-- ***************************************************************** -- EKINOPS-Pme1008.TXT: MIB -- --MIB Part Number:3MI00041AAAA --MIB Version:03 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pme1008-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePme1008 MODULE-IDENTITY LAST-UPDATED "201609050000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.fr" DESCRIPTION "Creation." REVISION "201609050000Z" DESCRIPTION "Creation for PME1008" ::= { ekinops 79 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pme1008alarms OBJECT IDENTIFIER ::= { modulePme1008 2 } pme1008AlmOther OBJECT IDENTIFIER ::= { pme1008alarms 1 } pme1008AlmOtherNurg OBJECT IDENTIFIER ::= { pme1008AlmOther 1 } pme1008AlmOtherUrg OBJECT IDENTIFIER ::= { pme1008AlmOther 2 } pme1008AlmOtherCrit OBJECT IDENTIFIER ::= { pme1008AlmOther 3 } pme1008AlmClient OBJECT IDENTIFIER ::= { pme1008alarms 2 } pme1008AlmClientNurg OBJECT IDENTIFIER ::= { pme1008AlmClient 1 } pme1008AlmClientUrg OBJECT IDENTIFIER ::= { pme1008AlmClient 2 } pme1008AlmClientCrit OBJECT IDENTIFIER ::= { pme1008AlmClient 3 } pme1008AlmLine OBJECT IDENTIFIER ::= { pme1008alarms 3 } pme1008AlmLineNurg OBJECT IDENTIFIER ::= { pme1008AlmLine 1 } pme1008AlmLineUrg OBJECT IDENTIFIER ::= { pme1008AlmLine 2 } pme1008AlmLineCrit OBJECT IDENTIFIER ::= { pme1008AlmLine 3 } pme1008measures OBJECT IDENTIFIER ::= { modulePme1008 3 } pme1008MesrOther OBJECT IDENTIFIER ::= { pme1008measures 1 } pme1008MesrClient OBJECT IDENTIFIER ::= { pme1008measures 2 } pme1008MesrLine OBJECT IDENTIFIER ::= { pme1008measures 3 } pme1008counters OBJECT IDENTIFIER ::= { modulePme1008 4 } pme1008CntOther OBJECT IDENTIFIER ::= { pme1008counters 1 } pme1008CntClient OBJECT IDENTIFIER ::= { pme1008counters 2 } pme1008CntLine OBJECT IDENTIFIER ::= { pme1008counters 3 } pme1008controlsWrite OBJECT IDENTIFIER ::= { modulePme1008 6 } pme1008CtrlOther OBJECT IDENTIFIER ::= { pme1008controlsWrite 1 } pme1008CtrlClient OBJECT IDENTIFIER ::= { pme1008controlsWrite 2 } pme1008CtrlLine OBJECT IDENTIFIER ::= { pme1008controlsWrite 3 } pme1008ri OBJECT IDENTIFIER ::= { modulePme1008 7 } pme1008riTable OBJECT IDENTIFIER ::= { pme1008ri 1 } pme1008download OBJECT IDENTIFIER ::= { modulePme1008 8 } pme1008DwlOther OBJECT IDENTIFIER ::= { pme1008download 1 } pme1008DwlClient OBJECT IDENTIFIER ::= { pme1008download 2 } pme1008DwlLine OBJECT IDENTIFIER ::= { pme1008download 3 } pme1008Config OBJECT IDENTIFIER ::= { modulePme1008 9 } pme1008traps OBJECT IDENTIFIER ::= { modulePme1008 10 } pme1008Monitoring OBJECT IDENTIFIER ::= { modulePme1008 11} pme1008MonOther OBJECT IDENTIFIER ::= { pme1008Monitoring 1 } pme1008MonRmon OBJECT IDENTIFIER ::= { pme1008MonOther 3 } pme1008MonClient OBJECT IDENTIFIER ::= { pme1008Monitoring 2 } pme1008MonClientRmonCounter OBJECT IDENTIFIER ::= { pme1008MonClient 4 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** Pme1008OtxGrid ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different grids on client and line ports" SYNTAX INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } Pme1008DccMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for DCC" SYNTAX INTEGER { dccNo(0), dccLine1(1), dccLine2(2) } Pme1008LineChannel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Channel selection on transceiver Line ports" SYNTAX INTEGER Pme1008Odu2SapiMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for SAPI-DAPI" SYNTAX INTEGER { off(0), sapi(1), dapi(2), sapidapi(3) } Pme1008Otu2SapiMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Mode for SAPI-DAPI" SYNTAX INTEGER { off(0), sapi(1), dapi(2), sapidapi(3) } Pme1008ClientProtocol ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different values on the protocol on the client ports" SYNTAX INTEGER { protocolclientvalue2(2), protocolclientvalue3(3), protocolclientvalue4(4), protocolclientvalue6(6), protocolclientvalue7(7) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pme1008RinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pme1008ri 2 } pme1008RinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pme1008ri 3 } pme1008RinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pme1008ri 4 } pme1008RinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pme1008ri 5 } pme1008RinvGwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "GW platform description: This OID contains the description of the Gateware platform." ::= { pme1008ri 6 } pme1008RinvSfpTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008RinvSfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the SFPs on the selected module" ::= { pme1008riTable 1 } pme1008RinvSfpEntry OBJECT-TYPE SYNTAX Pme1008RinvSfpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the SFP table" INDEX { pme1008RinvSfpIndex } ::= { pme1008RinvSfpTable 1 } Pme1008RinvSfpEntry::= SEQUENCE { pme1008RinvSfpIndex Integer32, pme1008Rinvsfp DisplayString } pme1008RinvSfpIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for SFP table" ::= { pme1008RinvSfpEntry 1 } pme1008Rinvsfp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the SFP: This OID contains the inventory for the SFP" ::= { pme1008RinvSfpEntry 2 } pme1008RinvLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the SFPs on the selected module" ::= { pme1008riTable 2 } pme1008RinvLineEntry OBJECT-TYPE SYNTAX Pme1008RinvLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the SFP table" INDEX { pme1008RinvLineIndex } ::= { pme1008RinvLineTable 1 } Pme1008RinvLineEntry::= SEQUENCE { pme1008RinvLineIndex Integer32, pme1008RinvxfpLine DisplayString } pme1008RinvLineIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for SFP table" ::= { pme1008RinvLineEntry 1 } pme1008RinvxfpLine OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the XFP: This OID contains the inventory for the XFP" ::= { pme1008RinvLineEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pme1008AlmsynthAlm0 OBJECT IDENTIFIER ::= { pme1008AlmOtherCrit 0 } pme1008AlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmsynthAlm0 16 } pme1008AlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmsynthAlm0 15 } pme1008AlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the RM This alarm is set on detection of a failure originating from the equipment MOD_GLOB_FAIL other (1) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pme1008AlmsynthAlm2 OBJECT IDENTIFIER ::= { pme1008AlmOtherNurg 2 } pme1008AlmCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This OID, when set, indicates that alarm correlation is not being performed. CORRELAT_OFF informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlm2 4 } pme1008AlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlm2 3 } pme1008AlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlm2 2 } pme1008AlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlm2 1 } --- ********************************************************* --- TABLE for the pme1008AlmsynthAlmPort articles --- ********************************************************* pme1008AlmsynthAlmPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmsynthAlmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmsynthAlmPort Article " ::= { pme1008AlmClientCrit 8 } pme1008AlmsynthAlmPortEntry OBJECT-TYPE SYNTAX Pme1008AlmsynthAlmPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmsynthAlmPort table " INDEX { pme1008AlmsynthAlmPortIndex } ::= { pme1008AlmsynthAlmPortTable 1 } Pme1008AlmsynthAlmPortEntry ::= SEQUENCE { pme1008AlmsynthAlmPortIndex INTEGER, pme1008AlmUpCsfPortn EkiOnOff, pme1008AlmFailAccPortn EkiOnOff, pme1008AlmSfpDdmAlmPortn EkiOnOff, pme1008AlmSfpDdmWarningPortn EkiOnOff, pme1008AlmDwCaisPortn EkiOnOff, pme1008AlmClientRemoteOosPortn EkiOnOff, pme1008AlmClientLocalOosPortn EkiOnOff, pme1008AlmDwLsdPortn EkiOnOff, pme1008AlmHwFailAccPortn EkiOnOff, pme1008AlmDdmAbsentPortn EkiOnOff, pme1008AlmSfpAbsentPortn EkiOnOff } pme1008AlmsynthAlmPortIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmsynthAlmPort table " ::= { pme1008AlmsynthAlmPortEntry 1 } pme1008AlmUpCsfPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Signal Fail Inserted :This OID indicates a CSF has been inserted in the upstream client port. This status indicates if a Client Signal Fail is currently inserted on the line signal for this client port UP_CSF_1 informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmPortEntry 17 } pme1008AlmFailAccPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Access Fail :This OID indicates a failure on the Client port This alarm indicates a failure on the Client port FAIL_ACC_1 equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmPortEntry 13 } pme1008AlmSfpDdmAlmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Client Trscv DDM :This OID indicates an alarm is being received from the Client Transceiver DDM This alarm indicates if a DDM Alarm has been detected on the client transceiver SFP_DDM_ALM_1 inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmPortEntry 11 } pme1008AlmSfpDdmWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM This alarm indicates if a DDM Warning has been detected on the client transceiver SFP_DDM_WARNING_1 inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmPortEntry 10 } pme1008AlmDwCaisPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client AIS Inserted :This OID indicates a CAIS has been inserted on the output client port. This status indicates if a Client Alarm Indication Signal is currently inserted on the client interface DW_CAIS_1 informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmPortEntry 9 } pme1008AlmClientRemoteOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Remote Client Port In Service :This OID indicates that the remote Client port is In Service (1) or Out of Service (2) This status indicates if the remote client port is in service CLIENT_REMOTE_OOS informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmPortEntry 8 } pme1008AlmClientLocalOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Local Client Port In Service :This OID indicates that the local Client port is In Service (1) or Out of Service (2) This status indicates if the local client port is in service CLIENT_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmPortEntry 7 } pme1008AlmDwLsdPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Laser Shutdown :This OID indicates the Client transceiver laser is shutdown This status indicates if the client transceiver laser is shutdown DW_LSD_1 other (1) equipmentAlarm (5) (2) " ::= { pme1008AlmsynthAlmPortEntry 6 } pme1008AlmHwFailAccPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client HW Fail :This OID indicates a failure on client port, most probably caused by a HW issue. This alarm indicates a failure on client port, most probably caused by a HW issue. HW_FAIL_ACC_1 equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmPortEntry 5 } pme1008AlmDdmAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " DDM Supported On Client Trscv :This OID indicates that the Client transceiver supports the Digital Diagnostic Monitoring function This status indicates if the client transceiver includes the DDM feature DDM_ABSENT_1 informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmPortEntry 3 } pme1008AlmSfpAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Absent :This OID indicates that the Transceiver is not present in the client port. This alarm indicates if the client transceiver is not plugged SFP_ABSENT_1 inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pme1008AlmsynthAlmPortEntry 2 } --- ********************************************************* --- TABLE for the pme1008AlmsynthAlmLine articles --- ********************************************************* pme1008AlmsynthAlmLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmsynthAlmLine Article " ::= { pme1008AlmLineCrit 24 } pme1008AlmsynthAlmLineEntry OBJECT-TYPE SYNTAX Pme1008AlmsynthAlmLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmsynthAlmLine table " INDEX { pme1008AlmsynthAlmLineIndex } ::= { pme1008AlmsynthAlmLineTable 1 } Pme1008AlmsynthAlmLineEntry ::= SEQUENCE { pme1008AlmsynthAlmLineIndex INTEGER, pme1008AlmLineFailPortn EkiOnOff, pme1008AlmLineDdmAlmPortn EkiOnOff, pme1008AlmLineDdmWarningPortn EkiOnOff, pme1008AlmUpRdiInsPortn EkiOnOff, pme1008AlmLineLocalOosPortn EkiOnOff, pme1008AlmLineTxOffPortn EkiOnOff, pme1008AlmLineHwFailPortn EkiOnOff, pme1008AlmLineDdmAbsentPortn EkiOnOff, pme1008AlmLineSfpAbsentPortn EkiOnOff } pme1008AlmsynthAlmLineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmsynthAlmLine table " ::= { pme1008AlmsynthAlmLineEntry 1 } pme1008AlmLineFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port This alarm indicates a failure on the line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmLineEntry 13 } pme1008AlmLineDdmAlmPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line transceiver DDM This alarm indicates if a DDM Alarm has been detected on the line transceiver LINE_DDM_ALM inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmLineEntry 11 } pme1008AlmLineDdmWarningPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line transceiver DDM This alarm indicates if a DDM Warning has been detected on the line transceiver LINE_DDM_WARNING inputOutputDeviceError (24) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmLineEntry 10 } pme1008AlmUpRdiInsPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " MS-RDI/L-RDI Inserted On Line :This OID indicates an upstream MS-RDI/L-RDI has been inserted in the outgoing 10 Gb/s SDH/SONET signal. This status indicates if a MS-RDI/L-RDI is currently inserted on the line interface. UP_RDI_INS informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmLineEntry 9 } pme1008AlmLineLocalOosPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port In Service :This OID indicates that the Line port is In Service (1) of Out or Service (2) This status indicates if the line port is in service LINE_LOCAL_OOS informationalStatus(1000) other (1) (2) " ::= { pme1008AlmsynthAlmLineEntry 7 } pme1008AlmLineTxOffPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Laser Shutdown :This OID indicates the Line transceiver laser is shutdown This status indicates if the Line transceiver laser is shutdown LINE_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pme1008AlmsynthAlmLineEntry 6 } pme1008AlmLineHwFailPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue This alarm indicates a failure on line port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pme1008AlmsynthAlmLineEntry 5 } pme1008AlmLineDdmAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Ready :This OID indicates that the optical interface is not operational. This status indicates if the line transceiver has been correctly initialized LINE_DDM_ABSENT_1 equipmentMalfunction (16) other (1) (2) " ::= { pme1008AlmsynthAlmLineEntry 3 } pme1008AlmLineSfpAbsentPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Absent :This OID indicates that the line optical interface is not present. This alarm indicates if the line transceiver is not plugged LINE_SFP_ABSENT_1 inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pme1008AlmsynthAlmLineEntry 2 } --- ********************************************************* --- TABLE for the pme1008AlmclientHostLaneFault articles --- ********************************************************* pme1008AlmclientHostLaneFaultTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmclientHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmclientHostLaneFault Article " ::= { pme1008AlmClientUrg 88 } pme1008AlmclientHostLaneFaultEntry OBJECT-TYPE SYNTAX Pme1008AlmclientHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmclientHostLaneFault table " INDEX { pme1008AlmclientHostLaneFaultIndex } ::= { pme1008AlmclientHostLaneFaultTable 1 } Pme1008AlmclientHostLaneFaultEntry ::= SEQUENCE { pme1008AlmclientHostLaneFaultIndex INTEGER, pme1008AlmClientLaneTxFifoErrorPortn EkiOnOff, pme1008AlmClientCsfDetectedPortn EkiOnOff, pme1008AlmClientInputLossOfSigPortn EkiOnOff, pme1008AlmClientLossOfSyncPortn EkiOnOff } pme1008AlmclientHostLaneFaultIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmclientHostLaneFault table " ::= { pme1008AlmclientHostLaneFaultEntry 1 } pme1008AlmClientLaneTxFifoErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Tx FIFO Error :This OID indicates a Tx FIFO Error on the Client Trscv Alarm indicating a Tx FIFO Error on the Client Trscv CLIENT_LANE_TX_FIFO_ERROR receiverFailure (42) equipmentAlarm (5) (2) " ::= { pme1008AlmclientHostLaneFaultEntry 11 } pme1008AlmClientCsfDetectedPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Signal Fail Detected :This OID indicates that a CSF has been detected on client port in the downstream direction This alarm indicates if a Client Signal Fail has been detected in the incoming line frame for this client port CLIENT_CSF_DETECTED receiveFailure (41) other(1) (2) " ::= { pme1008AlmclientHostLaneFaultEntry 7 } pme1008AlmClientInputLossOfSigPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Client Trscv Alarm indicating a Loss of Signal is detected on the Client Trscv CLIENT_INPUT_LOSS_OF_SIG receiveFailure (41) physicalViolation (9) (2) " ::= { pme1008AlmclientHostLaneFaultEntry 3 } pme1008AlmClientLossOfSyncPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Frame Alignment Loss :This OID indicates the module is not aligned with the incoming Client signal Alarm indicating the module is not aligned with the incoming client signal CLIENT_LOSS_OF_SYNC receiveFailure (41) integrityViolation (7) (2) " ::= { pme1008AlmclientHostLaneFaultEntry 2 } --- ********************************************************* --- TABLE for the pme1008AlmlineNetworkLaneAlarmWarning1 articles --- ********************************************************* pme1008AlmlineNetworkLaneAlarmWarning1Table OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmlineNetworkLaneAlarmWarning1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmlineNetworkLaneAlarmWarning1 Article " ::= { pme1008AlmLineUrg 104 } pme1008AlmlineNetworkLaneAlarmWarning1Entry OBJECT-TYPE SYNTAX Pme1008AlmlineNetworkLaneAlarmWarning1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmlineNetworkLaneAlarmWarning1 table " INDEX { pme1008AlmlineNetworkLaneAlarmWarning1Index } ::= { pme1008AlmlineNetworkLaneAlarmWarning1Table 1 } Pme1008AlmlineNetworkLaneAlarmWarning1Entry ::= SEQUENCE { pme1008AlmlineNetworkLaneAlarmWarning1Index INTEGER, pme1008AlmLineRxPwrHighAlaPortn EkiOnOff, pme1008AlmLineRxPwrLowAlaPortn EkiOnOff, pme1008AlmLineTempHighAlaPortn EkiOnOff, pme1008AlmLineTempLowAlaPortn EkiOnOff, pme1008AlmLineVccHighAlaPortn EkiOnOff, pme1008AlmLineVccLowAlaPortn EkiOnOff, pme1008AlmLineTxBiasHighAlaPortn EkiOnOff, pme1008AlmLineTxBiasLowAlaPortn EkiOnOff, pme1008AlmLineTxPwrHighAlaPortn EkiOnOff, pme1008AlmLineTxPwrLowAlaPortn EkiOnOff } pme1008AlmlineNetworkLaneAlarmWarning1Index OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmlineNetworkLaneAlarmWarning1 table " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 1 } pme1008AlmLineRxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM LINE_RX_PWR_HIGH_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 17 } pme1008AlmLineRxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM LINE_RX_PWR_LOW_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 16 } pme1008AlmLineTempHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM LINE_TEMP_HIGH_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 9 } pme1008AlmLineTempLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM LINE_TEMP_LOW_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 8 } pme1008AlmLineVccHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM LINE_VCC_HIGH_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 7 } pme1008AlmLineVccLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM LINE_VCC_LOW_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 6 } pme1008AlmLineTxBiasHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 5 } pme1008AlmLineTxBiasLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 4 } pme1008AlmLineTxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM LINE_TX_PWR_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 3 } pme1008AlmLineTxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM LINE_TX_PWR_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning1Entry 2 } --- ********************************************************* --- TABLE for the pme1008AlmlineNetworkLaneAlarmWarning2 articles --- ********************************************************* pme1008AlmlineNetworkLaneAlarmWarning2Table OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmlineNetworkLaneAlarmWarning2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmlineNetworkLaneAlarmWarning2 Article " ::= { pme1008AlmLineUrg 120 } pme1008AlmlineNetworkLaneAlarmWarning2Entry OBJECT-TYPE SYNTAX Pme1008AlmlineNetworkLaneAlarmWarning2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmlineNetworkLaneAlarmWarning2 table " INDEX { pme1008AlmlineNetworkLaneAlarmWarning2Index } ::= { pme1008AlmlineNetworkLaneAlarmWarning2Table 1 } Pme1008AlmlineNetworkLaneAlarmWarning2Entry ::= SEQUENCE { pme1008AlmlineNetworkLaneAlarmWarning2Index INTEGER, pme1008AlmLineRxPwrHighWngPortn EkiOnOff, pme1008AlmLineRxPwrLowWngPortn EkiOnOff, pme1008AlmLineTempHighWngPortn EkiOnOff, pme1008AlmLineTempLowWngPortn EkiOnOff, pme1008AlmLineVccHighWngPortn EkiOnOff, pme1008AlmLineVccLowWngPortn EkiOnOff, pme1008AlmLineTxBiasHighWngPortn EkiOnOff, pme1008AlmLineTxBiasLowWngPortn EkiOnOff, pme1008AlmLineTxPwrHighWngPortn EkiOnOff, pme1008AlmLineTxPwLowWngPortn EkiOnOff } pme1008AlmlineNetworkLaneAlarmWarning2Index OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmlineNetworkLaneAlarmWarning2 table " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 1 } pme1008AlmLineRxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is higher than the threshold value written in the Trscv EEPROM LINE_RX_PWR_HIGH_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 17 } pme1008AlmLineRxPwrLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is lower than the threshold value written in the Trscv EEPROM LINE_RX_PWR_LOW_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 16 } pme1008AlmLineTempHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM LINE_TEMP_HIGH_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 9 } pme1008AlmLineTempLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM LINE_TEMP_LOW_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 8 } pme1008AlmLineVccHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM LINE_VCC_HIGH_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 7 } pme1008AlmLineVccLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM LINE_VCC_LOW_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 6 } pme1008AlmLineTxBiasHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 5 } pme1008AlmLineTxBiasLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM LINE_TX_BIAS_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 4 } pme1008AlmLineTxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is higher than the threshold value written in the Trscv EEPROM LINE_TX_PWR_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 3 } pme1008AlmLineTxPwLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is lower than the threshold value written in the Trscv EEPROM LINE_TX_PW_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmlineNetworkLaneAlarmWarning2Entry 2 } --- ********************************************************* --- TABLE for the pme1008AlmlineHostLaneFault articles --- ********************************************************* pme1008AlmlineHostLaneFaultTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmlineHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmlineHostLaneFault Article " ::= { pme1008AlmLineUrg 152 } pme1008AlmlineHostLaneFaultEntry OBJECT-TYPE SYNTAX Pme1008AlmlineHostLaneFaultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmlineHostLaneFault table " INDEX { pme1008AlmlineHostLaneFaultIndex } ::= { pme1008AlmlineHostLaneFaultTable 1 } Pme1008AlmlineHostLaneFaultEntry ::= SEQUENCE { pme1008AlmlineHostLaneFaultIndex INTEGER, pme1008AlmLineLossOfFramePortn EkiOnOff, pme1008AlmLineInputLossOfSignalPortn EkiOnOff } pme1008AlmlineHostLaneFaultIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmlineHostLaneFault table " ::= { pme1008AlmlineHostLaneFaultEntry 1 } pme1008AlmLineLossOfFramePortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Loss Of Frame :This OID indicates the module is not aligned with the incoming Line signal This alarm indicates if a Loss Of Frame has been detected on the line port LINE_LOSS_OF_FRAME receiveFailure (41) integrityViolation (7) (2) " ::= { pme1008AlmlineHostLaneFaultEntry 3 } pme1008AlmLineInputLossOfSignalPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Input Loss Of Signal :This OID indicates a Loss of Signal is detected on the Line Trscv This alarm indicates if an Optical Path Break has been detected on the line port LINE_INPUT_LOSS_OF_SIGNAL receiveFailure (41) physicalViolation (9) (2) " ::= { pme1008AlmlineHostLaneFaultEntry 2 } --- ********************************************************* --- TABLE for the pme1008AlmclientSfpAlmDdm articles --- ********************************************************* pme1008AlmclientSfpAlmDdmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmclientSfpAlmDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmclientSfpAlmDdm Article " ::= { pme1008AlmClientUrg 216 } pme1008AlmclientSfpAlmDdmEntry OBJECT-TYPE SYNTAX Pme1008AlmclientSfpAlmDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmclientSfpAlmDdm table " INDEX { pme1008AlmclientSfpAlmDdmIndex } ::= { pme1008AlmclientSfpAlmDdmTable 1 } Pme1008AlmclientSfpAlmDdmEntry ::= SEQUENCE { pme1008AlmclientSfpAlmDdmIndex INTEGER, pme1008AlmClientRxPwrHighAlaPortn EkiOnOff, pme1008AlmClientRxPwrLowAlaPortn EkiOnOff, pme1008AlmClientTempHighAlaPortn EkiOnOff, pme1008AlmClientTempLowAlaPortn EkiOnOff, pme1008AlmClientVccHighAlaPortn EkiOnOff, pme1008AlmClientVccLowAlaPortn EkiOnOff, pme1008AlmClientTxBiasHighAlaPortn EkiOnOff, pme1008AlmClientTxBiasLowAlaPortn EkiOnOff, pme1008AlmClientTxPwrHighAlaPortn EkiOnOff, pme1008AlmClientTxPwrLowAlaPortn EkiOnOff } pme1008AlmclientSfpAlmDdmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmclientSfpAlmDdm table " ::= { pme1008AlmclientSfpAlmDdmEntry 1 } pme1008AlmClientRxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power High :This OID indicates that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is higher than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_HIGH_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 17 } pme1008AlmClientRxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power Low :This OID indicates that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv input power of port is lower than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_LOW_ALA_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 16 } pme1008AlmClientTempHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp High :This OID indicates that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TEMP_HIGH_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 9 } pme1008AlmClientTempLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp Low :This OID indicates that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv temperature of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TEMP_LOW_ALA_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 8 } pme1008AlmClientVccHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply High :This OID indicates that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is higher than the threshold value written in the Trscv EEPROM CLIENT_VCC_HIGH_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 7 } pme1008AlmClientVccLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM CLIENT_VCC_LOW_ALA_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 6 } pme1008AlmClientTxBiasHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias High :This OID indicates that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 5 } pme1008AlmClientTxBiasLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias Low :This OID indicates that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv laser bias current of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 4 } pme1008AlmClientTxPwrHighAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power High :This OID indicates that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_HIGH_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 3 } pme1008AlmClientTxPwrLowAlaPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power Low :This OID indicates that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM Alarm indicating that the Trscv output power of port is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_LOW_ALA_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpAlmDdmEntry 2 } --- ********************************************************* --- TABLE for the pme1008AlmclientSfpWarnDdm articles --- ********************************************************* pme1008AlmclientSfpWarnDdmTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008AlmclientSfpWarnDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008AlmclientSfpWarnDdm Article " ::= { pme1008AlmClientNurg 232 } pme1008AlmclientSfpWarnDdmEntry OBJECT-TYPE SYNTAX Pme1008AlmclientSfpWarnDdmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008AlmclientSfpWarnDdm table " INDEX { pme1008AlmclientSfpWarnDdmIndex } ::= { pme1008AlmclientSfpWarnDdmTable 1 } Pme1008AlmclientSfpWarnDdmEntry ::= SEQUENCE { pme1008AlmclientSfpWarnDdmIndex INTEGER, pme1008AlmClientRxPwrHighWngPortn EkiOnOff, pme1008AlmClientRxPwrLowWngPortn EkiOnOff, pme1008AlmClientTempHighWngPortn EkiOnOff, pme1008AlmClientTempLowWngPortn EkiOnOff, pme1008AlmClientVccHighWngPortn EkiOnOff, pme1008AlmClientVccLowWngPortn EkiOnOff, pme1008AlmClientTxBiasHighWngPortn EkiOnOff, pme1008AlmClientTxBiasLowWngPortn EkiOnOff, pme1008AlmClientTxPwrHighWngPortn EkiOnOff, pme1008AlmClientTxPwLowWngPortn EkiOnOff } pme1008AlmclientSfpWarnDdmIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008AlmclientSfpWarnDdm table " ::= { pme1008AlmclientSfpWarnDdmEntry 1 } pme1008AlmClientRxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power High Warning :This OID indicates that the Trscv input power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is higher than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_HIGH_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 17 } pme1008AlmClientRxPwrLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv input power is lower than the threshold value written in the Trscv EEPROM CLIENT_RX_PWR_LOW_WNG_1 receiveFailure (41) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 16 } pme1008AlmClientTempHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp High Warning :This OID indicates that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is higher than the threshold value written in the Trscv EEPROM CLIENT_TEMP_HIGH_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 9 } pme1008AlmClientTempLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Temp Low Warning :This OID indicates that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv temperature is lower than the threshold value written in the Trscv EEPROM CLIENT_TEMP_LOW_WNG_1 temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 8 } pme1008AlmClientVccHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply High Warning :This OID indicates that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is higher than the threshold value written in the Trscv EEPROM CLIENT_VCC_HIGH_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 7 } pme1008AlmClientVccLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Power Supply Low Warning :This OID indicates that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv power supply is lower than the threshold value written in the Trscv EEPROM CLIENT_VCC_LOW_WNG_1 powerProblem (36) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 6 } pme1008AlmClientTxBiasHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 5 } pme1008AlmClientTxBiasLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Bias Low Warning :This OID indicates that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv laser bias current is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_BIAS_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 4 } pme1008AlmClientTxPwrHighWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power High Warning :This OID indicates that the Trscv output power is higher than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is higher than the threshold value written in the Trscv EEPROM CLIENT_TX_PWR_HIGH_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 3 } pme1008AlmClientTxPwLowWngPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Trscv Tx Power Low Warning :This OID indicates that the Trscv output power is lower than the threshold value written in the Trscv EEPROM Warning indicating that the Trscv output power is lower than the threshold value written in the Trscv EEPROM CLIENT_TX_PW_LOW_WNG_1 transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pme1008AlmclientSfpWarnDdmEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the confMgnt1 article --- ***************************************************** pme1008CtrlconfMgnt1 OBJECT IDENTIFIER ::= { pme1008CtrlOther 1 } pme1008CtrlConf2Clear1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This OID clears the configuration tables from configuration2 in the flash. This control restores the default configuration of the module " ::= { pme1008CtrlconfMgnt1 14 } pme1008CtrlConf2Flash1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This OID saves the current configuration of the PM as configuration2 in the flash. This control saves the customer configuration on the module " ::= { pme1008CtrlconfMgnt1 10 } pme1008CtrlConf2Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 2 :When set this OID enables loading from flash configuration2 into the PM. " ::= { pme1008CtrlconfMgnt1 2 } pme1008CtrlConf1Load1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables Set Nb 1 :When set this OID enables loading from flash configuration1 into the PM. " ::= { pme1008CtrlconfMgnt1 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pme1008Ctrlsynth4 OBJECT IDENTIFIER ::= { pme1008CtrlOther 4 } pme1008CtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM. " ::= { pme1008Ctrlsynth4 2 } pme1008CtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM. " ::= { pme1008Ctrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pme1008CtrlswMgnt OBJECT IDENTIFIER ::= { pme1008CtrlOther 5 } pme1008CtrlLoadSwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 2 As Active :This OID, when set, loads the SW from bank2 into the PM. It must be followed by a reset. This controls selects the second SW bank as the active bank for the next module reset " ::= { pme1008CtrlswMgnt 6 } pme1008CtrlLoadSwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Software Nb 1 As Active :This OID, when set, loads the SW from bank1 into the PM. It must be followed by a reset. This controls selects the first SW bank as the active bank for the next module reset " ::= { pme1008CtrlswMgnt 5 } pme1008CtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the PM. This reset is not traffic affecting, and the configuration of PM remains unchanged. This control initiates a warm reset of the module. " ::= { pme1008CtrlswMgnt 3 } pme1008CtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the PM. This reset is traffic affecting, and the configuration of PM is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pme1008CtrlswMgnt 2 } --- ***************************************************** --- LEAF for the gwMgnt article --- ***************************************************** pme1008CtrlgwMgnt OBJECT IDENTIFIER ::= { pme1008CtrlOther 6 } pme1008CtrlLoadGwBank4 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 4 As Active :This OID, when set, loads the GW from bank4 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pme1008CtrlgwMgnt 8 } pme1008CtrlLoadGwBank3 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 3 As Active :This OID, when set, loads the GW from bank3 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the third GW bank as the active bank " ::= { pme1008CtrlgwMgnt 7 } pme1008CtrlLoadGwBank2 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 2 As Active :This OID, when set, loads the GW from bank2 (Flash) into the PM. It is followed by an automatic gateware cold reset. " ::= { pme1008CtrlgwMgnt 6 } pme1008CtrlLoadGwBank1 OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Set Gateware Nb 1 As Active :This OID, when set, loads the GW from bank1 (Flash) into the PM. It is followed by an automatic gateware cold reset. This controls initiates a cold reset of the module and select the first GW bank as the active bank " ::= { pme1008CtrlgwMgnt 5 } pme1008CtrlCurrentGwReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Active Gateware Reset :This OID, when set, resets the active gateware. It is traffic affecting. " ::= { pme1008CtrlgwMgnt 1 } --- ********************************************************* --- TABLE for the pme1008CtrlaccessLoop articles --- ********************************************************* pme1008CtrlaccessLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlaccessLoop Article " ::= { pme1008CtrlClient 16 } pme1008CtrlaccessLoopEntry OBJECT-TYPE SYNTAX Pme1008CtrlaccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlaccessLoop table " INDEX { pme1008CtrlaccessLoopIndex } ::= { pme1008CtrlaccessLoopTable 1 } Pme1008CtrlaccessLoopEntry ::= SEQUENCE { pme1008CtrlaccessLoopIndex INTEGER, pme1008CtrlaccessLoopPortn EkiState } pme1008CtrlaccessLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlaccessLoop table " ::= { pme1008CtrlaccessLoopEntry 1 } pme1008CtrlaccessLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Facility Loopback :This OID, when set at '1' puts the client port in loopback, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. This control enables the Out Loopback on the client port, looping the client input signal on the client output " ::= { pme1008CtrlaccessLoopEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlclientLoopToLine articles --- ********************************************************* pme1008CtrlclientLoopToLineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlclientLoopToLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlclientLoopToLine Article " ::= { pme1008CtrlClient 17 } pme1008CtrlclientLoopToLineEntry OBJECT-TYPE SYNTAX Pme1008CtrlclientLoopToLineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlclientLoopToLine table " INDEX { pme1008CtrlclientLoopToLineIndex } ::= { pme1008CtrlclientLoopToLineTable 1 } Pme1008CtrlclientLoopToLineEntry ::= SEQUENCE { pme1008CtrlclientLoopToLineIndex INTEGER, pme1008CtrlclientLoopToLinePortn EkiState } pme1008CtrlclientLoopToLineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlclientLoopToLine table " ::= { pme1008CtrlclientLoopToLineEntry 1 } pme1008CtrlclientLoopToLinePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Terminal Loopback :This OID, when set, puts the client port in loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. This control enables the In Loopback on the client port, looping the client output signal on the client input " ::= { pme1008CtrlclientLoopToLineEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlcsfUpIns articles --- ********************************************************* pme1008CtrlcsfUpInsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlcsfUpInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlcsfUpIns Article " ::= { pme1008CtrlClient 21 } pme1008CtrlcsfUpInsEntry OBJECT-TYPE SYNTAX Pme1008CtrlcsfUpInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlcsfUpIns table " INDEX { pme1008CtrlcsfUpInsIndex } ::= { pme1008CtrlcsfUpInsTable 1 } Pme1008CtrlcsfUpInsEntry ::= SEQUENCE { pme1008CtrlcsfUpInsIndex INTEGER, pme1008CtrlcsfUpInsPortn EkiState } pme1008CtrlcsfUpInsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlcsfUpIns table " ::= { pme1008CtrlcsfUpInsEntry 1 } pme1008CtrlcsfUpInsPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client Signal Fail Insertion :This OID, when set, inserts a client signal fail in the upstream client Port. This control inserts a Client Signal Fail for the client port " ::= { pme1008CtrlcsfUpInsEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlcaisDwIns articles --- ********************************************************* pme1008CtrlcaisDwInsTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlcaisDwInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlcaisDwIns Article " ::= { pme1008CtrlClient 22 } pme1008CtrlcaisDwInsEntry OBJECT-TYPE SYNTAX Pme1008CtrlcaisDwInsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlcaisDwIns table " INDEX { pme1008CtrlcaisDwInsIndex } ::= { pme1008CtrlcaisDwInsTable 1 } Pme1008CtrlcaisDwInsEntry ::= SEQUENCE { pme1008CtrlcaisDwInsIndex INTEGER, pme1008CtrlcaisDwInsPortn EkiState } pme1008CtrlcaisDwInsIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlcaisDwIns table " ::= { pme1008CtrlcaisDwInsEntry 1 } pme1008CtrlcaisDwInsPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Client AIS Insertion :This OID, when set, inserts a client AIS on the downstream client Port. This control inserts a Client AIS for the client port " ::= { pme1008CtrlcaisDwInsEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlclientOci articles --- ********************************************************* pme1008CtrlclientOciTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlclientOciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlclientOci Article " ::= { pme1008CtrlClient 23 } pme1008CtrlclientOciEntry OBJECT-TYPE SYNTAX Pme1008CtrlclientOciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlclientOci table " INDEX { pme1008CtrlclientOciIndex } ::= { pme1008CtrlclientOciTable 1 } Pme1008CtrlclientOciEntry ::= SEQUENCE { pme1008CtrlclientOciIndex INTEGER, pme1008CtrlclientOciPortn EkiState } pme1008CtrlclientOciIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlclientOci table " ::= { pme1008CtrlclientOciEntry 1 } pme1008CtrlclientOciPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-OCI :Label This control inserts a Client OCI " ::= { pme1008CtrlclientOciEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlclientLck articles --- ********************************************************* pme1008CtrlclientLckTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlclientLckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlclientLck Article " ::= { pme1008CtrlClient 24 } pme1008CtrlclientLckEntry OBJECT-TYPE SYNTAX Pme1008CtrlclientLckEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlclientLck table " INDEX { pme1008CtrlclientLckIndex } ::= { pme1008CtrlclientLckTable 1 } Pme1008CtrlclientLckEntry ::= SEQUENCE { pme1008CtrlclientLckIndex INTEGER, pme1008CtrlclientLckPortn EkiState } pme1008CtrlclientLckIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlclientLck table " ::= { pme1008CtrlclientLckEntry 1 } pme1008CtrlclientLckPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-LCK :Label This control inserts a Client LCK " ::= { pme1008CtrlclientLckEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlclientAis articles --- ********************************************************* pme1008CtrlclientAisTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlclientAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlclientAis Article " ::= { pme1008CtrlClient 25 } pme1008CtrlclientAisEntry OBJECT-TYPE SYNTAX Pme1008CtrlclientAisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlclientAis table " INDEX { pme1008CtrlclientAisIndex } ::= { pme1008CtrlclientAisTable 1 } Pme1008CtrlclientAisEntry ::= SEQUENCE { pme1008CtrlclientAisIndex INTEGER, pme1008CtrlclientAisPortn EkiState } pme1008CtrlclientAisIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlclientAis table " ::= { pme1008CtrlclientAisEntry 1 } pme1008CtrlclientAisPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-AIS :Label This control inserts a Client AIS " ::= { pme1008CtrlclientAisEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlclientBdi articles --- ********************************************************* pme1008CtrlclientBdiTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlclientBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlclientBdi Article " ::= { pme1008CtrlClient 26 } pme1008CtrlclientBdiEntry OBJECT-TYPE SYNTAX Pme1008CtrlclientBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlclientBdi table " INDEX { pme1008CtrlclientBdiIndex } ::= { pme1008CtrlclientBdiTable 1 } Pme1008CtrlclientBdiEntry ::= SEQUENCE { pme1008CtrlclientBdiIndex INTEGER, pme1008CtrlclientBdiPortn EkiState } pme1008CtrlclientBdiIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlclientBdi table " ::= { pme1008CtrlclientBdiEntry 1 } pme1008CtrlclientBdiPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2e-BDI :Label This control inserts a Client BDI " ::= { pme1008CtrlclientBdiEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlcommAccessLoop articles --- ********************************************************* pme1008CtrlcommAccessLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlcommAccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlcommAccessLoop Article " ::= { pme1008CtrlLine 64 } pme1008CtrlcommAccessLoopEntry OBJECT-TYPE SYNTAX Pme1008CtrlcommAccessLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlcommAccessLoop table " INDEX { pme1008CtrlcommAccessLoopIndex } ::= { pme1008CtrlcommAccessLoopTable 1 } Pme1008CtrlcommAccessLoopEntry ::= SEQUENCE { pme1008CtrlcommAccessLoopIndex INTEGER, pme1008CtrlcommAccessLoopPortn EkiState } pme1008CtrlcommAccessLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlcommAccessLoop table " ::= { pme1008CtrlcommAccessLoopEntry 1 } pme1008CtrlcommAccessLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Terminal Loopback :This OID, when set, puts the module in common access loop back, looping the 10 Gb/s output signal on the 10 Gb/s input. This control enables the In Loopback on the line port, looping the 100 Gb/s output signal on the 100 Gb/s input " ::= { pme1008CtrlcommAccessLoopEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrllineLoop articles --- ********************************************************* pme1008CtrllineLoopTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrllineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrllineLoop Article " ::= { pme1008CtrlLine 66 } pme1008CtrllineLoopEntry OBJECT-TYPE SYNTAX Pme1008CtrllineLoopEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrllineLoop table " INDEX { pme1008CtrllineLoopIndex } ::= { pme1008CtrllineLoopTable 1 } Pme1008CtrllineLoopEntry ::= SEQUENCE { pme1008CtrllineLoopIndex INTEGER, pme1008CtrllineLoopPortn EkiState } pme1008CtrllineLoopIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrllineLoop table " ::= { pme1008CtrllineLoopEntry 1 } pme1008CtrllineLoopPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Line Facility Loopback :This OID, when set at '1' puts the module in line loopback mode, looping the received 10 Gb/s signal on the transmit 10 Gb/s output. The Upstream part of the module is timed on the 10 Gb/s recovered clock in that case. This control enables the Out Loopback on the line port, looping the 100 Gb/s input signal on the 100 Gb/s output " ::= { pme1008CtrllineLoopEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrlfecDisable articles --- ********************************************************* pme1008CtrlfecDisableTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrlfecDisable Article " ::= { pme1008CtrlLine 69 } pme1008CtrlfecDisableEntry OBJECT-TYPE SYNTAX Pme1008CtrlfecDisableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrlfecDisable table " INDEX { pme1008CtrlfecDisableIndex } ::= { pme1008CtrlfecDisableTable 1 } Pme1008CtrlfecDisableEntry ::= SEQUENCE { pme1008CtrlfecDisableIndex INTEGER, pme1008CtrlfecDisablePortn EkiState } pme1008CtrlfecDisableIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrlfecDisable table " ::= { pme1008CtrlfecDisableEntry 1 } pme1008CtrlfecDisablePortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " Forward Error Correction Inhibition :This OID, when set, inhibits the Forward Error Correction feature on the line input This control enables/disables the Forward Error Correction on the line interface " ::= { pme1008CtrlfecDisableEntry 2 } --- ********************************************************* --- TABLE for the pme1008CtrllineBdi articles --- ********************************************************* pme1008CtrllineBdiTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CtrllineBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CtrllineBdi Article " ::= { pme1008CtrlLine 70 } pme1008CtrllineBdiEntry OBJECT-TYPE SYNTAX Pme1008CtrllineBdiEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CtrllineBdi table " INDEX { pme1008CtrllineBdiIndex } ::= { pme1008CtrllineBdiTable 1 } Pme1008CtrllineBdiEntry ::= SEQUENCE { pme1008CtrllineBdiIndex INTEGER, pme1008CtrllineBdiPortn EkiState } pme1008CtrllineBdiIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CtrllineBdi table " ::= { pme1008CtrllineBdiEntry 1 } pme1008CtrllineBdiPortn OBJECT-TYPE SYNTAX EkiState MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2e-BDI :Label This control inserts a Line BDI " ::= { pme1008CtrllineBdiEntry 2 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pme1008CtrlledTest OBJECT IDENTIFIER ::= { pme1008CtrlOther 192 } pme1008CtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pme1008CtrlledTest 3 } pme1008CtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pme1008CtrlledTest 2 } pme1008CtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pme1008CtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- COUNTERS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pme1008CntclientCbipCounter articles --- ********************************************************* pme1008CntclientCbipCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CntclientCbipCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CntclientCbipCounter Article " ::= { pme1008CntClient 96 } pme1008CntclientCbipCounterEntry OBJECT-TYPE SYNTAX Pme1008CntclientCbipCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CntclientCbipCounter table " INDEX { pme1008CntclientCbipCounterIndex } ::= { pme1008CntclientCbipCounterTable 1 } Pme1008CntclientCbipCounterEntry ::= SEQUENCE { pme1008CntclientCbipCounterIndex INTEGER, pme1008CntclientCbipCounterValuePortn Counter32, pme1008CntclientCbipCounterErrorPortn EkiOnOff, pme1008CntclientCbipCounterOverloadPortn EkiOnOff } pme1008CntclientCbipCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CntclientCbipCounter table " ::= { pme1008CntclientCbipCounterEntry 1 } pme1008CntclientCbipCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Output Errors :This counter is incremented each time a BIP error is detected on the Client path This counter gives the number of CBIP errors on the client path " ::= { pme1008CntclientCbipCounterEntry 2 } pme1008CntclientCbipCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Counter Error :This OID when set indicates the CBIP error counter value is invalid on Port " ::= { pme1008CntclientCbipCounterEntry 3 } pme1008CntclientCbipCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client CBIP Counter Overload :This OID when set indicates a CBIP error counter overload on Port " ::= { pme1008CntclientCbipCounterEntry 4 } --- ********************************************************* --- TABLE for the pme1008CntlocalLineSmBip8ErrorCounter articles --- ********************************************************* pme1008CntlocalLineSmBip8ErrorCounterTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CntlocalLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CntlocalLineSmBip8ErrorCounter Article " ::= { pme1008CntLine 192 } pme1008CntlocalLineSmBip8ErrorCounterEntry OBJECT-TYPE SYNTAX Pme1008CntlocalLineSmBip8ErrorCounterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CntlocalLineSmBip8ErrorCounter table " INDEX { pme1008CntlocalLineSmBip8ErrorCounterIndex } ::= { pme1008CntlocalLineSmBip8ErrorCounterTable 1 } Pme1008CntlocalLineSmBip8ErrorCounterEntry ::= SEQUENCE { pme1008CntlocalLineSmBip8ErrorCounterIndex INTEGER, pme1008CntlocalLineSmBip8ErrorCounterValuePortn Counter32, pme1008CntlocalLineSmBip8ErrorCounterErrorPortn EkiOnOff, pme1008CntlocalLineSmBip8ErrorCounterOverloadPortn EkiOnOff } pme1008CntlocalLineSmBip8ErrorCounterIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CntlocalLineSmBip8ErrorCounter table " ::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 1 } pme1008CntlocalLineSmBip8ErrorCounterValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Input FCS Errors :This counter is increased each time a FCS error is detected on the line input stream This counter gives the number of FCS errors on the line input port " ::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 2 } pme1008CntlocalLineSmBip8ErrorCounterErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the B1 error counter value is invalid on Port " ::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 3 } pme1008CntlocalLineSmBip8ErrorCounterOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a B1 error counter overload on Port " ::= { pme1008CntlocalLineSmBip8ErrorCounterEntry 4 } --- ********************************************************* --- TABLE for the pme1008CntlineDfrmTimCnt articles --- ********************************************************* pme1008CntlineDfrmTimCntTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CntlineDfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008CntlineDfrmTimCnt Article " ::= { pme1008CntLine 216 } pme1008CntlineDfrmTimCntEntry OBJECT-TYPE SYNTAX Pme1008CntlineDfrmTimCntEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008CntlineDfrmTimCnt table " INDEX { pme1008CntlineDfrmTimCntIndex } ::= { pme1008CntlineDfrmTimCntTable 1 } Pme1008CntlineDfrmTimCntEntry ::= SEQUENCE { pme1008CntlineDfrmTimCntIndex INTEGER, pme1008CntlineDfrmTimCntValuePortn Counter32, pme1008CntlineDfrmTimCntErrorPortn EkiOnOff, pme1008CntlineDfrmTimCntOverloadPortn EkiOnOff } pme1008CntlineDfrmTimCntIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008CntlineDfrmTimCnt table " ::= { pme1008CntlineDfrmTimCntEntry 1 } pme1008CntlineDfrmTimCntValuePortn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION " Line Timer Counter : " ::= { pme1008CntlineDfrmTimCntEntry 2 } pme1008CntlineDfrmTimCntErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Error :This OID when set indicates the deframer timer counter value is invalid on Port " ::= { pme1008CntlineDfrmTimCntEntry 3 } pme1008CntlineDfrmTimCntOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Counter Overload :This OID when set indicates a deframer timer counter overload on Port " ::= { pme1008CntlineDfrmTimCntEntry 4 } pme1008CntCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters Reset:This OID resets and restarts all the counters" ::= { pme1008counters 259 } pme1008CntCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Counters stop:This OID stops all the counters" ::= { pme1008counters 260 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- RMON --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pme1008MonupRmonBytesCounterClientInput articles --- ********************************************************* pme1008MonupRmonBytesCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonBytesCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonBytesCounterClientInput Article " ::= { pme1008MonClientRmonCounter 16 } pme1008MonupRmonBytesCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonBytesCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonBytesCounterClientInput table " INDEX { pme1008MonupRmonBytesCounterClientInputIndex } ::= { pme1008MonupRmonBytesCounterClientInputTable 1 } Pme1008MonupRmonBytesCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonBytesCounterClientInputIndex INTEGER, pme1008MonupRmonBytesCounterClientInputValuePortn Counter64, pme1008MonupRmonBytesCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonBytesCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonBytesCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonBytesCounterClientInput table " ::= { pme1008MonupRmonBytesCounterClientInputEntry 1 } pme1008MonupRmonBytesCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Bytes :This counter is increased each time a data byte is received on the client port This counter gives the number of bytes received on the client port " ::= { pme1008MonupRmonBytesCounterClientInputEntry 2 } pme1008MonupRmonBytesCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Bytes Counter Error :This OID when set indicates the Bytes counter value is invalid on client port " ::= { pme1008MonupRmonBytesCounterClientInputEntry 3 } pme1008MonupRmonBytesCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Bytes Counter Overload :This OID when set indicates a Bytes counter overload on client port " ::= { pme1008MonupRmonBytesCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MonupRmonCrcErrorsCounterClientInput articles --- ********************************************************* pme1008MonupRmonCrcErrorsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonCrcErrorsCounterClientInput Article " ::= { pme1008MonClientRmonCounter 32 } pme1008MonupRmonCrcErrorsCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonCrcErrorsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonCrcErrorsCounterClientInput table " INDEX { pme1008MonupRmonCrcErrorsCounterClientInputIndex } ::= { pme1008MonupRmonCrcErrorsCounterClientInputTable 1 } Pme1008MonupRmonCrcErrorsCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonCrcErrorsCounterClientInputIndex INTEGER, pme1008MonupRmonCrcErrorsCounterClientInputValuePortn Counter64, pme1008MonupRmonCrcErrorsCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonCrcErrorsCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonCrcErrorsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonCrcErrorsCounterClientInput table " ::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 1 } pme1008MonupRmonCrcErrorsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input CRC Errors :This counter is increased each time a B1/FCS error is detected on the client port This counter gives the number of B1/FCS Errors received on the client port " ::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 2 } pme1008MonupRmonCrcErrorsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " B1/FCS Errors Counter Error :This OID when set indicates the B1/FCS Errors counter value is invalid on client port " ::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 3 } pme1008MonupRmonCrcErrorsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " B1/FCS Errors Counter Overload :This OID when set indicates a B1/FCS Errors counter overload on client port " ::= { pme1008MonupRmonCrcErrorsCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MonupRmonPacketsCounterClientInput articles --- ********************************************************* pme1008MonupRmonPacketsCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonPacketsCounterClientInput Article " ::= { pme1008MonClientRmonCounter 48 } pme1008MonupRmonPacketsCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonPacketsCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonPacketsCounterClientInput table " INDEX { pme1008MonupRmonPacketsCounterClientInputIndex } ::= { pme1008MonupRmonPacketsCounterClientInputTable 1 } Pme1008MonupRmonPacketsCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonPacketsCounterClientInputIndex INTEGER, pme1008MonupRmonPacketsCounterClientInputValuePortn Counter64, pme1008MonupRmonPacketsCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonPacketsCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonPacketsCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonPacketsCounterClientInput table " ::= { pme1008MonupRmonPacketsCounterClientInputEntry 1 } pme1008MonupRmonPacketsCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Packets :This counter is increased each time a packet is received on the client port This counter gives the number of packets received on the client port " ::= { pme1008MonupRmonPacketsCounterClientInputEntry 2 } pme1008MonupRmonPacketsCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Packets Counter Error :This OID when set indicates the Packets counter value is invalid on client port " ::= { pme1008MonupRmonPacketsCounterClientInputEntry 3 } pme1008MonupRmonPacketsCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Packets Counter Overload :This OID when set indicates a Packets counter overload on client port " ::= { pme1008MonupRmonPacketsCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MonupRmonBroadcastCounterClientInput articles --- ********************************************************* pme1008MonupRmonBroadcastCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonBroadcastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonBroadcastCounterClientInput Article " ::= { pme1008MonClientRmonCounter 64 } pme1008MonupRmonBroadcastCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonBroadcastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonBroadcastCounterClientInput table " INDEX { pme1008MonupRmonBroadcastCounterClientInputIndex } ::= { pme1008MonupRmonBroadcastCounterClientInputTable 1 } Pme1008MonupRmonBroadcastCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonBroadcastCounterClientInputIndex INTEGER, pme1008MonupRmonBroadcastCounterClientInputValuePortn Counter64, pme1008MonupRmonBroadcastCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonBroadcastCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonBroadcastCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonBroadcastCounterClientInput table " ::= { pme1008MonupRmonBroadcastCounterClientInputEntry 1 } pme1008MonupRmonBroadcastCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Broadcast Packets :This counter is increased each time a broadcast packet is received on the client port This counter gives the number of Broadcast packets received on the client port " ::= { pme1008MonupRmonBroadcastCounterClientInputEntry 2 } pme1008MonupRmonBroadcastCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Broadcast Counter Error :This OID when set indicates the Broadcast counter value is invalid on client port " ::= { pme1008MonupRmonBroadcastCounterClientInputEntry 3 } pme1008MonupRmonBroadcastCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Broadcast Counter Overload :This OID when set indicates a Broadcast counter overload on client port " ::= { pme1008MonupRmonBroadcastCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MonupRmonMulticastCounterClientInput articles --- ********************************************************* pme1008MonupRmonMulticastCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonMulticastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonMulticastCounterClientInput Article " ::= { pme1008MonClientRmonCounter 80 } pme1008MonupRmonMulticastCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonMulticastCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonMulticastCounterClientInput table " INDEX { pme1008MonupRmonMulticastCounterClientInputIndex } ::= { pme1008MonupRmonMulticastCounterClientInputTable 1 } Pme1008MonupRmonMulticastCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonMulticastCounterClientInputIndex INTEGER, pme1008MonupRmonMulticastCounterClientInputValuePortn Counter64, pme1008MonupRmonMulticastCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonMulticastCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonMulticastCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonMulticastCounterClientInput table " ::= { pme1008MonupRmonMulticastCounterClientInputEntry 1 } pme1008MonupRmonMulticastCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Multicast Packets :This counter is increased each time a Multicast packet is received on the client port This counter gives the number of Multicast packets received on the client port " ::= { pme1008MonupRmonMulticastCounterClientInputEntry 2 } pme1008MonupRmonMulticastCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Multicast Counter Error :This OID when set indicates the Multicast counter value is invalid on client port " ::= { pme1008MonupRmonMulticastCounterClientInputEntry 3 } pme1008MonupRmonMulticastCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Multicast Counter Overload :This OID when set indicates a Multicast counter overload on client port " ::= { pme1008MonupRmonMulticastCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MonupRmonPauseFrameCounterClientInput articles --- ********************************************************* pme1008MonupRmonPauseFrameCounterClientInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MonupRmonPauseFrameCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MonupRmonPauseFrameCounterClientInput Article " ::= { pme1008MonClientRmonCounter 96 } pme1008MonupRmonPauseFrameCounterClientInputEntry OBJECT-TYPE SYNTAX Pme1008MonupRmonPauseFrameCounterClientInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MonupRmonPauseFrameCounterClientInput table " INDEX { pme1008MonupRmonPauseFrameCounterClientInputIndex } ::= { pme1008MonupRmonPauseFrameCounterClientInputTable 1 } Pme1008MonupRmonPauseFrameCounterClientInputEntry ::= SEQUENCE { pme1008MonupRmonPauseFrameCounterClientInputIndex INTEGER, pme1008MonupRmonPauseFrameCounterClientInputValuePortn Counter64, pme1008MonupRmonPauseFrameCounterClientInputErrorPortn EkiOnOff, pme1008MonupRmonPauseFrameCounterClientInputOverloadPortn EkiOnOff } pme1008MonupRmonPauseFrameCounterClientInputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MonupRmonPauseFrameCounterClientInput table " ::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 1 } pme1008MonupRmonPauseFrameCounterClientInputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Input Pause Frames :This counter is increased each time a Pause frame is received on the client port This counter gives the number of Pause frames received on the client port " ::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 2 } pme1008MonupRmonPauseFrameCounterClientInputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pause Counter Error :This OID when set indicates the Pause counter value is invalid on client port " ::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 3 } pme1008MonupRmonPauseFrameCounterClientInputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pause Counter Overload :This OID when set indicates a Pause counter overload on client port " ::= { pme1008MonupRmonPauseFrameCounterClientInputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MondwRmonCrcErrorsCounterClientOutput articles --- ********************************************************* pme1008MondwRmonCrcErrorsCounterClientOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MondwRmonCrcErrorsCounterClientOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MondwRmonCrcErrorsCounterClientOutput Article " ::= { pme1008MonClientRmonCounter 224 } pme1008MondwRmonCrcErrorsCounterClientOutputEntry OBJECT-TYPE SYNTAX Pme1008MondwRmonCrcErrorsCounterClientOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MondwRmonCrcErrorsCounterClientOutput table " INDEX { pme1008MondwRmonCrcErrorsCounterClientOutputIndex } ::= { pme1008MondwRmonCrcErrorsCounterClientOutputTable 1 } Pme1008MondwRmonCrcErrorsCounterClientOutputEntry ::= SEQUENCE { pme1008MondwRmonCrcErrorsCounterClientOutputIndex INTEGER, pme1008MondwRmonCrcErrorsCounterClientOutputValuePortn Counter64, pme1008MondwRmonCrcErrorsCounterClientOutputErrorPortn EkiOnOff, pme1008MondwRmonCrcErrorsCounterClientOutputOverloadPortn EkiOnOff } pme1008MondwRmonCrcErrorsCounterClientOutputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MondwRmonCrcErrorsCounterClientOutput table " ::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 1 } pme1008MondwRmonCrcErrorsCounterClientOutputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Output B1/CRC Errors :This counter is increased each time a B1/FCS error is detected on the output client port This counter gives the number of B1/CRC Errors detected on the client port " ::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 2 } pme1008MondwRmonCrcErrorsCounterClientOutputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output B1/FCS Errors Counter Error :This OID when set indicates the output B1/FCS Errors counter value is invalid on client port " ::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 3 } pme1008MondwRmonCrcErrorsCounterClientOutputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output B1/FCS Errors Counter Overload :This OID when set indicates an output B1/FCS Errors counter overload on client port " ::= { pme1008MondwRmonCrcErrorsCounterClientOutputEntry 4 } --- ********************************************************* --- TABLE for the pme1008MondwRmonPacketsCounterClientOutput articles --- ********************************************************* pme1008MondwRmonPacketsCounterClientOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MondwRmonPacketsCounterClientOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MondwRmonPacketsCounterClientOutput Article " ::= { pme1008MonClientRmonCounter 240 } pme1008MondwRmonPacketsCounterClientOutputEntry OBJECT-TYPE SYNTAX Pme1008MondwRmonPacketsCounterClientOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MondwRmonPacketsCounterClientOutput table " INDEX { pme1008MondwRmonPacketsCounterClientOutputIndex } ::= { pme1008MondwRmonPacketsCounterClientOutputTable 1 } Pme1008MondwRmonPacketsCounterClientOutputEntry ::= SEQUENCE { pme1008MondwRmonPacketsCounterClientOutputIndex INTEGER, pme1008MondwRmonPacketsCounterClientOutputValuePortn Counter64, pme1008MondwRmonPacketsCounterClientOutputErrorPortn EkiOnOff, pme1008MondwRmonPacketsCounterClientOutputOverloadPortn EkiOnOff } pme1008MondwRmonPacketsCounterClientOutputIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MondwRmonPacketsCounterClientOutput table " ::= { pme1008MondwRmonPacketsCounterClientOutputEntry 1 } pme1008MondwRmonPacketsCounterClientOutputValuePortn OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION " Client Output Packets :This counter is increased each time a packet is transmitted on the client port. This counter gives the number of packets detected on the client port " ::= { pme1008MondwRmonPacketsCounterClientOutputEntry 2 } pme1008MondwRmonPacketsCounterClientOutputErrorPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output Packets Counter Error :This OID when set indicates the output Packets counter value is invalid on client port " ::= { pme1008MondwRmonPacketsCounterClientOutputEntry 3 } pme1008MondwRmonPacketsCounterClientOutputOverloadPortn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Output Packets Counter Overload :This OID when set indicates an output Packets counter overload on client port " ::= { pme1008MondwRmonPacketsCounterClientOutputEntry 4 } pme1008MonCountersReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "RMON Counters Reset:This OID resets and restarts all the RMON counters" ::= { pme1008MonRmon 359 } pme1008MonCountersStop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "RMON Counters stop:This OID stops all the RMON counters" ::= { pme1008MonRmon 360 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ********************************************************* --- TABLE for the pme1008MesrclientTemp articles --- ********************************************************* pme1008MesrclientTempTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrclientTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrclientTemp Article " ::= { pme1008MesrClient 16 } pme1008MesrclientTempEntry OBJECT-TYPE SYNTAX Pme1008MesrclientTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrclientTemp table " INDEX { pme1008MesrclientTempIndex } ::= { pme1008MesrclientTempTable 1 } Pme1008MesrclientTempEntry ::= SEQUENCE { pme1008MesrclientTempIndex INTEGER, pme1008MesrclientTempPortn INTEGER } pme1008MesrclientTempIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrclientTemp table " ::= { pme1008MesrclientTempEntry 1 } pme1008MesrclientTempPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Temperature :This OID gives the Laser temperature value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This Measure gives the Laser temperature value of the Client Transceiver " ::= { pme1008MesrclientTempEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrclientTxBias articles --- ********************************************************* pme1008MesrclientTxBiasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrclientTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrclientTxBias Article " ::= { pme1008MesrClient 32 } pme1008MesrclientTxBiasEntry OBJECT-TYPE SYNTAX Pme1008MesrclientTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrclientTxBias table " INDEX { pme1008MesrclientTxBiasIndex } ::= { pme1008MesrclientTxBiasTable 1 } Pme1008MesrclientTxBiasEntry ::= SEQUENCE { pme1008MesrclientTxBiasIndex INTEGER, pme1008MesrclientTxBiasPortn INTEGER } pme1008MesrclientTxBiasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrclientTxBias table " ::= { pme1008MesrclientTxBiasEntry 1 } pme1008MesrclientTxBiasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Laser Bias :This OID gives the Laser bias value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This Measure gives the Laser bias value of the Client Transceiver " ::= { pme1008MesrclientTxBiasEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrclientTxPwr articles --- ********************************************************* pme1008MesrclientTxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrclientTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrclientTxPwr Article " ::= { pme1008MesrClient 48 } pme1008MesrclientTxPwrEntry OBJECT-TYPE SYNTAX Pme1008MesrclientTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrclientTxPwr table " INDEX { pme1008MesrclientTxPwrIndex } ::= { pme1008MesrclientTxPwrTable 1 } Pme1008MesrclientTxPwrEntry ::= SEQUENCE { pme1008MesrclientTxPwrIndex INTEGER, pme1008MesrclientTxPwrPortn INTEGER } pme1008MesrclientTxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrclientTxPwr table " ::= { pme1008MesrclientTxPwrEntry 1 } pme1008MesrclientTxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Tx Power :This OID gives the transmit power value of the Client Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the transmit power value of the Client Transceiver " ::= { pme1008MesrclientTxPwrEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrclientRxPwr articles --- ********************************************************* pme1008MesrclientRxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrclientRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrclientRxPwr Article " ::= { pme1008MesrClient 64 } pme1008MesrclientRxPwrEntry OBJECT-TYPE SYNTAX Pme1008MesrclientRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrclientRxPwr table " INDEX { pme1008MesrclientRxPwrIndex } ::= { pme1008MesrclientRxPwrTable 1 } Pme1008MesrclientRxPwrEntry ::= SEQUENCE { pme1008MesrclientRxPwrIndex INTEGER, pme1008MesrclientRxPwrPortn INTEGER } pme1008MesrclientRxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrclientRxPwr table " ::= { pme1008MesrclientRxPwrEntry 1 } pme1008MesrclientRxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Client SFP Rx Power :This OID gives the receive power value of the Client Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the receive power value of the Client Transceiver " ::= { pme1008MesrclientRxPwrEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrlineTxPwr articles --- ********************************************************* pme1008MesrlineTxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrlineTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrlineTxPwr Article " ::= { pme1008MesrLine 80 } pme1008MesrlineTxPwrEntry OBJECT-TYPE SYNTAX Pme1008MesrlineTxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrlineTxPwr table " INDEX { pme1008MesrlineTxPwrIndex } ::= { pme1008MesrlineTxPwrTable 1 } Pme1008MesrlineTxPwrEntry ::= SEQUENCE { pme1008MesrlineTxPwrIndex INTEGER, pme1008MesrlineTxPwrPortn INTEGER } pme1008MesrlineTxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrlineTxPwr table " ::= { pme1008MesrlineTxPwrEntry 1 } pme1008MesrlineTxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Tx Power :This OID gives the Tx Laser transmit power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the Tx Laser transmit power value of the Line Transceiver " ::= { pme1008MesrlineTxPwrEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrlineTemp articles --- ********************************************************* pme1008MesrlineTempTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrlineTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrlineTemp Article " ::= { pme1008MesrLine 96 } pme1008MesrlineTempEntry OBJECT-TYPE SYNTAX Pme1008MesrlineTempEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrlineTemp table " INDEX { pme1008MesrlineTempIndex } ::= { pme1008MesrlineTempTable 1 } Pme1008MesrlineTempEntry ::= SEQUENCE { pme1008MesrlineTempIndex INTEGER, pme1008MesrlineTempPortn INTEGER } pme1008MesrlineTempIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrlineTemp table " ::= { pme1008MesrlineTempEntry 1 } pme1008MesrlineTempPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Temperature :This OID gives the Tx Laser Temperature value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This Measure gives the Tx Laser Temperature value of the Line Transceiver " ::= { pme1008MesrlineTempEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrlineTxBias articles --- ********************************************************* pme1008MesrlineTxBiasTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrlineTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrlineTxBias Article " ::= { pme1008MesrLine 112 } pme1008MesrlineTxBiasEntry OBJECT-TYPE SYNTAX Pme1008MesrlineTxBiasEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrlineTxBias table " INDEX { pme1008MesrlineTxBiasIndex } ::= { pme1008MesrlineTxBiasTable 1 } Pme1008MesrlineTxBiasEntry ::= SEQUENCE { pme1008MesrlineTxBiasIndex INTEGER, pme1008MesrlineTxBiasPortn INTEGER } pme1008MesrlineTxBiasIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrlineTxBias table " ::= { pme1008MesrlineTxBiasEntry 1 } pme1008MesrlineTxBiasPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Laser Bias :This OID gives the Tx Laser Bias value of the Line Transceiver, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This Measure gives the Tx Laser Bias value of the Line Transceiver " ::= { pme1008MesrlineTxBiasEntry 2 } --- ********************************************************* --- TABLE for the pme1008MesrlineRxPwr articles --- ********************************************************* pme1008MesrlineRxPwrTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008MesrlineRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of pme1008MesrlineRxPwr Article " ::= { pme1008MesrLine 128 } pme1008MesrlineRxPwrEntry OBJECT-TYPE SYNTAX Pme1008MesrlineRxPwrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the pme1008MesrlineRxPwr table " INDEX { pme1008MesrlineRxPwrIndex } ::= { pme1008MesrlineRxPwrTable 1 } Pme1008MesrlineRxPwrEntry ::= SEQUENCE { pme1008MesrlineRxPwrIndex INTEGER, pme1008MesrlineRxPwrPortn INTEGER } pme1008MesrlineRxPwrIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the pme1008MesrlineRxPwr table " ::= { pme1008MesrlineRxPwrEntry 1 } pme1008MesrlineRxPwrPortn OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line Optical Module Rx Power :This OID gives the Receive power value of the Line Transceiver, read in the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This Measure gives the Receive power value of the Line Transceiver " ::= { pme1008MesrlineRxPwrEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- DOWNLOAD --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the restartProcess article --- ***************************************************** pme1008DwlrestartProcess OBJECT IDENTIFIER ::= { pme1008DwlOther 0 } pme1008DwlColdRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Cold Restart :This OID indicates that the module last restart was a Cold RESTART " ::= { pme1008DwlrestartProcess 2 } pme1008DwlWarmRestartProcessed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warm Restart :This OID indicates that the module last restart was a Warm RESTART " ::= { pme1008DwlrestartProcess 1 } --- ***************************************************** --- LEAF for the swBanksUsed article --- ***************************************************** pme1008DwlswBanksUsed OBJECT IDENTIFIER ::= { pme1008DwlOther 1 } pme1008DwlSwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 loaded :This OID indicates a software is loaded in SW bank 2 This status indicates if the SW bank 2 contains SW package " ::= { pme1008DwlswBanksUsed 6 } pme1008DwlSwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 loaded :This OID indicates a software is loaded in SW bank 1 This status indicates if the SW bank 1 contains SW package " ::= { pme1008DwlswBanksUsed 5 } pme1008DwlSwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 2 active :This OID indicates the module is working on SW bank 2 This status indicates if the SW bank 2 is active or standby " ::= { pme1008DwlswBanksUsed 2 } pme1008DwlSwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " SW bank 1 active :This OID indicates the module is working on SW bank 1 This status indicates if the SW bank 1 is active or standby " ::= { pme1008DwlswBanksUsed 1 } --- ***************************************************** --- LEAF for the gwBanksUsed article --- ***************************************************** pme1008DwlgwBanksUsed OBJECT IDENTIFIER ::= { pme1008DwlOther 2 } pme1008DwlGwBank4Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 loaded :This OID indicates a gateware is loaded in GW bank 4 " ::= { pme1008DwlgwBanksUsed 8 } pme1008DwlGwBank3Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 loaded :This OID indicates a gateware is loaded in GW bank 3 This status indicates if the GW bank 3 contains GW package " ::= { pme1008DwlgwBanksUsed 7 } pme1008DwlGwBank2Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 loaded :This OID indicates a gateware is loaded in GW bank 2 " ::= { pme1008DwlgwBanksUsed 6 } pme1008DwlGwBank1Notempty OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 loaded :This OID indicates a gateware is loaded in GW bank 1 This status indicates if the GW bank 1 contains GW package " ::= { pme1008DwlgwBanksUsed 5 } pme1008DwlGwBank4Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 4 active :This OID indicates the module is working on GW bank 4 " ::= { pme1008DwlgwBanksUsed 4 } pme1008DwlGwBank3Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 3 active :This OID indicates the module is working on GW bank 3 This status indicates if the GW bank 3 is active or standby " ::= { pme1008DwlgwBanksUsed 3 } pme1008DwlGwBank2Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 2 active :This OID indicates the module is working on GW bank 2 " ::= { pme1008DwlgwBanksUsed 2 } pme1008DwlGwBank1Used OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " GW bank 1 active :This OID indicates the module is working on GW bank 1 This status indicates if the GW bank 1 is active or standby " ::= { pme1008DwlgwBanksUsed 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group startup --- ***************************************************** pme1008CfgStartup OBJECT IDENTIFIER ::= { pme1008Config 1 } --- ***************************************************** --- LEAF for the table 2110 --- ***************************************************** pme1008CfgClientStartupTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientStartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgStartup 1 } pme1008CfgClientStartupEntry OBJECT-TYPE SYNTAX Pme1008CfgClientStartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pme1008CfgClientStartupIndex } ::= { pme1008CfgClientStartupTable 1 } Pme1008CfgClientStartupEntry ::= SEQUENCE { pme1008CfgClientStartupIndex INTEGER, pme1008CfgSystConfPortPortn Unsigned32, pme1008CfgNetConfPortPortn Unsigned32, pme1008CfgOptionsPortPortn Unsigned32 } pme1008CfgClientStartupIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientStartup table " ::= { pme1008CfgClientStartupEntry 1 } pme1008CfgSystConfPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Port :This register configures the default initialisation settings on the port. " ::= { pme1008CfgClientStartupEntry 3 } pme1008CfgNetConfPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Port :This register configures the default initialisation settings on the port. " ::= { pme1008CfgClientStartupEntry 4 } pme1008CfgOptionsPortPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Client Port :This register configures the default options on the port. " ::= { pme1008CfgClientStartupEntry 14 } --- ***************************************************** --- LEAF for the table 2190 --- ***************************************************** pme1008CfgLinexr1StartupTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLinexr1StartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgStartup 2 } pme1008CfgLinexr1StartupEntry OBJECT-TYPE SYNTAX Pme1008CfgLinexr1StartupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pme1008CfgLinexr1StartupIndex } ::= { pme1008CfgLinexr1StartupTable 1 } Pme1008CfgLinexr1StartupEntry ::= SEQUENCE { pme1008CfgLinexr1StartupIndex INTEGER, pme1008CfgSystConfLinePortn Unsigned32, pme1008CfgOptionsLinePortn Unsigned32 } pme1008CfgLinexr1StartupIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the linexr1Startup table " ::= { pme1008CfgLinexr1StartupEntry 1 } pme1008CfgSystConfLinePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line :This register configures the default initialisation settings on Line " ::= { pme1008CfgLinexr1StartupEntry 3 } pme1008CfgOptionsLinePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Options on Line :This register configures the default options on the line " ::= { pme1008CfgLinexr1StartupEntry 14 } --- ***************************************************** --- LEAF for the table 2710 --- ***************************************************** pme1008CfgOtxtlhTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgStartup 3 } pme1008CfgOtxtlhEntry OBJECT-TYPE SYNTAX Pme1008CfgOtxtlhEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startup table " INDEX { pme1008CfgOtxtlhIndex } ::= { pme1008CfgOtxtlhTable 1 } Pme1008CfgOtxtlhEntry ::= SEQUENCE { pme1008CfgOtxtlhIndex INTEGER, pme1008CfgLineControlsPortn Unsigned32, pme1008CfgLinePwrLaserPortn Unsigned32, pme1008CfgLineFCurrentPortn Unsigned32, pme1008CfgLineGridCurrentPortn Unsigned32, pme1008CfgLineFoPortn Unsigned32 } pme1008CfgOtxtlhIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlh table " ::= { pme1008CfgOtxtlhEntry 1 } pme1008CfgLineControlsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Default Line settings :This register configures the start-up settings on the ports " ::= { pme1008CfgOtxtlhEntry 3 } pme1008CfgLinePwrLaserPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line output Power :This register configures the start-up output power of the client transceiver (Unit = dBm) " ::= { pme1008CfgOtxtlhEntry 6 } pme1008CfgLineFCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line transceiver Channel :This register configures the start-up laser channel of the client transceiver " ::= { pme1008CfgOtxtlhEntry 7 } pme1008CfgLineGridCurrentPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line transceiver Grid :This register configures the start-up laser grid of the client transceiver " ::= { pme1008CfgOtxtlhEntry 8 } pme1008CfgLineFoPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line first Frequency :This register configures the start-up first frequency of the client transceiver " ::= { pme1008CfgOtxtlhEntry 9 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pme1008CfgLabels OBJECT IDENTIFIER ::= { pme1008Config 2 } --- ***************************************************** --- LEAF for the table 0003 --- ***************************************************** pme1008CfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgLabels 1 } pme1008CfgLabelclientEntry OBJECT-TYPE SYNTAX Pme1008CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pme1008CfgLabelclientIndex } ::= { pme1008CfgLabelclientTable 1 } Pme1008CfgLabelclientEntry ::= SEQUENCE { pme1008CfgLabelclientIndex INTEGER, pme1008CfgLabelclientPortn DisplayString } pme1008CfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pme1008CfgLabelclientEntry 1 } pme1008CfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pme1008CfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table 0004 --- ***************************************************** pme1008CfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgLabels 2 } pme1008CfgLabellineEntry OBJECT-TYPE SYNTAX Pme1008CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pme1008CfgLabellineIndex } ::= { pme1008CfgLabellineTable 1 } Pme1008CfgLabellineEntry ::= SEQUENCE { pme1008CfgLabellineIndex INTEGER, pme1008CfgLabellinePortn DisplayString } pme1008CfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pme1008CfgLabellineEntry 1 } pme1008CfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pme1008CfgLabellineEntry 3 } --- ***************************************************** --- LEAF for the table Group other --- ***************************************************** pme1008CfgOther OBJECT IDENTIFIER ::= { pme1008Config 3 } --- ***************************************************** --- LEAF for the table 2300 --- ***************************************************** pme1008tablemoduleOther OBJECT IDENTIFIER ::= { pme1008CfgOther 1 } pme1008Cfgmode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on Module :This register selects the configuration mode of the module " ::= { pme1008tablemoduleOther 2 } --- ***************************************************** --- LEAF for the table Group odu2Clienta --- ***************************************************** pme1008CfgOdu2Clienta OBJECT IDENTIFIER ::= { pme1008Config 4 } --- ***************************************************** --- LEAF for the table 29C0 --- ***************************************************** pme1008CfgClientStartupOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientStartupOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgOdu2Clienta 1 } pme1008CfgClientStartupOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientStartupOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the odu2Clienta table " INDEX { pme1008CfgClientStartupOduIndex } ::= { pme1008CfgClientStartupOduTable 1 } Pme1008CfgClientStartupOduEntry ::= SEQUENCE { pme1008CfgClientStartupOduIndex INTEGER, pme1008CfgOdu2ReserveLsbPortn Unsigned32, pme1008CfgOdu2DegthresholdPortn Unsigned32, pme1008CfgOdu2DegmPortn Unsigned32, pme1008CfgOdu2SettingsPortn Unsigned32 } pme1008CfgClientStartupOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientStartupOdu table " ::= { pme1008CfgClientStartupOduEntry 1 } pme1008CfgOdu2ReserveLsbPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " : " ::= { pme1008CfgClientStartupOduEntry 3 } pme1008CfgOdu2DegthresholdPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Degrade Threshold : " ::= { pme1008CfgClientStartupOduEntry 4 } pme1008CfgOdu2DegmPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Degrade Confirmation : " ::= { pme1008CfgClientStartupOduEntry 5 } pme1008CfgOdu2SettingsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " ODU2 Settings : " ::= { pme1008CfgClientStartupOduEntry 6 } --- ***************************************************** --- LEAF for the table Group otu2Line --- ***************************************************** pme1008CfgOtu2Line OBJECT IDENTIFIER ::= { pme1008Config 5 } --- ***************************************************** --- LEAF for the table 29E0 --- ***************************************************** pme1008CfgLinexStartupOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLinexStartupOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgOtu2Line 1 } pme1008CfgLinexStartupOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLinexStartupOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the otu2Line table " INDEX { pme1008CfgLinexStartupOtuIndex } ::= { pme1008CfgLinexStartupOtuTable 1 } Pme1008CfgLinexStartupOtuEntry ::= SEQUENCE { pme1008CfgLinexStartupOtuIndex INTEGER, pme1008CfgOtu2ReserveMsbPortn Unsigned32, pme1008CfgOtu2DegthresholdPortn Unsigned32, pme1008CfgOtu2DegmPortn Unsigned32, pme1008CfgOtu2SettingsPortn Unsigned32 } pme1008CfgLinexStartupOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the linexStartupOtu table " ::= { pme1008CfgLinexStartupOtuEntry 1 } pme1008CfgOtu2ReserveMsbPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " : " ::= { pme1008CfgLinexStartupOtuEntry 3 } pme1008CfgOtu2DegthresholdPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Degrade Threshold : " ::= { pme1008CfgLinexStartupOtuEntry 4 } pme1008CfgOtu2DegmPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Degrade Confirmation : " ::= { pme1008CfgLinexStartupOtuEntry 5 } pme1008CfgOtu2SettingsPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " OTU2 Settings : " ::= { pme1008CfgLinexStartupOtuEntry 6 } --- ***************************************************** --- LEAF for the table Group sapiTxClient --- ***************************************************** pme1008CfgSapiTxClient OBJECT IDENTIFIER ::= { pme1008Config 6 } --- ***************************************************** --- LEAF for the table 2A10 --- ***************************************************** pme1008CfgClientSapiTxOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientSapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiTxClient 1 } pme1008CfgClientSapiTxOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientSapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiTxClient table " INDEX { pme1008CfgClientSapiTxOduIndex } ::= { pme1008CfgClientSapiTxOduTable 1 } Pme1008CfgClientSapiTxOduEntry ::= SEQUENCE { pme1008CfgClientSapiTxOduIndex INTEGER, pme1008CfgClientSapiTxSetupPortn DisplayString } pme1008CfgClientSapiTxOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiTxOdu table " ::= { pme1008CfgClientSapiTxOduEntry 1 } pme1008CfgClientSapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pme1008CfgClientSapiTxOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiExpClient --- ***************************************************** pme1008CfgSapiExpClient OBJECT IDENTIFIER ::= { pme1008Config 7 } --- ***************************************************** --- LEAF for the table 2A30 --- ***************************************************** pme1008CfgClientSapiExpOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientSapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiExpClient 1 } pme1008CfgClientSapiExpOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientSapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiExpClient table " INDEX { pme1008CfgClientSapiExpOduIndex } ::= { pme1008CfgClientSapiExpOduTable 1 } Pme1008CfgClientSapiExpOduEntry ::= SEQUENCE { pme1008CfgClientSapiExpOduIndex INTEGER, pme1008CfgClientSapiExpSetupPortn DisplayString } pme1008CfgClientSapiExpOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiExpOdu table " ::= { pme1008CfgClientSapiExpOduEntry 1 } pme1008CfgClientSapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Expected SAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pme1008CfgClientSapiExpOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiAccClient --- ***************************************************** pme1008CfgSapiAccClient OBJECT IDENTIFIER ::= { pme1008Config 8 } --- ***************************************************** --- LEAF for the table 2A50 --- ***************************************************** pme1008CfgClientSapiAccOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientSapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiAccClient 1 } pme1008CfgClientSapiAccOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientSapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiAccClient table " INDEX { pme1008CfgClientSapiAccOduIndex } ::= { pme1008CfgClientSapiAccOduTable 1 } Pme1008CfgClientSapiAccOduEntry ::= SEQUENCE { pme1008CfgClientSapiAccOduIndex INTEGER, pme1008CfgClientSapiAccSetupPortn DisplayString } pme1008CfgClientSapiAccOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientSapiAccOdu table " ::= { pme1008CfgClientSapiAccOduEntry 1 } pme1008CfgClientSapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Client Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pme1008CfgClientSapiAccOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiTxClient --- ***************************************************** pme1008CfgDapiTxClient OBJECT IDENTIFIER ::= { pme1008Config 9 } --- ***************************************************** --- LEAF for the table 2A90 --- ***************************************************** pme1008CfgClientDapiTxOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientDapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiTxClient 1 } pme1008CfgClientDapiTxOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientDapiTxOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiTxClient table " INDEX { pme1008CfgClientDapiTxOduIndex } ::= { pme1008CfgClientDapiTxOduTable 1 } Pme1008CfgClientDapiTxOduEntry ::= SEQUENCE { pme1008CfgClientDapiTxOduIndex INTEGER, pme1008CfgClientDapiTxSetupPortn DisplayString } pme1008CfgClientDapiTxOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiTxOdu table " ::= { pme1008CfgClientDapiTxOduEntry 1 } pme1008CfgClientDapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pme1008CfgClientDapiTxOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiExpClient --- ***************************************************** pme1008CfgDapiExpClient OBJECT IDENTIFIER ::= { pme1008Config 10 } --- ***************************************************** --- LEAF for the table 2AB0 --- ***************************************************** pme1008CfgClientDapiExpOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientDapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiExpClient 1 } pme1008CfgClientDapiExpOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientDapiExpOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiExpClient table " INDEX { pme1008CfgClientDapiExpOduIndex } ::= { pme1008CfgClientDapiExpOduTable 1 } Pme1008CfgClientDapiExpOduEntry ::= SEQUENCE { pme1008CfgClientDapiExpOduIndex INTEGER, pme1008CfgClientDapiExpSetupPortn DisplayString } pme1008CfgClientDapiExpOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiExpOdu table " ::= { pme1008CfgClientDapiExpOduEntry 1 } pme1008CfgClientDapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Client Expected DAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pme1008CfgClientDapiExpOduEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiAccClient --- ***************************************************** pme1008CfgDapiAccClient OBJECT IDENTIFIER ::= { pme1008Config 11 } --- ***************************************************** --- LEAF for the table 2AD0 --- ***************************************************** pme1008CfgClientDapiAccOduTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgClientDapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiAccClient 1 } pme1008CfgClientDapiAccOduEntry OBJECT-TYPE SYNTAX Pme1008CfgClientDapiAccOduEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiAccClient table " INDEX { pme1008CfgClientDapiAccOduIndex } ::= { pme1008CfgClientDapiAccOduTable 1 } Pme1008CfgClientDapiAccOduEntry ::= SEQUENCE { pme1008CfgClientDapiAccOduIndex INTEGER, pme1008CfgClientDapiAccSetupPortn DisplayString } pme1008CfgClientDapiAccOduIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the clientDapiAccOdu table " ::= { pme1008CfgClientDapiAccOduEntry 1 } pme1008CfgClientDapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Client Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pme1008CfgClientDapiAccOduEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiTxLine --- ***************************************************** pme1008CfgSapiTxLine OBJECT IDENTIFIER ::= { pme1008Config 12 } --- ***************************************************** --- LEAF for the table 2B10 --- ***************************************************** pme1008CfgLineSapiTxOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineSapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiTxLine 1 } pme1008CfgLineSapiTxOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineSapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiTxLine table " INDEX { pme1008CfgLineSapiTxOtuIndex } ::= { pme1008CfgLineSapiTxOtuTable 1 } Pme1008CfgLineSapiTxOtuEntry ::= SEQUENCE { pme1008CfgLineSapiTxOtuIndex INTEGER, pme1008CfgLineSapiTxSetupPortn DisplayString } pme1008CfgLineSapiTxOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiTxOtu table " ::= { pme1008CfgLineSapiTxOtuEntry 1 } pme1008CfgLineSapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Transmitted SAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pme1008CfgLineSapiTxOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiExpLine --- ***************************************************** pme1008CfgSapiExpLine OBJECT IDENTIFIER ::= { pme1008Config 13 } --- ***************************************************** --- LEAF for the table 2B30 --- ***************************************************** pme1008CfgLineSapiExpOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineSapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiExpLine 1 } pme1008CfgLineSapiExpOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineSapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiExpLine table " INDEX { pme1008CfgLineSapiExpOtuIndex } ::= { pme1008CfgLineSapiExpOtuTable 1 } Pme1008CfgLineSapiExpOtuEntry ::= SEQUENCE { pme1008CfgLineSapiExpOtuIndex INTEGER, pme1008CfgLineSapiExpSetupPortn DisplayString } pme1008CfgLineSapiExpOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiExpOtu table " ::= { pme1008CfgLineSapiExpOtuEntry 1 } pme1008CfgLineSapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Expected SAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pme1008CfgLineSapiExpOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group sapiAccLine --- ***************************************************** pme1008CfgSapiAccLine OBJECT IDENTIFIER ::= { pme1008Config 14 } --- ***************************************************** --- LEAF for the table 2B50 --- ***************************************************** pme1008CfgLineSapiAccOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineSapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgSapiAccLine 1 } pme1008CfgLineSapiAccOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineSapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the sapiAccLine table " INDEX { pme1008CfgLineSapiAccOtuIndex } ::= { pme1008CfgLineSapiAccOtuTable 1 } Pme1008CfgLineSapiAccOtuEntry ::= SEQUENCE { pme1008CfgLineSapiAccOtuIndex INTEGER, pme1008CfgLineSapiAccSetupPortn DisplayString } pme1008CfgLineSapiAccOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineSapiAccOtu table " ::= { pme1008CfgLineSapiAccOtuEntry 1 } pme1008CfgLineSapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Line Accepted SAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pme1008CfgLineSapiAccOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiTxLine --- ***************************************************** pme1008CfgDapiTxLine OBJECT IDENTIFIER ::= { pme1008Config 15 } --- ***************************************************** --- LEAF for the table 2B90 --- ***************************************************** pme1008CfgLineDapiTxOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineDapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiTxLine 1 } pme1008CfgLineDapiTxOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineDapiTxOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiTxLine table " INDEX { pme1008CfgLineDapiTxOtuIndex } ::= { pme1008CfgLineDapiTxOtuTable 1 } Pme1008CfgLineDapiTxOtuEntry ::= SEQUENCE { pme1008CfgLineDapiTxOtuIndex INTEGER, pme1008CfgLineDapiTxSetupPortn DisplayString } pme1008CfgLineDapiTxOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiTxOtu table " ::= { pme1008CfgLineDapiTxOtuEntry 1 } pme1008CfgLineDapiTxSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Transmitted DAPI :This register defines the value of the transmitted Trace Identifier on the line output " ::= { pme1008CfgLineDapiTxOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiExpLine --- ***************************************************** pme1008CfgDapiExpLine OBJECT IDENTIFIER ::= { pme1008Config 16 } --- ***************************************************** --- LEAF for the table 2BB0 --- ***************************************************** pme1008CfgLineDapiExpOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineDapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiExpLine 1 } pme1008CfgLineDapiExpOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineDapiExpOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiExpLine table " INDEX { pme1008CfgLineDapiExpOtuIndex } ::= { pme1008CfgLineDapiExpOtuTable 1 } Pme1008CfgLineDapiExpOtuEntry ::= SEQUENCE { pme1008CfgLineDapiExpOtuIndex INTEGER, pme1008CfgLineDapiExpSetupPortn DisplayString } pme1008CfgLineDapiExpOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiExpOtu table " ::= { pme1008CfgLineDapiExpOtuEntry 1 } pme1008CfgLineDapiExpSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Line Expected DAPI :This register defines the value of the expected Trace Identifier on the line input " ::= { pme1008CfgLineDapiExpOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group dapiAccLine --- ***************************************************** pme1008CfgDapiAccLine OBJECT IDENTIFIER ::= { pme1008Config 17 } --- ***************************************************** --- LEAF for the table 2BD0 --- ***************************************************** pme1008CfgLineDapiAccOtuTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgLineDapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgDapiAccLine 1 } pme1008CfgLineDapiAccOtuEntry OBJECT-TYPE SYNTAX Pme1008CfgLineDapiAccOtuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the dapiAccLine table " INDEX { pme1008CfgLineDapiAccOtuIndex } ::= { pme1008CfgLineDapiAccOtuTable 1 } Pme1008CfgLineDapiAccOtuEntry ::= SEQUENCE { pme1008CfgLineDapiAccOtuIndex INTEGER, pme1008CfgLineDapiAccSetupPortn DisplayString } pme1008CfgLineDapiAccOtuIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the lineDapiAccOtu table " ::= { pme1008CfgLineDapiAccOtuEntry 1 } pme1008CfgLineDapiAccSetupPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION " Line Accepted DAPI :This register defines the value of the accepted Trace Identifier on the line input " ::= { pme1008CfgLineDapiAccOtuEntry 3 } --- ***************************************************** --- LEAF for the table Group startuptablefive --- ***************************************************** pme1008CfgStartuptablefive OBJECT IDENTIFIER ::= { pme1008Config 18 } --- ***************************************************** --- LEAF for the table 0005 --- ***************************************************** pme1008CfgOtxtlhcapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF Pme1008CfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pme1008CfgStartuptablefive 1 } pme1008CfgOtxtlhcapabilitiesEntry OBJECT-TYPE SYNTAX Pme1008CfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startuptablefive table " INDEX { pme1008CfgOtxtlhcapabilitiesIndex } ::= { pme1008CfgOtxtlhcapabilitiesTable 1 } Pme1008CfgOtxtlhcapabilitiesEntry ::= SEQUENCE { pme1008CfgOtxtlhcapabilitiesIndex INTEGER, pme1008CfgComponentTypePortn Unsigned32, pme1008CfgMiscellaneousPortn Unsigned32, pme1008CfgFirstChannelPortn Unsigned32, pme1008CfgLastChannelPortn Unsigned32, pme1008CfgGridPortn Unsigned32 } pme1008CfgOtxtlhcapabilitiesIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlhcapabilities table " ::= { pme1008CfgOtxtlhcapabilitiesEntry 1 } pme1008CfgComponentTypePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Component parameters :This OID defines the component parameters " ::= { pme1008CfgOtxtlhcapabilitiesEntry 3 } pme1008CfgMiscellaneousPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Miscellaneous default settings :This OID defines the miscellaneous parameters " ::= { pme1008CfgOtxtlhcapabilitiesEntry 4 } pme1008CfgFirstChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the first channel of the component :This OID defines the first channel number of the PM " ::= { pme1008CfgOtxtlhcapabilitiesEntry 5 } pme1008CfgLastChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the last channel of the component :This OID defines the last channel number of the PM " ::= { pme1008CfgOtxtlhcapabilitiesEntry 6 } pme1008CfgGridPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Grid value of the component :This OID defines the grid of the PM " ::= { pme1008CfgOtxtlhcapabilitiesEntry 7 } pme1008CfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pme1008Config 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pme1008trapPortNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last port which generates a trap" ::= { pme1008traps 2 } pme1008trapLineNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last Line which generates a trap" ::= { pme1008traps 3 } pme1008trapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pme1008traps 4 } --- ***************************************************** --- LINE TRAPS --- ***************************************************** pme1008LineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmLineDdmWarningPortn, pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pme1008AlmLineDdmWarningPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Warning appears on Line Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pme1008traps 30 } pme1008LineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmLineDdmWarningPortn, pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Line Not Urgent ON" } --&MATCH { pme1008AlmLineDdmWarningPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Warning disappears on Line Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pme1008traps 31 } pme1008LineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmLineDdmAlmPortn, pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pme1008AlmLineDdmAlmPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Alarm appears on Line Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pme1008traps 32 } pme1008LineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmLineDdmAlmPortn, pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Line Urgent ON" } --&MATCH { pme1008AlmLineDdmAlmPortn "on", pme1008trapLineNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Alarm disappears on Line Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pme1008traps 33 } pme1008LineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmLineFailPortn , pme1008AlmLineHwFailPortn , pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pme1008AlmLineFailPortn "on", pme1008AlmLineHwFailPortn "*", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Line Port $3 Down on PME1008 in Slot $4 ($A)" --&FILTNAME "PME1008 Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pme1008AlmLineFailPortn "*", pme1008AlmLineHwFailPortn "on", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Line Port $3 Down on PME1008 in Slot $4 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pme1008traps 34 } pme1008LineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmLineFailPortn , pme1008AlmLineHwFailPortn , pme1008trapLineNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Line Fail ON" } --&MATCH { pme1008AlmLineFailPortn "on", pme1008AlmLineHwFailPortn "*", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Line Port $3 Up on PME1008 in Slot $4 ($A)" --&FILTNAME "PME1008 Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pme1008AlmLineFailPortn "*", pme1008AlmLineHwFailPortn "on", pme1008trapLineNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Line Port $3 Up on PME1008 in Slot $4 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pme1008traps 35 } --- ***************************************************** --- CLIENT TRAPS --- ***************************************************** pme1008ClientTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmSfpDdmWarningPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pme1008AlmSfpDdmWarningPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Warning appears on Client Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pme1008traps 40 } pme1008ClientTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmSfpDdmWarningPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Client Not Urgent ON" } --&MATCH { pme1008AlmSfpDdmWarningPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Warning appears on Client Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pme1008traps 41 } pme1008ClientTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmSfpDdmAlmPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Urgent ON" --&ACTIONS { log, major } --&MATCH { pme1008AlmSfpDdmAlmPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Alarm appears on Client Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pme1008traps 42 } pme1008ClientTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmSfpDdmAlmPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Client Urgent ON" } --&MATCH { pme1008AlmSfpDdmAlmPortn "on", pme1008trapPortNumber "$2", pme1008trapBoardNumber "$3"} --&MESG "DDM Alarm disappears on Client Port $2 of PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pme1008traps 43 } pme1008ClientTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmFailAccPortn, pme1008AlmHwFailAccPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Fail ON" --&ACTIONS { log, critical } --&MATCH { pme1008AlmFailAccPortn "on", pme1008AlmHwFailAccPortn "*", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Client Port $3 Down on PME1008 in Slot $4 ($A)" --&FILTNAME "PME1008 Client HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pme1008AlmFailAccPortn "*", pme1008AlmHwFailAccPortn "on", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Client Port $3 Down on PME1008 in Slot $4 ($A)" DESCRIPTION "Critical client default is activated" ::= { pme1008traps 44 } pme1008ClientTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmFailAccPortn, pme1008AlmHwFailAccPortn, pme1008trapPortNumber, pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Client Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PME1008 Client Fail ON" } --&MATCH { pme1008AlmFailAccPortn "on", pme1008AlmHwFailAccPortn "*", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Client Port $3 Up on PME1008 in Slot $4 ($A)" --&FILTNAME "PME1008 Client HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pme1008AlmFailAccPortn "*", pme1008AlmHwFailAccPortn "on", pme1008trapPortNumber "$3", pme1008trapBoardNumber "$4"} --&MESG "Client Port $3 Up on PME1008 in Slot $4 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pme1008traps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pme1008PowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pme1008AlmDefFuseB, pme1008AlmDefFuseA , pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pme1008AlmDefFuseB "*", pme1008AlmDefFuseA "on", pme1008trapBoardNumber "$3"} --&MESG "Power Input A Fail on PME1008 in Slot $3 ($A)" --&FILTNAME "PME1008 Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pme1008AlmDefFuseB "on", pme1008AlmDefFuseA "*", pme1008trapBoardNumber "$3"} --&MESG "Power Input B Fail on PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pme1008traps 50 } pme1008PowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pme1008AlmDefFuseB, pme1008AlmDefFuseA , pme1008trapBoardNumber} STATUS current --&FILTNAME "PME1008 Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PME1008 Fuse A Fail ON", "PME1008 Fuse B Fail ON" } --&MATCH { pme1008AlmDefFuseB "on", pme1008AlmDefFuseA "on", pme1008trapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PME1008 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pme1008traps 51 } END