-- Box Services MIB overview: -- Box Services MIB falls under fastPath MIB node of the private subtree. NETAPP-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN -- Broadcom Corporation FASTPATH Box Services MIB -- Copyright Broadcom Corporation(2004-2008) All rights reserved. -- This SNMP Management Information Specification -- embodies Broadcom Corporation's confidential and proprietary -- intellectual property. Broadcom Corporation retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Broadcom Corporation -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION FROM SNMPv2-TC DisplayString FROM RFC1213-MIB fastPath FROM NETAPP-REF-MIB; fastPathBoxServices MODULE-IDENTITY LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT ORGANIZATION "Broadcom Corporation" CONTACT-INFO " Customer Support Postal: Broadcom Corporation 1030 Swabia Court Suite 400 Durham, NC 27703 Tel: +1 919 865 2700" DESCRIPTION "The Broadcom Private MIB for FASTPATH Box Services Feature." -- Revision history. REVISION "201101260000Z" -- 26 Jan 2011 12:00:00 GMT DESCRIPTION "Postal address updated." REVISION "200802220000Z" -- 22 Feb 2008 12:00:00 GMT DESCRIPTION "Broadcom branding related changes." ::= { fastPath 43 } BoxsTemperatureStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The temperature state" SYNTAX INTEGER { low(0), normal(1), warning(2), critical(3), shutdown(4), notpresent(5), notoperational(6) } --************************************************************************************** -- boxServicesGroup -- -- This group provides configuration and status of the Box Services -- feature. -- --************************************************************************************** boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 } --************************************************************************************** -- Some scalars boxServicesNormalTempRangeMin OBJECT-TYPE SYNTAX Integer32 (-100..100) MAX-ACCESS read-only STATUS current DESCRIPTION " Lower boundary of normal temperature range." ::= { boxServicesGroup 1 } boxServicesNormalTempRangeMax OBJECT-TYPE SYNTAX Integer32 (-100..100) MAX-ACCESS read-only STATUS current DESCRIPTION " Upper boundary of normal temperature range." ::= { boxServicesGroup 2 } boxServicesTemperatureTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range" DEFVAL { enable } ::= { boxServicesGroup 3 } boxServicesPSMStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Power Supply Module state change trap." DEFVAL { enable } ::= { boxServicesGroup 4 } boxServicesFanStateTrapEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Enable or disable Fan state change trap." DEFVAL { enable } ::= { boxServicesGroup 5 } boxsPwrUsageHistoryUnitSampleInterval OBJECT-TYPE SYNTAX INTEGER (30..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Interval at which power consumption data needs to be collected." ::= { boxServicesGroup 10 } boxsPwrUsageHistoryUnitMaxSamples OBJECT-TYPE SYNTAX INTEGER (1..168) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of samples to keep." ::= { boxServicesGroup 11 } boxServicesThermalShutdownSensor OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The number of the sensor which initiated thermal shutdown." ::= { boxServicesGroup 13 } boxServicesThermalShutdownTemperature OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The temperature of the sensor which initiated thermal shutdown." ::= { boxServicesGroup 14 } --************************************************************************************** -- boxServicesFans boxServicesFansTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan" ::= { boxServicesGroup 6 } boxServicesFansEntry OBJECT-TYPE SYNTAX BoxServicesFansEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Fan Entry" INDEX { boxServicesFansIndex } ::= { boxServicesFansTable 1 } BoxServicesFansEntry ::= SEQUENCE { boxServicesFansIndex Integer32, boxServicesFanItemType INTEGER, boxServicesFanItemState INTEGER, boxServicesFanSpeed Integer32, boxServicesFanDutyLevel Integer32 } boxServicesFansIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of fan table entry" ::= { boxServicesFansEntry 1 } boxServicesFanItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of fan" ::= { boxServicesFansEntry 2 } boxServicesFanItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3), nopower(4), powering(5), notpowering(6), incompatible(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of fan" ::= { boxServicesFansEntry 3 } boxServicesFanSpeed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The speed of fan" ::= { boxServicesFansEntry 4} boxServicesFanDutyLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The duty level of fan, in percents" ::= { boxServicesFansEntry 5} --************************************************************************************** -- boxServicesPowSupplies boxServicesPowSuppliesTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power supply" ::= { boxServicesGroup 7 } boxServicesPowSuppliesEntry OBJECT-TYPE SYNTAX BoxServicesPowSuppliesEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Power Supply Entry" INDEX { boxServicesPowSupplyIndex } ::= { boxServicesPowSuppliesTable 1 } BoxServicesPowSuppliesEntry ::= SEQUENCE { boxServicesPowSupplyIndex Integer32, boxServicesPowSupplyItemType INTEGER, boxServicesPowSupplyItemState INTEGER } boxServicesPowSupplyIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of power supply table entry" ::= { boxServicesPowSuppliesEntry 1 } boxServicesPowSupplyItemType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of power supply" ::= { boxServicesPowSuppliesEntry 2 } boxServicesPowSupplyItemState OBJECT-TYPE SYNTAX INTEGER { notpresent(1), operational(2), failed(3), nopower(4), powering(5), notpowering(6), incompatible(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of power supply." ::= { boxServicesPowSuppliesEntry 3 } -- Box Services Unit Power Usage History table boxsUnitPwrUsageHistoryTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxsUnitPwrUsageHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table providing configuration and status of Power Usage History feature" ::= { boxServicesGroup 9 } boxsUnitPwrUsageHistoryEntry OBJECT-TYPE SYNTAX BoxsUnitPwrUsageHistoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Usage History Table for a Unit." INDEX { boxsPwrUsageHistoryUnitIndex, boxsPwrUsageHistoryUnitSampleIndex } ::= { boxsUnitPwrUsageHistoryTable 1 } BoxsUnitPwrUsageHistoryEntry::= SEQUENCE { boxsPwrUsageHistoryUnitIndex INTEGER, boxsPwrUsageHistoryUnitSampleIndex INTEGER, boxsPwrUsageHistoryUnitSampleTime DisplayString, boxsPwrUsageHistoryUnitPowerConsumption INTEGER, boxsPwrUsageHistoryStackPowerConsumption INTEGER } boxsPwrUsageHistoryUnitIndex OBJECT-TYPE SYNTAX INTEGER (1..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the unitIndex for the corresponding unit entry in the Power Usage History Table." ::= { boxsUnitPwrUsageHistoryEntry 1 } boxsPwrUsageHistoryUnitSampleIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the sampleIndex for the corresponding sample entry in the Power Usage History Table." ::= { boxsUnitPwrUsageHistoryEntry 2 } boxsPwrUsageHistoryUnitSampleTime OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-only STATUS current DESCRIPTION "Time at which the Sample was collected." ::= { boxsUnitPwrUsageHistoryEntry 3} boxsPwrUsageHistoryUnitPowerConsumption OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Power Consumption (mWatts) at the time of collecting the given sample." ::= { boxsUnitPwrUsageHistoryEntry 4 } boxsPwrUsageHistoryStackPowerConsumption OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Power Consumption (mWatts) per Stack at the time of collecting the given sample." ::= { boxsUnitPwrUsageHistoryEntry 5 } --************************************************************************************** -- boxServicesTempSensors boxServicesTempSensorsTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensor" ::= { boxServicesGroup 8 } boxServicesTempSensorsEntry OBJECT-TYPE SYNTAX BoxServicesTempSensorsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Sensor Entry" INDEX { boxServicesTempSensorIndex } ::= { boxServicesTempSensorsTable 1 } BoxServicesTempSensorsEntry ::= SEQUENCE { boxServicesTempSensorIndex Integer32, boxServicesTempSensorType INTEGER, boxServicesTempSensorState BoxsTemperatureStatus, boxServicesTempSensorTemperature Integer32 } boxServicesTempSensorIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique index of temperature sensor table entry" ::= { boxServicesTempSensorsEntry 1 } boxServicesTempSensorType OBJECT-TYPE SYNTAX INTEGER { fixed(1), removable(2), fixedAC(3), removableDC(4), fixedDC(5), removableAC(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of temperature sensor" ::= { boxServicesTempSensorsEntry 2 } boxServicesTempSensorState OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS read-only STATUS obsolete DESCRIPTION "The state of temperature sensor" ::= { boxServicesTempSensorsEntry 3 } boxServicesTempSensorTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature value reported by sensor" ::= { boxServicesTempSensorsEntry 4 } boxServicesTempUnitTable OBJECT-TYPE SYNTAX SEQUENCE OF BoxServicesTempUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature status table" ::= { boxServicesGroup 15 } boxServicesTempUnitEntry OBJECT-TYPE SYNTAX BoxServicesTempUnitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Box Services Temperature Unit Entry" INDEX { boxServicesTempUnitIndex } ::= { boxServicesTempUnitTable 1 } BoxServicesTempUnitEntry ::= SEQUENCE { boxServicesTempUnitIndex Unsigned32, boxServicesTempUnitState BoxsTemperatureStatus, boxServicesTempUnitTemperature Integer32 } boxServicesTempUnitIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unit index for an entry in the Box Services Temperature Unit Table" ::= { boxServicesTempUnitEntry 1 } boxServicesTempUnitState OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature state of the unit" ::= { boxServicesTempUnitEntry 2 } boxServicesTempUnitTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The highest temperature currently reported by any sensor on the unit" ::= { boxServicesTempUnitEntry 3 } --************************************************************************************** -- boxServicesNotificationsGroup -- -- This group provides notification definitions for the Box Services -- feature. -- --************************************************************************************** boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 } --************************************************************************************** -- boxServices notification definitions boxsItemStateChangeEvent OBJECT-TYPE SYNTAX INTEGER { insertion(1), removal(2), becomeoperational(3), failure(4), losepower(5) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions losepower - a power supply was operational, but the power to it has been disconnected or has failed" ::= { boxServicesNotificationsGroup 1 } boxsTemperatureChangeEvent OBJECT-TYPE SYNTAX INTEGER { abovethreshold(1), belowthreshold(2), withinnormalrange(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)" ::= { boxServicesNotificationsGroup 2 } boxsTemperatureStatusCurrentEvent OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes the current status of a switch." ::= { boxServicesNotificationsGroup 3 } boxsTemperatureStatusPreviousEvent OBJECT-TYPE SYNTAX BoxsTemperatureStatus MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "This event describes the previous status of a switch." ::= { boxServicesNotificationsGroup 4 } --************************************************************************************** -- Traps --************************************************************************************** fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 } boxsFanStateChange NOTIFICATION-TYPE OBJECTS { boxServicesFansIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when fan state change happens." ::= { fastPathBoxServicesTraps 1 } boxsPowSupplyStateChange NOTIFICATION-TYPE OBJECTS { boxServicesPowSupplyIndex, boxsItemStateChangeEvent } STATUS current DESCRIPTION "Trap is sent when power supply state change happens." ::= { fastPathBoxServicesTraps 2 } boxsTemperatureChange NOTIFICATION-TYPE OBJECTS { boxServicesTempSensorIndex, boxsTemperatureChangeEvent } STATUS obsolete DESCRIPTION "Trap is sent when temperature is changing and crossing any of the thresholds" ::= { fastPathBoxServicesTraps 3 } boxsThermalShutdown NOTIFICATION-TYPE OBJECTS { boxServicesThermalShutdownSensor, boxServicesThermalShutdownTemperature } STATUS current DESCRIPTION "Trap is sent when thermal shutdown is initiated." ::= { fastPathBoxServicesTraps 4 } boxsTemperatureStateChange NOTIFICATION-TYPE OBJECTS { boxServicesTempUnitIndex, boxsTemperatureStatusCurrentEvent, boxsTemperatureStatusPreviousEvent } STATUS current DESCRIPTION "Trap is sent when the system temperature crosses a threshold. To avoid rapid flapping between states, a hysteresis may be applied." ::= { fastPathBoxServicesTraps 5 } --************************************************************************************** -- Locator LED manage group -- -- This group provides manage definitions for the Locator LED feature. -- --************************************************************************************** boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 } boxsLocatorLedUnit OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Spesifies unit number where Locator LED should blink on. This is write-only value. It always returns '0' on request if the Locator Led feature is supported." ::= { boxsLocatorLedConfigGroup 1 } boxsLocatorLedTime OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates time period in seconds for Locator LED blinking. The range is from 20 to 3600 seconds. The dafault value is 20 seconds. This is write-only value. It always returns '0' on request if the Locator Led feature is supported." DEFVAL { 20 } ::= { boxsLocatorLedConfigGroup 2 } boxsLocatorLedEnable OBJECT-TYPE SYNTAX INTEGER { disable(0), enable(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Starts the Locator LED blinking. If boxsLocatorLedUnit has not been set current(manager) unit number will be used. If boxsLocatorLedTime has not been set default value(20 seconds) will be used. This is write-only value. It always returns '0' on request if the Locator Led feature is supported." ::= { boxsLocatorLedConfigGroup 3 } END