-- -- zhoneSechtor100.mib -- MIB generated by MG-SOFT Visual MIB Builder Version 2.1 Build 205 -- Tuesday, October 16, 2001 at 09:18:01 -- ZHONE-SECHTOR100-MIB DEFINITIONS ::= BEGIN IMPORTS Integer32, OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI MacAddress, TruthValue FROM SNMPv2-TC sechtor100, zhoneModules, zhoneShelfIndex, zhoneSlotIndex FROM Zhone ZhoneRowStatus FROM Zhone-TC; -- -- -- -- zhoneSechtor100 MODULE-IDENTITY LAST-UPDATED "200109281029Z" ORGANIZATION "Zhone Technologies, Inc" CONTACT-INFO " Postal: Zhone Technologies, Inc. @ Zhone Way 7001 Oakport Street Oakland, CA 94621 USA Toll-Free: +1 877-ZHONE20 (+1 877-946-6320) Tel: +1-510-777-7000 Fax: +1-510-777-7001 E-mail: support@zhone.com" DESCRIPTION "MIB module for elements specific to Sechtor 100 products." REVISION "200109281029Z" DESCRIPTION "V01.01.00 Introduce sechtor100ConfigTable" REVISION "200012271117Z" DESCRIPTION "V01.00.01 - Add Zhone keywording" REVISION "200012211700Z" DESCRIPTION "V01.00.00 - Initial Release" ::= { zhoneModules 19 } -- -- Node definitions -- -- Currently, there are environmental variables for monitoring -- fans and thermometers. -- -- There are two thermometers on the Sechtor 100 board. In this -- MIB, thermometers 'A' and 'B' are used to differentiate -- these two thermometers: -- -- Thermometer A - the thermometer located near the 750 -- processor. It is expected that this thermometer have a higher -- temperature reading than thermometer B because of the heat -- generated by the processor. It is recommended that a higher -- upper threshold is set for this thermometer. -- -- Thermometer B - the thermometer located near the outlet on -- the right side of the Sechtor 100 board. sechtor100Environment OBJECT-IDENTITY STATUS deprecated DESCRIPTION "All the scalar objects under sechor100Environment are deprecated and replaced by their respective objects indexed by zhoneShelfIndex and zhoneSlotIndex. " ::= { sechtor100 1 } -- s100FanOperationalStatus OBJECT-TYPE SYNTAX INTEGER { operational(1), fanFailure(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'. " ::= { sechtor100Environment 1 } -- s100ThermoAUpperThreshold OBJECT-TYPE SYNTAX Integer32 (45..80) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius." ::= { sechtor100Environment 2 } -- s100ThermoBUpperThreshold OBJECT-TYPE SYNTAX Integer32 (45..80) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius." ::= { sechtor100Environment 3 } -- s10ThermoALowerThreshold OBJECT-TYPE SYNTAX Integer32 (-10..5) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius." ::= { sechtor100Environment 4 } -- s100ThermoBLowerThreshold OBJECT-TYPE SYNTAX Integer32 (-10..5) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius." ::= { sechtor100Environment 5 } -- s100ThermoATemperature OBJECT-TYPE SYNTAX Integer32 (-55..125) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius." ::= { sechtor100Environment 6 } -- s100ThermoBTemperature OBJECT-TYPE SYNTAX Integer32 (-55..125) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius." ::= { sechtor100Environment 7 } -- s100ThermoAOperationalStatus OBJECT-TYPE SYNTAX INTEGER { withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold." ::= { sechtor100Environment 8 } -- s100ThermoBOperationalStatus OBJECT-TYPE SYNTAX INTEGER { withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold." ::= { sechtor100Environment 9 } sechtor100Traps OBJECT-IDENTITY STATUS current DESCRIPTION "All Sechtor 100 MIB traps are defined under sechtor100Traps." ::= { sechtor100 2 } sechtor100TrapsPrefix OBJECT-IDENTITY STATUS current DESCRIPTION "Prefix 0 for Sechtor 100 MIB traps as required by SNMPv2." ::= { sechtor100Traps 0 } s100FanStatusChange NOTIFICATION-TYPE OBJECTS { s100FanOperationalStatus } STATUS deprecated DESCRIPTION "This trap is generated whenever the value of s100FanOperationalStatus changes. This trap is deprecated and is replaced by sechtor100FanStatusChange." ::= { sechtor100TrapsPrefix 1 } s100ThermoStatusChange NOTIFICATION-TYPE OBJECTS { s100ThermoATemperature, s100ThermoBTemperature, s100ThermoAOperationalStatus, s100ThermoBOperationalStatus } STATUS deprecated DESCRIPTION "This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. This trap is deprecated and is replaced by sechtor100ThermoStatusChange." ::= { sechtor100TrapsPrefix 2 } sechtor100FanStatusChange NOTIFICATION-TYPE OBJECTS { sechtor100FanOperationalStatus } STATUS current DESCRIPTION "This trap is generated whenever the value of sechtor100FanOperationalStatus changes. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects." ::= { sechtor100TrapsPrefix 3 } sechtor100ThermoStatusChange NOTIFICATION-TYPE OBJECTS { sechtor100ThermoATemperature, sechtor100ThermoBTemperature, sechtor100ThermoAOperationalStatus, sechtor100ThermoBOperationalStatus } STATUS current DESCRIPTION "This trap is generated whenever sechtor100ThermoAOperationalStatus or sechtor100ThermoBOperationalStatus changes its value. The Sechtor 100 is identified by the shelf and slot number from instance OID's contained in the trap VarBind objects." ::= { sechtor100TrapsPrefix 4 } sechtor100ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Sechtor100ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains redundancy variables and environmental variables for monitoring fans and thermometers. For redundancy, the peer MAC address is maintained in this table. Also, one variable specifies whether redundancy is enabled or not. There are two thermometers on the Sechtor 100 board. In this MIB, thermometers 'A' and 'B' are used to differentiate these two thermometers: Thermometer A - the thermometer located near the 750 processor. It is expected that this thermometer have a higher temperature reading than thermometer B because of the heat generated by the processor. It is recommended that a higher upper threshold is set for this thermometer. Thermometer B - the thermometer located near the outlet on the right side of the Sechtor 100 board. The profile for this table will be auto-created as 1/1 with the sechtor100RedundancyEnable variable set to FALSE. This profile should not be deleted except for the following two cases: 1) When a unit operating in simplex mode is intended to be used in duplex mode as the slot 2 of the redundant system. The user needs to create a 1/2 profile. 2) The unit configured as slot 2 of a redundant system is intended to be used in simplex mode. Then the 1/2 profile should be deleted and replaced with a 1/1 profile." ::= { sechtor100 3 } sechtor100ConfigEntry OBJECT-TYPE SYNTAX Sechtor100ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the sechtor100ConfigTable." INDEX { zhoneShelfIndex, zhoneSlotIndex } ::= { sechtor100ConfigTable 1 } Sechtor100ConfigEntry ::= SEQUENCE { sechtor100PeerMacAddress MacAddress, sechtor100RedundancyEnable TruthValue, sechtor100FanOperationalStatus INTEGER, sechtor100ThermoAUpperThreshold Integer32, sechtor100ThermoBUpperThreshold Integer32, sechtor100ThermoALowerThreshold Integer32, sechtor100ThermoBLowerThreshold Integer32, sechtor100ThermoATemperature Integer32, sechtor100ThermoBTemperature Integer32, sechtor100ThermoAOperationalStatus INTEGER, sechtor100ThermoBOperationalStatus INTEGER, sechtor100RowStatus ZhoneRowStatus } sechtor100PeerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Mac address of the peer s100 unit." ::= { sechtor100ConfigEntry 1 } sechtor100RedundancyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Whether or not the redundancy functionality has been enabled. If this value is false, redundancy is not enable. " ::= { sechtor100ConfigEntry 2 } -- sechtor100FanOperationalStatus OBJECT-TYPE SYNTAX INTEGER { operational(1), fanFailure(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes the working status of the four fans for the Sechtor 100. If any one of the four fans is not running correctly, this variable shows 'fanFailure'. When all the fans are working, the value of this variable is 'operational'." ::= { sechtor100ConfigEntry 3 } -- sechtor100ThermoAUpperThreshold OBJECT-TYPE SYNTAX Integer32 (45..80) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the upper threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is above this value, s100ThermoAOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 65 degrees Celsius." DEFVAL { 65 } ::= { sechtor100ConfigEntry 4 } sechtor100ThermoBUpperThreshold OBJECT-TYPE SYNTAX Integer32 (45..80) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the upper threshold for thermometer B in degrees Celsius. When s100ThermoBTemperature is above this value, s100ThermoBOperationalStatus would be 'overUpperThreshold' and a trap will be generated. Valid range is 45..80 degrees Celsius and the default is 60 degrees Celsius." DEFVAL { 60 } ::= { sechtor100ConfigEntry 5 } sechtor100ThermoALowerThreshold OBJECT-TYPE SYNTAX Integer32 (-10..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the lower threshold for thermometer A in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoAOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius." DEFVAL { -5 } ::= { sechtor100ConfigEntry 6 } -- sechtor100ThermoBLowerThreshold OBJECT-TYPE SYNTAX Integer32 (-10..5) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable specifies the lower threshold for thermometer B in degrees Celsius. When s100ThermoATemperature is below this value, s100ThermoBOperationalStatus would be 'belowLowerThreshold' and a trap will be generated. Valid range is -10..5 degrees Celsius and the default is -5 degrees Celsius." DEFVAL { -5 } ::= { sechtor100ConfigEntry 7 } -- sechtor100ThermoATemperature OBJECT-TYPE SYNTAX Integer32 (-55..125) MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature in degrees Celsius read by the IC thermometer sensor A on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer A is located. The valid temperature range for the thermometer is -55..125 degrees Celsius." ::= { sechtor100ConfigEntry 8 } -- sechtor100ThermoBTemperature OBJECT-TYPE SYNTAX Integer32 (-55..125) MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature in degrees Celsius read by the IC thermometer sensor B on the PCB board. It is effectively the internal ambient temperature inside the enclosure where thermometer B is located. The valid temperature range for the thermometer is -55..125 degrees Celsius." ::= { sechtor100ConfigEntry 9 } sechtor100ThermoAOperationalStatus OBJECT-TYPE SYNTAX INTEGER { withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status indicator for thermometer A. Valid values are: * withinOperationalRange - s100ThermoATemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoATemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoATemperature is lower than its lower threshold." ::= { sechtor100ConfigEntry 10 } -- sechtor100ThermoBOperationalStatus OBJECT-TYPE SYNTAX INTEGER { withinOperationalRange(1), overUpperThreshold(2), belowLowerThreshold(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status indicator for thermometer B. Valid values are: * withinOperationalRange - s100ThermoBTemperature is within its lower and upper threshold range. * overUpperThreshold - s100ThermoBTemperature is higher than its upper threshold. * belowLowerThreshold - s100ThermoBTemperature is lower than its lower threshold." ::= { sechtor100ConfigEntry 11 } sechtor100RowStatus OBJECT-TYPE SYNTAX ZhoneRowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to control row creation and deletion. A row in this table is created using a single SNMP SET request with varbinds for: a) sechtor100RowStatus set to'CreateAndGo', b) the following READ-CREATE object(s): * If 'createAndGo' successfully created a new row, the RowStatus will be 'active'. Subsequent to successful row creation, the RowStatus can be retrieved via an SNMP GET and the returned RowStatus value is active. If the 'createAndGo' was unsuccessful an SNMP error will be returned and a subsequent GET on the non-existent row will also return an SNMP error of noSuchInstance. An SNMP SET with the RowStatus value of 'destroy' indicates that the agent should remove the row from service and then delete it." ::= { sechtor100ConfigEntry 12 } END -- -- zhoneSechtor100.mib --