-- ***************************************************************** -- EKINOPS-pmoab.TXT: MIB -- --MIB Part Number:3MI00202AJAD --MIB Version:01 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-PmOab-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulepmoab MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "MIB for the Ekinops pmoab hardware." REVISION "200702070000Z" DESCRIPTION "Initial Version." REVISION "200707060000Z" DESCRIPTION "°C changed to C" REVISION "200711210000Z" DESCRIPTION "Update Ekinops address, Helps on objects, Ports labels" REVISION "200904150000Z" DESCRIPTION "Add ext Pumps features" REVISION "200909210000Z" DESCRIPTION "Add CondType parameters" REVISION "200912140000Z" DESCRIPTION "Correction on traps" REVISION "201002250000Z" DESCRIPTION "Probcause,AlarmType - NMS" REVISION "201007150000Z" DESCRIPTION "Add inventory object for the NMS" REVISION "201010290000Z" DESCRIPTION "Formula in comments, Objetcs removal" REVISION "201011030000Z" DESCRIPTION "Modify inventory object for the NMS" REVISION "201207040000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403260000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201412100000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 23 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmoabalarms OBJECT IDENTIFIER ::= { modulepmoab 2 } pmoabAlmOther OBJECT IDENTIFIER ::= { pmoabalarms 1 } pmoabAlmOtherNurg OBJECT IDENTIFIER ::= { pmoabAlmOther 1 } pmoabAlmOtherUrg OBJECT IDENTIFIER ::= { pmoabAlmOther 2 } pmoabAlmOtherCrit OBJECT IDENTIFIER ::= { pmoabAlmOther 3 } pmoabAlmClient OBJECT IDENTIFIER ::= { pmoabalarms 2 } pmoabAlmClientNurg OBJECT IDENTIFIER ::= { pmoabAlmClient 1 } pmoabAlmClientUrg OBJECT IDENTIFIER ::= { pmoabAlmClient 2 } pmoabAlmClientCrit OBJECT IDENTIFIER ::= { pmoabAlmClient 3 } pmoabAlmLine OBJECT IDENTIFIER ::= { pmoabalarms 3 } pmoabAlmLineNurg OBJECT IDENTIFIER ::= { pmoabAlmLine 1 } pmoabAlmLineUrg OBJECT IDENTIFIER ::= { pmoabAlmLine 2 } pmoabAlmLineCrit OBJECT IDENTIFIER ::= { pmoabAlmLine 3 } pmoabmeasures OBJECT IDENTIFIER ::= { modulepmoab 3 } pmoabMesrOther OBJECT IDENTIFIER ::= { pmoabmeasures 1 } pmoabMesrClient OBJECT IDENTIFIER ::= { pmoabmeasures 2 } pmoabMesrLine OBJECT IDENTIFIER ::= { pmoabmeasures 3 } pmoabcontrolsWrite OBJECT IDENTIFIER ::= { modulepmoab 6 } pmoabCtrlOther OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 1 } pmoabCtrlClient OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 2 } pmoabCtrlLine OBJECT IDENTIFIER ::= { pmoabcontrolsWrite 3 } pmoabri OBJECT IDENTIFIER ::= { modulepmoab 7 } pmoabConfig OBJECT IDENTIFIER ::= { modulepmoab 9 } pmoabtraps OBJECT IDENTIFIER ::= { modulepmoab 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** PmoabboosterMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on OA booster" SYNTAX INTEGER { oaboosterdefaultmode(0), oaboosterconstantcurrentmode(1), oaboosterconstantpowermode(2) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmoabRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmoabri 2 } pmoabRinvModulePlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmoabri 3 } pmoabRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmoabri 4 } pmoabRinvSwFoa OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Optical device driver description: This OID contains the description of the driver of the optical devices (Booster and Pre-Amp)" ::= { pmoabri 5 } pmoabRinvBoosterTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabRinvBoosterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of the Boosters on the selected module" ::= { pmoabri 6 } pmoabRinvBoosterEntry OBJECT-TYPE SYNTAX PmoabRinvBoosterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Row definition for the Boosters table" INDEX { pmoabRinvBoosterIndex } ::= { pmoabRinvBoosterTable 1 } PmoabRinvBoosterEntry::= SEQUENCE { pmoabRinvBoosterIndex Integer32, pmoabRinvBooster DisplayString } pmoabRinvBoosterIndex OBJECT-TYPE SYNTAX Integer32(1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "Index for Booster table" ::= { pmoabRinvBoosterEntry 1 } pmoabRinvBooster OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the Booster: This OID contains the inventory for the Booster" ::= { pmoabRinvBoosterEntry 2 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmoabAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoabAlmOtherCrit 0 } pmoabAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmsynthAlm0 16 } pmoabAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmsynthAlm0 15 } pmoabAlmExtPumpNotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " External Pump1 Not Detected :This OID indicates that the first external pump is not detected by the amplifier module This alarm indicates if the first external pump is detected by the amplifier module EXT_PUMP_NOT_LOCKED pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmsynthAlm0 12 } pmoabAlmDwEdfaInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Pre-Amp Not Initialized :This OID indicates that the initialisation of the Pre-Amp is not completed DW_EDFA_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmoabAlmsynthAlm0 11 } pmoabAlmUpEdfaInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Not Initialized :This OID indicates that the initialisation of the Booster is not completed This status indicates if the Booster has been correctly initialized UP_EDFA_INIT_NOT_COMPL other (1) other (1) (2) " ::= { pmoabAlmsynthAlm0 10 } pmoabAlmModGlobFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MOD_GLOB_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm0 9 } pmoabAlmMaintenanceMode OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Maintenance Mode :This OID indicates that the PM is in maintenance mode This status indiates if the module is currently in maintenance mode MAINTENANCE_MODE other (1) other (1) (2) " ::= { pmoabAlmsynthAlm0 1 } --- ***************************************************** --- LEAF for the synthAlm2 article --- ***************************************************** pmoabAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoabAlmOtherNurg 2 } pmoabAlmConfTableLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Load :This OID is at 1 during the loading of configuration tables in the modules RAM. CONF_TABLE_LOAD other (1) other (1) (2) " ::= { pmoabAlmsynthAlm2 3 } pmoabAlmInvUpload OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Inventory Upload :This OID is at 1 during the uploading of PM inventory information. INV_UPLOAD other (1) other (1) (2) " ::= { pmoabAlmsynthAlm2 2 } pmoabAlmConfTableSave OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " PM Configuration Save :This OID is at 1 during the saving of a new configuration table in the module Flash memory. CONF_TABLE_SAVE other (1) other (1) (2) " ::= { pmoabAlmsynthAlm2 1 } --- ***************************************************** --- LEAF for the synthAlm7 article --- ***************************************************** pmoabAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoabAlmLineCrit 7 } pmoabAlmLineFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port Failure :This OID indicates a failure on the line port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm7 12 } pmoabAlmLineDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line Optical Module DDM :This OID indicates an alarm is present coming out of Line optical interface DDM LINE_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm7 10 } pmoabAlmLineDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line Optical Module DDM :This OID indicates a warning is present coming out of Line optical interface DDM LINE_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm7 9 } pmoabAlmLineTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Optical Output Shutdown :This OID indicates the Booster optical output power is on This status indicates if the Booster laser pump is ON or OFF LINE_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pmoabAlmsynthAlm7 5 } pmoabAlmLineHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line Port HW Failure :This OID indicates a failure on line port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm7 4 } --- ***************************************************** --- LEAF for the synthAlm8 article --- ***************************************************** pmoabAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoabAlmClientCrit 8 } pmoabAlmClientFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Port Failure :This OID indicates a failure on the Client port CLIENT_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm8 12 } pmoabAlmClientDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Client Optical Module DDM :This OID indicates an alarm is present coming out of Client optical interface DDM CLIENT_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm8 10 } pmoabAlmClientDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Client Optical Module DDM :This OID indicates a warning is present coming out of Client optical interface DDM CLIENT_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm8 9 } pmoabAlmClientHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Client Port HW Failure :This OID indicates a failure on Client port, most probably caused by a HW issue CLIENT_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmoabAlmsynthAlm8 4 } --- ***************************************************** --- LEAF for the clientEdfaAlarms1 article --- ***************************************************** pmoabAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabAlmClientUrg 32 } pmoabAlmClientInputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr High Alarm :This OID indicates that the Receive Power is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster rx power is too high CLIENT_INPUT_PWR_HIGH_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabAlmclientEdfaAlarms1 4 } pmoabAlmClientInputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr Low Alarm :This OID indicates that the Receive Power is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster rx power is too low CLIENT_INPUT_PWR_LOW_ALARM receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabAlmclientEdfaAlarms1 3 } --- ***************************************************** --- LEAF for the clientEdfaWarnings article --- ***************************************************** pmoabAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoabAlmClientNurg 33 } pmoabAlmClientInputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr High Warning :This OID indicates that the Receive Power is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster rx power is too high CLIENT_INPUT_PWR_HIGH_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabAlmclientEdfaWarnings 4 } pmoabAlmClientInputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Pwr Low Warning :This OID indicates that the Receive Power is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster rx power is too low CLIENT_INPUT_PWR_LOW_WARNING receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmoabAlmclientEdfaWarnings 3 } --- ***************************************************** --- LEAF for the clientEdfaAlarms2 article --- ***************************************************** pmoabAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabAlmClientCrit 35 } pmoabAlmClientEdfaLos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Loss Of Signal :This OID indicates a Loss of Signal on the Booster Optical Module This alarm indicates if an optical signal is detected on the Booster input CLIENT_EDFA_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pmoabAlmclientEdfaAlarms2 4 } --- ***************************************************** --- LEAF for the lineEdfaAlarms1 article --- ***************************************************** pmoabAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoabAlmLineUrg 40 } pmoabAlmLineBiasHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias High Alarm :This OID indicates that the Bias is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster bias is too high LINE_BIAS_HIGH_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 8 } pmoabAlmLineBiasLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias Low Alarm :This OID indicates that the Bias is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster bias is too low LINE_BIAS_LOW_ALARM pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 7 } pmoabAlmLineOutputPwrHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr High Alarm :This OID indicates that the Transmit Power is higher than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster tx power is too high LINE_OUTPUT_PWR_HIGH_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 6 } pmoabAlmLineOutputPwrLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr Low Alarm :This OID indicates that the Transmit Power is lower than the alarm theshold of the Booster Optical Module This alarm indicates if the Booster tx power is too low LINE_OUTPUT_PWR_LOW_ALARM transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 5 } pmoabAlmLineGainHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain High Alarm :This OID indicates that the Gain is higher than the alarm threshold of the Booster Module This alarm indicates if the Booster gain is too high LINE_GAIN_HIGH_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 2 } pmoabAlmLineGainLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain Low Alarm :This OID indicates that the Gain is lower than the alarm theshold of the Booster Module This alarm indicates if the Booster gain is too low LINE_GAIN_LOW_ALARM performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms1 1 } --- ***************************************************** --- LEAF for the lineEdfaWarnings article --- ***************************************************** pmoabAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoabAlmLineNurg 41 } pmoabAlmLineBiasHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias High Warning :This OID indicates that the Bias is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster bias is too high LINE_BIAS_HIGH_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 8 } pmoabAlmLineBiasLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Bias Low Warning :This OID indicates that the Bias is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster bias is too low LINE_BIAS_LOW_WARNING pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 7 } pmoabAlmLineOutputPwrHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr High Warning :This OID indicates that the Transmit Power is higher than the Warning theshold of the Booster Optical Module This warning indicates if the Booster tx power is too high LINE_OUTPUT_PWR_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 6 } pmoabAlmLineOutputPwrLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Pwr Low Warning :This OID indicates that the Transmit Power is lower than the Warning theshold of the Booster Optical Module This warning indicates if the Booster tx power is too low LINE_OUTPUT_PWR_LOW_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 5 } pmoabAlmLineGainHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain High Warning :This OID indicates that the Gain is higher than the Warning threshold of the Booster Module This alarm indicates if the Booster gain is too high LINE_GAIN_HIGH_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 2 } pmoabAlmLineGainLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain Low Warning :This OID indicates that the Gain is lower than the Warning theshold of the Booster Module This alarm indicates if the Booster gain is too low LINE_GAIN_LOW_WARNING performanceDegraded (35) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaWarnings 1 } --- ***************************************************** --- LEAF for the lineEdfaAlarms2 article --- ***************************************************** pmoabAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoabAlmLineCrit 43 } pmoabAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster External Pump1 Low Current :This OID indicates that the EDFA pump current of the first external pump linked to the Booster is too low This alarm indicates that the EDFA pump current of the first external pump linked to the Booster is too low. LINE_EXT_PUMP_EDFA_LOW_CURRENT pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms2 5 } pmoabAlmLineEdfaLaserFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Pump Laser Fail :This OID indicates a Transmit Laser Fail on the Booster Optical Module This alarm indicates if the laser of the Booster is in fail condition LINE_EDFA_LASER_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms2 3 } pmoabAlmLineEdfaTecFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster TEC Fail :This OID indicates that the TEC is in fail condition on the Booster Optical Module This alarm indicates if the TEC of the Booster is in fail condition LINE_EDFA_TEC_FAIL pumpFailure (39) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms2 2 } pmoabAlmLineEdfaNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Optical Module Not Ready :This OID indicates that the Booster Optical Module is not ready This status indicates if the Booster has been correctly initialized LINE_EDFA_NR equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmoabAlmlineEdfaAlarms2 1 } --- ***************************************************** --- LEAF for the foaAlarms article --- ***************************************************** pmoabAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoabAlmOtherUrg 74 } pmoabAlmTempHighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature High Alarm :This OID indicates that the PM temperature is higher than the alarm threshold TEMP_HIGH_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaAlarms 8 } pmoabAlmTermpLowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature Low Alarm :This OID indicates that the PM temperature if lower than the alarm threshold TERMP_LOW_ALARM temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaAlarms 7 } pmoabAlm3v3HighAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " 3V3 High Alarm :This OID indicates that the PM 3V3 voltage is higher than the alarm threshold 3V3_HIGH_ALARM powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaAlarms 6 } pmoabAlm3v3LowAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " 3V3 Low Alarm :This OID indicates that the PM 3V3 voltage is lower than the alarm threshold 3V3_LOW_ALARM powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaAlarms 5 } --- ***************************************************** --- LEAF for the foaWarnings article --- ***************************************************** pmoabAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoabAlmOtherNurg 75 } pmoabAlmTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature High Warning :This OID indicates that the PM temperature if higher than the Warning threshold TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaWarnings 8 } pmoabAlmTermpLowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Temperature Low Warning :This OID indicates that the PM temperature if lower than the Warning threshold TERMP_LOW_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaWarnings 7 } pmoabAlm3v3HighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " 3V3 High Warning :This OID indicates that the PM 3V3 voltage is higher than the Warning threshold 3V3_HIGH_WARNING powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaWarnings 6 } pmoabAlm3v3LowWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " 3V3 Low Warning :This OID indicates that the PM 3V3 voltage is lower than the Warning threshold 3V3_LOW_WARNING powerProblem (36) equipmentAlarm (5) (2) " ::= { pmoabAlmfoaWarnings 5 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmoabCtrlsynth0 OBJECT IDENTIFIER ::= { pmoabCtrlOther 0 } pmoabCtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmoabCtrlsynth0 13 } pmoabCtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmoabCtrlsynth0 9 } pmoabCtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmoabCtrlsynth0 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmoabCtrlswMgnt OBJECT IDENTIFIER ::= { pmoabCtrlOther 5 } pmoabCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmoabCtrlswMgnt 3 } pmoabCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmoabCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the lineEdfaLaserOff article --- ***************************************************** pmoabCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoabCtrlLine 40 } pmoabCtrlLineEdfaLaserOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Pump Laser Shutdown :This OID switches OFF the laser of the Booster Optical Module This control defines the laser state of the Booster " ::= { pmoabCtrllineEdfaLaserOff 1 } --- ***************************************************** --- LEAF for the lineEdfaMode article --- ***************************************************** pmoabCtrllineEdfaMode OBJECT-TYPE SYNTAX PmoabboosterMode MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Module Mode :This OID selects the mode of the Booster Module This control defines the Booster Mode (0: Default mode, 2:Constant output power) " ::= { pmoabCtrlLine 41 } --- ***************************************************** --- LEAF for the lineIlasSettingValue article --- ***************************************************** pmoabCtrllineIlasSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Laser Current Value :This OID sets the value of the laser current of the Booster Module (active only in constant current mode) (AV = Current *100) (Unit = mA) This control defines the Booster Laser current in mA (valid only in constant current mode) " ::= { pmoabCtrlLine 42 } --- ***************************************************** --- LEAF for the linePlasSettingValue article --- ***************************************************** pmoabCtrllinePlasSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Pump Power Value :This OID sets the value of the laser power of the Booster Optical Module (active only in constant power mode) (AV=(Power/0,005) + 32768) (Unit = dBm) This control defines the Booster laser power in dBm (valid only in constant output power mode) " ::= { pmoabCtrlLine 43 } --- ***************************************************** --- LEAF for the lineGainSettingValue article --- ***************************************************** pmoabCtrllineGainSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Gain Value :This OID sets the value of the gain of the Booster Module (active only in constant gain mode) (AV=(Gain/0,005) + 32768) (Unit = dB) " ::= { pmoabCtrlLine 44 } --- ***************************************************** --- LEAF for the lineEffPwrOutSettingValue article --- ***************************************************** pmoabCtrllineEffPwrOutSettingValue OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Booster Effective Output Power :This OID sets the value of the effective output power (without noise power) of the Booster Module (active only in input power function mode) (AV=(Power/0,005) + 32768) (Unit = dBm) " ::= { pmoabCtrlLine 45 } --- ***************************************************** --- LEAF for the powerDown article --- ***************************************************** pmoabCtrlpowerDown OBJECT IDENTIFIER ::= { pmoabCtrlOther 72 } pmoabCtrlSoftPowerDown OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Module Software Shutdown :This OID shuts down the PM Software This control initiates a shut down of software. " ::= { pmoabCtrlpowerDown 1 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmoabCtrlledTest OBJECT IDENTIFIER ::= { pmoabCtrlOther 73 } pmoabCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmoabCtrlledTest 3 } pmoabCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmoabCtrlledTest 2 } pmoabCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmoabCtrlledTest 1 } --- ***************************************************** --- LEAF for the maintMode article --- ***************************************************** pmoabCtrlmaintMode OBJECT IDENTIFIER ::= { pmoabCtrlOther 75 } pmoabCtrlMaintenance OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Module Maintenance Mode :This OID sets the PM in maintenance mode This control enables the maintenance mode of the module " ::= { pmoabCtrlmaintMode 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the clientEdfaRxpwrMeas article --- ***************************************************** pmoabMesrclientEdfaRxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Rx Power :This OID gives the receive power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Rx optical power of the Booster " ::= { pmoabMesrClient 34 } --- ***************************************************** --- LEAF for the lineEdfaBiasMeas article --- ***************************************************** pmoabMesrlineEdfaBiasMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Pump Laser Current :This OID gives the pump laser current of the Booster Optical Module (Current =AV/100) (Unit = mA) This measure gives the bias of the Booster pump laser " ::= { pmoabMesrLine 40 } --- ***************************************************** --- LEAF for the lineEdfaTxpwrMeas article --- ***************************************************** pmoabMesrlineEdfaTxpwrMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Tx Power :This OID gives the transmit power value of the Booster Optical Module (Power =(AV-32768)*0,005) (Unit = dBm) This measure gives the Tx optical power of the Booster " ::= { pmoabMesrLine 41 } --- ***************************************************** --- LEAF for the lineEdfaGainMeas article --- ***************************************************** pmoabMesrlineEdfaGainMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Booster Gain :This OID gives the gain value of the Booster Module (Gain =(AV-32768)*0,005) (Unit = dB) This measure gives the optical gain of the Booster " ::= { pmoabMesrLine 43 } --- ***************************************************** --- LEAF for the tempMeas article --- ***************************************************** pmoabMesrtempMeas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Module Temperature :This OID gives the temperature of the PM (Unit = C) This measure gives the temperature of the module " ::= { pmoabMesrOther 72 } --- ***************************************************** --- LEAF for the 3v3Meas article --- ***************************************************** pmoabMesr3v3Meas OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Module 3.3 Voltage :This OID gives the 3V3 voltage of the PM (Unit = V) This measure gives the 3V3 voltage of the module " ::= { pmoabMesrOther 73 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group noValue --- ***************************************************** pmoabCfgNoValue OBJECT IDENTIFIER ::= { pmoabConfig 1 } --- ***************************************************** --- LEAF for the table 2111 --- ***************************************************** pmoabtableclientStartup OBJECT IDENTIFIER ::= { pmoabCfgNoValue 1 } --- ***************************************************** --- LEAF for the table Group lineStartUp --- ***************************************************** pmoabCfgLineStartUp OBJECT IDENTIFIER ::= { pmoabConfig 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pmoabtablelineStartup OBJECT IDENTIFIER ::= { pmoabCfgLineStartUp 1 } pmoabCfglineEdfaLaserCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line Laser :This OID configures the default initialisation settings on the line laser. " ::= { pmoabtablelineStartup 2 } pmoabCfglineEdfaLaserMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line mode :This OID configures the default mode on the line amplifier. " ::= { pmoabtablelineStartup 3 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmoabCfgLabels OBJECT IDENTIFIER ::= { pmoabConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmoabCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmoabCfgLabels 1 } pmoabCfgLabelclientEntry OBJECT-TYPE SYNTAX PmoabCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmoabCfgLabelclientIndex } ::= { pmoabCfgLabelclientTable 1 } PmoabCfgLabelclientEntry ::= SEQUENCE { pmoabCfgLabelclientIndex INTEGER, pmoabCfgLabelclientPortn DisplayString } pmoabCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmoabCfgLabelclientEntry 1 } pmoabCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmoabCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmoabCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF PmoabCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmoabCfgLabels 2 } pmoabCfgLabellineEntry OBJECT-TYPE SYNTAX PmoabCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmoabCfgLabellineIndex } ::= { pmoabCfgLabellineTable 1 } PmoabCfgLabellineEntry ::= SEQUENCE { pmoabCfgLabellineIndex INTEGER, pmoabCfgLabellinePortn DisplayString } pmoabCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmoabCfgLabellineEntry 1 } pmoabCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmoabCfgLabellineEntry 3 } pmoabCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmoabConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmoabtrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmoabtraps 4 } --- ***************************************************** --- GLOBAL TRAPS --- ***************************************************** pmoabLineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmLineDdmWarning, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmoabAlmLineDdmWarning "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Warning appears on Booster Output of PMOA-B in slot $2 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pmoabtraps 30 } pmoabLineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmLineDdmWarning, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Line Not Urgent ON"} --&MATCH { pmoabAlmLineDdmWarning "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Booster Output of PMOA-B in slot $2 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pmoabtraps 31 } pmoabLineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmLineDdmAlm, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pmoabAlmLineDdmAlm "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Booster Output of PMOA-B in slot $2 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pmoabtraps 32 } pmoabLineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmLineDdmAlm, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Line Urgent ON"} --&MATCH { pmoabAlmLineDdmAlm "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Booster Output of PMOA-B in slot $2 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pmoabtraps 33 } pmoabLineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmLineFail, pmoabAlmLineHwFail, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pmoabAlmLineFail "on", pmoabAlmLineHwFail "*", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster Output of PMOA-B in slot $3 ($A)" --&FILTNAME "PMOAB Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmoabAlmLineFail "*", pmoabAlmLineHwFail "on", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster Output of PMOA-B in slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pmoabtraps 34 } pmoabLineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmLineFail, pmoabAlmLineHwFail, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Line Fail ON"} --&MATCH { pmoabAlmLineFail "on", pmoabAlmLineHwFail "*", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster Output of PMOA-B in slot $3 ($A)" --&FILTNAME "PMOAB Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmoabAlmLineFail "*", pmoabAlmLineHwFail "on", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster Output of PMOA-B in slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pmoabtraps 35 } --- ***************************************************** --- PORTS TRAPS --- ***************************************************** pmoabClientTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmClientDdmWarning, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmoabAlmClientDdmWarning "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Warning appears on Booster input of PMOA-B in slot $2 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pmoabtraps 40 } pmoabClientTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmClientDdmWarning, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Client Not Urgent ON"} --&MATCH { pmoabAlmClientDdmWarning "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Booster input of PMOA-B in slot $2 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pmoabtraps 41 } pmoabClientTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmClientDdmAlm, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Urgent ON" --&ACTIONS { log, major } --&MATCH { pmoabAlmClientDdmAlm "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Booster input of PMOA-B in slot $2 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pmoabtraps 42 } pmoabClientTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmClientDdmAlm, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Client Urgent ON"} --&MATCH { pmoabAlmClientDdmAlm "on", pmoabtrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Booster input of PMOA-B in slot $2 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pmoabtraps 43 } pmoabClientTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmClientFail, pmoabAlmClientHwFail, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Fail ON" --&ACTIONS { log, critical } --&MATCH { pmoabAlmClientFail "on", pmoabAlmClientHwFail "*", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster input of PMOA-B in slot $3 ($A)" --&FILTNAME "PMOAB Client HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmoabAlmClientFail "*", pmoabAlmClientHwFail "on", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm appears on Booster input of PMOA-B in slot $3 ($A)" DESCRIPTION "Critical client default is activated" ::= { pmoabtraps 44 } pmoabClientTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmClientFail, pmoabAlmClientHwFail, pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Client Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMOAB Client Fail ON"} --&MATCH { pmoabAlmClientFail "on", pmoabAlmClientHwFail "*", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster input of PMOA-B in slot $3 ($A)" --&FILTNAME "PMOAB Client HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmoabAlmClientFail "*", pmoabAlmClientHwFail "on", pmoabtrapBoardNumber "$3"} --&MESG "Critical Alarm disappears on Booster input of PMOA-B in slot $3 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pmoabtraps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmoabPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmoabAlmDefFuseB, pmoabAlmDefFuseA , pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmoabAlmDefFuseB "*", pmoabAlmDefFuseA "on", pmoabtrapBoardNumber "$3"} --&MESG "Power Input A Fail on PMOA-B in Slot $3 ($A)" --&FILTNAME "PMOAB Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmoabAlmDefFuseB "on", pmoabAlmDefFuseA "*", pmoabtrapBoardNumber "$3"} --&MESG "Power Input B Fail on PMOA-B in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmoabtraps 50 } pmoabPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmoabAlmDefFuseB, pmoabAlmDefFuseA , pmoabtrapBoardNumber} STATUS current --&FILTNAME "PMOAB Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMOAB Fuse A Fail ON", "PMOAB Fuse B Fail ON" } --&MATCH { pmoabAlmDefFuseB "on", pmoabAlmDefFuseA "on", pmoabtrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMOA-B in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmoabtraps 51 } END