-- ***************************************************************** -- raisecom-elps-mib.mib: Raisecom ELPS MIB file -- -- 9 2009, yanguotao -- -- Copyright (c) 1994-2009, 2009 by Raisecom, Inc. -- All rights reserved. -- Modify Record -- 02,20111208,huxiangfeng, ROS00007717,删除节点rcElpsPeerProtectionType 和 rcElpsPeerStatus的默认值 -- 01,20111122,yangkewei, ROS00006692,删除节点rcElpsName的默认值 -- ***************************************************************** RAISECOM-ELPS-MIB DEFINITIONS ::= BEGIN IMPORTS iscomSwitch FROM RAISECOM-BASE-MIB MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Gauge32, NOTIFICATION-TYPE FROM SNMPv2-SMI -- RFC2578 RowStatus,TruthValue FROM SNMPv2-TC -- RFC2579 EnableVar,Vlanset FROM SWITCH-TC; rcElps MODULE-IDENTITY LAST-UPDATED "200909200000Z" ORGANIZATION "Raisecom, Inc." CONTACT-INFO " Raise Systems Postal: Beijing, China Tel: 86-010-82884499 E-mail: yanguotao@raisecom.com" DESCRIPTION "description of ethernet linear protection switching managed object." ::= { iscomSwitch 54} rcElpsBaseGroup OBJECT IDENTIFIER ::= { rcElps 1 } rcElpsFailureDetGroup OBJECT IDENTIFIER ::= { rcElps 2 } -- rcElpsBaseGroup -- ---------------------------------------------------------------- -- rcElpsTrapEnable OBJECT-TYPE SYNTAX EnableVar MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether traps for G.8031 should be generated or not." DEFVAL { disable } ::= { rcElpsBaseGroup 1 } -- rcElpsCfgTable rcElpsCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF RcElpsCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of elps configuration and associated properties." ::= { rcElpsBaseGroup 2} rcElpsCfgEntry OBJECT-TYPE SYNTAX RcElpsCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entry for elps configuration and associated properties." INDEX { rcElpsId } ::= { rcElpsCfgTable 1 } RcElpsCfgEntry ::= SEQUENCE { rcElpsId Unsigned32, rcElpsName OCTET STRING(SIZE (1..32)), rcElpsWorkingPort Integer32, rcElpsWorkingBlockVlanlist Vlanset, rcElpsProtectionPort Integer32, rcElpsProtectionBlockVlanlist Vlanset, rcElpsProtectionTypeAdmin Unsigned32, rcElpsProtectionTypeOper Unsigned32, rcElpsForceSwitch TruthValue, rcElpsManualSwitch TruthValue, rcElpsManualSwitchtoWork TruthValue, rcElpsLockout TruthValue, rcElpsClear TruthValue, rcElpsWtrTimer Unsigned32, rcElpsHoldOffTimer Unsigned32, rcElpsProtocolVlan INTEGER, rcElpsStatus INTEGER, rcElpsDfopStatus INTEGER, rcElpsRowStatus RowStatus } rcElpsId OBJECT-TYPE SYNTAX Unsigned32(1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "An index uniquely identifies a Linear Protection, which ranges from 1~8. This value can't be modified after created." ::= { rcElpsCfgEntry 1 } rcElpsName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..32)) MAX-ACCESS read-create STATUS current DESCRIPTION "Name for the associtaed Linear protection." ::= { rcElpsCfgEntry 2 } rcElpsWorkingPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The port of working transport entity." ::= { rcElpsCfgEntry 3 } rcElpsWorkingBlockVlanlist OBJECT-TYPE SYNTAX Vlanset MAX-ACCESS read-create STATUS current DESCRIPTION "The block Vlan list for working entity." ::= { rcElpsCfgEntry 4 } rcElpsProtectionPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The port of protection.transport entity." ::= { rcElpsCfgEntry 5 } rcElpsProtectionBlockVlanlist OBJECT-TYPE SYNTAX Vlanset MAX-ACCESS read-create STATUS current DESCRIPTION "The block Vlan list for protection entity." ::= { rcElpsCfgEntry 6 } rcElpsProtectionTypeAdmin OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-create STATUS current DESCRIPTION "The protection type configured locally." DEFVAL{ 15 } ::= { rcElpsCfgEntry 7 } rcElpsProtectionTypeOper OBJECT-TYPE SYNTAX Unsigned32 (0..16) MAX-ACCESS read-only STATUS current DESCRIPTION "The protection type coordinated with the far end." ::= { rcElpsCfgEntry 8} rcElpsForceSwitch OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Forces normal traffic signal to be selected from the protection transport entity." DEFVAL{ false } ::= { rcElpsCfgEntry 9 } rcElpsManualSwitch OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "In the absence of a failure of a working or protection transport entity, forces normal traffic signal to be selected from the protection transport entity." DEFVAL{ false } ::= { rcElpsCfgEntry 10 } rcElpsManualSwitchtoWork OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "In the absence of a failure of a working or protection transport entity in non-revertive operation, forces normal traffic signal to be selected from the working transport entity." DEFVAL{ false } ::= { rcElpsCfgEntry 11 } rcElpsLockout OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This command prevents a working signal from being selected from the protection transport entity. This effectively disables the protection group." DEFVAL{ false } ::= { rcElpsCfgEntry 12 } rcElpsClear OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Clears the active near end Lockout of Protection, Forced Switch, Manual Switch, or WTR state." DEFVAL{ false } ::= { rcElpsCfgEntry 13 } rcElpsWtrTimer OBJECT-TYPE SYNTAX Unsigned32 (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "In revertive mode of operation, to prevent frequent operation of the protection switch due to an intermittent defect, a failed working transport entity must become fault-free. After the failed working transport entity meets this criterion, a fixed period of time shall elapse before a normal traffic signal uses it again. This period, called wait-to-restore (WTR) period, may be configured by the operator in 1 minute steps between 5 and 12 minutes; the default value is 5 minutes." DEFVAL { 5 } ::= { rcElpsCfgEntry 14 } rcElpsHoldOffTimer OBJECT-TYPE SYNTAX Unsigned32(0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "When a new defect or more severe defect occurs (new SF), this event will not be reported immediately to protection switching if the provisioned holdoff timer value is non-zero. Instead, the holdoff timer will be started. When the holdoff timer expires, whether a defect still exists on the trail that started the timer will be checked. If one does exist, that defect will be reported to protection switching. Each protection group should have a provisionable holdoff timer. The suggested range of the holdoff timer is 0 to 10 seconds in steps of 100 ms with an accuracy of ±5 ms." DEFVAL { 0 } ::= { rcElpsCfgEntry 15 } rcElpsProtocolVlan OBJECT-TYPE SYNTAX INTEGER(1..4094) MAX-ACCESS read-create STATUS current DESCRIPTION "Protocol vlan for APS packet encapsulation." DEFVAL { 1 } ::= { rcElpsCfgEntry 16 } rcElpsStatus OBJECT-TYPE SYNTAX INTEGER{ nr-w(1), nr-p(2), lo(3), fs(4), sf-w(5), sf-p(6), ms(7), ms-w(8), wtr(9), dnr(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet linear protection status.The default state is No Request (Working/Active Protection/Standby)." DEFVAL { 1 } ::= { rcElpsCfgEntry 17 } rcElpsDfopStatus OBJECT-TYPE SYNTAX INTEGER{ normal(1), dFOP-CM(2), dFOP-PM(3), dFOP-NR(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Elps dFOP status.When the APS protocol is running regularly, the status in normal.If failure of protocol is detected, the status is dFOP-CM,dFOP-PM or dFOP-NR according to the cause of dFOP.The default state is normal." DEFVAL { 1 } ::= { rcElpsCfgEntry 18 } rcElpsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation." ::= { rcElpsCfgEntry 19 } -- ELPS Statistics Table rcElpsStatisticsTable OBJECT-TYPE SYNTAX SEQUENCE OF RcElpsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Statistics Table of Ethernet Linear Protection Switching." ::= { rcElpsBaseGroup 3} rcElpsStatisticsEntry OBJECT-TYPE SYNTAX RcElpsStatisticsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entry for elps statistics information." INDEX { rcElpsId } ::= { rcElpsStatisticsTable 1 } RcElpsStatisticsEntry ::= SEQUENCE { rcElpsStatisticsSwitchCounts Unsigned32, rcElpsStatisticsApsTx Unsigned32, rcElpsStatisticsApsRx Unsigned32, rcElpsStatisticsLastStatusOccur TimeTicks, rcElpsStatisticsLastSwitchOccur TimeTicks, rcElpsStatisticsLastDfop TimeTicks, rcElpsStatisticsClear EnableVar } rcElpsStatisticsSwitchCounts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Counts of switching from working transport entity to protection transport entity or from protection transport entity to working transport entity." ::= { rcElpsStatisticsEntry 1 } rcElpsStatisticsApsTx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "APS packet number sent to the far end." ::= { rcElpsStatisticsEntry 2 } rcElpsStatisticsApsRx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "APS packet number received from the far end." ::= { rcElpsStatisticsEntry 3 } rcElpsStatisticsLastStatusOccur OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time when last status changes." ::= { rcElpsStatisticsEntry 4 } rcElpsStatisticsLastSwitchOccur OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time when last linear protection switching happens." ::= { rcElpsStatisticsEntry 5 } rcElpsStatisticsLastDfop OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Time when last dFOP happens." ::= { rcElpsStatisticsEntry 6 } rcElpsStatisticsClear OBJECT-TYPE SYNTAX EnableVar MAX-ACCESS read-write STATUS current DESCRIPTION "Clear statistics information of linear protection." DEFVAL { disable } ::= { rcElpsStatisticsEntry 7 } -- ELPS Peer Table rcElpsPeerTable OBJECT-TYPE SYNTAX SEQUENCE OF RcElpsPeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Elps information of the far end." ::= { rcElpsBaseGroup 4} rcElpsPeerEntry OBJECT-TYPE SYNTAX RcElpsPeerEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entry for elps information of the far end." INDEX { rcElpsId } ::= { rcElpsPeerTable 1 } RcElpsPeerEntry ::= SEQUENCE { rcElpsPeerProtectionType Unsigned32, rcElpsPeerStatus INTEGER, rcElpsRequestSignal INTEGER, rcElpsBridgedSignal INTEGER } rcElpsPeerProtectionType OBJECT-TYPE SYNTAX Unsigned32(8..15) MAX-ACCESS read-only STATUS current DESCRIPTION "The protection type of the far end." ::= { rcElpsPeerEntry 1 } rcElpsPeerStatus OBJECT-TYPE SYNTAX INTEGER{ nr-w(1), nr-p(2), lo(3), fs(4), sf-w(5), sf-p(6), ms(7), ms-w(8), wtr(9), dnr(10), sd(11), exer(12), rr(13) } MAX-ACCESS read-only STATUS current DESCRIPTION "Ethernet linear protection status of the far end.The default state is No Request (Working/Active Protection/Standby)." ::= { rcElpsPeerEntry 2 } rcElpsRequestSignal OBJECT-TYPE SYNTAX INTEGER{ null(0), normal-traffic-signal(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Request Signal from received APS packet." DEFVAL { 1 } ::= { rcElpsPeerEntry 3 } rcElpsBridgedSignal OBJECT-TYPE SYNTAX INTEGER{ null(0), normal-traffic-signal(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Bridged Signal from received APS packet." DEFVAL { 1 } ::= { rcElpsPeerEntry 4 } -- Notification Definition section rcElpsNotifications OBJECT IDENTIFIER ::= { rcElpsBaseGroup 5 } rcElpsDfopTrap NOTIFICATION-TYPE OBJECTS { rcElpsStatisticsLastDfop } STATUS current DESCRIPTION "When dFOP happens." ::= { rcElpsNotifications 1 } rcElpsDfopClearTrap NOTIFICATION-TYPE OBJECTS { rcElpsStatisticsLastDfop } STATUS current DESCRIPTION "Comes to a new status from dFOP." ::= { rcElpsNotifications 2 } rcElpsSwitchTrap NOTIFICATION-TYPE OBJECTS { rcElpsStatus } STATUS current DESCRIPTION "Linear protection switching happens." ::= { rcElpsNotifications 3 } -- rcElpsFailureDetGroup -- ------------------------------------------------------------------ -- rcElpsFailureDetTable rcElpsFailureDetTable OBJECT-TYPE SYNTAX SEQUENCE OF RcElpsFailureDetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of elps link failure detecton configuration ." ::= { rcElpsFailureDetGroup 1} rcElpsFailureDetEntry OBJECT-TYPE SYNTAX RcElpsFailureDetEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table entry for elps link failure detecton configuration." INDEX { rcElpsId, rcElpsFdLink } ::= { rcElpsFailureDetTable 1 } RcElpsFailureDetEntry ::= SEQUENCE { rcElpsFdLink INTEGER, rcElpsFdType INTEGER, rcElpsFdLinkStatus INTEGER, rcElpsFdSfType INTEGER, rcElpsFdMdName OCTET STRING, rcElpsFdMaName OCTET STRING, rcElpsFdLocalMep INTEGER, rcElpsFdRemoteMep INTEGER, rcElpsMdLevel Integer32 } rcElpsFdLink OBJECT-TYPE SYNTAX INTEGER{ working(1), protection(2) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Linear protection link type, identifies if the link is working entity or protection entity." ::= { rcElpsFailureDetEntry 1 } rcElpsFdType OBJECT-TYPE SYNTAX INTEGER{ physical-link(1), cc(2), both(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The failure detection type for the link." DEFVAL { 1 } ::= { rcElpsFailureDetEntry 2 } rcElpsFdLinkStatus OBJECT-TYPE SYNTAX INTEGER{ ok(1), sf(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link status." ::= { rcElpsFailureDetEntry 3 } rcElpsFdSfType OBJECT-TYPE SYNTAX INTEGER{ none(1), physical-link(2), cc(3), both(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The failure detect types which have triggered SF." ::= { rcElpsFailureDetEntry 4 } rcElpsFdMdName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance Domain name. Each Maintenance Domain has unique name amongst all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each Maintenance Domain." ::= { rcElpsFailureDetEntry 5 } rcElpsFdMaName OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1..13)) MAX-ACCESS read-write STATUS current DESCRIPTION "The Short Maintenance Association name. The type/format of this object is determined by the value of the dot1agCfmMaNetNameType object. This name must be unique within a maintenance domain." ::= { rcElpsFailureDetEntry 6 } rcElpsFdLocalMep OBJECT-TYPE SYNTAX INTEGER(1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Local MEPId of working or protection entity, identifying a specific MEP." ::= { rcElpsFailureDetEntry 7 } rcElpsFdRemoteMep OBJECT-TYPE SYNTAX INTEGER(1..8191) MAX-ACCESS read-write STATUS current DESCRIPTION "Remote MEPId of working or protection entity, identifying a specific MEP." ::= { rcElpsFailureDetEntry 8 } rcElpsMdLevel OBJECT-TYPE SYNTAX Integer32 (0..7) MAX-ACCESS read-write STATUS current DESCRIPTION "The Maintenance Domain Level." ::= { rcElpsFailureDetEntry 9 } END