TERACOM-TCW240B-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprises, IpAddress, Integer32, snmpModules FROM SNMPv2-SMI DateAndTime, MacAddress, DisplayString FROM SNMPv2-TC TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP , NOTIFICATION-GROUP FROM SNMPv2-CONF; snmpMIB MODULE-IDENTITY LAST-UPDATED "20160823000Z" ORGANIZATION "TERACOM" CONTACT-INFO "EMail: info@teracom.cc" DESCRIPTION "The MIB module for TCW240 SNMP entities." REVISION "20160823000Z" DESCRIPTION "TCW240bv1.18" ::= { snmpModules 1 } teracom OBJECT IDENTIFIER ::= { enterprises 38783 } tcw240b OBJECT IDENTIFIER ::= { teracom 1 } trapNotifications OBJECT IDENTIFIER ::= { tcw240b 0 } product OBJECT IDENTIFIER ::= { tcw240b 1 } setup OBJECT IDENTIFIER ::= { tcw240b 2 } monitorNcontrol OBJECT IDENTIFIER ::= { tcw240b 3 } tcw240bMIBConformance OBJECT IDENTIFIER ::= { tcw240b 4 } tcw240bMIBCompliances OBJECT IDENTIFIER ::= { tcw240bMIBConformance 1 } tcw240bMIBGroups OBJECT IDENTIFIER ::= { tcw240bMIBConformance 2 } CONTROLLED ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This textual convention enumerates the authentication and privledge protocol for USM configuration. " SYNTAX INTEGER { manual(0),sensor11(1),sensor21(2),sensor31(3),sensor41(4), sensor51(5),sensor61(6),sensor71(7),sensor81(8),sensor12(9), sensor22(10),sensor32(11),sensor42(12),sensor52(13),sensor62(14), sensor72(15),sensor82(16),analog1(17),analog2(18),analog3(19),analog4(20), digital1(21),digital2(22),digital3(23),digital4(24), scheduler1(25),scheduler2(26),scheduler3(27),scheduler4(28) } name OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Name of product. e.g. teracom.cc etc." ::= { product 1 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version string. e.g. 1.0" ::= { product 2 } dateTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "Date and time" ::= { product 3 } network OBJECT IDENTIFIER ::= { setup 1 } deviceID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Device ID is Default MAC Address" ::= { network 1 } hostName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..38)) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Name" ::= { network 2 } deviceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Device IP Address" ::= { network 3 } io OBJECT IDENTIFIER ::= { setup 2 } sensorsSetup OBJECT IDENTIFIER ::= { io 1 } sensor1setup OBJECT IDENTIFIER ::= { sensorsSetup 1 } sensor2setup OBJECT IDENTIFIER ::= { sensorsSetup 2 } sensor3setup OBJECT IDENTIFIER ::= { sensorsSetup 3 } sensor4setup OBJECT IDENTIFIER ::= { sensorsSetup 4 } sensor5setup OBJECT IDENTIFIER ::= { sensorsSetup 5 } sensor6setup OBJECT IDENTIFIER ::= { sensorsSetup 6 } sensor7setup OBJECT IDENTIFIER ::= { sensorsSetup 7 } sensor8setup OBJECT IDENTIFIER ::= { sensorsSetup 8 } --CONTROLLED ::= Integer32 { manual(0),sensor11(1),sensor21(2),sensor31(3),sensor41(4),sensor51(5),sensor61(6),sensor71(7),sensor81(8),sensor12(9),sensor22(10),sensor32(11),sensor42(12),sensor52(13),sensor62(14),sensor72(15),sensor82(16),analog1(17),analog2(18),analog3(19),analog4(20),digital1(21),digital2(22),digital3(23),digital4(24),scheduler1(25),scheduler2(26),scheduler3(27),scheduler4(28) } s1description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sensor1 description" ::= { sensor1setup 1 } sensor11setup OBJECT IDENTIFIER ::= { sensor1setup 2 } sensor12setup OBJECT IDENTIFIER ::= { sensor1setup 3 } s11MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S11 maximum value x10 in Integer format" ::= { sensor11setup 1 } s11MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S11 minimum value x10 in Integer format" ::= { sensor11setup 2 } s11HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S11 hysteresis value x10 in Integer format" ::= { sensor11setup 3 } s12MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S12 maximum value x10 in Integer format" ::= { sensor12setup 1 } s12MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S12 minimum value x10 in Integer format" ::= { sensor12setup 2 } s12HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "S12 hysteresis value x10 in Integer format" ::= { sensor12setup 3 } s2description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor2 description" ::= { sensor2setup 1 } sensor21setup OBJECT IDENTIFIER ::= { sensor2setup 2 } sensor22setup OBJECT IDENTIFIER ::= { sensor2setup 3 } s21MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s21 maximum value x10 in Integer format" ::= { sensor21setup 1 } s21MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s21 minimum value x10 in Integer format" ::= { sensor21setup 2 } s21HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s21 hysteresis value x10 in Integer format" ::= { sensor21setup 3 } s22MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s22 maximum value x10 in Integer format" ::= { sensor22setup 1 } s22MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s22 minimum value x10 in Integer format" ::= { sensor22setup 2 } s22HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s22 hysteresis value x10 in Integer format" ::= { sensor22setup 3 } s3description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor3 description" ::= { sensor3setup 1 } sensor31setup OBJECT IDENTIFIER ::= { sensor3setup 2 } sensor32setup OBJECT IDENTIFIER ::= { sensor3setup 3 } s31MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s31 maximum value x10 in Integer format" ::= { sensor31setup 1 } s31MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s31 minimum value x10 in Integer format" ::= { sensor31setup 2 } s31HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s31 hysteresis value x10 in Integer format" ::= { sensor31setup 3 } s32MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s32 maximum value x10 in Integer format" ::= { sensor32setup 1 } s32MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s32 minimum value x10 in Integer format" ::= { sensor32setup 2 } s32HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s32 hysteresis value x10 in Integer format" ::= { sensor32setup 3 } s4description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor4 description" ::= { sensor4setup 1 } sensor41setup OBJECT IDENTIFIER ::= { sensor4setup 2 } sensor42setup OBJECT IDENTIFIER ::= { sensor4setup 3 } s41MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s41 maximum value x10 in Integer format" ::= { sensor41setup 1 } s41MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s41 minimum value x10 in Integer format" ::= { sensor41setup 2 } s41HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s41 hysteresis value x10 in Integer format" ::= { sensor41setup 3 } s42MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s42 maximum value x10 in Integer format" ::= { sensor42setup 1 } s42MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s42 minimum value x10 in Integer format" ::= { sensor42setup 2 } s42HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s42 hysteresis value x10 in Integer format" ::= { sensor42setup 3 } s5description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor5 description" ::= { sensor5setup 1 } sensor51setup OBJECT IDENTIFIER ::= { sensor5setup 2 } sensor52setup OBJECT IDENTIFIER ::= { sensor5setup 3 } s51MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s51 maximum value x10 in Integer format" ::= { sensor51setup 1 } s51MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s51 minimum value x10 in Integer format" ::= { sensor51setup 2 } s51HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s51 hysteresis value x10 in Integer format" ::= { sensor51setup 3 } s52MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s52 maximum value x10 in Integer format" ::= { sensor52setup 1 } s52MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s52 minimum value x10 in Integer format" ::= { sensor52setup 2 } s52HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s52 hysteresis value x10 in Integer format" ::= { sensor52setup 3 } s6description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor6 description" ::= { sensor6setup 1 } sensor61setup OBJECT IDENTIFIER ::= { sensor6setup 2 } sensor62setup OBJECT IDENTIFIER ::= { sensor6setup 3 } s61MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s61 maximum value x10 in Integer format" ::= { sensor61setup 1 } s61MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s61 minimum value x10 in Integer format" ::= { sensor61setup 2 } s61HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s61 hysteresis value x10 in Integer format" ::= { sensor61setup 3 } s62MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s62 maximum value x10 in Integer format" ::= { sensor62setup 1 } s62MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s62 minimum value x10 in Integer format" ::= { sensor62setup 2 } s62HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s62 hysteresis value x10 in Integer format" ::= { sensor62setup 3 } s7description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor7 description" ::= { sensor7setup 1 } sensor71setup OBJECT IDENTIFIER ::= { sensor7setup 2 } sensor72setup OBJECT IDENTIFIER ::= { sensor7setup 3 } s71MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s71 maximum value x10 in Integer format" ::= { sensor71setup 1 } s71MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s71 minimum value x10 in Integer format" ::= { sensor71setup 2 } s71HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s71 hysteresis value x10 in Integer format" ::= { sensor71setup 3 } s72MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s72 maximum value x10 in Integer format" ::= { sensor72setup 1 } s72MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s72 minimum value x10 in Integer format" ::= { sensor72setup 2 } s72HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s72 hysteresis value x10 in Integer format" ::= { sensor72setup 3 } s8description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "sensor8 description" ::= { sensor8setup 1 } sensor81setup OBJECT IDENTIFIER ::= { sensor8setup 2 } sensor82setup OBJECT IDENTIFIER ::= { sensor8setup 3 } s81MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s81 maximum value x10 in Integer format" ::= { sensor81setup 1 } s81MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s81 minimum value x10 in Integer format" ::= { sensor81setup 2 } s81HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s81 hysteresis value x10 in Integer format" ::= { sensor81setup 3 } s82MAXx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s82 maximum value x10 in Integer format" ::= { sensor82setup 1 } s82MINx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s82 minimum value x10 in Integer format" ::= { sensor82setup 2 } s82HYSTx10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "s82 hysteresis value x10 in Integer format" ::= { sensor82setup 3 } analogSetup OBJECT IDENTIFIER ::= { io 2 } analog1setup OBJECT IDENTIFIER ::= { analogSetup 1 } analog2setup OBJECT IDENTIFIER ::= { analogSetup 2 } analog3setup OBJECT IDENTIFIER ::= { analogSetup 3 } analog4setup OBJECT IDENTIFIER ::= { analogSetup 4 } voltage1description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 1 description" ::= { analog1setup 1 } voltage1max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 1 maximum" ::= { analog1setup 2 } voltage1min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 1 minimum" ::= { analog1setup 3 } voltage1hyst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 1 hysteresis" ::= { analog1setup 4 } voltage2description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 2 description" ::= { analog2setup 1 } voltage2max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 2 maximum" ::= { analog2setup 2 } voltage2min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 2 minimum" ::= { analog2setup 3 } voltage2hyst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 2 hysteresis" ::= { analog2setup 4 } voltage3description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 3 description" ::= { analog3setup 1 } voltage3max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 3 maximum" ::= { analog3setup 2 } voltage3min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 3 minimum" ::= { analog3setup 3 } voltage3hyst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 3 hysteresis" ::= { analog3setup 4 } voltage4description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 4 description" ::= { analog4setup 1 } voltage4max OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 4 maximum" ::= { analog4setup 2 } voltage4min OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 4 minimum" ::= { analog4setup 3 } voltage4hyst OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Voltage 4 hysteresis" ::= { analog4setup 4 } digitalSetup OBJECT IDENTIFIER ::= { io 3 } digitalInput1description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Digital Input 1 description" ::= { digitalSetup 1 } digitalInput2description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Digital Input 2 description" ::= { digitalSetup 2 } digitalInput3description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Digital Input 3 description" ::= { digitalSetup 3 } digitalInput4description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Digital Input 4 description" ::= { digitalSetup 4 } relaysSetup OBJECT IDENTIFIER ::= { io 4 } relay1setup OBJECT IDENTIFIER ::= { relaysSetup 1 } relay2setup OBJECT IDENTIFIER ::= { relaysSetup 2 } relay3setup OBJECT IDENTIFIER ::= { relaysSetup 3 } relay4setup OBJECT IDENTIFIER ::= { relaysSetup 4 } relay1description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 1 description" ::= { relay1setup 1 } relay1pulseWidth OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay1 Pulse x100ms" ::= { relay1setup 2 } relay1controlledBy OBJECT-TYPE SYNTAX CONTROLLED MAX-ACCESS read-write STATUS current DESCRIPTION "Relay1 control logic" ::= { relay1setup 3 } relay2description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 2 description" ::= { relay2setup 1 } relay2pulseWidth OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay2 Pulse x100ms" ::= { relay2setup 2 } relay2controlledBy OBJECT-TYPE SYNTAX CONTROLLED MAX-ACCESS read-write STATUS current DESCRIPTION "Relay2 control logic" ::= { relay2setup 3 } relay3description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 3 description" ::= { relay3setup 1 } relay3pulseWidth OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay3 Pulse x100ms" ::= { relay3setup 2 } relay3controlledBy OBJECT-TYPE SYNTAX CONTROLLED MAX-ACCESS read-write STATUS current DESCRIPTION "Relay3 control logic" ::= { relay3setup 3 } relay4description OBJECT-TYPE SYNTAX DisplayString (SIZE (0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay 4 description" ::= { relay4setup 1 } relay4pulseWidth OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Relay4 Pulse x100ms" ::= { relay4setup 2 } relay4controlledBy OBJECT-TYPE SYNTAX CONTROLLED MAX-ACCESS read-write STATUS current DESCRIPTION "Relay4 control logic" ::= { relay4setup 3 } sensors OBJECT IDENTIFIER ::= { monitorNcontrol 1 } sensor1 OBJECT IDENTIFIER ::= { sensors 1 } s11x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S11 value x10 in Integer format" ::= { sensor1 1 } s12x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S12 value x10 in Integer format" ::= { sensor1 2 } s1ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S1 ID value" ::= { sensor1 3 } sensor2 OBJECT IDENTIFIER ::= { sensors 2 } s21x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S21 value x10 in Integer format" ::= { sensor2 1 } s22x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S22 value x10 in Integer format" ::= { sensor2 2 } s2ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S2 ID value" ::= { sensor2 3 } sensor3 OBJECT IDENTIFIER ::= { sensors 3 } s31x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S31 value x10 in Integer format" ::= { sensor3 1 } s32x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S32 value x10 in Integer format" ::= { sensor3 2 } s3ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S3 ID value" ::= { sensor3 3 } sensor4 OBJECT IDENTIFIER ::= { sensors 4 } s41x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S41 value x10 in Integer format" ::= { sensor4 1 } s42x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S42 value x10 in Integer format" ::= { sensor4 2 } s4ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S4 ID value" ::= { sensor4 3 } sensor5 OBJECT IDENTIFIER ::= { sensors 5 } s51x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S51 value x10 in Integer format" ::= { sensor5 1 } s52x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S52 value x10 in Integer format" ::= { sensor5 2 } s5ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S5 ID value" ::= { sensor5 3 } sensor6 OBJECT IDENTIFIER ::= { sensors 6 } s61x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S61 value x10 in Integer format" ::= { sensor6 1 } s62x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S62 value x10 in Integer format" ::= { sensor6 2 } s6ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S6 ID value" ::= { sensor6 3 } sensor7 OBJECT IDENTIFIER ::= { sensors 7 } s71x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S71 value x10 in Integer format" ::= { sensor7 1 } s72x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S72 value x10 in Integer format" ::= { sensor7 2 } s7ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S7 ID value" ::= { sensor7 3 } sensor8 OBJECT IDENTIFIER ::= { sensors 8 } s81x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S81 value x10 in Integer format" ::= { sensor8 1 } s82x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "S82 value x10 in Integer format" ::= { sensor8 2 } s8ID OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "S8 ID value" ::= { sensor8 3 } analog OBJECT IDENTIFIER ::= { monitorNcontrol 2 } voltage1x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage1 x10 in Integer format" ::= { analog 1 } voltage2x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage2 x10 in Integer format" ::= { analog 2 } voltage3x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage3 x10 in Integer format" ::= { analog 3 } voltage4x10Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage4 x10 in Integer format" ::= { analog 4 } voltage1x100Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage1 x100 in Integer format" ::= { analog 5 } voltage2x100Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage2 x100 in Integer format" ::= { analog 6 } voltage3x100Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage3 x100 in Integer format" ::= { analog 7 } voltage4x100Int OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage4 x100 in Integer format" ::= { analog 8 } digital OBJECT IDENTIFIER ::= { monitorNcontrol 3 } digitalInput1State OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Digital1 Input State" ::= { digital 1 } digitalInput2State OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Digital2 Input State" ::= { digital 2 } digitalInput3State OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Digital3 Input State" ::= { digital 3 } digitalInput4State OBJECT-TYPE SYNTAX INTEGER { closed(0), open(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Digital4 Input State" ::= { digital 4 } relays OBJECT IDENTIFIER ::= { monitorNcontrol 4 } relay1 OBJECT IDENTIFIER ::= { relays 1 } relay1State OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay1 State" ::= { relay1 1 } relay1Pulse OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay1 Pulse" ::= { relay1 2 } relay2 OBJECT IDENTIFIER ::= { relays 2 } relay2State OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay2 State" ::= { relay2 1 } relay2Pulse OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay2 Pulse" ::= { relay2 2 } relay3 OBJECT IDENTIFIER ::= { relays 3 } relay3State OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay3 State" ::= { relay3 1 } relay3Pulse OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay3 Pulse" ::= { relay3 2 } relay4 OBJECT IDENTIFIER ::= { relays 4 } relay4State OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay4 State" ::= { relay4 1 } relay4Pulse OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Relay4 Pulse" ::= { relay4 2 } --- configurationSaved configurationSaved OBJECT-TYPE SYNTAX INTEGER { unsaved(0), saved(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Configuration save status SAVED/UNSAVED" ::= { monitorNcontrol 5 } restartDevice OBJECT-TYPE SYNTAX INTEGER { cancel(0), restart(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Restart Device" ::= { monitorNcontrol 6} temperatureUnit OBJECT-TYPE SYNTAX INTEGER { celcius(0), fahrenheit(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Unit of the all temperature values" ::= { monitorNcontrol 7} hardwareErr OBJECT-TYPE SYNTAX INTEGER { noErr(0), owErr(1), hwErr(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Error" ::= { monitorNcontrol 8} snmp-trap-notification NOTIFICATION-TYPE OBJECTS { digitalInput1State,digitalInput2State,digitalInput3State,digitalInput4State, voltage1x10Int,voltage2x10Int,voltage3x10Int,voltage4x10Int, s11x10Int,s12x10Int, s21x10Int,s22x10Int, s31x10Int,s32x10Int, s41x10Int,s42x10Int, s51x10Int,s52x10Int, s61x10Int,s62x10Int, s71x10Int,s72x10Int, s81x10Int,s82x10Int, restartDevice} STATUS current DESCRIPTION "SMIV2 Trap notification information for the SNMP Manager." ::= {trapNotifications 1} tcw240bMIBCompliances1 MODULE-COMPLIANCE STATUS current DESCRIPTION "This group is for SNMP applications." MODULE -- this module MANDATORY-GROUPS { tcw240bProductGroup, tcw240bSetupGroup, tcw240bMonitorGroup, tcw240bTrapGroup} ::= { tcw240bMIBCompliances 1 } tcw240bProductGroup OBJECT-GROUP OBJECTS {name, version, dateTime} STATUS current DESCRIPTION "A collection of objects providing basic product info." ::= { tcw240bMIBGroups 1 } tcw240bSetupGroup OBJECT-GROUP OBJECTS { deviceID, hostName, deviceIP, s1description, s11MAXx10Int, s11MINx10Int, s11HYSTx10Int, s12MAXx10Int, s12MINx10Int, s12HYSTx10Int, s2description, s21MAXx10Int, s21MINx10Int, s21HYSTx10Int, s22MAXx10Int, s22MINx10Int, s22HYSTx10Int, s3description, s31MAXx10Int, s31MINx10Int, s31HYSTx10Int, s32MAXx10Int, s32MINx10Int, s32HYSTx10Int, s4description, s41MAXx10Int, s41MINx10Int, s41HYSTx10Int, s42MAXx10Int, s42MINx10Int, s42HYSTx10Int, s5description, s51MAXx10Int, s51MINx10Int, s51HYSTx10Int, s52MAXx10Int, s52MINx10Int, s52HYSTx10Int, s6description, s61MAXx10Int, s61MINx10Int, s61HYSTx10Int, s62MAXx10Int, s62MINx10Int, s62HYSTx10Int, s7description, s71MAXx10Int, s71MINx10Int, s71HYSTx10Int, s72MAXx10Int, s72MINx10Int, s72HYSTx10Int, s8description, s81MAXx10Int, s81MINx10Int, s81HYSTx10Int, s82MAXx10Int, s82MINx10Int, s82HYSTx10Int, voltage1description, voltage1max, voltage1min, voltage1hyst, voltage2description, voltage2max, voltage2min, voltage2hyst, voltage3description, voltage3max, voltage3min, voltage3hyst, voltage4description, voltage4max, voltage4min, voltage4hyst, digitalInput1description, digitalInput2description, digitalInput3description, digitalInput4description, relay1description, relay1pulseWidth, relay1controlledBy, relay2description, relay2pulseWidth, relay2controlledBy, relay3description, relay3pulseWidth, relay3controlledBy, relay4description, relay4pulseWidth, relay4controlledBy } STATUS current DESCRIPTION "A collection of objects providing basic setup." ::= { tcw240bMIBGroups 2 } tcw240bMonitorGroup OBJECT-GROUP OBJECTS { s11x10Int, s12x10Int, s1ID, s21x10Int, s22x10Int, s2ID, s31x10Int, s32x10Int, s3ID, s41x10Int, s42x10Int, s4ID, s51x10Int, s52x10Int, s5ID, s61x10Int, s62x10Int, s6ID, s71x10Int, s72x10Int, s7ID, s81x10Int, s82x10Int, s8ID, voltage1x10Int, voltage2x10Int, voltage3x10Int, voltage4x10Int, voltage1x100Int, voltage2x100Int, voltage3x100Int, voltage4x100Int, digitalInput1State, digitalInput2State, digitalInput3State, digitalInput4State, relay1State, relay1Pulse, relay2State, relay2Pulse, relay3State, relay3Pulse, relay4State, relay4Pulse, configurationSaved, restartDevice, temperatureUnit, hardwareErr } STATUS current DESCRIPTION "A collection of objects providing basic monitoring and control of a product." ::= { tcw240bMIBGroups 3 } tcw240bTrapGroup NOTIFICATION-GROUP NOTIFICATIONS {snmp-trap-notification} STATUS current DESCRIPTION "SNMP Trap Notification object." ::= { tcw240bMIBGroups 4 } END