WebGraph-OLD-Thermometer-NTC-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.32 ---------------------------------------------------------------- -- 15.07.2015 Changes for new Navigation (__JB__) ---------------------------------------------------------------- -- Revison: 1.31 ---------------------------------------------------------------- -- 15.07.2015 Changes for new Navigation (__JB__) ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 06.02.2012 WebIO -- New: wtWebioAn1GraphPtAlarmDeltaTemp ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 22.06.2010 Output with decimal point -- ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 09.05.2007 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 22.05.2006 Table entry names changed -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57605, WebGraph Thermometer -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57605, WebGraph Thermometer -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 02.06.2005 #57605, WebGraph Thermometer -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57605, WebGraph -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 27.09.2004 #57601/3/4, Webio Digital -- New: -- Entry AlarmHysteresis corrected ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioAn1GraphNtcInputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioAn1GraphNtc OBJECT IDENTIFIER ::= { wtWebio 18 } -- wtWebioAn1GraphNtc Tree wtWebioAn1GraphNtcTemp OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtc 1 } wtWebioAn1GraphNtcSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtc 2 } wtWebioAn1GraphNtcConfig OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtc 3 } -- wtWebioAn1GraphNtcConfig Tree wtWebioAn1GraphNtcDevice OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcConfig 1 } wtWebioAn1GraphNtcPorts OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcConfig 2 } wtWebioAn1GraphNtcManufact OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcConfig 3 } -- wtWebioAn1GraphNtcDevice Tree wtWebioAn1GraphNtcText OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 1 } wtWebioAn1GraphNtcTimeDate OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 2 } wtWebioAn1GraphNtcBasic OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 3 } wtWebioAn1GraphNtcDatalogger OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 4 } wtWebioAn1GraphNtcAlarm OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 5 } wtWebioAn1GraphNtcGraphics OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcDevice 6 } -- wtWebioAn1GraphNtcTimeDate Tree wtWebioAn1GraphNtcTimeZone OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcTimeDate 1 } wtWebioAn1GraphNtcTimeServer OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcTimeDate 2 } wtWebioAn1GraphNtcDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcTimeDate 3 } -- wtWebioAn1GraphNtcBasic Tree wtWebioAn1GraphNtcNetwork OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 1 } wtWebioAn1GraphNtcHTTP OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 2 } wtWebioAn1GraphNtcMail OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 3 } wtWebioAn1GraphNtcSNMP OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 4 } wtWebioAn1GraphNtcUDP OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 5 } wtWebioAn1GraphNtcSyslog OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 6 } wtWebioAn1GraphNtcFTP OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcBasic 7 } -- wtWebioAn1GraphNtcGraphics Tree wtWebioAn1GraphNtcGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcGraphics 1 } wtWebioAn1GraphNtcGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcGraphics 2 } wtWebioAn1GraphNtcGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn1GraphNtcGraphics 3 } -- wtWebioAn1GraphNtcTemp Group ------------------------ wtWebioAn1GraphNtcSensors OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Number of temperature sensors" ::= { wtWebioAn1GraphNtcTemp 1 } -- Interface Table wtWebioAn1GraphNtcSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebioAn1GraphNtcTemp 2 } wtWebioAn1GraphNtcSensorEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperature sensor numbers." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcSensorTable 1 } WtWebioAn1GraphNtcSensorEntry ::= SEQUENCE { wtWebioAn1GraphNtcSensorNo INTEGER } wtWebioAn1GraphNtcSensorNo OBJECT-TYPE SYNTAX INTEGER (1) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor number." ::= { wtWebioAn1GraphNtcSensorEntry 1 } -- wtWebioAn1GraphNtcTempValue Table wtWebioAn1GraphNtcTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn1GraphNtcTemp 3 } wtWebioAn1GraphNtcTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcTempValueTable 1 } WtWebioAn1GraphNtcTempValueEntry ::= SEQUENCE{ wtWebioAn1GraphNtcTempValue OCTET STRING } wtWebioAn1GraphNtcTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length." ::= { wtWebioAn1GraphNtcTempValueEntry 1 } -- wtWebioAn1GraphNtcBinaryTempValue Table wtWebioAn1GraphNtcBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary temperature values corresponding to the channel numbers." ::= { wtWebioAn1GraphNtcTemp 4 } wtWebioAn1GraphNtcBinaryTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary temperature values of the sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcBinaryTempValueTable 1 } WtWebioAn1GraphNtcBinaryTempValueEntry ::= SEQUENCE{ wtWebioAn1GraphNtcBinaryTempValue INTEGER } wtWebioAn1GraphNtcBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x7FFF indicates an invalid measured value." ::= { wtWebioAn1GraphNtcBinaryTempValueEntry 1 } -- wtWebioAn1GraphNtcTempValuePkt Table wtWebioAn1GraphNtcTempValuePktTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn1GraphNtcTemp 8 } wtWebioAn1GraphNtcTempValuePktEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcTempValuePktTable 1 } WtWebioAn1GraphNtcTempValuePktEntry ::= SEQUENCE{ wtWebioAn1GraphNtcTempValuePkt OCTET STRING } wtWebioAn1GraphNtcTempValuePkt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length, decimal point." ::= { wtWebioAn1GraphNtcTempValuePktEntry 1 } -- wtWebioAn1GraphNtcSessCntrl Group -------------------------------- wtWebioAn1GraphNtcSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioAn1GraphNtcSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioAn1GraphNtcSessCntrl 1 } wtWebioAn1GraphNtcSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcSessCntrl-NoSession(0), wtWebioAn1GraphNtcSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioAn1GraphNtcSessCntrl 2 } wtWebioAn1GraphNtcSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioAn1GraphNtcSessCntrl 3 } wtWebioAn1GraphNtcSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioAn1GraphNtcSessCntrl 4 } wtWebioAn1GraphNtcSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioAn1GraphNtcSessCntrl 5 } -- wtWebioAn1GraphNtcText Group ------------------------ wtWebioAn1GraphNtcDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioAn1GraphNtcText 1 } wtWebioAn1GraphNtcDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioAn1GraphNtcText 2 } wtWebioAn1GraphNtcDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioAn1GraphNtcText 3 } wtWebioAn1GraphNtcDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioAn1GraphNtcText 4 } -- wtWebioAn1GraphNtcTimeZone Group ---------------------------- wtWebioAn1GraphNtcTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 1 } wtWebioAn1GraphNtcTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 2 } wtWebioAn1GraphNtcTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioAn1GraphNtcTimeZone 3 } wtWebioAn1GraphNtcStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 4 } wtWebioAn1GraphNtcStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 5 } wtWebioAn1GraphNtcStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioAn1GraphNtcTimeZone 6 } wtWebioAn1GraphNtcStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStartMonth-January(1), wtWebioAn1GraphNtcStartMonth-February(2), wtWebioAn1GraphNtcStartMonth-March(3), wtWebioAn1GraphNtcStartMonth-April(4), wtWebioAn1GraphNtcStartMonth-May(5), wtWebioAn1GraphNtcStartMonth-June(6), wtWebioAn1GraphNtcStartMonth-July(7), wtWebioAn1GraphNtcStartMonth-August(8), wtWebioAn1GraphNtcStartMonth-September(9), wtWebioAn1GraphNtcStartMonth-October(10), wtWebioAn1GraphNtcStartMonth-November(11), wtWebioAn1GraphNtcStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioAn1GraphNtcTimeZone 7 } wtWebioAn1GraphNtcStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStartMode-first(1), wtWebioAn1GraphNtcStartMode-second(2), wtWebioAn1GraphNtcStartMode-third(3), wtWebioAn1GraphNtcStartMode-fourth(4), wtWebioAn1GraphNtcStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioAn1GraphNtcTimeZone 8 } wtWebioAn1GraphNtcStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStartWday-Sunday(1), wtWebioAn1GraphNtcStartWday-Monday(2), wtWebioAn1GraphNtcStartWday-Tuesday(3), wtWebioAn1GraphNtcStartWday-Thursday(4), wtWebioAn1GraphNtcStartWday-Wednesday(5), wtWebioAn1GraphNtcStartWday-Friday(6), wtWebioAn1GraphNtcStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioAn1GraphNtcTimeZone 9 } wtWebioAn1GraphNtcStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 10 } wtWebioAn1GraphNtcStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 11 } wtWebioAn1GraphNtcStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStopMonth-January(1), wtWebioAn1GraphNtcStopMonth-February(2), wtWebioAn1GraphNtcStopMonth-March(3), wtWebioAn1GraphNtcStopMonth-April(4), wtWebioAn1GraphNtcStopMonth-May(5), wtWebioAn1GraphNtcStopMonth-June(6), wtWebioAn1GraphNtcStopMonth-July(7), wtWebioAn1GraphNtcStopMonth-August(8), wtWebioAn1GraphNtcStopMonth-September(9), wtWebioAn1GraphNtcStopMonth-October(10), wtWebioAn1GraphNtcStopMonth-November(11), wtWebioAn1GraphNtcStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioAn1GraphNtcTimeZone 12 } wtWebioAn1GraphNtcStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStopMode-first(1), wtWebioAn1GraphNtcStopMode-second(2), wtWebioAn1GraphNtcStopMode-third(3), wtWebioAn1GraphNtcStopMode-fourth(4), wtWebioAn1GraphNtcStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioAn1GraphNtcTimeZone 13 } wtWebioAn1GraphNtcStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcStopWday-Sunday(1), wtWebioAn1GraphNtcStopWday-Monday(2), wtWebioAn1GraphNtcStopWday-Tuesday(3), wtWebioAn1GraphNtcStopWday-Thursday(4), wtWebioAn1GraphNtcStopWday-Wednesday(5), wtWebioAn1GraphNtcStopWday-Friday(6), wtWebioAn1GraphNtcStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioAn1GraphNtcTimeZone 14 } wtWebioAn1GraphNtcStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 15 } wtWebioAn1GraphNtcStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn1GraphNtcTimeZone 16 } -- wtWebioAn1GraphNtcTimeServer Group ---------------------------- wtWebioAn1GraphNtcTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioAn1GraphNtcTimeServer 1 } wtWebioAn1GraphNtcTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioAn1GraphNtcTimeServer 2 } wtWebioAn1GraphNtcTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioAn1GraphNtcTimeServer 3 } wtWebioAn1GraphNtcTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioAn1GraphNtcTimeServer 4 } -- wtWebioAn1GraphNtcDeviceClock Group ---------------------------- wtWebioAn1GraphNtcClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioAn1GraphNtcDeviceClock 1 } wtWebioAn1GraphNtcClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioAn1GraphNtcDeviceClock 2 } wtWebioAn1GraphNtcClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioAn1GraphNtcDeviceClock 3 } wtWebioAn1GraphNtcClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcClockMonth-January(1), wtWebioAn1GraphNtcClockMonth-February(2), wtWebioAn1GraphNtcClockMonth-March(3), wtWebioAn1GraphNtcClockMonth-April(4), wtWebioAn1GraphNtcClockMonth-May(5), wtWebioAn1GraphNtcClockMonth-June(6), wtWebioAn1GraphNtcClockMonth-July(7), wtWebioAn1GraphNtcClockMonth-August(8), wtWebioAn1GraphNtcClockMonth-September(9), wtWebioAn1GraphNtcClockMonth-October(10), wtWebioAn1GraphNtcClockMonth-November(11), wtWebioAn1GraphNtcClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioAn1GraphNtcDeviceClock 4 } wtWebioAn1GraphNtcClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioAn1GraphNtcDeviceClock 5 } -- wtWebioAn1GraphNtcNetwork Group ------------------------ wtWebioAn1GraphNtcIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioAn1GraphNtcNetwork 1 } wtWebioAn1GraphNtcSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioAn1GraphNtcNetwork 2 } wtWebioAn1GraphNtcGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioAn1GraphNtcNetwork 3 } wtWebioAn1GraphNtcDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioAn1GraphNtcNetwork 4 } wtWebioAn1GraphNtcDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioAn1GraphNtcNetwork 5 } wtWebioAn1GraphNtcAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebioAn1GraphNtcNetwork 6 } -- wtWebioAn1GraphNtcHTTP Group -------------------------------- wtWebioAn1GraphNtcStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebioAn1GraphNtcHTTP 1 } wtWebioAn1GraphNtcGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioAn1GraphNtcHTTP 2 } wtWebioAn1GraphNtcHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioAn1GraphNtcHTTP 3 } -- wtWebioAn1GraphNtcMail Group -------------------------------- wtWebioAn1GraphNtcMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioAn1GraphNtcMail 1 } wtWebioAn1GraphNtcMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioAn1GraphNtcMail 2 } wtWebioAn1GraphNtcMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioAn1GraphNtcMail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioAn1GraphNtcMail 4 } wtWebioAn1GraphNtcMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioAn1GraphNtcMail 5 } wtWebioAn1GraphNtcMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioAn1GraphNtcMail 6 } wtWebioAn1GraphNtcMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioAn1GraphNtcMail 7 } wtWebioAn1GraphNtcMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioAn1GraphNtcMail 8 } -- wtWebioAn1GraphNtcSNMP Group -------------------------------- wtWebioAn1GraphNtcSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioAn1GraphNtcSNMP 1 } wtWebioAn1GraphNtcSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioAn1GraphNtcSNMP 2 } wtWebioAn1GraphNtcSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioAn1GraphNtcSNMP 3 } wtWebioAn1GraphNtcSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebioAn1GraphNtcSNMP 4 } wtWebioAn1GraphNtcSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioAn1GraphNtcSNMP 5 } wtWebioAn1GraphNtcSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebioAn1GraphNtcSNMP 6 } -- wtWebioAn1GraphNtcUDP Group -------------------------------- wtWebioAn1GraphNtcUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioAn1GraphNtcUDP 1 } wtWebioAn1GraphNtcUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioAn1GraphNtcUDP 2 } -- wtWebioAn1GraphNtcSyslog Group -------------------------------- wtWebioAn1GraphNtcSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioAn1GraphNtcSyslog 1 } wtWebioAn1GraphNtcSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioAn1GraphNtcSyslog 2 } wtWebioAn1GraphNtcSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioAn1GraphNtcSyslog 3 } wtWebioAn1GraphNtcSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioAn1GraphNtcSyslog 4 } -- wtWebioAn1GraphNtcFTP Group -------------------------------- wtWebioAn1GraphNtcFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioAn1GraphNtcFTP 1 } wtWebioAn1GraphNtcFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioAn1GraphNtcFTP 2 } wtWebioAn1GraphNtcFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioAn1GraphNtcFTP 3 } wtWebioAn1GraphNtcFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioAn1GraphNtcFTP 4 } wtWebioAn1GraphNtcFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioAn1GraphNtcFTP 5 } wtWebioAn1GraphNtcFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioAn1GraphNtcFTP 6 } wtWebioAn1GraphNtcFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioAn1GraphNtcFTP 7 } -- wtWebioAn1GraphNtcDatalogger Group -------------------------------- wtWebioAn1GraphNtcLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcDatalogger-1Min(1), wtWebioAn1GraphNtcDatalogger-5Min(2), wtWebioAn1GraphNtcDatalogger-15Min(3), wtWebioAn1GraphNtcDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebioAn1GraphNtcDatalogger 1 } wtWebioAn1GraphNtcLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphNtcDatalogger 2 } wtWebioAn1GraphNtcDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphNtcDatalogger 3 } -- Graph Sensor Color Table wtWebioAn1GraphNtcSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn1GraphNtcDatalogger 4 } wtWebioAn1GraphNtcSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcSensorColorTable 1 } WtWebioAn1GraphNtcSensorColorEntry ::= SEQUENCE { wtWebioAn1GraphNtcSensorColor OCTET STRING } wtWebioAn1GraphNtcSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn1GraphNtcSensorColorEntry 1 } wtWebioAn1GraphNtcAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebioAn1GraphNtcDatalogger 5 } wtWebioAn1GraphNtcVerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcDatalogger 6 } wtWebioAn1GraphNtcVerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcDatalogger 7 } wtWebioAn1GraphNtcHorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebioAn1GraphNtcZoom-25min(1), wtWebioAn1GraphNtcZoom-75min(2), wtWebioAn1GraphNtcZoom-5hrs(3), wtWebioAn1GraphNtcZoom-30hrs(4), wtWebioAn1GraphNtcZoom-5days(5), wtWebioAn1GraphNtcZoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebioAn1GraphNtcDatalogger 8 } -- wtWebioAn1GraphNtcAlarm Group ---------------------------- wtWebioAn1GraphNtcAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioAn1GraphNtcAlarm 1 } -- Alarm Interface Table wtWebioAn1GraphNtcAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioAn1GraphNtcAlarm 2 } wtWebioAn1GraphNtcAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioAn1GraphNtcAlarmNo } ::= { wtWebioAn1GraphNtcAlarmIfTable 1 } WtWebioAn1GraphNtcAlarmIfEntry ::= SEQUENCE { wtWebioAn1GraphNtcAlarmNo INTEGER } wtWebioAn1GraphNtcAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebioAn1GraphNtcAlarmIfEntry 1 } -- Alarm Table wtWebioAn1GraphNtcAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioAn1GraphNtcAlarm 3 } wtWebioAn1GraphNtcAlarmEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioAn1GraphNtcAlarmNo } ::= { wtWebioAn1GraphNtcAlarmTable 1 } WtWebioAn1GraphNtcAlarmEntry ::= SEQUENCE { wtWebioAn1GraphNtcAlarmTrigger OCTET STRING, wtWebioAn1GraphNtcAlarmMin OCTET STRING, wtWebioAn1GraphNtcAlarmMax OCTET STRING, wtWebioAn1GraphNtcAlarmHysteresis OCTET STRING, wtWebioAn1GraphNtcAlarmDelay OCTET STRING, wtWebioAn1GraphNtcAlarmInterval OCTET STRING, wtWebioAn1GraphNtcAlarmEnable OCTET STRING, wtWebioAn1GraphNtcAlarmEMailAddr OCTET STRING, wtWebioAn1GraphNtcAlarmMailSubject OCTET STRING, wtWebioAn1GraphNtcAlarmMailText OCTET STRING, wtWebioAn1GraphNtcAlarmManagerIP OCTET STRING, wtWebioAn1GraphNtcAlarmTrapText OCTET STRING, wtWebioAn1GraphNtcAlarmMailOptions OCTET STRING, wtWebioAn1GraphNtcAlarmTcpIpAddr OCTET STRING, wtWebioAn1GraphNtcAlarmTcpPort INTEGER, wtWebioAn1GraphNtcAlarmTcpText OCTET STRING, wtWebioAn1GraphNtcAlarmClearMailSubject OCTET STRING, wtWebioAn1GraphNtcAlarmClearMailText OCTET STRING, wtWebioAn1GraphNtcAlarmClearTrapText OCTET STRING, wtWebioAn1GraphNtcAlarmClearTcpText OCTET STRING, wtWebioAn1GraphNtcAlarmSyslogIpAddr OCTET STRING, wtWebioAn1GraphNtcAlarmSyslogPort INTEGER, wtWebioAn1GraphNtcAlarmSyslogText OCTET STRING, wtWebioAn1GraphNtcAlarmFtpDataPort OCTET STRING, wtWebioAn1GraphNtcAlarmFtpFileName OCTET STRING, wtWebioAn1GraphNtcAlarmFtpText OCTET STRING, wtWebioAn1GraphNtcAlarmFtpClearText OCTET STRING, wtWebioAn1GraphNtcAlarmFtpOption OCTET STRING, wtWebioAn1GraphNtcAlarmTimerCron OCTET STRING, wtWebioAn1GraphNtcAlarmDeltaTemp OCTET STRING, wtWebioAn1GraphNtcAlarmName OCTET STRING, wtWebioAn1GraphNtcAlarmActive OCTET STRING } wtWebioAn1GraphNtcAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn1GraphNtcAlarmEntry 1 } wtWebioAn1GraphNtcAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcAlarmEntry 2 } wtWebioAn1GraphNtcAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcAlarmEntry 3 } wtWebioAn1GraphNtcAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcAlarmEntry 4 } wtWebioAn1GraphNtcAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebioAn1GraphNtcAlarmEntry 5 } wtWebioAn1GraphNtcAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioAn1GraphNtcAlarmEntry 6 } wtWebioAn1GraphNtcAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebioAn1GraphNtcAlarmEntry 7 } wtWebioAn1GraphNtcAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioAn1GraphNtcAlarmEntry 8 } wtWebioAn1GraphNtcAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioAn1GraphNtcAlarmEntry 9 } wtWebioAn1GraphNtcAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn1GraphNtcAlarmEntry 10 } wtWebioAn1GraphNtcAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebioAn1GraphNtcAlarmEntry 11 } wtWebioAn1GraphNtcAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn1GraphNtcAlarmEntry 12 } wtWebioAn1GraphNtcAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebioAn1GraphNtcAlarmEntry 13 } wtWebioAn1GraphNtcAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebioAn1GraphNtcAlarmEntry 14 } wtWebioAn1GraphNtcAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebioAn1GraphNtcAlarmEntry 15 } wtWebioAn1GraphNtcAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn1GraphNtcAlarmEntry 16 } wtWebioAn1GraphNtcAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebioAn1GraphNtcAlarmEntry 17 } wtWebioAn1GraphNtcAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION " Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebioAn1GraphNtcAlarmEntry 18 } wtWebioAn1GraphNtcAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn1GraphNtcAlarmEntry 19 } wtWebioAn1GraphNtcAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn1GraphNtcAlarmEntry 20 } wtWebioAn1GraphNtcAlarmSyslogIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn1GraphNtcAlarmEntry 21 } wtWebioAn1GraphNtcAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn1GraphNtcAlarmEntry 22 } wtWebioAn1GraphNtcAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn1GraphNtcAlarmEntry 23 } wtWebioAn1GraphNtcAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn1GraphNtcAlarmEntry 24 } wtWebioAn1GraphNtcAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioAn1GraphNtcAlarmEntry 25 } wtWebioAn1GraphNtcAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioAn1GraphNtcAlarmEntry 26 } wtWebioAn1GraphNtcAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioAn1GraphNtcAlarmEntry 27 } wtWebioAn1GraphNtcAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebioAn1GraphNtcAlarmEntry 28 } wtWebioAn1GraphNtcAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioAn1GraphNtcAlarmEntry 29 } wtWebioAn1GraphNtcAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separately. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioAn1GraphNtcAlarmEntry 30 } wtWebioAn1GraphPtAlarmDeltaTemp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum rate of change degrees/min with maximum 2 decimal places. Compared with the average of a period of 5 minutes." ::= { wtWebioAn1GraphPtAlarmEntry 31 } -- __JB__ wtWebioAn1GraphPtAlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert name" ::= { wtWebioAn1GraphPtAlarmEntry 39 } -- __JB__ wtWebioAn1GraphPtAlarmActive OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert active 1 = ON 0 = OFF" ::= { wtWebioAn1GraphPtAlarmEntry 40 } -- wtWebioAn1GraphNtcGraphicsBase Group ---------------------------- wtWebioAn1GraphNtcGraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5 : Show Logo Bit 6-7: unused" ::= { wtWebioAn1GraphNtcGraphicsBase 1 } wtWebioAn1GraphNtcGraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebioAn1GraphNtcGraphicsBase 2 } wtWebioAn1GraphNtcGraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebioAn1GraphNtcGraphicsBase 3 } wtWebioAn1GraphNtcGraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebioAn1GraphNtcGraphicsBase 4 } wtWebioAn1GraphNtcGraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebioAn1GraphNtcGraphicsBase 5 } wtWebioAn1GraphNtcGraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebioAn1GraphNtcGraphicsBase 6 } -- wtWebioAn1GraphNtcGraphicsSelect Group ---------------------------- wtWebioAn1GraphNtcGraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused" ::= { wtWebioAn1GraphNtcGraphicsSelect 1 } wtWebioAn1GraphNtcGraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Sensor 1 Bit 1-7: unused" ::= { wtWebioAn1GraphNtcGraphicsSelect 2 } -- Graph Sensor Color Table wtWebioAn1GraphNtc2SensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtc2SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn1GraphNtcGraphicsSelect 3 } wtWebioAn1GraphNtc2SensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtc2SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtc2SensorColorTable 1 } WtWebioAn1GraphNtc2SensorColorEntry ::= SEQUENCE { wtWebioAn1GraphNtcGraphicsSensorColor OCTET STRING, wtWebioAn1GraphNtcGraphicsSelectScale OCTET STRING } wtWebioAn1GraphNtcGraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn1GraphNtc2SensorColorEntry 1 } wtWebioAn1GraphNtcGraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1-7: unused" ::= { wtWebioAn1GraphNtc2SensorColorEntry 2 } -- wtWebioAn1GraphNtcGraphicsScale Group ---------------------------- wtWebioAn1GraphNtcGraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1-7: unused" ::= { wtWebioAn1GraphNtcGraphicsScale 1 } wtWebioAn1GraphNtcGraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1-7: unused" ::= { wtWebioAn1GraphNtcGraphicsScale 2 } wtWebioAn1GraphNtcGraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebioAn1GraphNtcGraphicsScale 3 } wtWebioAn1GraphNtcGraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebioAn1GraphNtcGraphicsScale 4 } wtWebioAn1GraphNtcGraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Minimum." ::= { wtWebioAn1GraphNtcGraphicsScale 5 } wtWebioAn1GraphNtcGraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Minimum." ::= { wtWebioAn1GraphNtcGraphicsScale 6 } wtWebioAn1GraphNtcGraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebioAn1GraphNtcGraphicsScale 7 } wtWebioAn1GraphNtcGraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebioAn1GraphNtcGraphicsScale 8 } wtWebioAn1GraphNtcGraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Maximum." ::= { wtWebioAn1GraphNtcGraphicsScale 9 } wtWebioAn1GraphNtcGraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Maximum." ::= { wtWebioAn1GraphNtcGraphicsScale 10 } wtWebioAn1GraphNtcGraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebioAn1GraphNtcGraphicsScale 11 } wtWebioAn1GraphNtcGraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebioAn1GraphNtcGraphicsScale 12 } wtWebioAn1GraphNtcGraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Unit." ::= { wtWebioAn1GraphNtcGraphicsScale 13 } wtWebioAn1GraphNtcGraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Unit." ::= { wtWebioAn1GraphNtcGraphicsScale 14 } -- wtWebioAn1GraphNtcPorts Group ---------------------------- -- Table wtWebioAn1GraphNtcPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn1GraphNtcPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebioAn1GraphNtcPorts 1 } wtWebioAn1GraphNtcPortEntry OBJECT-TYPE SYNTAX WtWebioAn1GraphNtcPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebioAn1GraphNtcSensorNo } ::= { wtWebioAn1GraphNtcPortTable 1 } WtWebioAn1GraphNtcPortEntry ::= SEQUENCE { wtWebioAn1GraphNtcPortName OCTET STRING, wtWebioAn1GraphNtcPortText OCTET STRING, wtWebioAn1GraphNtcPortOffset1 OCTET STRING, wtWebioAn1GraphNtcPortTemperature1 OCTET STRING, wtWebioAn1GraphNtcPortOffset2 OCTET STRING, wtWebioAn1GraphNtcPortTemperature2 OCTET STRING, wtWebioAn1GraphNtcPortComment OCTET STRING } wtWebioAn1GraphNtcPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebioAn1GraphNtcPortEntry 1 } wtWebioAn1GraphNtcPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebioAn1GraphNtcPortEntry 2 } wtWebioAn1GraphNtcPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1." ::= { wtWebioAn1GraphNtcPortEntry 3 } wtWebioAn1GraphNtcPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcPortEntry 4 } wtWebioAn1GraphNtcPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2." ::= { wtWebioAn1GraphNtcPortEntry 5 } wtWebioAn1GraphNtcPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn1GraphNtcPortEntry 6 } wtWebioAn1GraphNtcPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebioAn1GraphNtcPortEntry 7 } -- wtWebioAn1GraphNtcManufact Group ---------------------------- wtWebioAn1GraphNtcMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioAn1GraphNtcManufact 1 } wtWebioAn1GraphNtcMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioAn1GraphNtcManufact 2 } wtWebioAn1GraphNtcMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioAn1GraphNtcManufact 3 } wtWebioAn1GraphNtcMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioAn1GraphNtcManufact 4 } wtWebioAn1GraphNtcMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioAn1GraphNtcManufact 5 } wtWebioAn1GraphNtcMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioAn1GraphNtcManufact 6 } -- wtWebioAn1GraphNtcDiag Group ---------------------------- wtWebioAn1GraphNtcDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioAn1GraphNtcDiag 1 } wtWebioAn1GraphNtcDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioAn1GraphNtcDiag 2 } wtWebioAn1GraphNtcDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioAn1GraphNtcDiagErrorMessage. Errors are numbered from 1 to wtWebioAn1GraphNtcDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn1GraphNtcDiagErrorMessage." ::= { wtWebioAn1GraphNtcDiag 3 } wtWebioAn1GraphNtcDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioAn1GraphNtcDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioAn1GraphNtcDiag 4 } wtWebioAn1GraphNtcDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioAn1GraphNtcDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioAn1GraphNtcAlert1 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebioAn1GraphNtcAlert2 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebioAn1GraphNtcAlert3 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebioAn1GraphNtcAlert4 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebioAn1GraphNtcAlert5 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebioAn1GraphNtcAlert6 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebioAn1GraphNtcAlert7 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebioAn1GraphNtcAlert8 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebioAn1GraphNtcAlert9 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebioAn1GraphNtcAlert10 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebioAn1GraphNtcAlert11 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebioAn1GraphNtcAlert12 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebioAn1GraphNtcAlert13 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebioAn1GraphNtcAlert14 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebioAn1GraphNtcAlert15 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebioAn1GraphNtcAlert16 TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebioAn1GraphNtcAlertDiag TRAP-TYPE ENTERPRISE wtWebioAn1GraphNtc VARIABLES { wtWebioAn1GraphNtcDiagErrorIndex, wtWebioAn1GraphNtcDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END