--Acksys enterprise MIB V2.22.0 -- This MIB is compatible with SNMP V2c -- Clean with VIM command: :g/@[GS]ET/d ACKSYS-WLG-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises,mgmt, IpAddress, Counter32, Gauge32, TimeTicks FROM SNMPv2-SMI OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI; --Module Identity acksysMIB MODULE-IDENTITY LAST-UPDATED "201601291500Z" ORGANIZATION "ACKSYS Communication & Systems" CONTACT-INFO "support@acksys.fr" DESCRIPTION "SNMPv2C Module for ACKSYS Solutions" ::= { acksys 2 } -- textual conventions DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- -- SIZE (0..255) PhysAddress ::= OCTET STRING(SIZE (6)) -- This data type is used to model media addresses. For many -- types of media, this will be in a binary representation. -- For example, an ethernet address would be represented as -- a string of 6 octets. acksys OBJECT IDENTIFIER ::= { enterprises 28097 } -- Acksys specific MIBs. network-product OBJECT IDENTIFIER ::= { acksys 1 } c-key-management OBJECT IDENTIFIER ::= { acksys 4 } alarmSettings OBJECT IDENTIFIER ::= { acksys 5 } powerStatus OBJECT IDENTIFIER ::= { acksys 6 } wifiInterface OBJECT IDENTIFIER ::= { network-product 1 } administration OBJECT IDENTIFIER ::= { network-product 2 } os-stat OBJECT IDENTIFIER ::= { network-product 3 } productSpecific OBJECT IDENTIFIER ::= { network-product 4 } lanInterface OBJECT IDENTIFIER ::= {network-product 5} settings OBJECT IDENTIFIER ::= { wifiInterface 1 } bridge-mode OBJECT IDENTIFIER ::= { wifiInterface 2 } access-point-mode OBJECT IDENTIFIER ::= { wifiInterface 3} advancedSettings OBJECT IDENTIFIER ::= { wifiInterface 4 } bridgeAPFiltering OBJECT IDENTIFIER ::= { bridge-mode 8} bridgeRoaming OBJECT IDENTIFIER ::= { bridge-mode 9} bridgeWirelessScan OBJECT IDENTIFIER ::= { bridge-mode 11} bridgeNAT OBJECT IDENTIFIER ::= { bridge-mode 12} bridgeNatPortForwarding OBJECT IDENTIFIER ::= { bridgeNAT 11} bridgeRoamingAdvanced OBJECT IDENTIFIER ::={bridgeRoaming 1} apClientFiltering OBJECT IDENTIFIER ::= { access-point-mode 4} securitySettings OBJECT IDENTIFIER ::= { settings 9 } securityWEP OBJECT IDENTIFIER ::= { securitySettings 2 } securityWPA-WPA2 OBJECT IDENTIFIER ::= { securitySettings 3} securityPresharedKey OBJECT IDENTIFIER ::= { securityWPA-WPA2 1} securityRadius OBJECT IDENTIFIER ::= { securityWPA-WPA2 2} --Obsolete securityBackupRadius OBJECT IDENTIFIER ::= { securityWPA-WPA2 3} --Obsolete securityRadiusAP OBJECT IDENTIFIER ::= { securityRadius 6} securityRadiusBridge OBJECT IDENTIFIER ::= { securityRadius 7} securityRadiusAPBackup OBJECT IDENTIFIER ::= { securityRadiusAP 6} wds OBJECT IDENTIFIER ::= { access-point-mode 5} lanTimeOutSettings OBJECT IDENTIFIER ::= { access-point-mode 8} longDistanceSettings OBJECT IDENTIFIER ::= { advancedSettings 1} wlg-aboard OBJECT IDENTIFIER ::= { productSpecific 1 } alarmSettingsPower1Down OBJECT IDENTIFIER ::= { alarmSettings 2 } alarmSettingsPower2Down OBJECT IDENTIFIER ::= { alarmSettings 3 } alarmSettingsLan1Down OBJECT IDENTIFIER ::= { alarmSettings 4 } alarmSettingsLan2Down OBJECT IDENTIFIER ::= { alarmSettings 5 } alarmSettingsLan3Down OBJECT IDENTIFIER ::= { alarmSettings 6 } alarmSettingsLan4Down OBJECT IDENTIFIER ::= { alarmSettings 7 } alarmSettingsLan5Down OBJECT IDENTIFIER ::= { alarmSettings 8 } alarmSettingsLan6Down OBJECT IDENTIFIER ::= { alarmSettings 9 } alarmSettingsLan7Down OBJECT IDENTIFIER ::= { alarmSettings 10 } alarmSettingsLan8Down OBJECT IDENTIFIER ::= { alarmSettings 11 } alarmSettingsWLANDown OBJECT IDENTIFIER ::= { alarmSettings 12 } --acksys group acksysProductID OBJECT-TYPE SYNTAX INTEGER { wlg-link(1), wlg-aboard-n(2), wlg-link-v2(3), wlg-aboard-n-v2(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Return the product Id code " ::= { acksys 3 } --network-product --Wireless Interface group settingInterfaceSsid OBJECT-TYPE SYNTAX DisplayString (SIZE (0..33)) MAX-ACCESS read-write STATUS current DESCRIPTION "SSID (wireless network name) " ::= { settings 1 } settingInterfaceWifiMode OBJECT-TYPE SYNTAX INTEGER { bridge(1), access-point(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select between MAX-ACCESS POINT and BRIDGE " ::= { settings 2 } settingInterfaceChannel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "A wireless network uses specific channels to handle communication between clients. Some channels in your area may have interference from other electronic devices. Choose the clearest channel to help optimize the performance and coverage of your wireless network.(used in MAX-ACCESS POINT & AD-HOC BRIDGE modes) " ::= { settings 3 } settingInterface80211Mode OBJECT-TYPE SYNTAX INTEGER { b-only(1), g-only(2), mixed-b-g(3), a-only(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select IEEE 802.11x compatibility mode. " ::= { settings 4 } settingInterfaceSuper-a-g-Mode OBJECT-TYPE SYNTAX INTEGER { disable(1), super-g-without-turbo(2), super-g-with-static-turbo(3), super-g-with-dynamic-turbo(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter enables the SUPER A/G mode to reach the 108 Mbits/s speed " ::= { settings 5 } settingEnableRadio OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / Disable wifi radio " ::= { settings 6 } settingTxPoxer OBJECT-TYPE SYNTAX INTEGER { high(1), medium(2), low(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " Set WIFI tx power " ::= { settings 7 } settingRegion OBJECT-TYPE SYNTAX INTEGER { israel(2), usa(4), hong-kong(5), canada(6), australia(7), franceoutdoor(10), europe(14), japan(17), singapore(18), korea(20), mexico(21), indonesia(22), china(23), russia(27), brazil(28), chile(29), thailand(30), peru(31) } MAX-ACCESS read-write STATUS current DESCRIPTION " Set WIFI regulation domain " ::= { settings 8 } settingAntennaChoice OBJECT-TYPE SYNTAX INTEGER { diversity(1), main(2), aux(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " Set the antenna type " ::= { settings 10 } --Setting Transmission rate settingTransmisionRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Set the transmission rate in Mbps Automatic : -1 With SuperAG Mode : 108,96,72,48,36,24,18,12 Without SuperAG mode : 54,48,36,24,18,12,9,6 802.11b mode : 11,5.5,2,1 " ::= { settings 11 } --Setting flag udap sans password settingFlagUdapnopassword OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configure LAN settings without password " ::= { settings 12 } --Setting filter in same net settingFlagFiltersamenet OBJECT-TYPE SYNTAX INTEGER { disable(1), different-subnet-filter(2), custom-subnet-filter(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Subnet filter settings: (1) Disable the filter, (2) Different subnet filter: drop all packets on the different subnet, (3) Custom subnet filter: drop all packets on the custom subnet (You need to define IP and subnet mask of custom subnet.) " ::= { settings 13 } --Setting economy filter settingFlagFilterframecosom OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting economy filter " ::= { settings 14 } --Setting DFS support settingDFSsupport OBJECT-TYPE SYNTAX INTEGER { false(1), true(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting DFS support " ::= { settings 15 } settingFilterCustomIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Set IP address of custom subnet. When settingFlagFiltersamenet is set on '(3) Custom subnet filter', you need to define custom subnet. All packets on the custom subnet will be dropped. " ::= { settings 16 } settingFilterCustomSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Set subnet mask of custom subnet. When settingFlagFiltersamenet is set on '(3) Custom subnet filter', you need to define custom subnet. All packets on the custom subnet will be dropped. " ::= { settings 17 } -- Advanced setting group enable802-11d OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable the 802.11d. " ::= { advancedSettings 2 } enableIsolateSTA OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable the isolating access point. " ::= { advancedSettings 3 } -- long distance settings groups enableLongDistance OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable distance parameter. " ::= { longDistanceSettings 1 } distanceAntennaMeter OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Set the distance between antenna in meter. " ::= { longDistanceSettings 2 } distanceSlotTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { longDistanceSettings 3 } distanceAckTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { longDistanceSettings 4 } distanceCtsTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { longDistanceSettings 5 } --Setting security group securityMode OBJECT-TYPE SYNTAX INTEGER { none(1), wep(2), wpa-wpa2-psk(3), wpa-wpa2(4) } MAX-ACCESS read-write STATUS current DESCRIPTION " Set the security mode " ::= { securitySettings 1 } --WEP group securityModeWepKeyLen OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the WEP key len (64 bits or 128 bits) " ::= { securityWEP 1 } securityModeWepKey-1 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..26)) MAX-ACCESS read-write STATUS current DESCRIPTION "WEP key 1 in hexadecimal format " ::= { securityWEP 2 } securityModeWepKey-2 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..26)) MAX-ACCESS read-write STATUS current DESCRIPTION "WEP key 2 in hexadecimal format " ::= { securityWEP 3 } securityModeWepKey-3 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..26)) MAX-ACCESS read-write STATUS current DESCRIPTION "WEP key 3 in hexadecimal format " ::= { securityWEP 4 } securityModeWepKey-4 OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..26)) MAX-ACCESS read-write STATUS current DESCRIPTION "WEP key 4 in hexadecimal format " ::= { securityWEP 5 } securityModeDefaultWepKey OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the wep key used " ::= { securityWEP 6 } securityModeWepAuthentication OBJECT-TYPE SYNTAX INTEGER { open(1), shared(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set WEP Authentication " ::= { securityWEP 7 } --WPA/WPA2-PSK group securityModeWpaMode OBJECT-TYPE SYNTAX INTEGER { wpa(1), wpa2(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select the wpa mode " ::= { securityWPA-WPA2 4 } securityModeWpaCipherType OBJECT-TYPE SYNTAX INTEGER { tkip(1), aes(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "select the cipher type " ::= { securityWPA-WPA2 5 } securityModeWpaKeyUpdateInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityWPA-WPA2 6 } --Pre-shared key group securityModeWpaPresharedKey OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityPresharedKey 1 } -- radius AP securityModeWPARadiusAPAuthenticationTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAP 1 } securityModeWPARadiusAPIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAP 2 } securityModeWPARadiusAPPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAP 3 } securityModeWPARadiusAPSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAP 4 } securityModeWPARadiusAPMacAddressAuthentication OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAP 5 } --Obsolete OIDs securityModeWPARadiusAuthenticationTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityRadius 1 } securityModeWPARadiusIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityRadius 2 } securityModeWPARadiusPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityRadius 3 } securityModeWPARadiusSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityRadius 4 } securityModeWPARadiusMacAddressAuthentication OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityRadius 5 } --End of Obsolete OIDs -- backup radius securityModeWPABackupRadiusAPIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAPBackup 1 } securityModeWPARadiusBackupAPPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAPBackup 2 } securityModeWPARadiusBackupAPSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAPBackup 3 } securityModeWPABackupRadiusAPMacAddressAuthentication OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusAPBackup 4 } --Obsolete OIDs securityModeWPABackupRadiusIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityBackupRadius 1 } securityModeWPARadiusBackupPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityBackupRadius 2 } securityModeWPARadiusBackupSecret OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityBackupRadius 3 } securityModeWPABackupRadiusMacAddressAuthentication OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "Set the group key interval " ::= { securityBackupRadius 4 } --End of Obsolete OIDs -- radius Bridge securityModeWPARadiusLogin OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusBridge 1 } securityModeWPARadiusPassword OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Set the group key interval " ::= { securityRadiusBridge 2 } --Access point group apClientTable OBJECT-TYPE SYNTAX SEQUENCE OF ApClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Significant only in MAX-ACCESS POINT mode. This table shows information about connected clients." ::= { access-point-mode 1 } apAutomaticChannel OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable the automatic channel select " ::= { access-point-mode 2} apClientCount OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " count the number of entries in ApClientEntry " ::= { access-point-mode 3} apClientEntry OBJECT-TYPE SYNTAX ApClientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows information about the connected client. " INDEX { clientMacAddr } ::= { apClientTable 1 } ApClientEntry ::= SEQUENCE { clientMacAddr PhysAddress, client80211Mode INTEGER, clientTxRate INTEGER , clientRssiPercent Gauge32 } clientMacAddr OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the client connected to the MAX-ACCESS POINT." ::= { apClientEntry 1 } client80211Mode OBJECT-TYPE SYNTAX INTEGER { b-only(1), g-only(2), mixed-b-g(3), a-only(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show client's IEEE 802.11x compatibility mode." ::= { apClientEntry 2 } clientTxRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Client's communication speed in bits per second" ::= { apClientEntry 3 } clientRssiPercent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Client's RSSI (percent)" ::= { apClientEntry 4} settingSSIDVisibility OBJECT-TYPE SYNTAX INTEGER { visible(2), invisible(1) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or Disable SSID Visibility " ::= { access-point-mode 6} enableSTP OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable STP protocol. " ::= { access-point-mode 7 } enableLanTimeout OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable / disable LAN timeout. ACCESS POINT can be configured to auto-disconnect the radio when the LAN is disconnected from the equipment. " ::= { lanTimeOutSettings 1 } lanTimeoutIPSurvey OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Define the IP address where the probe was be sent. " ::= { lanTimeOutSettings 2 } lanTimeoutMaxProbe OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Define the number of probe without response necessairy to disconnect the radio. " ::= { lanTimeOutSettings 3 } lanTimeoutProbeTimeout OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Define the probe response waiting time in seconds. " ::= { lanTimeOutSettings 4 } lanTimeoutProbeInterval OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Define the times in seconds between each probes. " ::= { lanTimeOutSettings 5 } ------------------------ --AP Filtering apClientFilteringEnable OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable / Disable Client Filtering. " ::= { apClientFiltering 1 } apClientFilteringMode OBJECT-TYPE SYNTAX INTEGER { allow(1), deny(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select Client Filtering Mode (allow/Deny) " ::= { apClientFiltering 2 } apClientWirelessFiltering OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable Wireless client filtering " ::= { apClientFiltering 3 } apClientWiredFiltering OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable Wireless client filtering " ::= { apClientFiltering 4 } apClientFilteringMACAddress OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " MAC address field " ::= { apClientFiltering 5 } apClientFilteringName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name Field " ::= { apClientFiltering 6} apClientFilteringSave OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "write 1 to save the rule " ::= { apClientFiltering 7 } apClientFilteringDelete OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, delete the rule which is indexed by the written value " ::= { apClientFiltering 8 } apClientFilteringEnableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, enable the rule which is indexed by the written value " ::= { apClientFiltering 9 } apClientFilteringDisableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, disable the rule which is indexed by the written value " ::= { apClientFiltering 10 } apClientFilteringTable OBJECT-TYPE SYNTAX SEQUENCE OF ApClientFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Significant only in MAX-ACCESS POINT mode. This table shows information AP bridge filtering rules list." ::= { apClientFiltering 11 } apClientFilteringEntry OBJECT-TYPE SYNTAX ApClientFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows information of the rule. " INDEX { apClientFilteringListId } ::= { apClientFilteringTable 1 } ApClientFilteringEntry ::= SEQUENCE { apClientFilteringListId INTEGER, apClientFilteringListName OCTET STRING, apClientFilteringListMAC PhysAddress, apClientFilteringListEnable INTEGER } apClientFilteringListId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Rule index." ::= { apClientFilteringEntry 1 } apClientFilteringListMAC OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the client." ::= { apClientFilteringEntry 3 } apClientFilteringListName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show rule's name" ::= { apClientFilteringEntry 2 } apClientFilteringListEnable OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show if the rule is enabled or not" ::= { apClientFilteringEntry 4 } --End AP Filtering ------------------------ ------------------------ --WDS apWDSEnable OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or Disable WDS. " ::= { wds 1 } apWDSEnableSTP OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or Disable STP when WDS is on " ::= { wds 2 } apWDSMAC1 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " First AP mac address " ::= { wds 3 } apWDSMAC2 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Second AP mac address " ::= { wds 4 } apWDSMAC3 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " Third AP mac address " ::= { wds 5 } apWDSMAC4 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " fourth AP mac address " ::= { wds 6 } apWDSMAC5 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " fith AP mac address " ::= { wds 7 } apWDSMAC6 OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " sixth AP mac address " ::= { wds 8 } --bridge group bridge-modeLinkStatus OBJECT-TYPE SYNTAX INTEGER { up(1), -- ready to pass packets down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "MAX-ACCESS POINT's connection status. " ::= { bridge-mode 1 } bridge-modeMacAP OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION " MAX-ACCESS POINT's MAC ADDRESS we are connected with. " ::= { bridge-mode 2 } bridge-modeRSSI OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " MAX-ACCESS POINT's connection RSSI. " ::= { bridge-mode 3 } bridge-modeRSSIdBm OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Connection's RSSI in dBm. " ::= { bridge-mode 4 } bridge-modeRSSIPercent OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION " Connection's RSSI in percent. " ::= { bridge-mode 5} bridge-modeCurrentTxRate OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " Current communication speed in bits per second. " ::= { bridge-mode 6} bridge-WirelessMode OBJECT-TYPE SYNTAX INTEGER { infrastructure(1), ad-hoc(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Select the Wireless mode. Infrastructure mode require an access point. " ::= { bridge-mode 7} --********************* --******************** -- bridge bridgeAPFilteringEnable OBJECT-TYPE SYNTAX INTEGER { off(1), on(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or Disable AP Filtering. " ::= { bridgeAPFiltering 1 } bridgeAPFilteringMode OBJECT-TYPE SYNTAX INTEGER { allow(1), deny(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Select AP Filtering Mode (allow/Deny) " ::= { bridgeAPFiltering 2 } bridgeAPFilteringMACAddress OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-write STATUS current DESCRIPTION " MAC address field " ::= { bridgeAPFiltering 3 } bridgeAPFilteringName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name Field " ::= { bridgeAPFiltering 4 } bridgeAPFilteringSave OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "write 1 to save the rule " ::= { bridgeAPFiltering 5 } bridgeAPFilteringDelete OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, delete the rule which is indexed by the written value " ::= { bridgeAPFiltering 6 } bridgeAPFilteringEnableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, enable the rule which is indexed by the written value " ::= { bridgeAPFiltering 7 } bridgeAPFilteringDisableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, disable the rule which is indexed by the written value " ::= { bridgeAPFiltering 8 } bridgeAPFilteringTable OBJECT-TYPE SYNTAX SEQUENCE OF BridgeAPFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Significant only in MAX-ACCESS POINT mode. This table shows information bridge AP filtering rules list." ::= { bridgeAPFiltering 9 } bridgeAPFilteringEntry OBJECT-TYPE SYNTAX BridgeAPFilteringEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows information of the rule. " INDEX { bridgeAPFilteringListId } ::= { bridgeAPFilteringTable 1 } BridgeAPFilteringEntry ::= SEQUENCE { bridgeAPFilteringListId INTEGER, bridgeAPFilteringListName OCTET STRING, bridgeAPFilteringListMAC PhysAddress, bridgeAPFilteringListEnable INTEGER } bridgeAPFilteringListId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Rule index." ::= { bridgeAPFilteringEntry 1 } bridgeAPFilteringListMAC OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the client." ::= { bridgeAPFilteringEntry 3 } bridgeAPFilteringListName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show rule's name" ::= { bridgeAPFilteringEntry 2 } bridgeAPFilteringListEnable OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show if a rule is enabled or not. " ::= { bridgeAPFilteringEntry 4 } bridgeChannelList OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..40)) MAX-ACCESS read-write STATUS current DESCRIPTION "A wireless network uses specific channels in the 2.4GHz or 5GHz wireless spectrum to handle communication between clients. Some channels in your area may have interference from other electronic devices. Your wireless bridge will use the channel that is used by the access point it will associate with. But you can select here your channel preference to help optimize the performance and coverage of your wireless network. If you used the roaming, Acksys recommend to used only one channel for better bandwith. " ::= { bridge-mode 10 } --roaming setting bridgeRoamingEnable OBJECT-TYPE SYNTAX INTEGER{ disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Roaming enables WiFi clients to roam among AP when WiFi RSSI of the current AP becomes weak. This radio button enables/disables the roaming capabilities of the bridge. " ::={bridgeRoaming 2} bridgeRoamingRSSIThreshold-dBm OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Allows to configure the RSSI roaming threshold (in dBm, or percent) from which the roaming algorithm (to find a better AP) will start. AP changing will only be effective if the current RSSI is lower than that threshold, and if a new AP with a better RSSI has been detected. " ::= {bridgeRoaming 3} bridgeRoamingRSSIThreshold-percent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Allows to configure the RSSI roaming threshold (in dBm, or percent) from which the roaming algorithm (to find a better AP) will start. AP changing will only be effective if the current RSSI is lower than that threshold, and if a new AP with a better RSSI has been detected. " ::= {bridgeRoaming 4} bridgeRoamingAdvancedScanThreshold-dbm OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Allows to configure the RSSI scan threshold (in dBm, or in percent) from which the access point active scan will start. The access point active scan process looking on each valid channel the access point where it will be possible to roam. " ::= {bridgeRoamingAdvanced 1} bridgeRoamingAdvancedScanThreshold-percent OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Allows to configure the RSSI scan threshold (in dBm, or in percent) from which the access point active scan will start. The access point active scan process looking on each valid channel the access point where it will be possible to roam. " ::= {bridgeRoamingAdvanced 2} bridgeRoamingAdvancedScanPeriod OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Allow to configure the time between two scan. Reduce this time increase the Access Point discover, but decrease the bandwith if you used more one channel. " ::= {bridgeRoamingAdvanced 3} bridgeRoamingAdvancedScanDuration OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Allow to configure the duration while the bridge waiting the Access Point answer. Reduce this duration increase the Bandwith when you used more one channel, but decrase the Access Point discover. " ::= {bridgeRoamingAdvanced 4} bridgeRoamingAdvancedAPLossDetection OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "If nothing is received from the AP during a certain amount of time, it will be considered unreachable. This amount of time is computed as: 'AP timeout' = 'AP loss detection' x 'beacon interval'. The recommended value for 'AP loss detection' is 5. The recommended value for 'Beacon interval' (which should be configured in your AP) is 50 ms. If the AP timeout is set too low, it may decrease the bandwidth and roaming performance. " ::= {bridgeRoamingAdvanced 5} -- End bridge filter --*********************** --Bridge status scan bridgeWileressScanTable OBJECT-TYPE SYNTAX SEQUENCE OF BridgeWirelessScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Significant only in MAX-ACCESS POINT mode. This table shows information AP bridge filtering rules list." ::= { bridgeWirelessScan 1 } bridgeWirelessScanEntry OBJECT-TYPE SYNTAX BridgeWirelessScanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Shows information of the rule. " INDEX { apClientFilteringListId } ::= { bridgeWileressScanTable 1 } BridgeWirelessScanEntry ::= SEQUENCE { bridgeWirelessScanAPMac PhysAddress, bridgeWirelessScanSSID DisplayString, bridgeWirelessScanChannel INTEGER, bridgeWirelessScanMode INTEGER, bridgeWirelessScanSecurity INTEGER, bridgeWirelessScanRssi INTEGER } bridgeWirelessScanAPMac OBJECT-TYPE SYNTAX PhysAddress MAX-ACCESS read-only STATUS current DESCRIPTION "MAC address of the access point." ::= { bridgeWirelessScanEntry 1 } bridgeWirelessScanSSID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..33)) MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { bridgeWirelessScanEntry 2 } bridgeWirelessScanChannel OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { bridgeWirelessScanEntry 3 } bridgeWirelessScanMode OBJECT-TYPE SYNTAX INTEGER { b-only(1), g-only(2), mixed-b-g(3), a-only(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Show AP's IEEE 802.11x compatibility mode." ::= { bridgeWirelessScanEntry 4 } bridgeWirelessScanSecurity OBJECT-TYPE SYNTAX INTEGER { none(0), wep(1), wpa(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { bridgeWirelessScanEntry 5 } bridgeWirelessScanRssi OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { bridgeWirelessScanEntry 6 } --end bridge status scan --BrigeNAT brigeNATStatus OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable / disable NAT " ::= { bridgeNAT 1 } brigeNATEnablePing OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable / disable ping response from WAN " ::= { bridgeNAT 2 } brigeNATEnableProductWebServer OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable / disable the internal web server from WAN " ::= { bridgeNAT 3 } brigeNATInternalWebServerPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port used by internal web server from WAN " ::= { bridgeNAT 4 } brigeNATEnableProductSnmpServer OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable / disable the internal snmp server from WAN " ::= { bridgeNAT 5 } brigeNATInternalWebSnmpPort OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "TCP port used by internal snmp server from WAN " ::= { bridgeNAT 6 } brigeNATWanIpAddrMode OBJECT-TYPE SYNTAX INTEGER {static(1),dhcp(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Ip address mode on wan side " ::= { bridgeNAT 7 } brigeNATWanIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Static Ip address on wan side " ::= { bridgeNAT 8 } brigeNATWanSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Subnet mask on wan side " ::= { bridgeNAT 9 } brigeNATWanGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Gateway ip address on wan side " ::= { bridgeNAT 10 } bridgeNatPortForwardingName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Show rule's name " ::= { bridgeNatPortForwarding 2 } bridgeNatPortForwardingIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Show ipaddress to forward data " ::= { bridgeNatPortForwarding 3 } bridgeNatPortForwardingPublicTcpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Show public TCP port " ::= { bridgeNatPortForwarding 4 } bridgeNatPortForwardingPrivateTcpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Show private TCP port " ::= { bridgeNatPortForwarding 5 } bridgeNatPortForwardingPublicUdpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Show public TCP port " ::= { bridgeNatPortForwarding 6 } bridgeNatPortForwardingPrivateUdpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Show private TCP port " ::= { bridgeNatPortForwarding 7 } bridgeNatPortForwardingEnableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, enable the rule which is indexed by the written value " ::= { bridgeNatPortForwarding 8 } bridgeNatPortForwardingDisableRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, disable the rule which is indexed by the written value " ::= { bridgeNatPortForwarding 9 } bridgeNatPortForwardingSaveRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, save the rule which is indexed by the written value " ::= { bridgeNatPortForwarding 10 } bridgeNatPortForwardingDeleteRule OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "when writed, delete the rule which is indexed by the written value " ::= { bridgeNatPortForwarding 11 } bridgeNatPortForwardingTable OBJECT-TYPE SYNTAX SEQUENCE OF BridgeNatPortForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " This table show information on port forwading rules " ::= { bridgeNatPortForwarding 1 } bridgeNatPortForwardingEntry OBJECT-TYPE SYNTAX BridgeNatPortForwardingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "shows information of rule. " INDEX {bridgeNatPortForwardingListId} ::= {bridgeNatPortForwardingTable 1} BridgeNatPortForwardingEntry ::= SEQUENCE { bridgeNatPortForwardingListId INTEGER, bridgeNatPortForwardingListEnable INTEGER, bridgeNatPortForwardingListName OCTET STRING, bridgeNatPortForwardingListIpAddr IpAddress, bridgeNatPortForwardingListPublicTcpPort OCTET STRING, bridgeNatPortForwardingListPrivateTcpPort OCTET STRING, bridgeNatPortForwardingListPublicUdpPort OCTET STRING, bridgeNatPortForwardingListPrivateUdpPort OCTET STRING } bridgeNatPortForwardingListId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Rule index" ::= { bridgeNatPortForwardingEntry 1 } bridgeNatPortForwardingListName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show rule's name" ::= { bridgeNatPortForwardingEntry 2 } bridgeNatPortForwardingListIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Show ipaddress to forward data" ::= { bridgeNatPortForwardingEntry 3 } bridgeNatPortForwardingListPublicTcpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show public TCP port" ::= { bridgeNatPortForwardingEntry 4 } bridgeNatPortForwardingListPrivateTcpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show private TCP port" ::= { bridgeNatPortForwardingEntry 5 } bridgeNatPortForwardingListPublicUdpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show public TCP port" ::= { bridgeNatPortForwardingEntry 6 } bridgeNatPortForwardingListPrivateUdpPort OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Show private TCP port" ::= { bridgeNatPortForwardingEntry 7 } bridgeNatPortForwardingListEnable OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Rule state" ::= { bridgeNatPortForwardingEntry 8 } --end bridgeNAT --********************* -- Administration group adminReset OBJECT-TYPE SYNTAX INTEGER {reset(1)} MAX-ACCESS read-write STATUS current DESCRIPTION " Writing 1 resets the product. This must be done after each configuration change. " ::= { administration 1} adminResetFactory OBJECT-TYPE SYNTAX INTEGER {resetfactory(1)} MAX-ACCESS read-write STATUS current DESCRIPTION " Writing 1 resets the product to the factory settings. " ::= { administration 2} adminEnableWebServer OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or Disable internal webserver. " ::= { administration 3} adminAutoSave OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or Disable the automatic change saving. When this function is disable, the modification is not save automaticaly after change and certainly OID is applied imediatly. " ::= { administration 4} adminSave OBJECT-TYPE SYNTAX INTEGER { saveNotRequire(3), saveRequire(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Write 1 to save the modification in flash. Read this OID to know if a save is require. " ::= { administration 5} -- os-stat group os-statFreeHeap OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of memory currently available, measured in bytes. " ::= { os-stat 1 } os-statTotalHeap OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The total size of the heap, measured in bytes. " ::= { os-stat 2 } os-statHeapLowWater OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Low water mark for the heap. Writing any value this variable will always reset the low water to the total heap size. " ::= { os-stat 3 } os-statNetpageFree OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of netpages currently available, measured in bytes. " ::= { os-stat 4 } os-statNetpageLowWater OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Low water mark for the netpage. " ::= { os-stat 5 } -- wlg-aboard group wlg-aboard-PW1-state OBJECT-TYPE SYNTAX INTEGER {powerOff(1), powerOn(2)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Power 1 state " ::= { wlg-aboard 1 } wlg-aboard-PW2-state OBJECT-TYPE SYNTAX INTEGER {powerOff(1), powerOn(2)} MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Power 2 state " ::= { wlg-aboard 2 } -- lanInterface group lanInterfaceIpAddrMode OBJECT-TYPE SYNTAX INTEGER {static(1),dhcp(2)} MAX-ACCESS read-write STATUS current DESCRIPTION "Static or DHCP Ip settings " ::= { lanInterface 1 } lanInterfaceIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Product IP address " ::= { lanInterface 2 } lanInterfaceSubNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Network mask " ::= { lanInterface 3 } lanInterfaceGatewayIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP gateway " ::= { lanInterface 4 } lanInterfaceHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "Adresse IP de la gateway " ::= { lanInterface 5 } lanInterfaceLocalDomainName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..33)) MAX-ACCESS read-write STATUS current DESCRIPTION "Adresse IP de la gateway " ::= { lanInterface 6 } -- c-key-management ckeyManagementCopySettingTo OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Write 1 to copy the current settings to the C-KEY. After this action, all previous data in the C-KEY are lost. " ::= { c-key-management 1 } ckeyManagementCopySettingFrom OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION " Write 1 to copy the product settings from the C-KEY. After this action, the product has C-KEY settings. Reboot your device to apply the new settings. " ::= { c-key-management 2 } -- alarmSettings alarmSettingsTest OBJECT-TYPE SYNTAX INTEGER {set(1),clear(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " Allow to get and set the Alarm output status. " ::= { alarmSettings 1 } alarmSettingsPower1DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsPower1Down 1 } alarmSettingsPower1DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsPower1Down 2 } alarmSettingsPower1DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsPower1Down 3 } alarmSettingsPower2DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsPower2Down 1 } alarmSettingsPower2DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsPower2Down 2 } alarmSettingsPower2DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsPower2Down 3 } alarmSettingsLan1DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan1Down 1 } alarmSettingsLan1DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan1Down 2 } alarmSettingsLan1DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan1Down 3 } alarmSettingsLan2DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan2Down 1 } alarmSettingsLan2DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan2Down 2 } alarmSettingsLan2DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan2Down 3 } alarmSettingsLan3DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan3Down 1 } alarmSettingsLan3DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan3Down 2 } alarmSettingsLan3DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan3Down 3 } alarmSettingsLan4DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan4Down 1 } alarmSettingsLan4DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan4Down 2 } alarmSettingsLan4DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan4Down 3 } alarmSettingsLan5DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan5Down 1 } alarmSettingsLan5DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan5Down 2 } alarmSettingsLan5DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan5Down 3 } alarmSettingsLan6DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan6Down 1 } alarmSettingsLan6DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan6Down 2 } alarmSettingsLan6DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan6Down 3 } alarmSettingsLan7DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan7Down 1 } alarmSettingsLan7DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan7Down 2 } alarmSettingsLan7DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan7Down 3} alarmSettingsLan8DownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan8Down 1 } alarmSettingsLan8DownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsLan8Down 2 } alarmSettingsLan8DownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsLan8Down 3 } alarmSettingsWLANDownEnable OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsWLANDown 1 } alarmSettingsWLANDownEnableAutomaticReset OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2)} MAX-ACCESS read-write STATUS current DESCRIPTION " " ::= { alarmSettingsWLANDown 2 } alarmSettingsWLANDownStatus OBJECT-TYPE SYNTAX INTEGER {disable(1),enable(2),ack(3)} MAX-ACCESS read-write STATUS current DESCRIPTION " Read to know the alarm source status (disable / enable ) Write 3 to acknowledge the alarm source. " ::= { alarmSettingsWLANDown 3 } -- powerStatus powerStatus-PW1-state OBJECT-TYPE SYNTAX INTEGER {powerOff(1), powerOn(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Power 1 state " ::= { powerStatus 1 } powerStatus-PW2-state OBJECT-TYPE SYNTAX INTEGER {powerOff(1), powerOn(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "Power 2 state " ::= { powerStatus 2 } --*********************** -- Serial interface -- ------------------------ -- +++ Serial format +++ END