NETI-COMMON-MIB DEFINITIONS ::= BEGIN -- ------------------------------------------------------------- -- The common OIDs and definitions in the Net Insight -- enterprise MIB -- ------------------------------------------------------------- IMPORTS TEXTUAL-CONVENTION FROM SNMPv2-TC enterprises, MODULE-IDENTITY FROM SNMPv2-SMI; -- ------------------------------------------------------------- -- The enterprise OID -- ------------------------------------------------------------- netinsight MODULE-IDENTITY LAST-UPDATED "201410231300Z" ORGANIZATION "Net Insight AB" CONTACT-INFO "Net Insight AB Box 42093 SE-126 14 Stockholm Sweden Tel +46-8-685 0400 info@netinsight.net" DESCRIPTION "Common definitions for the Net Insight MIB tree. This in the `root' in the Net Insight MIB tree." REVISION "201410231300Z" DESCRIPTION "Added object for new unit Nimbra VA 220: nimbraVA220." REVISION "201404011000Z" DESCRIPTION "Added NETI-TRUNK-MIB." REVISION "201310100900Z" DESCRIPTION "Added object for new unit: nimbra390." REVISION "201306031100Z" DESCRIPTION "Replaced NETI-EVENT-MIB with NETI-EVT-MIB." REVISION "201301301300Z" DESCRIPTION "Added object for new units: nimbraVA210. Added root for new mib NETI-VA-INET-TRANSPORT-MIB. Added object for new unit: nimbra640. Added objects for new boards: nimbra340ModuleTypesAccess8xSDI, nimbra680ModuleTypesSwitch160Gbps, nimbra680ModuleTypesAccess8xVideo, nimbra680ModuleTypesAccess8xASIAES, nimbra680ModuleTypesAccess2x10GbE" REVISION "201209121100Z" DESCRIPTION "Added object for new unit: nimbra240." REVISION "201203220920Z" DESCRIPTION "Added object for new unit: nimbra310." REVISION "201203161300Z" DESCRIPTION "Corrected root object to nimbra230 mibs." REVISION "201103251400Z" DESCRIPTION "Added object for new units: nimbra230 and nimbra320. Added object for new MIB: netiNvMIB" REVISION "201011100800Z" DESCRIPTION "Added object for new unit: nimbra380 Added object for new board: nimbra380ModuleTypesAccess8xGbE" REVISION "201002041500Z" DESCRIPTION "Added objects for new units: nimbra130, nimbra360Gold Added objects for new thermometers: nimbraOneThermometer, nimbra340Thermometer, nimbra680Thermometer Added objects for new boards: nimbraOneModuleTypesAuxGPIO, nimbra340ModuleTypesAuxGPIO, nimbraOneModuleTypesTrunk3xIP, nimbra340ModuleTypesTrunk3xIP, nimbra680ModuleTypesIfTrunk6xIP, nimbraOneModuleTypesTrunkAccess4xDS3E3, nimbra340ModuleTypesTrunkAccess4xDS3E3, nimbra680ModuleTypesAccess8xJPEG2000" REVISION "200812191400Z" DESCRIPTION "Added Nimbra Vision group nimbravision." REVISION "200812121300Z" DESCRIPTION "Updated comments. Corrected date on previous revision (wrong year)." REVISION "200810151200Z" DESCRIPTION "Added object for new board: nimbra680ModuleTypesAccess8x3Gbps" REVISION "200806191000Z" DESCRIPTION "Added objects for new unit: nimbra688" REVISION "200707311500Z" DESCRIPTION "Added objects for new boards: nimbraOneModuleTypesAccess8xAESEBU, nimbra340ModuleTypesAccess8xAESEBU, nimbra680ModuleTypesSwitch80Gbps, nimbra680ModuleTypesAccess8xHDSDI, nimbra680ModuleTypesAccess8xGbE, nimbra680ModuleTypesAccess8xASI, nimbra680ModuleTypesAuxGPIO" REVISION "200701261100Z" DESCRIPTION "Added object for Nimbra 360 trunk." REVISION "200608170830Z" DESCRIPTION "Added objects for Nimbra 340HD: nimbra340HD, nimbra340ModuleTypesAccessHDSDI. Added object for Nimbra 360." REVISION "200512150000Z" DESCRIPTION "Added objects for Nimbra 340. Added new PIU objects for Nimbra One. Removed of obsoleted and never used objects. Reformatted text." REVISION "200303250000Z" DESCRIPTION "Added objects that is used by entPhysicalVendorType in ENTITY-MIB described in RFC2737: nimbraOneModuleTypesDtm622 nimbraOneModuleTypesAccessGigabitEthernet nimbraOneModuleTypesAccessASIRight nimbraOneModuleTypesAccessASILeft" ::= {enterprises 2928} -- ------------------------------------------------------------- -- Textual conventions -- ------------------------------------------------------------- FaultStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Shows the status of a fault that causes an alarm. Each fault should have its own variable and this OID is used as the identifier of the alarm. ok The fault is not present and the alarm is not raised. fault The fault is present and and alarm is raised." SYNTAX INTEGER { ok(1), fault(2) } -- ------------------------------------------------------------- -- Product definitions. The OID's are for identifying the agent -- software and used in sysObjectID in the MIB-II Systems Group. -- ------------------------------------------------------------- netiReg OBJECT IDENTIFIER ::= {netinsight 1} nimbraOne OBJECT IDENTIFIER ::= {netiReg 1} -- deprecated nimbra101 OBJECT IDENTIFIER ::= {netiReg 2} -- deprecated nimbra210 OBJECT IDENTIFIER ::= {netiReg 3} -- deprecated nimbra220 OBJECT IDENTIFIER ::= {netiReg 4} -- deprecated nimbra290 OBJECT IDENTIFIER ::= {netiReg 5} -- deprecated nimbraTwo OBJECT IDENTIFIER ::= {netiReg 6} -- deprecated netiRegGeneric OBJECT IDENTIFIER ::= {netiReg 7} -- for use as root for objects independent of type nimbra291 OBJECT IDENTIFIER ::= {netiReg 8} -- deprecated nimbra340 OBJECT IDENTIFIER ::= {netiReg 9} nimbra680 OBJECT IDENTIFIER ::= {netiReg 10} nimbra340HD OBJECT IDENTIFIER ::= {netiReg 11} nimbra360 OBJECT IDENTIFIER ::= {netiReg 12} nimbra360Gold OBJECT IDENTIFIER ::= {nimbra360 1} -- Is subclass of Nimbra 360 nimbra688 OBJECT IDENTIFIER ::= {netiReg 13} nimbra130 OBJECT IDENTIFIER ::= {netiReg 14} nimbra380 OBJECT IDENTIFIER ::= {netiReg 15} nimbra230 OBJECT IDENTIFIER ::= {netiReg 16} nimbra320 OBJECT IDENTIFIER ::= {netiReg 17} nimbra140 OBJECT IDENTIFIER ::= {netiReg 18} nimbra310 OBJECT IDENTIFIER ::= {netiReg 19} nimbra240 OBJECT IDENTIFIER ::= {netiReg 20} nimbra640 OBJECT IDENTIFIER ::= {netiReg 21} nimbraVA210 OBJECT IDENTIFIER ::= {netiReg 22} nimbraVA210FV OBJECT IDENTIFIER ::= {nimbraVA210 1} nimbraVA210DCV1 OBJECT IDENTIFIER ::= {nimbraVA210 2} nimbraVA210DCV2 OBJECT IDENTIFIER ::= {nimbraVA210 3} nimbra390 OBJECT IDENTIFIER ::= {netiReg 23} nimbraVA220 OBJECT IDENTIFIER ::= {netiReg 25} -- ------------------------------------------------------------- -- Product definitions. The OID's are for identifying the -- type of physical entity and is used in entPhysicalVendorType -- in the ENTITY-MIB Physical Table. -- ------------------------------------------------------------- -- -- NimbraOne -- (obsoleted since GX4.12.0) -- nimbraOneChassisTypes OBJECT IDENTIFIER ::= {nimbraOne 1} nimbraOneBaseUnit OBJECT IDENTIFIER ::= {nimbraOneChassisTypes 1} nimbraOneBackplaneTypes OBJECT IDENTIFIER ::= {nimbraOne 2} nimbraOneBackplane OBJECT IDENTIFIER ::= {nimbraOneBackplaneTypes 1} nimbraOneContainerTypes OBJECT IDENTIFIER ::= {nimbraOne 3} nimbraOneSlot OBJECT IDENTIFIER ::= {nimbraOneContainerTypes 1} nimbraOnePowerSupplyTypes OBJECT IDENTIFIER ::= {nimbraOne 4} nimbraOnePowerSupply OBJECT IDENTIFIER ::= {nimbraOnePowerSupplyTypes 1} nimbraOneFanTypes OBJECT IDENTIFIER ::= {nimbraOne 5} nimbraOneFan OBJECT IDENTIFIER ::= {nimbraOneFanTypes 1} nimbraOneModuleTypes OBJECT IDENTIFIER ::= {nimbraOne 6} -- Plug-In Units -- Management modules (Node Controller) nimbraOneModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 1} nimbraOneModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbraOneModuleTypesMgmt 1} -- Trunk modules nimbraOneModuleTypesDtm OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 2} -- (obsoleted since GX3.3.2) nimbraOneModuleTypesDtm850ShortHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 1} -- MAU850 nimbraOneModuleTypesDtm850ShortHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 2} -- MAU850 nimbraOneModuleTypesDtm850LongHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 3} -- MAU850 nimbraOneModuleTypesDtm850LongHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 4} -- MAU850 nimbraOneModuleTypesDtm1000ShortHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 5} -- MAU1000 nimbraOneModuleTypesDtm1000ShortHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 6} -- MAU1000 nimbraOneModuleTypesDtm1000LongHaulRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 7} -- MAU1000 nimbraOneModuleTypesDtm1000LongHaulLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 8} -- MAU1000 nimbraOneModuleTypesDtm150Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 9} -- MAU150 nimbraOneModuleTypesDtm150Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 10} -- MAU150 nimbraOneModuleTypesDtm622 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 11} -- MAU600 -- (obsoleted since GX4.12.0) nimbraOneModuleTypesTrunk1Gbps OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 12} -- MAU1000 nimbraOneModuleTypesTrunkDS3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 13} -- MAU50 nimbraOneModuleTypesTrunkOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 14} -- MAU150 nimbraOneModuleTypesTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 15} -- MAU155 nimbraOneModuleTypesTrunkOC12 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 16} -- MAU600 nimbraOneModuleTypesTrunkOC48 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 17} -- MAU2500 nimbraOneModuleTypesTrunk3xIP OBJECT IDENTIFIER ::= {nimbraOneModuleTypesDtm 18} -- IP/Ethernet -- Access modules nimbraOneModuleTypesAccess OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 3} -- (obsoleted since GX3.2.2) nimbraOneModuleTypesAccessE1Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 1} -- E1 nimbraOneModuleTypesAccessE1Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 2} -- E1 nimbraOneModuleTypesAccessT1Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 3} -- T1 nimbraOneModuleTypesAccessT1Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 4} -- T1 nimbraOneModuleTypesAccessVideo270Right OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 5} -- SDI nimbraOneModuleTypesAccessVideo270Left OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 6} -- SDI nimbraOneModuleTypesAccessEthernet8pRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 7} -- FEC nimbraOneModuleTypesAccessEthernet8pLeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 8} -- FEC nimbraOneModuleTypesAccessGigabitEthernet OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 9} -- GEC nimbraOneModuleTypesAccessASIRight OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 11} -- ASI nimbraOneModuleTypesAccessASILeft OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 12} -- ASI -- (obsoleted since GX4.12.0) nimbraOneModuleTypesAccessGbE OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 13} -- GEC nimbraOneModuleTypesAccess8xEth OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 14} -- FEC nimbraOneModuleTypesAccessASI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 15} -- ASI nimbraOneModuleTypesAccessSDI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 16} -- SDI nimbraOneModuleTypesAccess4xOC3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 17} -- SAC155 nimbraOneModuleTypesAccessE1 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 18} -- T1 nimbraOneModuleTypesAccessT1 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 19} -- E1 nimbraOneModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 20} -- 8x ASI nimbraOneModuleTypesAccess8xAESEBU OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAccess 21} -- 8x AES/EBU -- Trunk and Access modules nimbraOneModuleTypesTrunkAccess OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 4} nimbraOneModuleTypesTrunkAccess4xDS3E3 OBJECT IDENTIFIER ::= {nimbraOneModuleTypesTrunkAccess 1} -- 4x DS3/E3 -- Auxillary Modules nimbraOneModuleTypesAux OBJECT IDENTIFIER ::= {nimbraOneModuleTypes 5} nimbraOneModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbraOneModuleTypesAux 1} -- GPIO Alarm Module -- Thermometers nimbraOneThermometerTypes OBJECT IDENTIFIER ::= {nimbraOne 7} nimbraOneThermometer OBJECT IDENTIFIER ::= {nimbraOneThermometerTypes 1} -- -- Nimbra290 -- (obsoleted since GX3.2.8) -- nimbra290ChassisTypes OBJECT IDENTIFIER ::= {nimbra290 1} nimbra290BaseUnit OBJECT IDENTIFIER ::= {nimbra290ChassisTypes 1} nimbra290PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra290 2} nimbra290PowerUnit OBJECT IDENTIFIER ::= {nimbra290PowerSupplyTypes 1} nimbra290FanTypes OBJECT IDENTIFIER ::= {nimbra290 3} nimbra290Fan OBJECT IDENTIFIER ::= {nimbra290FanTypes 1} -- -- Nimbra340 -- nimbra340ChassisTypes OBJECT IDENTIFIER ::= {nimbra340 1} nimbra340ContainerTypes OBJECT IDENTIFIER ::= {nimbra340 3} nimbra340PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra340 4} nimbra340FanTypes OBJECT IDENTIFIER ::= {nimbra340 5} nimbra340ModuleTypes OBJECT IDENTIFIER ::= {nimbra340 6} -- Plug-In Units -- Management modules (Built-in Node Controller) nimbra340ModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 1} nimbra340ModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbra340ModuleTypesMgmt 1} -- Trunk modules for N340, N360 and N380 nimbra340ModuleTypesDtm OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 2} nimbra340ModuleTypesTrunk1Gbps OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 1} -- MAU1000 nimbra340ModuleTypesTrunkDS3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 2} -- MAU50 nimbra340ModuleTypesTrunkOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 3} -- MAU150 nimbra340ModuleTypesTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 4} -- MAU155 nimbra340ModuleTypesTrunkOC12 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 5} -- MAU600 nimbra340ModuleTypesTrunkOC48 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 6} -- MAU2500 nimbra340ModuleTypesTrunk3xIP OBJECT IDENTIFIER ::= {nimbra340ModuleTypesDtm 7} -- 3xIP/Ethernet -- Access modules for N340, N360 and N380 nimbra340ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 3} nimbra340ModuleTypesAccessGbE OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 1} -- GEC nimbra340ModuleTypesAccess8xEth OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 2} -- FEC nimbra340ModuleTypesAccessASI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 3} -- ASI nimbra340ModuleTypesAccessSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 4} -- SD SDI nimbra340ModuleTypesAccess4xOC3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 5} -- SAC155 nimbra340ModuleTypesAccessE1 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 6} -- T1 nimbra340ModuleTypesAccessT1 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 7} -- E1 nimbra340ModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 8} -- 8x ASI nimbra340ModuleTypesAccessHDSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 9} -- HD SDI nimbra340ModuleTypesAccess8xAESEBU OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 10} -- 8x AES/EBU nimbra340ModuleTypesAccess8xSDI OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAccess 11} -- 8x SDI -- Built in modules for N340, N360 and N380. These modules are not -- plug-in units, but are still modeled as such. Becase the N340, N360 -- and N380 are all variants that differs only on the set of these -- fixed built-in modules, these fixed modules are grouped together -- with the N340 modules. -- Trunk modules nimbra360ModuleTypesDtm OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 4} nimbra360ModuleTypesTrunkFunction OBJECT IDENTIFIER ::= {nimbra360ModuleTypesDtm 1} -- STM module -- Auxillary Modules nimbra340ModuleTypesAux OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 5} nimbra340ModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbra340ModuleTypesAux 1} -- GPIO Alarm Module -- Trunk and Access modules nimbra340ModuleTypesTrunkAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 6} nimbra340ModuleTypesTrunkAccess4xDS3E3 OBJECT IDENTIFIER ::= {nimbra340ModuleTypesTrunkAccess 1} -- 4x DS3/E3 -- Access Modules built-in on N380 nimbra380ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra340ModuleTypes 7 } nimbra380ModuleTypesAccess8xGbE OBJECT IDENTIFIER ::= {nimbra380ModuleTypesAccess 1} -- Thermometers built-in nimbra340ThermometerTypes OBJECT IDENTIFIER ::= {nimbra340 7} nimbra340Thermometer OBJECT IDENTIFIER ::= {nimbra340ThermometerTypes 1} -- -- Nimbra 680 -- nimbra680ChassisTypes OBJECT IDENTIFIER ::= {nimbra680 1} nimbra680ContainerTypes OBJECT IDENTIFIER ::= {nimbra680 3} nimbra680PowerSupplyTypes OBJECT IDENTIFIER ::= {nimbra680 4} nimbra680FanTypes OBJECT IDENTIFIER ::= {nimbra680 5} nimbra680ModuleTypes OBJECT IDENTIFIER ::= {nimbra680 6} -- Plug-In Units -- Power nimbra680PowerSupplyTypesPCU OBJECT IDENTIFIER ::= {nimbra680PowerSupplyTypes 1} -- DC/DC converter nimbra680PowerSupplyTypesPSU OBJECT IDENTIFIER ::= {nimbra680PowerSupplyTypes 2} -- Rectifier -- Fans nimbra680FanTypesFan OBJECT IDENTIFIER ::= {nimbra680FanTypes 1} -- Management modules nimbra680ModuleTypesMgmt OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 1} nimbra680ModuleTypesMgmtControlModule OBJECT IDENTIFIER ::= {nimbra680ModuleTypesMgmt 1} -- Interface modules nimbra680ModuleTypesIf OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 2} nimbra680ModuleTypesIfTrunk4xOC3 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 1} nimbra680ModuleTypesIfTrunk4xOC12 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 2} nimbra680ModuleTypesIfTrunk2xOC48 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 3} nimbra680ModuleTypesIfTrunk4xOC48 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 4} nimbra680ModuleTypesIfTrunkOC192 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 5} nimbra680ModuleTypesIfTrunk6xIP OBJECT IDENTIFIER ::= {nimbra680ModuleTypesIf 6} -- Switch modules nimbra680ModuleTypesSwitch OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 3} nimbra680ModuleTypesSwitch40Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 1} nimbra680ModuleTypesSwitch80Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 2} nimbra680ModuleTypesSwitch160Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesSwitch 3} -- Access Modules nimbra680ModuleTypesAccess OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 4} nimbra680ModuleTypesAccess8xHDSDI OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 1} -- 8x HD/SD SDI nimbra680ModuleTypesAccess8xGbE OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 2} -- 8x GbE nimbra680ModuleTypesAccess8xASI OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 3} -- 8x ASI nimbra680ModuleTypesAccess8x3Gbps OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 4} -- 8x 3G nimbra680ModuleTypesAccess8xJPEG2000 OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 5} -- 8x JPEG2000 nimbra680ModuleTypesAccess8xVideo OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 6} -- 8x Video nimbra680ModuleTypesAccess8xASIAES OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 7} -- 8x ASI/AES nimbra680ModuleTypesAccess2x10GbE OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAccess 8} -- 2x 10GbE -- Auxillary Modules nimbra680ModuleTypesAux OBJECT IDENTIFIER ::= {nimbra680ModuleTypes 5} nimbra680ModuleTypesAuxGPIO OBJECT IDENTIFIER ::= {nimbra680ModuleTypesAux 1} -- GPIO Alarm Module -- Thermometers nimbra680ThermometerTypes OBJECT IDENTIFIER ::= {nimbra680 7} nimbra680Thermometer OBJECT IDENTIFIER ::= {nimbra680ThermometerTypes 1} -- ------------------------------------------------------------- -- The MIB tree -- ------------------------------------------------------------- -- Mib tree for generic MIBs. Objects and events not associated -- with a specific product. netiGeneric OBJECT IDENTIFIER ::= {netinsight 2} -- MIBs assigned in the generic subtree: -- NETI-EVENT-MIB netiEventMIB ::= { netiGeneric 1 } -- NETI-ETH-MIB netiEthMIB ::= { netiGeneric 2 } -- NETI-TRUNK-MIB netiTrunkMIB ::= { netiGeneric 3 } -- NETI-VA-INET-TRANSPORT-MIB netiVaInetTrspMIB ::= { netiGeneric 4 } -- Product specific mibs. Objects and events associated with a -- specific product. netiProducts OBJECT IDENTIFIER ::= {netinsight 3} nimbravision OBJECT IDENTIFIER ::= {netiProducts 1} -- MIBs assigned in the nimbravision subtree -- NETI-NV-ALARM-MIB netiNvAlarmMIB ::= { nimbravision 1 } -- NETI-NV-MIB netiNvMIB ::= { nimbravision 2 } prodNimbra230 OBJECT IDENTIFIER ::= {netiProducts 2} -- nimbra230MIB ::= { netiProducts 2 } -- nimbra140MIB ::= { netiProducts 3 } -- Agent implementation profiles/capabilities netiCaps OBJECT IDENTIFIER ::= {netinsight 4} -- Requirement specifications netiReqs OBJECT IDENTIFIER ::= {netinsight 5} -- ------------------------------------------------------------- -- Experimental MIBs, initially for objects and events -- under development. The structure is the same as for -- netiGeneric above. -- ------------------------------------------------------------- -- MIBs assigned in the experimental generic subtree: -- NETI-ACCOUNTING-MIB ::= { netiExperimentalGeneric 1 } - deprecated -- NETI-ALARM-MIB netiAlarmMIB ::= { netiExperimentalGeneric 2 } - deprecated -- NETI-DLE-MIB netiDLEMIB ::= { netiExperimentalGeneric 3 } - deprecated -- NETI-DTM-MIB netiDTMMIB ::= { netiExperimentalGeneric 4 } -- NETI-TUNNEL-MIB netiTunnelMIB ::= { netiExperimentalGeneric 5 } - deprecated -- NETI-SYSTEM-MIB netiSystemMIB ::= { netiExperimentalGeneric 6 } - deprecated -- NETI-CONFIG-MIB netiConfigMIB ::= { netiExperimentalGeneric 7 } -- NETI-ALARM-MIB2 netiAlarmMIB2 ::= { netiExperimentalGeneric 8 } - deprecated -- NETI-IPOD-MIB netiIpodMIB ::= { netiExperimentalGeneric 9 } - deprecated -- NETI-ENTITY-MIB netiEntityMIB ::= { netiExperimentalGeneric 10 } - deprecated -- NETI-ETS-MIB netiEtsMIB ::= { netiExperimentalGeneric 11 } - deprecated -- NETI-ETHCONF-MIB netiEthConfMIB ::= { netiExperimentalGeneric 12 } - deprecated -- NETI-PACKW-MIB netiPackWMIB ::= { netiExperimentalGeneric 13 } - deprecated -- NETI-CHMGR-MIB netiChmgrMIB ::= { netiExperimentalGeneric 14 } -- NETI-DLT-MIB netiDltMIB ::= { netiExperimentalGeneric 15 } - deprecated -- NETI-ITS-MIB netiItsMIB ::= { netiExperimentalGeneric 16 } -- NETI-PM-MIB netiPMMIB ::= { netiExperimentalGeneric 17 } netiExperimental OBJECT IDENTIFIER ::= {netinsight 6} netiExperimentalReg OBJECT IDENTIFIER ::= {netiExperimental 1} netiExperimentalGeneric OBJECT IDENTIFIER ::= {netiExperimental 2} netiExperimentalProducts OBJECT IDENTIFIER ::= {netiExperimental 3} netiExperimentalCaps OBJECT IDENTIFIER ::= {netiExperimental 4} netiExperimentalReqs OBJECT IDENTIFIER ::= {netiExperimental 5} END