WebGraph-AnalogIn-57644-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 22.06.2010 Webio -- Syntax correction ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 02.12.2008 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 25.11.2005 #57644, WebGraph AnalogIn 2x 0..10V -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57644, WebGraph AnalogIn -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57644, WebGraph AnalogIn -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 17.05.2005 #57644, WebGraph AnalogIn -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57606, WebGraph Thermo-Hygrometer -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 08.09.2004 #57606 WebGraph Thermo-Hygrometer -- New: -- wtWebGraphThermHygroAlarmRHMin -- wtWebGraphThermHygroAlarmRHMax -- wtWebGraphThermHygroAlarmRHHysteresis -- wtWebGraphThermHygroPortSensorSelect -- wtWebGraphThermHygroAlarmDeltaTemp -- wtWebGraphThermHygroAlarmAHMin -- wtWebGraphThermHygroAlarmAHMax ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebGraph Tree wtWebGraphAnalogIn57644 OBJECT IDENTIFIER ::= { wtWebio 12 } -- wtWebGraphAnalogIn57644 Tree wtWebGraphAnalogIn57644Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644 1 } wtWebGraphAnalogIn57644SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644 2 } wtWebGraphAnalogIn57644Config OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644 3 } wtWebGraphAnalogIn57644Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644 4 } -- wtWebGraphAnalogIn57644Config Tree wtWebGraphAnalogIn57644Device OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Config 1 } wtWebGraphAnalogIn57644Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Config 2 } wtWebGraphAnalogIn57644Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Config 3 } -- wtWebGraphAnalogIn57644Device Tree wtWebGraphAnalogIn57644Text OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 1 } wtWebGraphAnalogIn57644TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 2 } wtWebGraphAnalogIn57644Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 3 } wtWebGraphAnalogIn57644Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 4 } wtWebGraphAnalogIn57644Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 5 } wtWebGraphAnalogIn57644Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Device 6 } -- wtWebGraphAnalogIn57644TimeDate Tree wtWebGraphAnalogIn57644TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644TimeDate 1 } wtWebGraphAnalogIn57644TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644TimeDate 2 } wtWebGraphAnalogIn57644DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644TimeDate 3 } -- wtWebGraphAnalogIn57644Basic Tree wtWebGraphAnalogIn57644Network OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 1 } wtWebGraphAnalogIn57644HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 2 } wtWebGraphAnalogIn57644Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 3 } wtWebGraphAnalogIn57644SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 4 } wtWebGraphAnalogIn57644UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 5 } wtWebGraphAnalogIn57644Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 6 } wtWebGraphAnalogIn57644FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Basic 7 } -- wtWebGraphAnalogIn57644Graphics Tree wtWebGraphAnalogIn57644GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Graphics 1 } wtWebGraphAnalogIn57644GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Graphics 2 } wtWebGraphAnalogIn57644GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57644Graphics 3 } -- wtWebGraphAnalogIn57644Inventory Group ------------------------ wtWebGraphAnalogIn57644Sensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensors" ::= { wtWebGraphAnalogIn57644Inventory 1 } -- Interface Table wtWebGraphAnalogIn57644SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebGraphAnalogIn57644Inventory 2 } wtWebGraphAnalogIn57644SensorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor numbers." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644SensorTable 1 } WtWebGraphAnalogIn57644SensorEntry ::= SEQUENCE { wtWebGraphAnalogIn57644SensorNo INTEGER } wtWebGraphAnalogIn57644SensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor number." ::= { wtWebGraphAnalogIn57644SensorEntry 1 } -- wtWebGraphAnalogIn57644Values Table wtWebGraphAnalogIn57644ValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalogIn57644Inventory 3 } wtWebGraphAnalogIn57644ValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644ValuesTable 1 } WtWebGraphAnalogIn57644ValuesEntry ::= SEQUENCE{ wtWebGraphAnalogIn57644Values OCTET STRING } wtWebGraphAnalogIn57644Values OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII, 7 characters in length." ::= { wtWebGraphAnalogIn57644ValuesEntry 1 } -- wtWebGraphAnalogIn57644BinaryValues Table wtWebGraphAnalogIn57644BinaryValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalogIn57644Inventory 4 } wtWebGraphAnalogIn57644BinaryValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary measurement values of the sensors." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644BinaryValuesTable 1 } WtWebGraphAnalogIn57644BinaryValuesEntry ::= SEQUENCE{ wtWebGraphAnalogIn57644BinaryValues INTEGER } wtWebGraphAnalogIn57644BinaryValues OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value." ::= { wtWebGraphAnalogIn57644BinaryValuesEntry 1 } -- wtWebGraphAnalogIn57644SessCntrl Group -------------------------------- wtWebGraphAnalogIn57644SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalogIn57644SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebGraphAnalogIn57644SessCntrl 1 } wtWebGraphAnalogIn57644SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644SessCntrl-NoSession(0), wtWebGraphAnalogIn57644SessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebGraphAnalogIn57644SessCntrl 2 } wtWebGraphAnalogIn57644SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebGraphAnalogIn57644SessCntrl 3 } wtWebGraphAnalogIn57644SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebGraphAnalogIn57644SessCntrl 4 } wtWebGraphAnalogIn57644SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebGraphAnalogIn57644SessCntrl 5 } -- wtWebGraphAnalogIn57644Text Group ------------------------ wtWebGraphAnalogIn57644DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57644Text 1 } wtWebGraphAnalogIn57644DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57644Text 2 } wtWebGraphAnalogIn57644DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57644Text 3 } wtWebGraphAnalogIn57644DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57644Text 4 } -- wtWebGraphAnalogIn57644TimeZone Group ---------------------------- wtWebGraphAnalogIn57644TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 1 } wtWebGraphAnalogIn57644TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 2 } wtWebGraphAnalogIn57644TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebGraphAnalogIn57644TimeZone 3 } wtWebGraphAnalogIn57644StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 4 } wtWebGraphAnalogIn57644StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 5 } wtWebGraphAnalogIn57644StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebGraphAnalogIn57644TimeZone 6 } wtWebGraphAnalogIn57644StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StartMonth-January(1), wtWebGraphAnalogIn57644StartMonth-February(2), wtWebGraphAnalogIn57644StartMonth-March(3), wtWebGraphAnalogIn57644StartMonth-April(4), wtWebGraphAnalogIn57644StartMonth-May(5), wtWebGraphAnalogIn57644StartMonth-June(6), wtWebGraphAnalogIn57644StartMonth-July(7), wtWebGraphAnalogIn57644StartMonth-August(8), wtWebGraphAnalogIn57644StartMonth-September(9), wtWebGraphAnalogIn57644StartMonth-October(10), wtWebGraphAnalogIn57644StartMonth-November(11), wtWebGraphAnalogIn57644StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebGraphAnalogIn57644TimeZone 7 } wtWebGraphAnalogIn57644StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StartMode-first(1), wtWebGraphAnalogIn57644StartMode-second(2), wtWebGraphAnalogIn57644StartMode-third(3), wtWebGraphAnalogIn57644StartMode-fourth(4), wtWebGraphAnalogIn57644StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebGraphAnalogIn57644TimeZone 8 } wtWebGraphAnalogIn57644StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StartWday-Sunday(1), wtWebGraphAnalogIn57644StartWday-Monday(2), wtWebGraphAnalogIn57644StartWday-Tuesday(3), wtWebGraphAnalogIn57644StartWday-Thursday(4), wtWebGraphAnalogIn57644StartWday-Wednesday(5), wtWebGraphAnalogIn57644StartWday-Friday(6), wtWebGraphAnalogIn57644StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebGraphAnalogIn57644TimeZone 9 } wtWebGraphAnalogIn57644StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 10 } wtWebGraphAnalogIn57644StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 11 } wtWebGraphAnalogIn57644StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StopMonth-January(1), wtWebGraphAnalogIn57644StopMonth-February(2), wtWebGraphAnalogIn57644StopMonth-March(3), wtWebGraphAnalogIn57644StopMonth-April(4), wtWebGraphAnalogIn57644StopMonth-May(5), wtWebGraphAnalogIn57644StopMonth-June(6), wtWebGraphAnalogIn57644StopMonth-July(7), wtWebGraphAnalogIn57644StopMonth-August(8), wtWebGraphAnalogIn57644StopMonth-September(9), wtWebGraphAnalogIn57644StopMonth-October(10), wtWebGraphAnalogIn57644StopMonth-November(11), wtWebGraphAnalogIn57644StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57644TimeZone 12 } wtWebGraphAnalogIn57644StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StopMode-first(1), wtWebGraphAnalogIn57644StopMode-second(2), wtWebGraphAnalogIn57644StopMode-third(3), wtWebGraphAnalogIn57644StopMode-fourth(4), wtWebGraphAnalogIn57644StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57644TimeZone 13 } wtWebGraphAnalogIn57644StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644StopWday-Sunday(1), wtWebGraphAnalogIn57644StopWday-Monday(2), wtWebGraphAnalogIn57644StopWday-Tuesday(3), wtWebGraphAnalogIn57644StopWday-Thursday(4), wtWebGraphAnalogIn57644StopWday-Wednesday(5), wtWebGraphAnalogIn57644StopWday-Friday(6), wtWebGraphAnalogIn57644StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57644TimeZone 14 } wtWebGraphAnalogIn57644StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 15 } wtWebGraphAnalogIn57644StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalogIn57644TimeZone 16 } -- wtWebGraphAnalogIn57644TimeServer Group ---------------------------- wtWebGraphAnalogIn57644TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebGraphAnalogIn57644TimeServer 1 } wtWebGraphAnalogIn57644TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebGraphAnalogIn57644TimeServer 2 } wtWebGraphAnalogIn57644TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebGraphAnalogIn57644TimeServer 3 } wtWebGraphAnalogIn57644TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebGraphAnalogIn57644TimeServer 4 } -- wtWebGraphAnalogIn57644DeviceClock Group ---------------------------- wtWebGraphAnalogIn57644ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebGraphAnalogIn57644DeviceClock 1 } wtWebGraphAnalogIn57644ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebGraphAnalogIn57644DeviceClock 2 } wtWebGraphAnalogIn57644ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57644DeviceClock 3 } wtWebGraphAnalogIn57644ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644ClockMonth-January(1), wtWebGraphAnalogIn57644ClockMonth-February(2), wtWebGraphAnalogIn57644ClockMonth-March(3), wtWebGraphAnalogIn57644ClockMonth-April(4), wtWebGraphAnalogIn57644ClockMonth-May(5), wtWebGraphAnalogIn57644ClockMonth-June(6), wtWebGraphAnalogIn57644ClockMonth-July(7), wtWebGraphAnalogIn57644ClockMonth-August(8), wtWebGraphAnalogIn57644ClockMonth-September(9), wtWebGraphAnalogIn57644ClockMonth-October(10), wtWebGraphAnalogIn57644ClockMonth-November(11), wtWebGraphAnalogIn57644ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57644DeviceClock 4 } wtWebGraphAnalogIn57644ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57644DeviceClock 5 } -- wtWebGraphAnalogIn57644Network Group ------------------------ wtWebGraphAnalogIn57644IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebGraphAnalogIn57644Network 1 } wtWebGraphAnalogIn57644SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebGraphAnalogIn57644Network 2 } wtWebGraphAnalogIn57644Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebGraphAnalogIn57644Network 3 } wtWebGraphAnalogIn57644DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebGraphAnalogIn57644Network 4 } wtWebGraphAnalogIn57644DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebGraphAnalogIn57644Network 5 } wtWebGraphAnalogIn57644AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebGraphAnalogIn57644Network 6 } -- wtWebGraphAnalogIn57644HTTP Group -------------------------------- wtWebGraphAnalogIn57644Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebGraphAnalogIn57644HTTP 1 } wtWebGraphAnalogIn57644GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebGraphAnalogIn57644HTTP 2 } wtWebGraphAnalogIn57644HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebGraphAnalogIn57644HTTP 3 } -- wtWebGraphAnalogIn57644Mail Group -------------------------------- wtWebGraphAnalogIn57644MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebGraphAnalogIn57644Mail 1 } wtWebGraphAnalogIn57644MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebGraphAnalogIn57644Mail 2 } wtWebGraphAnalogIn57644MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebGraphAnalogIn57644Mail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebGraphAnalogIn57644Mail 4 } wtWebGraphAnalogIn57644MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebGraphAnalogIn57644Mail 5 } wtWebGraphAnalogIn57644MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebGraphAnalogIn57644Mail 6 } wtWebGraphAnalogIn57644MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebGraphAnalogIn57644Mail 7 } wtWebGraphAnalogIn57644MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebGraphAnalogIn57644Mail 8 } -- wtWebGraphAnalogIn57644SNMP Group -------------------------------- wtWebGraphAnalogIn57644SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebGraphAnalogIn57644SNMP 1 } wtWebGraphAnalogIn57644SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebGraphAnalogIn57644SNMP 2 } wtWebGraphAnalogIn57644SystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebGraphAnalogIn57644SNMP 3 } wtWebGraphAnalogIn57644SystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644SNMP 4 } wtWebGraphAnalogIn57644SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebGraphAnalogIn57644SNMP 5 } wtWebGraphAnalogIn57644SnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebGraphAnalogIn57644SNMP 6 } -- wtWebGraphAnalogIn57644UDP Group -------------------------------- wtWebGraphAnalogIn57644UdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebGraphAnalogIn57644UDP 1 } wtWebGraphAnalogIn57644UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebGraphAnalogIn57644UDP 2 } -- wtWebGraphAnalogIn57644Syslog Group -------------------------------- wtWebGraphAnalogIn57644SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebGraphAnalogIn57644Syslog 1 } wtWebGraphAnalogIn57644SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebGraphAnalogIn57644Syslog 2 } wtWebGraphAnalogIn57644SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebGraphAnalogIn57644Syslog 3 } wtWebGraphAnalogIn57644SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebGraphAnalogIn57644Syslog 4 } -- wtWebGraphAnalogIn57644FTP Group -------------------------------- wtWebGraphAnalogIn57644FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebGraphAnalogIn57644FTP 1 } wtWebGraphAnalogIn57644FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebGraphAnalogIn57644FTP 2 } wtWebGraphAnalogIn57644FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebGraphAnalogIn57644FTP 3 } wtWebGraphAnalogIn57644FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebGraphAnalogIn57644FTP 4 } wtWebGraphAnalogIn57644FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebGraphAnalogIn57644FTP 5 } wtWebGraphAnalogIn57644FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebGraphAnalogIn57644FTP 6 } wtWebGraphAnalogIn57644FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebGraphAnalogIn57644FTP 7 } -- wtWebGraphAnalogIn57644Datalogger Group -------------------------------- wtWebGraphAnalogIn57644LoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644Datalogger-1Min(1), wtWebGraphAnalogIn57644Datalogger-5Min(2), wtWebGraphAnalogIn57644Datalogger-15Min(3), wtWebGraphAnalogIn57644Datalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebGraphAnalogIn57644Datalogger 1 } wtWebGraphAnalogIn57644LoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644Datalogger 2 } wtWebGraphAnalogIn57644DisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644Datalogger 3 } -- Graph Sensor Color Table wtWebGraphAnalogIn57644SensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalogIn57644Datalogger 4 } wtWebGraphAnalogIn57644SensorColorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644SensorColorTable 1 } WtWebGraphAnalogIn57644SensorColorEntry ::= SEQUENCE { wtWebGraphAnalogIn57644SensorColor OCTET STRING } wtWebGraphAnalogIn57644SensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalogIn57644SensorColorEntry 1 } wtWebGraphAnalogIn57644AutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebGraphAnalogIn57644Datalogger 5 } wtWebGraphAnalogIn57644VerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644Datalogger 6 } wtWebGraphAnalogIn57644VerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644Datalogger 7 } wtWebGraphAnalogIn57644HorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57644Zoom-25min(1), wtWebGraphAnalogIn57644Zoom-75min(2), wtWebGraphAnalogIn57644Zoom-5hrs(3), wtWebGraphAnalogIn57644Zoom-30hrs(4), wtWebGraphAnalogIn57644Zoom-5days(5), wtWebGraphAnalogIn57644Zoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebGraphAnalogIn57644Datalogger 8 } -- wtWebGraphAnalogIn57644Alarm Group ---------------------------- wtWebGraphAnalogIn57644AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebGraphAnalogIn57644Alarm 1 } -- Alarm Interface Table wtWebGraphAnalogIn57644AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebGraphAnalogIn57644Alarm 2 } wtWebGraphAnalogIn57644AlarmIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebGraphAnalogIn57644AlarmNo } ::= { wtWebGraphAnalogIn57644AlarmIfTable 1 } WtWebGraphAnalogIn57644AlarmIfEntry ::= SEQUENCE { wtWebGraphAnalogIn57644AlarmNo INTEGER } wtWebGraphAnalogIn57644AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebGraphAnalogIn57644AlarmIfEntry 1 } -- Alarm Table wtWebGraphAnalogIn57644AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebGraphAnalogIn57644Alarm 3 } wtWebGraphAnalogIn57644AlarmEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebGraphAnalogIn57644AlarmNo } ::= { wtWebGraphAnalogIn57644AlarmTable 1 } WtWebGraphAnalogIn57644AlarmEntry ::= SEQUENCE { wtWebGraphAnalogIn57644AlarmTrigger OCTET STRING, wtWebGraphAnalogIn57644AlarmMin OCTET STRING, wtWebGraphAnalogIn57644AlarmMax OCTET STRING, wtWebGraphAnalogIn57644AlarmHysteresis OCTET STRING, wtWebGraphAnalogIn57644AlarmDelay OCTET STRING, wtWebGraphAnalogIn57644AlarmInterval OCTET STRING, wtWebGraphAnalogIn57644AlarmEnable OCTET STRING, wtWebGraphAnalogIn57644AlarmEMailAddr OCTET STRING, wtWebGraphAnalogIn57644AlarmMailSubject OCTET STRING, wtWebGraphAnalogIn57644AlarmMailText OCTET STRING, wtWebGraphAnalogIn57644AlarmManagerIP OCTET STRING, wtWebGraphAnalogIn57644AlarmTrapText OCTET STRING, wtWebGraphAnalogIn57644AlarmMailOptions OCTET STRING, wtWebGraphAnalogIn57644AlarmTcpIpAddr OCTET STRING, wtWebGraphAnalogIn57644AlarmTcpPort INTEGER, wtWebGraphAnalogIn57644AlarmTcpText OCTET STRING, wtWebGraphAnalogIn57644AlarmClearMailSubject OCTET STRING, wtWebGraphAnalogIn57644AlarmClearMailText OCTET STRING, wtWebGraphAnalogIn57644AlarmClearTrapText OCTET STRING, wtWebGraphAnalogIn57644AlarmClearTcpText OCTET STRING, wtWebGraphAnalogIn57644Alarm2Min OCTET STRING, wtWebGraphAnalogIn57644Alarm2Max OCTET STRING, wtWebGraphAnalogIn57644Alarm2Hysteresis OCTET STRING, wtWebGraphAnalogIn57644AlarmSyslogIpAddr OCTET STRING, wtWebGraphAnalogIn57644AlarmSyslogPort INTEGER, wtWebGraphAnalogIn57644AlarmSyslogText OCTET STRING, wtWebGraphAnalogIn57644AlarmSyslogClearText OCTET STRING, wtWebGraphAnalogIn57644AlarmFtpDataPort OCTET STRING, wtWebGraphAnalogIn57644AlarmFtpFileName OCTET STRING, wtWebGraphAnalogIn57644AlarmFtpText OCTET STRING, wtWebGraphAnalogIn57644AlarmFtpClearText OCTET STRING, wtWebGraphAnalogIn57644AlarmFtpOption OCTET STRING, wtWebGraphAnalogIn57644AlarmTimerCron OCTET STRING } wtWebGraphAnalogIn57644AlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644AlarmEntry 1 } wtWebGraphAnalogIn57644AlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 2 } wtWebGraphAnalogIn57644AlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 3 } wtWebGraphAnalogIn57644AlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 4 } wtWebGraphAnalogIn57644AlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebGraphAnalogIn57644AlarmEntry 5 } wtWebGraphAnalogIn57644AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebGraphAnalogIn57644AlarmEntry 6 } wtWebGraphAnalogIn57644AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebGraphAnalogIn57644AlarmEntry 7 } wtWebGraphAnalogIn57644AlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebGraphAnalogIn57644AlarmEntry 8 } wtWebGraphAnalogIn57644AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebGraphAnalogIn57644AlarmEntry 9 } wtWebGraphAnalogIn57644AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebGraphAnalogIn57644AlarmEntry 10 } wtWebGraphAnalogIn57644AlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebGraphAnalogIn57644AlarmEntry 11 } wtWebGraphAnalogIn57644AlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalogIn57644AlarmEntry 12 } wtWebGraphAnalogIn57644AlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644AlarmEntry 13 } wtWebGraphAnalogIn57644AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebGraphAnalogIn57644AlarmEntry 14 } wtWebGraphAnalogIn57644AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebGraphAnalogIn57644AlarmEntry 15 } wtWebGraphAnalogIn57644AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalogIn57644AlarmEntry 16 } wtWebGraphAnalogIn57644AlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebGraphAnalogIn57644AlarmEntry 17 } wtWebGraphAnalogIn57644AlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebGraphAnalogIn57644AlarmEntry 18 } wtWebGraphAnalogIn57644AlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalogIn57644AlarmEntry 19 } wtWebGraphAnalogIn57644AlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalogIn57644AlarmEntry 20 } wtWebGraphAnalogIn57644Alarm2Min OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum rel. Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 21 } wtWebGraphAnalogIn57644Alarm2Max OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum rel.Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 22 } wtWebGraphAnalogIn57644Alarm2Hysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hysterese rel. Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644AlarmEntry 23 } wtWebGraphAnalogIn57644AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalogIn57644AlarmEntry 24 } wtWebGraphAnalogIn57644AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalogIn57644AlarmEntry 25 } wtWebGraphAnalogIn57644AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebGraphAnalogIn57644AlarmEntry 26 } wtWebGraphAnalogIn57644AlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message." ::= { wtWebGraphAnalogIn57644AlarmEntry 27 } wtWebGraphAnalogIn57644AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebGraphAnalogIn57644AlarmEntry 28 } wtWebGraphAnalogIn57644AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebGraphAnalogIn57644AlarmEntry 29 } wtWebGraphAnalogIn57644AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebGraphAnalogIn57644AlarmEntry 30 } wtWebGraphAnalogIn57644AlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebGraphAnalogIn57644AlarmEntry 31 } wtWebGraphAnalogIn57644AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644AlarmEntry 32 } wtWebGraphAnalogIn57644AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebGraphAnalogIn57644AlarmEntry 33 } -- wtWebGraphAnalogIn57644GraphicsBase Group ---------------------------- wtWebGraphAnalogIn57644GraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebGraphAnalogIn57644GraphicsBase 1 } wtWebGraphAnalogIn57644GraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebGraphAnalogIn57644GraphicsBase 2 } wtWebGraphAnalogIn57644GraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebGraphAnalogIn57644GraphicsBase 3 } wtWebGraphAnalogIn57644GraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebGraphAnalogIn57644GraphicsBase 4 } wtWebGraphAnalogIn57644GraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebGraphAnalogIn57644GraphicsBase 5 } wtWebGraphAnalogIn57644GraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebGraphAnalogIn57644GraphicsBase 6 } -- wtWebGraphAnalogIn57644GraphicsSelect Group ---------------------------- wtWebGraphAnalogIn57644GraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebGraphAnalogIn57644GraphicsSelect 1 } wtWebGraphAnalogIn57644GraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebGraphAnalogIn57644GraphicsSelect 2 } -- Graph Sensor Color Table wtWebGraphAnalogIn57644SensorColor2Table OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalogIn57644GraphicsSelect 3 } wtWebGraphAnalogIn57644SensorColor2Entry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644SensorColor2Table 1 } WtWebGraphAnalogIn57644SensorColor2Entry ::= SEQUENCE { wtWebGraphAnalogIn57644GraphicsSensorColor OCTET STRING, wtWebGraphAnalogIn57644GraphicsSelectScale OCTET STRING } wtWebGraphAnalogIn57644GraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalogIn57644SensorColor2Entry 1 } wtWebGraphAnalogIn57644GraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unused" ::= { wtWebGraphAnalogIn57644SensorColor2Entry 2 } -- wtWebGraphAnalogIn57644GraphicsScale Group ---------------------------- wtWebGraphAnalogIn57644GraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unused" ::= { wtWebGraphAnalogIn57644GraphicsScale 1 } wtWebGraphAnalogIn57644GraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unused" ::= { wtWebGraphAnalogIn57644GraphicsScale 2 } wtWebGraphAnalogIn57644GraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebGraphAnalogIn57644GraphicsScale 3 } wtWebGraphAnalogIn57644GraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebGraphAnalogIn57644GraphicsScale 4 } wtWebGraphAnalogIn57644GraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Minimum." ::= { wtWebGraphAnalogIn57644GraphicsScale 5 } wtWebGraphAnalogIn57644GraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Minimum." ::= { wtWebGraphAnalogIn57644GraphicsScale 6 } wtWebGraphAnalogIn57644GraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebGraphAnalogIn57644GraphicsScale 7 } wtWebGraphAnalogIn57644GraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebGraphAnalogIn57644GraphicsScale 8 } wtWebGraphAnalogIn57644GraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Maximum." ::= { wtWebGraphAnalogIn57644GraphicsScale 9 } wtWebGraphAnalogIn57644GraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Maximum." ::= { wtWebGraphAnalogIn57644GraphicsScale 10 } wtWebGraphAnalogIn57644GraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebGraphAnalogIn57644GraphicsScale 11 } wtWebGraphAnalogIn57644GraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebGraphAnalogIn57644GraphicsScale 12 } wtWebGraphAnalogIn57644GraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Unit." ::= { wtWebGraphAnalogIn57644GraphicsScale 13 } wtWebGraphAnalogIn57644GraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Unit." ::= { wtWebGraphAnalogIn57644GraphicsScale 14 } -- wtWebGraphAnalogIn57644Ports Group ---------------------------- -- Table wtWebGraphAnalogIn57644PortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57644PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebGraphAnalogIn57644Ports 1 } wtWebGraphAnalogIn57644PortEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57644PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebGraphAnalogIn57644SensorNo } ::= { wtWebGraphAnalogIn57644PortTable 1 } WtWebGraphAnalogIn57644PortEntry ::= SEQUENCE { wtWebGraphAnalogIn57644PortName OCTET STRING, wtWebGraphAnalogIn57644PortText OCTET STRING, wtWebGraphAnalogIn57644PortOffset1 OCTET STRING, wtWebGraphAnalogIn57644SetPoint1 OCTET STRING, wtWebGraphAnalogIn57644PortOffset2 OCTET STRING, wtWebGraphAnalogIn57644SetPoint2 OCTET STRING, wtWebGraphAnalogIn57644PortComment OCTET STRING, wtWebGraphAnalogIn57644PortSensorSelect OCTET STRING, wtWebGraphAnalogIn57644PortUnit OCTET STRING, wtWebGraphAnalogIn57644PortScale0 OCTET STRING, wtWebGraphAnalogIn57644PortScale100 OCTET STRING } wtWebGraphAnalogIn57644PortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebGraphAnalogIn57644PortEntry 1 } wtWebGraphAnalogIn57644PortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebGraphAnalogIn57644PortEntry 2 } wtWebGraphAnalogIn57644PortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at set point 1." ::= { wtWebGraphAnalogIn57644PortEntry 3 } wtWebGraphAnalogIn57644SetPoint1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: set point 1 in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644PortEntry 4 } wtWebGraphAnalogIn57644PortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at set point 2." ::= { wtWebGraphAnalogIn57644PortEntry 5 } wtWebGraphAnalogIn57644SetPoint2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: set point 2 in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57644PortEntry 6 } wtWebGraphAnalogIn57644PortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebGraphAnalogIn57644PortEntry 7 } wtWebGraphAnalogIn57644PortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-10V (default) Bit 1 : Disconnect Bit 2-7: unused Binary coded options for sensor 2: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-10V (default) Bit 1 : Disconnect Bit 2-7: unused" ::= { wtWebGraphAnalogIn57644PortEntry 8 } wtWebGraphAnalogIn57644PortUnit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed unit." ::= { wtWebGraphAnalogIn57644PortEntry 9 } wtWebGraphAnalogIn57644PortScale0 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalogIn57644PortEntry 10 } wtWebGraphAnalogIn57644PortScale100 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalogIn57644PortEntry 11 } -- wtWebGraphAnalogIn57644Manufact Group ---------------------------- wtWebGraphAnalogIn57644MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebGraphAnalogIn57644Manufact 1 } wtWebGraphAnalogIn57644MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebGraphAnalogIn57644Manufact 2 } wtWebGraphAnalogIn57644MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebGraphAnalogIn57644Manufact 3 } wtWebGraphAnalogIn57644MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebGraphAnalogIn57644Manufact 4 } wtWebGraphAnalogIn57644MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebGraphAnalogIn57644Manufact 5 } wtWebGraphAnalogIn57644MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebGraphAnalogIn57644Manufact 6 } -- wtWebGraphAnalogIn57644Diag Group ---------------------------- wtWebGraphAnalogIn57644DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebGraphAnalogIn57644Diag 1 } wtWebGraphAnalogIn57644DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebGraphAnalogIn57644Diag 2 } wtWebGraphAnalogIn57644DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebGraphAnalogIn57644DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAnalogIn57644DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAnalogIn57644DiagErrorMessage." ::= { wtWebGraphAnalogIn57644Diag 3 } wtWebGraphAnalogIn57644DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebGraphAnalogIn57644DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebGraphAnalogIn57644Diag 4 } wtWebGraphAnalogIn57644DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebGraphAnalogIn57644Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebGraphAnalogIn57644Alert1 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebGraphAnalogIn57644Alert2 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebGraphAnalogIn57644Alert3 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebGraphAnalogIn57644Alert4 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebGraphAnalogIn57644Alert5 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebGraphAnalogIn57644Alert6 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebGraphAnalogIn57644Alert7 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebGraphAnalogIn57644Alert8 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebGraphAnalogIn57644Alert9 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebGraphAnalogIn57644Alert10 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebGraphAnalogIn57644Alert11 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebGraphAnalogIn57644Alert12 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebGraphAnalogIn57644Alert13 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebGraphAnalogIn57644Alert14 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebGraphAnalogIn57644Alert15 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebGraphAnalogIn57644Alert16 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebGraphAnalogIn57644AlertDiag TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57644 VARIABLES { wtWebGraphAnalogIn57644DiagErrorIndex, wtWebGraphAnalogIn57644DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END