-- -- ASN.1 MIB Definitions -- Output Date: Tue Jul 12 15:01:04 2016 -- IPE-DOT3OAM-MIB DEFINITIONS ::= BEGIN ----------------------------------------------- -- IMPORTS Definitions ----------------------------------------------- IMPORTS InterfaceIndex, InterfaceIndexOrZero FROM IF-MIB Counter32, enterprises, Integer32, IpAddress, NOTIFICATION-TYPE, OBJECT-TYPE, Opaque, Unsigned32 FROM SNMPv2-SMI DateAndTime, MacAddress, TEXTUAL-CONVENTION FROM SNMPv2-TC; ----------------------------------------------- -- Textual Convention Definitions ----------------------------------------------- EnableDisableValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enable/Disable Type" SYNTAX INTEGER { invalid(0), disable(1), enable(2) } SeverityValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Severity (CCITT Rec. X.733)" SYNTAX INTEGER { cleared(1), indetermine(2), critical(3), major(4), minor(5), warning(6) } ----------------------------------------------- -- Begin User MIB Object Definitions ----------------------------------------------- nec OBJECT IDENTIFIER ::= { enterprises 119 } nec-mib OBJECT IDENTIFIER ::= { nec 2 } necProductDepend OBJECT IDENTIFIER ::= { nec-mib 3 } radioEquipment OBJECT IDENTIFIER ::= { necProductDepend 69 } pasoNeoIpe-common OBJECT IDENTIFIER ::= { radioEquipment 501 } ----------------------------------------------- -- IPE COMMON Group Definitions ----------------------------------------------- alarmStatusGroup OBJECT IDENTIFIER ::= { pasoNeoIpe-common 3 } provisioningGroup OBJECT IDENTIFIER ::= { pasoNeoIpe-common 5 } maintenanceGroup OBJECT IDENTIFIER ::= { pasoNeoIpe-common 6 } ----------------------------------------------- -- alarmStatusGroup Definitions ----------------------------------------------- asDot3OamGroup OBJECT IDENTIFIER ::= { alarmStatusGroup 46 } asDot3OamPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDot3OamPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains status of the OAM capabilities of the interface." ::= { asDot3OamGroup 1 } asDot3OamPortEntry OBJECT-TYPE SYNTAX AsDot3OamPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries in the table are created automatically." INDEX { asDot3OamPortIfIndex } ::= { asDot3OamPortTable 1 } AsDot3OamPortEntry ::= SEQUENCE { asDot3OamPortIfIndex InterfaceIndex, asDot3OamPortNEAddress IpAddress, asDot3OamPortOperStatus INTEGER, asDot3OamPortMaxOamPduSize Unsigned32, asDot3OamPortConfigRevision Unsigned32, asDot3OamPortFunctionsSupported BITS } asDot3OamPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { asDot3OamPortEntry 1 } asDot3OamPortNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { asDot3OamPortEntry 2 } asDot3OamPortOperStatus OBJECT-TYPE SYNTAX INTEGER { invalid(0), disabled(1), linkFault(2), passiveWait(3), activeSendLocal(4), sendLocalAndRemote(5), sendLocalAndRemoteOK(6), oamPeeringLocallyRejected(7), oamPeeringRemotelyRejected(8), operational(9), nonOperHalfDuplex(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value is always disabled(1) if OAM is disabled on the interface via the provDot3OamPortEnabled. If the link has detected a fault and is transmitting OAMPDUs with a link fault indication or the interface is not operational, the value is linkFault(2). The passiveWait(3) state is returned only by OAM entities in passive mode and reflects the state in which the OAM entity is waiting to see if the peer device is OA capable. The activeSendLocal(4) value is used by active mode trying to discover whether the peer has OAM capability but has not yet made that determination. The state sendLocalAndRemote(5) reflects that the local OA entity has discovered the peer but has not yet accepted or rejected the configuration of the peer. The local device can, for whatever reason, decide that the peer device is unacceptable and decline OAM peering. If the local OAM entity rejects the peer OAM entity, the state becomes oamPeeringLocallyRejected(7). If the OAM peering is allowed by the local device, the state moves to sendLocalAndRemoteOk(6). If the remote OAM entity rejects the peering, the state becomes oamPeeringRemotelyRejected(8). When the local OAM entity learns that both it and the remote OAM entity have accepted the peering, the state moves to operational(9). Since Ethernet OAM functions are not designed to work completely over half-duplex interfaces, the value nonOperHalfDuplex(10) is returned whenever Ethernet OAM is enabled, but the interface is in half-duplex operation." ::= { asDot3OamPortEntry 3 } asDot3OamPortMaxOamPduSize OBJECT-TYPE SYNTAX Unsigned32 (64..1518) UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The largest OAMPDU that the OAM entity supports. OA entities exchange maximum OAMPDU sizes and negotiate to use the smaller of the two maximum OAMPDU sizes between the peers." ::= { asDot3OamPortEntry 4 } asDot3OamPortConfigRevision OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The configuration revision of the OAM entity as reflected in the latest OAMPDU sent by the OAM entity. The config revision is used by OAM entities to indicate that configuration changes have occurred, which might require the peer OAM entity to re-evaluate whether OAM peering is allowed." ::= { asDot3OamPortEntry 5 } asDot3OamPortFunctionsSupported OBJECT-TYPE SYNTAX BITS { unidirectionalSupport(0), loopbackSupport(1), eventSupport(2), variableSupport(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM functions supported on this interface. OAM consists of separate functional sets beyond the basic discovery process that is always required. These functional groups can be supported independently by any implementation. These values are communicated to the peer via the local configuration field of Information OAMPDUs. Setting unidirectionalSupport(0) indicates that the OA entity supports the transmission of OAMPDUs on links that are operating in unidirectional mode. Setting loopbackSupport(1) indicates that the OAM entity can initiate and respond to loopback commands. Setting eventSupport(2) indicates that the OAM entity can send and receive Event Notification OAMPDUs. Setting variableSupport(3) indicates that the OAM entity can send and receive Variable Request and Response OAMPDUs." ::= { asDot3OamPortEntry 6 } asDot3OamPeerTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDot3OamPeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about the OAM peer for a particular interface. OAM entities communicates with a single OAM peer entity on Ethernet links." ::= { asDot3OamGroup 2 } asDot3OamPeerEntry OBJECT-TYPE SYNTAX AsDot3OamPeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table containing information on the peer entity for a single interface. Note that there is at most on OAM peer for each interface. Peer information is not reliable when asDot3OamPortStatus is disabled(1), linkFault(2), passiveWait(3), activeSendLocal(4), or nonOperHalfDuplex(10)." INDEX { asDot3OamPeerIfIndex } ::= { asDot3OamPeerTable 1 } AsDot3OamPeerEntry ::= SEQUENCE { asDot3OamPeerIfIndex InterfaceIndex, asDot3OamPeerNEAddress IpAddress, asDot3OamPeerMacAddress MacAddress, asDot3OamPeerVendorOui OCTET STRING, asDot3OamPeerVendorInfo Unsigned32, asDot3OamPeerMode INTEGER, asDot3OamPeerMaxOamPduSize Unsigned32, asDot3OamPeerConfigRevision Unsigned32, asDot3OamPeerFunctionsSupported BITS } asDot3OamPeerIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { asDot3OamPeerEntry 1 } asDot3OamPeerNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { asDot3OamPeerEntry 2 } asDot3OamPeerMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The MAC address of the peer OAM entity. The MAC address is derived from the most recently received OAMPDU." ::= { asDot3OamPeerEntry 3 } asDot3OamPeerVendorOui OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "The OUI of the OAM peer as reflected in the latest Information OAMPDU received with a Local Information TLV. The OUI can be used to identify the vendor of the remote OA entity. This value is initialized to three octets of zero before any Local Information TLV is received." ::= { asDot3OamPeerEntry 4 } asDot3OamPeerVendorInfo OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The Vendor Info of the OAM peer as reflected in the latest Information OAMPDU received with a Local Information TLV. The semantics of the Vendor Information field is proprietary and specific to the vendor. This value is initialized to zero before any Local Information TLV is received." ::= { asDot3OamPeerEntry 5 } asDot3OamPeerMode OBJECT-TYPE SYNTAX INTEGER { invalid(0), passive(1), active(2), unknown(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The mode of the OAM peer as reflected in the latest Information OAMPDU received with a Local Information TLV. The mode of the peer can be determined from the Configuration field in the Local Information TLV of the last Information OAMPDU received from the peer. The value is unknown(3) whenever no Local Information TLV has been received. The values of active(2) and passive(1) are returned when a Local Information TLV has been received indicating that the peer is in active or passive mode, respectively." ::= { asDot3OamPeerEntry 6 } asDot3OamPeerMaxOamPduSize OBJECT-TYPE SYNTAX Unsigned32 (0|64..1518) UNITS "octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum size of OAMPDU supported by the peer as reflected in the latest Information OAMPDU received with a Local Information TLV. Ethernet OAM on this interface must not use OAMPDUs that exceed this size. The maximum OAMPDU size can be determined from the PDU Configuration field of the Local Information TLV of the last Information OAMPDU received from the peer. A value of zero is returned if no Local Information TLV has been received. Otherwise, the value of the OAM peer's maximum OAMPDU size is returned in this value." ::= { asDot3OamPeerEntry 7 } asDot3OamPeerConfigRevision OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The configuration revision of the OAM peer as reflected in the latest OAMPDU. This attribute is changed by the peer whenever it has a local configuration change for Ethernet OA on this interface. The configuration revision can be determined from the Revision field of the Local Information TLV of the most recently received Information OAMPDU with a Local Information TLV. A value of zero is returned if no Local Information TLV has been received." ::= { asDot3OamPeerEntry 8 } asDot3OamPeerFunctionsSupported OBJECT-TYPE SYNTAX BITS { unidirectionalSupport(0), loopbackSupport(1), eventSupport(2), variableSupport(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The OAM functions supported on the interface. OAM consists of separate functionality sets above the basic discovery process. This value indicates the capabilities of the peer OAM entity with respect to these functions. This value is initialized so all bits are clear. If unidirectionalSupport(0) is set, the the peer OAM entity supports sending OAM frames on the interfaces when the receive path is known to be inoperable. If loopbackSupport(1) is set, then the peer OAM entity can send and receive OAM loopback commands. If eventSupport(2) is set, then the peer OAM entity can send and receive event OAMPDUs to signal various error conditions. If variableSupport(3) is set, then the peer OAM entity can send and receive variable requests to monitor the attribute value. The capabilities of the OAM peer can be determined from the configuration field of the Local Information TLV of the most recently received Information OAMPDU with a Local Information TLV. All zeros are returned if no Local Information TLV has yet been received." ::= { asDot3OamPeerEntry 9 } asDot3OamPortStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDot3OamPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains statistics for the OAM function on a particular interface. There is an entry in the table for every asDot3OamPortTable." ::= { asDot3OamGroup 3 } asDot3OamPortStatsEntry OBJECT-TYPE SYNTAX AsDot3OamPortStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table containing statistics information on the Ethernet OAM function for a single interface. Entries are automatically created for every entry in the asDot3OamPortTable. Counters are maintained across transitions in asDot3OamPortStatus." INDEX { asDot3OamPortStatsIfIndex } ::= { asDot3OamPortStatsTable 1 } AsDot3OamPortStatsEntry ::= SEQUENCE { asDot3OamPortStatsIfIndex InterfaceIndex, asDot3OamPortStatsNEAddress IpAddress, asDot3OamInformationTx Counter32, asDot3OamInformationRx Counter32, asDot3OamUniqueEventNotifTx Counter32, asDot3OamUniqueEventNotifRx Counter32, asDot3OamDuplicateEventNotifTx Counter32, asDot3OamDuplicateEventNotifRx Counter32, asDot3OamLoopbackControlTx Counter32, asDot3OamLoopbackControlRx Counter32, asDot3OamVariableRequestTx Counter32, asDot3OamVariableRequestRx Counter32, asDot3OamVariableResponseTx Counter32, asDot3OamVariableResponseRx Counter32, asDot3OamOrgSpecificTx Counter32, asDot3OamOrgSpecificRx Counter32, asDot3OamUnsupportedCodesTx Counter32, asDot3OamUnsupportedCodesRx Counter32, asDot3OamFramesLostDueToOam Counter32 } asDot3OamPortStatsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { asDot3OamPortStatsEntry 1 } asDot3OamPortStatsNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { asDot3OamPortStatsEntry 2 } asDot3OamInformationTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Information OAMPDUs transmitted on the interface." ::= { asDot3OamPortStatsEntry 3 } asDot3OamInformationRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Information OAMPDUs received on the interface." ::= { asDot3OamPortStatsEntry 4 } asDot3OamUniqueEventNotifTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of unique Event OAMPDUs transmitted on the interface. Event Notifications may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. Duplicate Event Notification transmissions are counted by asDot3OamDuplicatedEventNotifTx. A unique Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is distinct from the previously transmitted Event Notification OAMPDU Sequence Number." ::= { asDot3OamPortStatsEntry 5 } asDot3OamUniqueEventNotifRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of unique Event OAMPDUs received on the interface. Event Notifications may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. Duplicate Event Notification receptions are counted by asDot3OamDuplicateEventNotifRx. A unique Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Nubmer field that is distinct from the previously received Event Notification OAMPDU Sequence Number." ::= { asDot3OamPortStatsEntry 6 } asDot3OamDuplicateEventNotifTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of duplicate Event OAMPDUs transmitted on the interface. Event Notification OAMPDUs may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. A duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is identical to the previously transmitted Event Notification OAMPDU Sequence Number." ::= { asDot3OamPortStatsEntry 7 } asDot3OamDuplicateEventNotifRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of duplicate Event OAMPDUs received on the interface. Event Notification OAMPDUs may be sent in duplicate to increase the probability of successfully being received, given the possibility that a frame may be lost in transit. A duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU with a Sequence Number field that is identical to the previously received Event Notification OAMPDU Sequence Number." ::= { asDot3OamPortStatsEntry 8 } asDot3OamLoopbackControlTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Loopback Control OAMPDUs transmitted on the interface." ::= { asDot3OamPortStatsEntry 9 } asDot3OamLoopbackControlRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Loopback Control OAMPDUs received on the interface." ::= { asDot3OamPortStatsEntry 10 } asDot3OamVariableRequestTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Request OAMPDUs transmitted on the interface." ::= { asDot3OamPortStatsEntry 11 } asDot3OamVariableRequestRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Request OAMPDUs received on the interface." ::= { asDot3OamPortStatsEntry 12 } asDot3OamVariableResponseTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Response OAMPDUs transmitted on the interface." ::= { asDot3OamPortStatsEntry 13 } asDot3OamVariableResponseRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Variable Response OAMPDUs received on the interface." ::= { asDot3OamPortStatsEntry 14 } asDot3OamOrgSpecificTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Organization Specific OAMPDUs transmitted on the interface." ::= { asDot3OamPortStatsEntry 15 } asDot3OamOrgSpecificRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of Organization Specific OAMPDUs received on the interface." ::= { asDot3OamPortStatsEntry 16 } asDot3OamUnsupportedCodesTx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of OAMPDUs transmitted on the interface with an unsupported op-code." ::= { asDot3OamPortStatsEntry 17 } asDot3OamUnsupportedCodesRx OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of OAMPDUs received on the interface with an unsupported op-code." ::= { asDot3OamPortStatsEntry 18 } asDot3OamFramesLostDueToOam OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "A count of the number of frames that were dropped by the OA multiplexer. Since the OAM multiplexer has multiple inputs and a single output, there may be cases where frames are dropped due to transmit resource contention. This counter is incremented whenever a fram is dropped by the OAM layer. Note that any Ethernet frame, not just OAMPDUs, may be dropped by the OAM layer. This can occur when an OAMPDU takes precedence over a 'normal' frame resulting in the 'normal' frame being dropped. When this counter is incremented, no other counters in ths MIB are incremented." ::= { asDot3OamPortStatsEntry 19 } asDot3OamPortAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF AsDot3OamPortAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains alarm & status information of the interface." ::= { asDot3OamGroup 4 } asDot3OamPortAlarmEntry OBJECT-TYPE SYNTAX AsDot3OamPortAlarmEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table containing alarm & status information on the Ethernet OAM function for a single interface. Entries are automatically created for enery entry in the asDot3OamPortTable." INDEX { asDot3OamPortAlarmIfIndex } ::= { asDot3OamPortAlarmTable 1 } AsDot3OamPortAlarmEntry ::= SEQUENCE { asDot3OamPortAlarmIfIndex InterfaceIndex, asDot3OamPortAlarmNEAddress IpAddress, asDot3OamPortLinkOamDown SeverityValue, asDot3OamPortLocalDyingGasp INTEGER, asDot3OamPortLocalCriticalEvent INTEGER, asDot3OamPortRemoteErroredSymbolEvent INTEGER, asDot3OamPortRemoteErroredFramePeriodEvent INTEGER, asDot3OamPortRemoteErroredFrameEvent INTEGER, asDot3OamPortRemoteErroredFrameSecondEvent INTEGER, asDot3OamPortRemoteLinkFault SeverityValue, asDot3OamPortRemoteDyingGasp SeverityValue, asDot3OamPortRemoteCriticalEvent SeverityValue } asDot3OamPortAlarmIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { asDot3OamPortAlarmEntry 1 } asDot3OamPortAlarmNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { asDot3OamPortAlarmEntry 2 } asDot3OamPortLinkOamDown OBJECT-TYPE SYNTAX SeverityValue MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm status of the OAM function status. When the Discovery State of the interface is not in SEND_ANY, the object becomes alarm state." ::= { asDot3OamPortAlarmEntry 3 } asDot3OamPortLocalDyingGasp OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), generated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Generating Dying Gasp OAMPDU status. If the OAM entity sends the DyingGasp OAMPDUs, the object will return the value 'generated'." ::= { asDot3OamPortAlarmEntry 4 } asDot3OamPortLocalCriticalEvent OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), generated(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Generating Critical Event OAMPDU status. If the OAM entity sends the CriticalEvent OAMPDUs, the object will return the value 'generated'." ::= { asDot3OamPortAlarmEntry 5 } asDot3OamPortRemoteErroredSymbolEvent OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), received(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Errored Symbol Event OAMPDU status. If the OAM entity receives the ErroredSymbolEvent OAMPDUs from peer, the object will show the value 'received'." ::= { asDot3OamPortAlarmEntry 6 } asDot3OamPortRemoteErroredFramePeriodEvent OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), received(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Errored Frame Period Event OAMPDU status. If the OAM entity receives the ErroredFramePeriodEvent OAMPDUs from peer, the object will show the value 'received'." ::= { asDot3OamPortAlarmEntry 7 } asDot3OamPortRemoteErroredFrameEvent OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), received(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Errored Frame Event OAMPDU status. If the OAM entity receives the ErroredFrameEvent OAMPDUs from peer, the object will show the value 'received'." ::= { asDot3OamPortAlarmEntry 8 } asDot3OamPortRemoteErroredFrameSecondEvent OBJECT-TYPE SYNTAX INTEGER { invalid(0), normal(1), received(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Errored Frame Second Event OAMPDU status. If the OAM entity receives the ErroredFrameSecondEvent OAMPDUs from peer, the object will show the value 'received'." ::= { asDot3OamPortAlarmEntry 9 } asDot3OamPortRemoteLinkFault OBJECT-TYPE SYNTAX SeverityValue MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Link Fault OAMPDU. If the OAM entity receives the LinkFault OAMPDUs from peer, the object will report Link Fault Alarm of the interface." ::= { asDot3OamPortAlarmEntry 10 } asDot3OamPortRemoteDyingGasp OBJECT-TYPE SYNTAX SeverityValue MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving DyingGasp OAMPDU. If the OAM entity receives the DyingGasp OAMPDUs from peer, the object will report DyingGasp Alarm of the interface." ::= { asDot3OamPortAlarmEntry 11 } asDot3OamPortRemoteCriticalEvent OBJECT-TYPE SYNTAX SeverityValue MAX-ACCESS read-only STATUS current DESCRIPTION "Receiving Critial Event OAMPDU. If the OAM entity receives the CriticalEvent OAMPDUs from peer, the object will report CriticalEvent Alarm of the interface." ::= { asDot3OamPortAlarmEntry 12 } ----------------------------------------------- -- provisioningGroup Definitions ----------------------------------------------- provDot3OamGroup OBJECT IDENTIFIER ::= { provisioningGroup 46 } provDot3OamPortTable OBJECT-TYPE SYNTAX SEQUENCE OF ProvDot3OamPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains provisioning objects for the OAM function on a particular interface." ::= { provDot3OamGroup 1 } provDot3OamPortEntry OBJECT-TYPE SYNTAX ProvDot3OamPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the table that contains configuration on the Ethernet OAM function for sngle interface. Entries in the table are created automatically for each interface." INDEX { provDot3OamPortIfIndex } ::= { provDot3OamPortTable 1 } ProvDot3OamPortEntry ::= SEQUENCE { provDot3OamPortIfIndex InterfaceIndex, provDot3OamPortNEAddress IpAddress, provDot3OamPortEnabled EnableDisableValue, provDot3OamPortMode INTEGER, provDot3OamTxPduRepetitionTimes Integer32, provDot3OamLocalLinkLostTimer Integer32, provDot3OamTxPduCounts Integer32, provDot3OamLoopbackIgnoreRx INTEGER, provDot3OamLlfCriticalEvent EnableDisableValue } provDot3OamPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { provDot3OamPortEntry 1 } provDot3OamPortNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { provDot3OamPortEntry 2 } provDot3OamPortEnabled OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to provision the default administrative OAM mode for the interface. This object represents the desired state of OAM for this interface. This object always starts disabled state until explicit management action or configuration information retained by the system causes a transition to the enabled state. When enabled, Ethernet OAM will attempt to operate over this interface." DEFVAL { disable } ::= { provDot3OamPortEntry 3 } provDot3OamPortMode OBJECT-TYPE SYNTAX INTEGER { passive(1), active(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the mode of OAM operation for this interface. OAM on Ethernet interfaces may be in 'active' mode or 'passive' mode. These two modes differ in that active mode provides additional capabilities to initiate monitoring activities with the remote OAM peer entity, while passive mode generally waits for the peer to initiate OA actions with it. Changing this value results in incrementing the configuration revision field of locally generated OAMPDUs and potentially re-doing the OAM discovery process if the asDot3OamPortStatus was already operational(9)." DEFVAL { active } ::= { provDot3OamPortEntry 4 } provDot3OamTxPduRepetitionTimes OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the number of notification OAMPDUs when the critical event occurs." DEFVAL { 3 } ::= { provDot3OamPortEntry 5 } provDot3OamLocalLinkLostTimer OBJECT-TYPE SYNTAX Integer32 (1..10) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the detection time of losing the OAM Link state." DEFVAL { 5 } ::= { provDot3OamPortEntry 6 } provDot3OamTxPduCounts OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object configures the maximum transmission counts of slow protocol PDUs excluding DyingGasp and Critical Event PDUs." DEFVAL { 10 } ::= { provDot3OamPortEntry 7 } provDot3OamLoopbackIgnoreRx OBJECT-TYPE SYNTAX INTEGER { ignore(1), process(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "If ignore(1) is set, the OAM entity ignores Loopback Request OAMPDUs from peer OAM entity, and the OAM entity can only initiate loopback locally. It is necessary to change the value to process(2) to accept loopback request." DEFVAL { process } ::= { provDot3OamPortEntry 8 } provDot3OamLlfCriticalEvent OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable is set, the OAM entity sends OAMPDUs with Critical Event flag when the LLF control is notified." DEFVAL { enable } ::= { provDot3OamPortEntry 9 } provDot3OamEventTable OBJECT-TYPE SYNTAX SEQUENCE OF ProvDot3OamEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Ethernet OAM includes the ability to generate and receive Event Notification OAMPDUs to indicate various link problems. This table contains the mechanisms to enable Event Notifications. There is one entry in the table for every entry in asDot3OamPortTable. The values in the table are maintained across changes to asDot3OamPortStatus." ::= { provDot3OamGroup 3 } provDot3OamEventEntry OBJECT-TYPE SYNTAX ProvDot3OamEventEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries are automatically created and deleted from this table, and exists whenever the OAM entity supports Ethernet OA events. Event configuration controls when the local management entity sends Event Notification OAMPDUs to its OAM peer, and when certain event flags are set or cleared in OAMPDUs." INDEX { provDot3OamEventIfIndex } ::= { provDot3OamEventTable 1 } ProvDot3OamEventEntry ::= SEQUENCE { provDot3OamEventIfIndex InterfaceIndex, provDot3OamEventNEAddress IpAddress, provDot3OamErrSymPeriodEvNotifEnable EnableDisableValue, provDot3OamErrFramePeriodEvNotifEnable EnableDisableValue, provDot3OamErrFrameEvNotifEnable EnableDisableValue, provDot3OamErrFrameSecsEvNotifEnable EnableDisableValue, provDot3OamDyingGaspEnable EnableDisableValue, provDot3OamCriticalEventEnable EnableDisableValue } provDot3OamEventIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { provDot3OamEventEntry 1 } provDot3OamEventNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { provDot3OamEventEntry 2 } provDot3OamErrSymPeriodEvNotifEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the OAM entity should send an Event Notification OAMPDU when an Errored Symbol Period Event occurs." DEFVAL { disable } ::= { provDot3OamEventEntry 3 } provDot3OamErrFramePeriodEvNotifEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the OAM entity should send an Event Notification OAMPDU when an Errored Frame Period Event occurs." DEFVAL { disable } ::= { provDot3OamEventEntry 4 } provDot3OamErrFrameEvNotifEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the OAM entity should send an Event Notification OAMPDU when an Errored Frame Event occurs." DEFVAL { disable } ::= { provDot3OamEventEntry 5 } provDot3OamErrFrameSecsEvNotifEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the local OAM entity should send an Event Notification OAMPDU when an Errored Frame Seconds Event occurs." DEFVAL { disable } ::= { provDot3OamEventEntry 6 } provDot3OamDyingGaspEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the local OAM entity should attempt to indicate a dying gasp via the OAMPDU flags to its peer OAM entity when a dying gasp event occurs." DEFVAL { enable } ::= { provDot3OamEventEntry 7 } provDot3OamCriticalEventEnable OBJECT-TYPE SYNTAX EnableDisableValue MAX-ACCESS read-write STATUS current DESCRIPTION "If enable, the local OAM entity should attempt to indicate a critical event via the OAMPDU flags to its peer OAM entity when a critical event occurs." DEFVAL { enable } ::= { provDot3OamEventEntry 8 } ----------------------------------------------- -- maintenanceGroup Definitions ----------------------------------------------- maintDot3OamGroup OBJECT IDENTIFIER ::= { maintenanceGroup 46 } maintDot3OamLoopbackTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintDot3OamLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the On-demand Loopback control objects for Ethernet OAM functions." ::= { maintDot3OamGroup 1 } maintDot3OamLoopbackEntry OBJECT-TYPE SYNTAX MaintDot3OamLoopbackEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The system can execute up to 5 loopback functions simultaneously, so 5 entries are automatically created when agent boots." INDEX { maintDot3OamLoopbackIndex } ::= { maintDot3OamLoopbackTable 1 } MaintDot3OamLoopbackEntry ::= SEQUENCE { maintDot3OamLoopbackIndex Integer32, maintDot3OamLoopbackNEAddress IpAddress, maintDot3OamLoopbackIfIndex InterfaceIndexOrZero, maintDot3OamLoopbackExecute INTEGER, maintDot3OamLoopbackFrames Unsigned32, maintDot3OamLoopbackPDULength Unsigned32, maintDot3OamLoopbackTxCounts Unsigned32, maintDot3OamLoopbackTimeout Unsigned32 } maintDot3OamLoopbackIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { maintDot3OamLoopbackEntry 1 } maintDot3OamLoopbackNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { maintDot3OamLoopbackEntry 2 } maintDot3OamLoopbackIfIndex OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-write STATUS current DESCRIPTION "Set Index of target interface. The default value of this object is '0', and the value is necessary for executing loopback function." ::= { maintDot3OamLoopbackEntry 3 } maintDot3OamLoopbackExecute OBJECT-TYPE SYNTAX INTEGER { start(1), stop(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The object is used to execute loopback function. Setting to 'execute' to start loopback testing." ::= { maintDot3OamLoopbackEntry 4 } maintDot3OamLoopbackFrames OBJECT-TYPE SYNTAX Unsigned32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The object is used to configure the number of transmit loopback frames." DEFVAL { 10 } ::= { maintDot3OamLoopbackEntry 5 } maintDot3OamLoopbackPDULength OBJECT-TYPE SYNTAX Unsigned32 (64..1518) MAX-ACCESS read-write STATUS current DESCRIPTION "The length of Loopback OAMPDU." DEFVAL { 64 } ::= { maintDot3OamLoopbackEntry 6 } maintDot3OamLoopbackTxCounts OBJECT-TYPE SYNTAX Unsigned32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The object is used to configure the number of transmit frames per second." DEFVAL { 1 } ::= { maintDot3OamLoopbackEntry 7 } maintDot3OamLoopbackTimeout OBJECT-TYPE SYNTAX Unsigned32 (1..10) UNITS "seconds" MAX-ACCESS read-write STATUS current DESCRIPTION "The object is used to configure the time of detecting timeout of loopback testing." DEFVAL { 1 } ::= { maintDot3OamLoopbackEntry 8 } maintDot3OamLoopbackResultTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintDot3OamLoopbackResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the results of loopback testing. The results will be updated when the loopback testing is completed." ::= { maintDot3OamGroup 2 } maintDot3OamLoopbackResultEntry OBJECT-TYPE SYNTAX MaintDot3OamLoopbackResultEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entries are automatically created when the agent boots. And the index of the entry is identical to the 'maintDot3OamLoopbackIndex'." INDEX { maintDot3OamLoopbackResultIndex } ::= { maintDot3OamLoopbackResultTable 1 } MaintDot3OamLoopbackResultEntry ::= SEQUENCE { maintDot3OamLoopbackResultIndex Integer32, maintDot3OamLoopbackResultNEAddress IpAddress, maintDot3OamLoopbackResultTxFrames Unsigned32, maintDot3OamLoopbackResultTxFrameOctets Unsigned32, maintDot3OamLoopbackResultRxFrames Unsigned32, maintDot3OamLoopbackResultRxFrameOctets Unsigned32, maintDot3OamLoopbackResultRxErroredFrames Unsigned32, maintDot3OamLoopbackResultExecStatus INTEGER, maintDot3OamLoopbackResultLastExecute DateAndTime } maintDot3OamLoopbackResultIndex OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { maintDot3OamLoopbackResultEntry 1 } maintDot3OamLoopbackResultNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { maintDot3OamLoopbackResultEntry 2 } maintDot3OamLoopbackResultTxFrames OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted loopback OAMPDUs." ::= { maintDot3OamLoopbackResultEntry 3 } maintDot3OamLoopbackResultTxFrameOctets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total octets of transmitted loopback OAMPDUs." ::= { maintDot3OamLoopbackResultEntry 4 } maintDot3OamLoopbackResultRxFrames OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received loopback OAMPDUs." ::= { maintDot3OamLoopbackResultEntry 5 } maintDot3OamLoopbackResultRxFrameOctets OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total octets of received loopback OAMPDUs." ::= { maintDot3OamLoopbackResultEntry 6 } maintDot3OamLoopbackResultRxErroredFrames OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received errored OAMPDUs." ::= { maintDot3OamLoopbackResultEntry 7 } maintDot3OamLoopbackResultExecStatus OBJECT-TYPE SYNTAX INTEGER { noLoopback(1), failed(2), completed(3), executing(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of loopback test result. 'noLoopback' means no loopback test is executing. 'executing' represents the loopback test is in progress, and the new loopback request will be rejected. 'failed' means the previous loopback test failed. 'completed' means the previous loopback test completed successfully." ::= { maintDot3OamLoopbackResultEntry 8 } maintDot3OamLoopbackResultLastExecute OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time of executing loopback test." ::= { maintDot3OamLoopbackResultEntry 9 } maintDot3OamLoopbackPortTable OBJECT-TYPE SYNTAX SEQUENCE OF MaintDot3OamLoopbackPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains control objects for loopback which was triggered by peer node." ::= { maintDot3OamGroup 3 } maintDot3OamLoopbackPortEntry OBJECT-TYPE SYNTAX MaintDot3OamLoopbackPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { maintDot3OamLoopbackPortIfIndex } ::= { maintDot3OamLoopbackPortTable 1 } MaintDot3OamLoopbackPortEntry ::= SEQUENCE { maintDot3OamLoopbackPortIfIndex InterfaceIndex, maintDot3OamLoopbackPortNEAddress IpAddress, maintDot3OamLoopbackPortControl INTEGER, maintDot3OamLoopbackPortStatus INTEGER } maintDot3OamLoopbackPortIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of this table." ::= { maintDot3OamLoopbackPortEntry 1 } maintDot3OamLoopbackPortNEAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "reserved." ::= { maintDot3OamLoopbackPortEntry 2 } maintDot3OamLoopbackPortControl OBJECT-TYPE SYNTAX INTEGER { invalid(0), noOperation(1), initiateLoopback(2), terminateLoopback(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object controls the loopback function. Writing the value 'initiateLoopback' causes the local OAM entity to start the loopback process with its peer. This value can only be written when the maintDot3OamLoopbackPortStatus is 'noLoopback'. Writing the value 'initiateLoopback' in any other state has no effect. When maintDot3OamLoopbackPortStatus is in 'remoteLoopback' state, writing 'terminateLoopback' causes the local OAM entity to initiate the termination of the loopback state. Writing 'terminateLoopack' in any other state has no effect. Note. When getting this object, the agent always returns 'noOperation'. The loopback status can be obtained from maintDot3OamLoopbackPortStatus." ::= { maintDot3OamLoopbackPortEntry 3 } maintDot3OamLoopbackPortStatus OBJECT-TYPE SYNTAX INTEGER { invalid(0), noLoopback(1), remoteLoopback(2), localLoopback(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The loopback status of the local OAM entity. This object returns the loopback point. This means that the value 'remoteLoopback' represents the local OAM entity is initiator of loopback and the loopback point is on the peer (remote) node. On the other hand, the value 'localLoopback' means the loopback point is on the local node." ::= { maintDot3OamLoopbackPortEntry 4 } ----------------------------------------------- -- End User MIB Object Definitions ----------------------------------------------- END