-- ***************************************************************** -- EKINOPS-Pm1001RR.TXT: MIB -- --MIB Part Number:3MI00100AJAE --MIB Version:03 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-Pm1001RR-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePm1001RR MODULE-IDENTITY LAST-UPDATED "201606070000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "MIB for the Ekinops Pm1001RR hardware." REVISION "200512130000Z" DESCRIPTION "Initial Version." REVISION "200707020000Z" DESCRIPTION "Change °C to C." REVISION "200708280000Z" DESCRIPTION "Change Labels" REVISION "200711210000Z" DESCRIPTION "UPdate Ekinops address, Helps on objects, Ports Labels" REVISION "200802130000Z" DESCRIPTION "Adding OTX-TLH features" REVISION "200812040000Z" DESCRIPTION "Cosmetics for mib compilers" REVISION "200906110000Z" DESCRIPTION "CondType parameters insertion" REVISION "201001280000Z" DESCRIPTION "XFP-T and OTX-VLH parameters" REVISION "201002230000Z" DESCRIPTION "Probcause,AlarmType - NMS" REVISION "201003090000Z" DESCRIPTION "OTX-VLH-Reset" REVISION "201011030000Z" DESCRIPTION "Formula in comments, Event on XFP init" REVISION "201207040000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403250000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201501140000Z" DESCRIPTION "Add Loopback objects" REVISION "201501140000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" REVISION "201606070000Z" DESCRIPTION "Capabilities objects of Table 5" ::= { ekinops 8 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pm1001rralarms OBJECT IDENTIFIER ::= { modulePm1001RR 2 } pm1001rrAlmOther OBJECT IDENTIFIER ::= { pm1001rralarms 1 } pm1001rrAlmOtherNurg OBJECT IDENTIFIER ::= { pm1001rrAlmOther 1 } pm1001rrAlmOtherUrg OBJECT IDENTIFIER ::= { pm1001rrAlmOther 2 } pm1001rrAlmOtherCrit OBJECT IDENTIFIER ::= { pm1001rrAlmOther 3 } pm1001rrAlmClient OBJECT IDENTIFIER ::= { pm1001rralarms 2 } pm1001rrAlmClientNurg OBJECT IDENTIFIER ::= { pm1001rrAlmClient 1 } pm1001rrAlmClientUrg OBJECT IDENTIFIER ::= { pm1001rrAlmClient 2 } pm1001rrAlmClientCrit OBJECT IDENTIFIER ::= { pm1001rrAlmClient 3 } pm1001rrAlmLine OBJECT IDENTIFIER ::= { pm1001rralarms 3 } pm1001rrAlmLineNurg OBJECT IDENTIFIER ::= { pm1001rrAlmLine 1 } pm1001rrAlmLineUrg OBJECT IDENTIFIER ::= { pm1001rrAlmLine 2 } pm1001rrAlmLineCrit OBJECT IDENTIFIER ::= { pm1001rrAlmLine 3 } pm1001rrmeasures OBJECT IDENTIFIER ::= { modulePm1001RR 3 } pm1001rrMesrOther OBJECT IDENTIFIER ::= { pm1001rrmeasures 1 } pm1001rrMesrClient OBJECT IDENTIFIER ::= { pm1001rrmeasures 2 } pm1001rrMesrLine OBJECT IDENTIFIER ::= { pm1001rrmeasures 3 } pm1001rrcontrolsWrite OBJECT IDENTIFIER ::= { modulePm1001RR 6 } pm1001rrCtrlOther OBJECT IDENTIFIER ::= { pm1001rrcontrolsWrite 1 } pm1001rrCtrlClient OBJECT IDENTIFIER ::= { pm1001rrcontrolsWrite 2 } pm1001rrCtrlLine OBJECT IDENTIFIER ::= { pm1001rrcontrolsWrite 3 } pm1001rrri OBJECT IDENTIFIER ::= { modulePm1001RR 7 } pm1001rrConfig OBJECT IDENTIFIER ::= { modulePm1001RR 9 } pm1001rrtraps OBJECT IDENTIFIER ::= { modulePm1001RR 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** Pm1001rrBitRate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "different rates for a client and line ports" SYNTAX INTEGER { rateOC192(0), rate10GBELAN(1), rate10GBEWAN(2), rate10GFC(3), rate10FECG975(4), rate10FECG709(5), rate10DYNAFEC(6) } Pm1001rrOtxMode ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different modes on OTX-TLH on client and line ports" SYNTAX INTEGER { otx80mode(1), otx60mode(2), otxadjustmode(4) } Pm1001rrOtxGrid ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different grids on OTX-TLH on client and line ports" SYNTAX INTEGER { otxgrid200(200), otxgrid100(100), otxgrid50(50) } Pm1001rrAdjustValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Different values in Adjust mode on OTX-TLH on client and line ports" SYNTAX INTEGER { otxadjustvalue0(0), otxadjustvalue1(1), otxadjustvalue2(2), otxadjustvalue3(3), otxadjustvalue4(4), otxadjustvalue5(5), otxadjustvalue6(6), otxadjustvalue7(7), otxadjustvalue8(8), otxadjustvalue9(9), otxadjustvalue10(10) } Pm1001rrOtxChannel ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Channel selection on OTX-TLH on client and line ports" SYNTAX INTEGER --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pm1001rrRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pm1001rrri 2 } pm1001rrRinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pm1001rrri 4 } pm1001rrRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pm1001rrri 5 } pm1001rrRinvClientXFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the XFP: This OID contains the inventory for the Client XFP" ::= { pm1001rrri 6 } pm1001rrRinvLineXFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the XFP: This OID contains the inventory for the Line XFP" ::= { pm1001rrri 7 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pm1001rrAlmsynthAlm0 OBJECT IDENTIFIER ::= { pm1001rrAlmOtherCrit 0 } pm1001rrAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm0 16 } pm1001rrAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm0 15 } pm1001rrAlmModuleGlobFailure OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MODULE_GLOB_FAILURE equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm7 article --- ***************************************************** pm1001rrAlmsynthAlm7 OBJECT IDENTIFIER ::= { pm1001rrAlmLineCrit 7 } pm1001rrAlmLineVccAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 VCC Alarm :This OID indicates an overall VCC alarm is set over the Line 2 XFP LINE_VCC_ALARM powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm7 15 } pm1001rrAlmLineVccWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 VCC Warning :This OID indicates an overall VCC warning is set over the Line 2 XFP LINE_VCC_WARNING powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm7 14 } pm1001rrAlmLineFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Port Failure :This OID indicates a failure on the Line 2 port LINE_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm7 12 } pm1001rrAlmLineDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line 2 Optical Module DDM :This OID indicates an alarm is present coming out of Line 2 optical interface DDM This alarm indicates if a DDM Alarm has been detected on the line 2 transceiver LINE_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm7 10 } pm1001rrAlmLineDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line 2 Optical Module DDM :This OID indicates a warning is present coming out of Line 2 optical interface DDM This alarm indicates if a DDM Warning has been detected on the line 2 transceiver LINE_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm7 9 } pm1001rrAlmLineXfpTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Laser Shutdown :This OID indicates the Line 2 optical output power is off This status indicates if the line 2 transceiver laser is ON or OFF LINE_XFP_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm7 5 } pm1001rrAlmLineHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Port HW Failure :This OID indicates a failure on Line 2 port, most probably caused by a HW issue LINE_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm7 4 } pm1001rrAlmLineInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Ready :This OID indicates the optical interface (XFP or OTX) is not operational This status indicates if the line 2 transceiver has been correctly initialized LINE_INIT_NOT_COMPL equipmentMalfunction (16) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001rrAlmsynthAlm7 2 } pm1001rrAlmLineXfpAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Absent :This OID indicates the Line 2 optical interface (XFP or OTX) is not present in the PM This alarm indicates if the line 2 transceiver is present. LINE_XFP_ABSENT inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001rrAlmsynthAlm7 1 } --- ***************************************************** --- LEAF for the synthAlm8 article --- ***************************************************** pm1001rrAlmsynthAlm8 OBJECT IDENTIFIER ::= { pm1001rrAlmClientCrit 8 } pm1001rrAlmClientVccAlarm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 VCC Alarm :This OID indicates an overall VCC alarm is set over the Line 1 XFP CLIENT_VCC_ALARM powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm8 15 } pm1001rrAlmClientVccWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1VCC Warning :This OID indicates an overall VCC warning is set over the Line 1 XFP CLIENT_VCC_WARNING powerProblem (36) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm8 14 } pm1001rrAlmClientFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Port Failure :This OID indicates a failure on the Line 1 port CLIENT_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm8 12 } pm1001rrAlmClientDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm On Line 1 Optical Module DDM :This OID indicates an alarm is present coming out of Line 1 optical interface DDM This alarm indicates if a DDM Alarm has been detected on the line 1 transceiver CLIENT_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm8 10 } pm1001rrAlmClientDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning On Line 1 Optical Module DDM :This OID indicates a warning is present coming out of Line 1 optical interface DDM This alarm indicates if a DDM Warning has been detected on the line 1 transceiver CLIENT_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm8 9 } pm1001rrAlmClientXfpTxOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Laser Shutdown :This OID indicates the Line 1 optical output power is off This status indicates if the line 1 transceiver laser is ON or OFF CLIENT_XFP_TX_OFF other (1) equipmentAlarm (5) (2) " ::= { pm1001rrAlmsynthAlm8 5 } pm1001rrAlmClientHwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Port HW Failure :This OID indicates a failure on Line 1 port, most probably caused by a HW issue. CLIENT_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pm1001rrAlmsynthAlm8 4 } pm1001rrAlmClientInitNotCompl OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Ready :This OID indicates the optical interface (XFP or OTX) is not operational This status indicates if the line 1 transceiver has been correctly initialized CLIENT_INIT_NOT_COMPL equipmentMalfunction (16) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001rrAlmsynthAlm8 2 } pm1001rrAlmClientXfpAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Absent :This OID indicates the Line 1 optical interface (XFP or OTX) is not present in the PM This alarm indicates if the line 1 transceiver is present. CLIENT_XFP_ABSENT inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pm1001rrAlmsynthAlm8 1 } --- ***************************************************** --- LEAF for the clientXfpAlarm1 article --- ***************************************************** pm1001rrAlmclientXfpAlarm1 OBJECT IDENTIFIER ::= { pm1001rrAlmClientUrg 16 } pm1001rrAlmClientRxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx Power High :Alarm indicating that the Line 1 XFP/OTX received optical power is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_RX_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 16 } pm1001rrAlmClientRxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx Power Low :Alarm indicating that the Line 1 XFP/OTX received optical power is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_RX_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 15 } pm1001rrAlmClientTempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Temp High :Alarm indicating that the Line 1 XFP/OTX temperature is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 8 } pm1001rrAlmClientTempLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Temp Low :Alarm indicating that the Line 1 XFP/OTX temperature is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TEMP_LOW_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 7 } pm1001rrAlmClientTxBiasHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Bias High :Alarm indicating that the Line 1 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_BIAS_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 4 } pm1001rrAlmClientTxBiasLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Bias Low :Alarm indicating that the Line 1 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_BIAS_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 3 } pm1001rrAlmClientTxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Power High :Alarm indicating that the Line 1 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 2 } pm1001rrAlmClientTxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Power Low :Alarm indicating that the Line 1 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarm1 1 } --- ***************************************************** --- LEAF for the clientXfpWarnings article --- ***************************************************** pm1001rrAlmclientXfpWarnings OBJECT IDENTIFIER ::= { pm1001rrAlmClientNurg 17 } pm1001rrAlmClientRxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx Power High Warning :Warning indicating that the Line 1 XFP/OTX received optical power is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_RX_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 16 } pm1001rrAlmClientRxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx Power Low Warning :Warning indicating that the Line 1 XFP/OTX received optical power is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_RX_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 15 } pm1001rrAlmClientTempHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Temp High Warning :Warning indicating that the Line 1 XFP/OTX temperature is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TEMP_HIGH_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 8 } pm1001rrAlmClientTempLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Temp Low Warning :Warning indicating that the Line 1 XFP/OTX temperature is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TEMP_LOW_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 7 } pm1001rrAlmClientTxBiasHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Bias High Warning :Warning indicating that the Line 1 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_BIAS_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 4 } pm1001rrAlmClientTxBiasLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Transceiver Bias Low Warning :Warning indicating that the Line 1 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_BIAS_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 3 } pm1001rrAlmClientTxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Power High Warning :Warning indicating that the Line 1 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 2 } pm1001rrAlmClientTxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Power Low Warning :Warning indicating that the Line 1 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Line 1 XFP/OTX EEPROM CLIENT_TX_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpWarnings 1 } --- ***************************************************** --- LEAF for the clientXfpAlarms2 article --- ***************************************************** pm1001rrAlmclientXfpAlarms2 OBJECT IDENTIFIER ::= { pm1001rrAlmClientCrit 19 } pm1001rrAlmClientApdSupplyFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Rx Photodiode Power Failed :This OID indicates a failure on the Line 1 APD power supply CLIENT_APD_SUPPLY_FAULT receiverFailure (42) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 16 } pm1001rrAlmClientTecFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Temp Regul. Failed :This OID indicates a failure on the Line 1 TEC module CLIENT_TEC_FAULT transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 15 } pm1001rrAlmClientWavelengthUnlocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Wavelength Unlocked :This OID indicates that the Line 1 wavelength error is exceeding the manufacturer tolerance CLIENT_WAVELENGTH_UNLOCKED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 14 } pm1001rrAlmClientChannelNotAcquired OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. This status indicates the transceiver has not tuned the DWDM Channel succesfully. CLIENT_CHANNEL_NOT_ACQUIRED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 10 } pm1001rrAlmClientTxNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the Line 1 transmitting side CLIENT_TX_NR transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 8 } pm1001rrAlmClientTxFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx Failure :This OID indicates a fault condition on the Line 1 laser detected by the safety syste CLIENT_TX_FAULT transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 7 } pm1001rrAlmClientTxCdrNotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Tx CDR Unlocked :This OID indicates a loss of lock on the Line 1 transmitting side CDR has been detected. CLIENT_TX_CDR_NOT_LOCKED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 6 } pm1001rrAlmClientRxNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the Line 1 receiving side. CLIENT_RX_NR receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 5 } pm1001rrAlmClientRxLos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Loss Of Optical Signal :This bit indicates an absence of signal on the XFP/OTX This alarm indicates if an optical signal is detected on the line 1 transceiver input CLIENT_RX_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pm1001rrAlmclientXfpAlarms2 4 } pm1001rrAlmClientRxCdrNotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the Line 1 receiving side CDR has been detected CLIENT_RX_CDR_NOT_LOCKED receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientXfpAlarms2 3 } pm1001rrAlmClientResetComplete OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This bit indicates that the internal reset process is completed and the data are available CLIENT_RESET_COMPLETE other (1) other (1) (2) " ::= { pm1001rrAlmclientXfpAlarms2 1 } --- ***************************************************** --- LEAF for the clientOtxTlhAlarms3 article --- ***************************************************** pm1001rrAlmclientOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm1001rrAlmClientUrg 22 } pm1001rrAlmClientLaserTempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Laser Temp. High Alarm :Alarm indicating the Line 1 OTX TLH laser temperature is higher than the threshold written in the EEPROM CLIENT_LASER_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhAlarms3 14 } pm1001rrAlmClientFreqDevHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Freq. Deviation High Alarm :Alarm indicating the Line 1 OTX TLH frequency deviation is higher than the threshold written in the EEPROM CLIENT_FREQ_DEV_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhAlarms3 12 } pm1001rrAlmClientCdrNotReady OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized This alarm indicates the Clock Data Recovery unit is not yet initialized. CLIENT_CDR_NOT_READY receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhAlarms3 9 } pm1001rrAlmClientAgingHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 OTX TLH Aging High Alarm :Alarm indicating the Line 1 OTX TLH aging is higher than the threshold written in the EEPROM CLIENT_AGING_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhAlarms3 6 } pm1001rrAlmClientModulatorAgingHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Modulator Aging High Alarm :Alarm indicating the Line 1 OTX TLH modulator aging is higher than the threshold written in the EEPROM CLIENT_MODULATOR_AGING_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhAlarms3 5 } --- ***************************************************** --- LEAF for the clientOtxTlhWarnings article --- ***************************************************** pm1001rrAlmclientOtxTlhWarnings OBJECT IDENTIFIER ::= { pm1001rrAlmClientNurg 23 } pm1001rrAlmClientLaserTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Laser Temp. High Warning :Warning indicating the Line 1 OTX TLH laser temperature is higher than the threshold written in the EEPROM CLIENT_LASER_TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhWarnings 14 } pm1001rrAlmClientFreqDevHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Freq. Deviation High Warning :Warning indicating the Line 1 OTX TLH frequency deviation is higher than the threshold written in the EEPROM CLIENT_FREQ_DEV_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhWarnings 12 } pm1001rrAlmClientAgingHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 OTX TLH Aging High Warning :Warning indicating the Line 1 OTX TLH aging is higher than the threshold written in the EEPROM CLIENT_AGING_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhWarnings 6 } pm1001rrAlmClientModulatorAgingHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Modulator Aging High Warning :Warning indicating the Line 1 OTX TLH modulator aging is higher than the threshold written in the EEPROM CLIENT_MODULATOR_AGING_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmclientOtxTlhWarnings 5 } --- ***************************************************** --- LEAF for the lineXfpAlarm1 article --- ***************************************************** pm1001rrAlmlineXfpAlarm1 OBJECT IDENTIFIER ::= { pm1001rrAlmLineUrg 24 } pm1001rrAlmLineRxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx Power High :Alarm indicating that the Line 2 XFP/OTX received optical power is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_RX_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 16 } pm1001rrAlmLineRxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx Power Low :Alarm indicating that the Line 2 XFP/OTX received optical power is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_RX_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 15 } pm1001rrAlmLineTempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Temp High :Alarm indicating that the Line 2 XFP/OTX temperature is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 8 } pm1001rrAlmLineTempLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Temp Low :Alarm indicating that the Line 2 XFP/OTX temperature is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TEMP_LOW_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 7 } pm1001rrAlmLineTxBiasHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Bias High :Alarm indicating that the Line 2 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_BIAS_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 4 } pm1001rrAlmLineTxBiasLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Bias Low :Alarm indicating that the Line 2 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_BIAS_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 3 } pm1001rrAlmLineTxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Power High :Alarm indicating that the Line 2 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 2 } pm1001rrAlmLineTxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Power Low :Alarm indicating that the Line 2 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarm1 1 } --- ***************************************************** --- LEAF for the lineXfpWarnings article --- ***************************************************** pm1001rrAlmlineXfpWarnings OBJECT IDENTIFIER ::= { pm1001rrAlmLineNurg 25 } pm1001rrAlmLineRxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx Power High Warning :Warning indicating that the Line 2 XFP/OTX received optical power is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_RX_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 16 } pm1001rrAlmLineRxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx Power Low Warning :Warning indicating that the Line 2 XFP/OTX received optical power is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_RX_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 15 } pm1001rrAlmLineTempHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Temp High Warning :Warning indicating that the Line 2 XFP/OTX temperature is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TEMP_HIGH_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 8 } pm1001rrAlmLineTempLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Temp Low Warning :Warning indicating that the Line 2 XFP/OTX temperature is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TEMP_LOW_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 7 } pm1001rrAlmLineTxBiasHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Bias High Warning :Warning indicating that the Line 2 XFP/OTX transmitter laser bias current is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_BIAS_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 4 } pm1001rrAlmLineTxBiasLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Transceiver Bias Low Warning :Warning indicating that the Line 2 XFP/OTX transmitter laser bias current is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_BIAS_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 3 } pm1001rrAlmLineTxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Power High Warning :Warning indicating that the Line 2 XFP/OTX transmitter transmitter output power is higher than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 2 } pm1001rrAlmLineTxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Power Low Warning :Warning indicating that the Line 2 XFP/OTX transmitter transmitter output power is lower than the threshold value written in the Line 2 XFP/OTX EEPROM LINE_TX_PWR_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpWarnings 1 } --- ***************************************************** --- LEAF for the lineXfpAlarms2 article --- ***************************************************** pm1001rrAlmlineXfpAlarms2 OBJECT IDENTIFIER ::= { pm1001rrAlmLineCrit 27 } pm1001rrAlmLineApdSupplyFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Rx Photodiode Power Failed :This OID indicates a failure on the Line 2 APD power supply LINE_APD_SUPPLY_FAULT receiverFailure (42) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 16 } pm1001rrAlmLineTecFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Temp Regul. Failed :This OID indicates a failure on the Line 2 TEC module LINE_TEC_FAULT transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 15 } pm1001rrAlmLineWavelengthUnlocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Wavelength Unlocked :This OID indicates that the Line 2 wavelength error is exceeding the manufacturer tolerance LINE_WAVELENGTH_UNLOCKED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 14 } pm1001rrAlmLineChannelNotAcquired OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 DWDM Channel Not Acquired :This OID indicates the transceiver didn't tune the DWDM Channel succesfully. This status indicates the transceiver has not tuned the DWDM Channel succesfully. LINE_CHANNEL_NOT_ACQUIRED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 10 } pm1001rrAlmLineTxNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Not Ready :This OID indicates a condition has arisen leading to invalid data on the Line 2 transmitting side LINE_TX_NR transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 8 } pm1001rrAlmLineTxFault OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx Failure :This OID indicates a fault condition on the Line 2 laser detected by the safety syste LINE_TX_FAULT transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 7 } pm1001rrAlmLineTxCdrNotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Tx CDR Unlocked :This OID indicates a loss of lock on the Line 2 transmitting side CDR has been detected. LINE_TX_CDR_NOT_LOCKED transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 6 } pm1001rrAlmLineRxNr OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx Not Ready :This OID indicates that a condition has arisen leading to invalid data on the Line 2 receiving side. LINE_RX_NR receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 5 } pm1001rrAlmLineRxLos OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Loss Of Optical Signal :This bit indicates an absence of signal on the XFP/OTX This alarm indicates if an optical signal is detected on the line 2 transceiver input LINE_RX_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pm1001rrAlmlineXfpAlarms2 4 } pm1001rrAlmLineRxCdrNotLocked OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Rx CDR Unlocked :This OID indicates that a loss of lock on the Line 2 receiving side CDR has been detected LINE_RX_CDR_NOT_LOCKED receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmlineXfpAlarms2 3 } pm1001rrAlmLineResetComplete OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Not Used :This bit indicates that the internal reset process is completed and the data are available LINE_RESET_COMPLETE other (1) other (1) (2) " ::= { pm1001rrAlmlineXfpAlarms2 1 } --- ***************************************************** --- LEAF for the rrLineOtxTlhAlarms3 article --- ***************************************************** pm1001rrAlmrrLineOtxTlhAlarms3 OBJECT IDENTIFIER ::= { pm1001rrAlmLineUrg 30 } pm1001rrAlmLineLaserTempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Laser Temp. High Alarm :Alarm indicating the Line 2 OTX TLH laser temperature is higher than the threshold written in the EEPROM LINE_LASER_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhAlarms3 14 } pm1001rrAlmLineFreqDevHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Freq. Deviation High Alarm :Alarm indicating the Line 2 OTX TLH frequency deviation is higher than the threshold written in the EEPROM LINE_FREQ_DEV_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhAlarms3 12 } pm1001rrAlmLineCdrNotReady OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 CDR Not Ready :This OID indicates the Clock Data Recovery unit is not yet initialized This alarm indicates the Clock Data Recovery unit is not yet initialized. LINE_CDR_NOT_READY receiveFailure (41) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhAlarms3 9 } pm1001rrAlmLineAgingHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 OTX TLH Aging High Alarm :Alarm indicating the Line 2 OTX TLH aging is higher than the threshold written in the EEPROM LINE_AGING_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhAlarms3 6 } pm1001rrAlmLineModulatorAgingHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Modulator Aging High Alarm :Alarm indicating the Line 2 OTX TLH modulator aging is higher than the threshold written in the EEPROM LINE_MODULATOR_AGING_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhAlarms3 5 } --- ***************************************************** --- LEAF for the rrLineOtxTlhWarnings article --- ***************************************************** pm1001rrAlmrrLineOtxTlhWarnings OBJECT IDENTIFIER ::= { pm1001rrAlmLineNurg 31 } pm1001rrAlmLineLaserTempHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Laser Temp. High Warning :Warning indicating the Line 2 OTX TLH laser temperature is higher than the threshold written in the EEPROM LINE_LASER_TEMP_HIGH_WARNING temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhWarnings 14 } pm1001rrAlmLineFreqDevHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Freq. Deviation High Warning :Warning indicating the Line 2 OTX TLH frequency deviation is higher than the threshold written in the EEPROM LINE_FREQ_DEV_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhWarnings 12 } pm1001rrAlmLineAgingHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 OTX TLH Aging High Warning :Warning indicating the Line 2 OTX TLH aging is higher than the threshold written in the EEPROM LINE_AGING_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhWarnings 6 } pm1001rrAlmLineModulatorAgingHighWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Modulator Aging High Warning :Warning indicating the Line 2 OTX TLH modulator aging is higher than the threshold written in the EEPROM LINE_MODULATOR_AGING_HIGH_WARNING transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pm1001rrAlmrrLineOtxTlhWarnings 5 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pm1001rrCtrlsynth0 OBJECT IDENTIFIER ::= { pm1001rrCtrlOther 0 } pm1001rrCtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pm1001rrCtrlsynth0 13 } pm1001rrCtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pm1001rrCtrlsynth0 9 } pm1001rrCtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pm1001rrCtrlsynth0 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pm1001rrCtrlsynth4 OBJECT IDENTIFIER ::= { pm1001rrCtrlOther 4 } pm1001rrCtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM " ::= { pm1001rrCtrlsynth4 2 } pm1001rrCtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM " ::= { pm1001rrCtrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pm1001rrCtrlswMgnt OBJECT IDENTIFIER ::= { pm1001rrCtrlOther 5 } pm1001rrCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Software Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pm1001rrCtrlswMgnt 3 } pm1001rrCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Software Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pm1001rrCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the clientXfpOnoff article --- ***************************************************** pm1001rrCtrlclientXfpOnoff OBJECT IDENTIFIER ::= { pm1001rrCtrlClient 16 } pm1001rrCtrlClientXfpOnoff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 1 Optical Laser Shutdown :This OID switches off the Line 1 XFP/OTX This control defines the laser state of the line 1 transceiver " ::= { pm1001rrCtrlclientXfpOnoff 1 } --- ***************************************************** --- LEAF for the clientXfpLineLoop article --- ***************************************************** pm1001rrCtrlclientXfpLineLoop OBJECT IDENTIFIER ::= { pm1001rrCtrlClient 17 } pm1001rrCtrlClientXfpLineLoop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 1 Facility Loopback :This OID operates a Line 1 Facility Loopback, looping line 1 input signal on the line 1 output port. The loop is located on the line 1 transceiver This maintenance parameter operates a Line 1 Facility Loopback, looping line 1 input signal on the line 1 output port. The loop is located on the line 1 transceiver " ::= { pm1001rrCtrlclientXfpLineLoop 1 } --- ***************************************************** --- LEAF for the clientXfiLoop article --- ***************************************************** pm1001rrCtrlclientXfiLoop OBJECT IDENTIFIER ::= { pm1001rrCtrlClient 18 } pm1001rrCtrlClientXfiLoop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 1 Terminal Loopback :This OID operates a Line 1 Terminal Loopback, looping line 2 input signal on the line 2 output port. The loop is located on the line 1 transceiver This maintenance parameter operates a Line 1 Terminal Loopback, looping line 2 input signal on the line 2 output port. The loop is located on the line 1 transceiver " ::= { pm1001rrCtrlclientXfiLoop 1 } --- ***************************************************** --- LEAF for the clientTunableChannel article --- ***************************************************** pm1001rrCtrlclientTunableChannel OBJECT-TYPE SYNTAX Pm1001rrOtxChannel MAX-ACCESS read-write STATUS current DESCRIPTION " ITU Channel :This OID selects the ITU channel of the Line 1 OTX TLH Laser This control defines the ITU channel of the Line 1 OTX TLH Laser " ::= { pm1001rrCtrlClient 19 } --- ***************************************************** --- LEAF for the clientPhotodiodeMode article --- ***************************************************** pm1001rrCtrlclientPhotodiodeMode OBJECT-TYPE SYNTAX Pm1001rrOtxMode MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line 1 OTX TLH This control defines the receiver sensibility mode of the Line 1 OTX TLH Laser (OTX60, OTX80 or Custom) " ::= { pm1001rrCtrlClient 20 } --- ***************************************************** --- LEAF for the clientPhotodiodeValue article --- ***************************************************** pm1001rrCtrlclientPhotodiodeValue OBJECT-TYPE SYNTAX Pm1001rrAdjustValue MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line 1 OTX TLH (custom mode only) This control defines the receiver sensibility value (only in Custom mode) of the Line 1 OTX TLH Laser " ::= { pm1001rrCtrlClient 21 } --- ***************************************************** --- LEAF for the clientPowerLaser article --- ***************************************************** pm1001rrCtrlclientPowerLaser OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line 1 OTX TLH (AV=Power*10+158) (Unit = dBm) This control defines the start-up output power of the Line 1 OTX TLH " ::= { pm1001rrCtrlClient 22 } --- ***************************************************** --- LEAF for the clientOtxVlhReset article --- ***************************************************** pm1001rrCtrlclientOtxVlhReset OBJECT IDENTIFIER ::= { pm1001rrCtrlLine 23 } pm1001rrCtrlClientOtxVlhReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 1 OTX-VLH Reset :This OID resets the OTX-VLH module This control resets the OTX-TLH and its parameters " ::= { pm1001rrCtrlclientOtxVlhReset 1 } --- ***************************************************** --- LEAF for the lineXfpOnoff article --- ***************************************************** pm1001rrCtrllineXfpOnoff OBJECT IDENTIFIER ::= { pm1001rrCtrlLine 24 } pm1001rrCtrlLineXfpOnoff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 2 Optical Laser Shutdown :This OID switches off the Line 2 XFP/OTX This control defines the laser state of the line 2 transceiver " ::= { pm1001rrCtrllineXfpOnoff 1 } --- ***************************************************** --- LEAF for the lineXfpLineLoop article --- ***************************************************** pm1001rrCtrllineXfpLineLoop OBJECT IDENTIFIER ::= { pm1001rrCtrlLine 25 } pm1001rrCtrlLineXfpLineLoop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 2 Facility Loopback :This OID operates a Line 2 Facility Loopback, looping line 2 input signal on the line 2 output port. The loop is located on the line 2 transceiver. If the Line signal carries DCC, the management network is impacted This maintenance parameter operates a Line 2 Facility Loopback, looping line 2 input signal on the line 2 output port. The loop is located on the line 2 transceiver. If the Line signal carries DCC, the management network is impacted " ::= { pm1001rrCtrllineXfpLineLoop 1 } --- ***************************************************** --- LEAF for the lineXfiLoop article --- ***************************************************** pm1001rrCtrllineXfiLoop OBJECT IDENTIFIER ::= { pm1001rrCtrlLine 26 } pm1001rrCtrlLineXfiLoop OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 2 Terminal Loopback :This OID operates a Line 2 Terminal Loopback, looping line 1 input signal on the line 1 output port. The loop is located on the line 2 transceiver This maintenance parameter operates a Line 2 Terminal Loopback, looping line 1 input signal on the line 1 output port. The loop is located on the line 2 transceiver " ::= { pm1001rrCtrllineXfiLoop 1 } --- ***************************************************** --- LEAF for the lineTunableChannel article --- ***************************************************** pm1001rrCtrllineTunableChannel OBJECT-TYPE SYNTAX Pm1001rrOtxChannel MAX-ACCESS read-write STATUS current DESCRIPTION " ITU Channel :This OID selects the ITU channel of the Line 2 OTX TLH Laser This control defines the ITU channel of the Line 2 OTX TLH Laser " ::= { pm1001rrCtrlLine 27 } --- ***************************************************** --- LEAF for the linePhotodiodeMode article --- ***************************************************** pm1001rrCtrllinePhotodiodeMode OBJECT-TYPE SYNTAX Pm1001rrOtxMode MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sens. Mode :This OID defines the Rx sensiblity mode of the Line 2 OTX TLH This control defines the receiver sensibility mode of the Line 2 OTX TLH Laser (OTX60, OTX80 or Custom) " ::= { pm1001rrCtrlLine 28 } --- ***************************************************** --- LEAF for the linePhotodiodeValue article --- ***************************************************** pm1001rrCtrllinePhotodiodeValue OBJECT-TYPE SYNTAX Pm1001rrAdjustValue MAX-ACCESS read-write STATUS current DESCRIPTION " OTX TLH Rx Sensibility :This OID sets the Rx sensibility of the Line 2 OTX TLH (custom mode only) This control defines the receiver sensibility value (only in Custom mode) of the Line 2 OTX TLH Laser " ::= { pm1001rrCtrlLine 29 } --- ***************************************************** --- LEAF for the linePowerLaser article --- ***************************************************** pm1001rrCtrllinePowerLaser OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION " Laser Output Power [3-5] :This OID sets the output power value on the laser of the Line 2 OTX TLH (AV=Power*10+158) (Unit = dBm) This control defines the start-up output power of the Line 2 OTX TLH " ::= { pm1001rrCtrlLine 30 } --- ***************************************************** --- LEAF for the lineOtxVlhReset article --- ***************************************************** pm1001rrCtrllineOtxVlhReset OBJECT IDENTIFIER ::= { pm1001rrCtrlLine 31 } pm1001rrCtrlLineOtxVlhReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 2 OTX-VLH Reset :This OID resets the OTX-VLH module This control resets the OTX-TLH and its parameters " ::= { pm1001rrCtrllineOtxVlhReset 1 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pm1001rrCtrlledTest OBJECT IDENTIFIER ::= { pm1001rrCtrlOther 64 } pm1001rrCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pm1001rrCtrlledTest 3 } pm1001rrCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pm1001rrCtrlledTest 2 } pm1001rrCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pm1001rrCtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the clientTemperature article --- ***************************************************** pm1001rrMesrclientTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Temperature :This OID gives the temperature of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the temperature of the line 1 transceiver " ::= { pm1001rrMesrClient 16 } --- ***************************************************** --- LEAF for the clientTxBias article --- ***************************************************** pm1001rrMesrclientTxBias OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 XFP/OTX Tx Bias Current :This OID gives the bias value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This measure gives the bias of the line 1 transceiver " ::= { pm1001rrMesrClient 18 } --- ***************************************************** --- LEAF for the clientTxPower article --- ***************************************************** pm1001rrMesrclientTxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Tx Power :This OID gives the transmit power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Tx optical power of the line 1 transceiver " ::= { pm1001rrMesrClient 19 } --- ***************************************************** --- LEAF for the clientRxPower article --- ***************************************************** pm1001rrMesrclientRxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Rx Power :This OID gives the receive power value of the Client XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Rx optical power of the line 1 transceiver " ::= { pm1001rrMesrClient 20 } --- ***************************************************** --- LEAF for the lineTemperature article --- ***************************************************** pm1001rrMesrlineTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Temperature :This OID gives the temperature of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the temperature of the line 2 transceiver " ::= { pm1001rrMesrLine 24 } --- ***************************************************** --- LEAF for the lineTxBias article --- ***************************************************** pm1001rrMesrlineTxBias OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 XFP/OTX Tx Bias Current :This OID gives the bias value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This measure gives the bias of the line 2 transceiver " ::= { pm1001rrMesrLine 26 } --- ***************************************************** --- LEAF for the lineTxPower article --- ***************************************************** pm1001rrMesrlineTxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Tx Power :This OID gives the transmit power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Tx optical power of the line 2 transceiver " ::= { pm1001rrMesrLine 27 } --- ***************************************************** --- LEAF for the lineRxPower article --- ***************************************************** pm1001rrMesrlineRxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Rx Power :This OID gives the receive power value of the Line XFP/OTX, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Rx optical power of the line 2 transceiver " ::= { pm1001rrMesrLine 28 } --- ***************************************************** --- LEAF for the clientAging article --- ***************************************************** pm1001rrMesrclientAging OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 OTX TLH Aging :This OID gives the aging of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) This measure gives the aging of the line 1 OTX TLH " ::= { pm1001rrMesrClient 32 } --- ***************************************************** --- LEAF for the clientLaserTemperature article --- ***************************************************** pm1001rrMesrclientLaserTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 OTX TLH Laser Temperature :This OID gives the laser temperature of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the laser temperature of the line 1 OTX TLH " ::= { pm1001rrMesrClient 33 } --- ***************************************************** --- LEAF for the clientFreqDeviation article --- ***************************************************** pm1001rrMesrclientFreqDeviation OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (AV-32768)*100) (Unit = MHz) This measure gives the frequency deviation of the line 1 OTX TLH " ::= { pm1001rrMesrClient 34 } --- ***************************************************** --- LEAF for the clientLaserWvlength article --- ***************************************************** pm1001rrMesrclientLaserWvlength OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Optical Module Wavelength :This OID gives the laser wavelength of the Line 1 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=299792458/((193,100+(AV-32768 )*12,5)*10 3)) (Unit = nm) This measure gives the laser wavelength of the line 1 OTX TLH " ::= { pm1001rrMesrClient 35 } --- ***************************************************** --- LEAF for the lineAging article --- ***************************************************** pm1001rrMesrlineAging OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 OTX TLH Aging :This OID gives the aging of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Aging = AV) (Unit = %) This measure gives the aging of the line 2 OTX TLH " ::= { pm1001rrMesrLine 40 } --- ***************************************************** --- LEAF for the lineLaserTemperature article --- ***************************************************** pm1001rrMesrlineLaserTemperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 OTX TLH Laser Temperature :This OID gives the laser temperature of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the laser temperature of the line 2 OTX TLH " ::= { pm1001rrMesrLine 41 } --- ***************************************************** --- LEAF for the lineFreqDeviation article --- ***************************************************** pm1001rrMesrlineFreqDeviation OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 OTX TLH Frequency Deviation :This OID gives the frequency deviation of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Deviation = (AV-32768)*100) (Unit = MHz) This measure gives the frequency deviation of the line 2 OTX TLH " ::= { pm1001rrMesrLine 42 } --- ***************************************************** --- LEAF for the lineLaserWvlength article --- ***************************************************** pm1001rrMesrlineLaserWvlength OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Optical Module Wavelength :This OID gives the laser wavelength of the Line 2 OTX TLH, read from the DDM (Digital Diagnostic Monitoring) (Wavelength=299792458/((193,100+(AV-32768 )*12,5)*10 3)) (Unit = nm) This measure gives the laser wavelength of the line 2 OTX TLH " ::= { pm1001rrMesrLine 43 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group lsd --- ***************************************************** pm1001rrCfgLsd OBJECT IDENTIFIER ::= { pm1001rrConfig 1 } --- ***************************************************** --- LEAF for the table 0012 --- ***************************************************** pm1001rrtableclientLsd OBJECT IDENTIFIER ::= { pm1001rrCfgLsd 1 } pm1001rrCfglsdMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " LSD mode on Client/Line Port :This OID enables/disables the automatic laser shutdown on the Client and Line ports " ::= { pm1001rrtableclientLsd 2 } pm1001rrCfgclientXfpAlarms OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " LSD contributors on Client port :This OID configures the contributors for the automatic laser shutdown of the client port " ::= { pm1001rrtableclientLsd 3 } pm1001rrCfgclientXfpAbsence OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " LSD contributors on Client port :This OID configures the contributors for the automatic laser shutdown of the client port " ::= { pm1001rrtableclientLsd 4 } pm1001rrCfglineXfpAlarms OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " LSD contributors on Line port :This OID configures the contributors for the automatic laser shutdown of the line port " ::= { pm1001rrtableclientLsd 5 } pm1001rrCfglineXfpAbsence OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " LSD contributors on Line port :This OID configures the contributors for the automatic laser shutdown of the line port " ::= { pm1001rrtableclientLsd 6 } --- ***************************************************** --- LEAF for the table Group startUp --- ***************************************************** pm1001rrCfgStartUp OBJECT IDENTIFIER ::= { pm1001rrConfig 2 } --- ***************************************************** --- LEAF for the table 2111 --- ***************************************************** pm1001rrtableclientStartup OBJECT IDENTIFIER ::= { pm1001rrCfgStartUp 1 } pm1001rrCfgclientXfpCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 1 Port :This register configures the default initialisation settings on the client port. " ::= { pm1001rrtableclientStartup 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pm1001rrtablelineStartup OBJECT IDENTIFIER ::= { pm1001rrCfgStartUp 2 } pm1001rrCfglineXfpCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 2 Port :This register configures the default initialisation settings on the line port. " ::= { pm1001rrtablelineStartup 2 } pm1001rrCfgprotocolSelect OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Bitrate selection on Line/Client port :This OID register configure the bitrate for the client and line interface (0=9,953 Gb/s - 1=10,3125 Gb/s - 2=9,953 Gb/s - 3=10,518 Gb/s - 4=10,664 Gb/s - 5=10,709 Gb/s - 6=11,06 Gb/s). " ::= { pm1001rrtablelineStartup 18 } --- ***************************************************** --- LEAF for the table 2511 --- ***************************************************** pm1001rrtableclientOtxtlh OBJECT IDENTIFIER ::= { pm1001rrCfgStartUp 3 } pm1001rrCfgclientDitherControl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Dither Line 1 :This register configures the default initialisation settings on the dither of the client port. " ::= { pm1001rrtableclientOtxtlh 2 } pm1001rrCfgclientDitherRate OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 3 } pm1001rrCfgclientDitherFhz OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 4 } pm1001rrCfgclientPwrLaser OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Defaut Line 1 OTX TLH output Power :This register configures the start-up output power of the line 1 OTX TLH (Unit = dBm) " ::= { pm1001rrtableclientOtxtlh 5 } pm1001rrCfgclientFCurrent OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH Channel :This register configures the start-up laser channel of the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 6 } pm1001rrCfgclientGridCurrent OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH Grid :This register configures the start-up laser grid of the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 7 } pm1001rrCfgclientF0 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 8 } pm1001rrCfgclientPhotodiodeMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH APD mode :This register configures the start-up APD mode of the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 10 } pm1001rrCfgclientPhotodiodeValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 1 OTX TLH APD atten. :This register configures the start-up APD attenuation on the line 1 OTX TLH " ::= { pm1001rrtableclientOtxtlh 11 } --- ***************************************************** --- LEAF for the table 2591 --- ***************************************************** pm1001rrtablelineOtxtlh OBJECT IDENTIFIER ::= { pm1001rrCfgStartUp 4 } pm1001rrCfglineDitherControl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Dither Line 2 :This register configures the default initialisation settings on the dither of the client port. " ::= { pm1001rrtablelineOtxtlh 2 } pm1001rrCfglineDitherRate OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH FM amplitude :This register configures the start-up width of the frequency modulation of the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 3 } pm1001rrCfglineDitherFhz OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH FM frequency :This register configures the start-up frequency of the frequency modulation of the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 4 } pm1001rrCfglinePwrLaser OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Defaut Line 2 OTX TLH output Power :This register configures the start-up output power of the line 2 OTX TLH (Unit = dBm) " ::= { pm1001rrtablelineOtxtlh 5 } pm1001rrCfglineFCurrent OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH Channel :This register configures the start-up laser channel of the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 6 } pm1001rrCfglineGridCurrent OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH Grid :This register configures the start-up laser grid of the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 7 } pm1001rrCfglineF0 OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH lowest Freq :This register configures the start-up lowest frequency supported on the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 8 } pm1001rrCfglinePhotodiodeMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH APD mode :This register configures the start-up APD mode of the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 10 } pm1001rrCfglinePhotodiodeValue OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Line 2 OTX TLH APD atten. :This register configures the start-up APD attenuation on the line 2 OTX TLH " ::= { pm1001rrtablelineOtxtlh 11 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pm1001rrCfgLabels OBJECT IDENTIFIER ::= { pm1001rrConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pm1001rrCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001rrCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001rrCfgLabels 1 } pm1001rrCfgLabelclientEntry OBJECT-TYPE SYNTAX Pm1001rrCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pm1001rrCfgLabelclientIndex } ::= { pm1001rrCfgLabelclientTable 1 } Pm1001rrCfgLabelclientEntry ::= SEQUENCE { pm1001rrCfgLabelclientIndex INTEGER, pm1001rrCfgLabelclientPortn DisplayString } pm1001rrCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pm1001rrCfgLabelclientEntry 1 } pm1001rrCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pm1001rrCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pm1001rrCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001rrCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001rrCfgLabels 2 } pm1001rrCfgLabellineEntry OBJECT-TYPE SYNTAX Pm1001rrCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pm1001rrCfgLabellineIndex } ::= { pm1001rrCfgLabellineTable 1 } Pm1001rrCfgLabellineEntry ::= SEQUENCE { pm1001rrCfgLabellineIndex INTEGER, pm1001rrCfgLabellinePortn DisplayString } pm1001rrCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pm1001rrCfgLabellineEntry 1 } pm1001rrCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pm1001rrCfgLabellineEntry 3 } --- ***************************************************** --- LEAF for the table Group startuptablefive --- ***************************************************** pm1001rrCfgStartuptablefive OBJECT IDENTIFIER ::= { pm1001rrConfig 4 } --- ***************************************************** --- LEAF for the table 0005 --- ***************************************************** pm1001rrCfgOtxtlhcapabilitiesTable OBJECT-TYPE SYNTAX SEQUENCE OF Pm1001rrCfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pm1001rrCfgStartuptablefive 1 } pm1001rrCfgOtxtlhcapabilitiesEntry OBJECT-TYPE SYNTAX Pm1001rrCfgOtxtlhcapabilitiesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the startuptablefive table " INDEX { pm1001rrCfgOtxtlhcapabilitiesIndex } ::= { pm1001rrCfgOtxtlhcapabilitiesTable 1 } Pm1001rrCfgOtxtlhcapabilitiesEntry ::= SEQUENCE { pm1001rrCfgOtxtlhcapabilitiesIndex INTEGER, pm1001rrCfgComponentTypePortn Unsigned32, pm1001rrCfgMiscellaneousPortn Unsigned32, pm1001rrCfgFirstChannelPortn Unsigned32, pm1001rrCfgLastChannelPortn Unsigned32, pm1001rrCfgGridPortn Unsigned32 } pm1001rrCfgOtxtlhcapabilitiesIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the otxtlhcapabilities table " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 1 } pm1001rrCfgComponentTypePortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Component parameters :This OID defines the component parameters " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 3 } pm1001rrCfgMiscellaneousPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Miscellaneous default settings :This OID defines the miscellaneous parameters " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 4 } pm1001rrCfgFirstChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the first channel of the component :This OID defines the first channel number of the PM " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 5 } pm1001rrCfgLastChannelPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Number of the last channel of the component :This OID defines the last channel number of the PM " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 6 } pm1001rrCfgGridPortn OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-only STATUS current DESCRIPTION " Grid value of the component :This OID defines the grid of the PM " ::= { pm1001rrCfgOtxtlhcapabilitiesEntry 7 } pm1001rrCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pm1001rrConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pm1001rrtrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pm1001rrtraps 4 } --- ***************************************************** --- GLOBAL TRAPS --- ***************************************************** pm1001rrLineTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineDdmWarning, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pm1001rrAlmLineDdmWarning "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Warning appears on Line Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Not urgent Line default is activated" ::= { pm1001rrtraps 30 } pm1001rrLineTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineDdmWarning, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Line Not Urgent ON" } --&MATCH { pm1001rrAlmLineDdmWarning "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Line Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Not urgent Line default disappeared" ::= { pm1001rrtraps 31 } pm1001rrLineTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineDdmAlm, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Urgent ON" --&ACTIONS { log, major } --&MATCH { pm1001rrAlmLineDdmAlm "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Line Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Urgent Line default is activated" ::= { pm1001rrtraps 32 } pm1001rrLineTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineDdmAlm, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Line Urgent ON" } --&MATCH { pm1001rrAlmLineDdmAlm "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Line Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Urgent Line default disappeared" ::= { pm1001rrtraps 33 } pm1001rrLineTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineFail, pm1001rrAlmLineHwFail, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Fail ON" --&ACTIONS { log, critical } --&MATCH { pm1001rrAlmLineFail "on", pm1001rrAlmLineHwFail "*", pm1001rrtrapBoardNumber "$3"} --&MESG "Line Port Down on PM1001RR in Slot $3 ($A)" --&FILTNAME "PM1001RR Line HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pm1001rrAlmLineFail "*", pm1001rrAlmLineHwFail "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Line Port Down on PM1001RR in Slot $3 ($A)" DESCRIPTION "Critical Line default is activated" ::= { pm1001rrtraps 34 } pm1001rrLineTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmLineFail, pm1001rrAlmLineHwFail, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Line Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Line Fail ON" } --&MATCH { pm1001rrAlmLineFail "on", pm1001rrAlmLineHwFail "*", pm1001rrtrapBoardNumber "$3"} --&MESG "Line Port Up on PM1001RR in Slot $3 ($A)" --&FILTNAME "PM1001RR Line HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pm1001rrAlmLineFail "*", pm1001rrAlmLineHwFail "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Line Port Up on PM1001RR in Slot $3 ($A)" DESCRIPTION "Critical Line default disappeared" ::= { pm1001rrtraps 35 } --- ***************************************************** --- PORTS TRAPS --- ***************************************************** pm1001rrClientTrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientDdmWarning, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pm1001rrAlmClientDdmWarning "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Warning appears on Client Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Not urgent client default is activated" ::= { pm1001rrtraps 40 } pm1001rrClientTrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientDdmWarning, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Client Not Urgent ON" } --&MATCH { pm1001rrAlmClientDdmWarning "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Warning appears on Client Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Not urgent client default disappeared" ::= { pm1001rrtraps 41 } pm1001rrClientTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientDdmAlm, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Urgent ON" --&ACTIONS { log, major } --&MATCH { pm1001rrAlmClientDdmAlm "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Client Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Urgent client default is activated" ::= { pm1001rrtraps 42 } pm1001rrClientTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientDdmAlm, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Urgent OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Client Urgent ON" } --&MATCH { pm1001rrAlmClientDdmAlm "on", pm1001rrtrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Client Port of PM1001RR in Slot $2 ($A)" DESCRIPTION "Urgent client default disappeared" ::= { pm1001rrtraps 43 } pm1001rrClientTrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientFail, pm1001rrAlmClientHwFail, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Fail ON" --&ACTIONS { log, critical } --&MATCH { pm1001rrAlmClientFail "on", pm1001rrAlmClientHwFail "*", pm1001rrtrapBoardNumber "$3"} --&MESG "Client Port Down on PM1001RR in Slot $3 ($A)" --&FILTNAME "PM1001RR Client HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pm1001rrAlmClientFail "*", pm1001rrAlmClientHwFail "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Client Port Down on PM1001RR in Slot $3 ($A)" DESCRIPTION "Critical client default is activated" ::= { pm1001rrtraps 44 } pm1001rrClientTrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmClientFail, pm1001rrAlmClientHwFail, pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Client Fail OFF" --&ACTIONS { log, normal } --&CLEARS { "PM1001RR Client Fail ON" } --&MATCH { pm1001rrAlmClientFail "on", pm1001rrAlmClientHwFail "*", pm1001rrtrapBoardNumber "$3"} --&MESG "Client Port Up on PM1001RR in Slot $3 ($A)" --&FILTNAME "PM1001RR Client HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pm1001rrAlmClientFail "*", pm1001rrAlmClientHwFail "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Client Port Up on PM1001RR in Slot $3 ($A)" DESCRIPTION "Critical client default disappeared" ::= { pm1001rrtraps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pm1001rrPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pm1001rrAlmDefFuseB, pm1001rrAlmDefFuseA , pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pm1001rrAlmDefFuseB "*", pm1001rrAlmDefFuseA "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Power Input A Fail on PM1001RR in Slot $3 ($A)" --&FILTNAME "PM1001RR Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pm1001rrAlmDefFuseB "on", pm1001rrAlmDefFuseA "*", pm1001rrtrapBoardNumber "$3"} --&MESG "Power Input B Fail on PM1001RR in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pm1001rrtraps 50 } pm1001rrPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pm1001rrAlmDefFuseB, pm1001rrAlmDefFuseA , pm1001rrtrapBoardNumber} STATUS current --&FILTNAME "PM1001RR Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PM1001RR Fuse A Fail ON", "PM1001RR Fuse B Fail ON" } --&MATCH { pm1001rrAlmDefFuseB "on", pm1001rrAlmDefFuseA "on", pm1001rrtrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PM1001RR in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pm1001rrtraps 51 } END