WebGraph-2xThermometer-US-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.35 ---------------------------------------------------------------- -- 28.06.2018 New: -- systax errors corrected ---------------------------------------------------------------- -- Revison: 1.34 ---------------------------------------------------------------- -- 12.12.2017 New: -- wtWebioAn2GraphMQTTLastWillEnable -- wtWebioAn2GraphMQTTLastWillTopic -- wtWebioAn2GraphMQTTLastWillMsg -- wtWebioAn2GraphMQTTLastWillQoS -- wtWebioAn2GraphMQTTLastWillRetain -- wtWebioAn2GraphMQTTLastWillConnectEnable -- wtWebioAn2GraphMQTTLastWillConnectMsg ---------------------------------------------------------------- -- Revison: 1.33 ---------------------------------------------------------------- -- 07.09.2017 New: wtWebioAnxGraphAlarmManagerPort -- wtWebioAnxGraphAlarmMQTT_QoS -- wtWebioAnxGraphAlarmMQTT_Retain ---------------------------------------------------------------- -- Revison: 1.32 ---------------------------------------------------------------- -- 09.11.2016 New: wtWebioAn2GraphMQTT group -- HTTP Request, MQTT Alarm, REST ---------------------------------------------------------------- -- Revison: 1.31 ---------------------------------------------------------------- -- 15.07.2015 Changes for new Navigation (__JB__) ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 22.06.2010 Output with decimal point -- ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 12.01.2009 Webio -- Trap numbering ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 19.01.2007 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 23.12.2005 #57607, WebGraph 2x Thermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioAn2Graph OBJECT IDENTIFIER ::= { wtWebio 43 } -- wtWebioAn2Graph Tree wtWebioAn2GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn2Graph 1 } wtWebioAn2GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn2Graph 2 } wtWebioAn2GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn2Graph 3 } wtWebioAn2GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn2Graph 4 } -- wtWebioAn2GraphConfig Tree wtWebioAn2GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 1 } wtWebioAn2GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 2 } wtWebioAn2GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 3 } -- wtWebioAn2GraphDevice Tree wtWebioAn2GraphText OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 1 } wtWebioAn2GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 2 } wtWebioAn2GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 3 } wtWebioAn2GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 4 } wtWebioAn2GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 5 } wtWebioAn2GraphGraphics OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 6 } -- wtWebioAn2GraphTimeDate Tree wtWebioAn2GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 1 } wtWebioAn2GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 2 } wtWebioAn2GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 3 } -- wtWebioAn2GraphBasic Tree wtWebioAn2GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 1 } wtWebioAn2GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 2 } wtWebioAn2GraphMail OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 3 } wtWebioAn2GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 4 } wtWebioAn2GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 5 } wtWebioAn2GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 6 } wtWebioAn2GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 7 } wtWebioAn2GraphLanguage OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 9 } wtWebioAn2GraphMQTT OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 12 } wtWebioAn2GraphREST OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 13 } -- wtWebioAn2GraphGraphics Tree wtWebioAn2GraphGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 1 } wtWebioAn2GraphGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 2 } wtWebioAn2GraphGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 3 } -- wtWebioAn2GraphTemp Group ------------------------ wtWebioAn2GraphSensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of temperature sensors" ::= { wtWebioAn2GraphTemp 1 } -- Interface Table wtWebioAn2GraphSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebioAn2GraphTemp 2 } wtWebioAn2GraphSensorEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperature sensor numbers." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphSensorTable 1 } WtWebioAn2GraphSensorEntry ::= SEQUENCE { wtWebioAn2GraphSensorNo INTEGER } wtWebioAn2GraphSensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature sensor number." ::= { wtWebioAn2GraphSensorEntry 1 } -- wtWebioAn2GraphTempValue Table wtWebioAn2GraphTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn2GraphTemp 3 } wtWebioAn2GraphTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphTempValueTable 1 } WtWebioAn2GraphTempValueEntry ::= SEQUENCE{ wtWebioAn2GraphTempValue OCTET STRING } wtWebioAn2GraphTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length." ::= { wtWebioAn2GraphTempValueEntry 1 } -- wtWebioAn2GraphBinaryTempValue Table wtWebioAn2GraphBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary temperature values corresponding to the channel numbers." ::= { wtWebioAn2GraphTemp 4 } wtWebioAn2GraphBinaryTempValueEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary temperature values of the sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphBinaryTempValueTable 1 } WtWebioAn2GraphBinaryTempValueEntry ::= SEQUENCE{ wtWebioAn2GraphBinaryTempValue INTEGER } wtWebioAn2GraphBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary temperature value of the sensor in 1/10 degrees Celsius, signed number, 0x4FFF6 indicates an invalid measured value." ::= { wtWebioAn2GraphBinaryTempValueEntry 1 } -- wtWebioAn2GraphTempValuePkt Table wtWebioAn2GraphTempValuePktTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of temperature values corresponding to the channel numbers." ::= { wtWebioAn2GraphTemp 8 } wtWebioAn2GraphTempValuePktEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperatures of the sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphTempValuePktTable 1 } WtWebioAn2GraphTempValuePktEntry ::= SEQUENCE{ wtWebioAn2GraphTempValuePkt OCTET STRING } wtWebioAn2GraphTempValuePkt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperature value of the sensor, ASCII, 5 characters in length, decimal point." ::= { wtWebioAn2GraphTempValuePktEntry 1 } -- wtWebioAn2GraphSessCntrl Group -------------------------------- wtWebioAn2GraphSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebioAn2GraphSessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebioAn2GraphSessCntrl 1 } wtWebioAn2GraphSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphSessCntrl-NoSession(0), wtWebioAn2GraphSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebioAn2GraphSessCntrl 2 } wtWebioAn2GraphSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebioAn2GraphSessCntrl 3 } wtWebioAn2GraphSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebioAn2GraphSessCntrl 4 } wtWebioAn2GraphSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebioAn2GraphSessCntrl 5 } -- wtWebioAn2GraphText Group ------------------------ wtWebioAn2GraphDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebioAn2GraphText 1 } wtWebioAn2GraphDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebioAn2GraphText 2 } wtWebioAn2GraphDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebioAn2GraphText 3 } wtWebioAn2GraphDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebioAn2GraphText 4 } -- wtWebioAn2GraphTimeZone Group ---------------------------- wtWebioAn2GraphTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebioAn2GraphTimeZone 1 } wtWebioAn2GraphTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebioAn2GraphTimeZone 2 } wtWebioAn2GraphTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebioAn2GraphTimeZone 3 } wtWebioAn2GraphStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebioAn2GraphTimeZone 4 } wtWebioAn2GraphStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebioAn2GraphTimeZone 5 } wtWebioAn2GraphStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebioAn2GraphTimeZone 6 } wtWebioAn2GraphStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartMonth-January(1), wtWebioAn2GraphStartMonth-February(2), wtWebioAn2GraphStartMonth-March(3), wtWebioAn2GraphStartMonth-April(4), wtWebioAn2GraphStartMonth-May(5), wtWebioAn2GraphStartMonth-June(6), wtWebioAn2GraphStartMonth-July(7), wtWebioAn2GraphStartMonth-August(8), wtWebioAn2GraphStartMonth-September(9), wtWebioAn2GraphStartMonth-October(10), wtWebioAn2GraphStartMonth-November(11), wtWebioAn2GraphStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebioAn2GraphTimeZone 7 } wtWebioAn2GraphStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartMode-first(1), wtWebioAn2GraphStartMode-second(2), wtWebioAn2GraphStartMode-third(3), wtWebioAn2GraphStartMode-fourth(4), wtWebioAn2GraphStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebioAn2GraphTimeZone 8 } wtWebioAn2GraphStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartWday-Sunday(1), wtWebioAn2GraphStartWday-Monday(2), wtWebioAn2GraphStartWday-Tuesday(3), wtWebioAn2GraphStartWday-Thursday(4), wtWebioAn2GraphStartWday-Wednesday(5), wtWebioAn2GraphStartWday-Friday(6), wtWebioAn2GraphStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebioAn2GraphTimeZone 9 } wtWebioAn2GraphStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn2GraphTimeZone 10 } wtWebioAn2GraphStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebioAn2GraphTimeZone 11 } wtWebioAn2GraphStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopMonth-January(1), wtWebioAn2GraphStopMonth-February(2), wtWebioAn2GraphStopMonth-March(3), wtWebioAn2GraphStopMonth-April(4), wtWebioAn2GraphStopMonth-May(5), wtWebioAn2GraphStopMonth-June(6), wtWebioAn2GraphStopMonth-July(7), wtWebioAn2GraphStopMonth-August(8), wtWebioAn2GraphStopMonth-September(9), wtWebioAn2GraphStopMonth-October(10), wtWebioAn2GraphStopMonth-November(11), wtWebioAn2GraphStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebioAn2GraphTimeZone 12 } wtWebioAn2GraphStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopMode-first(1), wtWebioAn2GraphStopMode-second(2), wtWebioAn2GraphStopMode-third(3), wtWebioAn2GraphStopMode-fourth(4), wtWebioAn2GraphStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebioAn2GraphTimeZone 13 } wtWebioAn2GraphStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopWday-Sunday(1), wtWebioAn2GraphStopWday-Monday(2), wtWebioAn2GraphStopWday-Tuesday(3), wtWebioAn2GraphStopWday-Thursday(4), wtWebioAn2GraphStopWday-Wednesday(5), wtWebioAn2GraphStopWday-Friday(6), wtWebioAn2GraphStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebioAn2GraphTimeZone 14 } wtWebioAn2GraphStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn2GraphTimeZone 15 } wtWebioAn2GraphStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebioAn2GraphTimeZone 16 } -- wtWebioAn2GraphTimeServer Group ---------------------------- wtWebioAn2GraphTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebioAn2GraphTimeServer 1 } wtWebioAn2GraphTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebioAn2GraphTimeServer 2 } wtWebioAn2GraphTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebioAn2GraphTimeServer 3 } wtWebioAn2GraphTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebioAn2GraphTimeServer 4 } -- wtWebioAn2GraphDeviceClock Group ---------------------------- wtWebioAn2GraphClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebioAn2GraphDeviceClock 1 } wtWebioAn2GraphClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebioAn2GraphDeviceClock 2 } wtWebioAn2GraphClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebioAn2GraphDeviceClock 3 } wtWebioAn2GraphClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphClockMonth-January(1), wtWebioAn2GraphClockMonth-February(2), wtWebioAn2GraphClockMonth-March(3), wtWebioAn2GraphClockMonth-April(4), wtWebioAn2GraphClockMonth-May(5), wtWebioAn2GraphClockMonth-June(6), wtWebioAn2GraphClockMonth-July(7), wtWebioAn2GraphClockMonth-August(8), wtWebioAn2GraphClockMonth-September(9), wtWebioAn2GraphClockMonth-October(10), wtWebioAn2GraphClockMonth-November(11), wtWebioAn2GraphClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebioAn2GraphDeviceClock 4 } wtWebioAn2GraphClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebioAn2GraphDeviceClock 5 } -- wtWebioAn2GraphNetwork Group ------------------------ wtWebioAn2GraphIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebioAn2GraphNetwork 1 } wtWebioAn2GraphSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebioAn2GraphNetwork 2 } wtWebioAn2GraphGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebioAn2GraphNetwork 3 } wtWebioAn2GraphDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebioAn2GraphNetwork 4 } wtWebioAn2GraphDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebioAn2GraphNetwork 5 } wtWebioAn2GraphAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disable " ::= { wtWebioAn2GraphNetwork 6 } -- wtWebioAn2GraphHTTP Group -------------------------------- wtWebioAn2GraphStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebioAn2GraphHTTP 1 } wtWebioAn2GraphGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioAn2GraphHTTP 2 } wtWebioAn2GraphHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebioAn2GraphHTTP 3 } -- wtWebioAn2GraphMail Group -------------------------------- wtWebioAn2GraphMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebioAn2GraphMail 1 } wtWebioAn2GraphMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebioAn2GraphMail 2 } wtWebioAn2GraphMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebioAn2GraphMail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebioAn2GraphMail 4 } wtWebioAn2GraphMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebioAn2GraphMail 5 } wtWebioAn2GraphMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebioAn2GraphMail 6 } wtWebioAn2GraphMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebioAn2GraphMail 7 } wtWebioAn2GraphMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebioAn2GraphMail 8 } -- wtWebioAn2GraphSNMP Group -------------------------------- wtWebioAn2GraphSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioAn2GraphSNMP 1 } wtWebioAn2GraphSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioAn2GraphSNMP 2 } wtWebioAn2GraphSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebioAn2GraphSNMP 3 } wtWebioAn2GraphSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebioAn2GraphSNMP 4 } wtWebioAn2GraphSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebioAn2GraphSNMP 5 } wtWebioAn2GraphSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebioAn2GraphSNMP 6 } wtWebioAn2GraphSnmpSystemTrapManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the system trap." ::= { wtWebioAn2GraphSNMP 7 } -- wtWebioAn2GraphUDP Group -------------------------------- wtWebioAn2GraphUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebioAn2GraphUDP 1 } wtWebioAn2GraphUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebioAn2GraphUDP 2 } -- wtWebioAn2GraphSyslog Group -------------------------------- wtWebioAn2GraphSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebioAn2GraphSyslog 1 } wtWebioAn2GraphSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebioAn2GraphSyslog 2 } wtWebioAn2GraphSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebioAn2GraphSyslog 3 } wtWebioAn2GraphSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebioAn2GraphSyslog 4 } -- wtWebioAn2GraphFTP Group -------------------------------- wtWebioAn2GraphFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebioAn2GraphFTP 1 } wtWebioAn2GraphFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebioAn2GraphFTP 2 } wtWebioAn2GraphFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebioAn2GraphFTP 3 } wtWebioAn2GraphFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebioAn2GraphFTP 4 } wtWebioAn2GraphFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebioAn2GraphFTP 5 } wtWebioAn2GraphFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebioAn2GraphFTP 6 } wtWebioAn2GraphFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebioAn2GraphFTP 7 } -- wtWebioAn2GraphLanguage Group -------------------------------- wtWebioAn2GraphLanguageSelect OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Language selection: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 2-7: unused Bit 1 : English Bit 0 : German" ::= { wtWebioAn2GraphLanguage 1 } -- wtWebioAn2GraphMQTT Group -------------------------------- wtWebioAn2GraphMQTTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 7 schaltet MQTT frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0-6: ungenutzt Bit 7 : MQTT enable" ::= { wtWebioAn2GraphMQTT 1 } wtWebioAn2GraphMQTTBrockerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP-address of the MQTT-Server." ::= { wtWebioAn2GraphMQTT 2 } wtWebioAn2GraphMQTTUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login user name." ::= { wtWebioAn2GraphMQTT 3 } wtWebioAn2GraphMQTTPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT login password." ::= { wtWebioAn2GraphMQTT 4 } wtWebioAn2GraphMQTTLocalPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Local port number." ::= { wtWebioAn2GraphMQTT 5 } wtWebioAn2GraphMQTTBrokerServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Server port number." ::= { wtWebioAn2GraphMQTT 6 } wtWebioAn2GraphMQTTInterval OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Ping intervall, if no data has to be send: time in seconds." ::= { wtWebioAn2GraphMQTT 7 } wtWebioAn2GraphMQTTLastWillEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will enable" ::= { wtWebioAn2GraphMQTT 8 } wtWebioAn2GraphMQTTLastWillTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Topic." ::= { wtWebioAn2GraphMQTT 9 } wtWebioAn2GraphMQTTLastWillMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will message." ::= { wtWebioAn2GraphMQTT 10 } wtWebioAn2GraphMQTTLastWillQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish QoS: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebioAn2GraphMQTT 11 } wtWebioAn2GraphMQTTLastWillRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded MQTT Publish Retain properties: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebioAn2GraphMQTT 12 } wtWebioAn2GraphMQTTLastWillConnectEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activate MQTT LastWill Connect message: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : MQTT Last will connect message enable" ::= { wtWebioAn2GraphMQTT 13 } wtWebioAn2GraphMQTTLastWillConnectMsg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Last Will Connect message will be send with the QoS and Retain settings of the LastWill message." ::= { wtWebioAn2GraphMQTT 14 } -- wtWebioAn2GraphREST Group -------------------------------- wtWebioAn2GraphRESTEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates REST : Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : REST enable" ::= { wtWebioAn2GraphREST 1 } wtWebioAn2GraphRESTDigestAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 activates Digest-Authentification: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Digest Auth enable" ::= { wtWebioAn2GraphREST 2 } -- wtWebioAn2GraphDatalogger Group -------------------------------- wtWebioAn2GraphLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphDatalogger-1Min(1), wtWebioAn2GraphDatalogger-5Min(2), wtWebioAn2GraphDatalogger-15Min(3), wtWebioAn2GraphDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebioAn2GraphDatalogger 1 } wtWebioAn2GraphLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphDatalogger 2 } wtWebioAn2GraphDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphDatalogger 3 } -- Graph Sensor Color Table wtWebioAn2GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn2GraphDatalogger 4 } wtWebioAn2GraphSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphSensorColorTable 1 } WtWebioAn2GraphSensorColorEntry ::= SEQUENCE { wtWebioAn2GraphSensorColor OCTET STRING } wtWebioAn2GraphSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn2GraphSensorColorEntry 1 } wtWebioAn2GraphAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebioAn2GraphDatalogger 5 } wtWebioAn2GraphVerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphDatalogger 6 } wtWebioAn2GraphVerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphDatalogger 7 } wtWebioAn2GraphHorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphZoom-25min(1), wtWebioAn2GraphZoom-75min(2), wtWebioAn2GraphZoom-5hrs(3), wtWebioAn2GraphZoom-30hrs(4), wtWebioAn2GraphZoom-5days(5), wtWebioAn2GraphZoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebioAn2GraphDatalogger 8 } -- wtWebioAn2GraphAlarm Group ---------------------------- wtWebioAn2GraphAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebioAn2GraphAlarm 1 } -- Alarm Interface Table wtWebioAn2GraphAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebioAn2GraphAlarm 2 } wtWebioAn2GraphAlarmIfEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebioAn2GraphAlarmNo } ::= { wtWebioAn2GraphAlarmIfTable 1 } WtWebioAn2GraphAlarmIfEntry ::= SEQUENCE { wtWebioAn2GraphAlarmNo INTEGER } wtWebioAn2GraphAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebioAn2GraphAlarmIfEntry 1 } -- Alarm Table wtWebioAn2GraphAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebioAn2GraphAlarm 3 } wtWebioAn2GraphAlarmEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebioAn2GraphAlarmNo } ::= { wtWebioAn2GraphAlarmTable 1 } WtWebioAn2GraphAlarmEntry ::= SEQUENCE { wtWebioAn2GraphAlarmTrigger OCTET STRING, wtWebioAn2GraphAlarmMin OCTET STRING, wtWebioAn2GraphAlarmMax OCTET STRING, wtWebioAn2GraphAlarmHysteresis OCTET STRING, wtWebioAn2GraphAlarmDelay OCTET STRING, wtWebioAn2GraphAlarmInterval OCTET STRING, wtWebioAn2GraphAlarmEnable OCTET STRING, wtWebioAn2GraphAlarmEMailAddr OCTET STRING, wtWebioAn2GraphAlarmMailSubject OCTET STRING, wtWebioAn2GraphAlarmMailText OCTET STRING, wtWebioAn2GraphAlarmManagerIP OCTET STRING, wtWebioAn2GraphAlarmTrapText OCTET STRING, wtWebioAn2GraphAlarmMailOptions OCTET STRING, wtWebioAn2GraphAlarmTcpIpAddr OCTET STRING, wtWebioAn2GraphAlarmTcpPort INTEGER, wtWebioAn2GraphAlarmTcpText OCTET STRING, wtWebioAn2GraphAlarmClearMailSubject OCTET STRING, wtWebioAn2GraphAlarmClearMailText OCTET STRING, wtWebioAn2GraphAlarmClearTrapText OCTET STRING, wtWebioAn2GraphAlarmClearTcpText OCTET STRING, wtWebioAn2GraphAlarmSyslogIpAddr OCTET STRING, wtWebioAn2GraphAlarmSyslogPort INTEGER, wtWebioAn2GraphAlarmSyslogText OCTET STRING, wtWebioAn2GraphAlarmSyslogClearText OCTET STRING, wtWebioAn2GraphAlarmFtpDataPort OCTET STRING, wtWebioAn2GraphAlarmFtpFileName OCTET STRING, wtWebioAn2GraphAlarmFtpText OCTET STRING, wtWebioAn2GraphAlarmFtpClearText OCTET STRING, wtWebioAn2GraphAlarmFtpOption OCTET STRING, wtWebioAn2GraphAlarmTimerCron OCTET STRING, wtWebioAn2GraphAlarmName OCTET STRING, wtWebioAn2GraphAlarmActive OCTET STRING, wtWebioAn2GraphAlarmHttpReqAuthEnable OCTET STRING, wtWebioAn2GraphAlarmHttpReqAuthUser OCTET STRING, wtWebioAn2GraphAlarmHttpReqAuthPassword OCTET STRING, wtWebioAn2GraphAlarmHttpReqSetUrl OCTET STRING, wtWebioAn2GraphAlarmHttpReqClearUrl OCTET STRING, wtWebioAn2GraphAlarmHttpReqServerPort INTEGER, wtWebioAn2GraphAlarmMqttTopicPath OCTET STRING, wtWebioAn2GraphAlarmMqttTopicSetTopic OCTET STRING, wtWebioAn2GraphAlarmMqttTopicClear OCTET STRING, wtWebioAn2GraphAlarmSensorLostSelection OCTET STRING, wtWebioAn2GraphAlarmLimitWindow OCTET STRING, wtWebioAn2GraphAlarmSnmpManagerPort INTEGER, wtWebioAn2GraphAlarmMqttQoS OCTET STRING, wtWebioAn2GraphAlarmMqttRetain OCTET STRING } wtWebioAn2GraphAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphAlarmEntry 1 } wtWebioAn2GraphAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphAlarmEntry 2 } wtWebioAn2GraphAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphAlarmEntry 3 } wtWebioAn2GraphAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphAlarmEntry 4 } wtWebioAn2GraphAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebioAn2GraphAlarmEntry 5 } wtWebioAn2GraphAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebioAn2GraphAlarmEntry 6 } wtWebioAn2GraphAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebioAn2GraphAlarmEntry 7 } wtWebioAn2GraphAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebioAn2GraphAlarmEntry 8 } wtWebioAn2GraphAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebioAn2GraphAlarmEntry 9 } wtWebioAn2GraphAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebioAn2GraphAlarmEntry 10 } wtWebioAn2GraphAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebioAn2GraphAlarmEntry 11 } wtWebioAn2GraphAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn2GraphAlarmEntry 12 } wtWebioAn2GraphAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebioAn2GraphAlarmEntry 13 } wtWebioAn2GraphAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebioAn2GraphAlarmEntry 14 } wtWebioAn2GraphAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebioAn2GraphAlarmEntry 15 } wtWebioAn2GraphAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn2GraphAlarmEntry 16 } wtWebioAn2GraphAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebioAn2GraphAlarmEntry 17 } wtWebioAn2GraphAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..2. provides the current time." ::= { wtWebioAn2GraphAlarmEntry 18 } wtWebioAn2GraphAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebioAn2GraphAlarmEntry 19 } wtWebioAn2GraphAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebioAn2GraphAlarmEntry 20 } wtWebioAn2GraphAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn2GraphAlarmEntry 21 } wtWebioAn2GraphAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebioAn2GraphAlarmEntry 22 } wtWebioAn2GraphAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn2GraphAlarmEntry 23 } wtWebioAn2GraphAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebioAn2GraphAlarmEntry 24 } wtWebioAn2GraphAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebioAn2GraphAlarmEntry 25 } wtWebioAn2GraphAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebioAn2GraphAlarmEntry 26 } wtWebioAn2GraphAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebioAn2GraphAlarmEntry 27 } wtWebioAn2GraphAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebioAn2GraphAlarmEntry 28 } wtWebioAn2GraphAlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebioAn2GraphAlarmEntry 29 } wtWebioAn2GraphAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 text fields space or tab seperated for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebioAn2GraphAlarmEntry 30 } -- __JB__ wtWebioAn2GraphAlarmName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert name" ::= { wtWebioAn2GraphAlarmEntry 39 } -- __JB__ wtWebioAn2GraphAlarmActive OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alert active 1 = ON 0 = OFF" ::= { wtWebioAn2GraphAlarmEntry 40 } wtWebioAn2GraphAlarmHttpReqAuthEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 1-7: unused Bit 0 : HHTP Request Authentication enable" ::= { wtWebioAn2GraphAlarmEntry 61 } wtWebioAn2GraphAlarmHttpReqAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: User" ::= { wtWebioAn2GraphAlarmEntry 62 } wtWebioAn2GraphAlarmHttpReqAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Password" ::= { wtWebioAn2GraphAlarmEntry 63 } wtWebioAn2GraphAlarmHttpReqSetUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Set URL" ::= { wtWebioAn2GraphAlarmEntry 64 } wtWebioAn2GraphAlarmHttpReqClearUrl OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Clear URL" ::= { wtWebioAn2GraphAlarmEntry 65 } wtWebioAn2GraphAlarmHttpReqServerPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Request: Server Port" ::= { wtWebioAn2GraphAlarmEntry 66 } wtWebioAn2GraphAlarmMqttTopicPath OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic path" ::= { wtWebioAn2GraphAlarmEntry 67 } wtWebioAn2GraphAlarmMqttTopicSetTopic OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic SET message" ::= { wtWebioAn2GraphAlarmEntry 68 } wtWebioAn2GraphAlarmMqttTopicClear OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "MQTT Publish: Topic CLEAR message" ::= { wtWebioAn2GraphAlarmEntry 69 } wtWebioAn2GraphAlarmSensorLostSelection OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 2-7: unused Bit 1 : Sensor 1 Bit 0 : Sensor 0 " ::= { wtWebioAn2GraphAlarmEntry 70 } wtWebioAn2GraphAlarmLimitWindow OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If window type is INSIDE the alarm is genereted when the temperature is greater minumum value and lower than maximum value. If window type is OUTSIDE the alarm is generated when the measured value is lower than the minimum value or greater than the maximum value. Binary coded options, select only one option at the same time: OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4, Bit 2-7: unused Bit 1 : inside window Bit 0 : outside window" ::= { wtWebioAn2GraphAlarmEntry 71 } wtWebioAn2GraphAlarmSnmpManagerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the SNMP Manager to which the Webio device should send SNMP traps." ::= { wtWebioAn2GraphAlarmEntry 76 } wtWebioAn2GraphAlarmMqttQoS OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: QoS 0 Bit 1: QoS 1 Bit 2: QoS 2 Bit 3-7:unused" ::= { wtWebioAn2GraphAlarmEntry 77 } wtWebioAn2GraphAlarmMqttRetain OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded value: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : retain enable Bit 1-7 : unused" ::= { wtWebioAn2GraphAlarmEntry 78 } -- wtWebioAn2GraphGraphicsBase Group ---------------------------- wtWebioAn2GraphGraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebioAn2GraphGraphicsBase 1 } wtWebioAn2GraphGraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebioAn2GraphGraphicsBase 2 } wtWebioAn2GraphGraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebioAn2GraphGraphicsBase 3 } wtWebioAn2GraphGraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebioAn2GraphGraphicsBase 4 } wtWebioAn2GraphGraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebioAn2GraphGraphicsBase 5 } wtWebioAn2GraphGraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebioAn2GraphGraphicsBase 6 } -- wtWebioAn2GraphGraphicsSelect Group ---------------------------- wtWebioAn2GraphGraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphGraphicsSelect 1 } wtWebioAn2GraphGraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphGraphicsSelect 2 } -- Graph Sensor Color Table wtWebioAn2GraphSelectSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphSelectSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebioAn2GraphGraphicsSelect 3 } wtWebioAn2GraphSelectSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphSelectSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphSelectSensorColorTable 1 } WtWebioAn2GraphSelectSensorColorEntry ::= SEQUENCE { wtWebioAn2GraphSelectGraphicsSensorColor OCTET STRING, wtWebioAn2GraphSelectGraphicsSelectScale OCTET STRING } wtWebioAn2GraphSelectGraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebioAn2GraphSelectSensorColorEntry 1 } wtWebioAn2GraphSelectGraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unused" ::= { wtWebioAn2GraphSelectSensorColorEntry 2 } -- wtWebioAn2GraphGraphicsScale Group ---------------------------- wtWebioAn2GraphGraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unused" ::= { wtWebioAn2GraphGraphicsScale 1 } wtWebioAn2GraphGraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unused" ::= { wtWebioAn2GraphGraphicsScale 2 } wtWebioAn2GraphGraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebioAn2GraphGraphicsScale 3 } wtWebioAn2GraphGraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebioAn2GraphGraphicsScale 4 } wtWebioAn2GraphGraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Minimum." ::= { wtWebioAn2GraphGraphicsScale 5 } wtWebioAn2GraphGraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Minimum." ::= { wtWebioAn2GraphGraphicsScale 6 } wtWebioAn2GraphGraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebioAn2GraphGraphicsScale 7 } wtWebioAn2GraphGraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebioAn2GraphGraphicsScale 8 } wtWebioAn2GraphGraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Maximum." ::= { wtWebioAn2GraphGraphicsScale 9 } wtWebioAn2GraphGraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Maximum." ::= { wtWebioAn2GraphGraphicsScale 10 } wtWebioAn2GraphGraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebioAn2GraphGraphicsScale 11 } wtWebioAn2GraphGraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebioAn2GraphGraphicsScale 12 } wtWebioAn2GraphGraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Unit." ::= { wtWebioAn2GraphGraphicsScale 13 } wtWebioAn2GraphGraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Unit." ::= { wtWebioAn2GraphGraphicsScale 14 } -- wtWebioAn2GraphPorts Group ---------------------------- -- Table wtWebioAn2GraphPortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebioAn2GraphPorts 1 } wtWebioAn2GraphPortEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphPortTable 1 } WtWebioAn2GraphPortEntry ::= SEQUENCE { wtWebioAn2GraphPortName OCTET STRING, wtWebioAn2GraphPortText OCTET STRING, wtWebioAn2GraphPortOffset1 OCTET STRING, wtWebioAn2GraphPortTemperature1 OCTET STRING, wtWebioAn2GraphPortOffset2 OCTET STRING, wtWebioAn2GraphPortTemperature2 OCTET STRING, wtWebioAn2GraphPortComment OCTET STRING, wtWebioAn2GraphPortSensorSelect OCTET STRING } wtWebioAn2GraphPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebioAn2GraphPortEntry 1 } wtWebioAn2GraphPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebioAn2GraphPortEntry 2 } wtWebioAn2GraphPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 1." ::= { wtWebioAn2GraphPortEntry 3 } wtWebioAn2GraphPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphPortEntry 4 } wtWebioAn2GraphPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at temperature 2." ::= { wtWebioAn2GraphPortEntry 5 } wtWebioAn2GraphPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Reference temperature 1 in degrees with maximum 2 decimal places." ::= { wtWebioAn2GraphPortEntry 6 } wtWebioAn2GraphPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebioAn2GraphPortEntry 7 } wtWebioAn2GraphPortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen für Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt" ::= { wtWebioAn2GraphPortEntry 8 } -- wtWebioAn2GraphManufact Group ---------------------------- wtWebioAn2GraphMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebioAn2GraphManufact 1 } wtWebioAn2GraphMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebioAn2GraphManufact 2 } wtWebioAn2GraphMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebioAn2GraphManufact 3 } wtWebioAn2GraphMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebioAn2GraphManufact 4 } wtWebioAn2GraphMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebioAn2GraphManufact 5 } wtWebioAn2GraphMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebioAn2GraphManufact 6 } -- wtWebioAn2GraphDiag Group ---------------------------- wtWebioAn2GraphDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebioAn2GraphDiag 1 } wtWebioAn2GraphDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebioAn2GraphDiag 2 } wtWebioAn2GraphDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebioAn2GraphDiagErrorMessage. Errors are numbered from 1 to wtWebioAn2GraphDiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebioAn2GraphDiagErrorMessage." ::= { wtWebioAn2GraphDiag 3 } wtWebioAn2GraphDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebioAn2GraphDiagErrorIndex as an index, the appropriate message is available." ::= { wtWebioAn2GraphDiag 4 } wtWebioAn2GraphDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebioAn2GraphDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioAn2GraphAlert1 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 21 wtWebioAn2GraphAlert2 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 22 wtWebioAn2GraphAlert3 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 23 wtWebioAn2GraphAlert4 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 24 wtWebioAn2GraphAlert5 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 25 wtWebioAn2GraphAlert6 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 26 wtWebioAn2GraphAlert7 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 27 wtWebioAn2GraphAlert8 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 28 wtWebioAn2GraphAlert9 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioAn2GraphAlert10 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioAn2GraphAlert11 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 83 wtWebioAn2GraphAlert12 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 84 wtWebioAn2GraphAlert13 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 85 wtWebioAn2GraphAlert14 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 86 wtWebioAn2GraphAlert15 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 87 wtWebioAn2GraphAlert16 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 88 wtWebioAn2GraphAlertDiag TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphDiagErrorIndex, wtWebioAn2GraphDiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Web-Thermograph Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END