-- ***************************************************************** -- EKINOPS-Pmpump3.TXT: MIB -- --MIB Part Number:3MI00207ABAD --MIB Version:01 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-PmPump3-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulepmpump3 MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "Creation" REVISION "201009010000Z" DESCRIPTION "Creation" REVISION "201012150000Z" DESCRIPTION "Add inventory of the lasers" REVISION "201109200000Z" DESCRIPTION "OOS insertion" REVISION "201207040000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403260000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201411250000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 49 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmpump3alarms OBJECT IDENTIFIER ::= { modulepmpump3 2 } pmpump3AlmOther OBJECT IDENTIFIER ::= { pmpump3alarms 1 } pmpump3AlmOtherNurg OBJECT IDENTIFIER ::= { pmpump3AlmOther 1 } pmpump3AlmOtherUrg OBJECT IDENTIFIER ::= { pmpump3AlmOther 2 } pmpump3AlmOtherCrit OBJECT IDENTIFIER ::= { pmpump3AlmOther 3 } pmpump3AlmClient OBJECT IDENTIFIER ::= { pmpump3alarms 2 } pmpump3AlmClientNurg OBJECT IDENTIFIER ::= { pmpump3AlmClient 1 } pmpump3AlmClientUrg OBJECT IDENTIFIER ::= { pmpump3AlmClient 2 } pmpump3AlmClientCrit OBJECT IDENTIFIER ::= { pmpump3AlmClient 3 } pmpump3AlmLine OBJECT IDENTIFIER ::= { pmpump3alarms 3 } pmpump3AlmLineNurg OBJECT IDENTIFIER ::= { pmpump3AlmLine 1 } pmpump3AlmLineUrg OBJECT IDENTIFIER ::= { pmpump3AlmLine 2 } pmpump3AlmLineCrit OBJECT IDENTIFIER ::= { pmpump3AlmLine 3 } pmpump3measures OBJECT IDENTIFIER ::= { modulepmpump3 3 } pmpump3MesrOther OBJECT IDENTIFIER ::= { pmpump3measures 1 } pmpump3MesrClient OBJECT IDENTIFIER ::= { pmpump3measures 2 } pmpump3MesrLine OBJECT IDENTIFIER ::= { pmpump3measures 3 } pmpump3controlsWrite OBJECT IDENTIFIER ::= { modulepmpump3 6 } pmpump3CtrlOther OBJECT IDENTIFIER ::= { pmpump3controlsWrite 1 } pmpump3CtrlClient OBJECT IDENTIFIER ::= { pmpump3controlsWrite 2 } pmpump3CtrlLine OBJECT IDENTIFIER ::= { pmpump3controlsWrite 3 } pmpump3ri OBJECT IDENTIFIER ::= { modulepmpump3 7 } pmpump3riTable OBJECT IDENTIFIER ::= { pmpump3ri 1 } pmpump3Config OBJECT IDENTIFIER ::= { modulepmpump3 9 } pmpump3traps OBJECT IDENTIFIER ::= { modulepmpump3 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmpump3RinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmpump3ri 2 } pmpump3RinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "HW platform description: This OID contains the description of the Hardware platform." ::= { pmpump3ri 3 } pmpump3RinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmpump3ri 4 } pmpump3RinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmpump3ri 5 } pmpump3RinvLaser1Table OBJECT-TYPE SYNTAX SEQUENCE OF Pmpump3RinvLaser1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the lasers on the selected module" ::= { pmpump3riTable 1 } pmpump3RinvLaser1Entry OBJECT-TYPE SYNTAX Pmpump3RinvLaser1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the laser table" INDEX { pmpump3RinvLaser1Index } ::= { pmpump3RinvLaser1Table 1 } Pmpump3RinvLaser1Entry::= SEQUENCE { pmpump3RinvLaser1Index Integer32, pmpump3RinvLaser1 DisplayString } pmpump3RinvLaser1Index OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for laser table" ::= { pmpump3RinvLaser1Entry 1 } pmpump3RinvLaser1 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the laser: This OID contains the inventory for the laser" ::= { pmpump3RinvLaser1Entry 2 } pmpump3RinvLaser2Table OBJECT-TYPE SYNTAX SEQUENCE OF Pmpump3RinvLaser2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the lasers on the selected module" ::= { pmpump3riTable 2 } pmpump3RinvLaser2Entry OBJECT-TYPE SYNTAX Pmpump3RinvLaser2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the laser table" INDEX { pmpump3RinvLaser2Index } ::= { pmpump3RinvLaser2Table 1 } Pmpump3RinvLaser2Entry::= SEQUENCE { pmpump3RinvLaser2Index Integer32, pmpump3RinvLaser2 DisplayString } pmpump3RinvLaser2Index OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for laser table" ::= { pmpump3RinvLaser2Entry 1 } pmpump3RinvLaser2 OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the laser: This OID contains the inventory for the laser" ::= { pmpump3RinvLaser2Entry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmpump3AlmsynthAlm0 OBJECT IDENTIFIER ::= { pmpump3AlmOtherCrit 0 } pmpump3AlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmpump3AlmsynthAlm0 16 } pmpump3AlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmpump3AlmsynthAlm0 15 } pmpump3AlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MOD_GLOB_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmpump3AlmsynthAlm2 OBJECT IDENTIFIER ::= { pmpump3AlmOtherNurg 2 } pmpump3AlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD other (1) other (1) (2) " ::= { pmpump3AlmsynthAlm2 3 } pmpump3AlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD other (1) other (1) (2) " ::= { pmpump3AlmsynthAlm2 2 } pmpump3AlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE other (1) other (1) (2) " ::= { pmpump3AlmsynthAlm2 1 } --- ***************************************************** --- LEAF for the synthAlmLaser1 article --- ***************************************************** pmpump3AlmsynthAlmLaser1 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 8 } pmpump3AlmLaser1Fail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Failure :This OID indicates a failure on the pump LASER1_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser1 12 } pmpump3AlmLaser1Alm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Booster / IL1 Pump DDM :This OID indicates an alarm is present coming out of the IL1 pump DDM LASER1_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser1 10 } pmpump3AlmLaser1Warning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Booster / IL1 Pump DDM :This OID indicates a warning is present coming out of IL1 pump DDM LASER1_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser1 9 } pmpump3AlmLaser1Oos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump In Service :This OID indicates that the IL1 pump is In Service (1) of Out or Service (2) This status indicates if the IL1 pump is in service LASER1_OOS other (1) other (1) (2) " ::= { pmpump3AlmsynthAlmLaser1 6 } pmpump3AlmLaser1TxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Output Shutdown :This OID indicates the IL1 pump optical output power is on. This status indicates if the IL1 laser pump is ON or OFF LASER1_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmpump3AlmsynthAlmLaser1 5 } pmpump3AlmLaser1HwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump HW Failure :This OID indicates a failure on IL1 pump, most probably caused by a HW issue LASER1_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser1 4 } pmpump3AlmLaser1InitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Not Ready :This OID indicates that the IL1 pump is not operational. LASER1_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmpump3AlmsynthAlmLaser1 2 } --- ***************************************************** --- LEAF for the synthAlmLaser2 article --- ***************************************************** pmpump3AlmsynthAlmLaser2 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 9 } pmpump3AlmLaser2Fail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Failure :This OID indicates a failure on the pump LASER2_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser2 12 } pmpump3AlmLaser2Alm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Pre-Amp / IL2 Pump DDM :This OID indicates an alarm is present coming out of IL2 pump DDM LASER2_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser2 10 } pmpump3AlmLaser2Warning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Pre-Amp / IL2 Pump DDM :This OID indicates a warning is present coming out of the IL2 pump DDM LASER2_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser2 9 } pmpump3AlmLaser2Oos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump In Service :This OID indicates that the IL2 pump is In Service (1) of Out or Service (2) This status indicates if the IL2 pump is in service LASER2_OOS other (1) other (1) (2) " ::= { pmpump3AlmsynthAlmLaser2 6 } pmpump3AlmLaser2TxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Output Shutdown :This OID indicates the IL2 pump optical output power is on. This status indicates if the IL2 laser pump is ON or OFF LASER2_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmpump3AlmsynthAlmLaser2 5 } pmpump3AlmLaser2HwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump HW Failure :This OID indicates a failure on IL2 pump, most probably caused by a HW issue LASER2_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmpump3AlmsynthAlmLaser2 4 } pmpump3AlmLaser2InitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Not Ready :This OID indicates that the IL2 pump is not operational. LASER2_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmpump3AlmsynthAlmLaser2 2 } --- ***************************************************** --- LEAF for the laser1Alarms1 article --- ***************************************************** pmpump3Almlaser1Alarms1 OBJECT IDENTIFIER ::= { pmpump3AlmClientUrg 16 } pmpump3AlmLaser1BiasHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL1 pump. This alarm indicates if the IL2 bias is too high LASER1_BIAS_HIGH_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 8 } pmpump3AlmLaser1BiasLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL1 pump. This alarm indicates if the IL2 bias is too low LASER1_BIAS_LOW_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 7 } pmpump3AlmLaser1OutputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 power is too high LASER1_OUTPUT_PWR_HIGH_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 6 } pmpump3AlmLaser1OutputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 power is too low LASER1_OUTPUT_PWR_LOW_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 5 } pmpump3AlmLaser1VthHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Vth High Alarm :This OID indicates that the thermistor voltage is higher than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 power is too high LASER1_VTH_HIGH_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 4 } pmpump3AlmLaser1VthLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Vth Low Alarm :This OID indicates that the thermistor voltage is lower than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 power is too low LASER1_VTH_LOW_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 3 } pmpump3AlmLaser1TempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Temp High Alarm :This OID indicates that the pump temperature is higher than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 pump temperature is too high LASER1_TEMP_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 2 } pmpump3AlmLaser1TempLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Temp Low Alarm :This OID indicates that the pump temperature is lower than the alarm threshold of the IL1 pump. This alarm indicates if the IL1 pump temperature is too low LASER1_TEMP_LOW_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms1 1 } --- ***************************************************** --- LEAF for the laser1Warnings article --- ***************************************************** pmpump3Almlaser1Warnings OBJECT IDENTIFIER ::= { pmpump3AlmClientNurg 17 } pmpump3AlmLaser1BiasHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Bias High Warning :This OID indicates that the Bias is higher than the warning threshold of the IL1 pump. This warning indicates if the IL1 bias is too high LASER1_BIAS_HIGH_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 8 } pmpump3AlmLaser1BiasLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Bias Low Warning :This OID indicates that the Bias is lower than the warning threshold of the IL1 pump. This warning indicates if the IL1 bias is too low LASER1_BIAS_LOW_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 7 } pmpump3AlmLaser1OutputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pwr High Warning :This OID indicates that the Transmit Power is higher than the warning threshold of the IL1 pump. This warning indicates if the IL1 power is too high LASER1_OUTPUT_PWR_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 6 } pmpump3AlmLaser1OutputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pwr Low Warning :This OID indicates that the Transmit Power is lower than the warning threshold of the IL1 pump. This warning indicates if the IL1 power is too low LASER1_OUTPUT_PWR_LOW_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 5 } pmpump3AlmLaser1VthHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Vth High Warning :This OID indicates that the thermistor voltage is higher than the warning threshold of the IL1 pump. This warning indicates if the IL1 power is too high LASER1_VTH_HIGH_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 4 } pmpump3AlmLaser1VthLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Vth Low Warning :This OID indicates that the thermistor voltage is lower than the warning threshold of the IL1 pump. This warning indicates if the IL1 power is too low LASER1_VTH_LOW_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 3 } pmpump3AlmLaser1TempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Temp High Warning :This OID indicates that the pump temperature is higher than the warning threshold of the IL1 pump. This warning indicates if the IL1 pump temperature is too high LASER1_TEMP_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 2 } pmpump3AlmLaser1TempLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Temp Low Warning :This OID indicates that the pump temperature is lower than the warning threshold of the IL1 pump. This warning indicates if the IL1 pump temperature is too low LASER1_TEMP_LOW_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Warnings 1 } --- ***************************************************** --- LEAF for the laser1Alarms2 article --- ***************************************************** pmpump3Almlaser1Alarms2 OBJECT IDENTIFIER ::= { pmpump3AlmClientCrit 19 } pmpump3AlmLaser1ExtLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Laser Shutdown :This OID indicates that the laser of the pump is shut down This status indicates that the laser of the pump is shut down LASER1_EXT_LSD other (1) other (1) (2) " ::= { pmpump3Almlaser1Alarms2 6 } pmpump3AlmLaser1OaDisconnectedLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Link Disconnected :This OID indicates that the link betwenn the amplifier and the pump is open This alarm indicates that the OA or the fiber is not present LASER1_OA_DISCONNECTED_LSD other (1) other (1) (2) " ::= { pmpump3Almlaser1Alarms2 5 } pmpump3AlmLaser1AlmTecDev OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 TEC Deviation :This OID indicates that the loop control of the TEC is in fail condition This alarm indicates if the loop control of the TEC is in fail condition LASER1_ALM_TEC_DEV receiveFailure (41) physicalViolation (9) (2) " ::= { pmpump3Almlaser1Alarms2 4 } pmpump3AlmLaser1AlmTecPower OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 TEC Pw :This OID indicates that the TEC power supply is in fail condition . This alarm indicates if the TEC power is in fail condition LASER1_ALM_TEC_POWER pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms2 3 } pmpump3AlmLaser1AlmTemp OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Temperature Alarm :This OID indicates that the temperature of the current driver has reached the internal limitation. This alarm indicates if the temperature has reached its limitation LASER1_ALM_TEMP pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms2 2 } pmpump3AlmLaser1AlmCurrent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Current Alarm :This OID indicates that maximum current has reached the internal limitation This alarm indicates if the current has reached its limitation LASER1_ALM_CURRENT equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser1Alarms2 1 } --- ***************************************************** --- LEAF for the laser2Alarms1 article --- ***************************************************** pmpump3Almlaser2Alarms1 OBJECT IDENTIFIER ::= { pmpump3AlmLineUrg 24 } pmpump3AlmLaser2BiasHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Bias High Alarm :This OID indicates that the Bias is higher than the alarm threshold of the IL1 Optical Module This alarm indicates if the IL2 bias is too high LASER2_BIAS_HIGH_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 8 } pmpump3AlmLaser2BiasLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Bias Low Alarm :This OID indicates that the Bias is lower than the alarm threshold of the IL1 Optical Module This alarm indicates if the IL2 bias is too low LASER2_BIAS_LOW_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 7 } pmpump3AlmLaser2OutputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm threshold of the IL1 Optical Module This alarm indicates if the IL2 power is too high LASER2_OUTPUT_PWR_HIGH_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 6 } pmpump3AlmLaser2OutputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm threshold of the IL1 Optical Module This alarm indicates if the IL2 power is too low LASER2_OUTPUT_PWR_LOW_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 5 } pmpump3AlmLaser2VthHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Vth High Alarm :This OID indicates that the Receive Power is higher than the alarm threshold of the IL2 Optical Module This alarm indicates if the IL2 power is too high LASER2_VTH_HIGH_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 4 } pmpump3AlmLaser2VthLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Vth Low Alarm :This OID indicates that the Receive Power is lower than the alarm threshold of the IL2 Optical Module This alarm indicates if the IL2 power is too low LASER2_VTH_LOW_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 3 } pmpump3AlmLaser2TempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Temp High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the IL1 Module This alarm indicates if the IL2 pump temperature is too high LASER2_TEMP_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 2 } pmpump3AlmLaser2TempLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Temp Low Alarm :This OID indicates that the Gain is lower than the alarm threshold of the IL1 Module This alarm indicates if the IL2 pump temperature is too low LASER2_TEMP_LOW_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms1 1 } --- ***************************************************** --- LEAF for the laser2Warnings article --- ***************************************************** pmpump3Almlaser2Warnings OBJECT IDENTIFIER ::= { pmpump3AlmLineNurg 25 } pmpump3AlmLaser2BiasHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Bias High Warning :This OID indicates that the Bias is higher than the Warning threshold of the IL1 Optical Module This warning indicates if the IL2 bias is too high LASER2_BIAS_HIGH_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 8 } pmpump3AlmLaser2BiasLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Bias Low Warning :This OID indicates that the Bias is lower than the Warning threshold of the IL1 Optical Module This warning indicates if the IL2 bias is too low LASER2_BIAS_LOW_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 7 } pmpump3AlmLaser2OutputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning threshold of the IL1 Optical Module This warning indicates if the IL2 power is too high LASER2_OUTPUT_PWR_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 6 } pmpump3AlmLaser2OutputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning threshold of the IL1 Optical Module This warning indicates if the IL2 power is too low LASER2_OUTPUT_PWR_LOW_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 5 } pmpump3AlmLaser2VthHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Vth High Warning :This OID indicates that the Receive Power is higher than the Warning threshold of the IL2 Optical Module This warning indicates if the IL2 power is too high LASER2_VTH_HIGH_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 4 } pmpump3AlmLaser2VthLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Vth Low Warning :This OID indicates that the Receive Power is lower than the Warning threshold of the IL2 Optical Module This warning indicates if the IL2 power is too low LASER2_VTH_LOW_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 3 } pmpump3AlmLaser2TempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Temp High Warning :This OID indicates that the Gain is higher than the Warning threshold of the IL1 Module This warning indicates if the IL2 pump temperature is too high LASER2_TEMP_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 2 } pmpump3AlmLaser2TempLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Temp Low Warning :This OID indicates that the Gain is lower than the Warning threshold of the IL1 Module This warning indicates if the IL2 pump temperature is too low LASER2_TEMP_LOW_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Warnings 1 } --- ***************************************************** --- LEAF for the laser2Alarms2 article --- ***************************************************** pmpump3Almlaser2Alarms2 OBJECT IDENTIFIER ::= { pmpump3AlmLineCrit 27 } pmpump3AlmLaser2ExtLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Laser Shutdown :This OID indicates that the laser of the pump is shut down This status indicates that the laser of the pump is shut down LASER2_EXT_LSD other (1) other (1) (2) " ::= { pmpump3Almlaser2Alarms2 6 } pmpump3AlmLaser2OaDisconnectedLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Link Disconnected :This OID indicates that the link betwenn the amplifier and the pump is open This alarm indicates that the OA or the fiber is not present LASER2_OA_DISCONNECTED_LSD other (1) other (1) (2) " ::= { pmpump3Almlaser2Alarms2 5 } pmpump3AlmLaser2AlmTecDev OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 TEC Deviation :This OID indicates that the loop control of the TEC is in fail condition This alarm indicates if the loop control of the TEC is in fail condition LASER2_ALM_TEC_DEV receiveFailure (41) physicalViolation (9) (2) " ::= { pmpump3Almlaser2Alarms2 4 } pmpump3AlmLaser2AlmTecPower OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 TEC Pw :This OID indicates that the TEC power supply is in fail condition . This alarm indicates if the TEC power is in fail condition LASER2_ALM_TEC_POWER pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms2 3 } pmpump3AlmLaser2AlmTemp OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Temperature Alarm :This OID indicates that the temperature of the current driver has reached the internal limitation. This alarm indicates if the temperature has reached its limitation LASER2_ALM_TEMP pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms2 2 } pmpump3AlmLaser2AlmCurrent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Current Alarm :This OID indicates that maximum current has reached the internal limitation This alarm indicates if the current has reached its limitation LASER2_ALM_CURRENT equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmpump3Almlaser2Alarms2 1 } --- ***************************************************** --- LEAF for the pmAlarms article --- ***************************************************** pmpump3AlmpmAlarms OBJECT IDENTIFIER ::= { pmpump3AlmOtherUrg 74 } pmpump3AlmTempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold This alarm indicates if the module temperature is too high TEMP_HIGH_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmpump3AlmpmAlarms 2 } pmpump3AlmTermpLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold This alarm indicates if the module temperature is too low TERMP_LOW_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmpump3AlmpmAlarms 1 } --- ***************************************************** --- LEAF for the pmWarnings article --- ***************************************************** pmpump3AlmpmWarnings OBJECT IDENTIFIER ::= { pmpump3AlmOtherNurg 75 } pmpump3AlmTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold This warning indicates if the module temperature is too high TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmpump3AlmpmWarnings 2 } pmpump3AlmTermpLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold This warning indicates if the module temperature is too low TERMP_LOW_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmpump3AlmpmWarnings 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmpump3Ctrlsynth0 OBJECT IDENTIFIER ::= { pmpump3CtrlOther 0 } pmpump3CtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmpump3Ctrlsynth0 13 } pmpump3CtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmpump3Ctrlsynth0 9 } pmpump3CtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmpump3Ctrlsynth0 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmpump3CtrlswMgnt OBJECT IDENTIFIER ::= { pmpump3CtrlOther 5 } pmpump3CtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmpump3CtrlswMgnt 3 } pmpump3CtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmpump3CtrlswMgnt 2 } --- ***************************************************** --- LEAF for the laser1LaserOff article --- ***************************************************** pmpump3Ctrllaser1LaserOff OBJECT IDENTIFIER ::= { pmpump3CtrlClient 32 } pmpump3CtrlLaser1LaserOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Booster / IL1 Pump Laser Off :This OID switches OFF the laser of the IL1 pump. This control defines the laser state of the IL1 " ::= { pmpump3Ctrllaser1LaserOff 1 } --- ***************************************************** --- LEAF for the laser1EffPwrOutSettingValue article --- ***************************************************** pmpump3Ctrllaser1EffPwrOutSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster / IL1 Effective Output Power :This OID sets the value of the effective output power of the IL1 pump (Unit = dBm) This control defines the IL1 effective output power in dBm. " ::= { pmpump3CtrlClient 37 } --- ***************************************************** --- LEAF for the laser2LaserOff article --- ***************************************************** pmpump3Ctrllaser2LaserOff OBJECT IDENTIFIER ::= { pmpump3CtrlLine 40 } pmpump3CtrlLaser2LaserOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Preampli / IL2 Pump Laser Off :This OID switches OFF the laser of the IL2 pump. This control defines the laser state of the IL2 " ::= { pmpump3Ctrllaser2LaserOff 1 } --- ***************************************************** --- LEAF for the laser2EffPwrOutSettingValue article --- ***************************************************** pmpump3Ctrllaser2EffPwrOutSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Preampli / IL2 Effective Output Power :This OID sets the value of the effective output power of the IL2 pump (Unit = dBm) This control defines the IL2 effective output power in dBm. " ::= { pmpump3CtrlLine 45 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmpump3CtrlledTest OBJECT IDENTIFIER ::= { pmpump3CtrlOther 73 } pmpump3CtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmpump3CtrlledTest 3 } pmpump3CtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmpump3CtrlledTest 2 } pmpump3CtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmpump3CtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the laser1BiasMeas article --- ***************************************************** pmpump3Mesrlaser1BiasMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Laser Bias :This OID gives the pump laser current of the IL1 laser (Bias = AV/20) (Unit = mA) This measure gives the bias of the IL1 pump laser " ::= { pmpump3MesrClient 16 } --- ***************************************************** --- LEAF for the laser1VthMeas article --- ***************************************************** pmpump3Mesrlaser1VthMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Temp. Reg. Volt :This OID gives the Voltage of the Temperature Regulator of the IL1 laser (Voltage = AV/10000) (Unit = V) This measure gives the Voltage of the Temperature Regulator of the IL1 pump laser " ::= { pmpump3MesrClient 17 } --- ***************************************************** --- LEAF for the laser2BiasMeas article --- ***************************************************** pmpump3Mesrlaser2BiasMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Laser Bias :This OID gives the pump laser current of the IL2 laser (Bias = AV/20) (Unit = mA) This measure gives the bias of the IL2 pump laser " ::= { pmpump3MesrLine 24 } --- ***************************************************** --- LEAF for the laser2VthMeas article --- ***************************************************** pmpump3Mesrlaser2VthMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Temp. Reg. Volt :This OID gives the Voltage of the Temperature Regulator of the IL2 laser (Voltage = AV/10000) (Unit = V) This measure gives the Voltage of the Temperature Regulator of the IL2 pump laser " ::= { pmpump3MesrLine 25 } --- ***************************************************** --- LEAF for the laser1Pwr article --- ***************************************************** pmpump3Mesrlaser1Pwr OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Power :This OID gives the power value provided by the external pump to the IL1 (Power = AV/20) (Unit = mW) This measure gives the power provided by the pump to the IL1 " ::= { pmpump3MesrClient 36 } --- ***************************************************** --- LEAF for the laser1Temp article --- ***************************************************** pmpump3Mesrlaser1Temp OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster / IL1 Pump Temperature :This OID gives the temperature value of the pump linked to the IL1 (Temperature = AV/256) (Unit = C) This measure gives the temperature value of the pump linked to the IL1 " ::= { pmpump3MesrClient 37 } --- ***************************************************** --- LEAF for the laser2Pwr article --- ***************************************************** pmpump3Mesrlaser2Pwr OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Power : This OID gives the power value provided by the external pump to the IL2 (Power = AV/20) (Unit = mW) This measure gives the power provided by the pump to the IL2 " ::= { pmpump3MesrLine 44 } --- ***************************************************** --- LEAF for the laser2Temp article --- ***************************************************** pmpump3Mesrlaser2Temp OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp / IL2 Pump Temperature :This OID gives the temperature value of the pump linked to the IL2 (Temperature = AV/256) (Unit = C) This measure gives the temperature value of the pump linked to the IL2 " ::= { pmpump3MesrLine 45 } --- ***************************************************** --- LEAF for the tempMeas article --- ***************************************************** pmpump3MesrtempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature :This OID gives the temperature of the PM (Temperature = AV/256) (Unit = C) This measure gives the temperature of the module " ::= { pmpump3MesrOther 74 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group noValue --- ***************************************************** pmpump3CfgNoValue OBJECT IDENTIFIER ::= { pmpump3Config 1 } --- ***************************************************** --- LEAF for the table 2111 --- ***************************************************** pmpump3tableclientStartup OBJECT IDENTIFIER ::= { pmpump3CfgNoValue 1 } pmpump3Cfglaser1Ctrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on IL1 pump Laser :This OID configures the default initialisation settings on the IL1 pump laser. " ::= { pmpump3tableclientStartup 2 } --- ***************************************************** --- LEAF for the table Group lineStartUp --- ***************************************************** pmpump3CfgLineStartUp OBJECT IDENTIFIER ::= { pmpump3Config 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pmpump3tablelineStartup OBJECT IDENTIFIER ::= { pmpump3CfgLineStartUp 1 } pmpump3Cfglaser2Ctrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on IL2 pump Laser :This OID configures the default initialisation settings on the IL2 pump laser. " ::= { pmpump3tablelineStartup 2 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmpump3CfgLabels OBJECT IDENTIFIER ::= { pmpump3Config 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmpump3CfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmpump3CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmpump3CfgLabels 1 } pmpump3CfgLabelclientEntry OBJECT-TYPE SYNTAX Pmpump3CfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmpump3CfgLabelclientIndex } ::= { pmpump3CfgLabelclientTable 1 } Pmpump3CfgLabelclientEntry ::= SEQUENCE { pmpump3CfgLabelclientIndex INTEGER, pmpump3CfgLabelclientPortn DisplayString } pmpump3CfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmpump3CfgLabelclientEntry 1 } pmpump3CfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmpump3CfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmpump3CfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pmpump3CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmpump3CfgLabels 2 } pmpump3CfgLabellineEntry OBJECT-TYPE SYNTAX Pmpump3CfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmpump3CfgLabellineIndex } ::= { pmpump3CfgLabellineTable 1 } Pmpump3CfgLabellineEntry ::= SEQUENCE { pmpump3CfgLabellineIndex INTEGER, pmpump3CfgLabellinePortn DisplayString } pmpump3CfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmpump3CfgLabellineEntry 1 } pmpump3CfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmpump3CfgLabellineEntry 3 } pmpump3CfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmpump3Config 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmpump3trapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmpump3traps 4 } --- ***************************************************** --- GLOBAL TRAPS --- ***************************************************** pmpump3Laser2TrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Warning, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmpump3AlmLaser2Warning "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Warning appears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pmpump3traps 30 } pmpump3Laser2TrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Warning, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Not Urgent ON"} --&MATCH { pmpump3AlmLaser2Warning "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Warning disappears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pmpump3traps 31 } pmpump3Laser2TrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Alm, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Urgent ON" --&ACTIONS { log, major } --&MATCH { pmpump3AlmLaser2Alm "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Alarms appears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pmpump3traps 32 } pmpump3Laser2TrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Alm, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Urgent ON"} --&MATCH { pmpump3AlmLaser2Alm "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Pre-Amp/IL2 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pmpump3traps 33 } pmpump3Laser2TrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Fail, pmpump3AlmLaser2HwFail, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Fail ON" --&ACTIONS { log, critical } --&MATCH { pmpump3AlmLaser2Fail "on", pmpump3AlmLaser2HwFail "*", pmpump3trapBoardNumber "$3"} --&MESG "Pre-Amp/IL2 Pump Down on PM PUMP3 in Slot $3 ($A)" --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmpump3AlmLaser2Fail "*", pmpump3AlmLaser2HwFail "on", pmpump3trapBoardNumber "$3"} --&MESG "Pre-Amp/IL2 Pump Down on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmpump3traps 34 } pmpump3Laser2TrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser2Fail, pmpump3AlmLaser2HwFail, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Pre-Amp/IL2 Pump Fail ON" } --&MATCH { pmpump3AlmLaser2Fail "on", pmpump3AlmLaser2HwFail "*", pmpump3trapBoardNumber "$3"} --&MESG "Pre-Amp/IL2 Pump Up on PM PUMP3 in Slot $3 ($A)" --&FILTNAME "PM PUMP3 Pre-Amp/IL2 Pump HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmpump3AlmLaser2Fail "*", pmpump3AlmLaser2HwFail "on", pmpump3trapBoardNumber "$3"} --&MESG "Pre-Amp/IL2 Pump Up on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmpump3traps 35 } --- ***************************************************** --- PORTS TRAPS --- ***************************************************** pmpump3Laser1TrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Warning, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmpump3AlmLaser1Warning "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Warning appears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pmpump3traps 40 } pmpump3Laser1TrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Warning, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Booster/IL1 Pump Not Urgent ON"} --&MATCH { pmpump3AlmLaser1Warning "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Warning disappears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pmpump3traps 41 } pmpump3Laser1TrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Alm, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Urgent ON" --&ACTIONS { log, major } --&MATCH { pmpump3AlmLaser1Alm "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Alarms appears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pmpump3traps 42 } pmpump3Laser1TrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Alm, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Booster/IL1 Pump Urgent ON"} --&MATCH { pmpump3AlmLaser1Alm "on", pmpump3trapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Booster/IL1 Pump of PM PUMP3 in slot $2 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pmpump3traps 43 } pmpump3Laser1TrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Fail, pmpump3AlmLaser1HwFail, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Fail ON" --&ACTIONS { log, critical } --&MATCH { pmpump3AlmLaser1Fail "on", pmpump3AlmLaser1HwFail "*", pmpump3trapBoardNumber "$3"} --&MESG "Booster/IL1 Pump Down on PM PUMP3 in Slot $3 ($A)" --&FILTNAME "PM PUMP3 Booster/IL1 Pump HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmpump3AlmLaser1Fail "*", pmpump3AlmLaser1HwFail "on", pmpump3trapBoardNumber "$3"} --&MESG "Booster/IL1 Pump Down on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Critical client default is activated" ::= { pmpump3traps 44 } pmpump3Laser1TrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmLaser1Fail, pmpump3AlmLaser1HwFail, pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Booster/IL1 Pump Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PM PUMP3 Booster/IL1 Pump Fail ON" } --&MATCH { pmpump3AlmLaser1Fail "on", pmpump3AlmLaser1HwFail "*", pmpump3trapBoardNumber "$3"} --&MESG "Booster/IL1 Pump Up on PM PUMP3 in Slot $3 ($A)" --&FILTNAME "PM PUMP3 Booster/IL1 Pump HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmpump3AlmLaser1Fail "*", pmpump3AlmLaser1HwFail "on", pmpump3trapBoardNumber "$3"} --&MESG "Booster/IL1 Pump Up on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pmpump3traps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmpump3PowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmpump3AlmDefFuseB, pmpump3AlmDefFuseA , pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmpump3AlmDefFuseB "*", pmpump3AlmDefFuseA "on", pmpump3trapBoardNumber "$3"} --&MESG "Power Input A Fail on PM PUMP3 in Slot $3 ($A)" --&FILTNAME "PM PUMP3 Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmpump3AlmDefFuseB "on", pmpump3AlmDefFuseA "*", pmpump3trapBoardNumber "$3"} --&MESG "Power Input B Fail on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmpump3traps 50 } pmpump3PowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmpump3AlmDefFuseB, pmpump3AlmDefFuseA , pmpump3trapBoardNumber} STATUS current --&FILTNAME "PM PUMP3 Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PM PUMP3 Fuse A Fail ON", "PM PUMP3 Fuse B Fail ON" } --&MATCH { pmpump3AlmDefFuseB "on", pmpump3AlmDefFuseA "on", pmpump3trapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PM PUMP3 in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmpump3traps 51 } END