndex } ::= { pmo6006CfgClientDapiTxOduTable 1 } Pmo6006CfgClientDapiTxOduEntry ::= SEQUENCE { pmo6006CfgClientDapiTxOduIndex INTEGER, pmo6006CfgClientDapiTxSetupPortn DisplayString } pmo6006CfgClientDapiTxOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiTxOdu table " ::= { pmo6006CfgClientDapiTxOduEntry 1 } pmo6006CfgClientDapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pmo6006CfgClientDapiTxOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiExpClient --- ***************************************************** pmo6006CfgDapiExpClient OBJECT IDENTIFIER ::= { pmo6006Config 10 } --- ***************************************************** --- LEAF for the table 2AB0 --- ***************************************************** pmo6006CfgClientDapiExpOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientDapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiExpClient 1 } pmo6006CfgClientDapiExpOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientDapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiExpClient table " INDEX { pmo6006CfgClientDapiExpOduIndex } ::= { pmo6006CfgClientDapiExpOduTable 1 } Pmo6006CfgClientDapiExpOduEntry ::= SEQUENCE { pmo6006CfgClientDapiExpOduIndex INTEGER, pmo6006CfgClientDapiExpSetupPortn DisplayString } pmo6006CfgClientDapiExpOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiExpOdu table " ::= { pmo6006CfgClientDapiExpOduEntry 1 } pmo6006CfgClientDapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Expected DAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pmo6006CfgClientDapiExpOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiAccClient --- ***************************************************** pmo6006CfgDapiAccClient OBJECT IDENTIFIER ::= { pmo6006Config 11 } --- ***************************************************** --- LEAF for the table 2AD0 --- ***************************************************** pmo6006CfgClientDapiAccOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgClientDapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiAccClient 1 } pmo6006CfgClientDapiAccOduEntry OBJECT-TYPE SYNTAX Pmo6006CfgClientDapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiAccClient table " INDEX { pmo6006CfgClientDapiAccOduIndex } ::= { pmo6006CfgClientDapiAccOduTable 1 } Pmo6006CfgClientDapiAccOduEntry ::= SEQUENCE { pmo6006CfgClientDapiAccOduIndex INTEGER, pmo6006CfgClientDapiAccSetupPortn DisplayString } pmo6006CfgClientDapiAccOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiAccOdu table " ::= { pmo6006CfgClientDapiAccOduEntry 1 } pmo6006CfgClientDapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Client Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pmo6006CfgClientDapiAccOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiTxLine --- ***************************************************** pmo6006CfgSapiTxLine OBJECT IDENTIFIER ::= { pmo6006Config 12 } --- ***************************************************** --- LEAF for the table 2B10 --- ***************************************************** pmo6006CfgLineSapiTxOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineSapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiTxLine 1 } pmo6006CfgLineSapiTxOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineSapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiTxLine table " INDEX { pmo6006CfgLineSapiTxOtuIndex } ::= { pmo6006CfgLineSapiTxOtuTable 1 } Pmo6006CfgLineSapiTxOtuEntry ::= SEQUENCE { pmo6006CfgLineSapiTxOtuIndex INTEGER, pmo6006CfgLineSapiTxSetupPortn DisplayString } pmo6006CfgLineSapiTxOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiTxOtu table " ::= { pmo6006CfgLineSapiTxOtuEntry 1 } pmo6006CfgLineSapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pmo6006CfgLineSapiTxOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiExpLine --- ***************************************************** pmo6006CfgSapiExpLine OBJECT IDENTIFIER ::= { pmo6006Config 13 } --- ***************************************************** --- LEAF for the table 2B30 --- ***************************************************** pmo6006CfgLineSapiExpOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineSapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiExpLine 1 } pmo6006CfgLineSapiExpOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineSapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiExpLine table " INDEX { pmo6006CfgLineSapiExpOtuIndex } ::= { pmo6006CfgLineSapiExpOtuTable 1 } Pmo6006CfgLineSapiExpOtuEntry ::= SEQUENCE { pmo6006CfgLineSapiExpOtuIndex INTEGER, pmo6006CfgLineSapiExpSetupPortn DisplayString } pmo6006CfgLineSapiExpOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiExpOtu table " ::= { pmo6006CfgLineSapiExpOtuEntry 1 } pmo6006CfgLineSapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pmo6006CfgLineSapiExpOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiAccLine --- ***************************************************** pmo6006CfgSapiAccLine OBJECT IDENTIFIER ::= { pmo6006Config 14 } --- ***************************************************** --- LEAF for the table 2B50 --- ***************************************************** pmo6006CfgLineSapiAccOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineSapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgSapiAccLine 1 } pmo6006CfgLineSapiAccOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineSapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiAccLine table " INDEX { pmo6006CfgLineSapiAccOtuIndex } ::= { pmo6006CfgLineSapiAccOtuTable 1 } Pmo6006CfgLineSapiAccOtuEntry ::= SEQUENCE { pmo6006CfgLineSapiAccOtuIndex INTEGER, pmo6006CfgLineSapiAccSetupPortn DisplayString } pmo6006CfgLineSapiAccOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiAccOtu table " ::= { pmo6006CfgLineSapiAccOtuEntry 1 } pmo6006CfgLineSapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pmo6006CfgLineSapiAccOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiTxLine --- ***************************************************** pmo6006CfgDapiTxLine OBJECT IDENTIFIER ::= { pmo6006Config 15 } --- ***************************************************** --- LEAF for the table 2B90 --- ***************************************************** pmo6006CfgLineDapiTxOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineDapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiTxLine 1 } pmo6006CfgLineDapiTxOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineDapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiTxLine table " INDEX { pmo6006CfgLineDapiTxOtuIndex } ::= { pmo6006CfgLineDapiTxOtuTable 1 } Pmo6006CfgLineDapiTxOtuEntry ::= SEQUENCE { pmo6006CfgLineDapiTxOtuIndex INTEGER, pmo6006CfgLineDapiTxSetupPortn DisplayString } pmo6006CfgLineDapiTxOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiTxOtu table " ::= { pmo6006CfgLineDapiTxOtuEntry 1 } pmo6006CfgLineDapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pmo6006CfgLineDapiTxOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiExpLine --- ***************************************************** pmo6006CfgDapiExpLine OBJECT IDENTIFIER ::= { pmo6006Config 16 } --- ***************************************************** --- LEAF for the table 2BB0 --- ***************************************************** pmo6006CfgLineDapiExpOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineDapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiExpLine 1 } pmo6006CfgLineDapiExpOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineDapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiExpLine table " INDEX { pmo6006CfgLineDapiExpOtuIndex } ::= { pmo6006CfgLineDapiExpOtuTable 1 } Pmo6006CfgLineDapiExpOtuEntry ::= SEQUENCE { pmo6006CfgLineDapiExpOtuIndex INTEGER, pmo6006CfgLineDapiExpSetupPortn DisplayString } pmo6006CfgLineDapiExpOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiExpOtu table " ::= { pmo6006CfgLineDapiExpOtuEntry 1 } pmo6006CfgLineDapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pmo6006CfgLineDapiExpOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiAccLine --- ***************************************************** pmo6006CfgDapiAccLine OBJECT IDENTIFIER ::= { pmo6006Config 17 } --- ***************************************************** --- LEAF for the table 2BD0 --- ***************************************************** pmo6006CfgLineDapiAccOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgLineDapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgDapiAccLine 1 } pmo6006CfgLineDapiAccOtuEntry OBJECT-TYPE SYNTAX Pmo6006CfgLineDapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiAccLine table " INDEX { pmo6006CfgLineDapiAccOtuIndex } ::= { pmo6006CfgLineDapiAccOtuTable 1 } Pmo6006CfgLineDapiAccOtuEntry ::= SEQUENCE { pmo6006CfgLineDapiAccOtuIndex INTEGER, pmo6006CfgLineDapiAccSetupPortn DisplayString } pmo6006CfgLineDapiAccOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiAccOtu table " ::= { pmo6006CfgLineDapiAccOtuEntry 1 } pmo6006CfgLineDapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pmo6006CfgLineDapiAccOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group startuptablefive --- ***************************************************** pmo6006CfgStartuptablefive OBJECT IDENTIFIER ::= { pmo6006Config 18 } --- ***************************************************** --- LEAF for the table 0005 --- ***************************************************** pmo6006CfgOtxtlhcapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmo6006CfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmo6006CfgStartuptablefive 1 } pmo6006CfgOtxtlhcapabilitiesEntry OBJECT-TYPE SYNTAX Pmo6006CfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startuptablefive table " INDEX { pmo6006CfgOtxtlhcapabilitiesIndex } ::= { pmo6006CfgOtxtlhcapabilitiesTable 1 } Pmo6006CfgOtxtlhcapabilitiesEntry ::= SEQUENCE { pmo6006CfgOtxtlhcapabilitiesIndex INTEGER, pmo6006CfgComponentTypePortn Unsigned32, pmo6006CfgMiscellaneousPortn Unsigned32, pmo6006CfgFirstChannelPortn Unsigned32, pmo6006CfgLastChannelPortn Unsigned32, pmo6006CfgGridPortn Unsigned32 } pmo6006CfgOtxtlhcapabilitiesIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlhcapabilities table " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 1 } pmo6006CfgComponentTypePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Component parameters :This OID defines the component parameters " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 3 } pmo6006CfgMiscellaneousPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Miscellaneous default settings :This OID defines the miscellaneous parameters " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 4 } pmo6006CfgFirstChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the first channel of the component :This OID defines the first channel number of the PM " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 5 } pmo6006CfgLastChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the last channel of the component :This OID defines the last channel number of the PM " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 6 } pmo6006CfgGridPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Grid value of the component :This OID defines the grid of the PM " ::= { pmo6006CfgOtxtlhcapabilitiesEntry 7 } pmo6006CfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmo6006Config 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmo6006trapPortNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last port which generates a trap" ::= { pmo6006traps 2 } pmo6006trapLineNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last Line which generates a trap" ::= { pmo6006traps 3 } pmo6006trapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmo6006traps 4 } --- ***************************************************** --- LINE TRAPS --- ***************************************************** pmo6006LineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineDdmWarningPortn, pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmo6006AlmLineDdmWarningPortn "on", pmo6006trapLineNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Warning appears on Line Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pmo6006traps 30 } pmo6006LineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineDdmWarningPortn, pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Line Not Urgent ON" } --&MATCH { pmo6006AlmLineDdmWarningPortn "on", pmo6006trapLineNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Warning disappears on Line Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pmo6006traps 31 } pmo6006LineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineDdmAlmPortn, pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pmo6006AlmLineDdmAlmPortn "on", pmo6006trapLineNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Alarm appears on Line Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pmo6006traps 32 } pmo6006LineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineDdmAlmPortn, pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Line Urgent ON" } --&MATCH { pmo6006AlmLineDdmAlmPortn "on", pmo6006trapLineNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Alarm disappears on Line Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pmo6006traps 33 } pmo6006LineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineFailPortn , pmo6006AlmLineHwFailPortn , pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pmo6006AlmLineFailPortn "on", pmo6006AlmLineHwFailPortn "*", pmo6006trapLineNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Line Port $3 Down on PMO6006 in Slot $4 ($A)" --&FILTNAME "PMO6006 Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmo6006AlmLineFailPortn "*", pmo6006AlmLineHwFailPortn "on", pmo6006trapLineNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Line Port $3 Down on PMO6006 in Slot $4 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmo6006traps 34 } pmo6006LineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmLineFailPortn , pmo6006AlmLineHwFailPortn , pmo6006trapLineNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Line Fail ON" } --&MATCH { pmo6006AlmLineFailPortn "on", pmo6006AlmLineHwFailPortn "*", pmo6006trapLineNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Line Port $3 Up on PMO6006 in Slot $4 ($A)" --&FILTNAME "PMO6006 Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmo6006AlmLineFailPortn "*", pmo6006AlmLineHwFailPortn "on", pmo6006trapLineNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Line Port $3 Up on PMO6006 in Slot $4 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmo6006traps 35 } --- ***************************************************** --- CLIENT TRAPS --- ***************************************************** pmo6006ClientTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmSfpDdmWarningPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmo6006AlmSfpDdmWarningPortn "on", pmo6006trapPortNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Warning appears on Client Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pmo6006traps 40 } pmo6006ClientTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmSfpDdmWarningPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Client Not Urgent ON" } --&MATCH { pmo6006AlmSfpDdmWarningPortn "on", pmo6006trapPortNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Warning appears on Client Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pmo6006traps 41 } pmo6006ClientTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmSfpDdmAlmPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Urgent ON" --&ACTIONS { log, major } --&MATCH { pmo6006AlmSfpDdmAlmPortn "on", pmo6006trapPortNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Alarm appears on Client Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pmo6006traps 42 } pmo6006ClientTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmSfpDdmAlmPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Client Urgent ON" } --&MATCH { pmo6006AlmSfpDdmAlmPortn "on", pmo6006trapPortNumber "$2", pmo6006trapBoardNumber "$3"} --&MESG "DDM Alarm disappears on Client Port $2 of PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pmo6006traps 43 } pmo6006ClientTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmFailAccPortn, pmo6006AlmHwFailAccPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Fail ON" --&ACTIONS { log, critical } --&MATCH { pmo6006AlmFailAccPortn "on", pmo6006AlmHwFailAccPortn "*", pmo6006trapPortNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Client Port $3 Down on PMO6006 in Slot $4 ($A)" --&FILTNAME "PMO6006 Client HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmo6006AlmFailAccPortn "*", pmo6006AlmHwFailAccPortn "on", pmo6006trapPortNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Client Port $3 Down on PMO6006 in Slot $4 ($A)" DESCRIPTION "Critical client default is activated" ::= { pmo6006traps 44 } pmo6006ClientTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmFailAccPortn, pmo6006AlmHwFailAccPortn, pmo6006trapPortNumber, pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Client Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PMO6006 Client Fail ON" } --&MATCH { pmo6006AlmFailAccPortn "on", pmo6006AlmHwFailAccPortn "*", pmo6006trapPortNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Client Port $3 Up on PMO6006 in Slot $4 ($A)" --&FILTNAME "PMO6006 Client HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmo6006AlmFailAccPortn "*", pmo6006AlmHwFailAccPortn "on", pmo6006trapPortNumber "$3", pmo6006trapBoardNumber "$4"} --&MESG "Client Port $3 Up on PMO6006 in Slot $4 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pmo6006traps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmo6006PowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmo6006AlmDefFuseB, pmo6006AlmDefFuseA , pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmo6006AlmDefFuseB "*", pmo6006AlmDefFuseA "on", pmo6006trapBoardNumber "$3"} --&MESG "Power Input A Fail on PMO6006 in Slot $3 ($A)" --&FILTNAME "PMO6006 Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmo6006AlmDefFuseB "on", pmo6006AlmDefFuseA "*", pmo6006trapBoardNumber "$3"} --&MESG "Power Input B Fail on PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmo6006traps 50 } pmo6006PowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmo6006AlmDefFuseB, pmo6006AlmDefFuseA , pmo6006trapBoardNumber} STATUS current --&FILTNAME "PMO6006 Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMO6006 Fuse A Fail ON", "PMO6006 Fuse B Fail ON" } --&MATCH { pmo6006AlmDefFuseB "on", pmo6006AlmDefFuseA "on", pmo6006trapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMO6006 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmo6006traps 51 } END