-- ***************************************************************** -- EKINOPS-pmoabphc.TXT: MIB -- --MIB Part Number:3MI00208AABE --MIB Version:01 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-PmOabphc-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulepmoabphc MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "Creation" REVISION "201107060000Z" DESCRIPTION "Initial Version." REVISION "201107060000Z" DESCRIPTION "Creation" REVISION "201302080000Z" DESCRIPTION "Ext Pump alarms" REVISION "201307010000Z" DESCRIPTION "Constant Gain function" REVISION "201309160000Z" DESCRIPTION "Help change" REVISION "201312020000Z" DESCRIPTION "Ext Pump Fail insertion" REVISION "201403260000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201412100000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 51 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmoabphcalarms OBJECT IDENTIFIER ::= { modulepmoabphc 2 } pmoabphcAlmOther OBJECT IDENTIFIER ::= { pmoabphcalarms 1 } pmoabphcAlmOtherNurg OBJECT IDENTIFIER ::= { pmoabphcAlmOther 1 } pmoabphcAlmOtherUrg OBJECT IDENTIFIER ::= { pmoabphcAlmOther 2 } pmoabphcAlmOtherCrit OBJECT IDENTIFIER ::= { pmoabphcAlmOther 3 } pmoabphcAlmClient OBJECT IDENTIFIER ::= { pmoabphcalarms 2 } pmoabphcAlmClientNurg OBJECT IDENTIFIER ::= { pmoabphcAlmClient 1 } pmoabphcAlmClientUrg OBJECT IDENTIFIER ::= { pmoabphcAlmClient 2 } pmoabphcAlmClientCrit OBJECT IDENTIFIER ::= { pmoabphcAlmClient 3 } pmoabphcAlmLine OBJECT IDENTIFIER ::= { pmoabphcalarms 3 } pmoabphcAlmLineNurg OBJECT IDENTIFIER ::= { pmoabphcAlmLine 1 } pmoabphcAlmLineUrg OBJECT IDENTIFIER ::= { pmoabphcAlmLine 2 } pmoabphcAlmLineCrit OBJECT IDENTIFIER ::= { pmoabphcAlmLine 3 } pmoabphcmeasures OBJECT IDENTIFIER ::= { modulepmoabphc 3 } pmoabphcMesrOther OBJECT IDENTIFIER ::= { pmoabphcmeasures 1 } pmoabphcMesrClient OBJECT IDENTIFIER ::= { pmoabphcmeasures 2 } pmoabphcMesrLine OBJECT IDENTIFIER ::= { pmoabphcmeasures 3 } pmoabphccontrolsWrite OBJECT IDENTIFIER ::= { modulepmoabphc 6 } pmoabphcCtrlOther OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 1 } pmoabphcCtrlClient OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 2 } pmoabphcCtrlLine OBJECT IDENTIFIER ::= { pmoabphccontrolsWrite 3 } pmoabphcri OBJECT IDENTIFIER ::= { modulepmoabphc 7 } pmoabphcConfig OBJECT IDENTIFIER ::= { modulepmoabphc 9 } pmoabphctraps OBJECT IDENTIFIER ::= { modulepmoabphc 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** PmoabphcpreampMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on OA preamp" SYNTAX INTEGER { oabphcpreampdefaultmode(0), oabphcpreampconstantcurrentmode(1), oabphcpreampconstantpowermode(2) oabphcpreampconstantgainmode(3) oabphcpreamppoutpinmode(4) oabphcpreampmanualmode(5) oabphcpreampfeedforwardmode(6) oabphcpreamptransientsupmode(7) } PmoabphcboosterMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on OA booster" SYNTAX INTEGER { oabphcboosterdefaultmode(0), oabphcboosterconstantcurrentmode(1), oabphcboosterconstantpowermode(2) oabphcboosterconstantgainmode(3) oabphcboosterpoutpinmode(4) oabphcboostermanualmode(5) oabphcboosterfeedforwardmode(6) oabphcboostertransientsupmode(7) } PmoabphcaprMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on APR" SYNTAX INTEGER { oabphcaproffmode(0), oabphcaprsemiautomode(1), oabphcaprautomode(2) oabphcaprlossforwardingmode(3) oabphcaprrepeatmode(4) } PmoabphcPreampGainAdjMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on Gain" SYNTAX INTEGER { oabphcpreampgainadjmanualmode(0), oabphcpreampgainadjsemiautomode(1), oabphcpreampgainadjautomode(2) } PmoabphcBoosterGainAdjMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on Gain" SYNTAX INTEGER { oabphcboostergainadjmanualmode(0), oabphcboostergainadjsemiautomode(1), oabphcboostergainadjautomode(2) } PmoabphcPreampCstGainAdjMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes when constant Gain" SYNTAX INTEGER { oabphcpreampcstgainadjsemiautomode(1), oabphcpreampcstgainadjautomode(2) } PmoabphcBoosterCstGainAdjMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes when constant Gain" SYNTAX INTEGER { oabphcboostercstgainadjsemiautomode(1), oabphcboostercstgainadjautomode(2) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmoabphcRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmoabphcri 2 } pmoabphcRinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmoabphcri 3 } pmoabphcRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmoabphcri 4 } pmoabphcRinvSwFoa OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Optical device driver description: This OID contains the description of the driver of the optical devices (Booster and Pre-Amp)" ::= { pmoabphcri 5 } pmoabphcRinvBoosterTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabphcRinvBoosterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the Boosters on the selected module" ::= { pmoabphcri 6 } pmoabphcRinvBoosterEntry OBJECT-TYPE SYNTAX PmoabphcRinvBoosterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the Boosters table" INDEX { pmoabphcRinvBoosterIndex } ::= { pmoabphcRinvBoosterTable 1 } PmoabphcRinvBoosterEntry::= SEQUENCE { pmoabphcRinvBoosterIndex Integer32, pmoabphcRinvBooster DisplayString } pmoabphcRinvBoosterIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for Booster table" ::= { pmoabphcRinvBoosterEntry 1 } pmoabphcRinvBooster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the Booster: This OID contains the inventory for the Booster" ::= { pmoabphcRinvBoosterEntry 2 } pmoabphcRinvPreAmpTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabphcRinvPreAmpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the PreAmps on the selected module" ::= { pmoabphcri 7 } pmoabphcRinvPreAmpEntry OBJECT-TYPE SYNTAX PmoabphcRinvPreAmpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the PreAmp table" INDEX { pmoabphcRinvPreAmpIndex } ::= { pmoabphcRinvPreAmpTable 1 } PmoabphcRinvPreAmpEntry::= SEQUENCE { pmoabphcRinvPreAmpIndex Integer32, pmoabphcRinvPreAmp DisplayString } pmoabphcRinvPreAmpIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for PreAmp table" ::= { pmoabphcRinvPreAmpEntry 1 } pmoabphcRinvPreAmp OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the PreAmp: This OID contains the inventory for the PreAmp" ::= { pmoabphcRinvPreAmpEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmoabphcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoabphcAlmOtherCrit 0 } pmoabphcAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm0 16 } pmoabphcAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm0 15 } pmoabphcAlmExtPump2NotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " External Pump2 Not Detected :This OID indicates that the second external pump is not detected by the amplifier module This alarm indicates if the second external pump is detected by the amplifier module EXT_PUMP2_NOT_LOCKED pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm0 13 } pmoabphcAlmExtPump1NotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " External Pump1 Not Detected :This OID indicates that the first external pump is not detected by the amplifier module This alarm indicates if the first external pump is detected by the amplifier module EXT_PUMP1_NOT_LOCKED pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm0 12 } pmoabphcAlmDwEdfaInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Not Initialized :This OID indicates that the initialisation of the Pre-Amp is not completed This status indicates if the Pre-Amp has been correctly initialized DW_EDFA_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmoabphcAlmsynthAlm0 11 } pmoabphcAlmUpEdfaInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Not Initialized :This OID indicates that the initialisation of the Booster is not completed This status indicates if the Booster has been correctly initialized UP_EDFA_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmoabphcAlmsynthAlm0 10 } pmoabphcAlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MOD_GLOB_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm0 9 } pmoabphcAlmAprOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Automatic Power Reduction :This OID indicates that the APR algorithm has been operated and the output of the lasers are shutdown The APR algorithm has been completed APR_ON other (1) other (1) (2) " ::= { pmoabphcAlmsynthAlm0 2 } pmoabphcAlmMaintenanceMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Maintenance Mode :This OID indicates that the PM is in maintenance mode This status indiates if the module is currently in maintenance mode MAINTENANCE_MODE other (1) other (1) (2) " ::= { pmoabphcAlmsynthAlm0 1 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmoabphcAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoabphcAlmOtherNurg 2 } pmoabphcAlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD bandwidthReduced(4) other (1) (2) " ::= { pmoabphcAlmsynthAlm2 3 } pmoabphcAlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD bandwidthReduced(4) other (1) (2) " ::= { pmoabphcAlmsynthAlm2 2 } pmoabphcAlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE bandwidthReduced(4) other (1) (2) " ::= { pmoabphcAlmsynthAlm2 1 } --- ***************************************************** --- LEAF for the synthAlm7 article --- ***************************************************** pmoabphcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoabphcAlmLineCrit 7 } pmoabphcAlmLineExtPumpFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster External Pump Fail :This OID indicates that the external pump linked to the Booster is in fail condition This alarm indicates if the external pump linked to the Booster is in fail condition LINE_EXT_PUMP_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm7 13 } pmoabphcAlmLineFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm7 12 } pmoabphcAlmLineDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM LINE_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm7 10 } pmoabphcAlmLineDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM LINE_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm7 9 } pmoabphcAlmLineTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Optical Output Shutdown :This OID indicates the Booster optical output power is on This status indicates if the Booster laser pump is ON or OFF LINE_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm7 5 } pmoabphcAlmLineHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm7 4 } --- ***************************************************** --- LEAF for the synthAlm8 article --- ***************************************************** pmoabphcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoabphcAlmClientCrit 8 } pmoabphcAlmClientExtPumpFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp External Pump Fail :This OID indicates that the external pump linked to the Pre-Amp is in fail condition This alarm indicates if the external pump linked to the Pre-Amp is in fail condition CLIENT_EXT_PUMP_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm8 13 } pmoabphcAlmClientFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Port Failure :This OID indicates a failure on the Client port CLIENT_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm8 12 } pmoabphcAlmClientDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Client Optical Module DDM :This OID indicates an alarm is present coming out of Client optical interface DDM CLIENT_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm8 10 } pmoabphcAlmClientDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Client Optical Module DDM :This OID indicates a warning is present coming out of Client optical interface DDM CLIENT_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm8 9 } pmoabphcAlmClientTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Optical Output Shutdown :This OID indicates the Pre-Amp optical output power is on This status indicates if the Pre-Amp laser pump transceiver laser is ON or OFF CLIENT_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmoabphcAlmsynthAlm8 5 } pmoabphcAlmClientHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue CLIENT_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabphcAlmsynthAlm8 4 } --- ***************************************************** --- LEAF for the clientEdfaAlarms1 article --- ***************************************************** pmoabphcAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcAlmClientUrg 32 } pmoabphcAlmClientBiasHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp bias is too high CLIENT_BIAS_HIGH_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 8 } pmoabphcAlmClientBiasLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp bias is too low CLIENT_BIAS_LOW_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 7 } pmoabphcAlmClientOutputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp tx power is too high CLIENT_OUTPUT_PWR_HIGH_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 6 } pmoabphcAlmClientOutputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp tx power is too low CLIENT_OUTPUT_PWR_LOW_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 5 } pmoabphcAlmClientInputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster rx power is too high CLIENT_INPUT_PWR_HIGH_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 4 } pmoabphcAlmClientInputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster rx power is too low CLIENT_INPUT_PWR_LOW_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 3 } pmoabphcAlmClientGainHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Pre-Amp Module This alarm indicates if the Pre-Amp gain is too high CLIENT_GAIN_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 2 } pmoabphcAlmClientGainLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the Pre-Amp Module This alarm indicates if the Pre-Amp gain is too low CLIENT_GAIN_LOW_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms1 1 } --- ***************************************************** --- LEAF for the clientEdfaWarnings article --- ***************************************************** pmoabphcAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmClientNurg 33 } pmoabphcAlmClientBiasHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp bias is too high CLIENT_BIAS_HIGH_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 8 } pmoabphcAlmClientBiasLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp bias is too low CLIENT_BIAS_LOW_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 7 } pmoabphcAlmClientOutputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp tx power is too high CLIENT_OUTPUT_PWR_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 6 } pmoabphcAlmClientOutputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp tx power is too low CLIENT_OUTPUT_PWR_LOW_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 5 } pmoabphcAlmClientInputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster rx power is too high CLIENT_INPUT_PWR_HIGH_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 4 } pmoabphcAlmClientInputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster rx power is too low CLIENT_INPUT_PWR_LOW_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 3 } pmoabphcAlmClientGainHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Pre-Amp Module This alarm indicates if the Pre-Amp gain is too high CLIENT_GAIN_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 2 } pmoabphcAlmClientGainLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the Pre-Amp Module This alarm indicates if the Pre-Amp gain is too low CLIENT_GAIN_LOW_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaWarnings 1 } --- ***************************************************** --- LEAF for the clientEdfaAlarms2 article --- ***************************************************** pmoabphcAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcAlmClientCrit 35 } pmoabphcAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Pump Low Current :This OID indicates that the EDFA pump current of Pre-Amp is too low because of the external pump high power This alarm (only active when there is at least on external pump) indicates that the EDFA pump current of the Pre-Amp is too low because of the external pump high power. CLIENT_EXT_PUMP_EDFA_LOW_CURRENT pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms2 5 } pmoabphcAlmClientEdfaLos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Loss Of Signal :This OID indicates a Loss of Signal on the Booster Optical Module This alarm indicates if an optical signal is detected on the Booster input CLIENT_EDFA_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pmoabphcAlmclientEdfaAlarms2 4 } pmoabphcAlmClientEdfaLaserFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Pre-Amp Optical Module This alarm indicates if the laser of the Pre-Amp is in fail condition CLIENT_EDFA_LASER_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms2 3 } pmoabphcAlmClientEdfaTecFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp TEC Fail :This OID indicates that the TEC is in fail condition on the Pre-Amp Optical Module This alarm indicates if the TEC of the Pre-Amp is in fail condition CLIENT_EDFA_TEC_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms2 2 } pmoabphcAlmClientEdfaNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Optical Module Not Ready :This OID indicates that the Pre-Amp Optical Module is not ready This status indicates if the Pre-Amp has been correctly initialized CLIENT_EDFA_NR equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmoabphcAlmclientEdfaAlarms2 1 } --- ***************************************************** --- LEAF for the lineEdfaAlarms1 article --- ***************************************************** pmoabphcAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabphcAlmLineUrg 40 } pmoabphcAlmLineBiasHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster bias is too high LINE_BIAS_HIGH_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 8 } pmoabphcAlmLineBiasLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster bias is too low LINE_BIAS_LOW_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 7 } pmoabphcAlmLineOutputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster tx power is too high LINE_OUTPUT_PWR_HIGH_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 6 } pmoabphcAlmLineOutputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster tx power is too low LINE_OUTPUT_PWR_LOW_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 5 } pmoabphcAlmLineInputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp rx power is too high LINE_INPUT_PWR_HIGH_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 4 } pmoabphcAlmLineInputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the Pre-Amp Optical Module This alarm indicates if the Pre-Amp rx power is too low LINE_INPUT_PWR_LOW_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 3 } pmoabphcAlmLineGainHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Booster Module This alarm indicates if the Booster gain is too high LINE_GAIN_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 2 } pmoabphcAlmLineGainLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the Booster Module This alarm indicates if the Booster gain is too low LINE_GAIN_LOW_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms1 1 } --- ***************************************************** --- LEAF for the lineEdfaWarnings article --- ***************************************************** pmoabphcAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmLineNurg 41 } pmoabphcAlmLineBiasHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster bias is too high LINE_BIAS_HIGH_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 8 } pmoabphcAlmLineBiasLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster bias is too low LINE_BIAS_LOW_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 7 } pmoabphcAlmLineOutputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster tx power is too high LINE_OUTPUT_PWR_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 6 } pmoabphcAlmLineOutputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster tx power is too low LINE_OUTPUT_PWR_LOW_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 5 } pmoabphcAlmLineInputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp rx power is too high LINE_INPUT_PWR_HIGH_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 4 } pmoabphcAlmLineInputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the Pre-Amp Optical Module This warning indicates if the Pre-Amp rx power is too low LINE_INPUT_PWR_LOW_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 3 } pmoabphcAlmLineGainHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Booster Module This alarm indicates if the Booster gain is too high LINE_GAIN_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 2 } pmoabphcAlmLineGainLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the Booster Module This alarm indicates if the Booster gain is too low LINE_GAIN_LOW_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaWarnings 1 } --- ***************************************************** --- LEAF for the lineEdfaAlarms2 article --- ***************************************************** pmoabphcAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabphcAlmLineCrit 43 } pmoabphcAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Pump Low Current :This OID indicates that the EDFA pump current of Booster is too low because of the external pump high power This alarm (only active when there is at least on external pump) indicates that the EDFA pump current of the Booster is too low because of the external pump high power. LINE_EXT_PUMP_EDFA_LOW_CURRENT pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms2 5 } pmoabphcAlmLineEdfaLos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Loss Of Signal :This OID indicates a Loss of Signal on the Pre-Amp Optical Module This alarm indicates if an optical signal is detected on the Pre-Amp input LINE_EDFA_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pmoabphcAlmlineEdfaAlarms2 4 } pmoabphcAlmLineEdfaLaserFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Booster Optical Module This alarm indicates if the laser of the Booster is in fail condition LINE_EDFA_LASER_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms2 3 } pmoabphcAlmLineEdfaTecFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster TEC Fail :This OID indicates that the TEC is in fail condition on the Booster Optical Module This alarm indicates if the TEC of the Booster is in fail condition LINE_EDFA_TEC_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms2 2 } pmoabphcAlmLineEdfaNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Optical Module Not Ready :This OID indicates that the Booster Optical Module is not ready This status indicates if the Booster has been correctly initialized LINE_EDFA_NR equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmoabphcAlmlineEdfaAlarms2 1 } --- ***************************************************** --- LEAF for the foaAlarms article --- ***************************************************** pmoabphcAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoabphcAlmOtherUrg 74 } pmoabphcAlmTempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold TEMP_HIGH_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabphcAlmfoaAlarms 8 } pmoabphcAlmTermpLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold TERMP_LOW_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabphcAlmfoaAlarms 7 } --- ***************************************************** --- LEAF for the foaWarnings article --- ***************************************************** pmoabphcAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoabphcAlmOtherNurg 75 } pmoabphcAlmTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabphcAlmfoaWarnings 8 } pmoabphcAlmTermpLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold TERMP_LOW_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabphcAlmfoaWarnings 7 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmoabphcCtrlsynth0 OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 0 } pmoabphcCtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmoabphcCtrlsynth0 13 } pmoabphcCtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmoabphcCtrlsynth0 9 } pmoabphcCtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmoabphcCtrlsynth0 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmoabphcCtrlswMgnt OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 5 } pmoabphcCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmoabphcCtrlswMgnt 3 } pmoabphcCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmoabphcCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the clientEdfaLaserOff article --- ***************************************************** pmoabphcCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabphcCtrlClient 32 } pmoabphcCtrlClientEdfaLaserOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Optical Module Laser Off :This OID switches OFF the laser of the Pre-Amp Optical Module This control defines the laser state of the Pre-Amp " ::= { pmoabphcCtrlclientEdfaLaserOff 1 } --- ***************************************************** --- LEAF for the clientGainCstMonitorValue article --- ***************************************************** pmoabphcCtrlclientGainCstMonitorValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a fiber aging. " ::= { pmoabphcCtrlClient 34 } --- ***************************************************** --- LEAF for the clientGainCstPoutValue article --- ***************************************************** pmoabphcCtrlclientGainCstPoutValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Ref Pout :This OID sets the value of the reference output power used to compensate the fiber aging (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dBm) This value defines the reference output power used to compensate the fiber aging " ::= { pmoabphcCtrlClient 35 } --- ***************************************************** --- LEAF for the clientGainSettingValue article --- ***************************************************** pmoabphcCtrlclientGainSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Gain Target :This OID sets the value of the nominal gain of the Pre-Amplifier Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This control sets the value of the nominal gain of the Pre- Amplifier Module (active only in constant output power mode) " ::= { pmoabphcCtrlClient 36 } --- ***************************************************** --- LEAF for the clientGainProcessing article --- ***************************************************** pmoabphcCtrlclientGainProcessing OBJECT IDENTIFIER ::= { pmoabphcCtrlClient 37 } pmoabphcCtrlClientGainProc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the Pre-Amplifier Module This control initiates the automatic nominal gain adjustment on the Pre-Amplifier Module " ::= { pmoabphcCtrlclientGainProcessing 1 } --- ***************************************************** --- LEAF for the clientGainCstFiberAgingMarginValue article --- ***************************************************** pmoabphcCtrlclientGainCstFiberAgingMarginValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This value defines the threshold to consider the power drop as a fiber aging. " ::= { pmoabphcCtrlClient 38 } --- ***************************************************** --- LEAF for the clientGainCstAdddropMarginValue article --- ***************************************************** pmoabphcCtrlclientGainCstAdddropMarginValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Pre-Amp AddDrop Threshold :This OID sets the threshold to not consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This value defines the threshold to not consider the power drop as a fiber aging. " ::= { pmoabphcCtrlClient 39 } --- ***************************************************** --- LEAF for the lineEdfaLaserOff article --- ***************************************************** pmoabphcCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabphcCtrlLine 40 } pmoabphcCtrlLineEdfaLaserOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Optical Module Laser Off :This OID switches OFF the laser of the Booster Optical Module This control defines the laser state of the Booster " ::= { pmoabphcCtrllineEdfaLaserOff 1 } --- ***************************************************** --- LEAF for the lineGainCstMonitorValue article --- ***************************************************** pmoabphcCtrllineGainCstMonitorValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Fiber Aging Period :This OID sets the value of the monitoring period to detect a fiber aging. (Unit = s) This value sets the monitoring period to detect a fiber aging. " ::= { pmoabphcCtrlLine 42 } --- ***************************************************** --- LEAF for the lineGainCstPoutValue article --- ***************************************************** pmoabphcCtrllineGainCstPoutValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Ref Pout :This OID sets the value of the reference output power used to compensate the fiber aging (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dBm) This value defines the reference output power used to compensate the fiber aging " ::= { pmoabphcCtrlLine 43 } --- ***************************************************** --- LEAF for the lineGainSettingValue article --- ***************************************************** pmoabphcCtrllineGainSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Gain Target :This OID sets the value of the nominal gain of the Booster Module (active only in constant output power mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This control sets the value of the nominal gain of the Booster Module (active only in constant output power mode) " ::= { pmoabphcCtrlLine 44 } --- ***************************************************** --- LEAF for the lineGainProcessing article --- ***************************************************** pmoabphcCtrllineGainProcessing OBJECT IDENTIFIER ::= { pmoabphcCtrlLine 45 } pmoabphcCtrlLineGainProc OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Gain Adjustment :This OID initiates the automatic nominal gain adjustment on the Booster Module This control initiates the automatic nominal gain adjustment on the Booster Module " ::= { pmoabphcCtrllineGainProcessing 1 } --- ***************************************************** --- LEAF for the lineGainCstFiberAgingMarginValue article --- ***************************************************** pmoabphcCtrllineGainCstFiberAgingMarginValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Aging Threshold :This OID sets the threshold to consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This value defines the threshold to consider the power drop as a fiber aging. " ::= { pmoabphcCtrlLine 46 } --- ***************************************************** --- LEAF for the lineGainCstAdddropMarginValue article --- ***************************************************** pmoabphcCtrllineGainCstAdddropMarginValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster AddDrop Threshold :This OID sets the threshold to not consider the power drop as a fiber aging. (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) This value defines the threshold to not consider the power drop as a fiber aging. " ::= { pmoabphcCtrlLine 47 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmoabphcCtrlledTest OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 73 } pmoabphcCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmoabphcCtrlledTest 3 } pmoabphcCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmoabphcCtrlledTest 2 } pmoabphcCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmoabphcCtrlledTest 1 } --- ***************************************************** --- LEAF for the maintMode article --- ***************************************************** pmoabphcCtrlmaintMode OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 75 } pmoabphcCtrlMaintenance OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Maintenance Mode :This OID sets the PM in maintenance mode This control enables the maintenance mode of the module " ::= { pmoabphcCtrlmaintMode 1 } --- ***************************************************** --- LEAF for the aprRestart article --- ***************************************************** pmoabphcCtrlaprRestart OBJECT IDENTIFIER ::= { pmoabphcCtrlOther 76 } pmoabphcCtrlAprManualRestart OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " APR Manual Restart :This OID initiates the Restart mechanism to retrieve from the APR state. This control initiates the Restart mechanism to retrieve from the APR state. " ::= { pmoabphcCtrlaprRestart 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the clientEdfaBiasMeas article --- ***************************************************** pmoabphcMesrclientEdfaBiasMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Pump Laser Current :This OID gives the pump laser current of the Pre-Amp Optical Module (Current =AV/100) (Unit = mA) This measure gives the bias of the Pre-Amp pump laser " ::= { pmoabphcMesrClient 32 } --- ***************************************************** --- LEAF for the clientEdfaTxpwrMeas article --- ***************************************************** pmoabphcMesrclientEdfaTxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Tx Power :This OID gives the transmit power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Tx optical power of the Pre-Amp " ::= { pmoabphcMesrClient 33 } --- ***************************************************** --- LEAF for the clientEdfaRxpwrMeas article --- ***************************************************** pmoabphcMesrclientEdfaRxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Rx optical power of the Booster " ::= { pmoabphcMesrClient 34 } --- ***************************************************** --- LEAF for the clientEdfaGainMeas article --- ***************************************************** pmoabphcMesrclientEdfaGainMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain Target :This OID gives the gain value of the Pre-Amp Module (Gain =(AV-32768)*0,005) (Unit = dB) This information gives the target gain of the amplifier for optimal performance " ::= { pmoabphcMesrClient 35 } --- ***************************************************** --- LEAF for the clientCorrectedGain article --- ***************************************************** pmoabphcMesrclientCorrectedGain OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Gain :This OID gives the gain value of the Pre-Amp Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) This measure gives the effective gain of the amplifier " ::= { pmoabphcMesrClient 38 } --- ***************************************************** --- LEAF for the lineEdfaBiasMeas article --- ***************************************************** pmoabphcMesrlineEdfaBiasMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Pump Laser Current :This OID gives the pump laser current of the Booster Optical Module (Current =AV/100) (Unit = mA) This measure gives the bias of the Booster pump laser " ::= { pmoabphcMesrLine 40 } --- ***************************************************** --- LEAF for the lineEdfaTxpwrMeas article --- ***************************************************** pmoabphcMesrlineEdfaTxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Tx optical power of the Booster " ::= { pmoabphcMesrLine 41 } --- ***************************************************** --- LEAF for the lineEdfaRxpwrMeas article --- ***************************************************** pmoabphcMesrlineEdfaRxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Rx Power :This OID gives the receive power value of the Pre-Amp Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Rx optical power of the Pre-Amp " ::= { pmoabphcMesrLine 42 } --- ***************************************************** --- LEAF for the lineEdfaGainMeas article --- ***************************************************** pmoabphcMesrlineEdfaGainMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain Target :This OID gives the gain value of the Booster Module (Gain =(AV-32768)*0,005) (Unit = dB) This information gives the target gain of the amplifier for optimal performance " ::= { pmoabphcMesrLine 43 } --- ***************************************************** --- LEAF for the lineCorrectedGain article --- ***************************************************** pmoabphcMesrlineCorrectedGain OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain :This OID gives the gain value of the Booster Module corrected by the ASE compensation mechanism (Gain =(AV-32768)*0,005) (Unit = dB) This measure gives the effective gain of the amplifier " ::= { pmoabphcMesrLine 46 } --- ***************************************************** --- LEAF for the tempMeas article --- ***************************************************** pmoabphcMesrtempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature :This OID gives the temperature of the PM (Temperature =AV/256) (Unit = C) This measure gives the temperature of the module " ::= { pmoabphcMesrOther 72 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group noValue --- ***************************************************** pmoabphcCfgNoValue OBJECT IDENTIFIER ::= { pmoabphcConfig 1 } --- ***************************************************** --- LEAF for the table 2111 --- ***************************************************** pmoabphctableclientStartup OBJECT IDENTIFIER ::= { pmoabphcCfgNoValue 1 } pmoabphcCfgclientEdfaLaserCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Laser :This OID configures the default initialisation settings on the client laser. " ::= { pmoabphctableclientStartup 2 } pmoabphcCfgclientEdfaLaserMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client mode :This OID configures the default mode on the client amplifier. " ::= { pmoabphctableclientStartup 3 } pmoabphcCfgclientGainValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Gain :This OID configures the default gain on the client amplifier. " ::= { pmoabphctableclientStartup 4 } pmoabphcCfgclientTiltValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Tilt :This OID configures the default tilt on the client amplifier. " ::= { pmoabphctableclientStartup 5 } pmoabphcCfgclientMsaLoss OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client MSA :This OID configures the default MSA value on the client amplifier. " ::= { pmoabphctableclientStartup 6 } pmoabphcCfgclientOutputPowerValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client Output power :This OID configures the default Output power value on the client amplifier. " ::= { pmoabphctableclientStartup 7 } pmoabphcCfgclientAseCompensation OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Client ASE :This OID configures the default ASE compensation value on the client amplifier. " ::= { pmoabphctableclientStartup 8 } --- ***************************************************** --- LEAF for the table Group lineStartUp --- ***************************************************** pmoabphcCfgLineStartUp OBJECT IDENTIFIER ::= { pmoabphcConfig 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pmoabphctablelineStartup OBJECT IDENTIFIER ::= { pmoabphcCfgLineStartUp 1 } pmoabphcCfglineEdfaLaserCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. " ::= { pmoabphctablelineStartup 2 } pmoabphcCfglineEdfaLaserMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line mode :This OID configures the default mode on the line amplifier. " ::= { pmoabphctablelineStartup 3 } pmoabphcCfglineGainValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line Gain :This OID configures the default gain on the line amplifier. " ::= { pmoabphctablelineStartup 4 } pmoabphcCfglineTiltValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line Tilt :This OID configures the default tilt on the line amplifier. " ::= { pmoabphctablelineStartup 5 } pmoabphcCfglineMsaLoss OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line MSA :This OID configures the default MSA value on the line amplifier. " ::= { pmoabphctablelineStartup 6 } pmoabphcCfglineOutputPowerValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line Output power :This OID configures the default Output power value on the line amplifier. " ::= { pmoabphctablelineStartup 7 } pmoabphcCfglineAseCompensation OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line ASE :This OID configures the default ASE compensation value on the line amplifier. " ::= { pmoabphctablelineStartup 8 } pmoabphcCfgaprMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default setting on module :This OID configures the default mode on the APR " ::= { pmoabphctablelineStartup 11 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmoabphcCfgLabels OBJECT IDENTIFIER ::= { pmoabphcConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmoabphcCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabphcCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmoabphcCfgLabels 1 } pmoabphcCfgLabelclientEntry OBJECT-TYPE SYNTAX PmoabphcCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmoabphcCfgLabelclientIndex } ::= { pmoabphcCfgLabelclientTable 1 } PmoabphcCfgLabelclientEntry ::= SEQUENCE { pmoabphcCfgLabelclientIndex INTEGER, pmoabphcCfgLabelclientPortn DisplayString } pmoabphcCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmoabphcCfgLabelclientEntry 1 } pmoabphcCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmoabphcCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmoabphcCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabphcCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmoabphcCfgLabels 2 } pmoabphcCfgLabellineEntry OBJECT-TYPE SYNTAX PmoabphcCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmoabphcCfgLabellineIndex } ::= { pmoabphcCfgLabellineTable 1 } PmoabphcCfgLabellineEntry ::= SEQUENCE { pmoabphcCfgLabellineIndex INTEGER, pmoabphcCfgLabellinePortn DisplayString } pmoabphcCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmoabphcCfgLabellineEntry 1 } pmoabphcCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmoabphcCfgLabellineEntry 3 } pmoabphcCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmoabphcConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmoabphctrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmoabphctraps 4 } --- ***************************************************** --- GLOBAL TRAPS --- ***************************************************** pmoabphcLineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineDdmWarning, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmoabphcAlmLineDdmWarning "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Warning appears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pmoabphctraps 30 } pmoabphcLineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineDdmWarning, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Line Not Urgent ON"} --&MATCH { pmoabphcAlmLineDdmWarning "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pmoabphctraps 31 } pmoabphcLineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineDdmAlm, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pmoabphcAlmLineDdmAlm "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pmoabphctraps 32 } pmoabphcLineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineDdmAlm, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Line Urgent ON"} --&MATCH { pmoabphcAlmLineDdmAlm "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pmoabphctraps 33 } pmoabphcLineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineFail, pmoabphcAlmLineHwFail, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pmoabphcAlmLineFail "on", pmoabphcAlmLineHwFail "*", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)" --&FILTNAME "PMOABPHC Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmoabphcAlmLineFail "*", pmoabphcAlmLineHwFail "on", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmoabphctraps 34 } pmoabphcLineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmLineFail, pmoabphcAlmLineHwFail, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Line Fail ON"} --&MATCH { pmoabphcAlmLineFail "on", pmoabphcAlmLineHwFail "*", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)" --&FILTNAME "PMOABPHC Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmoabphcAlmLineFail "*", pmoabphcAlmLineHwFail "on", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOABPHC in slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmoabphctraps 35 } --- ***************************************************** --- PORTS TRAPS --- ***************************************************** pmoabphcClientTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientDdmWarning, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmoabphcAlmClientDdmWarning "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Warning appears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pmoabphctraps 40 } pmoabphcClientTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientDdmWarning, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Client Not Urgent ON"} --&MATCH { pmoabphcAlmClientDdmWarning "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pmoabphctraps 41 } pmoabphcClientTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientDdmAlm, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Urgent ON" --&ACTIONS { log, major } --&MATCH { pmoabphcAlmClientDdmAlm "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pmoabphctraps 42 } pmoabphcClientTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientDdmAlm, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Client Urgent ON"} --&MATCH { pmoabphcAlmClientDdmAlm "on", pmoabphctrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $2 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pmoabphctraps 43 } pmoabphcClientTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientFail, pmoabphcAlmClientHwFail, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Fail ON" --&ACTIONS { log, critical } --&MATCH { pmoabphcAlmClientFail "on", pmoabphcAlmClientHwFail "*", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)" --&FILTNAME "PMOABPHC Client HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmoabphcAlmClientFail "*", pmoabphcAlmClientHwFail "on", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)" DESCRIPTION "Critical client default is activated" ::= { pmoabphctraps 44 } pmoabphcClientTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmClientFail, pmoabphcAlmClientHwFail, pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Client Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOABPHC Client Fail ON"} --&MATCH { pmoabphcAlmClientFail "on", pmoabphcAlmClientHwFail "*", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)" --&FILTNAME "PMOABPHC Client HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmoabphcAlmClientFail "*", pmoabphcAlmClientHwFail "on", pmoabphctrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOABPHC in slot $3 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pmoabphctraps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmoabphcPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabphcAlmDefFuseB, pmoabphcAlmDefFuseA , pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmoabphcAlmDefFuseB "*", pmoabphcAlmDefFuseA "on", pmoabphctrapBoardNumber "$3"} --&MESG "Power Input A Fail on PMOABPHC in Slot $3 ($A)" --&FILTNAME "PMOABPHC Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmoabphcAlmDefFuseB "on", pmoabphcAlmDefFuseA "*", pmoabphctrapBoardNumber "$3"} --&MESG "Power Input B Fail on PMOABPHC in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmoabphctraps 50 } pmoabphcPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabphcAlmDefFuseB, pmoabphcAlmDefFuseA , pmoabphctrapBoardNumber} STATUS current --&FILTNAME "PMOABPHC Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMOABPHC Fuse A Fail ON", "PMOABPHC Fuse B Fail ON" } --&MATCH { pmoabphcAlmDefFuseB "on", pmoabphcAlmDefFuseA "on", pmoabphctrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMOABPHC in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmoabphctraps 51 } END