-- *************************************************************** -- INFINERA-ENTITY-PEM-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-ENTITY-PEM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC entLPPhysicalIndex FROM ENTITY-MIB equipment FROM INFINERA-REG-MIB InfnEqptType,FloatTenths FROM INFINERA-TC-MIB; pemMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "INFINERA" CONTACT-INFO "Infinera 169 Java Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION "This MIB is modeling for PEM equipment table." ::= { equipment 15 } pemConformance OBJECT IDENTIFIER ::= { pemMIB 3 } pemCompliances OBJECT IDENTIFIER ::= { pemConformance 1 } pemGroups OBJECT IDENTIFIER ::= { pemConformance 2 } pemTable OBJECT-TYPE SYNTAX SEQUENCE OF PemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all PEM modules that are currently present in a network element. " ::= { pemMIB 1 } pemEntry OBJECT-TYPE SYNTAX PemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the PEM table. Each row in the table is identified with a unique entPhysicalIndexID. " INDEX { entLPPhysicalIndex } ::= { pemTable 1 } PemEntry ::= SEQUENCE { pemMoId DisplayString, pemProvEqptType InfnEqptType, provRatingAmps Unsigned32, installedRatingAmps Unsigned32, underVoltageThreshold FloatTenths, overVoltageThreshold FloatTenths, transientVoltageThreshold FloatTenths, inputVoltage Integer32 } pemMoId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the primary Key of the objects e.g 1-IOSHELF-PEMA, 1-IOSHELF-PEMB etc." ::= { pemEntry 1 } pemProvEqptType OBJECT-TYPE SYNTAX InfnEqptType MAX-ACCESS read-only STATUS current DESCRIPTION "The configured PEM type." ::= { pemEntry 2 } provRatingAmps OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Provisioned Rating AMPs." ::= { pemEntry 3 } installedRatingAmps OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Installed rating Amps." ::= { pemEntry 4 } underVoltageThreshold OBJECT-TYPE SYNTAX FloatTenths MAX-ACCESS read-only STATUS current DESCRIPTION "voltage under minimum threshold" ::= { pemEntry 5 } overVoltageThreshold OBJECT-TYPE SYNTAX FloatTenths MAX-ACCESS read-only STATUS current DESCRIPTION "high voltage threshold" ::= { pemEntry 6 } transientVoltageThreshold OBJECT-TYPE SYNTAX FloatTenths MAX-ACCESS read-only STATUS current DESCRIPTION "Transient voltage threshold value" ::= { pemEntry 7 } inputVoltage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { pemEntry 8 } pemCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "" MODULE MANDATORY-GROUPS { pemGroup } ::= { pemCompliances 1 } pemGroup OBJECT-GROUP OBJECTS { pemMoId, pemProvEqptType, provRatingAmps, installedRatingAmps, underVoltageThreshold, overVoltageThreshold, transientVoltageThreshold, inputVoltage } STATUS current DESCRIPTION "" ::= { pemGroups 1 } END