BAY-STACK-STORM-CONTROL-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, Integer32, Unsigned32 FROM SNMPv2-SMI TruthValue, TimeInterval FROM SNMPv2-TC InterfaceIndex, ifIndex FROM IF-MIB bayStackMibs FROM SYNOPTICS-ROOT-MIB; bayStackStormControlMib MODULE-IDENTITY LAST-UPDATED "201403040000Z" ORGANIZATION "Avaya" CONTACT-INFO "avaya.com" DESCRIPTION "This MIB module is used for Storm Control configuration. The Storm Control feature prevents traffic on a LAN from being disrupted by a broadcast, multicast, or unicast storm on an interface." REVISION "201403040000Z" -- March 4, 2014 DESCRIPTION "Ver 2: Changed syntax for bsStormControlTrafficType." REVISION "201206050000Z" -- June 5, 2012 DESCRIPTION "Ver 1: Initial version." ::= { bayStackMibs 42 } bsStormControlNotifications OBJECT IDENTIFIER ::= { bayStackStormControlMib 0 } bsStormControlObjects OBJECT IDENTIFIER ::= { bayStackStormControlMib 1 } bsStormControlScalars OBJECT IDENTIFIER ::= { bsStormControlObjects 1 } -- -- Storm control global objects -- bsStormControlPollValue OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The polled value when a notification is generated." ::= { bsStormControlScalars 1 } -- -- Storm control global configuration objects by traffic type. -- bsStormControlTable OBJECT-TYPE SYNTAX SEQUENCE OF BsStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to configure storm control global settings." ::= { bsStormControlObjects 2 } bsStormControlEntry OBJECT-TYPE SYNTAX BsStormControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing objects for controlling storm control settings." INDEX { bsStormControlTrafficType } ::= { bsStormControlTable 1 } BsStormControlEntry ::= SEQUENCE { bsStormControlTrafficType INTEGER, bsStormControlEnabled TruthValue, bsStormControlLowWatermark Unsigned32, bsStormControlHighWatermark Unsigned32, bsStormControlPollInterval TimeInterval, bsStormControlTrapInterval Integer32, bsStormControlActionType INTEGER } bsStormControlTrafficType OBJECT-TYPE SYNTAX INTEGER { unicast(1), broadcast(2), multicast(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Storm control traffic type." ::= { bsStormControlEntry 1 } bsStormControlEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether storm control is enabled for this instance." ::= { bsStormControlEntry 2 } bsStormControlLowWatermark OBJECT-TYPE SYNTAX Unsigned32 (10..100000000) UNITS "packets per second" MAX-ACCESS read-write STATUS current DESCRIPTION "Low watermark for storm control of this instance. If the rate drops below this value after having risen above the high watermark, a single notification will be generated." DEFVAL { 200 } ::= { bsStormControlEntry 3 } bsStormControlHighWatermark OBJECT-TYPE SYNTAX Unsigned32 (10..100000000) UNITS "packets per second" MAX-ACCESS read-write STATUS current DESCRIPTION "High watermark for storm control of this instance. If the rate rises above this value, notifications will be generated at the rate give by the bsStormControlTrapInterval object." DEFVAL { 500 } ::= { bsStormControlEntry 4 } bsStormControlPollInterval OBJECT-TYPE SYNTAX TimeInterval (500..30000) MAX-ACCESS read-write STATUS current DESCRIPTION "The polling interval for checking the packet rate for storm control of this instance." DEFVAL { 3000 } ::= { bsStormControlEntry 5 } bsStormControlTrapInterval OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The rate for sending storm control notifications, measured in a number of polling intervals." DEFVAL { 5 } ::= { bsStormControlEntry 6 } bsStormControlActionType OBJECT-TYPE SYNTAX INTEGER { none(1), drop(2), shutdown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Storm control action type for this instance." ::= { bsStormControlEntry 7 } -- -- Storm control interface table configuration -- bsStormControlIfTable OBJECT-TYPE SYNTAX SEQUENCE OF BsStormControlIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is used to control storm control settings per-interface." ::= { bsStormControlObjects 3 } bsStormControlIfEntry OBJECT-TYPE SYNTAX BsStormControlIfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing objects for controlling storm control settings for an interface." INDEX { bsStormControlTrafficType, bsStormControlIfIndex } ::= { bsStormControlIfTable 1 } BsStormControlIfEntry ::= SEQUENCE { bsStormControlIfIndex InterfaceIndex, bsStormControlIfEnabled TruthValue, bsStormControlIfLowWatermark Unsigned32, bsStormControlIfHighWatermark Unsigned32, bsStormControlIfPollInterval TimeInterval, bsStormControlIfTrapInterval Integer32, bsStormControlIfActionType INTEGER } bsStormControlIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex value of the interface." ::= { bsStormControlIfEntry 1 } bsStormControlIfEnabled OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether storm control is enabled for this instance." ::= { bsStormControlIfEntry 2 } bsStormControlIfLowWatermark OBJECT-TYPE SYNTAX Unsigned32 (10..100000000) UNITS "packets per second" MAX-ACCESS read-write STATUS current DESCRIPTION "Low watermark for storm control of this instance. If the rate drops below this value after having risen above the high watermark, a single notification will be generated." DEFVAL { 200 } ::= { bsStormControlIfEntry 3 } bsStormControlIfHighWatermark OBJECT-TYPE SYNTAX Unsigned32 (10..100000000) UNITS "packets per second" MAX-ACCESS read-write STATUS current DESCRIPTION "High watermark for storm control of this instance. If the rate rises above this value, notifications will be generated at the rate give by the bsStormControlTrapInterval object." DEFVAL { 500 } ::= { bsStormControlIfEntry 4 } bsStormControlIfPollInterval OBJECT-TYPE SYNTAX TimeInterval (500..30000) MAX-ACCESS read-write STATUS current DESCRIPTION "The polling interval for checking the packet rate for storm control of this instance." DEFVAL { 3000 } ::= { bsStormControlIfEntry 5 } bsStormControlIfTrapInterval OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "The rate for sending storm control notifications." DEFVAL { 5 } ::= { bsStormControlIfEntry 6 } bsStormControlIfActionType OBJECT-TYPE SYNTAX INTEGER { none(1), drop(2), shutdown(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Storm control action type for this instance." ::= { bsStormControlIfEntry 7 } -- -- Notifications -- bsStormControlBelowLowWatermark NOTIFICATION-TYPE OBJECTS { bsStormControlTrafficType, ifIndex, bsStormControlPollValue, bsStormControlLowWatermark } STATUS current DESCRIPTION "This notification is generated when the storm control packet type rate falls below the low watermark after having risen above the high watermark. It is generated only once when this occurs." ::= { bsStormControlNotifications 1 } bsStormControlAboveHighWatermark NOTIFICATION-TYPE OBJECTS { bsStormControlTrafficType, ifIndex, bsStormControlPollValue, bsStormControlHighWatermark } STATUS current DESCRIPTION "This notification is generated periodically as long as the storm control packet type rate remains above the high watermark." ::= { bsStormControlNotifications 2 } END