G6-PORT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, MacAddress FROM SNMPv2-TC g6 FROM MICROSENS-G6-MIB ; device MODULE-IDENTITY --Category LAST-UPDATED "201802121619Z" ORGANIZATION "MICROSENS GmbH & Co. KG" CONTACT-INFO "Kueferstrasse 16 D-59067 Hamm Germany support@microsens.de http://www.microsens.de" DESCRIPTION "Microsens private MIB for Generation 6 Ethernet Switches" REVISION "201802121619Z" DESCRIPTION "File creation" ::= { g6 1 } port OBJECT IDENTIFIER ::= { device 81 } -- *************************** CONFIGURATION SECTION ******************************** -- ******************* Begin of configTable ************************* configTable OBJECT-TYPE SYNTAX SEQUENCE OF ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This section defines the basic configuration parameter for each port." ::= { port 1 } configEntry OBJECT-TYPE SYNTAX ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { configPortIndex } ::= { configTable 1 } ConfigEntry ::= SEQUENCE { configPortIndex INTEGER, configAlias DisplayString, configPortOperation INTEGER , configRole INTEGER , configSpeed INTEGER , configMtu INTEGER , configLoopProtection INTEGER , configAutoNegotiation INTEGER , configFullDuplex INTEGER , configFlowcontrol INTEGER , configMdiMode INTEGER , configEnergyEfficiency INTEGER , configDualMediaMode INTEGER , configAllowedOutgoingPorts INTEGER } configPortIndex OBJECT-TYPE SYNTAX INTEGER (0..24) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { configEntry 1 } configAlias OBJECT-TYPE -- alias SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Alternative descriptive port name, user defineable." ::= { configEntry 2 } configPortOperation OBJECT-TYPE -- port_operation SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables the port for operation. When disabled, port is shut down." ::= { configEntry 3 } configRole OBJECT-TYPE -- role SYNTAX INTEGER { default (0), local (1), uplink (2), downlink (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines is a port is a regular local user port or a link to the network. This setting is references in various sanity checks throughout the system. When in doubt leave at default setting." ::= { configEntry 4 } configSpeed OBJECT-TYPE -- speed SYNTAX INTEGER { ms10Mbit (0), ms100Mbit (1), ms1000Mbit (2), sfpAuto (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When Auto-Negotiation is disabled sets the ports data rate to the selected speed. When Auto-Negotiation is enabled it determines the highest data rate advertised on port." ::= { configEntry 5 } configMtu OBJECT-TYPE -- mtu SYNTAX INTEGER { ms1522Byte (0), ms2048Byte (1), ms10240Byte (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "MTU used only to have a place holder for SNMP ifTable" ::= { configEntry 6 } configLoopProtection OBJECT-TYPE -- loop_protection SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Loop protection detects ethernet loops that can occur when cables are plugged in a way that the data send out of a port come back to the switch on another port. This will result in a data loop of endless packets. Such a loop condition seriously affects network performance and must be avoided." ::= { configEntry 7 } configAutoNegotiation OBJECT-TYPE -- auto_negotiation SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables Auto-Negotiation mode. When Auto-Negotiation mode is enabled, the parameters speed, full_duplex and flow_control determine the advertised port abilites. When Auto-Negotiation is disabled, the parameters speed, full_duplex and flow_control determine the fixed port configuration. Auto-Negotiation is not available for fiber ports in 100 Mbps mode and must be switched off." ::= { configEntry 8 } configFullDuplex OBJECT-TYPE -- full_duplex SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When Auto-Negotiation is disabled sets port to full duplex operation (when disabled, port is in half duplex mode). When Auto-Negotiation is enabled, it determines the advertisement of full duplex capability." ::= { configEntry 9 } configFlowcontrol OBJECT-TYPE -- flowcontrol SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When Auto-Negotiation is disabled sets port into flow control mode. When Auto-Negotiation is enabled, it determines the advertisement of flow control capability. Flow control is only supported when port is in full duplex mode." ::= { configEntry 10 } configMdiMode OBJECT-TYPE -- mdi_mode SYNTAX INTEGER { auto (0), forceMdiStd (1), forceMdix (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enables Auto MDI/MDI-X mode to automatically adapt port pinout to cable type used. When set to forced, port pinout is fixed." ::= { configEntry 11 } configEnergyEfficiency OBJECT-TYPE -- energy_efficiency SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable Energy Efficient Ethernet mode is only available for copper ports in 1000Base-T mode." ::= { configEntry 12 } configDualMediaMode OBJECT-TYPE -- dual_media_mode SYNTAX INTEGER { fiberPriority (0), copperPriority (1), forceFiber (2), forceCopper (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Define media selection for dual media ports. This function is only available on ports with dual media Phy." ::= { configEntry 13 } configAllowedOutgoingPorts OBJECT-TYPE -- allowed_outgoing_ports SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "This bitmask may be used to limit the outgoing traffic to certain ports. This feature is also known as port based vlan. Syntax: slot/port, slot/port or use hex value for quick setup = 0x3f (ports 1-6)" ::= { configEntry 14 } -- ********************* End of configTable *********************** -- ******************* Begin of monitorTable ************************* monitorTable OBJECT-TYPE SYNTAX SEQUENCE OF MonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port monitoring is a test tool which permits reading data from on port on another port for trouble shooting purposes." ::= { port 2 } monitorEntry OBJECT-TYPE SYNTAX MonitorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { monitorIndex } ::= { monitorTable 1 } MonitorEntry ::= SEQUENCE { monitorIndex INTEGER, monitorMode INTEGER , monitorSource INTEGER, monitorDestination Integer32 } monitorIndex OBJECT-TYPE SYNTAX INTEGER (0) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { monitorEntry 1 } monitorMode OBJECT-TYPE -- mode SYNTAX INTEGER { disabled (0), txOnly (1), rxOnly (2), rxAndTx (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines in which mode of port monitoring operation is used. Default is DISABLED for normal operation." ::= { monitorEntry 2 } monitorSource OBJECT-TYPE -- source SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Source port(2) of which the traffic is to be monitored. CLI Syntax: 1/1 for first port. 1/1,1/3 for first and third port" ::= { monitorEntry 3 } monitorDestination OBJECT-TYPE -- destination SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Port on which the traffic monitored on the source port shall be copied to. Normally a network sniffer is connected to this port. Please observe that possibly the VLAN setting of the destination port must match the that of the monitored ports. CLI Syntax: 1/1 for first port." ::= { monitorEntry 4 } -- ********************* End of monitorTable *********************** portRestartPort OBJECT-TYPE -- restart_port SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This function may be used to briefly disabled and enable the port. This may be used to restart port authentication for example. Please supply port number as parameter. The shorthand port format like 1 for 1/1 may be used. Syntax examples: restart_port = 1/2,1/5. " ::= { port 3 } -- ****************************** STATUS SECTION ******************************** portUplinkPorts OBJECT-TYPE -- uplink_ports SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which port(s) are connected to the network. The setting is derived from default setting and may be overridden by port.role setting." ::= { port 100 } portDownlinkPorts OBJECT-TYPE -- downlink_ports SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates to which port(s) a downstream switch is connected. The setting is derived from default setting and may be overridden by port.role setting." ::= { port 101 } -- ******************* Begin of statusTable ************************* statusTable OBJECT-TYPE SYNTAX SEQUENCE OF StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This status table indicates current port status and (negotiated) settings. It also displays if a port is logically blocked due to a certain protocol condition." ::= { port 102 } statusEntry OBJECT-TYPE SYNTAX StatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { statusPortIndex } ::= { statusTable 1 } StatusEntry ::= SEQUENCE { statusPortIndex INTEGER, statusLinkUp INTEGER , statusLastLinkChange DisplayString, statusLinkState INTEGER , statusRxActivity INTEGER , statusTxActivity INTEGER , statusMediaUsed INTEGER , statusSpeedUsed INTEGER , statusLoopedPort INTEGER, statusFullDuplexUsed INTEGER , statusFlowcontrolUsed INTEGER , statusMdiUsed INTEGER , statusEeeActive INTEGER , statusBlockingAlgorithm BITS , statusLearningAlgorithm BITS , statusForwardingAlgorithm BITS , statusUnauthorizedAlgorithm BITS } statusPortIndex OBJECT-TYPE SYNTAX INTEGER (0..31) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { statusEntry 1 } statusLinkUp OBJECT-TYPE -- link_up SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "False: Link is down, True: Link is up. For dual media ports this indicates the status of the active media." ::= { statusEntry 2 } statusLastLinkChange OBJECT-TYPE -- last_link_change SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Time when the link_up status changed the last time. Value may appear illogical if the system time is not properly set." ::= { statusEntry 3 } statusLinkState OBJECT-TYPE -- link_state SYNTAX INTEGER { linkDown (0), blocking (1), learning (2), forwarding (3), unauthVlan (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Logical port status." ::= { statusEntry 4 } statusRxActivity OBJECT-TYPE -- rx_activity SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates true when data activity on the receiver is detected." ::= { statusEntry 5 } statusTxActivity OBJECT-TYPE -- tx_activity SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates true when data activity on the transmitter is detected." ::= { statusEntry 6 } statusMediaUsed OBJECT-TYPE -- media_used SYNTAX INTEGER { none (0), copper (1), fiber (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "indicates which media is used for dual media ports" ::= { statusEntry 7 } statusSpeedUsed OBJECT-TYPE -- speed_used SYNTAX INTEGER { down (0), ms10Mbit (1), ms100Mbit (2), ms1000Mbit (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Actual (negotiated) port data rate." ::= { statusEntry 8 } statusLoopedPort OBJECT-TYPE -- looped_port SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Usually empty. When a port loop is detected through loop protection function then the looped port is indicated here." ::= { statusEntry 9 } statusFullDuplexUsed OBJECT-TYPE -- full_duplex_used SYNTAX INTEGER { none (0), full (1), half (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "False: Half duplex, True: Full duplex." ::= { statusEntry 10 } statusFlowcontrolUsed OBJECT-TYPE -- flowcontrol_used SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "False: No flow control, True: Use flow control." ::= { statusEntry 11 } statusMdiUsed OBJECT-TYPE -- mdi_used SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "False: MDI pinout, True: MDI-X pinout." ::= { statusEntry 12 } statusEeeActive OBJECT-TYPE -- eee_active SYNTAX INTEGER { false(0), true(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "When true Energy Efficent Ethernet is supported by both ends of the link and is active." ::= { statusEntry 13 } statusBlockingAlgorithm OBJECT-TYPE -- blocking_algorithm SYNTAX BITS { portIsEnabled (0), ms8021xApplies (1), rstpApplies (2), ringApplies (3), couplingApplies (4), loopPreventionApplies (5), macAuthApplies (6), bpduGuardApplies (7), dhcpFilterApplies (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flags indicate blocking request by which algorithm per port." ::= { statusEntry 14 } statusLearningAlgorithm OBJECT-TYPE -- learning_algorithm SYNTAX BITS { portIsEnabled (0), ms8021xApplies (1), rstpApplies (2), ringApplies (3), couplingApplies (4), loopPreventionApplies (5), macAuthApplies (6), bpduGuardApplies (7), dhcpFilterApplies (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flags indicate learning request by which algorithm per port." ::= { statusEntry 15 } statusForwardingAlgorithm OBJECT-TYPE -- forwarding_algorithm SYNTAX BITS { portIsEnabled (0), ms8021xApplies (1), rstpApplies (2), ringApplies (3), couplingApplies (4), loopPreventionApplies (5), macAuthApplies (6), bpduGuardApplies (7), dhcpFilterApplies (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flags indicate forwarding request by which algorithm per port." ::= { statusEntry 16 } statusUnauthorizedAlgorithm OBJECT-TYPE -- unauthorized_algorithm SYNTAX BITS { portIsEnabled (0), ms8021xApplies (1), rstpApplies (2), ringApplies (3), couplingApplies (4), loopPreventionApplies (5), macAuthApplies (6), bpduGuardApplies (7), dhcpFilterApplies (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Flags indicate use of unauthorized vlan request by which algorithm per port." ::= { statusEntry 17 } -- ********************* End of statusTable *********************** END