-- ************************************************ -- $Id: Vct-Loopdetect-59.mib 8 2009-01-16 12:17:08Z Caosl $ -- -- Vct-Loopdetect-59.mib: Vct Loopdetect 59 MIB file -- -- Jan. 2009, 072195 -- -- Copyright(c) 2009 by ZTE Corporaton -- All rights reservered -- -- ************************************************ Vct-Loopdetect-59-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, experimental, Integer32, Unsigned32, Counter32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF enterprises FROM SNMPv2-SMI MacAddress,RowStatus FROM SNMPv2-TC mgmt, NetworkAddress, IpAddress, Counter, Gauge FROM RFC1155-SMI ifIndex FROM RFC1213-MIB; zte OBJECT IDENTIFIER ::= { enterprises 3902 } zxr10 OBJECT IDENTIFIER ::= { zte 3} zxr10switch OBJECT IDENTIFIER ::= { zxr10 102} switch59vct OBJECT IDENTIFIER ::= { zxr10switch 24 } switch59loopdetect OBJECT IDENTIFIER ::= { zxr10switch 25 } DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- SIZE (0..255) -- The mib about vct and loopdetect vctTable OBJECT-TYPE SYNTAX SEQUENCE OF VctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The vctTable contains the parameter of cable." ::= { switch59vct 1 } vctEntry OBJECT-TYPE SYNTAX VctEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The parameter list of cable." INDEX { vctIfindex } ::= { vctTable 1 } VctEntry ::= SEQUENCE { vctIfindex Integer32, vctSetIfindex INTEGER, cableStatus INTEGER, doubleCableStatus1-2 INTEGER, doubleCableStatus3-6 INTEGER, doubleCableStatus4-5 INTEGER, doubleCableStatus7-8 INTEGER, doubleCableLength1-2 INTEGER, doubleCableLength3-6 INTEGER, doubleCableLength4-5 INTEGER, doubleCableLength7-8 INTEGER } vctIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of port,it is same to ifindex." ::= { vctEntry 1 } vctSetIfindex OBJECT-TYPE SYNTAX INTEGER{enable(1),disable(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "The ifindex of port, which need to be checked." ::= { vctEntry 2 } cableStatus OBJECT-TYPE SYNTAX INTEGER{good(1),fault(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "The status of cable, either good or fault." ::= { vctEntry 3 } doubleCableStatus1-2 OBJECT-TYPE SYNTAX INTEGER{ good(0), open(1), short(2), broken(3), mismatch(4), fail(5), unknown(6), null(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of cable pair 1-2." ::= { vctEntry 4 } doubleCableStatus3-6 OBJECT-TYPE SYNTAX INTEGER{ good(0), open(1), short(2), broken(3), mismatch(4), fail(5), unknown(6), null(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of cable pair 3-6." ::= { vctEntry 5 } doubleCableStatus4-5 OBJECT-TYPE SYNTAX INTEGER{ good(0), open(1), short(2), broken(3), mismatch(4), fail(5), unknown(6), null(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of cable pair 4-5." ::= { vctEntry 6 } doubleCableStatus7-8 OBJECT-TYPE SYNTAX INTEGER{ good(0), open(1), short(2), broken(3), mismatch(4), fail(5), unknown(6), null(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of cable pair 7-8." ::= { vctEntry 7 } doubleCableLength1-2 OBJECT-TYPE SYNTAX INTEGER{ lessthan50(200), from50to80(201), from80to110(202), from110to140(203), morethan140(204), unknow(205), null(206) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of cable pair 1-2." ::= { vctEntry 8 } doubleCableLength3-6 OBJECT-TYPE SYNTAX INTEGER{ lessthan50(200), from50to80(201), from80to110(202), from110to140(203), morethan140(204), unknow(205), null(206) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of cable pair 3-6." ::= { vctEntry 9 } doubleCableLength4-5 OBJECT-TYPE SYNTAX INTEGER{ lessthan50(200), from50to80(201), from80to110(202), from110to140(203), morethan140(204), unknow(205), null(206) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of cable pair 4-5." ::= { vctEntry 10 } doubleCableLength7-8 OBJECT-TYPE SYNTAX INTEGER{ lessthan50(200), from50to80(201), from80to110(202), from110to140(203), morethan140(204), unknow(205), null(206) } MAX-ACCESS read-only STATUS current DESCRIPTION "The length of cable pair 7-8." ::= { vctEntry 11 } loopdetectReopenTime OBJECT-TYPE SYNTAX Integer32(1..16777216) MAX-ACCESS read-write STATUS current DESCRIPTION "The max time when the loopdetected port is " ::= { switch59loopdetect 1 } loopdetectTable OBJECT-TYPE SYNTAX SEQUENCE OF LoopdetectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The parameter which the loopdetectTable contains." ::= { switch59loopdetect 2 } loopdetectEntry OBJECT-TYPE SYNTAX LoopdetectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The parameter list shows the happened loopdetect." INDEX { loopdetectPortIfindex } ::= { loopdetectTable 1 } LoopdetectEntry ::= SEQUENCE { loopdetectPortIfindex Integer32, loopdetectPortOperStatus INTEGER, loopdetectPortControl INTEGER, loopdetectPortVid OCTET STRING, loopdetectPortFlag INTEGER, loopdetectPortProtectFlag INTEGER, loopdetectPortReopenTime Integer32, loopdetectVlan Integer32 } loopdetectPortIfindex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index of port, it is same to ifindex." ::= { loopdetectEntry 1 } loopdetectPortOperStatus OBJECT-TYPE SYNTAX INTEGER{up(1),down(0)} MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the port." ::= { loopdetectEntry 2 } loopdetectPortControl OBJECT-TYPE SYNTAX INTEGER{enable(1),disable(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "The loopdetect protocol enable/disable." ::= { loopdetectEntry 3 } loopdetectPortVid OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The vlan which the loopdetect port belong to." ::= { loopdetectEntry 4 } loopdetectPortFlag OBJECT-TYPE SYNTAX INTEGER{no(0),yes(1)} MAX-ACCESS read-only STATUS current DESCRIPTION "The result of loopdetect on the port." ::= { loopdetectEntry 5 } loopdetectPortProtectFlag OBJECT-TYPE SYNTAX INTEGER{enable(1),disable(0)} MAX-ACCESS read-write STATUS current DESCRIPTION "The loopdetect protect in the port is enable/disable." ::= { loopdetectEntry 6 } loopdetectPortReopenTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "How long the port will be opened " ::= { loopdetectEntry 7 } loopdetectVlan OBJECT-TYPE SYNTAX Integer32(1..4094) MAX-ACCESS read-only STATUS current DESCRIPTION "The vlan contains the port which happened loopdetect." ::= { loopdetectEntry 8 } END