WebGraph-AnalogIO-57761-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.31 ---------------------------------------------------------------- -- 27.03.2018 New: Mail Auth, SNMP destination port -- Binary HttpPort, time base report -- MQTT, REST ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 08.01.2010 New: Reports -- ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 01.10.2009 Webio -- New Analog Out: 57761 ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 02.12.2008 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 25.11.2005 #57641, WebGraph AnalogIn -- OID correction ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57641, WebGraph AnalogIn -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57641, WebGraph AnalogIn -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 17.05.2005 #57641, WebGraph AnalogIn -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57606, WebGraph Thermo-Hygrometer -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 08.09.2004 #57606 WebGraph Thermo-Hygrometer -- New: -- wtWebGraphThermHygroAlarmRHMin -- wtWebGraphThermHygroAlarmRHMax -- wtWebGraphThermHygroAlarmRHHysteresis -- wtWebGraphThermHygroPortSensorSelect -- wtWebGraphThermHygroAlarmDeltaTemp -- wtWebGraphThermHygroAlarmAHMin -- wtWebGraphThermHygroAlarmAHMax ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebGraph Tree wtWebGraphAnalog57761 OBJECT IDENTIFIER ::= { wtWebio 28 } -- wtWebGraphAnalog57761 Tree wtWebGraphAnalog57761Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761 1 } wtWebGraphAnalog57761SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761 2 } wtWebGraphAnalog57761Config OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761 3 } wtWebGraphAnalog57761Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761 4 } -- wtWebGraphAnalog57761Config Tree wtWebGraphAnalog57761Device OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Config 1 } wtWebGraphAnalog57761Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Config 2 } wtWebGraphAnalog57761Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Config 3 } -- wtWebGraphAnalog57761Device Tree wtWebGraphAnalog57761Text OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 1 } wtWebGraphAnalog57761TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 2 } wtWebGraphAnalog57761Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 3 } wtWebGraphAnalog57761Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 4 } wtWebGraphAnalog57761Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 5 } wtWebGraphAnalog57761Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Device 6 } -- wtWebGraphAnalog57761TimeDate Tree wtWebGraphAnalog57761TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761TimeDate 1 } wtWebGraphAnalog57761TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761TimeDate 2 } wtWebGraphAnalog57761DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761TimeDate 3 } -- wtWebGraphAnalog57761Basic Tree wtWebGraphAnalog57761Network OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 1 } wtWebGraphAnalog57761HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 2 } wtWebGraphAnalog57761Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 3 } wtWebGraphAnalog57761SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 4 } wtWebGraphAnalog57761UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 5 } wtWebGraphAnalog57761Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 6 } wtWebGraphAnalog57761FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 7 } wtWebGraphAnalog57761Language OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 8 } wtWebGraphAnalog57761Binary OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 9 } wtWebGraphAnalog57761MQTT OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 12 } wtWebGraphAnalog57761REST OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Basic 13 } -- wtWebGraphAnalog57761Graphics Tree wtWebGraphAnalog57761GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Graphics 1 } wtWebGraphAnalog57761GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Graphics 2 } wtWebGraphAnalog57761GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalog57761Graphics 3 } -- wtWebGraphAnalog57761Inventory Group ------------------------ wtWebGraphAnalog57761Sensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensors" ::= { wtWebGraphAnalog57761Inventory 1 } -- Interface Table wtWebGraphAnalog57761SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebGraphAnalog57761Inventory 2 } wtWebGraphAnalog57761SensorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor numbers." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761SensorTable 1 } WtWebGraphAnalog57761SensorEntry ::= SEQUENCE { wtWebGraphAnalog57761SensorNo INTEGER } wtWebGraphAnalog57761SensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor number." ::= { wtWebGraphAnalog57761SensorEntry 1 } -- wtWebGraphAnalog57761Values Table wtWebGraphAnalog57761ValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57761Inventory 3 } wtWebGraphAnalog57761ValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761ValuesTable 1 } WtWebGraphAnalog57761ValuesEntry ::= SEQUENCE{ wtWebGraphAnalog57761Values OCTET STRING } wtWebGraphAnalog57761Values OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-write STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57761ValuesEntry 1 } -- wtWebGraphAnalog57761BinaryValues Table wtWebGraphAnalog57761BinaryValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57761Inventory 4 } wtWebGraphAnalog57761BinaryValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary measurement values of the sensors." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761BinaryValuesTable 1 } WtWebGraphAnalog57761BinaryValuesEntry ::= SEQUENCE{ wtWebGraphAnalog57761BinaryValues INTEGER } wtWebGraphAnalog57761BinaryValues OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Binary measurement value of the sensor in 1/1000, signed number, 0x7FFFFFFF indicates an invalid value. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57761BinaryValuesEntry 1 } -- wtWebGraphAnalog57761ValuesPoint Table wtWebGraphAnalog57761ValuesPointTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761ValuesPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalog57761Inventory 8 } wtWebGraphAnalog57761ValuesPointEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761ValuesPointEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761ValuesPointTable 1 } WtWebGraphAnalog57761ValuesPointEntry ::= SEQUENCE{ wtWebGraphAnalog57761ValuesPoint OCTET STRING } wtWebGraphAnalog57761ValuesPoint OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-write STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII. This value will be translated according to the ports settings for the read and write operations." ::= { wtWebGraphAnalog57761ValuesPointEntry 1 } -- wtWebGraphAnalog57761SessCntrl Group -------------------------------- wtWebGraphAnalog57761SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalog57761SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebGraphAnalog57761SessCntrl 1 } wtWebGraphAnalog57761SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761SessCntrl-NoSession(0), wtWebGraphAnalog57761SessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebGraphAnalog57761SessCntrl 2 } wtWebGraphAnalog57761SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebGraphAnalog57761SessCntrl 3 } wtWebGraphAnalog57761SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebGraphAnalog57761SessCntrl 4 } wtWebGraphAnalog57761SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebGraphAnalog57761SessCntrl 5 } -- wtWebGraphAnalog57761Text Group ------------------------ wtWebGraphAnalog57761DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebGraphAnalog57761Text 1 } wtWebGraphAnalog57761DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebGraphAnalog57761Text 2 } wtWebGraphAnalog57761DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebGraphAnalog57761Text 3 } wtWebGraphAnalog57761DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebGraphAnalog57761Text 4 } -- wtWebGraphAnalog57761TimeZone Group ---------------------------- wtWebGraphAnalog57761TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 1 } wtWebGraphAnalog57761TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 2 } wtWebGraphAnalog57761TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebGraphAnalog57761TimeZone 3 } wtWebGraphAnalog57761StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 4 } wtWebGraphAnalog57761StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 5 } wtWebGraphAnalog57761StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebGraphAnalog57761TimeZone 6 } wtWebGraphAnalog57761StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StartMonth-January(1), wtWebGraphAnalog57761StartMonth-February(2), wtWebGraphAnalog57761StartMonth-March(3), wtWebGraphAnalog57761StartMonth-April(4), wtWebGraphAnalog57761StartMonth-May(5), wtWebGraphAnalog57761StartMonth-June(6), wtWebGraphAnalog57761StartMonth-July(7), wtWebGraphAnalog57761StartMonth-August(8), wtWebGraphAnalog57761StartMonth-September(9), wtWebGraphAnalog57761StartMonth-October(10), wtWebGraphAnalog57761StartMonth-November(11), wtWebGraphAnalog57761StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebGraphAnalog57761TimeZone 7 } wtWebGraphAnalog57761StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StartMode-first(1), wtWebGraphAnalog57761StartMode-second(2), wtWebGraphAnalog57761StartMode-third(3), wtWebGraphAnalog57761StartMode-fourth(4), wtWebGraphAnalog57761StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebGraphAnalog57761TimeZone 8 } wtWebGraphAnalog57761StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StartWday-Sunday(1), wtWebGraphAnalog57761StartWday-Monday(2), wtWebGraphAnalog57761StartWday-Tuesday(3), wtWebGraphAnalog57761StartWday-Thursday(4), wtWebGraphAnalog57761StartWday-Wednesday(5), wtWebGraphAnalog57761StartWday-Friday(6), wtWebGraphAnalog57761StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebGraphAnalog57761TimeZone 9 } wtWebGraphAnalog57761StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 10 } wtWebGraphAnalog57761StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 11 } wtWebGraphAnalog57761StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StopMonth-January(1), wtWebGraphAnalog57761StopMonth-February(2), wtWebGraphAnalog57761StopMonth-March(3), wtWebGraphAnalog57761StopMonth-April(4), wtWebGraphAnalog57761StopMonth-May(5), wtWebGraphAnalog57761StopMonth-June(6), wtWebGraphAnalog57761StopMonth-July(7), wtWebGraphAnalog57761StopMonth-August(8), wtWebGraphAnalog57761StopMonth-September(9), wtWebGraphAnalog57761StopMonth-October(10), wtWebGraphAnalog57761StopMonth-November(11), wtWebGraphAnalog57761StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57761TimeZone 12 } wtWebGraphAnalog57761StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StopMode-first(1), wtWebGraphAnalog57761StopMode-second(2), wtWebGraphAnalog57761StopMode-third(3), wtWebGraphAnalog57761StopMode-fourth(4), wtWebGraphAnalog57761StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57761TimeZone 13 } wtWebGraphAnalog57761StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761StopWday-Sunday(1), wtWebGraphAnalog57761StopWday-Monday(2), wtWebGraphAnalog57761StopWday-Tuesday(3), wtWebGraphAnalog57761StopWday-Thursday(4), wtWebGraphAnalog57761StopWday-Wednesday(5), wtWebGraphAnalog57761StopWday-Friday(6), wtWebGraphAnalog57761StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebGraphAnalog57761TimeZone 14 } wtWebGraphAnalog57761StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 15 } wtWebGraphAnalog57761StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalog57761TimeZone 16 } -- wtWebGraphAnalog57761TimeServer Group ---------------------------- wtWebGraphAnalog57761TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebGraphAnalog57761TimeServer 1 } wtWebGraphAnalog57761TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebGraphAnalog57761TimeServer 2 } wtWebGraphAnalog57761TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebGraphAnalog57761TimeServer 3 } wtWebGraphAnalog57761TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebGraphAnalog57761TimeServer 4 } -- wtWebGraphAnalog57761DeviceClock Group ---------------------------- wtWebGraphAnalog57761ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebGraphAnalog57761DeviceClock 1 } wtWebGraphAnalog57761ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebGraphAnalog57761DeviceClock 2 } wtWebGraphAnalog57761ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebGraphAnalog57761DeviceClock 3 } wtWebGraphAnalog57761ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761ClockMonth-January(1), wtWebGraphAnalog57761ClockMonth-February(2), wtWebGraphAnalog57761ClockMonth-March(3), wtWebGraphAnalog57761ClockMonth-April(4), wtWebGraphAnalog57761ClockMonth-May(5), wtWebGraphAnalog57761ClockMonth-June(6), wtWebGraphAnalog57761ClockMonth-July(7), wtWebGraphAnalog57761ClockMonth-August(8), wtWebGraphAnalog57761ClockMonth-September(9), wtWebGraphAnalog57761ClockMonth-October(10), wtWebGraphAnalog57761ClockMonth-November(11), wtWebGraphAnalog57761ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebGraphAnalog57761DeviceClock 4 } wtWebGraphAnalog57761ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebGraphAnalog57761DeviceClock 5 } -- wtWebGraphAnalog57761Network Group ------------------------ wtWebGraphAnalog57761IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebGraphAnalog57761Network 1 } wtWebGraphAnalog57761SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebGraphAnalog57761Network 2 } wtWebGraphAnalog57761Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebGraphAnalog57761Network 3 } wtWebGraphAnalog57761DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebGraphAnalog57761Network 4 } wtWebGraphAnalog57761DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebGraphAnalog57761Network 5 } wtWebGraphAnalog57761AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebGraphAnalog57761Network 6 } -- wtWebGraphAnalog57761HTTP Group -------------------------------- wtWebGraphAnalog57761Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebGraphAnalog57761HTTP 1 } wtWebGraphAnalog57761GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebGraphAnalog57761HTTP 2 } wtWebGraphAnalog57761HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebGraphAnalog57761HTTP 3 } -- wtWebGraphAnalog57761Mail Group -------------------------------- wtWebGraphAnalog57761MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebGraphAnalog57761Mail 1 } wtWebGraphAnalog57761MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebGraphAnalog57761Mail 2 } wtWebGraphAnalog57761MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebGraphAnalog57761Mail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebGraphAnalog57761Mail 4 } wtWebGraphAnalog57761MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebGraphAnalog57761Mail 5 } wtWebGraphAnalog57761MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebGraphAnalog57761Mail 6 } wtWebGraphAnalog57761MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebGraphAnalog57761Mail 7 } wtWebGraphAnalog57761MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebGraphAnalog57761Mail 8 } -- wtWebGraphAnalog57761SNMP Group -------------------------------- wtWebGraphAnalog57761SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebGraphAnalog57761SNMP 1 } wtWebGraphAnalog57761SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebGraphAnalog57761SNMP 2 } wtWebGraphAnalog57761SystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebGraphAnalog57761SNMP 3 } wtWebGraphAnalog57761SystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebGraphAnalog57761SNMP 4 } wtWebGraphAnalog57761SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebGraphAnalog57761SNMP 5 } wtWebGraphAnalog57761SnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebGraphAnalog57761SNMP 6 } wtWebGraphAnalog57761SnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebGraphAnalog57761SNMP 7 } -- wtWebGraphAnalog57761UDP Group -------------------------------- wtWebGraphAnalog57761UdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebGraphAnalog57761UDP 1 } wtWebGraphAnalog57761UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebGraphAnalog57761UDP 2 } -- wtWebGraphAnalog57761Syslog Group -------------------------------- wtWebGraphAnalog57761SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebGraphAnalog57761Syslog 1 } wtWebGraphAnalog57761SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebGraphAnalog57761Syslog 2 } wtWebGraphAnalog57761SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebGraphAnalog57761Syslog 3 } wtWebGraphAnalog57761SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebGraphAnalog57761Syslog 4 } -- wtWebGraphAnalog57761FTP Group -------------------------------- wtWebGraphAnalog57761FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebGraphAnalog57761FTP 1 } wtWebGraphAnalog57761FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebGraphAnalog57761FTP 2 } wtWebGraphAnalog57761FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebGraphAnalog57761FTP 3 } wtWebGraphAnalog57761FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebGraphAnalog57761FTP 4 } wtWebGraphAnalog57761FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebGraphAnalog57761FTP 5 } wtWebGraphAnalog57761FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebGraphAnalog57761FTP 6 } wtWebGraphAnalog57761FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebGraphAnalog57761FTP 7 } -- wtWebGraphAnalog57761Language Group -------------------------------- wtWebGraphAnalog57761LanguageSelect OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German" ::= { wtWebGraphAnalog57761Language 1 } -- wtWebGraphAnalog57761Binary Group -------------------------------- wtWebGraphAnalog57761BinaryModeCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent binary channels." ::= { wtWebGraphAnalog57761Binary 1 } -- Binary Interface Table wtWebGraphAnalog57761BinaryIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of indices." ::= { wtWebGraphAnalog57761Binary 2 } wtWebGraphAnalog57761BinaryIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761BinaryIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Indices of the binary channels." INDEX { wtWebGraphAnalog57761BinaryModeNo } ::= { wtWebGraphAnalog57761BinaryIfTable 1 } WtWebGraphAnalog57761BinaryIfEntry ::= SEQUENCE { wtWebGraphAnalog57761BinaryModeNo INTEGER } wtWebGraphAnalog57761BinaryModeNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of the binary channel." ::= { wtWebGraphAnalog57761BinaryIfEntry 1 } -- Binary Table -------------------------------- wtWebGraphAnalog57761BinaryTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of properties of the binary mode." ::= { wtWebGraphAnalog57761Binary 3 } wtWebGraphAnalog57761BinaryEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761BinaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary properties." INDEX { wtWebGraphAnalog57761BinaryModeNo } ::= { wtWebGraphAnalog57761BinaryTable 1 } WtWebGraphAnalog57761BinaryEntry ::= SEQUENCE { wtWebGraphAnalog57761BinaryOperationMode OCTET STRING, wtWebGraphAnalog57761BinaryTcpServerLocalPort INTEGER, wtWebGraphAnalog57761BinaryTcpServerInputTrigger OCTET STRING, wtWebGraphAnalog57761BinaryTcpServerApplicationMode OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientLocalPort INTEGER, wtWebGraphAnalog57761BinaryTcpClientServerPort INTEGER, wtWebGraphAnalog57761BinaryTcpClientServerIpAddr OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientServerPassword OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientInactivity INTEGER, wtWebGraphAnalog57761BinaryTcpClientInputTrigger OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientInterval INTEGER, wtWebGraphAnalog57761BinaryTcpClientApplicationMode OCTET STRING, wtWebGraphAnalog57761BinaryUdpPeerLocalPort INTEGER, wtWebGraphAnalog57761BinaryUdpPeerRemotePort INTEGER, wtWebGraphAnalog57761BinaryUdpPeerRemoteIpAddr OCTET STRING, wtWebGraphAnalog57761BinaryUdpPeerInputTrigger OCTET STRING, wtWebGraphAnalog57761BinaryUdpPeerInterval INTEGER, wtWebGraphAnalog57761BinaryUdpPeerApplicationMode OCTET STRING, wtWebGraphAnalog57761BinaryConnectedPort INTEGER, wtWebGraphAnalog57761BinaryConnectedIpAddr IpAddress, wtWebGraphAnalog57761BinaryTcpServerClientHttpPort INTEGER, wtWebGraphAnalog57761BinaryTcpClientServerHttpPort INTEGER, wtWebGraphAnalog57761BinaryTcpServerHysteresis1 OCTET STRING, wtWebGraphAnalog57761BinaryTcpServerHysteresis2 OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientHysteresis1 OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientHysteresis2 OCTET STRING, wtWebGraphAnalog57761BinaryUdpPeerHysteresis1 OCTET STRING, wtWebGraphAnalog57761BinaryUdpPeerHysteresis2 OCTET STRING, wtWebGraphAnalog57761BinaryTcpClientServerUserName OCTET STRING } wtWebGraphAnalog57761BinaryOperationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the operation mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : UDP Peer Bit 1 : TCP Client Bit 0 : TCP Server" ::= { wtWebGraphAnalog57761BinaryEntry 1 } wtWebGraphAnalog57761BinaryTcpServerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this server mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57761BinaryEntry 2 } wtWebGraphAnalog57761BinaryTcpServerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57761BinaryEntry 3 } wtWebGraphAnalog57761BinaryTcpServerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 4-7: unused Bit 3 : OPC Device Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57761BinaryEntry 4 } wtWebGraphAnalog57761BinaryTcpClientLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local TCP port for data exchange in this client mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57761BinaryEntry 5 } wtWebGraphAnalog57761BinaryTcpClientServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server port to zero." ::= { wtWebGraphAnalog57761BinaryEntry 6 } wtWebGraphAnalog57761BinaryTcpClientServerIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the server. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the server IP address to 0.0.0.0." ::= { wtWebGraphAnalog57761BinaryEntry 7 } wtWebGraphAnalog57761BinaryTcpClientServerPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by the administrator password of the server. Enter the server password to establish the connection, if a server administrator password exists." ::= { wtWebGraphAnalog57761BinaryEntry 8 } wtWebGraphAnalog57761BinaryTcpClientInactivity OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Connection timeout in 100ms. If no data are exchanged within the specified time, the device closes the connection to the server. The value 0 deactivates the timer. Using the Box2Box mode this function is disabled." ::= { wtWebGraphAnalog57761BinaryEntry 9 } wtWebGraphAnalog57761BinaryTcpClientInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57761BinaryEntry 10 } wtWebGraphAnalog57761BinaryTcpClientInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured application. A interval of zero stopps the periodical sending." ::= { wtWebGraphAnalog57761BinaryEntry 11 } wtWebGraphAnalog57761BinaryTcpClientApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57761BinaryEntry 12 } wtWebGraphAnalog57761BinaryUdpPeerLocalPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Local UDP port for data exchange in this peer to peer mode. This port number must be unique within the device. Reserved port number must not be used (refere to the manual)." ::= { wtWebGraphAnalog57761BinaryEntry 13 } wtWebGraphAnalog57761BinaryUdpPeerRemotePort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote port to zero." ::= { wtWebGraphAnalog57761BinaryEntry 14 } wtWebGraphAnalog57761BinaryUdpPeerRemoteIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Ip address of the remote device. A complete set of port number, IP address and a valid input/output mask starts this mode. No data exchange take place when setting the remote device IP address to 0.0.0.0." ::= { wtWebGraphAnalog57761BinaryEntry 15 } wtWebGraphAnalog57761BinaryUdpPeerInputTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Every change on the inputs causes their state to be transmitted to the remote device. To minimize data traffic, individual inputs may be exempted from this rule. Nevertheless every transmission will contain all input states. If a bit is set (1), a change of state on the corresponding input triggers a transmission. If the bit is not set (0), no transmission takes place. The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 0-1: Analog inputs 0-1" ::= { wtWebGraphAnalog57761BinaryEntry 16 } wtWebGraphAnalog57761BinaryUdpPeerInterval OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Configurable interval with a 100ms base, in which the Webio device sends data to the configured remote device. A interval of zero stopps the periodical sending." ::= { wtWebGraphAnalog57761BinaryEntry 17 } wtWebGraphAnalog57761BinaryUdpPeerApplicationMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the application mode: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : Box2Box Slave Bit 1 : Compatible 50xxx Bit 0 : Default" ::= { wtWebGraphAnalog57761BinaryEntry 18 } wtWebGraphAnalog57761BinaryConnectedPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of the remote device, after connection has been established. In case of no connection or missing port informations a zero will be read." ::= { wtWebGraphAnalog57761BinaryEntry 19 } wtWebGraphAnalog57761BinaryConnectedIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "IP address of the remote device, after connection has been established. In case of no connection or missing port informations 0.0.0.0 will be read." ::= { wtWebGraphAnalog57761BinaryEntry 20 } wtWebGraphAnalog57761BinaryTcpServerClientHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs status informations will be send to this port. Not used at mode Compatible 50xxx." ::= { wtWebGraphAnalog57761BinaryEntry 21 } wtWebGraphAnalog57761BinaryTcpClientServerHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP port number of the remote device at TCP Client Mode. In the operating mode Box2Box connection status informations will be exchanged through this port." ::= { wtWebGraphAnalog57761BinaryEntry 22 } wtWebGraphAnalog57761BinaryTcpServerHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 23 } wtWebGraphAnalog57761BinaryTcpServerHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpServerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 24 } wtWebGraphAnalog57761BinaryTcpClientHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 25 } wtWebGraphAnalog57761BinaryTcpClientHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryTcpClientInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 26 } wtWebGraphAnalog57761BinaryUdpPeerHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 1 must be selected at wtWebGraphAnalog57761BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 27 } wtWebGraphAnalog57761BinaryUdpPeerHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "A change greater than this value initiate a transmission of the corresponding input value. The input 2 must be selected at wtWebGraphAnalog57761BinaryUdpPeerInputTrigger. With a hysteresis of zero any change will be transmitted." ::= { wtWebGraphAnalog57761BinaryEntry 28 } wtWebGraphAnalog57761BinaryTcpClientServerUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Building a connection may be protected by a specific user name within the server. Enter the user name to establish the connection, if a user name entry exists." ::= { wtWebGraphAnalog57761BinaryEntry 29 } -- wtWebGraphAnalog57761MQTT Group -------------------------------- wtWebGraphAnalog57761MQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable" ::= { wtWebGraphAnalog57761MQTT 1 } wtWebGraphAnalog57761MQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebGraphAnalog57761MQTT 2 } wtWebGraphAnalog57761MQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebGraphAnalog57761MQTT 3 } wtWebGraphAnalog57761MQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebGraphAnalog57761MQTT 4 } wtWebGraphAnalog57761MQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebGraphAnalog57761MQTT 5 } wtWebGraphAnalog57761MQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebGraphAnalog57761MQTT 6 } wtWebGraphAnalog57761MQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebGraphAnalog57761MQTT 7 } wtWebGraphAnalog57761MQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebGraphAnalog57761MQTT 8 } wtWebGraphAnalog57761MQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebGraphAnalog57761MQTT 9 } wtWebGraphAnalog57761MQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebGraphAnalog57761MQTT 10 } wtWebGraphAnalog57761MQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebGraphAnalog57761MQTT 11 } wtWebGraphAnalog57761MQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebGraphAnalog57761MQTT 12 } wtWebGraphAnalog57761MQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebGraphAnalog57761MQTT 13 } wtWebGraphAnalog57761MQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebGraphAnalog57761MQTT 14 } -- wtWebGraphAnalog57761REST Group -------------------------------- wtWebGraphAnalog57761RESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST : Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebGraphAnalog57761REST 1 } wtWebGraphAnalog57761RESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebGraphAnalog57761REST 2 } -- wtWebGraphAnalog57761Datalogger Group -------------------------------- wtWebGraphAnalog57761LoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalog57761Datalogger-15Sec(1), wtWebGraphAnalog57761Datalogger-30Sec(2), wtWebGraphAnalog57761Datalogger-1Min(3), wtWebGraphAnalog57761Datalogger-5Min(4), wtWebGraphAnalog57761Datalogger-15Min(5), wtWebGraphAnalog57761Datalogger-60Min(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebGraphAnalog57761Datalogger 1 } wtWebGraphAnalog57761LoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57761Datalogger 2 } -- wtWebGraphAnalog57761Alarm Group ---------------------------- wtWebGraphAnalog57761AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebGraphAnalog57761Alarm 1 } -- Alarm Interface Table wtWebGraphAnalog57761AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebGraphAnalog57761Alarm 2 } wtWebGraphAnalog57761AlarmIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebGraphAnalog57761AlarmNo } ::= { wtWebGraphAnalog57761AlarmIfTable 1 } WtWebGraphAnalog57761AlarmIfEntry ::= SEQUENCE { wtWebGraphAnalog57761AlarmNo INTEGER } wtWebGraphAnalog57761AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebGraphAnalog57761AlarmIfEntry 1 } -- Alarm Table wtWebGraphAnalog57761AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebGraphAnalog57761Alarm 3 } wtWebGraphAnalog57761AlarmEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebGraphAnalog57761AlarmNo } ::= { wtWebGraphAnalog57761AlarmTable 1 } WtWebGraphAnalog57761AlarmEntry ::= SEQUENCE { wtWebGraphAnalog57761AlarmTrigger OCTET STRING, wtWebGraphAnalog57761AlarmMin1 OCTET STRING, wtWebGraphAnalog57761AlarmMax1 OCTET STRING, wtWebGraphAnalog57761AlarmHysteresis1 OCTET STRING, wtWebGraphAnalog57761AlarmDelay OCTET STRING, wtWebGraphAnalog57761AlarmInterval OCTET STRING, wtWebGraphAnalog57761AlarmEnable OCTET STRING, wtWebGraphAnalog57761AlarmEMailAddr OCTET STRING, wtWebGraphAnalog57761AlarmMailSubject OCTET STRING, wtWebGraphAnalog57761AlarmMailText OCTET STRING, wtWebGraphAnalog57761AlarmManagerIP OCTET STRING, wtWebGraphAnalog57761AlarmTrapText OCTET STRING, wtWebGraphAnalog57761AlarmMailOptions OCTET STRING, wtWebGraphAnalog57761AlarmTcpIpAddr OCTET STRING, wtWebGraphAnalog57761AlarmTcpPort INTEGER, wtWebGraphAnalog57761AlarmTcpText OCTET STRING, wtWebGraphAnalog57761AlarmClearMailSubject OCTET STRING, wtWebGraphAnalog57761AlarmClearMailText OCTET STRING, wtWebGraphAnalog57761AlarmClearTrapText OCTET STRING, wtWebGraphAnalog57761AlarmClearTcpText OCTET STRING, wtWebGraphAnalog57761AlarmMin2 OCTET STRING, wtWebGraphAnalog57761AlarmMax2 OCTET STRING, wtWebGraphAnalog57761AlarmHysteresis2 OCTET STRING, wtWebGraphAnalog57761AlarmSyslogIpAddr OCTET STRING, wtWebGraphAnalog57761AlarmSyslogPort INTEGER, wtWebGraphAnalog57761AlarmSyslogText OCTET STRING, wtWebGraphAnalog57761AlarmSyslogClearText OCTET STRING, wtWebGraphAnalog57761AlarmFtpDataPort OCTET STRING, wtWebGraphAnalog57761AlarmFtpFileName OCTET STRING, wtWebGraphAnalog57761AlarmFtpText OCTET STRING, wtWebGraphAnalog57761AlarmFtpClearText OCTET STRING, wtWebGraphAnalog57761AlarmFtpOption OCTET STRING, wtWebGraphAnalog57761AlarmTimerCron OCTET STRING, wtWebGraphAnalog57761AlarmDeltaTemp OCTET STRING, wtWebGraphAnalog57761AlarmName OCTET STRING, wtWebGraphAnalog57761AlarmActive OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqAuthEnable OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqAuthUser OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqAuthPassword OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqSetUrl OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqClearUrl OCTET STRING, wtWebGraphAnalog57761AlarmHttpReqServerPort INTEGER, wtWebGraphAnalog57761AlarmMqttTopicPath OCTET STRING, wtWebGraphAnalog57761AlarmMqttTopicSetTopic OCTET STRING, wtWebGraphAnalog57761AlarmMqttTopicClear OCTET STRING, wtWebGraphAnalog57761AlarmSensorLostSelection OCTET STRING, wtWebGraphAnalog57761AlarmLimitWindow OCTET STRING, wtWebGraphAnalog57761AlarmSnmpManagerPort INTEGER, wtWebGraphAnalog57761AlarmMqttQoS OCTET STRING, wtWebGraphAnalog57761AlarmMqttRetain OCTET STRING } wtWebGraphAnalog57761AlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57761AlarmEntry 1 } wtWebGraphAnalog57761AlarmMin1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum sensor 1 with maximum 3 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 2 } wtWebGraphAnalog57761AlarmMax1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum sensor 1 with maximum 3 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 3 } wtWebGraphAnalog57761AlarmHysteresis1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) with maximum 3 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 4 } wtWebGraphAnalog57761AlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebGraphAnalog57761AlarmEntry 5 } wtWebGraphAnalog57761AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebGraphAnalog57761AlarmEntry 6 } wtWebGraphAnalog57761AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable Bit 3: Syslog enable Bit 4: FTP Client enable" ::= { wtWebGraphAnalog57761AlarmEntry 7 } wtWebGraphAnalog57761AlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebGraphAnalog57761AlarmEntry 8 } wtWebGraphAnalog57761AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebGraphAnalog57761AlarmEntry 9 } wtWebGraphAnalog57761AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebGraphAnalog57761AlarmEntry 10 } wtWebGraphAnalog57761AlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebGraphAnalog57761AlarmEntry 11 } wtWebGraphAnalog57761AlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalog57761AlarmEntry 12 } wtWebGraphAnalog57761AlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Logger.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebGraphAnalog57761AlarmEntry 13 } wtWebGraphAnalog57761AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebGraphAnalog57761AlarmEntry 14 } wtWebGraphAnalog57761AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebGraphAnalog57761AlarmEntry 15 } wtWebGraphAnalog57761AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalog57761AlarmEntry 16 } wtWebGraphAnalog57761AlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebGraphAnalog57761AlarmEntry 17 } wtWebGraphAnalog57761AlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebGraphAnalog57761AlarmEntry 18 } wtWebGraphAnalog57761AlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalog57761AlarmEntry 19 } wtWebGraphAnalog57761AlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalog57761AlarmEntry 20 } wtWebGraphAnalog57761AlarmMin2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum sensor 2 with maximum 3 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 21 } wtWebGraphAnalog57761AlarmMax2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum sensor 2 with maximum 2 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 22 } wtWebGraphAnalog57761AlarmHysteresis2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hysterese rel. sensor 2 with maximum 3 decimal places." ::= { wtWebGraphAnalog57761AlarmEntry 23 } wtWebGraphAnalog57761AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalog57761AlarmEntry 24 } wtWebGraphAnalog57761AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalog57761AlarmEntry 25 } wtWebGraphAnalog57761AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebGraphAnalog57761AlarmEntry 26 } wtWebGraphAnalog57761AlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message." ::= { wtWebGraphAnalog57761AlarmEntry 27 } wtWebGraphAnalog57761AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebGraphAnalog57761AlarmEntry 28 } wtWebGraphAnalog57761AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebGraphAnalog57761AlarmEntry 29 } wtWebGraphAnalog57761AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebGraphAnalog57761AlarmEntry 30 } wtWebGraphAnalog57761AlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebGraphAnalog57761AlarmEntry 31 } wtWebGraphAnalog57761AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebGraphAnalog57761AlarmEntry 32 } wtWebGraphAnalog57761AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry defines a time window for alarm 1-8 and a activation time for the report. A time window is definied by start and stop time stamp, seperated by a space or tab. The activation time of the report is defined by a single start time stamp. Each time stamp contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger an action, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas (i.e.: 2,14,22) - a partition within the allowed range (i.e.: 1-5) - step size within a partition of the allowed range (i.e.: 0-59/2 every second minute)." ::= { wtWebGraphAnalog57761AlarmEntry 33 } -- __JB__ wtWebGraphAnalog57761AlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert name" ::= { wtWebGraphAnalog57761AlarmEntry 39 } -- __JB__ wtWebGraphAnalog57761AlarmActive OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert active 1 = ON 0 = OFF" ::= { wtWebGraphAnalog57761AlarmEntry 40 } wtWebGraphAnalog57761AlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebGraphAnalog57761AlarmEntry 61 } wtWebGraphAnalog57761AlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebGraphAnalog57761AlarmEntry 62 } wtWebGraphAnalog57761AlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebGraphAnalog57761AlarmEntry 63 } wtWebGraphAnalog57761AlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebGraphAnalog57761AlarmEntry 64 } wtWebGraphAnalog57761AlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebGraphAnalog57761AlarmEntry 65 } wtWebGraphAnalog57761AlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebGraphAnalog57761AlarmEntry 66 } wtWebGraphAnalog57761AlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebGraphAnalog57761AlarmEntry 67 } wtWebGraphAnalog57761AlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebGraphAnalog57761AlarmEntry 68 } wtWebGraphAnalog57761AlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebGraphAnalog57761AlarmEntry 69 } wtWebGraphAnalog57761AlarmSensorLostSelection OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : Sensor 0" ::= { wtWebGraphAnalog57761AlarmEntry 70 } wtWebGraphAnalog57761AlarmLimitWindow OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If window type is INSIDE the alarm is genereted when the temperature is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the minimum value or greater than the maximum value. Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : inside window Bit 0 : outside window" ::= { wtWebGraphAnalog57761AlarmEntry 71 } wtWebGraphAnalog57761AlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebGraphAnalog57761AlarmEntry 76 } wtWebGraphAnalog57761AlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebGraphAnalog57761AlarmEntry 77 } wtWebGraphAnalog57761AlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebGraphAnalog57761AlarmEntry 78 } -- wtWebGraphAnalog57761GraphicsBase Group ---------------------------- wtWebGraphAnalog57761GraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebGraphAnalog57761GraphicsBase 1 } wtWebGraphAnalog57761GraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebGraphAnalog57761GraphicsBase 2 } wtWebGraphAnalog57761GraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebGraphAnalog57761GraphicsBase 3 } wtWebGraphAnalog57761GraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebGraphAnalog57761GraphicsBase 4 } wtWebGraphAnalog57761GraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebGraphAnalog57761GraphicsBase 5 } wtWebGraphAnalog57761GraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebGraphAnalog57761GraphicsBase 6 } -- wtWebGraphAnalog57761GraphicsSelect Group ---------------------------- wtWebGraphAnalog57761GraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57761GraphicsSelect 1 } wtWebGraphAnalog57761GraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57761GraphicsSelect 2 } -- Graph Sensor Color Table wtWebGraphAnalog57761SensorColor2Table OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalog57761GraphicsSelect 3 } wtWebGraphAnalog57761SensorColor2Entry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761SensorColor2Table 1 } WtWebGraphAnalog57761SensorColor2Entry ::= SEQUENCE { wtWebGraphAnalog57761GraphicsSensorColor OCTET STRING, wtWebGraphAnalog57761GraphicsSelectScale OCTET STRING } wtWebGraphAnalog57761GraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalog57761SensorColor2Entry 1 } wtWebGraphAnalog57761GraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2-7: unused" ::= { wtWebGraphAnalog57761SensorColor2Entry 2 } -- wtWebGraphAnalog57761GraphicsScale Group ---------------------------- wtWebGraphAnalog57761GraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2-7: unused" ::= { wtWebGraphAnalog57761GraphicsScale 1 } wtWebGraphAnalog57761GraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2-7: unused" ::= { wtWebGraphAnalog57761GraphicsScale 2 } wtWebGraphAnalog57761GraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebGraphAnalog57761GraphicsScale 3 } wtWebGraphAnalog57761GraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebGraphAnalog57761GraphicsScale 4 } wtWebGraphAnalog57761GraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebGraphAnalog57761GraphicsScale 7 } wtWebGraphAnalog57761GraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebGraphAnalog57761GraphicsScale 8 } wtWebGraphAnalog57761GraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebGraphAnalog57761GraphicsScale 11 } wtWebGraphAnalog57761GraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebGraphAnalog57761GraphicsScale 12 } -- wtWebGraphAnalog57761Ports Group ---------------------------- -- Table wtWebGraphAnalog57761PortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalog57761PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebGraphAnalog57761Ports 1 } wtWebGraphAnalog57761PortEntry OBJECT-TYPE SYNTAX WtWebGraphAnalog57761PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebGraphAnalog57761SensorNo } ::= { wtWebGraphAnalog57761PortTable 1 } WtWebGraphAnalog57761PortEntry ::= SEQUENCE { wtWebGraphAnalog57761PortName OCTET STRING, wtWebGraphAnalog57761PortText OCTET STRING, wtWebGraphAnalog57761PortOffset1 OCTET STRING, wtWebGraphAnalog57761SetPoint1 OCTET STRING, wtWebGraphAnalog57761PortOffset2 OCTET STRING, wtWebGraphAnalog57761SetPoint2 OCTET STRING, wtWebGraphAnalog57761PortComment OCTET STRING, wtWebGraphAnalog57761PortSensorSelect OCTET STRING, wtWebGraphAnalog57761PortUnit OCTET STRING, wtWebGraphAnalog57761PortScale0 OCTET STRING, wtWebGraphAnalog57761PortScale100 OCTET STRING, wtWebGraphAnalog57761PortOutputMode OCTET STRING, wtWebGraphAnalog57761PortInputMode OCTET STRING, wtWebGraphAnalog57761PortPresetValue OCTET STRING } wtWebGraphAnalog57761PortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebGraphAnalog57761PortEntry 1 } wtWebGraphAnalog57761PortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebGraphAnalog57761PortEntry 2 } wtWebGraphAnalog57761PortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1." ::= { wtWebGraphAnalog57761PortEntry 3 } wtWebGraphAnalog57761SetPoint1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places." ::= { wtWebGraphAnalog57761PortEntry 4 } wtWebGraphAnalog57761PortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2." ::= { wtWebGraphAnalog57761PortEntry 5 } wtWebGraphAnalog57761SetPoint2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places." ::= { wtWebGraphAnalog57761PortEntry 6 } wtWebGraphAnalog57761PortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebGraphAnalog57761PortEntry 7 } wtWebGraphAnalog57761PortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused" ::= { wtWebGraphAnalog57761PortEntry 8 } wtWebGraphAnalog57761PortUnit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed unit." ::= { wtWebGraphAnalog57761PortEntry 9 } wtWebGraphAnalog57761PortScale0 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalog57761PortEntry 10 } wtWebGraphAnalog57761PortScale100 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalog57761PortEntry 11 } wtWebGraphAnalog57761PortOutputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded output mode defines the individual operation mode for any output. More than one mode must not be selected. If an output mode is selected, Bit 2 in wtWebGraphAnalog57761PortInputMode will be set automatically. The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 6-7: unused Bit 5 : Output OFF Bit 4 : Binary 2 Bit 3 : Binary 1 Bit 2 : SNMP Bit 1 : UDP ASCII Bit 0 : HTTP" ::= { wtWebGraphAnalog57761PortEntry 12 } wtWebGraphAnalog57761PortInputMode OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "This binary coded input mode defines the individual operation mode for any input. More than one mode must not be selected. If an input mode is selected, Bit 5 in wtWebGraphAnalog57761PortOutputMode will be set automatically. The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: unused Bit 2 : I-Output Bit 1 : I-Input, active Bit 0 : I-Input, passive" ::= { wtWebGraphAnalog57761PortEntry 13 } wtWebGraphAnalog57761PortPresetValue OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value will be set after reset or initialisation." ::= { wtWebGraphAnalog57761PortEntry 16 } -- wtWebGraphAnalog57761Manufact Group ---------------------------- wtWebGraphAnalog57761MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebGraphAnalog57761Manufact 1 } wtWebGraphAnalog57761MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebGraphAnalog57761Manufact 2 } wtWebGraphAnalog57761MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebGraphAnalog57761Manufact 3 } wtWebGraphAnalog57761MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebGraphAnalog57761Manufact 4 } wtWebGraphAnalog57761MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebGraphAnalog57761Manufact 5 } wtWebGraphAnalog57761MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebGraphAnalog57761Manufact 6 } -- wtWebGraphAnalog57761Diag Group ---------------------------- wtWebGraphAnalog57761DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebGraphAnalog57761Diag 1 } wtWebGraphAnalog57761DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebGraphAnalog57761Diag 2 } wtWebGraphAnalog57761DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebGraphAnalog57761DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAnalog57761DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAnalog57761DiagErrorMessage." ::= { wtWebGraphAnalog57761Diag 3 } wtWebGraphAnalog57761DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebGraphAnalog57761DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebGraphAnalog57761Diag 4 } wtWebGraphAnalog57761DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebGraphAnalog57761Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebGraphAnalog57761Alert1 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebGraphAnalog57761Alert2 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebGraphAnalog57761Alert3 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebGraphAnalog57761Alert4 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebGraphAnalog57761Alert5 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebGraphAnalog57761Alert6 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebGraphAnalog57761Alert7 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebGraphAnalog57761Alert8 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebGraphAnalog57761Alert9 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebGraphAnalog57761Alert10 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebGraphAnalog57761Alert11 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebGraphAnalog57761Alert12 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebGraphAnalog57761Alert13 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebGraphAnalog57761Alert14 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebGraphAnalog57761Alert15 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebGraphAnalog57761Alert16 TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebGraphAnalog57761AlertReport TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761AlarmTrapText } DESCRIPTION "This SNMP trap is generated when the report was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Report" --#SUMMARY "Report: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 39 wtWebGraphAnalog57761AlertDiag TRAP-TYPE ENTERPRISE wtWebGraphAnalog57761 VARIABLES { wtWebGraphAnalog57761DiagErrorIndex, wtWebGraphAnalog57761DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-IO Analog-InOut Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END