-- ============================================================================ -- Copyright (C) 2012 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: This MIB is used for defining Huawei's BTEST MIB objects, which -- is used for Broad test. -- Reference: -- Version: V3.14 -- ============================================================================ HUAWEI-BTEST-MIB DEFINITIONS ::= BEGIN IMPORTS huaweiUtility FROM HUAWEI-MIB HWPortType FROM HUAWEI-TC-MIB ifIndex FROM IF-MIB hwFrameIndex,hwSlotIndex FROM HUAWEI-DEVICE-MIB Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI TEXTUAL-CONVENTION, RowStatus FROM SNMPv2-TC hwTestGroupNo FROM HUAWEI-COMMTEST-MIB; hwBTest MODULE-IDENTITY LAST-UPDATED "201201090000Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "This MIB is used for defining Huawei's BTEST MIB objects,which is used for Broad test. " -- Revision history REVISION "201201090000Z" DESCRIPTION "V3.14, modify the description of the leaf hwBTSSAdslSeltTestParamUnCalibLineScale, hwBTSSAdslSeltTestParamUnCalibEchoRespReal, hwBTSSAdslSeltTestParamUnCalibEchoRespImg, hwBTSSAdslSeltTestParamCalibEchoRespReal, hwBTSSAdslSeltTestParamCalibEchoRespImg, hwBTSSAdslSeltTestParamVarUerC, hwBTSSAdslSeltTestParamQSPsdValue, hwBTSSAdslSeltTestParamUpShnCap, hwBTSSAdslSeltTestParamAttnAt180KHZ, hwBTSSAdslSeltTestParamAttnAt300KHZ, hwBTSSAdslSeltTestParamUerMmdC, hwBTSSAdslSeltTestParamQlnMmdC. " REVISION "201105040000Z" DESCRIPTION "V3.13, add leaf node hwBTSSAdslSeltTestParamCalcEnable of hwBTSSAdslSeltTestTable for setting selt test calculation switch. Add hwBTSSAdslSeltCalibrationTable for describing calibration data of selt test. " REVISION "201102220000Z" DESCRIPTION "V3.12, changes in this revision: modify the description of the leaf hwBTSSTestedPortOperMode,hwBTSSAdslSeltTestParamUmeC, hwBTSSAdslSeltTestParamCalibLineScale,hwBTSSAdslSeltTestParamQmeC, hwBTSSAdslSeltTestParamUnCalibLineScale,hwBTSSTestedPortOperMode. " REVISION "201102120000Z" DESCRIPTION "V3.11, changes in this revision: Add value resumeport(5) for hwBTSSTestedPortOperType. " REVISION "201010290000Z" DESCRIPTION "V3.10, changes in this revision: Add value -1(invalid) for hwBTSSAdslSeltLevel and modify the description. " REVISION "201009290000Z" DESCRIPTION "V3.09, changes in this revision: Add leaf node for new standard, include: hwBTSSAdslSeltTestParamVarUerC hwBTSSAdslSeltTestParamUerMmdC hwBTSSAdslSeltTestParamQlnMmdC hwBTSSAdslSeltTestParamUmeC hwBTSSAdslSeltTestParamQmeC hwBTSSAdslSeltTestParamUerStatus hwBTSSAdslSeltTestParamQlnStatus Modify the range of leaf node, include: hwBTSSAdslSeltTestParamUnCalibLineScale hwBTSSAdslSeltTestParamUnCalibEchoRespReal hwBTSSAdslSeltTestParamUnCalibEchoRespImg hwBTSSAdslSeltTestParamCalibLineScale hwBTSSAdslSeltTestParamCalibEchoRespReal hwBTSSAdslSeltTestParamCalibEchoRespImg hwBTSSAdslSeltTestParamQSPsdValue " REVISION "201009270900Z" DESCRIPTION "V3.08, changes in this revision: modify the description of the hwBTSSCaptureTrap. " REVISION "201007120900Z" DESCRIPTION "V3.07, changes in this revision: Add value -1(invalid) for hwBTSSTestedPortOperType and six enumerate values for hwBTSSTestedPortOperMode to support get operation. " REVISION "201006220900Z" DESCRIPTION "V3.06, changes in this revision: Modify chinese character. " REVISION "201003220000Z" DESCRIPTION "V3.05, changes in this revision: Add leaf node hwBTSSAdslSeltTestOperType of hwBTSSAdslSeltTestTable for setting or obtaining selt test operation type. Add leaf node hwBTSSAdslSeltTestParamLoopTermin of hwBTSSAdslSeltTestTable for obtaining selt test parameter Loop Termination. Add leaf node hwBTSSAdslSeltTestParamLoopGauge of hwBTSSAdslSeltTestTable for setting or obtaining selt test parameter Loop Gauge. Add leaf node hwBTSSAdslDeltTestOperType of hwBTSSAdslDeltTestTable for setting or obtaining delt test operation type. Modify MAX-ACCESS ,include: hwBTSSAdslSeltTestParamAttnAt180KHZ hwBTSSAdslSeltTestParamAttnAt300KHZ hwBTSSAdslSeltTestParamQSPsdValue " REVISION "201002080000Z" DESCRIPTION "V3.04, changes in this revision: Delete the definition of the trap node,include: hwBTSSCaptureTrap hwBTSSSeltStartReplyTrap hwBTSSSeltTestResultFirstFrameTrap hwBTSSSeltTestResultSecondFrameTrap hwBTSSSeltTestResultThirdFrameTrap hwBTSSSeltTestResultFourFrameTrap hwBTSSSeltTestResultFifthsFrameTrap hwBTSSSeltTestResultSixthFrameTrap hwBTSSSeltTestResultSeventhFrameTrap " REVISION "201001120000Z" DESCRIPTION "V3.03, changes in this revision: Add the definition of hwBTSSDeltResultDataTrap node. " REVISION "200906040900Z" DESCRIPTION "V3.02, changes in this revision: Add the definition of SYNTAX HWBTSSxDslLineOverLap, and change the SYNTAX from INTEGER to HWBTSSxDslLineOverLap for hwBTSSxDslLineOverlapType of table hwBTSSxDslLineCfgTable Add leaf hwBTSSCoTestBusyFlag into table hwBTSSCoTestTable OBJECT-TYPE Add hwBTSSAuxPortCfgTable for describing aux port used for BTSS. Add hwBTSSTestedPortOperTable for describing operation for tested port. Add hwBTSSCqtTransTestTable for describeing CQT test by transparent command. Add hwBTSSMultiFrameMiscOperTable for describing test relatived operation for multi-frame. Add hwBTSSAdslSeltTestTable for describing selt test for adsl2+. Add hwBTSSAdslDeltTestTable for describing Delt test for adsl2+. Add hwBTSSLoopLineToneOprTable for Loop Line Tone. Add leaf node hwBTSSTestedPortOperTrap for sending trap when tested port operation. Add leaf node hwBTSSCqtTransTestOperResultTrap for sending trap when starting or stoping Cqt transparent test. Add leaf node hwBTSSCqtTransTestResultTrap for sending trap when reporting the result after Cqt transparent test. Add leaf node hwBTSSLoopLineToneOperTrap for sending trap when reporting the test result of Loop Line Tone. Delete leafs hwBTSSxDslLineExtCrossMatrixRauModuleNo and wBTSSxDslLineExtCrossMatrixRauPortNo from table Delete tables, include: hwBTSSxDslLineCfgTable hwBTSSCqtTemplateTable hwBTSSCqtMaintainTable hwBTSSCqtFrTestTable hwBTSSCqtTdrTestTable hwBTSSCqtDmtTestTable hwBTSSCqtNseTestTable hwBTSSCqtLbTestTable hwBTSSCqtLcTestTable hwBTSSCqtFrTestResultTable hwBTSSCqtTdrTestResultTable hwBTSSCqtDmtTestResultTable hwBTSSCqtNseTestResultTable hwBTSSCqtLbTestResultTable hwBTSSCqtLcTestResultTable Delete traps, include: hwBTSSCqtFrTestTrap hwBTSSCqtTdrTestTrap hwBTSSCqtDmtTestTrap hwBTSSCqtNseTestTrap hwBTSSCqtLbTestTrap hwBTSSCqtLcTestTrap hwBTSSCqtStopFrTestTrap hwBTSSCqtStopTdrTestTrap hwBTSSCqtStopDmtTestTrap hwBTSSCqtStopNseTestTrap hwBTSSCqtStopLbTestTrap hwBTSSCqtStopLcTestTrap " REVISION "200308280900Z" DESCRIPTION "V3.00, change in this revision: Change the style of description. " REVISION "200306280900Z" DESCRIPTION "V2.00, change in this revision: Correct the SYNTAX. " REVISION "200304280900Z" DESCRIPTION "V1.00, initial version, by FixNet Mib Group." ::= { hwTest 3 } HWBTSSxDslLineOverLap ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Set overlap mode of xDSL with PSTN line. Options: 1. overLap(1) - xDSL overlap with POTS line 2. direct(2) - There is no pots line, no splitter, no phone 3. unknown(3) - The mode is unknown " SYNTAX INTEGER { overLap(1), direct(2), unknown(3) } CqtQualitativeResultString ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "This string to contain qualitative result." SYNTAX OCTET STRING (SIZE (0..255)) hwTest OBJECT IDENTIFIER ::= { huaweiUtility 21 } hwBTestMib OBJECT IDENTIFIER ::= { hwBTest 1 } hwBTestMIBObjects OBJECT IDENTIFIER ::= { hwBTestMib 1 } hwBTSSxDslLineCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSxDslLineCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The hwBTSSxDslLineCfgTable table describes xDSL line configuration. This table is used for bandwidth test. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 1 } hwBTSSxDslLineCfgEntry OBJECT-TYPE SYNTAX HwBTSSxDslLineCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The hwBTSSxDslLineCfgTable table describes xDSL line configuration. This table is used for bandwidth test. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSxDslLineCfgTable 1 } HwBTSSxDslLineCfgEntry ::= SEQUENCE { hwBTSSxDslLineOverlapType HWBTSSxDslLineOverLap } hwBTSSxDslLineOverlapType OBJECT-TYPE SYNTAX HWBTSSxDslLineOverLap MAX-ACCESS read-write STATUS current DESCRIPTION "Overlap mode of xDSL with PSTN line. Options: 1. overLap(1) - xDSL overlap with POTS line 2. direct(2) - There is no pots line, no splitter, no phone 3. unknown(3) - The mode is unknown Default: unknown(3) " DEFVAL { 3 } ::= { hwBTSSxDslLineCfgEntry 1 } hwBTSSCoTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSCoTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 2 } hwBTSSCoTestEntry OBJECT-TYPE SYNTAX HwBTSSCoTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "xDSL central office emulational measurement table.The table is used for xDSL central emulational measurement. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSCoTestTable 1 } HwBTSSCoTestEntry ::= SEQUENCE { hwBTSSCoOperType INTEGER, hwBTSSCoTestResult INTEGER, hwBTSSCoTestBusyFlag INTEGER } hwBTSSCoOperType OBJECT-TYPE SYNTAX INTEGER { stop(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CO emulational operation type. Options: 1. stop(1) - Stop CO emulational 2. start(2) - Start CO emulational " ::= { hwBTSSCoTestEntry 1 } hwBTSSCoTestResult OBJECT-TYPE SYNTAX INTEGER { normal(1), testfail(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "CO emulational test result. Options: 1. normal(1) - The test of CO emulational is successful 2. testfail(2) - Fail in test of CO emulational " ::= { hwBTSSCoTestEntry 2 } hwBTSSCoTestBusyFlag OBJECT-TYPE SYNTAX INTEGER { busyNoTest(1), busyTest(2), busystrenTest(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "CO force test flag Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy " ::= { hwBTSSCoTestEntry 3 } hwBTSSAuxPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSAuxPortCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration table of the broadband test auxiliary port This table is used to configure a certain type of emulation port required in the CO emulation test. The indexes of this table are hwTestGroupNo and hwBTSSAuxPortType. " ::= { hwBTestMIBObjects 17 } hwBTSSAuxPortCfgEntry OBJECT-TYPE SYNTAX HwBTSSAuxPortCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration table of the broadband test auxiliary port This table is used to configure a certain type of emulation port required in the CO emulation test. The indexes of this entry are hwTestGroupNo and hwBTSSAuxPortType. " INDEX { hwTestGroupNo, hwBTSSAuxPortType } ::= { hwBTSSAuxPortCfgTable 1 } HwBTSSAuxPortCfgEntry ::= SEQUENCE { hwBTSSAuxPortType INTEGER, hwBTSSAuxPortIfIndex Integer32, hwBTSSAuxPortRowStatus RowStatus } hwBTSSAuxPortType OBJECT-TYPE SYNTAX INTEGER { adsl(1), vdsl(2), gshdsl(3) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Assistance port type of BTSS. Options: 1. adsl(1) - Assistance port type of BTSS is adsl 2. vdsl(2) - Assistance port type of BTSS is vdsl 3. gshdsl(3) - Assistance port type of BTSS is gshdsl " ::= { hwBTSSAuxPortCfgEntry 1 } hwBTSSAuxPortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Assistance port ifIndex of BTSS." ::= { hwBTSSAuxPortCfgEntry 2 } hwBTSSAuxPortRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status(add(4),delete(6))." ::= { hwBTSSAuxPortCfgEntry 3 } hwBTSSTestedPortOperTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSTestedPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes operation for tested port. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 18 } hwBTSSTestedPortOperEntry OBJECT-TYPE SYNTAX HwBTSSTestedPortOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes operation for tested port. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSTestedPortOperTable 1 } HwBTSSTestedPortOperEntry ::= SEQUENCE { hwBTSSTestedPortOperType INTEGER, hwBTSSTestedPortOperMode INTEGER, hwBTSSTestedPortOperResult INTEGER, hwBTSSTestedPortTestBusyFlag INTEGER, hwBTSSTestedPortTestPOTSFlag INTEGER } hwBTSSTestedPortOperType OBJECT-TYPE SYNTAX INTEGER { capture(1), release(2), startmonitor(3), stopmonitor(4), resumeport(5), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operation type of BTSS tested port. Options: 1. capture(1) - Capture 2. release(2) - Release 3. startmonitor(3) - Start monitor 4. stopmonitor(4) - Stop monitor 5. resumeport(5) - Resume port 6. invalid(-1) - Invalid value " ::= { hwBTSSTestedPortOperEntry 1 } hwBTSSTestedPortOperMode OBJECT-TYPE SYNTAX INTEGER { inline(1), outline(2), monitor(3), both(4), meltNoCutxDSL(5), meltForceCutxDSL(6), testLineLoopback(7), internalResistorLoopback(8), passthroughmode(9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operation mode of BTSS tested port. Options: 1. inline(1) - BTSS tested port in test 2. outline(2) - BTSS tested port out test 3. monitor(3) - Monitoring BTSS tested port 4. both(4) - Capture for circuit and loop-line test 5. meltNoCutxDSL(5) - Capture for melt chip test with co and cpe connecting 6. meltForceCutxDSL(6) - Capture for melt chip test with co and cpe disconnecting 7. testLineLoopback(7) - Capture for test line loopback 8. internalResistorLoopback(8) - Capture for internal resistor loopback 9. passthroughmode(9) - No capture Default: passthroughmode(9) " ::= { hwBTSSTestedPortOperEntry 2 } hwBTSSTestedPortOperResult OBJECT-TYPE SYNTAX INTEGER { normal(1), fail(2), timeout(4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Test result of BTSS tested port. Options: 1. normal(1) - The test of BTSS tested port is successful 2. fail(2) - Fail in test of BTSS tested port 3. timeout(4) - The test of BTSS tested port is timeout " ::= { hwBTSSTestedPortOperEntry 3 } hwBTSSTestedPortTestBusyFlag OBJECT-TYPE SYNTAX INTEGER { busyNoTest(1), busyTest(2), busystrenTest(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tested port force test. Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy " ::= { hwBTSSTestedPortOperEntry 4 } hwBTSSTestedPortTestPOTSFlag OBJECT-TYPE SYNTAX INTEGER { noCutPOTS(1), busyNoTest(2), busyTest(3), busystrenTest(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tested port POTS service flag Options: 1. noCutPOTS(1) - No cut off POTS 2. busyNoTest(2) - No test on POTS busy (Cut off POTS) 3. busyTest(3) - Test on POTS busy (Cut off POTS) 4. busystrenTest(4) - Forced test on POTS busy (Cut off POTS) " ::= { hwBTSSTestedPortOperEntry 5 } hwBTSSCqtTransTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSCqtTransTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes CQT test by transparent command. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 19 } hwBTSSCqtTransTestEntry OBJECT-TYPE SYNTAX HwBTSSCqtTransTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes CQT test by transparent command. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSCqtTransTestTable 1 } HwBTSSCqtTransTestEntry ::= SEQUENCE { hwBTSSCqtTransTestOperType INTEGER, hwBTSSCqtTransTestCRCMode INTEGER, hwBTSSCqtTransTestOperResult INTEGER, hwBTSSCqtTransTestTxCmd OCTET STRING, hwBTSSCqtTransTestResultNo Integer32, hwBTSSCqtTransTestResultLastFlag INTEGER, hwBTSSCqtTransTestResult OCTET STRING } hwBTSSCqtTransTestOperType OBJECT-TYPE SYNTAX INTEGER { stop(1), start(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CQT transparent Operation type Options: 1. stop(1) - Stop CQT transparent test 2. start(2) - Start CQT transparent test " ::= { hwBTSSCqtTransTestEntry 1 } hwBTSSCqtTransTestCRCMode OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "CRC Operation type of CQT transparent. Options: 1. disable(1) - Disable CQT transparent 2. enable(2) - Enable CQT transparent Default: disable(1) " DEFVAL { 1 } ::= { hwBTSSCqtTransTestEntry 2 } hwBTSSCqtTransTestOperResult OBJECT-TYPE SYNTAX INTEGER { normal(1), fail(2), abort(3), powerfeed(4) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "CQT transparent Operation result. Options: 1. normal(1) - The CQT transparent test is successful 2. fail(2) - The CQT transparent test fails 3. abort(3) - The CQT transparent test aborts 4. powerfeed(4) - The CQT transparent test power feeds " ::= { hwBTSSCqtTransTestEntry 3 } hwBTSSCqtTransTestTxCmd OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..251)) MAX-ACCESS read-write STATUS current DESCRIPTION "Sending command string in TL1 format." ::= { hwBTSSCqtTransTestEntry 4 } hwBTSSCqtTransTestResultNo OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Test result No. Range: 1-255 " ::= { hwBTSSCqtTransTestEntry 5 } hwBTSSCqtTransTestResultLastFlag OBJECT-TYPE SYNTAX INTEGER{false(0), true(1)} MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Last package flag for test result. Options: 1. false(0) - This is not the last package 2. true(1) - The last package " ::= { hwBTSSCqtTransTestEntry 6 } hwBTSSCqtTransTestResult OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..231)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "CQT transparent Test result." ::= { hwBTSSCqtTransTestEntry 7 } hwBTSSMultiFrameMiscOperTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSMultiFrameMiscOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes test relatived operation for multi-frame. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 20 } hwBTSSMultiFrameMiscOperEntry OBJECT-TYPE SYNTAX HwBTSSMultiFrameMiscOperEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes test relatived operation for multi-frame. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSMultiFrameMiscOperTable 1 } HwBTSSMultiFrameMiscOperEntry ::= SEQUENCE { hwBTSSMultiFrameMiscCleanTest INTEGER, hwBTSSMultiFrameMiscTestedFrame Integer32, hwBTSSMultiFrameMiscTestedPortType HWPortType, hwBTSSMultiFrameMiscTestedLineType HWBTSSxDslLineOverLap } hwBTSSMultiFrameMiscCleanTest OBJECT-TYPE SYNTAX INTEGER{start(1)} MAX-ACCESS read-write STATUS current DESCRIPTION "Clean current test on specified frame. Options: 1. start(1) - Start clean current test " ::= { hwBTSSMultiFrameMiscOperEntry 1 } hwBTSSMultiFrameMiscTestedFrame OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Tested frame of BTSS multi-frame. Default: 0 " DEFVAL { 0 } ::= { hwBTSSMultiFrameMiscOperEntry 2 } hwBTSSMultiFrameMiscTestedPortType OBJECT-TYPE SYNTAX HWPortType MAX-ACCESS read-write STATUS current DESCRIPTION "Tested port type of BTSS multi-frame." ::= { hwBTSSMultiFrameMiscOperEntry 3 } hwBTSSMultiFrameMiscTestedLineType OBJECT-TYPE SYNTAX HWBTSSxDslLineOverLap MAX-ACCESS read-write STATUS current DESCRIPTION "Tested line type of BTSS multi-frame." ::= { hwBTSSMultiFrameMiscOperEntry 4 } hwBTSSAdslSeltTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HWBTSSAdslSeltTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes selt test for adsl2+. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 21 } hwBTSSAdslSeltTestEntry OBJECT-TYPE SYNTAX HWBTSSAdslSeltTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes selt test for adsl2+. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSAdslSeltTestTable 1 } HWBTSSAdslSeltTestEntry ::= SEQUENCE { hwBTSSAdslSeltTestOperType INTEGER , hwBTSSAdslSeltTestOperResult INTEGER , hwBTSSAdslSeltTestResultNo Integer32 , hwBTSSAdslSeltTestResultLastFlag INTEGER , hwBTSSAdslSeltTestResult OCTET STRING , hwBTSSAdslSeltTestParamLoopLength Integer32 , hwBTSSAdslSeltTestParamLoopTermin INTEGER , hwBTSSAdslSeltTestParamLoopGauge INTEGER , hwBTSSAdslSeltTestParamUpShnCap Integer32 , hwBTSSAdslSeltTestParamDwnShnCap Integer32 , hwBTSSAdslSeltTestParamInbandNoise OCTET STRING , hwBTSSAdslSeltTestParamTerminResp OCTET STRING , hwBTSSAdslSeltTestParamUpMgnAtRate OCTET STRING , hwBTSSAdslSeltTestParamDwnMgnAtRate OCTET STRING , hwBTSSAdslSeltTestParamUpRateAtMgn OCTET STRING , hwBTSSAdslSeltTestParamDwnRateAtMgn OCTET STRING , hwBTSSAdslSeltTestParamLoopAttenAtFreq OCTET STRING, hwBTSSAdslSeltTestParamUnCalibLineScale Unsigned32, hwBTSSAdslSeltTestParamUnCalibEchoRespReal OCTET STRING, hwBTSSAdslSeltTestParamUnCalibEchoRespImg OCTET STRING, hwBTSSAdslSeltTestParamCalibLineScale Unsigned32, hwBTSSAdslSeltTestParamCalibEchoRespReal OCTET STRING, hwBTSSAdslSeltTestParamCalibEchoRespImg OCTET STRING, hwBTSSAdslSeltTestParamVarUerC OCTET STRING, hwBTSSAdslSeltTestParamUerMmdC Unsigned32, hwBTSSAdslSeltTestParamQlnMmdC Unsigned32, hwBTSSAdslSeltTestParamUmeC INTEGER, hwBTSSAdslSeltTestParamQmeC INTEGER, hwBTSSAdslSeltTestParamUerStatus INTEGER, hwBTSSAdslSeltTestParamQlnStatus INTEGER, hwBTSSAdslSeltTestParamCalcEnable INTEGER, hwBTSSAdslSeltTestParamAttnAt180KHZ Integer32, hwBTSSAdslSeltTestParamAttnAt300KHZ Integer32, hwBTSSAdslSeltTestParamQSPsdValue OCTET STRING } hwBTSSAdslSeltTestOperType OBJECT-TYPE SYNTAX INTEGER { stop(1), start(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selt test operation type. Options: 1. stop(1) - Stop selt test of BTSS 2. start(2) - Start selt test of BTSS 3. invalid(-1) - No operation " ::= { hwBTSSAdslSeltTestEntry 1 } hwBTSSAdslSeltTestOperResult OBJECT-TYPE SYNTAX INTEGER { normal(1), fail(2), abort(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Selt test operation result. Options: 1. normal(1) - Selt test of BTSS is successful 2. fail(2) - Fail in selt test of BTSS 3. abort(3) - Selt test of BTSS aborts " ::= { hwBTSSAdslSeltTestEntry 2 } hwBTSSAdslSeltTestResultNo OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Selt test result serial number. Range: 1-255 " ::= { hwBTSSAdslSeltTestEntry 3 } hwBTSSAdslSeltTestResultLastFlag OBJECT-TYPE SYNTAX INTEGER{false(0), true(1)} MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Last package flag of test. Options: 1. false(0) - This is not the last package 2. true(1) - The last package " ::= { hwBTSSAdslSeltTestEntry 4 } hwBTSSAdslSeltTestResult OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Selt test result data." ::= { hwBTSSAdslSeltTestEntry 5 } hwBTSSAdslSeltTestParamLoopLength OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Loop Length. The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned." ::= { hwBTSSAdslSeltTestEntry 6 } hwBTSSAdslSeltTestParamLoopTermin OBJECT-TYPE SYNTAX INTEGER { open(0), short(1), unknow(2), terminated(3), invalid(-1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Loop Termination state. Options: 1. open(0) - Indicates that the line terminal is started 2. short(1) - Indicates that the line terminal is short-circuited 3. unknow(2) - Indicates the unknown state 4. terminated(3) - Indicates that the line terminal is stopped 5. invalid(-1) - Indicates the invalid state " ::= { hwBTSSAdslSeltTestEntry 7 } hwBTSSAdslSeltTestParamLoopGauge OBJECT-TYPE SYNTAX INTEGER { greater26awg(1), equal26awg(2), equal24awg(3), less24awg(4), unknowawg(5), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Selt test parameter Loop Gauge. Options: 1. greater26awg(1) - Indicates that the line gauge is greater than 26 2. equal26awg(2) - Indicates that the line gauge is 26 3. equal24awg(3) - Indicates that the line gauge is 24 4. less24awg(4) - Indicates that the line gauge is smaller than 24 5. unknowawg(5) - Indicates an unknown line gauge. 6. invalid(-1) - Indicates an invalid value. " ::= { hwBTSSAdslSeltTestEntry 8 } hwBTSSAdslSeltTestParamUpShnCap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Upstream Shannon Capacity. The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned." ::= { hwBTSSAdslSeltTestEntry 9 } hwBTSSAdslSeltTestParamDwnShnCap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Downstream Shannon Capacity." ::= { hwBTSSAdslSeltTestEntry 10 } hwBTSSAdslSeltTestParamInbandNoise OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Inband Noise 512 values that indicate inband noise in dBm/Hz, covering ADSL, ADSL2, and ADSL2+ bands, from 0 to 2.2 MHz. " ::= { hwBTSSAdslSeltTestEntry 11 } hwBTSSAdslSeltTestParamTerminResp OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Termination Response 180 values that indicate termination response magnitude from 0 to 18 kft. " ::= { hwBTSSAdslSeltTestEntry 12 } hwBTSSAdslSeltTestParamUpMgnAtRate OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Upstream Ratevs. Margin. This value is a measure of the quality of your upstream data signal relative to the noise on the line. Hundreds of values that indicate SNR margin in DB/Hz at a particular bit rate are provided, at a certain increments, up to 30 Mbps. This information may be plotted with the bit rate on the X-axis and the SNR margin on the Y-axis. " ::= { hwBTSSAdslSeltTestEntry 13 } hwBTSSAdslSeltTestParamDwnMgnAtRate OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Downstream Rate vs. Margin. This value is a measure of the quality of your downstream data signal relative to the noise on the line. Hundreds of values that indicate SNR margin in DB/Hz at a particular bit rate are provided, at a certain increments, up to 30 Mbps. This information may be plotted with the bit rate on the X-axis and the SNR margin on the Y-axis. " ::= { hwBTSSAdslSeltTestEntry 14 } hwBTSSAdslSeltTestParamUpRateAtMgn OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Upstream Margin vs. Rate." ::= { hwBTSSAdslSeltTestEntry 15 } hwBTSSAdslSeltTestParamDwnRateAtMgn OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter Downstream Margin vs. Rate." ::= { hwBTSSAdslSeltTestEntry 16 } hwBTSSAdslSeltTestParamLoopAttenAtFreq OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter loop attenuation versus frequency. Every four bytes constitute the result of a tone. This information may be plotted with the bit frequency on the X-axis and the loop attenuation on the Y-axis. " ::= { hwBTSSAdslSeltTestEntry 17 } hwBTSSAdslSeltTestParamUnCalibLineScale OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented. " ::= { hwBTSSAdslSeltTestEntry 18 } hwBTSSAdslSeltTestParamUnCalibEchoRespReal OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented. " ::= { hwBTSSAdslSeltTestEntry 19 } hwBTSSAdslSeltTestParamUnCalibEchoRespImg OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index i ranging from 0 to NSC-1, the subcarrier spacing, Df = 4.3125 kHz, and (NSC-1) * UER_G * Df is the highest frequency supported by the SELT-PMD functionality. The UER granularity parameter, UER_G, has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the uncalibrated echo response is being reported over a frequency range of 17.664 MHz or lower, UER_G shall be set to 1. If the uncalibrated echo response is being reported over a frequency range that is greater than 17.664 MHz, UER_G shall be set to 2. The scale factor shall be coded as a 32-bit unsigned integer. Both a(i) and b(i) shall be coded as 32-bit 2's complement signed integers. The value of UER(i* UER_G*Df) shall be defined as: UER(i* UER_G*Df) = (scale/2^31)*(a(i)+j*b(i))/2^31. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 2^31-1. NOTE - This data format supports an UER(f) granularity of 2^-31 and an UER(f) dynamic range of approximately +6 dB to -186 dB, however it does not imply any future accuracy requirements. An UER(i*UER_G* Df) value indicated as a(i) = b(i) = -2^31 is a special value. It indicates that no measurement could be done for this subcarrier either because it is not supported by the SELT-PMD function, or that the value is out of range to be represented. " ::= { hwBTSSAdslSeltTestEntry 20 } hwBTSSAdslSeltTestParamCalibLineScale OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The scale factor of calibrated echo response shall be coded as a 16 bit unsigned integer. " ::= { hwBTSSAdslSeltTestEntry 21 } hwBTSSAdslSeltTestParamCalibEchoRespReal OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "The calibrated echo response UER(i* f), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality. The scale factor shall be coded as a 16 bit unsigned integer. Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer. The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15 and an UER(f) dynamic range of approximately +6 dB to -90 dB. An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value. It indicates that no measurement could be done for this subcarrier because it is out of the PSD mask passband or that the value is out of range to be represented. " ::= { hwBTSSAdslSeltTestEntry 22 } hwBTSSAdslSeltTestParamCalibEchoRespImg OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "The calibrated echo response UER(i* f), shall be represented in linear format by a scale factor and a normalized complex number a(i)+j*b(i), where i is the subcarrier index i ranging from 0 to NSC-1 and Df = 4.3125kHz and (NSC-1) * Df is the highest frequency supported by the SELT-PMD functionality. The scale factor shall be coded as a 16 bit unsigned integer. Both a(i) and b(i) shall be coded as a 16 bit 2's complement signed integer. The value of UER(i* f) shall be defined as UER(i* f) = (scale/215)*(a(i)+j*b(i))/215. In order to maximize precision, the scale factor shall be chosen such that max(|a(i)|, |b(i)|) over all i is equal to 215-1. This data format supports an UER(f) granularity of 2-15 and an UER(f) dynamic range of approximately +6 dB to -90 dB. An UER(i*Df) value indicated as a(i) = b(i) = -215 is a special value. It indicates that no measurement could be done for this subcarrier because it is out of the PSD mask passband or that the value is out of range to be represented. " ::= { hwBTSSAdslSeltTestEntry 23 } hwBTSSAdslSeltTestParamVarUerC OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..2048)) MAX-ACCESS read-only STATUS current DESCRIPTION "The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to NSC-1. The value of REL_VAR_UER(i* UER_G *Df) shall be defined as REL_VAR_UER(i* UER_G *Df) = 3 - v(i)/2 dB. The number v(i) is an 8-bit unsigned integer in the range 0 to 254. This data format supports a REL_VAR_UER(i) over a range from -124 dB to +3 dB for each carrier with a granularity from 0.5 dB. Out of range values shall be clamped to the closest range bound. The special value v(i) = 255 indicates that no measurement is available for that carrier. Unit: 0.5dB " ::= { hwBTSSAdslSeltTestEntry 24 } hwBTSSAdslSeltTestParamUerMmdC OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is the maximum allowed time for SELT uncalibrated echo response measurement, between the time of the start command written by the SELT-PMD-ME, and the time the result is available for read operation by SELT-PMD-ME. It is configurable between 5 seconds and 240 seconds, in steps of 1 second. The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned. Unit: 1 second " ::= { hwBTSSAdslSeltTestEntry 25 } hwBTSSAdslSeltTestParamQlnMmdC OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is the maximum allowed time for SELT quiet line noise measurement, between the time of the start command written by the SELT-PMD-ME, and the time the result is available for read operation by SELT-PMD-ME. It is configurable between 1 second and 240 seconds, in steps of 1 second. The invalid value is 255. If data on the port cannot be queried, the invalid value will be returned. Unit: 1 second " ::= { hwBTSSAdslSeltTestEntry 26 } hwBTSSAdslSeltTestParamUmeC OBJECT-TYPE SYNTAX INTEGER{enable(1),disable(2),invalid(-1)} MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is a binary variable. Options: 1.enable(1) - Enable UER capture switch 2.disable(2) - Disable UER capture switch 3.invalid(-1) - Invalid value " ::= { hwBTSSAdslSeltTestEntry 27 } hwBTSSAdslSeltTestParamQmeC OBJECT-TYPE SYNTAX INTEGER{enable(1),disable(2),invalid(-1)} MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is a binary variable. Options: 1.enable(1) - Enable QLN capture switch 2.disable(2) - Disable QLN capture switch 3.invalid(-1) - Invalid value " ::= { hwBTSSAdslSeltTestEntry 28 } hwBTSSAdslSeltTestParamUerStatus OBJECT-TYPE SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "UerStatus. Options: 1.off(1) - The status is off. 2.running(2) - The status is running. 3.completed(3) - The status is completed. 4.failed(4) - The status is failed. " ::= { hwBTSSAdslSeltTestEntry 29 } hwBTSSAdslSeltTestParamQlnStatus OBJECT-TYPE SYNTAX INTEGER{off(1), running(2),completed(3),failed(4)} MAX-ACCESS read-only STATUS current DESCRIPTION "QlnStatus. Options: 1.off(1) - The status is off. 2.running(2) - The status is running. 3.completed(3) - The status is completed. 4.failed(4) - The status is failed. " ::= { hwBTSSAdslSeltTestEntry 30 } hwBTSSAdslSeltTestParamCalcEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "The status of calculation switch. Options: 1. enable(1) - Enable calculation switch 2. disable(2) - Disable calculation switch 3. invalid(-1) - Invalid value Default: enable(1) " DEFVAL { enable } ::= { hwBTSSAdslSeltTestEntry 31 } hwBTSSAdslSeltTestParamAttnAt180KHZ OBJECT-TYPE SYNTAX Integer32 UNITS "0.1dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter attenuation at 180KHZ. It ranges from -1100 to 0 units of 0.1dB(physical values are -110 to 0 dB). The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned. Unit: 0.1dB " ::= { hwBTSSAdslSeltTestEntry 65535 } hwBTSSAdslSeltTestParamAttnAt300KHZ OBJECT-TYPE SYNTAX Integer32 UNITS "0.1dB" MAX-ACCESS read-only STATUS current DESCRIPTION "Selt test parameter attenuation at 300KHZ. It ranges from -1100 to 0 units of 0.1dB(physical values are -110 to 0 dB). The invalid value is -1. If no SELT is performed, no SELT data is generated because the SELT is incomplete, or no SELT data can be obtained from the port because the SELT data is aged and cleared, the invalid value will be returned. Unit: 0.1dB " ::= { hwBTSSAdslSeltTestEntry 65536 } hwBTSSAdslSeltTestParamQSPsdValue OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1024)) UNITS "0.5dBm/Hz" MAX-ACCESS read-only STATUS current DESCRIPTION "The SELT quiet line noise provides the quiet line noise PSD as measured by the SELT-PMD function (see clause A.1.1.2) for each sub-carrier frequency i * SELTQLN_G * Df where i ranges from 0 to NSC-1, Df = 4.3125 kHz, and (NSC-1) * SELTQLN_G * Df is the highest frequency supported by the SELT-PMD functionality. SELTQLN_G has two valid values: 1 and 2, indicating whether the measurements were performed using a tone spacing of 4.3125 kHz or of 8.625 kHz. If the SELT quiet line noise is being reported over a frequency range of 17.664 MHz or lower, SELTQLN_G shall be set to 1. If the SELT quiet line noise is being reported over a frequency range that is greater than 17.664 MHz, SELTQLN_G shall be set to 2. SELT quiet line noise SELTQLN(i * SELTQLN_G * Df) shall be represented as an 8-bit unsigned integer n(i), where i is the subcarrier index i = 0 to NSC-1. The value of SELTQLN(i * SELTQLN_G * Df) shall be defined as SELTQLN(i * SELTQLN_G * Df ) = -23 - (n(i)/2) dBm/Hz. This data format supports a SELTQLN(f) granularity of 0.5 dB and an SELTQLN(f) dynamic range of -150 to -23 dBm/Hz. Unit: 0.5dBm/Hz " ::= { hwBTSSAdslSeltTestEntry 65537 } hwBTSSAdslDeltTestTable OBJECT-TYPE SYNTAX SEQUENCE OF HWBTSSAdslDeltTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes Delt test for adsl2+. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 22 } hwBTSSAdslDeltTestEntry OBJECT-TYPE SYNTAX HWBTSSAdslDeltTestEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes Delt test for adsl2+. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSAdslDeltTestTable 1 } HWBTSSAdslDeltTestEntry ::= SEQUENCE { hwBTSSAdslDeltTestOperType INTEGER , hwBTSSAdslDeltTestOperResult INTEGER , hwBTSSAdslDeltTestResultNo Integer32 , hwBTSSAdslDeltTestResultLastFlag INTEGER , hwBTSSAdslDeltTestResult OCTET STRING } hwBTSSAdslDeltTestOperType OBJECT-TYPE SYNTAX INTEGER { stop(1), start(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Delt test operation type. Options: 1. stop(1) - Delt test stop 2. start(2) - Start delt test 3. invalid(-1) - No operation " ::= { hwBTSSAdslDeltTestEntry 1 } hwBTSSAdslDeltTestOperResult OBJECT-TYPE SYNTAX INTEGER { normal(1), fail(2), abort(3) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Delt test operation result. Options: 1. normal(1) - Delt test is normal 2. fail(2) - Fail in delt test 3. abort(3) - Delt test aborts " ::= { hwBTSSAdslDeltTestEntry 2 } hwBTSSAdslDeltTestResultNo OBJECT-TYPE SYNTAX Integer32(1..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Delt test result serial number. Range: 1-255 " ::= { hwBTSSAdslDeltTestEntry 3 } hwBTSSAdslDeltTestResultLastFlag OBJECT-TYPE SYNTAX INTEGER{false(0), true(1)} MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Last package flag for test result. Options: 1. false(0) - This is not the last package 2. true(1) - The last package " ::= { hwBTSSAdslDeltTestEntry 4 } hwBTSSAdslDeltTestResult OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..1500)) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Delt test result data." ::= { hwBTSSAdslDeltTestEntry 5 } -- Loop line tone Begin hwBTSSLoopLineToneOprTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSLoopLineToneOprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 23 } hwBTSSLoopLineToneOprEntry OBJECT-TYPE SYNTAX HwBTSSLoopLineToneOprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table hwBTSSLoopLineToneOprTable is used to Loop Line Tone. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSLoopLineToneOprTable 1 } HwBTSSLoopLineToneOprEntry ::= SEQUENCE { hwBTSSLoopLineToneOprType INTEGER, hwBTSSLoopLineToneIntensity INTEGER, hwBTSSLoopLineToneBusyFlag INTEGER, hwBTSSLoopLineToneResult INTEGER } hwBTSSLoopLineToneOprType OBJECT-TYPE SYNTAX INTEGER { check(1), send(2), stopsend(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Operation type of BTSS loop line tone Options: 1. check(1) - Indicates that checking the signal tone is started 2. send(2) - Indicates that sending the signal tone is started 3. stopsend(3) - Indicates that stopping sending the signal tone is started " ::= { hwBTSSLoopLineToneOprEntry 1 } hwBTSSLoopLineToneIntensity OBJECT-TYPE SYNTAX INTEGER { fivedB(1), tendB(2), fifteendB(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tone intensity of BTSS loop line tone. Options: 1. fivedB(1) - Tone intensity of BTSS is five dB 2. tendB(2) - Tone intensity of BTSS is ten dB 3. fifteendB(3) - Tone intensity of BTSS is fifteen dB " ::= { hwBTSSLoopLineToneOprEntry 2 } hwBTSSLoopLineToneBusyFlag OBJECT-TYPE SYNTAX INTEGER { busyNoTest(1), busyTest(2), busystrenTest(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tested port force test of BTSS loop line tone. Options: 1. busyNoTest(1) - No test on busy 2. busyTest(2) - Test on busy 3. busystrenTest(3) - Forced test on busy " ::= { hwBTSSLoopLineToneOprEntry 3 } hwBTSSLoopLineToneResult OBJECT-TYPE SYNTAX INTEGER { succeed(1), failed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Operate result of BTSS loop line tone. Options: 1. succeed(1) - The test of BTSS loop line tone is successful 2. failed(2) - Failed in BTSS loop line tone test " ::= { hwBTSSLoopLineToneOprEntry 4 } --loop line tone End hwBTSSSeltAuxPortCfgTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSSeltAuxPortCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table sets assistance port for SELT. The index of this table is hwBTSSSeltAuxedPortIfIndex. " ::= { hwBTestMIBObjects 24 } hwBTSSSeltAuxPortCfgEntry OBJECT-TYPE SYNTAX HwBTSSSeltAuxPortCfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table sets assistance port for SELT. The index of this entry is hwBTSSSeltAuxedPortIfIndex. " INDEX { hwBTSSSeltAuxedPortIfIndex } ::= { hwBTSSSeltAuxPortCfgTable 1 } HwBTSSSeltAuxPortCfgEntry ::= SEQUENCE { hwBTSSSeltAuxedPortIfIndex Integer32, hwBTSSSeltAuxPortIfIndex Integer32, hwBTSSSeltAuxPortRowStatus RowStatus } hwBTSSSeltAuxedPortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifindex of the Auxed port. If there is only one global Auxed port, the value is 65535. " ::= { hwBTSSSeltAuxPortCfgEntry 1 } hwBTSSSeltAuxPortIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Assistance port ifIndex" ::= { hwBTSSSeltAuxPortCfgEntry 2 } hwBTSSSeltAuxPortRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Row status(add(4), delete(6)) of the Aux port." ::= { hwBTSSSeltAuxPortCfgEntry 3 } -- 1.3.6.1.4.1.2011.6.21.3.1.1.25 hwBTSSAdslSeltLevelTable OBJECT-TYPE SYNTAX SEQUENCE OF HwBTSSAdslSeltLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table supports the configuration of adsl selt level. The indexes of this table are hwFrameIndex and hwSlotIndex. " ::= { hwBTestMIBObjects 25 } -- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1 hwBTSSAdslSeltLevelEntry OBJECT-TYPE SYNTAX HwBTSSAdslSeltLevelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table supports the configuration of adsl selt level. The indexes of this entry are hwFrameIndex and hwSlotIndex. " INDEX { hwFrameIndex, hwSlotIndex } ::= { hwBTSSAdslSeltLevelTable 1 } HwBTSSAdslSeltLevelEntry ::= SEQUENCE { hwBTSSAdslSeltLevel Integer32 } -- 1.3.6.1.4.1.2011.6.21.3.1.1.25.1.1 hwBTSSAdslSeltLevel OBJECT-TYPE SYNTAX Integer32 (-1 | 1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "The level of adsl SELT: 1 Level0; 2 Level1; 3 Level2; 4 Level3. A special value of -1 indicates the level of adsl SELT is invalid. " ::= { hwBTSSAdslSeltLevelEntry 1 } -- 1.3.6.1.4.1.2011.6.21.3.1.1.26 hwBTSSAdslSeltCalibrationTable OBJECT-TYPE SYNTAX SEQUENCE OF HWBTSSAdslSeltCalibrationtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes calibration data of selt test. The index of this table is ifIndex. " ::= { hwBTestMIBObjects 26 } hwBTSSAdslSeltCalibrationEntry OBJECT-TYPE SYNTAX HWBTSSAdslSeltCalibrationtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes calibration data of selt test. The index of this entry is ifIndex. " INDEX { ifIndex } ::= { hwBTSSAdslSeltCalibrationTable 1 } HWBTSSAdslSeltCalibrationtEntry ::= SEQUENCE { hwBTSSAdslSeltCalibrationInvVendorId OCTET STRING, hwBTSSAdslSeltCalibrationDataSegment1 OCTET STRING, hwBTSSAdslSeltCalibrationDataSegment2 OCTET STRING } -- 1.3.6.1.4.1.2011.6.21.3.1.1.26.1.1 hwBTSSAdslSeltCalibrationInvVendorId OBJECT-TYPE SYNTAX OCTET STRING (SIZE(8)) MAX-ACCESS read-only STATUS current DESCRIPTION "It consists of 8 binary octets, including a provider code. " ::= { hwBTSSAdslSeltCalibrationEntry 1 } hwBTSSAdslSeltCalibrationDataSegment1 OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..8192)) MAX-ACCESS read-only STATUS current DESCRIPTION "The part 1 of selt calibration data. The unit of selt calibration data is 0.00001. " ::= { hwBTSSAdslSeltCalibrationEntry 2 } hwBTSSAdslSeltCalibrationDataSegment2 OBJECT-TYPE SYNTAX OCTET STRING(SIZE(0..8192)) MAX-ACCESS read-only STATUS current DESCRIPTION "The part 2 of selt calibration data. The unit of selt calibration data is 0.00001. " ::= { hwBTSSAdslSeltCalibrationEntry 3 } hwBTestTraps OBJECT IDENTIFIER ::= { hwBTest 2 } hwBTestTrapVbOids OBJECT IDENTIFIER ::= { hwBTestTraps 1 } hwBTestVbOidsReason OBJECT IDENTIFIER ::= { hwBTestTrapVbOids 2 } hwBTSSCqtOfflineReason OBJECT-TYPE SYNTAX INTEGER { commFail(1), userReset(2) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "Cqt module offline reason. Options: 1. commFail(1) - CQT module communication fail. Resolving method:Check CQT module running normal 2. userReset(2) - User reset command " ::= { hwBTestVbOidsReason 1 } hwBTSSRequestID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "NMS request ID." ::= { hwBTestVbOidsReason 2 } hwBTestAlarmTraps OBJECT IDENTIFIER ::= { hwBTestTraps 2 } hwBTestAlarmTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestAlarmTraps 0 } hwBTSSCqtOnlineTrap NOTIFICATION-TYPE OBJECTS { ifIndex } STATUS current DESCRIPTION "CQT unit online status trap. This notification indicates alarm when CQT unit online. enumFirst: explain: CQT module communication OK resolving method:NA. " ::= { hwBTestAlarmTrapsOIDs 1 } hwBTSSCqtOfflineTrap NOTIFICATION-TYPE OBJECTS { ifIndex, hwBTSSCqtOfflineReason } STATUS current DESCRIPTION "CQT unit offline status trap. This notification indicates alarm when CQT unit offline. " ::= { hwBTestAlarmTrapsOIDs 2 } hwBTestGeneralTraps OBJECT IDENTIFIER ::= { hwBTestTraps 3 } hwBTestGeneralTrapsOIDs OBJECT IDENTIFIER ::= { hwBTestGeneralTraps 0 } hwBTSSCoStartTrap NOTIFICATION-TYPE OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult } STATUS current DESCRIPTION "Start Co test trap. This notification indicates alarm when starting Co test. " ::= { hwBTestGeneralTrapsOIDs 1 } hwBTSSCoStopTrap NOTIFICATION-TYPE OBJECTS { ifIndex, hwBTSSCoOperType, hwBTSSCoTestResult } STATUS current DESCRIPTION "Stop Co test trap. This notification indicates alarm when stopping Co test. " ::= { hwBTestGeneralTrapsOIDs 2 } hwBTSSTestedPortOperTrap NOTIFICATION-TYPE OBJECTS { ifIndex,hwBTSSTestedPortOperType,hwBTSSTestedPortOperMode,hwBTSSTestedPortOperResult } STATUS current DESCRIPTION "Tested port operation trap. This notification indicates alarm when tested port operation. " ::= { hwBTestGeneralTrapsOIDs 3 } hwBTSSCqtTransTestOperResultTrap NOTIFICATION-TYPE OBJECTS { ifIndex,hwBTSSCqtTransTestOperType,hwBTSSCqtTransTestOperResult } STATUS current DESCRIPTION "Cqt transparent test trap. This notification indicates alarm when starting or stoping Cqt transparent test. " ::= { hwBTestGeneralTrapsOIDs 4 } hwBTSSCqtTransTestResultTrap NOTIFICATION-TYPE OBJECTS { ifIndex,hwBTSSCqtTransTestResultLastFlag,hwBTSSCqtTransTestResultNo,hwBTSSCqtTransTestResult } STATUS current DESCRIPTION "Cqt transparent test trap. This notification indicates alarm when reporting the result after Cqt transparent test. " ::= { hwBTestGeneralTrapsOIDs 5 } hwBTSSLoopLineToneOperTrap NOTIFICATION-TYPE OBJECTS { hwBTSSLoopLineToneResult } STATUS current DESCRIPTION "loop line tone test result trap: 1:hwBTSSLoopLineToneResult. This notification indicates alarm when reporting the test result of Loop Line Tone. " ::= { hwBTestGeneralTrapsOIDs 6 } hwBTSSCaptureTrap NOTIFICATION-TYPE OBJECTS { hwBTSSRequestID, ifIndex, hwBTSSTestedPortOperType, hwBTSSTestedPortOperMode, hwBTSSTestedPortOperResult } STATUS current DESCRIPTION "BTSS capture trap. This trap is sent when BTSS capture result reported. " ::= { hwBTestGeneralTrapsOIDs 7 } hwBTSSDeltResultDataTrap NOTIFICATION-TYPE OBJECTS { hwBTSSAdslDeltTestResultNo, hwBTSSRequestID, ifIndex, hwBTSSAdslDeltTestResultLastFlag, hwBTSSAdslDeltTestResult } STATUS current DESCRIPTION "BTSS delt result trap. This notification indicates alarm when captures result data of BTSS delt test. " ::= { hwBTestGeneralTrapsOIDs 8 } END