-- *************************************************************** -- INFINERA-ENTITY-GAM-MIB -- -- October 2008, Sharfuddin Syed / Narendra Gupta -- -- -- Copyright (c) 2008-2012 by Infinera Inc. -- All rights reserved. -- **************************************************************** INFINERA-ENTITY-GAM-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF RowStatus, DisplayString FROM SNMPv2-TC entLPPhysicalIndex FROM ENTITY-MIB equipment FROM INFINERA-REG-MIB InfnEqptType FROM INFINERA-TC-MIB; gamMIB MODULE-IDENTITY LAST-UPDATED "200810200000Z" ORGANIZATION "INFINERA" CONTACT-INFO "Infinera 169 Java Drive Sunnyvale, CA - 94089 Contact : Technical Support Email : support@infinera.com Phone : 1-877-INF-5288" DESCRIPTION "This MIB is modeling for GAM equipment table." ::= { equipment 8 } gamConformance OBJECT IDENTIFIER ::= { gamMIB 3 } gamCompliances OBJECT IDENTIFIER ::= { gamConformance 1 } gamGroups OBJECT IDENTIFIER ::= { gamConformance 2 } gamTable OBJECT-TYPE SYNTAX SEQUENCE OF GamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains all GAM modules that are currently present in a network element. " ::= { gamMIB 1 } gamEntry OBJECT-TYPE SYNTAX GamEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the GAM table. Each row in the table is identified with a unique entPhysicalIndexID. " INDEX { entLPPhysicalIndex } ::= { gamTable 1 } GamEntry ::= SEQUENCE { gamMoId DisplayString, gamProvEqptType InfnEqptType, gamRowStatus RowStatus, gamOperatingMode INTEGER, gamInstOperatingMode INTEGER } gamMoId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This is the primary Key of the objects e.g 1-A-3-1" ::= { gamEntry 1 } gamProvEqptType OBJECT-TYPE SYNTAX InfnEqptType MAX-ACCESS read-create STATUS current DESCRIPTION "The configured GAM type." ::= { gamEntry 2 } gamRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The row status of this GAM entry. Because rows in this table are indexed by entPhysicalIndex, to create a new row one must choose a value of entPhysicalIndex that is not already in use. A side-effect of the creation of a row in this table is the creation of a corresponding row in the eqptTable and the entPhysicalTable. The status may not be set to active if the gamMoId and gamProvEqptType are not set to valid values. This row may only be deleted if it was a pre-provisioned row and the hardware is not present. If this row is deleted, the associated row in the Eqpt Table and entPhysicalTable will be deleted by the agent." ::= { gamEntry 3 } gamOperatingMode OBJECT-TYPE SYNTAX INTEGER { none(1), gam(2), aseSource(3), aseGain(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "" ::= { gamEntry 4 } gamInstOperatingMode OBJECT-TYPE SYNTAX INTEGER { none(1), gam(2), aseSource(3), aseGain(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { gamEntry 5 } gamCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "" MODULE MANDATORY-GROUPS { gamGroup } ::= { gamCompliances 1 } gamGroup OBJECT-GROUP OBJECTS { gamMoId, gamProvEqptType, gamRowStatus, gamOperatingMode, gamInstOperatingMode } STATUS current DESCRIPTION "" ::= { gamGroups 1 } END