-- COPYRIGHT NOTICE -- Copyright (c) Radware Ltd. 2009 -- All rights reserved ADMIN-ALTEON-AC-vADC-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Counter32, Gauge32, TimeTicks, IpAddress FROM SNMPv2-SMI DisplayString, PhysAddress FROM SNMPv2-TC virt-admin FROM ALTEON-ROOT-MIB; adminvADC MODULE-IDENTITY LAST-UPDATED "201006170000Z" -- 17 June, 2010 ORGANIZATION "Radware Ltd." CONTACT-INFO "Lobby 1 (Visitors) and Lobby 2 (Deliveries) 575 Corporate Drive Mahwah, NJ 07430 support@radware.com" DESCRIPTION "The MIB module for the Alteon OS AdminContext configuration, statistics and information ." REVISION "201006170000Z" -- 17 June, 2010 DESCRIPTION "Added revision clause for SMIv2 compliance." ::= { virt-admin 1 } adminvADCConfigs OBJECT IDENTIFIER ::= { adminvADC 1 } adminvADCInfo OBJECT IDENTIFIER ::= { adminvADC 2 } adminvADCBoot OBJECT IDENTIFIER ::= { adminvADC 3 } adminvADCStats OBJECT IDENTIFIER ::= { adminvADC 4 } adminvADCOper OBJECT IDENTIFIER ::= { adminvADC 8 } vADCConfig OBJECT IDENTIFIER ::= { adminvADCConfigs 1 } vADCInfo OBJECT IDENTIFIER ::= { adminvADCInfo 1 } vADCBoot OBJECT IDENTIFIER ::= { adminvADCBoot 1 } vADCStat OBJECT IDENTIFIER ::= { adminvADCStats 1 } vADCOper OBJECT IDENTIFIER ::= { adminvADCOper 1 } -- -- #START# vADC Configurations. -- vADCMaxVADCId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum allowed vADC ID. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCConfig 1 } vADCMaxCU OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum allowed Capacity Units, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCConfig 2 } -- vADC current config table for each vADC vADCCurCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCCurCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC configuration." ::= { vADCConfig 3 } vADCCurCfgTableEntry OBJECT-TYPE SYNTAX VADCCurCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC configuration table." INDEX { vADCCurCfgVADCId } ::= { vADCCurCfgTable 1 } VADCCurCfgTableEntry ::= SEQUENCE { vADCCurCfgVADCId INTEGER, vADCCurCfgVlanId OCTET STRING, vADCCurCfgName DisplayString, vADCCurCfgCU INTEGER, vADCCurCfgLimit INTEGER, vADCCurCfgState INTEGER, vADCCurCfgFeatGlobal INTEGER, vADCCurCfgFeatBWM INTEGER, vADCCurCfgFeatITM INTEGER, vADCCurCfgFeatADOS INTEGER, vADCCurCfgFeatLLB INTEGER, vADCCurCfgSslLimit INTEGER, vADCCurCfgCompLimit INTEGER, vADCCurCfgApmLimit INTEGER, vADCCurResetImageVersion DisplayString, vADCCurSyncPeerSwitch INTEGER, vADCCurCfgAwCU INTEGER, vADCCurCfgWafLimit INTEGER, vADCCurCfgAuthLimit INTEGER, vADCCurCfgFastviewLimit INTEGER, vADCCurCfgFastviewCu INTEGER, vADCCurCfgTotalCUs INTEGER, vADCCurCfgPreserveDisk INTEGER, vADCCurCfgFeatLP INTEGER, vADCCurCfgMPCPU INTEGER, vADCCurCfgFeatIPRep INTEGER, vADCCurCfgFeatURLFilter INTEGER } vADCCurCfgVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 1 } vADCCurCfgVlanId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The vlans list for vADCs. The vlans are presented in bitmap format. This string displays vlan number from 1 to 4090. in receiving order: OCTET 1 OCTET 2 ..... xxxxxxxx xxxxxxxx ..... || || |_ vlan 8 || || || ||___ vlan 7 || |____ vlan 6 || . . . ||_________ vlan 1 |__________ Reserved where x : 1 - The represented vlan applied to the vADC. 0 - The represented vlan not applied to the vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 2 } vADCCurCfgName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC name, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 3 } vADCCurCfgCU OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Default vADC Capacity Units, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 4 } vADCCurCfgLimit OBJECT-TYPE SYNTAX INTEGER (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC Throughput value in Mbps, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 5 } vADCCurCfgState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC, Note:This mib is supported only for VX instance of Virtualization" ::= { vADCCurCfgTableEntry 6 } vADCCurCfgFeatGlobal OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of global feature license for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 7 } vADCCurCfgFeatBWM OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of BWM feature license for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 8 } vADCCurCfgFeatITM OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of ITM feature license for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 9 } vADCCurCfgFeatADOS OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of ADoS feature license for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 10 } vADCCurCfgFeatLLB OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of LLB feature license for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 11 } vADCCurCfgSslLimit OBJECT-TYPE SYNTAX INTEGER (0..60000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum SSL throughput Limit allowed for vADC in CPSs. The SSL Throughput value should be in multiples of 10 CPSs blocks. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 12 } vADCCurCfgCompLimit OBJECT-TYPE SYNTAX INTEGER (0..7500) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum compression throughput Limit allowed for vADC in Mbps. The compression Throughput value should be in multiples of 10 Mbps blocks. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 13 } vADCCurResetImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "Image version to use on next reset, Note:This mib is supported only for VX instance of Virtualization" ::= { vADCCurCfgTableEntry 14 } vADCCurSyncPeerSwitch OBJECT-TYPE SYNTAX INTEGER (0..5) MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the Peer Switch (agSysPeerCurCfgIndex), with which the vADC in question is associated (values 1..5). Value 0 means no association. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 15 } vADCCurCfgApmLimit OBJECT-TYPE SYNTAX INTEGER (0..7500) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum APM throughput Limit allowed for vADC in PGpm. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 17 } vADCCurCfgAwCU OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Default vADC WAF Capacity Units. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 18 } vADCCurCfgWafLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum WAF throughput Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 19 } vADCCurCfgAuthLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Authentication Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 20 } vADCCurCfgFastviewLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum Fastview Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 21 } vADCCurCfgFastviewCu OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The Fastview Offline cu allocated for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 22 } vADCCurCfgTotalCUs OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total CUs count allocated to vADC, Fastview and WAF. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 23 } vADCCurCfgPreserveDisk OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable of preserving disk data. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 24 } vADCCurCfgFeatLP OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable LP Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 25 } vADCCurCfgMPCPU OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "MP CPU size. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 26 } vADCCurCfgFeatIPRep OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable IP Reputation Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 27 } vADCCurCfgFeatURLFilter OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable URL Filtering Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgTableEntry 28 } -- vADC new config table for each vADC vADCNewCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCNewCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC configuration." ::= { vADCConfig 4 } vADCNewCfgTableEntry OBJECT-TYPE SYNTAX VADCNewCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC configuration table." INDEX { vADCNewCfgVADCId } ::= { vADCNewCfgTable 1 } VADCNewCfgTableEntry ::= SEQUENCE { vADCNewCfgVADCId INTEGER, vADCNewCfgVlanId OCTET STRING, vADCNewCfgAddVlan INTEGER, vADCNewCfgRemoveVlan INTEGER, vADCNewCfgName DisplayString, vADCNewCfgCU INTEGER, vADCNewCfgLimit INTEGER, vADCNewCfgState INTEGER, vADCNewCfgDelete INTEGER, vADCNewCfgFeatGlobal INTEGER, vADCNewCfgFeatBWM INTEGER, vADCNewCfgFeatITM INTEGER, vADCNewCfgFeatADOS INTEGER, vADCNewCfgFeatLLB INTEGER, vADCNewCfgSslLimit INTEGER, vADCNewCfgCompLimit INTEGER, vADCNewCfgApmLimit INTEGER, vADCNewResetImageVersion DisplayString, vADCNewSyncPeerSwitch INTEGER, vADCNewStatus INTEGER, vADCNewSPcpu INTEGER, vADCNewThroughput INTEGER, vADCNewCfgAwCU INTEGER, vADCNewCfgWafLimit INTEGER, vADCNewCfgAuthLimit INTEGER, vADCNewCfgFastviewLimit INTEGER, vADCNewCfgFastviewCu INTEGER, vADCNewCfgTotalCUs INTEGER, vADCNewCfgPreserveDisk INTEGER, vADCNewCfgFeatLP INTEGER, vADCNewCfgMPCPU INTEGER, vADCNewCfgFeatIPRep INTEGER, vADCNewCfgFeatURLFilter INTEGER } vADCNewCfgVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 1 } vADCNewCfgVlanId OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The vlan list in the vADC in bitmap format. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 2 } vADCNewCfgAddVlan OBJECT-TYPE SYNTAX INTEGER (1..4090) MAX-ACCESS read-create STATUS current DESCRIPTION "The vlan to be added to the specified vADC. A '0' value is returned when read. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 3 } vADCNewCfgRemoveVlan OBJECT-TYPE SYNTAX INTEGER (1..4090) MAX-ACCESS read-create STATUS current DESCRIPTION "The vlan to be removed from the specified vADC. A '0' value is returned when read. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 4 } vADCNewCfgName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-create STATUS current DESCRIPTION "The VADC name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 5 } vADCNewCfgCU OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC Capacity Units. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 6 } vADCNewCfgLimit OBJECT-TYPE SYNTAX INTEGER (0..20000) MAX-ACCESS read-create STATUS current DESCRIPTION "The throughput Limit allowed for vADC in Mbps. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 7 } vADCNewCfgState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a VADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 8 } vADCNewCfgDelete OBJECT-TYPE SYNTAX INTEGER { other(1), delete(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is an action object to create or delete a vADC. other(1) is returned always when read. The following values are writable: delete(2)...to delete a VADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 9 } vADCNewCfgFeatGlobal OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of Global feature license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 10 } vADCNewCfgFeatBWM OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of BWM feature license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 11 } vADCNewCfgFeatITM OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of ITM feature license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 12 } vADCNewCfgFeatADOS OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of ADoS feature license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 13 } vADCNewCfgFeatLLB OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of LLB feature license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 14 } vADCNewCfgSslLimit OBJECT-TYPE SYNTAX INTEGER (0..60000) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum SSL throughput Limit allowed for vADC in CPSs. The SSL Throughput value should be in multiples of 10 CPSs blocks." ::= { vADCNewCfgTableEntry 15 } vADCNewCfgCompLimit OBJECT-TYPE SYNTAX INTEGER (0..7500) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum compression throughput Limit allowed for vADC in Mbps. The compression Throughput value should be in multiples of 10 Mbps blocks." ::= { vADCNewCfgTableEntry 16 } vADCNewResetImageVersion OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "Image version to use on next reset, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 17 } vADCNewSyncPeerSwitch OBJECT-TYPE SYNTAX INTEGER (0..5) MAX-ACCESS read-write STATUS current DESCRIPTION "The ID of the Peer Switch (agSysPeerNewCfgIndex), with which the vADC in question is associated (values 1..5). Value 0 means no association. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 18 } vADCNewCfgApmLimit OBJECT-TYPE SYNTAX INTEGER (0..7500) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum APM throughput Limit allowed for vADC in PgPm. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 20 } vADCNewStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), init(1), running(2), down(3), stopping(4), restarting(5), querying(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "vADC state information. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 21 } vADCNewSPcpu OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of SP CPU usage for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 22 } vADCNewThroughput OBJECT-TYPE SYNTAX INTEGER (1..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "The Maximum throughput allowed for vADC in Mbps. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 23 } vADCNewCfgAwCU OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC WAF Capacity Units. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 24 } vADCNewCfgWafLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum WAF throughput Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 25 } vADCNewCfgAuthLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum Authentication Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 26 } vADCNewCfgFastviewLimit OBJECT-TYPE SYNTAX INTEGER (0..10000) MAX-ACCESS read-create STATUS current DESCRIPTION "The maximum Fastview Limit allowed for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 27 } vADCNewCfgFastviewCu OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "The Fastview Hub cu allocated for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 28 } vADCNewCfgTotalCUs OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Total CUs count allocated to vADC, Fastview and WAF. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 29 } vADCNewCfgPreserveDisk OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable of preserving disk data. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 30 } vADCNewCfgFeatLP OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable LP Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 31 } vADCNewCfgMPCPU OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-create STATUS current DESCRIPTION "MP CPU size. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 32 } vADCNewCfgFeatIPRep OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(0) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable IP Reputation Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 33 } vADCNewCfgFeatURLFilter OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable URL Filtering Module license for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgTableEntry 34 } -- System services current configuration menu for each vADC. vADCCurCfgSysTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCCurCfgSysTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC System services configuration." ::= { vADCConfig 5 } vADCCurCfgSysTableEntry OBJECT-TYPE SYNTAX VADCCurCfgSysTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC System services configuration table." INDEX { vADCCurCfgSysVADCId } ::= { vADCCurCfgSysTable 1 } VADCCurCfgSysTableEntry ::= SEQUENCE { vADCCurCfgSysMmgmtAddr IpAddress, vADCCurCfgSysMmgmtMask IpAddress, vADCCurCfgSysMmgmtGw IpAddress, vADCCurCfgSysMmgmtState INTEGER, vADCCurCfgSysPeerAddr IpAddress, vADCCurCfgSysPeerMask IpAddress, vADCCurCfgSysPeerGw IpAddress, vADCCurCfgSysHttpsState INTEGER, vADCCurCfgSysSshState INTEGER, vADCCurCfgSysHttpState INTEGER, vADCCurCfgSysSnmpState INTEGER, vADCCurCfgSysSyslogState INTEGER, vADCCurCfgSysRadiusState INTEGER, vADCCurCfgSysTacacsState INTEGER, vADCCurCfgSysIdleState INTEGER, vADCCurCfgSysSmtpState INTEGER, vADCCurCfgSyslogDelegation INTEGER, vADCCurCfgRadiusDelegation INTEGER, vADCCurCfgTacacsDelegation INTEGER, vADCCurCfgSmtpDelegation INTEGER, vADCCurCfgSysMmgmtIpv6Addr DisplayString, vADCCurCfgSysMmgmtIpv6PrefixLen INTEGER, vADCCurCfgSysMmgmtIpv6Gateway DisplayString, vADCCurCfgSysPeerIpv6Addr DisplayString, vADCCurCfgSysPeerIpv6PrefixLen INTEGER, vADCCurCfgSysPeerIpv6Gateway DisplayString, vADCCurCfgSysTnetState INTEGER, vADCCurCfgSysHaId INTEGER, vADCCurCfgSysPeerId INTEGER, vADCCurCfgSysVADCId INTEGER, vADCCurCfgIdleDelegation INTEGER, vADCCurCfgSysMmgmtDelegation INTEGER, vADCCurCfgSysPeerName DisplayString, vADCCurCfgSysGlobalLanguage INTEGER } vADCCurCfgSysMmgmtAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services management IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 1 } vADCCurCfgSysMmgmtMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services management IP subnet mask address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 2 } vADCCurCfgSysMmgmtGw OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services management IP gateway address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 3 } vADCCurCfgSysMmgmtState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC management system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 4 } vADCCurCfgSysPeerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services peer IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 5 } vADCCurCfgSysPeerMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services peer IP subnet mask address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 6 } vADCCurCfgSysPeerGw OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services peer IP gateway address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 7 } vADCCurCfgSysHttpsState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC https system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 8 } vADCCurCfgSysSshState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC ssh system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 9 } vADCCurCfgSysHttpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC http system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 10 } vADCCurCfgSysSnmpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC snmp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 11 } vADCCurCfgSysSyslogState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC syslog system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 12 } vADCCurCfgSysRadiusState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC radius system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 13 } vADCCurCfgSysTacacsState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC tacacs system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 14 } vADCCurCfgSysIdleState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC idle system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 15 } vADCCurCfgSysSmtpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a vADC smtp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 16 } vADCCurCfgSyslogDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC syslog system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 17 } vADCCurCfgRadiusDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC radius system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 18 } vADCCurCfgTacacsDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC tacacs system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 19 } vADCCurCfgSmtpDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC smtp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 20 } vADCCurCfgSysMmgmtIpv6Addr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IPV6 address of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 21 } vADCCurCfgSysMmgmtIpv6PrefixLen OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The IPV6 prefix length of the vADC management port. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 22 } vADCCurCfgSysMmgmtIpv6Gateway OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IPV6 Gateway of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 23 } vADCCurCfgSysPeerIpv6Addr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The peer IPV6 Address of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 24 } vADCCurCfgSysPeerIpv6PrefixLen OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services peer IPv6 prefix length. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 25 } vADCCurCfgSysPeerIpv6Gateway OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The Peer IPV6 gateway of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 26 } vADCCurCfgSysTnetState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable vADC Telnet access. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 27} vADCCurCfgSysHaId OBJECT-TYPE SYNTAX INTEGER (0..64) MAX-ACCESS read-only STATUS current DESCRIPTION "HA ID for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 28 } vADCCurCfgSysPeerId OBJECT-TYPE SYNTAX INTEGER (0..28) MAX-ACCESS read-only STATUS current DESCRIPTION "Peer ID for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 29 } vADCCurCfgSysVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 30 } vADCCurCfgIdleDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC idle timeout system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 31 } vADCCurCfgSysMmgmtDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable delegation for vADC management system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 32 } vADCCurCfgSysPeerName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC system services peer Name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 33 } vADCCurCfgSysGlobalLanguage OBJECT-TYPE SYNTAX INTEGER { english(0), chinese(1), korean(2), japanese(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set VX default Web UI display language. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgSysTableEntry 34 } -- System services new configuration menu for each vADC vADCNewCfgSysTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCNewCfgSysTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC System services configuration." ::= { vADCConfig 6 } vADCNewCfgSysTableEntry OBJECT-TYPE SYNTAX VADCNewCfgSysTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC system services configuration table." INDEX { vADCNewCfgSysVADCId } ::= { vADCNewCfgSysTable 1 } VADCNewCfgSysTableEntry ::= SEQUENCE { vADCNewCfgSysMmgmtAddr IpAddress, vADCNewCfgSysMmgmtMask IpAddress, vADCNewCfgSysMmgmtGw IpAddress, vADCNewCfgSysMmgmtState INTEGER, vADCNewCfgSysPeerAddr IpAddress, vADCNewCfgSysPeerMask IpAddress, vADCNewCfgSysPeerGw IpAddress, vADCNewCfgSysHttpsState INTEGER, vADCNewCfgSysSshState INTEGER, vADCNewCfgSysHttpState INTEGER, vADCNewCfgSysSnmpState INTEGER, vADCNewCfgSysSyslogState INTEGER, vADCNewCfgSysRadiusState INTEGER, vADCNewCfgSysTacacsState INTEGER, vADCNewCfgSysIdleState INTEGER, vADCNewCfgSysSmtpState INTEGER, vADCNewCfgSyslogDelegation INTEGER, vADCNewCfgRadiusDelegation INTEGER, vADCNewCfgTacacsDelegation INTEGER, vADCNewCfgSmtpDelegation INTEGER, vADCNewCfgSysMmgmtIpv6Addr DisplayString, vADCNewCfgSysMmgmtIpv6PrefixLen INTEGER, vADCNewCfgSysMmgmtIpv6Gateway DisplayString, vADCNewCfgSysPeerIpv6Addr DisplayString, vADCNewCfgSysPeerIpv6PrefixLen INTEGER, vADCNewCfgSysPeerIpv6Gateway DisplayString, vADCNewCfgSysTnetState INTEGER, vADCNewCfgSysHaId INTEGER, vADCNewCfgSysPeerId INTEGER, vADCNewCfgSysVADCId INTEGER, vADCNewCfgIdleDelegation INTEGER, vADCNewCfgSysMmgmtDelegation INTEGER, vADCNewCfgSysPeerName DisplayString, vADCNewCfgSysGlobalLanguage INTEGER } vADCNewCfgSysMmgmtAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services management IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 1 } vADCNewCfgSysMmgmtMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services management IP subnet mask address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 2 } vADCNewCfgSysMmgmtGw OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services management IP gateway address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 3 } vADCNewCfgSysMmgmtState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC management system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 4 } vADCNewCfgSysPeerAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services peer IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 5 } vADCNewCfgSysPeerMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services peer IP subnet mask address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 6 } vADCNewCfgSysPeerGw OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services peer IP gateway address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 7 } vADCNewCfgSysHttpsState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC https system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 8 } vADCNewCfgSysSshState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC ssh system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 9 } vADCNewCfgSysHttpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC http system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 10 } vADCNewCfgSysSnmpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC snmp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 11 } vADCNewCfgSysSyslogState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC syslog system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 12 } vADCNewCfgSysRadiusState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC radius system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 13 } vADCNewCfgSysTacacsState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC tacacs system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 14 } vADCNewCfgSysIdleState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC idle system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 15 } vADCNewCfgSysSmtpState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable a vADC smtp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 16 } vADCNewCfgSyslogDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC syslog system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 17 } vADCNewCfgRadiusDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC radius system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 18 } vADCNewCfgTacacsDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC tacacs system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 19 } vADCNewCfgSmtpDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC smtp system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 20 } vADCNewCfgSysMmgmtIpv6Addr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The IPV6 address of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 21 } vADCNewCfgSysMmgmtIpv6PrefixLen OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The IPV6 prefix length of the vADC management port. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 22 } vADCNewCfgSysMmgmtIpv6Gateway OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The IPV6 Gateway of the vADC management port. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 23 } vADCNewCfgSysPeerIpv6Addr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The peer IPV6 Address of the vADC system services. Addrvess should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 24 } vADCNewCfgSysPeerIpv6PrefixLen OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services peer IPv6 prefix length. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 25 } vADCNewCfgSysPeerIpv6Gateway OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The Peer IPV6 gateway of the vADC system services. Address should be 16-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 26 } vADCNewCfgSysTnetState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable vADC Telnet access. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 27 } vADCNewCfgSysHaId OBJECT-TYPE SYNTAX INTEGER (0..64) MAX-ACCESS read-create STATUS current DESCRIPTION "HA ID for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 28 } vADCNewCfgSysPeerId OBJECT-TYPE SYNTAX INTEGER (0..256) MAX-ACCESS read-create STATUS current DESCRIPTION "Peer ID for vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 29 } vADCNewCfgSysVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 30 } vADCNewCfgIdleDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC idle timeout system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 31 } vADCNewCfgSysMmgmtDelegation OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable delegation for vADC management system service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 32 } vADCNewCfgSysPeerName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..31)) MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC system services peer Name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 33 } vADCNewCfgSysGlobalLanguage OBJECT-TYPE SYNTAX INTEGER { english(0), chinese(1), korean(2), japanese(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Set vADC default Web UI display language. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgSysTableEntry 34 } -- alloweded network table for vADC current config vADCCurCfgNetTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCCurCfgNetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC configuration." ::= { vADCConfig 7 } vADCCurCfgNetTableEntry OBJECT-TYPE SYNTAX VADCCurCfgNetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the VADC allowed network configuration table." INDEX { vADCCurCfgNetVADCId, vADCCurCfgNetId } ::= { vADCCurCfgNetTable 1 } -- vADCCurCfgNetIPBegin holds the vADCCurCfgNetIPSubnetAddress if the vlan is not shared. VADCCurCfgNetTableEntry ::= SEQUENCE { vADCCurCfgNetId INTEGER, vADCCurCfgNetVlanId INTEGER, vADCCurCfgNetIPver INTEGER, vADCCurCfgNetIPBegin IpAddress, vADCCurCfgNetMask IpAddress, vADCCurCfgNetIPEnd IpAddress, vADCCurCfgNetIPv6Begin DisplayString, vADCCurCfgNetPrefix INTEGER, vADCCurCfgNetIPv6End DisplayString, vADCCurCfgNetVADCId INTEGER } vADCCurCfgNetId OBJECT-TYPE SYNTAX INTEGER (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 1 } vADCCurCfgNetVlanId OBJECT-TYPE SYNTAX INTEGER (1..4096) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network vlan identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 2 } vADCCurCfgNetIPver OBJECT-TYPE SYNTAX INTEGER { ipv4(4), ipv6(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network ip version. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 3 } vADCCurCfgNetIPBegin OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network subnet begining IP address for shared vlan. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 4 } vADCCurCfgNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network subnet address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 5 } vADCCurCfgNetIPEnd OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network subnet end IP address for shared vlan. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 6 } vADCCurCfgNetIPv6Begin OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv6 begining address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 7 } vADCCurCfgNetPrefix OBJECT-TYPE SYNTAX INTEGER(1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The prefix length associated with this IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 8 } vADCCurCfgNetIPv6End OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-only STATUS current DESCRIPTION "The IPv6 end address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 9 } vADCCurCfgNetVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCCurCfgNetTableEntry 10 } -- New config for vADC Allowed network. vADCNewCfgNetTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCNewCfgNetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC allowed network new configuration." ::= { vADCConfig 8 } vADCNewCfgNetTableEntry OBJECT-TYPE SYNTAX VADCNewCfgNetTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the VADC allowed network configuration table." INDEX { vADCNewCfgNetVADCId, vADCNewCfgNetId } ::= { vADCNewCfgNetTable 1 } VADCNewCfgNetTableEntry ::= SEQUENCE { vADCNewCfgNetId INTEGER, vADCNewCfgNetVlanId INTEGER, vADCNewCfgNetIPver INTEGER, vADCNewCfgNetIPBegin IpAddress, vADCNewCfgNetMask IpAddress, vADCNewCfgNetIPEnd IpAddress, vADCNewCfgNetRemId INTEGER, vADCNewCfgNetIPv6Begin DisplayString, vADCNewCfgNetPrefix INTEGER, vADCNewCfgNetIPv6End DisplayString, vADCNewCfgNetVADCId INTEGER } vADCNewCfgNetId OBJECT-TYPE SYNTAX INTEGER (1..1024) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC allowed network identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 1 } vADCNewCfgNetVlanId OBJECT-TYPE SYNTAX INTEGER (1..4096) MAX-ACCESS read-create STATUS current DESCRIPTION "The new vADC allowed network vlan identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 2 } vADCNewCfgNetIPver OBJECT-TYPE SYNTAX INTEGER { ipv4(4), ipv6(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "The new vADC allowed network ip version. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 3 } vADCNewCfgNetIPBegin OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC allowed network subnet begining IP address for shared vlan or subnet IP address for non shared vlan. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 4 } vADCNewCfgNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC allowed network subnet address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 5 } vADCNewCfgNetIPEnd OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The vADC allowed network subnet end IP address for shared vlan. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 6 } vADCNewCfgNetRemId OBJECT-TYPE SYNTAX INTEGER { other(1), delete(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is an action object to create or delete a vADC allowed network. other(1) is returned always when read. The following values are writable: delete(2)...to delete a vADC allowed network, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 7 } vADCNewCfgNetIPv6Begin OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The IPv6 begining address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 8 } vADCNewCfgNetPrefix OBJECT-TYPE SYNTAX INTEGER(1..128) MAX-ACCESS read-create STATUS current DESCRIPTION "The prefix length associated with this IP address. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 9 } vADCNewCfgNetIPv6End OBJECT-TYPE SYNTAX DisplayString (SIZE(0..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "The IPv6 end address of the interface. Address should be 4-byte haxadecimal colon notation. Valid IPv6 address should be in any of the following forms xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx or xxxx::xxxx:xxxx:xxxx:xxxx or ::xxxx, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 10 } vADCNewCfgNetVADCId OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCNewCfgNetTableEntry 11 } -- Configuration Table for vADC Users. vADCAccessUser OBJECT IDENTIFIER ::= { vADCConfig 9 } vADCUResolution OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The minimal increment step between possible CU amounts. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCConfig 10 } vADCCurCfgVadcadvState OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Vadcadv (Advanced Core Allocation) state, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCConfig 11 } vADCAccessUid OBJECT IDENTIFIER ::= { vADCAccessUser 1 } -- Current configuration Table for vADC Users. vADCUserCurCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCUserCurCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "vADC Current User configuration Table." ::= { vADCAccessUid 1 } vADCUserCurCfgTableEntry OBJECT-TYPE SYNTAX VADCUserCurCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the VADC User Table." INDEX { vADCUserCurCfgVADCId, vADCUserCurCfgUId } ::= { vADCUserCurCfgTable 1 } VADCUserCurCfgTableEntry ::= SEQUENCE { vADCUserCurCfgVADCId Integer32, vADCUserCurCfgUId Integer32, vADCUserCurCos INTEGER, vADCUserCurCfgName DisplayString, vADCUserCurCfgAdminPswd DisplayString, vADCUserCurCfgPswd DisplayString, vADCUserCurCfgConfPswd DisplayString, vADCUserCurCfgBackdoor INTEGER, vADCUserCurCfgCrtMng INTEGER, vADCUserCurCfgState INTEGER, vADCUserCurCfgLanguage INTEGER } vADCUserCurCfgVADCId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The VADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 1 } vADCUserCurCfgUId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The User identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 2 } vADCUserCurCos OBJECT-TYPE SYNTAX INTEGER { user(0), l3Oper(1), slboper(2), slbview(3), crtadmin(4), l4oper(5), oper(6), l3admin(7), slbadmin(8), l4admin(9), admin(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "The user class of service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 3 } vADCUserCurCfgName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "The user name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 4 } vADCUserCurCfgAdminPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The character string representing the admin password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 5 } vADCUserCurCfgPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The character string representing the user password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 6 } vADCUserCurCfgConfPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-only STATUS current DESCRIPTION "The character string is used to confirm the user password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 7 } vADCUserCurCfgBackdoor OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable vadc user backdoor access. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 8 } vADCUserCurCfgCrtMng OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable certificate management permissions. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 9 } vADCUserCurCfgState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enable or disable a user. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 10 } vADCUserCurCfgLanguage OBJECT-TYPE SYNTAX INTEGER { english(0), chinese(1), korean(2), japanese(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set Web UI user display language. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserCurCfgTableEntry 11 } -- New configuration Table for vADC Users. vADCUserNewCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCUserNewCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "vADC New User configuration Table." ::= { vADCAccessUid 2 } vADCUserNewCfgTableEntry OBJECT-TYPE SYNTAX VADCUserNewCfgTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the VADC User Table." INDEX { vADCUserNewCfgVADCId, vADCUserNewCfgUId } ::= { vADCUserNewCfgTable 1 } VADCUserNewCfgTableEntry ::= SEQUENCE { vADCUserNewCfgVADCId Integer32, vADCUserNewCfgUId Integer32, vADCUserNewCos INTEGER, vADCUserNewCfgName DisplayString, vADCUserNewCfgAdminPswd DisplayString, vADCUserNewCfgPswd DisplayString, vADCUserNewCfgConfPswd DisplayString, vADCUserNewCfgBackdoor INTEGER, vADCUserNewCfgCrtMng INTEGER, vADCUserNewCfgState INTEGER, vADCUserNewCfgDelete INTEGER, vADCUserNewCfgLanguage INTEGER } vADCUserNewCfgVADCId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 1 } vADCUserNewCfgUId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The User identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 2 } vADCUserNewCos OBJECT-TYPE SYNTAX INTEGER { user(0), l3oper(1), slboper(2), slbview(3), crtadmin(4), l4oper(5), oper(6), l3admin(7), slbadmin(8), l4admin(9), admin(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "The user class of service. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 3 } vADCUserNewCfgName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..8)) MAX-ACCESS read-write STATUS current DESCRIPTION "The user name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 4 } vADCUserNewCfgAdminPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the admin password. Note:This mib is supported only for VX instance of Virtualization. " ::= { vADCUserNewCfgTableEntry 5 } vADCUserNewCfgPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the user password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 6 } vADCUserNewCfgConfPswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string is used to confirm the user password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 7 } vADCUserNewCfgBackdoor OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable vadc user backdoor access. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 8 } vADCUserNewCfgCrtMng OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable certificate management permissions. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 9 } vADCUserNewCfgState OBJECT-TYPE SYNTAX INTEGER { enabled(2), disabled(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable or disable a user. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 10 } vADCUserNewCfgDelete OBJECT-TYPE SYNTAX INTEGER { other(1), delete(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is an action object to create or delete a User. other(1) is returned always when read. The following values are writable: delete(2)...to delete a User, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 11 } vADCUserNewCfgLanguage OBJECT-TYPE SYNTAX INTEGER { english(0), chinese(1), korean(2), japanese(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Set Web UI user display language. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUserNewCfgTableEntry 12 } -- New configuration Table Ends for vADC Users. vADCUsersPswdTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCUsersPswdTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "vADC Users Table." ::= { vADCAccessUser 2 } vADCUsersPswdTableEntry OBJECT-TYPE SYNTAX VADCUsersPswdTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the VADC User Table." INDEX { vADCUsersVADCId } ::= { vADCUsersPswdTable 1 } VADCUsersPswdTableEntry ::= SEQUENCE { vADCUsersVADCId Integer32, vADCAccessUsrPasswd DisplayString, vADCAccessSlbOperPasswd DisplayString, vADCAccessL4OperPasswd DisplayString, vADCAccessOperPasswd DisplayString, vADCAccessSlbAdminPasswd DisplayString, vADCAccessL4AdminPasswd DisplayString, vADCAccessAdminPasswd DisplayString, vADCAccessAdminNewPasswd DisplayString, vADCAccessAdminConfNewPasswd DisplayString, vADCAccessSlbViewerPasswd DisplayString, vADCAccessWsAdminPasswd DisplayString } vADCUsersVADCId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The VADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 1 } vADCAccessUsrPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the user password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 2 } vADCAccessSlbOperPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the SLB operator(slboper) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 3 } vADCAccessL4OperPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the L4 operator(l4oper) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 4 } vADCAccessOperPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the Operator(oper) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 5 } vADCAccessSlbAdminPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the Slb Admin (slbadmin) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 6 } vADCAccessL4AdminPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the L4 Admin(l4admin) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 7 } vADCAccessAdminPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the current Administrator(admin) password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 8 } vADCAccessAdminNewPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the Administrator(admin) New password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 9 } vADCAccessAdminConfNewPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string is used to confirm the Administrator(admin) New password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 10 } vADCAccessSlbViewerPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the SLB viewer password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 11 } vADCAccessWsAdminPasswd OBJECT-TYPE SYNTAX DisplayString (SIZE(0..128)) MAX-ACCESS read-write STATUS current DESCRIPTION "The character string representing the WebApp Security Administrator password. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCUsersPswdTableEntry 12 } vADCUsersSwitch OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Switch RADIUS/TACACS authentication between User and Slbview, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCAccessUser 3 } vADCUsersAdminBackdoor OBJECT-TYPE SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enabled backdoor access for administrator, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCAccessUser 4 } -- Configuration Table Ends for vADC Users. -- -- #END# vADC Configurations. -- -- vADC Info Menu vADCInfoAvailableCU OBJECT-TYPE SYNTAX INTEGER (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The available vADC Capacity Units, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 1 } vADCInfoAvailableThruput OBJECT-TYPE SYNTAX INTEGER (1..80000) MAX-ACCESS read-only STATUS current DESCRIPTION "The available throughput in Mbps, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 2 } vADCInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCInfoTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC information" ::= { vADCInfo 3 } vADCInfoTableEntry OBJECT-TYPE SYNTAX VADCInfoTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular vADC." INDEX { vADCInfoId } ::= { vADCInfoTable 1 } VADCInfoTableEntry ::= SEQUENCE { vADCInfoId INTEGER, vADCInfoName DisplayString, vADCInfoStatus INTEGER, vADCInfoVRRPStatus INTEGER, vADCInfoCU INTEGER, vADCInfoThroughput INTEGER, vADCInfoLimit INTEGER, vADCInfoSPcpu INTEGER, vADCInfoMPcpu INTEGER, vADCInfoCUMbit Integer32, vADCInfoUpTime DisplayString , vADCInfoThrputUtil INTEGER, vADCInfoElasticCoreAllocMPcpuSize INTEGER } vADCInfoId OBJECT-TYPE SYNTAX INTEGER (1..28) MAX-ACCESS read-only STATUS current DESCRIPTION "The VADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 1 } vADCInfoName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..18)) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 2 } vADCInfoStatus OBJECT-TYPE SYNTAX INTEGER { disabled(0), init(1), running(2), down(3), stopping(4), restarting(5), querying(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "vADC state information. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 3 } vADCInfoVRRPStatus OBJECT-TYPE SYNTAX INTEGER { init(1), master(2), backup(3), holdoff(4), off(5), active(6), standby(7), activestar(8), none(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC VRRP state information, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 4 } vADCInfoCU OBJECT-TYPE SYNTAX INTEGER (1..28) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC Capacity Units. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 5 } vADCInfoThroughput OBJECT-TYPE SYNTAX INTEGER (1..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum throughput limit allowed for vADC in Mbps. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 6 } vADCInfoLimit OBJECT-TYPE SYNTAX INTEGER (0..20000) MAX-ACCESS read-only STATUS current DESCRIPTION "The configured throughput limit for vADC in Mbps. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 7 } vADCInfoSPcpu OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of SP CPU usage for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 8 } vADCInfoMPcpu OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The percentage of MP CPU usage for vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 9 } vADCInfoCUMbit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of CU in Mbit. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 10 } vADCInfoUpTime OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC uptime information. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 11 } vADCInfoThrputUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Current throughput of the vADC in Mbps. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 13 } vADCInfoElasticCoreAllocMPcpuSize OBJECT-TYPE SYNTAX INTEGER (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC MP CPU size. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfoTableEntry 14 } vADCInfoConfigChangeTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime at the last vADC configuration change. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 4 } vADCInfoAvailableSSL OBJECT-TYPE SYNTAX INTEGER (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The available SSL in CPS, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 5 } vADCInfoAvailableCompression OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The available compression in Mbps, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 6 } vADCInfoMaxCU OBJECT-TYPE SYNTAX INTEGER (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum vADC Capacity Units, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 7 } vADCInfoMaxThruput OBJECT-TYPE SYNTAX INTEGER (1..80000) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum throughput in Mbps, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 8 } vADCInfoMaxSSL OBJECT-TYPE SYNTAX INTEGER (1..500) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum SSL in CPS, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 9 } vADCInfoMaxCompression OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum compression in Mbps, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 10 } vADCInfoMaxVADCId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum allowed vADC ID. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 11 } vADCInfoMaxApm OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum APM in PgPM, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 12 } vADCInfoAvailableApm OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The available APM in PgPM, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 13 } vADCInfoMinCuFV OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum CU per FV, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 14 } vADCInfoMinCuAw OBJECT-TYPE SYNTAX INTEGER (1..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum CU per AW, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 15 } vADCInfonMaxSslPerCu OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Max SSL CPS Per CU, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 16 } vADCInfonCompPerCu OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Max SSL CPS Per CU, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 17 } vADCInfonCoreAvailable OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Number of free core, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 18 } vADCInfoMinStepCuADC OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum CU step per ADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 19 } vADCInfoMinStepCuFv OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum CU step per FV, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 20 } vADCInfoMinStepCuAw OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum CU step per AW, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCInfo 21 } -- Boot vADC information. vADCBootTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCBootTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC Boot Table." ::= { vADCBoot 1 } vADCBootTableEntry OBJECT-TYPE SYNTAX VADCBootTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular vADC." INDEX { vADCBootVADCId } ::= { vADCBootTable 1 } VADCBootTableEntry ::= SEQUENCE { vADCBootVADCId INTEGER, vADCBootAction INTEGER } vADCBootVADCId OBJECT-TYPE SYNTAX INTEGER (1..28) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCBootTableEntry 1 } vADCBootAction OBJECT-TYPE SYNTAX INTEGER { none(1), reset(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object may contain the following values: none(1) This action does not reboot vADC. Setting this object to none(1) has no effect. reset(2) This action will reboot vADC without apply/save the unapplied/unsaved configuration changes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCBootTableEntry 2 } -- vADC stats Accelaration Resources table for each vADC vADCStatsAccelResourceTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCStatsAccelResourceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC vADCStatsAccelResourceTableEntries." ::= { vADCStat 1 } vADCStatsAccelResourceTableEntry OBJECT-TYPE SYNTAX VADCStatsAccelResourceTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC accelarration resources statistics table." INDEX { vADCIndex } ::= { vADCStatsAccelResourceTable 1 } VADCStatsAccelResourceTableEntry ::= SEQUENCE { vADCIndex INTEGER, vADCName DisplayString, vADCStatsCompLimit INTEGER, vADCStatsCompUtil INTEGER, vADCStatsSSLLimit INTEGER, vADCStatsSSLUtil INTEGER, vADCStatsApmLimit INTEGER, vADCStatsApmUtil INTEGER, vADCStatsWafLimit INTEGER, vADCStatsWafUtil INTEGER, vADCStatsAuthLimit INTEGER, vADCStatsAuthUtil INTEGER, vADCStatsFastviewLimit INTEGER, vADCStatsFastviewUtil INTEGER } vADCIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 1 } vADCName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 2 } vADCStatsCompLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the compression limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 3 } vADCStatsCompUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the compression limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 4 } vADCStatsSSLLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the SSL limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 5 } vADCStatsSSLUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the SSL limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 6 } vADCStatsApmLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the APM limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 7 } vADCStatsApmUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the APM limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 8 } vADCStatsWafLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the WAF limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 9 } vADCStatsWafUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the WAF limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 10 } vADCStatsAuthLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the Authentication limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 11 } vADCStatsAuthUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the Authentication limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 12 } vADCStatsFastviewLimit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " the Fastview limit allocated to vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 13 } vADCStatsFastviewUtil OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "the Fastview limit utilized by vADC, Note:This mib is supported only for VX instance of Virtualization." ::= { vADCStatsAccelResourceTableEntry 14 } -- vADC Memory stats for each vADC vADCMemStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCMemStatsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC vADCMemStatsTableEntries." ::= { vADCStat 2 } vADCMemStatsTableEntry OBJECT-TYPE SYNTAX VADCMemStatsTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC Memory table." INDEX { vADCMemStatsIndex } ::= { vADCMemStatsTable 1 } VADCMemStatsTableEntry ::= SEQUENCE { vADCMemStatsIndex INTEGER, vADCMemStatsName DisplayString, vADCMemStatsCurrentMemory INTEGER, vADCMemStatsHiWaterMark INTEGER, vADCMemStatsMaximum INTEGER } vADCMemStatsIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC index. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsTableEntry 1 } vADCMemStatsName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsTableEntry 2 } vADCMemStatsCurrentMemory OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " The current memory of vADC in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsTableEntry 3 } vADCMemStatsHiWaterMark OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The high watermark of vADC in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsTableEntry 4 } vADCMemStatsMaximum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Allowed Max in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsTableEntry 5 } -- vADC Memory stats for each vADC per SP vADCMemStatsSpTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCMemStatsSpTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC vADCMemStatsSpTableEntries." ::= { vADCStat 3 } vADCMemStatsSpTableEntry OBJECT-TYPE SYNTAX VADCMemStatsSpTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A row in the vADC Memory table." INDEX { vADCMemStatsSpIndex } ::= { vADCMemStatsSpTable 1 } VADCMemStatsSpTableEntry ::= SEQUENCE { vADCMemStatsSpIndex INTEGER, vADCMemStatsSpName DisplayString, vADCMemStatsSpCurrentMemory INTEGER, vADCMemStatsSpHiWaterMark INTEGER, vADCMemStatsSpMaximum INTEGER } vADCMemStatsSpIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC index. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsSpTableEntry 1 } vADCMemStatsSpName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC name. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsSpTableEntry 2 } vADCMemStatsSpCurrentMemory OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION " The current memory of vADC per SP in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsSpTableEntry 3 } vADCMemStatsSpHiWaterMark OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "The high watermark of vADC per SP in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsSpTableEntry 4 } vADCMemStatsSpMaximum OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Allowed Max per sp in KiloBytes. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCMemStatsSpTableEntry 5 } -- Oper vADC menu. vADCOperTable OBJECT-TYPE SYNTAX SEQUENCE OF VADCOperTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of vADC Oper menu." ::= { vADCOper 1 } vADCOperTableEntry OBJECT-TYPE SYNTAX VADCOperTableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Information about a particular vADC." INDEX { vADCOperVADCId } ::= { vADCOperTable 1 } VADCOperTableEntry ::= SEQUENCE { vADCOperVADCId INTEGER, vADCOperAction INTEGER } vADCOperVADCId OBJECT-TYPE SYNTAX INTEGER (1..128) MAX-ACCESS read-only STATUS current DESCRIPTION "The vADC identifier. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCOperTableEntry 1 } vADCOperAction OBJECT-TYPE SYNTAX INTEGER { none(1), reassign(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object may contain the following values: none(1) This action does not reassign vADC. Setting this object to none(1) has no effect. reassign(2) This action will operationally reassign vADC. Note:This mib is supported only for VX instance of Virtualization." ::= { vADCOperTableEntry 2 } -- vADC Memory stats for each vADC per SP END