-- *------------------------------------------------------------------ -- * QTECH-SYNC-STATS-MIB.mib -- * Qtech Sync Statistics MIB. -- * -- * May 2009, yingde tan -- * -- * Copyright (c) 2009 by Qtech Networks Co.,Ltd. -- * All rights reserved. -- * -- *------------------------------------------------------------------ QTECH-SYNC-STATS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32 FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF qtechMgmt FROM QTECH-SMI InterfaceIndex FROM IF-MIB; qtechSyncStatsMIB MODULE-IDENTITY LAST-UPDATED "200905201456Z" ORGANIZATION "Qtech Networks Co.,Ltd." CONTACT-INFO " Tel: 4008-111-000 E-mail: service@qtech.com.cn" DESCRIPTION "Qtech Sync Statistics MIB. Acronyms The following acronyms are used in this document: CRC: Cyclic Redundancy Check HDLC: High-level Data Link Control MIB: Management Information Base MTU: Maximum Transmission Unit " REVISION "200905201456Z" DESCRIPTION "Added module compliance." ::= { qtechMgmt 51 } -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ -- MIB Objects -- +++++++++++++++++++++++++++++++++++++++++++++++++++++++ qtechSyncStatsMibObjects OBJECT IDENTIFIER ::= { qtechSyncStatsMIB 1 } qtechStatsSyncGlobal OBJECT IDENTIFIER ::= { qtechSyncStatsMibObjects 1 } qtechSyncStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechSyncStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The SYNC interface statistics MIB." ::= { qtechSyncStatsMibObjects 2 } qtechSyncStatsEntry OBJECT-TYPE SYNTAX QtechSyncStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry the qtechSyncStatsTable." INDEX { qtechSyncStatsSlot, qtechSyncStatsConn, qtechSyncStatsChannel } ::= { qtechSyncStatsTable 1 } QtechSyncStatsEntry ::= SEQUENCE { qtechSyncStatsRowStatus RowStatus, qtechSyncStatsSlot Integer32, qtechSyncStatsConn Integer32, qtechSyncStatsChannel Integer32, qtechSyncStatsIfIndex InterfaceIndex, qtechSyncStatsPortState INTEGER, qtechSyncStatsRxFrames Counter32, qtechSyncStatsRxOctets Counter32, qtechSyncStatsRxReplenFails Counter32, qtechSyncStatsRxClockErrors Counter32, qtechSyncStatsRxDpllErrors Counter32, qtechSyncStatsRxFrameTooLongErrors Counter32, qtechSyncStatsRxFrameOctetAlignErrors Counter32, qtechSyncStatsRxAbortErrors Counter32, qtechSyncStatsRxCrcErrors Counter32, qtechSyncStatsRxRcvrOverrunErrors Counter32, qtechSyncStatsTxFrames Counter32, qtechSyncStatsTxOctets Counter32, qtechSyncStatsTxRingFullDropsErrors Counter32, qtechSyncStatsTxClockErrors Counter32, qtechSyncStatsTxFrameTooLongErrors Counter32, qtechSyncStatsTxUnderrunErrors Counter32 } qtechSyncStatsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "The status of this row." ::= { qtechSyncStatsEntry 1 } qtechSyncStatsSlot OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical slot for this Sync port. Part of the index." ::= { qtechSyncStatsEntry 2 } qtechSyncStatsConn OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The physical connector for this Sync port. Part of the index." ::= { qtechSyncStatsEntry 3 } qtechSyncStatsChannel OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The virtual channel for this Sync port. Part of the index." ::= { qtechSyncStatsEntry 4 } qtechSyncStatsIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The IfIndex of this SYNC slot/conn/channel. This is configured, but configuration is not available via SNMP." ::= { qtechSyncStatsEntry 5 } qtechSyncStatsPortState OBJECT-TYPE SYNTAX INTEGER { init(1), -- port is coming up running(2), -- port has finished initialization -- and is waiting to transition to -- data state up(3), -- ready to pass packets down(4) -- port is down, unable to pass -- packets } MAX-ACCESS read-only STATUS current DESCRIPTION "The current operational state of the interface. The init(1) state indicates the port is in the state of trying to come up. It will transition to running(2) once initialization is complete. up(3) indicates the interface is capable of passing packets. down(4) indicates the interface is no longer capable of passing packets." ::= { qtechSyncStatsEntry 6 } qtechSyncStatsRxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received on this HDLC interface." ::= { qtechSyncStatsEntry 7 } qtechSyncStatsRxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets received on this HDLC interface." ::= { qtechSyncStatsEntry 8 } qtechSyncStatsRxReplenFails OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of times receive buffers could not be allocated on this HDLC interface." ::= { qtechSyncStatsEntry 9 } qtechSyncStatsRxClockErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of clock errors on this HDLC interface." ::= { qtechSyncStatsEntry 10 } qtechSyncStatsRxDpllErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of DPLL errors received on this HDLC interface." ::= { qtechSyncStatsEntry 11 } qtechSyncStatsRxFrameTooLongErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received long frame errors received on this HDLC interface." ::= { qtechSyncStatsEntry 12 } qtechSyncStatsRxFrameOctetAlignErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received long frame errors received on this HDLC interface." ::= { qtechSyncStatsEntry 13 } qtechSyncStatsRxAbortErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received abort errors received on this HDLC interface." ::= { qtechSyncStatsEntry 14 } qtechSyncStatsRxCrcErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CRC errors received on this HDLC interface." ::= { qtechSyncStatsEntry 15 } qtechSyncStatsRxRcvrOverrunErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of received CRC errors received on this HDLC interface." ::= { qtechSyncStatsEntry 16 } qtechSyncStatsTxFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted frames on this HDLC interface." ::= { qtechSyncStatsEntry 17 } qtechSyncStatsTxOctets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitted frames on this HDLC interface." ::= { qtechSyncStatsEntry 18 } qtechSyncStatsTxRingFullDropsErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames dropped on this HDLC interface because the transmit ring was full." ::= { qtechSyncStatsEntry 19 } qtechSyncStatsTxClockErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmit clock errors on this HDLC interface." ::= { qtechSyncStatsEntry 20 } qtechSyncStatsTxFrameTooLongErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames dropped this HDLC interface because they were long than the interface's MTU." ::= { qtechSyncStatsEntry 21 } qtechSyncStatsTxUnderrunErrors OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of transmitter underruns on this HDLC interface." ::= { qtechSyncStatsEntry 22 } qtechSyncStatsMibConformance OBJECT IDENTIFIER ::= { qtechSyncStatsMIB 2 } qtechSyncStatsMibCompliances OBJECT IDENTIFIER ::= { qtechSyncStatsMibConformance 1 } qtechSyncStatsMibGroups OBJECT IDENTIFIER ::= { qtechSyncStatsMibConformance 2 } qtechSyncStatsMibCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for agents which implement the Qtech Sync Statistics MIB." MODULE MANDATORY-GROUPS { qtechSyncStatsGroup } ::= { qtechSyncStatsMibCompliances 1 } qtechSyncStatsGroup OBJECT-GROUP OBJECTS { qtechSyncStatsRowStatus, qtechSyncStatsSlot, qtechSyncStatsConn, qtechSyncStatsChannel, qtechSyncStatsIfIndex, qtechSyncStatsPortState, qtechSyncStatsRxFrames, qtechSyncStatsRxOctets, qtechSyncStatsRxReplenFails, qtechSyncStatsRxClockErrors, qtechSyncStatsRxDpllErrors, qtechSyncStatsRxFrameTooLongErrors, qtechSyncStatsRxFrameOctetAlignErrors, qtechSyncStatsRxAbortErrors, qtechSyncStatsRxCrcErrors, qtechSyncStatsRxRcvrOverrunErrors, qtechSyncStatsTxFrames, qtechSyncStatsTxOctets, qtechSyncStatsTxRingFullDropsErrors, qtechSyncStatsTxClockErrors, qtechSyncStatsTxFrameTooLongErrors, qtechSyncStatsTxUnderrunErrors } STATUS current DESCRIPTION "The objects for SYNC configuration." ::= { qtechSyncStatsMibGroups 1 } END