ADTRAN-TA5K-FXS-FAC-MIB -- TITLE: The ADTRAN TA5000 FXS Factory MIB -- PRODUCT: TA5000 -- VERSION: 1.0 -- DATE: 11/09/11 -- AUTHOR: Peter Kerr -- STATUS: PRELIMINARY -- This MIB defines the object identifiers (OIDs) for use -- during factory calibration tests involving TA5000 FXS -- products. -- ***************************************************************************** DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC adTa5kFxsFac, adTa5kFxsFacID FROM ADTRAN-GENTA5K-MIB adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB ; -- ***************************************************************************** adTa5kFxsFacIdentity MODULE-IDENTITY LAST-UPDATED "201111090000Z" ORGANIZATION "Adtran, Inc." CONTACT-INFO "CND Tech Support Postal: ADTRAN, Inc. 901 Explorer Blvd. Huntsville, AL 35806 Tel: +1 800 726-8663 Fax: +1 256 963 6217 E-mail: support@adtran.com" DESCRIPTION "This MIB defines the object identifiers (OIDs) for use during factory calibration tests involving TA5000 FXS products." REVISION "201111090000Z" DESCRIPTION "Created" ::= { adTa5kFxsFacID 1 } --============================================================================== -- Limited THL test table --============================================================================== adTa5kFxsFacLimitedThlTable OBJECT-TYPE SYNTAX SEQUENCE OF AdTa5kFxsFacLimitedThlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Limited THL test is used during the factory calibration of the TA5000 CPOTS Module (1187160F1). It sends three tones port port towards the CPOTS module, which should be off-hook, and measures the resultant Echo Return Loss (ERL)." ::= { adTa5kFxsFac 1 } adTa5kFxsFacLimitedThlEntry OBJECT-TYPE SYNTAX AdTa5kFxsFacLimitedThlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "..." INDEX { adGenSlotInfoIndex } ::= { adTa5kFxsFacLimitedThlTable 1 } AdTa5kFxsFacLimitedThlEntry ::= SEQUENCE { adTa5kFxsFacLimitedThlStart INTEGER, adTa5kFxsFacLimitedThlStatus INTEGER, adTa5kFxsFacLimitedThlResults OCTET STRING } adTa5kFxsFacLimitedThlStart OBJECT-TYPE SYNTAX INTEGER { begin(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to start the test." ::= { adTa5kFxsFacLimitedThlEntry 1 } adTa5kFxsFacLimitedThlStatus OBJECT-TYPE SYNTAX INTEGER { na(1), complete(2), fault(3), running(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Use to monitor test progress: 1 = na Returned when test has never been run. 2 = complete Returned once test has completed successfully. 3 = fault Returned if test aborted due to a failure. 4 = running Returned while test is in progress." ::= { adTa5kFxsFacLimitedThlEntry 2 } adTa5kFxsFacLimitedThlResults OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Returns a vector of 32-bit unsigned integers (split into octets containing the measured ERL for each port of the card under test in mdB units. The first uint32 is always empty. The first port can be found in the second unint32." ::= { adTa5kFxsFacLimitedThlEntry 3 } END